Home
Technical Specification
Contents
1. 5 Ben SM i aOmcae MECe VEN SUDENTCACTIVE 0rsssscscasarterscncessesavssarscueanensaeavarerirsanaet 85 dbm 10 max 5 mW 30 Imax 2 A TERMS OF WARRANTY The producer is obliged to repair the device free of charge if during the warranty period flaws occur due to a producer s fault The warranty includes a 12 month periond since the date of purchase The warranty will not be accepted in the following cases exceeding admissible values of electric current and voltage included in the manual operating the device without accordance to the manual inappropriate fitting and use making any repairs on one s own flooding the device with water or any other liquid tearing or breaking the warranty seal changing the warranty card or lacking the document proving the purchase receipt invoice After warranty service and technical examination of the delivered equipment is paid Inthe case of complaint the complete device together with remote controllers and the description of the defect warranty card return address and telephone number should be delivered to the point of Sale fitting first and inan emergency situation to the producer Decision of the Corado Service concerning warranty repairs is final Warranty does not include batteries equipment and remote control casings and bundles of wires attached to the equipment In case of losing or damaging the Warranty Card copies will not be issued Corado takes no material or le
2. next position in the configuration process press the D push button of the K 2 programmer for a short time LED 1 diode of the K 2 programmer and the buzzer will turn on simultaneously 3 times every 3 seconds for 0 5 second For RSC 2f version Channel 1 is assigned the Functional push button on the key fob transmitter Channel 2 is assigned the Assistant push button on the key fob transmitter Setting monostable mode position in the configuration procedure To switch into monostable mode for channel 1 press the Main push button on the key fob transmitter for a Short time double simultaneous signaling by LED 1 and the buzzer indicates setting channel 1 into monostable mode To switch into monostable mode for channel 2 press the Functional push button on the key fob transmitter for a short time double simultaneous signaling by LED 1 and the buzzer indicates setting channel 2 into monostable mode a If you wish to exit the configuration procedure disconnect the power supply of the K 2 programmer for at least 5 seconds b If you wish to move to the next position in the configuration process press the D push button of the K 2 programmer for a short time LED 1 diode of the K 2 programmer and the buzzer will turn on 21 Simultaneously 4 times every 3 seconds for 0 5 second For RSC 2f version Channel 1 is assigned the Functional push button on the key fob transmitter Channel 2 is assigned the Assistant push button on the key fob tra
3. LOW ones RADIO SOLUTIONS RSCA 2 channel remote control DAS WMLEPRIStconuk MO IPHSTCONUK RSC 2 2 Channel Remote Control Update documents 2009 11 04 version 1 2 KEG E Fe Q Operating Manual amp Applications Notes http docs google com View id dhsr2cgs_31jm6 s5v3 Dear Customer 5 efore as ny KSC 2 remote control System we ask gou to become acquainted with the content of this manual Acquired knowledge of operation and fanc lions of the purchased ESCL remote control system will ensure proper fanc tioning of the controller With our compliments LEKS Company Table of contents User manual Service manual Glossary of basic terms K 2 Programmer General description Operation of the K 2 programmer Primary functions Configuration of the RSC 2 radio controller Versions of the RSC 2 radio controller Logging the key fob transmitters Types of the key fob transmitters 8 Bistable mode setting Functions of the key fob buttons RSC 2d Monostable mode setting Functions of the key fob buttons RSC 2e Time recording Functions of the key fob buttons RSC 2f RD 24 voltage reducer Description of RSC 2 controller outputs 13 Basic technical data Fitting the RSC 2 radio controller Terms of warranty Example fitting support Repairs Glossary of basic terms BISTABLE MODE Each press of the key fob transmitter push button changes the output to the opposite switches the negative powe
4. ammer Possibility to set a channel into monostable mode with timing adjustable from 0 2 to about 600 seconds signaling the registration of the last 6th key fob transmitter in EEPROM memory Independent reset switch off of a channel channels using a 3 button key fob transmitter e g Banan 8 Channel outputs with overcharging and thermal protection 9 Possibility to connect inductive devices e g relays 10 Controlling the negative power supply open collector output Versions of the RSC 2 radio controller RSC 2d remote controller with two dependent channels Press the Main push button of the key fob transmitter to switch on the negative power supply on channel 1 simultaneously switching off the negative power supply on channel 2 Press the Functional push button of the key fob transmitter to switch on the negative power supply on channel 2 simultaneously switching offthe negative power supply on channel 1 RSC 2e remote controller with two independent channels Press the Main push button of the key fob transmitter to switch on off the negative power supply on channel 1 Press the Functional push button of the key fob transmitter to switch on off the negative power supply on channel 2 RSC 2f remote controller with two dependent channels Press the Functional push button of the key fob transmitter to switch on the negative power supply on channel 1 simultaneously switching off the negative power supply on channel 2 P
5. el Bulb 2 Example connection diagram Example connection diagram RSC 2 for controlling 24V bulbs RSC 2 for controlling 12V bulbs Figure 6 Figure 7 K 2 programmer K 2 programmer allows to change current settings of RSC 2 controllers By means of this programmer installer can check the functioning of the controller and change settings to suit user s needs A schematic diagram of the configuration process is shown below Position Delete existing key fob transmitters and logg new ones signalling LED diode blinks once in 3 seconds Position Bistable mode setting signalling LED diode blinks twice in 3 seconds Position Monostable mode setting signalling LED diode blinks three times in 3 seconds a 1 channel LED 1 Position Time registration for monostable mode channel LED 2 signalling LED diode blinks four times in 3 seconds gt nate Operation of the K 2 programmer When the amp push button of the K 2 programmer is being pressed voltage between 0 45V and 0 65V will appear between controller outputs no 86 and 87 Introducing this requirement protects the RSC 2 controller from accidental entering configuration mode during standard operation of the controller Connecting the K 2 programmer to the RSC 2 controller To connect the K 2 programmer to the RSC 2 controller a disconnect the power supply from the RSC 2 controller b disconnect the RSC 2 controller f
6. eneral description RSC 2 device allows the user for remote switching on and off electronic and electric devices using a key fob transmitter Radio transmission used for communication between the key fob transmitter unit and the RSC 2 controller is completely safe thanks to the application of KeeLoq encrypted data transmission system developed by Microchip Technology Inc In terms of external design and dimensions it corresponds exactly to commonly used relays HFV4 HFV7A made by Hogfa GRL S 112D made by Goodsky or the following models made by Bosch Minirelays 332 019 103 0 332 019 110 0 332 019 109 0332 209 150 0 332 209 138 In order to fit the RSC 2 controller standard relay sockets installed in cars can be used for the aforesaid relays RSC 2 is a small but extremely functional device containing two radio controlled channels which can operate in either dependent or independent mode according to the software version RSC 2 controllers may co work as executive components with other controlling signaling units Primary functions of RSC 2 KeeLog Dynamic code hopping technology made by Microchip Technology Inc Two channels working in either independent mode RSC 2e or dependent mode RSC 2d and RSC 2f Saving operating conditions of channels configuration and logged key fob transmitters in EEPROM memory after disconnecting the power supply up to 10 years simple and convenient system configuration using a K 2 progr
7. er and hold it until LED 1 blinks twice and there is a buzzer signal Such a signalling indicates logging the key fob transmitter in the controller memory The procedure is the same for the following key fob transmitters Up to 6 key fob transmitters can be logged in the controller While attempting to logg a seventh transmitter the controller will indicate the end of the process of logging key fob transmitters by a short blink of LED 1 and buzzer 0 5 second once every 1 second 19 a If you wish to exit configuration mode disconnect power supply from the K 2 programmer for at least 5 seconds b If you wish to move to the next position in the configuration process press the D push button of the K 2 programmer LED 1 of the programmer and the buzzer will turn on simultaneously twice every 3 seconds for 0 5 second Setting bistable mode position in configuration process To set bistable mode for channel 1 press for a short time the Main push button on the key fob transmitter double simultaneous signaling by LED 1 and the buzzer informs about setting channel 1 into bistable mode To set bistable mode for channel 2 press the Functional push button on the key fob transmitter double simultaneous signaling by LED 1 and the buzzer informs about setting channel 2 into bistable mode a If you wish to exit the configuration procedure disconnect the power suply of the K 2 programmer for at past 5 seconds b If you wish to move to the
8. gal liability for losses resulting from automatic damage of the equipment random accidents third party interferences or inappropriate fitting Filling in all points contained in the warranty and a readable customers signature are basic conditions while examining the request for warranty repairs Corado declares that the product has been designed and produced compliant with Safety of use norm EN 60950 1 electromagnetic compatibility norm EN 301 489 1 radio requirements compliance norm EN 300 220 3 Date of delivery Range of repair Date for repair serviceperson signature Date of delivery Range of repair Date for repair serviceperson signature Date fitt or sale year month day Version of controller zlo Stamp installer or shop signture of installer know about using device present settings of controller and terms of guaranty date and signature of customer
9. l design Do not connect or group with other wires lt has a direct influence on the functioning of Figure 1 Figure 2 the key fob transmitter Fitting the RSC 2 radio controller Before starting to fit the controller it is recommended to pay Special attention to the proper connection of its power outputs CS Connect the power supply to the controller using female connectors inserted onto the output leads Solder the female connector or tighten the clamps on the wires of the controlled device It is recommended to follow the connection pattern closely to avoid damaging the controller 2 channel RSC 2 outputs connection side view Female connector Figure 3 Figure 4 Power support for RSC 2 controllers Fig 5 can be used for connecting You must NOT solder the wires to the output leads Soldering wires can cause controller damage and loss of warranty RSC 2 controllers have by standards male output connector leads which are powered with 12VDC voltage An example connection diagram is shown on Fig 6 and 7 Power support for RSC 2 controllers Description of the output leads of the support Red 0 75mm in diameter coupled wire 12VDC power supply Black with a red strap 0 75mm in diameter coupled wire negative power supply Two loose black wires 1 5mm in diameter outputs for channels 1 and 2 RSC 2 Power support Figure 5 Bulb or relay 1 channel 24V Bulb or relay 2 channel 24V 1 channel Bulb 1 2 chann
10. nsmitter Time registration in the monostable mode position in the configuration procedure To record the time for a selected channel in monostable mode press the selected push button on the key fob transmitter time recoding will begin LED 1 and the buzzer will turn on for the time of recording Pressing the same push button on the key fob transmitter again will finish time recording LED 1 and the buzzer will turn off double signaling by LED 1 and the buzzer indicates saving registered time in non volatile EEPROM memory Repeated pressing of the selected key fob transmitter push button will restart the time registration procedure In case of time registration for the next channel proceed as described above a If you wish to exit the configuration process disconnect the power supply of the K 2 programmer for at least 5 seconds b Press the D push button of the K 2 programmer for a short time to move to the first position in the configuration A schematic diagram of moving around the programming procedure is shown on page 17 2 Exitthe configuration procedure To exit the configuration procedure disconnect the power supply for at least 5 seconds All changes in the configuration will be saved automatically Turning on the power supply of the controller or a programmer together with the controller allows to check the functioning after making changes in the configuration While checking the operation of the controller do not press
11. r supply on or off BISTABLE DEPENDENT MODE Each press of the key fob transmitter push button switches on the negative power supply for selected channel with a simultaneous switch off of the negative power supply for another channel MONOSTABLE MODE Each press of the key fob transmitter push button switches on the negative power supply for selected channel at a previously programmed time MONOSTABLE DEPENDENT MODE Pressing the key fob transmitter push button switches on the negative power supply for selected channel at a previously programmed time with a simultaneous switch off of the negative power Supply for another channel if it was on at that time DYNAMIC CODE HOPPING Keelog KeeLog is a software data encoding system derived by Microchip Technology Inc used for safe and confidential transmission of controlling messages from the key fob transmitter to the controller The program contained in the key fob transmitter encrypts the data to prevent attempts of scanning and possible use of the information later It ensures safety of data transmission in relation to other users of the same system The encryption system is resistant to random and sabotage signals coming from other broadcasting devices which are jammed at the radio reception stage PROGRAMMING This function allows to modify controller settings logging erasing of key fob transmitters changing j the operation mode to bistable or monostable and the time setting G
12. ress the Assistant push button of the key fob transmitter to switch on the negative power supply onchannel 2 simultaneously Switching off the negative power supply on channel 1 The Main push button of the key fob transmitter erases the active channel Key fob transmitter Key fob transmitter Key fob transmitter Alien Ring Duet Main Functional push button push button Key fob transmitter Banan Assistant push button Key fob transmitter Lider Key fob transmitter Quartet Assistant 2 push button Functions of the key fob buttons working with RSC 2d Push button Main Push button Functional Push button Push button Assistant Assistant 2 switches on negative power supply switches on negative power supply on channel 1 switching off negative jon channel 2 switching off negative power supply on channel 2 Switches on negative power supply switches on negative power supply DUBANAING on channel 1 switching off negative lon channel 2 switching off negative power supply on channel 2 LIDER QUARTET power supply on channel 2 power supply on channel 1 power supply on channel 1 Switches on negative power supply switches on negative power supply on channel 1 switching off negative on channel 2 switching off negative power supply on channel 1 resets active channel resets channel 2 resets channel 1 Functions of the key fob buttons working with RSC 2e Pu
13. rom the controlled circuit c connect the programmer to the RSC 2 controller according to the numbering of outputs Before pressing the D push button check if LED 2 diode of the programmer is Sworn ire off LED 2 turned on makes it impossible to configure the RSC 2 controller lt To turn off the LED 2 in RSC 2e press the Functional push button on the key fob transmitter To turn off the LED 2 in RSC 2d and RSC 2f press the Main push button on the key fob transmitter While configuring between position 2 and 4 only logged key fob transmitters should be used in the RSC 2 controller 18 Configuration of the RSC 2 radio controller To enter configuration mode a Press and hold the push button of the K 2 programmer until LED 1 diode turns on and a Simultaneous sound signal occurs b When LED 1 diode has turned on in the K 2 programmer release the amp push button After entering configuration mode LED 1 of the K 2 programmer and the buzzer will turn on simultaneously every 3 seconds for 0 5 second which means that the programmer is at position in the configuration process Pressing any of the key fob transmitter buttons for the first time will cause its logging and deleting all key fob transmitters logged so far in the EEPROM memory of the RSC 2 controller Logging key fob transmitters position in the configuration process If you intend to logg a key fob transmitter press any key on the first key fob transmitt
14. sh button Main Switches on off negative power supply on channel 1 Switches on off negative power supply on channel 1 Switches on off negative power supply on channel 1 ALTEN DUET RING BANAN Push button Functional switches on off negative power supply on channel 2 Switches on off negative power supply on channel 2 Switches on off negative power supply on channel 2 Push button Push button Assistant Assistant 2 resets active channel resets channe 2 resets channel 1 Functions of the key fob buttons working with RSC 2f Push button Main resets active channel resets QUARTET active channel Push button Functional switches on negative power supply on channel 1 switching off negative power Supply on channel 2 Switches on negative power supply on channel 1 switching off negative power Supply on channel 2 Push button Assistant Switches on negative power supply on channel 2 switching off negative power Supply on channel 1 Switches on negative power supply on channel 2 switching off negative power Supply on channel 1 Description of RSC 2 controller outputs Antenn Control outputs ANENNA y No 30 channel 1 No 87 channel 2 Power inputs No 85 battery plus 12 VDC No 86 battery minus ground Antenna do not cut The wire antenna should be left free lying or RSC 2 viwed from hanging dependent on the fitting conditions the output side RSC 2 externa
15. the 4 push button of the programmer Only key fob transmitters logged in the controller should be used Factory settings of the controllers RSC 2d RSC 2e RSC 2f VJ Logged two key fob transmitters M monostable mode M time one secod 1 and 2 channel RD 24 voltage reducer Powering RSC 2 controllers with 24VDC RSC 2 controllers are to be powered with 12VDC however controlling elements can function in 24VDC installations To adjust RSC 2 controllers to 24VDC installation voltage reducer must be connected serially with the controller RD 24 is a simple circuit with current yield of 70 mA ensuring correct functioning of RSC 2 controllers while maintaining connection pattern compliant with the diagram Fig 10 In case of powering the controller with 24VDC the use of the voltage reducer is absolutely required The connection diagram must be followed to avoid controller damage RD 24 External design Figure 9 24 Channel 1 Bulb 1 Channel 2 Bulb 2 RSC 2 adjusted to 24V with the use of the RD 24 voltage reducer viewed from the RSC 2 output side Figure 10 Basic technical data Average range of key fob transmitters measured in open space and at low interference level 30 m 30 Average A23 battery type service life 6 do 12 month Recommended range of correct operation temperatures 20 do 60C Data encoding system KeeLog Microchip Technology Inc Data transmission frequency of key fob transmitters 433 92 MHz