Home

User Manual

image

Contents

1. 32 SHOWGUN User Manual CHAPTER 4 Fixture Programming Color Mixing The SHOWGUN fixture has two color mixing systems A CMY system that is comprised of a dichroic color mixing system for output from the Output Lens and a RGB color mixing system that is comprised of 36 RGB Modules in the LED Tracking system CMY Color The CMY color mixing system creates and infinite range of color by moving pairs of Cyan Magenta and Yellow flags Several color selection modes are available in either full speed controller crossfading the wheel positions or MSpeed MSpeed control of the wheel motor For more information on MSpeed see MSpeed Motor Speed on page 36 The Color Function you choose will effect which parameter values are available for each individual color Cyan Magenta and Yellow The following table describes the Color Functions available on the SHOWGUN fixture Continuous Allows exact positioning at any point on the color wheel Random Selects whole color positions at variable speeds Cycle Cycles through colors Tri Color single flag Controls movement of one flag of a pair with the other flag open Tri Color dual flag Controls movement of one flag of a pair with the other flag closed fully saturated Tri Color Independent control over individual flags in each color pair allows you to create tri color beam effects You can choose whether to control one or both flags of a pair SI NGLE FLAG MODE Flag 1
2. 2 Use the left and right arrows on the Center button to scroll to the TEST OPTIONS MENU and press the Enter button to select 3 Use the left and right arrows on the Center button to scroll to HOME FIXTURE 4 Press the Enter button to store the selection The fixture will begin homing SHOWGUN User Manual 25 CHAPTER 3 SHOWGUN Menu System Lamp State The LAMP STATE option in the TEST OPTIONS menu turns the lamp ON or OFF Copying the Boot Code When new software is uploaded to SHOWGUN fixtures it may contain a new boot code which must be copied to each fixture This is apparent if the fixture displays a BOOTDIFF error CAUTI ON Do not remove power from the fixture while performing a boot copy To accept and store the new boot code l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Using the left and right arrows on the Center button scroll to the TEST OPTIONS MENU and press the Enter button to select 3 Using the left and right arrows on the Center button scroll to the COPY BOOT option and press the Enter button to select 4 Use the up and down arrows on the Center button to scroll to the YES option and then press the Enter button to store the command The fixture will store the new boot code then automatically home Display Test Motor Setup This option is used when calibrating flag motors in Production Homing see Production Homing on page 47
3. Instructions pertaining to continued protection against fire electric shock and injury to persons are found in Important Safety Information on page 55 Please read all instructions prior to assembling mounting and operating this equipment Important Informations De S curit Les instructions se rapportant la protection permanente contre les incendies l lectrocution excessif et aux blessures corporelles se trouvent dans l Annexe C Veuillez lire toutes les instructions avant d assembler de monter ou d utiliser cet quipement Wichtige Sicherheitshinweise Sicherheitsanleitungen zum Schutz gegen Feuer elektrischen Schlag und Verletzung von Personen finden Sie in Anhang C Vor der Montage dem Zusammenbau und der Intbetriebnahme dieses Ger ts alle Anleitungen sorgf ltig durchlesen I nformazioni I mportanti Di Sicurezza Le istruzioni sulla protezione da incendi folgorazione e infortuni sono contenute nell appendice C Si prega di leggere tutte le istruzioni prima di assemblare montare e azionare l apparecchiatura Informacion I mportante De Seguridad En el Ap ndice C se encuentran instrucciones sobre protecci n continua contra incendios descarga el ctrica y lesiones personales Lea por favor todas las instrucciones antes del ensamblaje montaje y operaci n de este equipo iv SHOWGUN User Manual FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device
4. User Manual High End Systems Inc 2007 All Rights Reserved Information and specifications in this document are subject to change without notice High End Systems Inc assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Trademarks used in this text High End Systems WholeHog and Lithopatterns are registered trademarks and SHOWGUN Internal Effects the High End Systems globe logo Light Burst the Hog logo are trademarks of High End Systems Inc or High End Systems Europe Ltd Hog is a registered trademark of Flying Pig Systems Belden is a registered trademark of Belden Inc FastFit is a trademark and Philips is a registered trademark of Philips Lighting Company Krytox is a registered trademark of DuPont Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products High End Systems disclaims any proprietary interest in trademarks and trade names owned by others HIGH END SYSTEMS S SHOWGUN user Manual Version 80440131 1 1 Printed in the USA January 2998 SHOWGUNS User Manual Contacting High nd Systems U S and the Americas Sales Department Customer Service World Wide Web High End Systems Inc 2105 Gracy Farms Lane Austin TX 78758 USA voice 512 836 2242 fax 512 837 5290 Toll Free 800 890 8989 High End Systems Inc 2105 Gracy Farms Lane Austin TX 787
5. 16 6 10 28108 15 6 OF 23296 14 5 OE 29490 13 5 0D 23684 12 5 00 238 79 11 4 0 1240 75 10 4 OA 24272 9 4 3 08 24668 7 3 07 248 68 6 2 06 248 68 6 2 06 54 SHOWGUNS User Manual Appendix B Important Safety Information Warning For Continued Protection Against Fire l OO Ui A N This equipment is designed for use with specified lamps only Use of any other type lamp may be hazardous and may void the warranty Do not mount on a flammable surface Maintain minimum distance of 1 0 meter 3 feet from combustible materials Replace fuses only with the specified type and rating Observe minimum distance to lighted objects of 4 0 meter 13 feet This equipment for connection to branch circuit having a maximum overload protection of 20 A Warning For Continued Protection Against lectric Shock l If this equipment was received without a line cord plug attach the appropriate line cord plug according to the following code brown live blue neutral green yellow earth In the United Kingdom the colours of the cores in the mains lead of this equipment may not correspond with the coloured markings identifying the terminals in your plug proceed as follows the core which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green
6. ON Indicates or turns lamp on COPY BOOT NO Does nothing when selected Copies boot code to fixture FF DISPLAY TEST OFF Default Safe setting ON Performs Display test FF SETUP MOTORS OFF Default Safe setting ON Runs motor setup routine 7 OFF Leaves encoders enabled ENCODER TEST OFF Leaves encoders enabled ON Disables encoders CAL RGB LEDS Default Safe setting CODE MENU For factory use only SENSOR STATUS Displays absolute position of Pan MENU TILT Displays absolute position of Tilt UNIQUE NUMBER Displays fixture s unique 10 character THHHHHHHHHE number 18 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System Option Setting Description Notes DMX VALUES 1 44 HAF Displays current values for all channels in MENU 4 HH HH IHH groups of six DMX values screen After selecting CURRENT MAXIMUM or MINIMUM CURRENT you can view the temperature for the following sensors MAXIMUM TOPBOX C TEMPERATURES HEAD 1 C MENU MINIMUM LED TRACKING HHC Default setting is NO Select YES and press TEMP RESET Enter for 5 seconds to reset all sensors to Current Temperature FIXTURE HOURS Displays fixture operation time in hours minutes FIXTURE HOURS NO Default safe setting RESET YES Press Enter for 5 seconds to reset fixture hours to O LAMP HOURS Displays lamp operation time in hours minutes LAMP STRIKES Displays current number of lamp strikes LAMP HR STRIKE NO Default safe setting INFOMATION RESET 44
7. ncoder Disable Code Menu 26 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System Information Menu The Information menu displays current fixture information such as internal temperature lamp hours total fixture hours lamp strikes hardware and software versions DMX errors and view DMX data for any device on the link Lamp and Fixture hours resets are also executed in the Information Menu Sensor Status Menu The Sensor Status displays the current numeric position of the fixture s encoders To view encoder values l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select 3 Use the left and right arrows on the Center button to scroll to the SENSOR MENU and press the Enter button to select 4 Use the left and right arrows on the Center button to scroll to view PAN ENCODER or TILT ENCODER value Unique Number Each SHOWGUN fixture has a unique number similar to a serial number Use this option to view the fixture s unique number DMX Values Menu This menu option lets you view the current DMX value for every channel on the DMX link that includes this fixture To help you navigate through all the channels on the link the menu displays the values for Channels 001 512 in two lines of three DMX values you can scroll through using the up and down b
8. D d k Praia 16 Error Message DISD S V sarey a bayay ka banika ea k ka a a lu dadane W Wu d wal n karl 16 Unlocking the Menu System a unse ee 17 Exiting the Menu SVS SITI sense 17 Menu Map u een 18 Menu System OPUONS allea 20 OMX Address MENU un ee 20 Setting DMX Start Channel asus 20 Determining DMX Start Channel Assignment nenn nenn 20 Set Parameters Menu sera axe adnexa en 22 Factory Default Settings eem emen nnns 22 Pan ME SW 22 PAD ae E E E io 23 didi ne 23 Lao Lie EI PEE 24 Data A e ner E NEUEE kaw EIE 24 Fixture eas m 25 Crossloading Fixture Software ee nani LR an 25 Test OP ONS MER ella are 25 FHom ino sa FIXTE Ame AAPP LETS 25 SAR a REL eee Te RER ten TERN 26 Copying The Boot COUR ariba 26 BIA I 26 Motor SETUD FT 26 Encoder Disa ble qm 26 OS SU a ia dun ue 26 BRF FEER MENU 27 li SHOWGUN User Manual Sensor Status Menu SEE A eat eee 27 UNIQUE Num DE sea ee idibus iaia 27 DMX Values MENU T ee ee 27 Temperatures Menu nun ENKEN nnn nhanh aa aaa aaa a anne re kk kk kk ak kaka nn 28 FREE FOLKS NI ET H HH HHH HEHEHEHHHHDHDHDMDMHMTMDMME 28 Fixture Hours Reset ii rr 29 FAND OR aa are 29 Lam SERES MES UTI 29 Lamp HR SEFIKE e khan kanala
9. a O O O Fagz O O 00 9 O 0 gt 127 128 gt 254 255 50 100 DUAL FLAG MODE al CO O O Flag 2 Y O ID O SHOWGUN User Manual 33 CHAPTER 4 Fixture Programming RGB Color The LED Tracking System uses Red Green and Blue LEDs RGB to produce a color spectrum you can control and dim independently from the main output beam There are 36 RGB LED modules that make up the LED Tracking System Each RGB Module consists of a homogenizing lens and an RGB die LED Tracking System The LED Tracking System uses 3 watt LEDs that can produce close to 5000 lumens of light and can be used along with or independent from the main output The LED Tracking System allows you to select an LED color that matches the color from the main output beam or tracks with a complementary color LED Tracking Functions The LED Tracking System is capable of strobing and other effects independent from those applied to the main output beam Allows exact intensity control of each LED color Selects whole colors at variable speeds Cycles through colors Periodic Strobe Strobes LEDs at specified intervals LED Tracking System Dimming Most automated luminaires have a single intensity system In addition to the main output intensity the SHOWGUN provides an additional intensity system for the LED Tracking System It operates in two modes Dim Tracking Mode In this mode the LED Tracking System dims as the m
10. construction Electronic cooling system control Exterior design prevents stray light scatter Pan and tilt locks for easy transportation e Custom SHOWGUN roadcase provided 2 SHOWGUN User Manual CHAPTER 1 Product Overview Related Products and Accessories The following table lists other products you can utilize with the SHOWGUN fixture and optional accessories available from your High End Systems dealer distributor Heavy duty 5 pin XLR cable 25 55050018 Heavy duty 5 pin XLR cable 507 55050019 Heavy duty 5 pin XLR cable 100 55050020 For more information about optional accessories contact either your High End Systems dealer distributor High End Systems Sales or visit the High End Systems Web site For contact information see Contacting High End Systems on page ii SHOWGUN User Manual 3 CHAPTER 1 Product Overview Specifications Mechanical Fixture Dimensions 596mm x 639mm x 959mm 23 5in x 25 2in x 37 8in Road Case Dimensions 749mm x 1200mm x 724mm 29 5in x 47 25in x 28 5in Fixture Weight 63 5kg 140 Ib Shipping Weight Roadcase fixture 118 kg 260 Ib 639 mm 25 2 in 363 mm 14 3 in pull NDOMONS E 469 mm 18 5 in 596 mm 29 9 in 4 SHOWGUN User Manual CHAPTER 1 Product Overview Operational Pan 420 Tilt 216 Zoom Range 9 18 Fixture Output 100 000 Lumens nvironmental Maximum ambient temperature T4 45
11. control of all other parameters in the scene The amplitude of the position macro movement is determined by the Pan Coarse channel and Tilt Coarse channel respectively The MSpeed channel controls the speed of the macros With the MSpeed set at the default value of DMX 0 4 an Internal Effects macro completes its movement in approximately 2 5 seconds This provides a pleasing look when the additional variation given by using the MSpeed channel is not required With the MSpeed set between DMX 5 255 nternal Effects macros complete movement at the selected MSpeed time up to 25 seconds 36 SHOWGUN User Manual CHAPTER 4 Fixture Programming Control Settings The Control parameter activates certain Fixture functions To access all SHOWGUN Control settings except for Pan amp Tilt MSpeed Off first select a control channel value then set the Shutter channel to 0 NOTE The Control channel should not be crossfaded Home Lamp Off Remotely extinguishes the fixture s lamp Shutdown Remotely deactivates the fixture When a fixture is shut down the lamp is extinguished power to the motors is disabled and the LED display reads SHUT DOWN If a fixture is in shutdown mode you must home the fixture to bring it back into operation Outrig Mode Insures uninterrupted movement of pan and tilt for fixtures side mounted or in acute angular positions Note Because this is a DMX mode it will not persist in the fixture S
12. cord cap for your location Because of the variety of power cord caps used worldwide High End Systems Inc cannot make specific recommendations for the power cord cap Contact a local authority for the type of power cord cap needed When installing the power cord cap note that the cores in the mains lead are colored according to the following code green and yellow earth blue neutral brown live SHOWGUNS User Manual 7 CHAPTER 2 oetup and Configuration Installing a Line Cord Cap U K Only In the United Kingdom core colours in the mains lead of this equipment may not correspond with the colored markings identifying the terminals in the fixture s plug In that case install a line cord cap in accordance with the following code Connect the green and yellow core to the plug terminal marked with the letter E or by the earth symbol amp or coloured green or green and yellow e Connect the blue core to the terminal marked with the letter N or coloured black e Connect the brown core to the terminal marked with the letter L or coloured red WARNI NG Class 1 equipment This equipment must be earthed Vatic Fitter Heads Information Danmark Advarsel Beskyttelse mod elektrisk chock Vigtigt EN Lederne med gul groen isolation maa kun tilsluttes en klemme maerket a Euer Mounting the Fixture You can mount your SHOWGUN fixture suspended from a support system such as a truss or freestandin
13. disconnect power to the fixture If it has been operating allow the fixture to cool for five minutes before handling Do not use C Clamps to mount the SHOWGUN fixture to truss AN Use the following steps to mount a SHOWGUN fixture on a standard truss 1 Due to its size and weight at least two people should support the fixture while another attaches clamps and safety cables Always stand on a firm stable surface when mounting the fixture to its support 2 Tighten the clamps firmly to the fixture s base and to the truss 3 Run the safety cable through the loop on the fixture s base and around the truss Side Mounting and Angular Mount by Moving Truss When side mounting a SHOWGUN fixture orient the unit as show on the right with the Display panel ji I OM up or down perpendicular to the floor For fixtures in a side mount or at an acute Angular orientation set the Outrig Mode on the DMX console see Control Settings on page 37 SHOWGUN User Manual 9 CHAPTER 2 oetup and Configuration Linking SHOWGUN Fixtures SHOWGUN fixtures operate on standard DMX512 link controlled by a DMX console The number of fixtures on a link will be determined by the combined number of channels required by all the fixtures A SHOWGUN fixture requires 30 channels on a standard DMX512 link Attach the fixture to the link using data grade cable and 5 pin XLR cable connectors Cable Connectors The SHOWGU
14. fixtures Fixture DMX location Fixture channels EE Channel on the type used per link fixture Channel First SHOWGUN 30 channels C001 1 30 The Start channel is the number of the first channel in a consecutive block of channels assigned to a fixture Third SHOWGUN 30 channels C031 31 60 Fixture can be assigned the second block of DMX channels without physi cally being the second fixture on the link Second HOWGUN 30 channels C069 69 98 To avoid overlapping channels place the start channel at the beginning of a range of available channels large enough to accommodate that fixture type Fourth Studio Spot 18 channels C121 121 138 Every channel in the link does not need to be assigned When setting the Start channel on a fixture remember A fixture s physical location on the link does not have to coincide with the order of channel range assignments in the link See Row 2 in the above table The fixture s channel range must not overlap any other device s channel range on the link When two devices on the same DMX link have overlapping channel ranges one or both devices will be disabled or behave erratically The single exception would be if two or more fixtures need to respond to controller commands in exactly the same way In that case those fixtures must be the same type for example two SHOWGUN fixtures and must share the entire channel range SHOWGUN User Manual 21 CHAPTER 3 SHOWGUN Menu
15. or green and yellow the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black the core which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red 3 Class equipment This equipment must be earthed 4 5 6 Equipment suitable for dry locations only Do not expose this equipment to rain or moisture Disconnect power before re lamping or servicing Refer servicing to qualified personnel no user serviceable parts inside Warning For Continued Protection Against xposure To xcessive Ultraviolet UV Radiation 1 2 Change shields and lenses if they have become visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches Never look directly at the lamp while lamp is on SHOWGUN User Manual 55 Appendix B Important Safety Information Warning For Continued Protection Against Injury To Persons 1 Use secondary safety cable when mounting this fixture 2 Caution Hot lamp may be an explosion hazard Do not open for 5 minutes after switching off Wear eye and hand protection when re lamping 3 Equipment surfaces may reach temperatures up to 160 C 320 F Allow a minimum of 10 minutes for cooling before handling 4 Change the lamp if it becomes damaged or thermally deformed 56 SHOWGUN User Manual Appendix B Important Safety Inform
16. the fixture Replace with a PHILIPS MSR Gold SA SE only HES part 55030084 3 Usethe three Phillips head screws for lamp optimization SHOWGUN User Manual 41 CHAPTER 5 Maintenance and Troubleshooting Driver Boards The SHOWGUN fixture is designed with two basic types of motor driver boards A driver board is interchangeable with other boards of its type Standoffs and contact screws allow for position specific board addressing The fixture will not function correctly if contact screws are missing from driver boards e Phase Boards Four 2 phase boards control the motors for all CMY color flags Soft Edge Flags Gobo Indexing and Rotation as well as Zoom Focus and lris functions These boards are located together on a bracket inside the electronics housing behind the display panel Boards 1 and 2 are on the front side of the bracket Boards 4 and 8 are on the backside O a aA 4 DOO L 10 ja M Cyan2 Ri Board 2 M2 Magenta 2 M3 Yellow 1 M4 Yellow 2 94 5V Status LED Board 4 M1 Soft Edge 1 M2 Soft Edge 2 MB Gobo T7 M4 Gobo Rotate 93 Gobo Sense S4 Gobo Rotate Sense Board 8 I e el M1 Focus 1 09 N op C2 IN 1 ZN RF eu 1 pl 2 2 E 60 Ol N r ZW r EN r 42 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting 3 Phase Board Two 3 phase boards
17. the menu system or to move back up the system to the top level menus 2 Using the left and right arrows on the Center button scroll through the top level to SET PARAMETERS MENU and press the Enter button to select 3 Using the left and right arrows on the Center button scroll to TILT INVERT The current state ENABLED or DISABLED will be displayed 4 Use the up and down arrows on the Center button to scroll to ENABLED to invert Tilt movement or DISABLED to revert fixture to default setting and press the Enter button to select SHOWGUN User Manual 23 CHAPTER 3 SHOWGUN Menu System Lamp Life Limit Use this menu option to display the warning message Lamp Life Error when the current lamp hours reach the rated lamp life When the LAMP LIFE LIMIT parameter is enabled the fixture tracks the number of hours the lamp is on At 650 hours it displays an error message At 710 hrs the lamp shuts off and the fixture will not strike until the lamp is replaced and the lamp hours are reset to 0 See Replacing the Lamp on page 40 and Lamp HR Strike Reset on page 29 To enable the LAMP LIFE LIMIT parameter l Press the Menu button to unlock the menu system or to move back up the system to the top level menus Using the left and right arrows on the Center button scroll through the top level to SET PARAMETERS MENU and press the Enter button to select Using the left and right arrows on the Center button scroll to L
18. 03 EP 0969247 EP 1447702 ES 0621495 FR 0621495 FR 0655144 FR 0662275 FR 1447702 GB 2043769B GB 2055842B GB 2283808B GB 2290134B GB 2291814B GB 2292530B GB 2292896B GB 2294909B GB 2295058B GB 2303203B GB 2306887B GB 2307036B GB 2316477B IE 0621495 IT 034244BE 2005 IT 0621495 IT 0655144 JP 3495373 JP 3793577 NL 0621495 NL 0797503 NL 0969247 UK 0621495 UK 0655144 UK 0662275 UK 0797503 UK 0969247 UK 1447702 SHOWGUN User Manual vii viii SHOWGUN User Manual Table of Contents USER A een i Contacting High End Systems RS ii Declaration of Conformity ann A AA iii Product Modification Warning ss IV Important Safety Information issus IV PCC laedi riluttante o V ios q Re V Warranty INTO MALON TS T T oU it vi Limited Warran NETT TTE TOTO EDT vi Returning an Item Under Warranty for Repair vi gs Lele lana ha eel o vi p e e vi Chapter 1 Product Overview SHOWGUN Features nenne a ee 1 PRU S str rr aii A ria iia 1 O een era 2 COS CO TR m 2 Related Products and Accessories L 00 3 SPECIAL ION ee ee bg 4 Mechanical usada een 4 Operational a oca 5 EI VIS OMI n ee a ee 5 la ieigis e 5 RPOVel C ae 5 F SES c X 5 bamp SUC
19. 4 Soft Edge 2 Gobo Gobo Rotate Gobo Sense Gobo Rotate Sense Shutter Cyan 2 phase board Address 1 Shutter 1 Shutter 2 Cyan Flag 1 Cyan Flag 2 Magenta Yellow 2 phase board Address 1 Magenta Flag 1 Magenta Flag 2 Yellow Flag 1 Yellow Flag 2 5V Status LED Display 50 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting Board L D States The CPU 2 phase 3 phase LED Control and Data Communication boards are mounted for easy access on the bracket located behing the display panel on the electronics housing LEDs located on the boards help you troubleshoot the unit Location LED State Problem Deser ption 51 54 sensor open 51 54 sensor close Flashing red Board is initializing LD1 LD4 Infinitely da flashing red Board not receiving data Redo Y Board not receiving data Flashing red and Y Addressing screw s missing from es green board Sporadically 2 boards are addressed the same flashing green Yes Corrected by adding addressing amp yellow screw to appropriate location 2 phase board OFF Board not receiving power es Green No Receiving proper voltage L Dim green es Board not receiving data OFF Yes Board not receiving power Green Board receiving proper voltage Dim green Board not receiving data OFF Board not receiving power L HD6 sensor open 3 phase Green board L Flashing red OFF L HD6 sensor closed Green Flashing red D5 D1 D2 Board not receiv
20. 58 USA voice 800 890 8989 fax 512 834 9195 toll free 800 890 8989 http www highend com SHOWGUN User Manual Declaration of Conformitu according to I SO I EC Guide 22 and EN45104 Manufacturer s name High End Systems Inc Manufacturer s address 2105 Gracy Farms Lane Austin Texas 78758 USA Distributor s name High End Systems Inc Distributor s address 2105 Gracy Farms Lane Austin Texas 78758 USA Declares that the product Product Name SHOWGUN Product Number All Product Options All conforms to the following EEC directives 73 23 EEC as amended by 93 68 EEC 89 336 EEC as amended by 92 31 EEC and 93 68 EEC Equipment referred to in this declaration of conformity was first manufactured in compliance with the following standards in 2005 Safety EN 60598 1 1997 EN 60598 2 17 1990 A1 A3 1998 A13 1999 EMC EN 55022 Conducted Emissions Class A Radiated Emissions Class A ANSI C63 4 Class A FCC 47 CFR Part 15 Class A VCCI V 1 2001 04 Class A EN 55024 EN 61000 4 2 4 8kV EN 61000 4 3 A1 3V m EN 61000 4 4 1kV 0 5kV EN 61000 4 5 2kV 1kV EN 61000 4 6 3 Vrms EN 61000 4 11 gt 95 0 5p 30 25p gt 95 250p EN 61000 3 2 Class A EN 61000 3 3 USA Wednesday January 23 2008 Kenneth Stuart Hansen Compliance Engineer SHOWGUN User Manual iii Product Modification Warning High End Systems products are designed and manufactured to meet the requirements of United States and Intern
21. 6 421 165 US 6 430 934 US 6 459 217 US 6 466 357 US 6 502 961 US 6 515 435 US 6 523 353 US 6 536 922 US 6 538 797 US 6 545 586 US 6 549 324 US 6 549 326 US 6 563 520 US 6 565 941 US 6 570 348 US 6 575 577 US 6 578 991 US 6 588 944 US 6 592 480 US 6 597 132 US 6 600 270 US 6 601 974 US 6 605 907 US 6 617 792 US 6 621 239 US 6 622 053 US 6 635 999 US 6 648 286 US 6 664 745 US 6 682 031 US 6 693 392 US 6 696 101 US 6 719 433 US 6 736 528 US 6 771 411 US 6 775 991 US 6 783 251 US 6 801 353 US 6 812 653 US 6 823 119 US 6 865 008 US 6 866 390 US 6 866 402 US 6 866 451 US 6 869 193 US 6 891 656 US 6 894 443 US 6 919 916 US 6 930 456 US 6 934 071 US 6 937 338 US 6 955 435 US 6 969 960 US 6 971 764 US 6 982 529 US 6 988 805 US 6 988 807 US 6 988 817 US 7 000 417 US 7 011 429 US 7 018 047 US 7 020 370 US 7 033 028 US 7 048 838 US 7 055 963 US 7 055 964 US 7 057 797 US 7 073 910 US 7 078 869 US 7 092 098 US 7 119 902 US 7 161 562 US 7 175 317 US 7 181 112 US 7 206 023 US 7 210 798 US D347 113 US D350 408 US D359 574 US D360 404 US D365 165 US D366 712 US D370 080 US D372 550 US D374 439 US D377 338 US D381 740 US D409 771 AT E169413 CA 2142619 CA 2145508 CA 2245842 DE 22588 4 08 DE 621495 DE 655144 DE 69320175 4 DE 69322401 0 DE 69331145 2 DE 69525856 7 DE 69734744 3 DE 797503 DK 0655144 DK 1447702 EP 0475082 EP 0621495 EP 0655144 EP 0662275 EP 0767398 EP 07975
22. 8 F9 047 246 96 F6 055 245 96 F5 244 F4 E E E E E 266 230 90 ES 286 229 90 ES 307 208 89 E4 329 227 89 Es 352 226 89 E2 E 478 221 87 DD 506 220 86 DC DB F E D C B A 9 8 7 6 E E E D9 625 216 85 D8 689 214 84 D6 900 208 82 10 17 205 80 CD 7 78 C7 78 C6 77 C5 1979 185 78 B9 7 B3 2454 177 69 Bt Bo 2580 175 69 AF 2645 174 68 AE 2710 178 68 AD 2980 169 66 A9 3049 168 66 A8 3865 157 62 9D 4028 155 61 9B 4104 154 60 SA 4185 158 60 99 4268 152 60 98 4434 150 59 96 4519 149 58 95 4604 148 58 94 4690 147 58 93 91 4954 144 56 90 8 8 8 3 5 5 5 5 5 5 2 5 SHOWGUN User Manual 53 Appendix A MSpeed Conversion Table 5224 141 55 8D 5596 137 54 89 5884 134 58 86 6480 128 50 80 8559 109 48 6D 8795 107 42 6B_ 9034 105 41 69 91 55 104 41 68 9398 102 40 66 9770 99 39 68 9895 98 38 62 10149 96 38 60 109 28 90 35 5A 110 61 89 35 59 56 12291 80 31 50 13882 69 27 45 14082 68 27 447 LIN NE SES LM a0 182 01 16 2A gem d o m 185 44 21404 24 9 18 215 90 28 9 17 21776 22 9 16 21968 21 8 15 221511 20 8 14 229 11
23. AMP LIFE LIMIT Using the up and down arrows on the Center button choose the ENABLE option and press Enter to select Data Loss Timeout Use this menu option to determine how the fixture will react in the event of DMX data loss Set the shutter to stay open until shutdown or to close one second after data loss To set the DATA LOSS TIMEOUT l Press the Menu button to unlock the menu system or to move back up the system to the top level menus Using the left and right arrows on the Center button scroll through the top level to SET PARAMETERS MENU and press the Enter button to select Using the left and right arrows on the Center button scroll to DATA LOSS TIMEOUT Using the up and down arrows on the Center button choose LONG to keep the shutter open until shutdown or SHORT to close the shutter 1 second after data loss and press the Enter button to select 24 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System Fixture Mode Menu The Mode menu crossloads software from one fixture to other SHOWGUN fixtures on the link Crossloading fixture Software A fixture running a newer software version can load the new software to all other SHOWGUN fixtures on the link using the CROSSLOAD FIRMWARE menu option To CROSSLOAD FIRMWARE from one fixture to all SHOWGUN fixtures on the link l Disconnect or bypass any controllers serial data distributors data line optoisolators and any fixtures using RS 422 com
24. C 113 F Minimum Distance to Flammable Objects 4m 13 1 ft Maximum exterior surface temperature 150 C 302 F Minimum Focus Distance to non flammable object 3 m 10 ft Electrical Power Input Rating 200 240 VAC Fixture Rated Power 2800 W Power Consumption 14 Amps at 208 V 11 Amps at 240V WARNING Class 1 equipment This equipment must be earthed Fuses Motor Power Supply Input 2 5A 250V Slow Blow Littelfuse 90403027EF Motor Power Supply Output 5A 250V Slow Blow Littelfuse 90403012EF 2 phase Driver Boards i 2 5A 125V Slow Blow SMF Littelfuse 90402016EF 3 phase Pan and Tilt Board LED Control Board 5A 125V Slow Blow SMF Littelfuse 90412027EF Lamp Power Supply Input 20A 250V Very Fast 90403030EF SHOWGUN User Manual 5 CHAPTER 1 Product Overview Lamp Specifications Lamp PHILIPS MSR Gold SA SE Color Temperature 6000K Lamp Life 50 750 hrs CRI gt 30 CI E X 320 Y 330 Cable and Connector Specifications DMX data cables Belden 9841 or equivalent meets specifications for EIA RS 485 applications with the following characteristics e2 conductor twisted pair plus a shield emaximum capacitance between conductors 30 pF ft emaximum capacitance between conductor and shield 55 pF ft maximum resistance of 20Q 1000 ft nominal impedance 100 1400 DMX data connectors 5 pin male and female XLR connectors DMX data terminators Male XLR connector with 120 ohm ter
25. CINCAUIONS suecas lato i Um 6 Cable and Connector Specifications kk kk kk kk kk eee esses kk kk ka kaka kaka aka ak kk kk 6 Lit Patteri SPEEINICAUONIS i xy xsxeyldl lxxra t AAA na denses 6 Chapter 2 Setup and Configuration Unpacking the FIXEURE SSSR wen nAA vk en ae 7 Installing a Power Cord Cap aus a 7 Installing a Line Cord Cap U K Only kk kk kk kk kk kk kk 8 Vatic Fitter Heads Information Danmark 8 Mounting the Fixture rr 8 Mounting the Fixture Upright iii emen 9 Truss Jd al aeweeo r hp bb er 9 Side Mounting and Angular Mount by Moving Truss kk kk n 9 SHOWGUNS User Manual LINKING SHOVVIGUN FEIXEMEBS een asta pesa icona 10 Sera a M c P 10 Conhectihng to the LINK serien 11 Powering OR ENS SERRES E D DS UIT 11 DD AR DT GS HOMINO eM ee een EA 11 Setting the DMX Start Channel i 4444 xu yadan danan y k kk ya ya l wa xalk an xala nal an hak ya ray Ala KANA 12 Determining DMX Start Channel Assignment k 12 Shutting DOWN the FIXEUTE rain 13 Chapter 3 SHOWGUN Menu System Navigating the Menu System seen ness risa an aaa ann nnn 15 The SHOWGUNTS DIS DIN a mern 15 Navigational BASIC einen a alayan lae ar ne aa nee doses 16 Display in Menu Locked Mode US 16 Fixture Software Version kk ERE rra kaka kak hene sa ka kk ka kk kk kk kk ka 16 DMX Start Channel x a 0 kaka ak kil xod eadein REPRE
26. DMX Data cable to the controller s DMX Data Out connector 2 Connect the Data cable s female XLR connector to the Data In connector of the first or next fixture on the DMX link 3 Continue linking the remaining fixtures connecting a cable from the Data Out connector of each fixture to the Data In connector of the next fixture on the link 4 Terminate the link by installing a 120 ohm 1 4 watt minimum terminator in the fixture s Data Out female cable connector in the last fixture on each DMX link A terminator on the last fixture of the link prevents data reflection which can corrupt the data communication on the link To construct a terminator l Disassemble a male 5 pin XLR connector 2 Solder a 120 ohm resistor minimum of 1 4 watt between Pin 2 and P 3 Reassemble the XLR connector Powering On the Fixture WARNING This equipment is designed for connection to a branch circuit having a maximum overload protection of 20 A Do not power on the fixture until verifying that the line cord cap is suitable for the power source in your location For more information see Installing a Power Cord Cap on page 7 AN To power on the SHOWGUN fixture simply connect it to a 200V 240V AC power source Fixture Homing Once the SHOWGUN fixture is connected to a power source it automatically begins a homing procedure to verify that the major functions of the fixture SHOWGUN User Manual 11 CHAPTER 2 oetup and Conf
27. Four fully rotating indexable lithopattern gobos Blacklight projection filter Variable iris Variable strobe Electronic strobe e Light Burst lamp boosting Remote focus Full optical dimming and fade to black e Smooth CMY color mixing provides and infinite palette of color Tracking and Independent modes selectable via DMX SHOWGUN User Manual 1 CHAPTER 1 Product Overview Independent color flag control supports TriColor effects LED Tracking Ring produces over 5000 lumens of RGB color e Homogeneously mixed RGB LED circular array eliminates the multiple colored RGB look when white or mixed colors are produced Optical encoders automatically correct the head s position if manually moved Operation 420 Pan 216 Tilt High resolution DMX512 programming control Fat output beam 10 in 250 mm diameter e Shutter construct parameters including ramp snap and synchronous strobing functions Fully dichroic colors that never fade LED status indicators streamline troubleshooting Large dot matrix display that allows for 2 lines of text e 5 pin XLR connectors Precision stepper motors control dimmer shutter function and color mixing Interchangeable 2 and 3 phase driver boards are easily accessible simplify servicing Construction Fast smooth and quiet yoke movement using proprietary multi phase technology Fast service design for Reflector Condenser and Output lens Modular
28. H YES Press Enter for 5 seconds to reset fixture MENU hours to O LAMP OFF LAMP ON Displays current lamp ua LAMP STRIKING status LAMP ERROR SOFTWARE VERSION VEE Major Minor Build PAN HW SW TILT HW SW SHUTTER CYAN HW SW Displays the Hardware and Software MAG YELLOW versions for each logic board in the fixture MODULE VERSION HW SW MENU EDGE GOBO ROT HW SW FOCUS ZOOM IRIS HW SW RGB LED CONTROL HW SW DISPLAY Displays NOT AVAILABLE if a board does not NOT AVAILABLE exist in that position SHOWGUN User Manual 19 CHAPTER 3 SHOWGUN Menu System Option Setting Description Notes DISPLAY ERRORS XXXXXXXXXXXXX Scrolls through errors displayed in 2 line MENU XXXXXXXXXXXXX 16 character format INFOMATION CHANNELS Displays channel range for current MENU NEEDED configuration 30 for SHOWGUN fixtures NEXT DMX Current start channel channels CHANNEL ii Menu System Options The following sections describe and give examples for selecting and or setting available menu options DMX Address Menu DMX Address is the top level menu selection used to set the fixture s DMX start channel Use this menu option to change the existing DMX start channel to another DMX start channel Setting DMX Start Channel To set the DMX start channel 1 Press the Menu button to unlock the menu system or to move back up the system to the top level menus DMX ADDRESS MENU is the fir
29. Manual CHAPTER 3 SHOWGUN Menu System Fixture Hours Reset Use this option to reset the fixture operation time to Zero To access the FIXTURE HOURS RESET option l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select 3 Use the left and right arrows on the Center button to scroll to the FIXTURE HOURS RESET option and press the Enter button to select 4 Use the up and down arrows on the Center button to scroll to YES Press and hold the Enter button down for 5 seconds to select Lamp Hours Use this option to view the lamp operation time in hours and minutes Lamp Strikes Use this option to view the total number of lamp strikes Lamp HR Strike Reset After installing a new lamp the Lamp hours and Lamp strike sensors must be reset to O before the Lamp will strike To access the LAMP HR STRIKE RESET option l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select 3 Use the left and right arrows on the Center button to scroll to the LAMP HR STRIKE RESET option and press the Enter button to select 4 Use the up and down arrows on the Center button to scroll to YES Press and hold t
30. N fixture accepts 5 pin XLR cable connectors Cabling must have a male XLR connector on one end of the cable and a female XLR connector on the other end Pin one is the common cable shield pin two is the data complement negative pin three is the data true positive Pins four and five are not used but they allow a secondary data link to pass through the fixture Grounding lug inside XLR shell pL ie Common En j i cable shield 5 2 E i 1 C lt 2 positive positive fees o P Ay A st Common data negative negative o ET LEN complement data complement data Li ositive p l complement positive complement data true data true Male XLR Connector Female XLR Connector This data line is not used by the fixture but allows data to pass through the fixture Test each cable with a voltage ohm meter VOM to verify correct polarity and to make sure that the negative and positive pins are not grounded or shorted to the shield or to each other CAUTI ON N Do not connect anything to the ground lug on the XLR connectors Do not connect or allow contact between the common cable shield and the fixture s chassis ground Grounding the common could cause a ground loop and or erratic behavior 10 SHOWGUN User Manual CHAPTER 2 oetup and Configuration Connecting to the Link To link one or more fixtures to a DMX controller l Connect the male XLR connector of a
31. System Set Parameters Menu The Set Parameters menu sets all factory options to their default settings or changes the factory options individually Factory Default Settings A SHOWGUN fixture ships with the following factory default settings Pan Tilt Swap DISABLED Tilt Invert DISABLED Lamp Life Limit DISABLED Pan Invert DISABLED Display Level 0N Data Loss Timeout SHORT If any of the default settings are changed this menu reverts to the OFF option The ON option restores all factory defaults To check and reset factory defaults l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Using the left and right arrows on the Center button scroll through the top level to SET PARAMETERS MENU and press the Enter button to select 3 Using the left and right arrows on the Center button scroll to FACTORY DEFAULT SETTINGS The current state ON or OFF will be displayed 4 To reinstate the factory defaults if OFF is displayed use the up and down arrows on the Center button to scroll to ON and press the Enter button to select Pan Tilt Swap This option swaps the pan motor and tilt motor operation to coordinate movements between fixtures on a link mounted perpendicular to each other To swap Pan and Tilt l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Using the left and right arrows on the Center button scroll through
32. Up and Down arrow buttons on the Center button to select a new DMX start channel The display will flash a new option ready for selection Note The last valid Start channel for a SHOWGUN fixture is based on its 30 channel range The last valid start channel for a SHOWGUN fixture is 483 512 304 1 5 Press the Enter button to store the new DMX Start channel The display will stop flashing when a new option is entered Determining DMX Start Channel Assignment There are 512 available channels on each DMX link divided among all the devices in a particular link A fixture must have a unique Start channel number in order to respond independently to controller commands To determine each fixture s DMX start channel in a link identify the channel range of every fixture on the link Channel range is the number of consecutive channels a fixture requires Each 12 SHOWGUN User Manual CHAPTER 2 oetup and Configuration SHOWGUN fixture requires a block of 30 consecutive channels on a 512 Channel DMX link The Start channel is the first number of a fixture s channel range The notes in the following table show the various considerations in determining valid Start Channels for fixtures on a 512 DMX link A single 512 Channel DMX link can accommodate up to sixteen 30 channel SHOWGUN fixtures Fixture DMX location Fixture channels az Channel on the type used per link fixture Channel First SHOWGUN 30 channels C001 1 30 The Start channe
33. ain output dims When the Output Dim channel is set at a lower intensity it will override the LED Tracking Dim channel Visually the lowest level takes precedence This ensures that both intensity systems black out when the main output blacks out for example when using the console s Grand Master NOTE You can view LEDs alone in the tracking mode if you close the lamp shutter Tracking System Independent Dim Mode In this mode the Dim parameter operates independently from the LED Tracking Dim Parameter allowing separate control over output dimming and LED dimming NOTE This mode may result in SHOWGUN fixtures outputting LED intensity when the console Grand Master is at zero 34 SHOWGUN User Manual CHAPTER 4 Fixture Programming Shutter and Lamp Effects The Shutter Lamp Function channel determines how the Shutter channel will function When you select one of the following options in the Shutter Lamp Function channel the Shutter channel sets the strobe rate from slow to fast Shutter Lamp Function Shutter Channel Closes shutter Normal Shutter Functions Strobes beam at specified intervals from slow to fast Random Strobe Allows all SHOWGUN Fixtures on the DMX link to strobe their shutters at random times from slow to fast Random Synchronous Allows all SHOWGUN Fixtures on the DMX link to strobe their shutters Strobe at random times in unison from slow to fast Lamp Functions see next table When you select the Lamp F
34. ation Appendice C Importantes Informations Sur La S curit Mise n Garde Pour Une Protection Permanente Contre Les Incendies l Oo Ul RP WU N Cet appareil est concu pour l usage avec les lampes sp cifi es seulement Son utilisation avec tout autre type de lampe peut tre dangereuse et annuler la garantie Ne pas monter les lampes sur une surface inflammable Maintenir une distance minimum de 1 0 m tre de mati res inflammables Ne remplacer les fusibles qu avec des modeles et valeurs assign es recommand s Respecter une distance minimum de 4 0 m tre par rapport aux objets clair s Cet appareil de connection au circuit comporte une protection contre les surcharges de 20 A Mise En Garde Pour Une Protection Permanente Contre Les Chocs lectriques Il 5 Si cet quipement est livr sans prise de cable veuillez connecter la prise de cable correcte selon le code suivant marron phase bleu neutre vert jaune terre D brancher le courant avant de changer les lampes ou d effectuer des r parations Cet quipement doit tre uniquement utilis dans des endroits secs Ne pas l exposer la pluie ou l humidit l int rieur de l quipement il n y a pas de pi ces remplacables par l utilisateur Confiez l entretien un personnel qualifi Equipement de Classe Cet quipement doit tre mis la terre Mise En Garde Pour Une Protection Permanente Contre Des E
35. ational safety regulations Modifications to the product could affect safety and render the product non compliant to relevant safety standards Mise En Garde Contre La Modification Du Produit Les produits High End Systems sont concus et fabriqu s conform ment aux exigences des r glements internationaux de s curit Toute modification du produit peut entrainer sa non conformit aux normes de s curit en vigueur Produktmodifikationswarnung Design und Herstellung von High End Systems entsprechen den Anforderungen der U S Amerikanischen und internationalen Sicherheitsvorschriften Ab nderungen dieses Produktes k nnen dessen Sicherheit beeintr chtigen und unter Umst nden gegen die diesbez glichen Sicherheitsnormen versto en Avvertenza Sulla Modifica Del Prodotto prodotti di High End Systems sono stati progettati e fabbricati per soddisfare i requisiti delle normative di sicurezza statunitensi ed internazionali Qualsiasi modifica al prodotto potrebbe pregiudicare la sicurezza e rendere il prodotto non conforme agli standard di sicurezza pertinenti Advertencia De Modificaci n Del Producto Los productos de High End Systems est n dise ados y fabricados para cumplir los requisitos de las reglamentaciones de seguridad de los Estados Unidos e internacionales Las modificaciones al producto podr an afectar la seguridad y dejar al producto fuera de conformidad con las normas de seguridad relevantes Important Safety Information
36. automated light that can project images change and mix dichroic colors and switch from hard edge to soft edge all within a compact system SHOWGUN provides high energy focused or soft edge washes and gobo projection with a 10 inch 250 mm output beam and an innovative LED Tracking System A new patent pending optical design incorporates a proprietary optically accurate polymer microfresnel lens allowing SHOWGUN fixtures to produce a true focused hard edge or a soft edge combination without the need for two separate fixture types The true focused hard edge allows SHOWGUN to project High End Systems Lithopattern images while the soft edge abilities exceed industry standards Soft edge hard edge enabling for SHOWGUN fixtures is easily accomplished from any lighting console The SHOWGUN LED Tracking System is a homogeneously mixed RGB LED circular array that you can match to the color of the main output beam or use to project a complementary color by mixing RGB values Producing over 5000 lumens of output the LED Tracking System works in tandem with the SHOWGUN fixture s other features The SHOWGUN fixture s main output uses a 2000 watt short arc metal halide lamp with a FastFit socket design that allows for a more compact reflector combination SHOWGUN Features Fixture Proprietary Short Arc Lamp and optics produce exceptional light output e Variable beam angles for SHOWGUN hard edge and soft edge Zoom range from 9 18
37. chriebenen Typ und Nennwert entsprechen 5 Einen Mindestabstand von 4 Meter zu den angestrahlten Objekten einhalten 6 Dieses Ger t darf nur an eine Zweigleitung mit einem berlastungsschutz von h chstens 20 A angeschlossen werden Warnung Zum Schutz Gegen Gef hrliche K rperstr me 1 5 Wenn dieses Ger t ohne einen Netzkabelstecker erhalten wurde ist der entsprechende Netzkabelstecker entsprechend dem folgenden Code anzubringen Braun Unter Spannung stehend Blau Neutral Gr n Gelb Erde Vor dem Austauschen von Lampen oder vor Wartungsarbeiten stets den Netzstecker ziehen Diese Ger te sind nur zum Einbau in trockenen Lagen bestimmt und m ssen vor Regen und Feuchtigkeit gesch tzt werden Servicearbeiten sollten nur von Fachpersonal ausgef hrt werden Das Ger t enth lt keine wartungsbed rftigen Teile Dieses Ger t geh rt zur Klasse I Dieses Ger t mu geerdet werden Warnung Zum Schutz Gegen berm ssige Ultraviolett UV Bestrahlung I 2 Die Schutzabdeckungen Linsen und der UV Schutz m ssen ausgewechselt werden wenn sie sichtlich derma en besch digt sind da sie ihre Wirksamkeit einb en z B infolge von Rissen oder tiefen Kratzern Nie direkt in die eingeschaltete Lampe schauen Warnung Zum Schutz Vor Verletzungen 1 Verwenden Sie bei der Installation des Beleuchtungsk rpers ein zus tzliches Sicherheitskabel VORSICHT Bei einer hei e Lampe best
38. ct may use one or more of the following patents US 4 392 187 US 4 602 321 US 4 688 161 US 4 701 833 US 4 709 311 US 4 779 176 US 4 800 474 US 4 962 687 US 4 972 306 US 4 980 806 US 5 010 459 US 5 031 078 US 5 073 847 US 5 078 039 US 5 186 536 US 5 209 560 US 5 278 742 US 5 282 121 US 5 307 295 US 5 329 431 US 5 331 822 US 5 367 444 US 5 402 326 US 5 414 328 US 5 426 576 US 5 430 629 US 5 432 691 US 5 454 477 US 5 455 748 US 5 502 627 US 5 506 762 US 5 515 254 US 5 537 303 US 5 545 951 US 5 588 021 US 5 590 954 US 5 590 955 US 5 640 061 US 5 647 662 US 5 691 886 US 5 702 082 US 5 728 994 US 5 758 955 US 5 758 956 US 5 769 527 US 5 769 531 US 5 774 273 US 5 788 365 US 5 794 881 US 5 795 058 US 5 798 619 US 5 806 951 US 5 812 596 US 5 823 661 US 5 825 548 US 5 828 485 US 5 829 868 US 5 857 768 US 5 882 107 US 5 921 659 US 5 934 794 US 5 940 204 US 5 945 786 US 5 953 151 US 5 953 152 US 5 969 485 vi SHOWGUN User Manual US 5 980 066 US 5 983 280 US 5 984 248 US 5 986 201 US 6 011 662 US 6 029 122 US 6 048 080 US 6 048 081 US 6 054 816 US 6 057 958 US 6 062 706 US 6 079 853 US 6 126 288 US 6 142 652 US 6 142 653 US 6 172 822 US 6 175 771 US 6 188 933 US 6 208 087 US 6 219 093 US 6 220 730 US 6 241 366 US 6 249 091 US 6 255 787 US 6 256 136 US 6 261 636 US 6 278 542 US 6 278 545 US 6 278 563 US 6 288 828 US 6 326 741 US 6 327 103 US 6 331 756 US 6 346 783 US
39. cus sharpens the output by moving the air spaced achromatic lens located inside the lamp housing MSpeed Motor Speed The MSpeed sets the time required for a motor to complete movement when changing from one position to another MSpeed provides a means for all motors to reach their target position at the same time even though each motor may have different distances to travel MSpeed movement is extremely smooth because the fixture controls its own movements and is not dependent on DMX refresh rates MSpeed times vary from 0 15 seconds to 252 7 seconds However if you apply MSpeed to a parameter be sure that the delay value length of time allowed for the entire look is longer than the MSpeed value to allow the motors to complete their movement before the end of the cue An MSpeed value that is longer than the delay value could produce an undesirable result for example no light output during the scene For a listing of exact MSpeed times see Appendix A MSpeed Conversion Table on page 53 MS peed can be applied to the Pan and Tilt Color and Gobo functions You can disable Pan and Tilt MSpeed with the Control parameter to allow MSpeed to apply only to Color and or Gobo parameters Macros The Macro parameter controls Internal Effects macros These are factory programmed sequences that allow you to quickly program complicated looks in one scene cue Each Internal Effect macro modifies a specific set of parameters while allowing user
40. drive Pan and Tilt motors They are located on the back of the electronic housing s display panel Pan Board Tilt Board L Jp M1 M2 MTG2 HD Status board When replacing a board observe the following warnings WARNING AN Disconnect power before servicing Equipment surfaces may reach temperatures up to 130 C 266 F Allow the fixture to cool before handling fia G SHOWGUN User Manual 43 CHAPTER 5 Maintenance and Troubleshooting Replacing Lithopatterns This section explains how to remove and replace individual components in the rotating gobo wheels for SHOWGUN fixtures These directions apply to any gobo or lithopattern in SHOWGUN fixtures that adheres to the specifications see LithoPattern Specifications on page 6 Replace lithopatterns or effects if they are damaged or broken to change their order in the wheel to clean them or to install a new or custom lithopattern or effect If applicable remove all pieces of broken glass in the fixture before beginning WARNING Disconnect power before servicing 74 Equipment surfaces may reach temperatures up to 150 C a 302 F Allow the fixture to cool before handling To replace a lithopattern in the rotating gobo wheel 1 Remove the fixture s bezel cover and rotate the gobo wheel until the selected lithopattern is easy to access 2 Locate the spring securing the lithopattern to the wheel Pull the spring tip
41. eht Explosionsgefahr Nach dem Abschalten der Netzspannung sollten Sie etwa 5 Minuten warten bevor Sie das Lampengehause ffnen Sch tzen Sie beim Auswechseln der Lampen Ihre H nde und tragen Sie eine Schutzbrille Die Oberfl chen des Ger tes k nnen Temperaturen bis zu 160 C erreichen Vor dem Anfassen stets 5 Minuten lang abk hlen lassen Falls die Lampe besch digt oder durch W rmeeinwirkung verformt ist mu sie ausgewechselt werden 58 SHOWGUNS User Manual Appendix B Important Safety Information Ap ndice C Informaci n Importante De Seguridad Advertencia Para Protecci n Continua Contra Incendios l Oo Ul A q N Este equipo se dise a para el uso con l mparas especificadas s lo El uso de cualquier otro tipo de l mpara pued resultar peligroso y pued anular la garant a No monte el equipo sobre una superficie inflamable Mantenga una distancia m nima de materiales combustibles de 1 0 metro Cambie los fusibles nicamente por otros que sean del tipo y la clasificaci n especificadas Guarda una distancia m nima a objetos iluminados de 4 0 metro Este equipo debe conectarse a un circuito que tenga una protecci n m xima contra las sobrecargas de 20 A Advertencia Para La Protecci n Continua Contra lectrocuciones l D Si se recibi este equipo sin el enchufe de alimentacion monte usted el enchufe correcto seg n el clave siguente moreno vivo azul neut
42. f DMX data loss longer than five minutes SHOWGUN User Manual 13 CHAPTER 2 Setup and Configuration 14 SHOWGUN User Manual Chapter 3 SHOWGUN Menu System The onboard Menu system provides fixture configuration options This chapter shows you how to access and navigate the Menu System the options available at each Menu level and includes examples Navigating the Menu System The onboard Menu system lets you perform the following functions at the fixture level Assign a DMX start channel Access and set fixture options View fixture status e Crossload software between fixtures The SHOWGUN Display The front panel on SHOWGUN fixtures has a dot matrix display and six arrows on navigation This display reduces the menu levels required and dramatically increases usability with the capability of displaying up to two 16 character lines of text Use Left and Right arrows to Use Up and Down arrows to move through the current select from available value or menu level options setting options o 4 Use the Menu button on the left Use the Enter button on the when viewing the display to right when viewing the display unlock the menu and move back Use the four way Center to select the currently displayed to the previous menu level button to navigate through levels menu value or option SHOWGUN User Manual 15 CHAPTER 3 SHOWGUN Menu System The SHOWGUN fixture can sense orientation and automatically i
43. fixture s DMX start channel DMX_C HH Any errors present are also displayed in an 8 character error description Fixture Softuiare Version The software version loaded on the fixture can vary even between units purchased at the same time The latest software version is always posted on the High End Systems website www highend com support DMX Start Channel The DMX Start Channel is the first channel currently assigned to that fixture in its range of channels on a DMX link To reset the DMX start channel see Setting DMX Start Channel on page 20 For more information on DMX Start channels see Determining DMX Start Channel Assignment on page 20 Error Message Display Errors are displayed in large 8 character form when the menu system is locked Unlocked the menu system s 2 line format displays more detailed information For information on accessing the detailed error message see Display Errors on page 30 16 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System Unlocking the Menu System To unlock the menu system press and hold the Menu button until the display changes to the two line format You will need to hold the Menu button for a few seconds before the menu unlocks to protect against an inadvertent menu change DMX Address Menu is the first option on the top menu level Exiting the Menu System To exit the menu system keep pressing the Menu button to back out of each menu level until the High End Systems logo appear
44. g on its base WARNING AN Equipment suitable for dry locations only Do not expose this equipment to rain or moisture CAUTI ON Always use a secondary safety cable when mounting this fixture Do not mount on a flammable surface or within 1 m 3 ft of a flammable object Maintain a minimum focus distance of 4 m 13 1 ft from any flammable 4m f object 4m f Maintain a minimum focus distance to non flammable lighted object of 3 m 9 8 ft Note Due to the wide variety of possible lighting designs High End Systems cannot make specific mounting recommendations Consider the following procedure as a suggested guideline only 8 SHOWGUN User Manual CHAPTER 2 oetup and Configuration Mounting the Fixture Upright CAUTI ON N Do not mount the fixture upright without the four rubber feet attached To mount the fixture upright place the fixture on a sturdy stable non flammable surface that will support more than the 63 5 kg 140 Ib weight of the SHOWGUN fixture If the surface is above floor height use safety cables to secure the fixture to the surface Truss Mounting When mounting the fixture on a truss or another type of support Verify the truss or support will handle the combined weight of all the devices on the truss e Always mount the SHOWGUN fixture using the mounting bracket assembly that shipped with your fixture and a safety cable attached to the fixture s base WARNI NG Before mounting
45. h very high temperatures Allow the fixture to cool before handling A e E E be SHOWGUN User Manual V Warranty Information Limited Warranty Unless otherwise stated your product is covered by a one year parts and labor limited warranty Dichroic filters and LithoPatterns high resolution glass gobos are not guaranteed against breakage or scratches to coating It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and dealer or distributor If purchase date cannot be provided date of manufacture will be used to determine warranty period Returning an ltem Under Warranty for Repair It is necessary to obtain a Return Material Authorization RMA number from your dealer or point of purchase BEFORE any units are returned for repair The manufacturer will make the final determination as to whether or not the unit is covered by warranty Lamps are covered by the lamp manufacturer s warranty SHOWGUN fixtures must be returned in its original roadcase Any other parts returned to High End Systems must be packaged in a suitable manner to ensure the protection of such Product unit or parts and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts and with an RMA number Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction Ship returned Product units or parts to 2105 Gracy Fa
46. handling Fixture Component Replacement Replacing Fuses Locating Fuses Fuse Fuse Location and Access Symptom of Failure Motor Power One fuse located on each Power Supply s Fixture shuts down and will not Supply Input input board receive power Motor Power Two fuses located on the Pan bracket Fixture shuts down and will not Supply Output receive power Lamp Power Two fuses located on the power supply Lamp will not strike Supply Input board next to the mains connection 2 phase 1 and F2 on the upper left corner of each Motors driving associated functions driver boards board will not operate Board LEDs are off SHOWGUN User Manual 39 CHAPTER 5 Maintenance and Troubleshooting Fuse Location and Access Location and Access Symptom of Failure of Failure 3 m One mE I D plus one extra on the each board Pan or EM xn board related motors and driver boards fans will be off LED Control One Fuse LEDs won t light Board Replacement Fuses Motor Power Supply Input 2 5A 250V Slow Blow 90403027EF Motor Power Supply Output 5A 250V Slow Blow 90403012EF 2 phase Driver Boards 2 5A 125V Slow Blow SMF Littelfuse 90402016EF 3 phase Pan and Tilt Board LED Control Board 5A 125V Slow Blow SMF Littelfuse 90412027EF Lamp Power Supply Input 20A 250V Very Fast 90403030EF Replacing the Lamp RI SK OF EXPOSURE TO EXCESSI VE ULTROVI OLET UV RADI ATI ON Change shields and lenses if the
47. he Enter button down for 5 seconds to select Lamp Status This option displays the current Lamp Status as LAMP OFF LAMP ON LAMP STRIKING or LAMP ERROR Software Version This option display s the fixture s CPU board Software version The version number is composed of V Major Minor Build SHOWGUN User Manual 29 CHAPTER 3 SHOWGUN Menu System Module Version This option displays the current hardware and software versions for the following components Pan Tilt Shutter Cyan Magenta Yellow Edge Gobo Rotate Focus Zoom lris RGB LED Control Display Errors This menu option displays current errors in a descriptive 32 character text field To DISPLAY ERRORS 1 4 Press the Menu button to unlock the menu system or to move back up the system to the top level menus Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select Use the left and right arrows on the Center button to scroll to the DISPLAY ERRORS menu option and press the Enter button to select Use the up and down arrows on the Center button to view the list of current errors Next DMX Channel Use this option to view the next available DMX Start channel on the link following this fixture and is based on the fixture s specific configuration The value displayed uses the formula current Start channel 30 1 30 SHOWGUN User Manual Chapter 4 Fixture Progra
48. he same side as the lamp blower exhaust 3 Rotate the head and clean the outside of the lens 4 Reach inside the head to clean the back side of the lens 5 Replace the door and apply power to re home the fixture Achromatic Lens 1 The Achromat consists of two air spaced optical lens components Loosen the thumb screw and holding both lenses remove them from the fixture 2 Separate to clean 3 Reassemble the lenses The double convex fits against the concave side of the top lens Align the arrow to point toward the top lens 4 Replace the lenses with the double convex on the bottom toward the lamp 5 Tighten the thumbscrew The lens will fit loosely SHOWGUN User Manual 45 CHAPTER 5 Maintenance and Troubleshooting Reflector l Loosen two captive screws on each side to remove the two side bezels 2 Loosen four captive screws to remove the rear bezel 3 Using a 3 mm hex remove the four MA screws and slide the hot mirror mount out of the unit 4 Slide the reflector out of the mirror mount 5 Clean the reflector and replace Filter There is a washable filter located on one side of the electronics housing attached with velcro Remove wash with soap and water Allow to dry and then reattach 46 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting Production Homing If dimming or color flags are hitting endstops or if flag
49. i Dei Raggi Ultravioletti Non usare questa apparecchiatura se il sistema di chiusura della lampadina non e completo o se gli scudetti le lenti si sono visibilmente danneggiati di maniera tale che la loro efficacia sia stata ridotta ad esempio se vi sono visibili spaccature o graffi profondi Mai guardare direttamente verso la lampadina quando sia accesa Avvertenza Per Non ferire Ad Altre Persone l 2 Use cable secundario de seguridad al montar este aparato Avvertenza La lampadina calda potrebbe esplodere Spegnerla per 5 minuti prima di aprirla Usare protezzioni per le mani e per gli occhi prima di cambiare la lampadina Le superfici della apparecchiatura possono arrivare a temperature di 160 gradi centrigradi 194 gradi f Aspettare 5 minuti prima di maneggiare Cambiare la lampadina se si danneggia o se si e deformata dovuto alle alte temperature 60 SHOWGUNS User Manual Appendix B Important Safety Information Vigtig Sikkerhedsinformation Advarsel Beskyttelse mod elektrisk chock VIGTIGT LEDEREN MED GUL GROEN ISOLATION MAA KUN TILSLUTTES KLEMME MAERKET T ELLER SHOWGUN User Manual 61 Appendix B Important Safety Information 62 SHOWGUN User Manual
50. ide Mounting and Angular Mount by Moving Truss To insure uninterrumpted movement of pan and tilt use Outrig mode Setting the Outrig mode in the Control parameter of your DMX controller lets you turn the option on or off as needed during a production when trusses move to an acute angular position for example Note Because this is a DMX mode it will not persist in the fixture SHOWGUN User Manual 37 CHAPTER 4 Fixture Programming 38 SHOWGUN User Manual Chapter 5 Maintenance and Troubleshooting Maintaining and servicing the SHOWGUN fixture includes replacing parts and cleaning the unit General troubleshooting tips help you identify potential problems SHOWGUN fixtures have been designed for easy access for service However all service must be performed by qualified personnel only Always observe the following cautions and warnings N CAUTI ON TO AVOID INJURY FROM FALLI NG COMPONENTS Never operate with missing or loose fasteners or screws WARNING DANGER OF ELECTRICAL SHOCK Class 1 equipment This equipment must be earthed Do not connect to an ungrounded supply Equipment suitable for dry locations only Do not expose this equipment to rain or moisture Disconnect power before re lamping or servicing EX Do not mount on or within 4 M of flammable objects 7 DANGER INTENSE HEAT Equipment surfaces may reach temperatures up to 150 C iE 302 F Allow the fixture to cool before
51. iguration Setting the DMX Start Channel Each SHOWGUN fixture requires a block of 30 consecutive channels on a 512 Channel DMX link Up to seventeen 30 channel standard SHOWGUN fixtures can be assigned to a single 512 Channel DMX link For more information on Start Channels see Determining DMX Start Channel Assignment on page 12 To Set the Start Channel on an SHOWGUN Fixture l Access the fixture s menu system via the dot matrix display on the fixture s front panel For a detailed description of the menu system see Chapter 3 SHOWGUN Menu System on page 15 Use Left and Right arrows to Use Up and Down arrows to move through the current select from available value or menu level option setting options Use the Menu button on the left Use the Enter button on the when viewing the display to right when viewing the display to unlock the menu and move back Use the four way Center button select the currently displayed to the previous menu level to navigate through levels menu value or option Note Navigation system buttons functions invert automatically when the fixture is turned upside down 2 Unlock the menu system by pressing and holding down the Menu button until the extended 2 line display appears DMX Address menu is the first option at the top menu level 3 Press the Enter button to select The display will show Set DMX Start Channel The display will show the start channel currently assigned to the fixture 4 Use the
52. ing data D3 D1 D1 D2 D3 D4 D1 D2 Z D 6 lt Z O Orange O Not receiving information from 2 amp 3 phase boards Board receiving proper voltage O Board not receiving power Currently not used Green Receiving data OFF Yes if data is applied Not receiving data Green No Receiving data O O CPU board Z O FF Board not receiving data or power ra Dim flickering Board programmed properly L L Green L L L Board not programmed Receiving information from 2 amp 3 Receive phase boards board Z Z O Yes if data is applied Not receiving data O Transmitting data Yes if data is applied Not transmitting data Yes if data is applied Board not discovered Board is discovered Board Receiving data Board not receiving data Z wm Flashing Red LED E Off Control G FF FF ZI zZ O O Yes if data is applied SHOWGUN User Manual 51 CHAPTER 5 Maintenance and Troubleshooting 52 SHOWGUN User Manual Appendix A MSpeed Conversion Table The following table lists the MSpeed motor movement times and their corresponding DMX controller values If you have a numeric type controller use the Value Decimal dec column If you have a fader type controller use the Value Percentage 96 column If your controller allows you to program hex values use the Value hex column FD 019 252 99 FC 021 251 98 FB 025 250 98 FA 029 249 9
53. l is the number of the first channel in a consecutive block of channels assigned to a fixture Third SHOWGUN 30 channels C031 31 60 Fixture can be assigned the second block of DMX channels without physi cally being the second fixture on the link Second SHOWGUN 30 channels C069 69 98 To avoid overlapping channels place the start channel at the beginning of a range of available channels large enough to accommodate that fixture type Fourth Studio Spot 18 channels C121 121 138 Every channel in the link does not need to be assigned When setting the Start channel on a fixture remember e A fixture s physical location on the link does not have to coincide with the order of channel range assignments in the link See Row 2 in the above table The fixture s channel range must not overlap any other device s channel range on the link When two devices on the same DMX link have overlapping channel ranges one or both devices will be disabled or behave erratically The single exception would be if two or more fixtures need to respond to controller commands in exactly the same way In that case those fixtures must be the same type for example two SHOWGUN fixtures and must share the entire channel range Shutting Down the Fixture A DMX controller can shut down the fixture remotely with the Shutdown option in the Control Channel or you can simply disconnect from power The SHOWGUN fixture automatically shuts down in the event o
54. mation Appendice C Importanti Informazioni Di Sicurezza Avvertenza Per Prevenire Incendi 1 Quest apparecchiatura disegnata per l uso con le lampade specificate soltanto L uso di qualunque altra lampada di tipo pu essere pericoloso e pu nullo la garanzia Da non montare sopra una superficie infiammabile Mantenere l apparecchio a un minimo di 1 0 metri 3 28 piedi di distanza dai materiali combustibili Rimpiazare i fusibili usando soltanto quelli del tipo e della taratura adatta 5 Mantenere una distanza minima di 4 0 metri 6 56 piedi dagli oggetti accesi Questa apparecchiatura e da collegarsi ad un circuito con una protezzione da sovraccarico massima di 20 amperes Avvertenza Per Prevenire Le Scosse Clettriche l Se questa apparecchiatura stata consegnata senza una spina del cavo di alimentazione collegare la spina appropriata del cavo di alimentazione in base ai seguenti codici marrone sotto tensione blu neutro verde giallo terra Disinnestare la corrente prima di cambiare la lampadina o prima di eseguire qualsiasi riparazione 3 Este equipo se adecua a lugares secos solamente no lo exponga a la lluvia o humedad di Per qualsiasi riparazione rivolgersi al personale specializzato L utente non deve riparare nessuna parte dentro l unita Aparecchio di Classe I Questa apparecchiatura deve essere messa a terra Avvertenza Per Proteggersi Contro Le Radiazion
55. minator LithoPattern Specifications Diameter 64 9 mm 20 mm 2 56 in 008 in Clear Aperture 53 34 mm 25 mm 2 1 in 01 in Concentricity of Clear Aperture 18 mm 007 in Maximum Thickness 2 80 mm 17in 6 SHOWGUN User Manual Chapter e Setup and Configuration SHOWGUN fixture setup includes mounting connecting to power and DMX linking and configuration Use the following steps to set up and configure your SHOWGUN fixture 1 Unpack the fixture Install power cord cap for your location Mount the fixture upright or suspended from a standard truss Connect the fixture to a DMX controller via DMX cabling Connect the fixture to power O U Bb UY N Configure the fixture for DMX control Unpacking the Fixture The SHOWGUN fixture ships in a road case specifically designed to protect the product during transport When unpacking inspect the fixture for physical damage to components High End Systems assumes no responsibility for products that are damaged during transport Return a product for repair in its road case Before sending anything to the factory call your High End Systems dealer distributor for a Return Material Authorization RMA number The factory cannot accept any goods shipped without an RMA number Installing a Power Cord Cap The SHOWGUN fixture s custom power cord ships without a power cord cap Use the information in this section to install the correct power
56. mming DMX Programming Overview A parameter is a fixture attribute that can be controlled to modify the light beam in terms of color beam quality and pattern intensity or focus position DMX programming assigns a DMX value to each of the fixture s parameters A look sometimes referred to a scene or a cue is one combination of parameter settings These looks are the building blocks for show creation Full Speed verses MSpeed Control Some parameters can be set to operate at full speed or MSpeed motor speed Full speed operations are completed in the shortest length of time after the motor starts moving With MSpeed control change occurs smoothly over the entire MSpeed time value selected For example if you select an MSpeed time of 30 seconds the motor will gradually change position until it reaches its new destination at the end of 30 seconds DMX Programming Options Using a DMX controller you can program an unlimited number of looks and retain direct control over the SHOWGUN fixture at all times Programming uiith a DMX Console The Wholehog the Hog iPC and the Road Hog lighting consoles and Hog 3PC software are available from High End Systems to control SHOWGUN fixtures see Related Products and Accessories on page 3 For information on whether your DMX controller supports SHOWGUN fixtures contact the controller s vendor For information on operating your fixture with a controller or control device such as DMX cont
57. munications such as Dataflash AF1000 xenon strobes These devices will block communication between the crossloading fixture and any other SHOWGUN fixtures on the link 2 On the crossloading fixture only unlock the menu system by pressing and holding down the Menu button until the extended 2 line display appears indicating the top menu level 3 Using the left and right arrows on the Center button scroll to the FIXTURE MODE MENU and press the Enter button to select 4 Use the left and right arrows on the Center button to scroll to CROSSLOAD FIRMWARE 5 Use the up and down arrows on the Center button to scroll to the YES option and press the Enter button to store The fixture will upload its software to all other SHOWGUN fixtures on the link When the crossload has finished successfully CROSSLOADING COMPLETE will appear briefly in the display of the crossloading fixture and all other fixtures will automatically home Note If a new boot code was included with the latest software the fixture displays a BOOTDIFF error when it returns to the locked mode of the menu system To correct the boot code copy the new boot code to each fixture see Copying the Boot Code on page 34 26 Test Options Menu Homing the Fixture The SHOWGUN fixture automatically homes all its functions whenever it is turned on To manually home the fixture l Press the Menu button to unlock the menu system or to move back up the system to the top level menus
58. neuste 29 lips 29 SOTWare Ver O zensiert isn 29 e PP 30 nn e 30 Next DMA Chanel rc Ai 30 Chapter 4 Fixture Programming DMX Programming Overview sn a dd ad pedi kk kk ka 31 Full Speed verses MSpeed Control sess nemen nnns 31 DMX Programming Options u nn ae naeh 3l Programming with a DMX Console kk kk kk kk kaka ka kak kak k kak kak kk kak 31 SHOWGUN DMX Parameters kk kk kak kak kk kk kk 32 Pond TIE sa EERER 32 Color MIXING NNN NH IH HHHH HH HMH MMHEM NE See Eee 33 eges 33 Ea PP c S 33 ROCCO RO REO O Er 34 BEEN edes ee ee rn nis 34 LED racking FUNCHONS ana ne ae ee rege 34 LED Tracking System DIMMING sceueeeeeee cece kk kk mee memes 34 Dim Tracking Modern nee _ mm r_ e_o pm mm 34 Tracking System Independent Dim Mode 34 Shutter and Lamp Effects eee kk kk k kk ERE kaka kak ka kaka kaka kk kak kk kk kk kk kk kk kk kk ka 35 ZOO and FOCUS M XE T 36 MS peed Motor Speed rina ria I Rn ae REA load rur 36 WMaCl OS 36 Gondgesle uj qr ne Her er 200 NAN a SAD o 37 Side Mounting and Angular Mount by Moving Truss kk 37 SHOWGUN User Manual Chapter 5 Maintenance and Troubleshooting Fixture Component Replaceme
59. nt nenn 39 RSC EE eo 39 OS ESS a E o 39 Replacement ESS disent den TII A0 aiserpemup dak inno Tr 40 DAVE BOSS esconden 42 PSS DO oraaJ gmmgmmggggg_ggggggggg z 42 ic Ann DET 43 Replacing Lithopatterns ins 44 Cleaning the SHOWGUN Fixture nnns 45 Microfresnel Lens ae UU TTE 45 22 008 518 oM o A PA O o een 45 lir a 46 ali rc M H 46 Production HOMINO tT C 47 Accessing the Bulk Heads sun en ses 47 Iris and Gobo BUHO irte 47 Soft Edge Flag Bulk Head nehmen 47 Flag Calibration Example seminare Mna 48 calibrate thai LI o m 49 Troubleshooting NE ee er ee 50 POWEFSUPPV ee ee ee tree mn 50 Board LED States A dt 51 Appendix A MSpeed Conversion Table 53 Appendix B Important Safety Information cece eee ees 55 Appendice C Importantes Informations Sur La S curit Li 57 Anhang C Wichtige Hinweise F r Ihre Sicherheit esses 58 Ap ndice C Informaci n Importante De Seguridad kk 59 Appendice C Importanti Informazioni Di Sicurezza ssesn k 60 Vigtig Sikkerhedsinformat On A go 61 iv SHOWGUN User Manual Chapter I Product Overvieui The SHOWGUN fixture from High End Systems is a very powerful 100 000 lumen
60. nverts the display and the Center button s functions when the fixture is mounted upside down Navigational Basics 1 Unlock the Menu system by pressing the Menu Y button for a few seconds until the display goes to the 2 line format 2 Use the left and right arrows lt on the Center button to scroll through menu options at the current level 3 Stop at the desired menu and press the Enter button to select Note The new option will not be stored unless the Enter button is pressed 4 If there is another level of menu choices repeat Steps 2 and 3 5 At the option or setting level of the menu use the Up and Down arrows on the Center button to scroll to the desired option or setting The option flashes until the Enter button is pressed Pressing the Enter button stores the new value for that option Pressing the Menu button returns to the previous menu level without changing the value of an option 6 Continue pressing the Menu button to move back up levels until exiting the Menu system Display in Menu Locked Mode The SHOWGUN display panel gives access to the fixture s onboard Menu System When the Menu System is in locked mode the panel displays in large 8 character format designed to be viewed from a distance Under normal circumstances when the display is locked it cycles between displaying the SHOWGUN logo the High End Systems logo the fixture s software version LV the fixture s configuration type STANDARD and the
61. ollowing steps First remove the retaining clip from each lens shaft Push the microfresnel lens up to lift it off the fixture Remove the two M4 socket caps using a 3mm hex key and slide the bulk head out of the unit BR W N m After completing the calibration replace the lens by carefully aligning the worm gears and gently rotating the gears to begin threading the lens shaft back into the fixture SHOWGUN User Manual 47 CHAPTER 5 Maintenance and Troubleshooting 5 Push the lens into the fixture 6 Reattach the retaining clips on the lens shaft Flag Calibration Example This example shows you how to recalibrate the dimmer flags Connect dimmer flag motors directly to 2 phase driver 1 Remove the two M4 socket Loosen two captive screws Locate the 2 phase board Connect one end of a Detach header from motors powering the two DIM flags on the Lower bulk head caps and slide the Lower bulk head out of the fixture to remove electronic housing cover over the display panel and take out the two service harnesses located on the back side of the display panel that controls the dimmer motors Disconnect the M1 and M2 for the two DIM flags on Board 2 the lower front board of the 4 board bracket inside the fixture harness to a flag of the dimmer motor and the other to the corresponding header on the 2 phase board see page 47 You can connect and home one flag or a pai
62. pursuant to part 15 ofthe FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Safety Symbols The following international caution and warning symbols appear in margins throughout this manual to highlight messages This symbol appears adjacent to Caution messages Not heeding these messages could result in personal injury and or damage to equipment This symbol appears adjacent to high voltage warning messages Not heeding these messages could result in serious personal injury gt This symbol indicates the minimum focus distance from a combustible object C I This symbol cautions against mounting the fixture on or near a flammable surface This symbol indicates an explosion hazard This symbol cautions against an Ultraviolet Radiation hazard This symbol indicates that eye protection should be worn to prevent potential injury This symbol warns of a fire hazard This symbol indicates that while operating equipment surfaces may reac
63. r of flags at the same time 48 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting Calibrate the flags 6 10 IT 12 13 Use the up and down Y Using a 2 mm hex key Power up the fixture Unlock the Menu system by pressing Menu Y button for a few seconds until the display goes to the 2 line format Use the left and right arrows to scroll to the Test option Press Enter 4 to select arrows to scroll to SETUP MOTORS Press Enter 4 to A select Use v arrows to scroll to YES and press Enter 4 to select Flags will energize against the standoffs loosen the set screw at the base of the flag Adjust each flag vertically to i the tickmark on the inside standoff Tick marks for vertical flag adjustment Remove the service harness and re attach the connectors to the 2 phase driver board Reinsert the bulk head and replace the two 4M socket caps Home the fixture and test flags Make sure they are not hitting when fully closing from the console or the menu system SHOWGUN User Manual 49 CHAPTER 5 Maintenance and Troubleshooting Troubleshooting Pouier Supply SHOWGUN fixtures have two power supplies PS1 and PS2 that split the power requirements for the different fixture components Power Functions Power Board Connection Pan 3 phase board Focus Zoom Iris 2 phase board Address 8 Zoom 1 Zoom 2 Iris Soft Edge Gobo Rotate 2 phase board Address
64. ral verde amarillo tierra Desconecte el suministro de energ a antes de recambiar l mparas o prestar servicio de reparaci n Questa apparecchiatura e da usarsi in ambienti secchi Non e da essere esposta ne alla pioggia ne all umidita Derive el servicio de reparaci n de este equipo al personal calificado El interior no contiene repuestos que puedan ser reparados por el usuario Equipo de Clase Este equipo debe conectarse a la tierra Advertencia Para Protecci n Continua Contra La xposici n A Radiaci n Ultravioleta UV xcesiva l Cambie el blindaje los lentes si nota una aver a visible a tal grado que su eficacia se vea comprometida Por ejemplo en el caso de grietas o rayaduras profundas 2 Jam s mire directamente a la l mpara en tanto sta est encendida Advertencia Para Protecci n Continua Contra Lesiones Corporales l 2 Al montare questa apparechiatura usare un secondo cavo di sicurezza Precauci n Una l mpara caliente puede constituir un peligro de explosi n No la abra por 5 minutos luego de haberla apagado Lleve puestos un protector ocular y guantes al recambiar l mparas Las superficies del equipo pueden alcanzar temperaturas m ximas de 160 grados cent grados Deje que se enfr en por 5 minutos antes de tocarlas Cambie la l mpara si sta se aver a o deforma por acci n t rmica SHOWGUN User Manual 59 Appendix B Important Safety Infor
65. rms Lane Austin TX 78758 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing materials Freight All shipping will be paid by the purchaser Items under warranty shall have return shipping paid by the manufacturer only in the Continental United States Under no circumstances will freight collect shipments be accepted Prepaid shipping does not include rush expediting such as air freight Air freight can be sent customer collect in the Continental United States REPAIR OR REPLACEMENT AS PROVIDED FOR UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER HIGH END SYSTEMS INC MAKES NO WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO ANY PRODUCT AND HIGH END SPECIFICALLY DISCLAI MS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE HIGH END SHALL NOT BE LIABLE FOR ANY INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGE INCLUDING LOST PROFITS SUSTAINED OR INCURRED IN CONNECTION WITH ANY PRODUCT OR CAUSED BY PRODUCT DEFECTS OR THE PARTIAL OR TOTAL FAILURE OF ANY PRODUCT REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER OR NOT SUCH DAMAGE WAS FORESEEN OR UNFORESEEN Warranty is void if the product is misused damaged modified in any way or for unauthorized repairs or parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state Patents This produ
66. rol software consult the documentation provided with the controller SHOWGUN User Manual 31 CHAPTER 4 Fixture Programming SHOWGUN DMX Parameters DMX console libraries define parameters for the following SHOWGUN functions over a 30 channel range and are copyrighted and available in High End Systems consoles For information on developing libraries for DMX consoles from other manufacturers contact High End Systems cr ERE 7 n 3 nr van 71 8 Yellow 9 Litho Wheel Position Litho Rotate Pan and Tilt Channel Function LED Tracking Red LED Tracking Green LED Tracking Blue The Pan and Tilt parameters control the SHOWGUN fixture s 420 pan range and 216 tilt range Pan and Tilt functions each utilize two channels to provide 16 bit adjustment to a fraction of a degree Pan and Tilt motion for SHOWGUN fixtures can be controlled with MSpeed values see MSpeed Motor Speed on page 36 If you choose to use MSpeed for gobo changes without affecting Pan and Tilt parameters set Pan Tilt MSpeed OFF in the Control parameter Note Optical encoders for pan and tilt correct the fixture s position if the fixture is jarred from its programmed position If a physical obstruction prevents the fixture from correcting its position the fixture times out to prevent wear on the motors If your fixture has timed out remove the obstruction and home the fixture to return it to normal operation
67. s The word AUTOLOCK will appear briefly on the display to indicate the fixture s software is locking the display The display switches back to the large 8 character format and after a few seconds begins the standard display for the locked mode as described above SHOWGUN User Manual 17 CHAPTER 3 SHOWGUN Menu System Menu Map Option Setting Description Notes DMX ADDRESS MENU FIXTURE MODE MENU TEST MENU INFOMATION MENU SET DMX START Selected value becomes the first DMX value CHANNEL 4 in the range for that fixture on a DMX 512 link FACTORY DEFAULT ON Reverts fixture to default setting SETTINGS 24 Indicates a factory default has changed PAN TILT SWAP DISABLED Restores default Pan and Tilt Motion ENABLED Swaps the Pan and Tilt Motion PAN INVERT DISABLED Restores default Pan motor direction TILT INVERT DISABLED Restores default Tilt motor direction ENABLED Inverts Tilt motor direction OFF DISPLAY LEVEL OFF Display fully dimmed when menu is locked DISABLED Disables lamp life tracking LAMP LIFE LIMIT ENABLED Tracks the time the lamp is on and sends a warning at 500hrs DATA LOSS SHORT Shutter closes 1 second after data loss TIMEOUT LONG Shutter closes when fixture shuts down a Eee FIRMWARE Uploads fixture software to all other SHOWGUN fixtures on the link HOME FIXTURE AL Homes Homes all fixture functions fixture functions i a larp at LAMP STATE Indicates or turns lamp off
68. s don t fully move into the aperture you can manually recalibrate the flags using the production homing procedure l Access the affected bulk head and remove it from the fixture 2 Use the service harness headers to replace the connection between the bulk head flag motor and the appropriate 2 phase board location You can connect 1 or two flags to the 2 phase board at a time Flag 1 is the flag nearer the lamp and Flag 2 is the flag farthest from the lamp on a bulk head NOTE The two service harnesses provided are located behind the display panel in the electronics housing 3 Select TEST SETUP MOTORS YES in the menu system to home the flag 4 Loosen the set screw at the base of the flag using a 2 mm hex key and adjust the flag positioning 5 Replace the bulk head and home the fixture NOTE You can also use these steps when replacing a flag Accessing the Bulk Heads All of the bulk head brackets are held in the unit with two M4 socket caps Use a Top Bulk Head 3mm hex key for removal Soft Edge Flags Zoom Iris and Gobo Bulk Head For easy access to this bulk head Center Bulk Head remove Dimmer Bulk Head first Focus Gobo Yellow Flags Soft dge Flag Bulk Head Cyan Flags You can easily adjust the soft edge Lower Bulk Head Dim Flags moving it from the unit using a short 2 Magenta Flags flags on this bulk head without re mm right angle hex key If you choose to remove the bulk head use the f
69. s the Menu button to unlock the menu system or to move back up the system to the top level menus Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select Use the left and right arrows on the Center button to scroll to the TEMPERATURES MENU and press the Enter button to select Use the left and right arrows on the Center button to scroll to MAXIMUM Press the Enter button to select Use the up and down arrows on the Center button to scroll to LED TRACKING Press the Enter button to select and view the temperature recorded in degrees centigrade To reset all the temperature readings back to the current temperature l Press the Menu button to unlock the menu system or to move back up the system to the top level menus Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select Use the left and right arrows on the Center button to scroll to the TEMPERATURES MENU and press the Enter button to select Use the left and right arrows on the Center button to scroll to RESET TEMPERATURE Press the Enter button to select The display will read NO Use the up and down arrow to scroll to YES and hold for 5 seconds to reset all sensors to the current temperature in centigrade Fixture Hours Use this option to view the fixture operation time in hours and minutes 28 SHOWGUN User
70. st menu item at the top level 2 Press the Enter button to select The display will show SET DMX START CHANNEL The display will show the start channel currently assigned to the fixture 3 Use the up and down arrows on the Center button to select a new DMX start channel from 001 483 The display will flash a new option ready for selection Note The last valid Start channel for a SHOWGUN fixture is 483 512 30 1 4 Press the Enter button to accept the new DMX Start channel Note lf the Enter button is not pressed the old value will remain selected after exiting the menu Determining DMX Start Channel Assignment There are 512 available channels on each DMX link divided among all the devices in a particular link A fixture must have a unique Start channel number in order to respond independently to controller commands To determine each fixture s DMX start channel in a link identify the channel range of every fixture on the link Channel range is the number of consecutive channels a fixture requires Each SHOWGUN fixture requires a block of 30 consecutive channels on a 512 Channel DMX link The Start channel is the first number of a fixture s channel range 20 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System The notes in the following table show the various considerations in determining valid Start Channels for fixtures on a 512 DMX link A single 512 Channel DMX link can accommodate up to sixteen 30 channel SHOWGUN
71. the top level to SET PARAMETERS MENU and press the Enter button to select 3 Using the left and right arrows on the Center button scroll to PAN TILT SWAP The current state ENABLED or DISABLED will be displayed 4 Use the up and down arrows on the Center button to scroll to ENABLED to swap pan and tilt or DISABLED to revert fixture to default setting and press the Enter button to select 22 SHOWGUN User Manual CHAPTER 3 SHOWGUN Menu System Pan Invert This menu option inverts the direction of the pan motor to coordinate movements between fixtures mounted opposite each other horizontally To invert the fixture s Pan motion l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Using the left and right arrows on the Center button scroll through the top level to SET PARAMETERS MENU and press the Enter button to select 3 Using the left and right arrows on the Center button scroll to PAN INVERT The current state ENABLED or DISABLED will be displayed 4 Use the up and down arrows on the Center button to scroll to ENABLED to invert Pan movement or DISABLED to revert fixture to default setting and press the Enter button to select Tilt Invert This menu option inverts the direction of the tilt motor to coordinate movements between fixtures on a link facing each other vertically To invert the fixture s Tilt motion l Press the Menu button to unlock
72. towards the center of the aperture The spring will release from its groove inside the aperture 3 Remove the spring and lithopattern 4 Place the new lithopattern into the aperture 5 Install lithopatterns with the coated side away from the lamp To determine which side of the lithopattern is coated place the tip of a pen against each side of the lithopattern and view it from a slight angle On the coated side the tip of the pen appears to touch its reflection On the uncoated side there appears to be a gap between the pen and its reflection 6 Replace the spring 7 After replacing the lithopattern clean it by using a soft lint free cotton cloth and a mild glass cleaning solution containing no ammonia 44 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting Cleaning the SHOWGUN Fixture All glass parts should be cleaned with using a mild glass cleaner containing no ammonia and a soft lint free cotton cloth You can use a diffusion cleaning applicator HES p n 90901001 to access and clean the outside of the Dual Acromat lens lithos color and soft edge flags Microfresnel Lens You can clean both sides of the Microfresnel lens without removing it from the fixture 1 Using your DMX console set the Zoom parameter to fully extend the lens 2 Disconnect the fixture from power and after allowing the fixture to cool loosen two captive screws to remove the the lamp housing door on t
73. unctions option in the Shutter Lamp Function channel the Shutter channel lets you create lamp boost lightning and strobing effects Shutter Lamp Function Shutter Channel Lamp Functions Closes shutter Periodic lamp strobes lamp at specified intervals from slow to fast Allows all SHOWGUN Fixtures on the DMX link to strobe their lamps at random times from slow to fast Allows all SHOWGUN Fixtures on the DMX link to strobe their lamps at random times in unison from slow to fast Boost lamp black Six time ranges from 1 25 second Note Boost lamp white Six time ranges from 1 25 second Note Lightning strikes Six lightning variations are available The Dim channel scales the overall brightness of the lightning stroke Opens shutter NOTE The Boost effect boosts the Lamp above the fixture s Watt level for the specified period of time The lamp is also boosted during the Lightning effects Before another Boost or Lightning effect can occur the Shutter channel must be moved to either closed or open or the Lamp Control channel must be moved outside the Lamp Function range Boost effects to black boost the lamp for a specified time then close the shutter Boost effects to white boost the lamp for a specified time then leave the shutter open with the lamp dimmed SHOWGUN User Manual 35 CHAPTER 4 Fixture Programming Zoom and Focus Zoom moves the 10 microfresnel lens in and out to make the image larger Fo
74. uttons The number at the beginning of each line indicates the first channel with a value displayed on that line For example line 1 HH HH displays values for channels 1 2 and 3 Line 4 HH HH HH displays values for channels 4 5 and 6 To access the DMX VALUES MENU l Press the Menu button to unlock the menu system or to move back up the system to the top level menus 2 Use the left and right arrows on the Center button to scroll to the INFORMATION MENU and press the Enter button to select 3 Use the left and right arrows on the Center button to scroll to the DMX VALUES MENU and press the Enter button to select 4 Use the up and down arrows scroll through the channel range The display shows 6 DMX values per screen in two lines of 3 values each The number at the beginning of the line indicates the channel number corresponding to the first value in that line SHOWGUN User Manual 27 CHAPTER 3 SHOWGUN Menu System Temperatures Menu The SHOWGUN fixture contains temperature sensors that track current maximum and minimum temperatures produced in the unit Sensors monitor the air temperature of the electronics housing the lamp housing and the LED System Initially the setting for current maximum and minimum temperatures are equal As the sensor detects temperature changes the fixture adjusts the minimum and maximum settings To view maximum temperature the LED System reached since the last reset l Pres
75. xpositions xcessives Aux Rayons Ultra Violets UV 1 2 Changer les blindages ou les crans s ils sont visiblement endommag s au point que leur efficacit aient t alt r e par exemple par des fissures ou de profondes gratignures Ne jamais regarder directement la lampe quand celle ci est allum e Mise n Garde Pour Une Protection Permanente Contre Les Blessures Corporelles l 2 Lors de l assemblage utiliser un c ble de s curit secondaire AVERTISSEMENT Les lampes chaudes comportent un risque d explosion Apres l avoir teinte attendre 5 minutes avant de la d gager Lors du remplacement de la lampe une protection des yeux et des mains est requise Les surfaces de l appareil peuvent atteindre des temp ratures de 160 C Laisser refroidir pendant 5 minutes avant la manipulation 4 Changer la lampe si elle est endommag e ou thermiquement d form e SHOWGUN User Manual 57 Appendix B Important Safety Information Anhang C Wichtige Hinweise F r Ihre Sicherheit Warnung Zum Schutz Vor Brandgefahr E Diese Ausr stungen sind f r Gebrauch mit angegebenen Lampen nur entworfen Der Gebrauch irgend eines anderen Lampentyps k nnte Sie gef hrden und Ihre Garantie au er Kraft setzen 2 Das Ger t nie auf einer feuergef hrlichen Fl che montieren 3 Stets einen Mindestabstand von 1 Meter zu brennbaren Materialien einhalten 4 Zum Ersatz nur Sicherungen verwenden die dem vorges
76. y have become visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches Never look directly at the lamp while lamp is on Do not operate without complete lamp enclosure in place or when lens is damaged Serious injury may result from the generation of ozone by this lamp system A proper means of venting must be provided RISK OF POSSIBLE LAMP EXPLOSI ON Do not open for five minutes after switching off Service and maintenance should be performed only by qualified personnel as determined by the high pressure lighting fixture manufacturer Wear eye and hand protection when re lamping DANGER INTENSE HEAT Equipment surfaces may reach temperatures up to 150 C 302 F Allow the fixture to cool before handling This equipment is designed for use with a Philips MSR Gold SA SE metal halide lamp only Use of any other type lamp may be hazardous and may void the warranty S A 40 SHOWGUN User Manual CHAPTER 5 Maintenance and Troubleshooting The SHOWGUN fixture uses a proprietary 2000 watt short arc metal halide lamp with a fast fit base DANGER I NTENSE HEAT AA Equipment surfaces may reach temperatures up to 150 C 302 F Allow the fixture to cool before handling To change the lamp l Loosen the two captive screws open the lamp panel to access the base of the lamp 2 Rotate the lamp base to align with the slots in the housing and pull out of

Download Pdf Manuals