Home

PocketScope User`s Manual

image

Contents

1. Charger or PocketScope Desk Charger obso lete with the Welch Allyn Convertible PocketScope handle and rechargeable battery 72600 Do not use the Universal Charger or PocketScope Desk Charger when using AA batteries 14 Batteries Recharging Batteries 72800 only 1 Plug charger into outlet Product No 71140 in the U S 120V 50 60 Hz Product No 71145 outside the U S specify country and voltage 2 To insure full charge and long lamp life turn instrument s to off position 3 Insert handle s into charger Green indicator lights will illuminate when handles are charging properly NOTE AA batteries will not charge and will not cause indicator lights to illuminate NOTE Only Welch Allyn rechargeable battery 72600 is approved for use with these handles 72600 Nickel Cadmium Rechargeable Battery Changing Batteries 1 Remove unscrew bottom cap 2 Tap handles on palm of hand until battery slides out 3 Insert new battery Rechargeable Insert in either direction AA cells Use alkaline cells for best per formance Insert positive end first for both cells AA Cells Recycling Batteries Welch Allyn now employs the services of an agency which can disassemble and recycle all components of nickel cadmium batteries so that nothing gets land filled or incinerated Should you wish to dispose of your expended Welch Allyn rechargeable battery via recycling
2. il retinoscopio estrarre la testa dello strumento Un apposito cilindro di focalizzazione consente di ruotare il fascio luminoso e di regolarne l ampiezza Oftalmoscopio p 8 Istruzioni per la regolazione della messa a fuoco Diottrie Ruotare il selettore della lente in senso orario A 6 ruotare nuovamente il selettore in senso orario quindi portare la multiplier lever sulla posizione Per le diottrie comprese tra 7 e 22 ruotare ancora il selettore in senso orario Diottrie Ruotare il selettore della lente in senso antio rario A 9 ruotare nuovamente il selettore in senso antio rario quindi portare la multiplier lever sulla posizione Per le diottrie comprese tra 10 e 25 continuare a ruotare il selettore in senso antiorario Instrucciones de funcionamiento de PocketScopes Le agradecemos su compra del SET PocketScope de WelchAllyn Aunque los mangos y las cabezas del instrumento son intercambiables se necesitan bombillas diferentes para las DISTINTAS cabezas del instrumento En los diagra mas se indica c mo cambiar de bombilla Otoscopio p 7 21131 cabeza de otoscopio normal bombilla 03400 21111 Otoscopio con iluminador de garganta bombilla 03400 Para convertir el otoscopio en un iluminador de la garganta s lo hay que desenroscar la cabeza del otoscopio Retinoscopio p 6 Para usar el retinoscopio tire primero de la cabeza hacia fu
3. in the U S and Canada only please send to Welch Allyn RECYCLE BATTERY 4341 State Street Road Skaneateles Falls NY 13153 0220 Welch Allyn Canada RECYCLE BATTERY 160 Matheson Blvd East Mississauga Ontario CANADA L4Z 1V4 For locations outside the U S and Canada consult your local recycling authority for correct disposal of batteries Cleaning Recommendations Ophthalmoscopes Cleaning and repair should be performed at Welch Allyn DO NOT apply alcohol to mirror or lenses as this may degrade optical quality Otoscope Retinoscope Transilluminator Do not use abrasive cleaners alcohol or other 16 chemicals Lens may be cleaned with warm water and soap Handle The PocketScope handle wipes clean with a damp cloth Desk Wall Charger DO NOT pour water or any cleaning solution into charging wells DO NOT autoclave Desk Wall Charger instruments or handles Replacement Parts To order replacement parts use these numbers No 08400 Retinoscope Lamp No 03900 Ophthalmoscope Lamp No 03400 Otoscope Transilluminator Lamp No 13000 Ophthalmoscope without handle No 16210 Retinoscope without handle No 42000 Transilluminator without handle No 21111 Otoscope Throat Illuminator without handle No 21130 Otoscope without handle No 211024 501 Lamp and shroud assembly No 211005 Otoscope Lens No 21504 Insufflator No 72800 PocketScope Convertible Handle with 72600 Rechargeable Batte
4. AAA WelchAllyn PocketScopes Operating Instruction Manual Transilluminator Thank you for purchasing the Welch Allyn Halogen PocketScope Set The operating and maintenance instructions found in this manual are for both the Ophthalmic and Diagnostic model sets They should be followed to ensure many years of accurate and reliable service Please read these instructions thoroughly before using your PocketScope Note While the handles and instrument heads of the PocketScopes are interchangeable differ ent lamps are required for different instrument heads For the retinoscope use lamp No 08400 for the ophthalmoscope No 03900 and for the otoscope throat illuminator and transil luminator lamp No 03400 For guaranteed performance use genuine Welch Allyn lamps only Mode d emploi des PocketScopes Merci d avoir achet un jeu de PocketScope WelchAllyn A la diff rence des poign es et des t tes qui sont inter changeables les lampes utiliser sont sp cifiques chaque t te d instrument Veuillez consulter les dia grammes pour savoir comment remplacer les diff rentes lampes Otoscope p 7 21131 T te d otoscope standard lampe 03400 21111 Otoscope avec source lumineuse pour la gorge lampe 03400 Pour convertir l otoscope en source lumineuse pour la gorge il suffit de d visser la t te de l otoscope R tinoscope p 6 Pour utiliser le r tinoscope d ploye
5. diopters 4 Multiplier Lever Allows fast movement through the range via 16 diopter shifts When used with lens selection dial allows single diopter steps through 48 lens combinations Two position filter switch Engage either open or red free filter Larger spot size for wider field of view Sealed optics Diopter Display Window Displays direct reading of diopter values positive values displayed in green negative values dis played in red OND al Lens Instructions To move through the range on the plus side Rotate lens selection dial in positive clockwise direction At 6 diopters move lens dial clockwise again Then move multipli er lever to position Continue moving lens dial in same clockwise direction to access 7 thru 22 diopters 8 To move through the range on the negative gt side Rotate lens selection dial in negative counter clockwise direction At 9 diopters move lens dial counterclockwise again Then move multiplier lever to position Continue moving lens dial in same counterclockwise direction to access 10 to 25 diopters Practitioner Side Rubber brow rest Lens selection dial Lens multiplier Diopter display window Filter Red Free Filter position Two position Filter switch Open spot position Aperture selection dial PocketScope Transilluminator Transilluminator Features e Fiber Optic tra
6. era para que salga como un telescopio El manguito de enfoque permite enfocar y hacer girar la FRANJA Oftalmoscopio p 8 Instrucciones para la lente Dioptr as Gire el dial de la lente en sentido horario A 6 mueva otra vez el dial de la lente en sentido horario luego mueva la multiplier lever a la posici n Vuelva a mover el dial de la lente en sentido horario para 7 a 22 Dioptrias Gire el dial de la lente en sentido antiho rario A 9 mueva otra vez el dial de la lente en sentido antihorario Luego mueva la multiplier lever a la posici n Siga moviendo el dial de la lente en sentido antiho rario para 10 a 25 PocketScope Retinoscope Retinoscope Features 6 PocketScope Otoscope Throat lluminator ce ooo 7 PocketScope Ophthalmoscope OphthalMOsCop ssasese rires 8 Ophthalmoscope Lens Instructions 8 9 PocketScope Transilluminator Transilluminator Features 10 Transilluminator Attachment 10 Lamp Replacement Retinoscope Lamp Replacement Otoscope Lamp Replacement Ophthalmoscope Lamp Replacement Transilluminator Lamp Replacement PocketScope Handles AA Battery Handle ss 13 Convertible Handle AA amp Rechargeable 14 Batteries Recharging Batteries 15 Changing Batteries pp 15 16 Cleaning Recommendations 16 17 Replacemen
7. nsmission for bright cool light transmission e Curved design to fit into tight areas Transilluminator Attachment Remove the retinoscope by turning the instru ment in a counterclockwise direction This will disconnect the retinoscope Connect the transilluminator by turning the instrument in a clockwise direction Light pipe can be rotated to locate optimum orientation Instructions for attaching the transilluminator Lamp Replacement Retinoscope Lamp Replacement 1 Remove unscrew retinoscope head 2 Grasp end of lamp and pull out use nail file or similar object if neces sary 10 3 Insert replacement lamp by carefully aligning pin on lamp shaft with slot in retinoscope Push lamp in until firmly seated Otoscope Lamp Replacement 21111 only 1 Remove unscrew otoscope head 2 Unscrew lamp holder in counterclockwise direction and remove from handle 3 Grasp end of lamp and pull out of holder 4 Insert new lamp by reversing above process NOTE If lamp surface is touched or becomes smudged wipe clean with a soft cloth This will assure longer lamp life and higher output Ophthalmoscope Lamp Replacement 1 Unscrew ophthalmoscope head in counter clockwise direction 2 Grasp end of lamp and pull out use nail file or similar object if necessary 3 Insert replacement lamp by carefully PocketScope Handles aligning pin on lamp shaft with slot in ophthalmo
8. rsion des Otoskops in einen Halsbeleuchter wird einfach der Otoskopkopf aufgeschraubt Skiaskop p 6 Zur Verwendung des Skiaskops dieses zun chst teleskopisch auseinander ziehen indem der Kopf nach au en gezogen wird Ein Brennpunktaufsatz erm glicht die Scharfeinstellung und Rotation des Streifens Ophthalmoskop p 8 Linsenanleitung Dioptrie Die Linsenscheibe im Uhrzeigersinn drehen Bei 6 die Linsenscheibe wiederum im Uhrzeigersinn drehen und dann den Multiplier Lever in die Position stellen Die Linsenscheibe dann wieder im Uhrzeigersinn f r 7 bis 22 drehen Dioptrie Die Linsenscheibe gegen den Uhrzeigersinn drehen Bei 9 die Linsenscheibe wiederum gegen den Uhrzeigersinn drehen Danach den Multiplier Lever in die Position stellen Die Linsenscheibe dann weiter f r 10 bis 25 gegen den Uhrzeigersinn drehen Grazie per avere acquistato un set PocketScope WelchAllyn Le impugnature e le teste degli strumenti sono intercam biabili tuttavia le teste degli strumenti richiedono l uso di lampadine diverse Per la sostituzione delle lampadine fare riferimento alle figure riportate qui di seguito Otoscopio p 7 21131 Testa standard per otoscopio lampadina 03400 21111 Otoscopio con illuminatore laringeo lampadina 03400 Per convertire l otoscopio in illuminatore laringeo basta svitare la testa dell otoscopio Retinoscopio p 6 Per usare
9. ry No 72801 PocketScope Convertible Handle without battery 17 No 72830 No 72831 No 72837 No 72860 Domestic No 72865 International specify country No 72600 No 24400 No 24420 No 52432 No 52434 PocketScope AA Handle with Alkaline Batteries PocketScope AA Handle without batteries Upgrade kit to convertible handle bottom cap amp rechargeable battery Upgrade kit to convertible handle bottom cap rechargeable battery amp Universal Charger Upgrade kit to convertible handle bottom cap rechargeable battery amp Universal Charger Replacement nickel cadmium 2 5v rechargeable battery Set of 4 reusable polypropy lene specula 2 3 4 5mm Set of 3 reusable SofSpec Specula 3 5 7mm Disposable specula box of 1000 2 5mm pediatric size Disposable specula box of 1000 4mm regular size For repairs send unit to Welch Allyn Inc Service Department 4341 State Street Road Skaneateles Falls NY 13153 0220 Printed in U S A Part No PM130023 4 D
10. scope head Push lamp in until AA PocketScope Handles 72830 firmly seated 1 This handle accepts any brand of AA batter NOTE If lamp surface is touched or becomes ies Use alkaline batteries for best perfmance smudged wipe clean with a soft cloth This 2 The AA handle can be upgraded to a con will assure longer lamp life and higher output vertible handle which allows the handle Align pin to slot in ophthalmoscope to be used with AA batteries Welch Allyn rechargeable batteries and the Universal Charger or PocketScope Desk Charger obsolete The upgrade kit part number 72837 includes the rechargeable bottom cap 72810 plus the rechargeable battery 72600 The upgrade kit part number 72860 or 72865 includes the rechargeable bottom cap rechargeable battery and the 7114X head AZ Universal Charger with Pocketscope Adapters Transilluminator Lamp Replacement 1 12 Place thumb on Grasp end of lamp knurled ring at base of instrument Unscrew transillumi nator in a counter clockwise direction and pull out use nail file or similar object if needed Insert replacement lamp No 03400 Push lamp in firmly 13 Convertible PocketScope Handles 72800 For use with AA and Welch Allyn rechargeable batteries This handle can be used with either AA batteries or with Welch Allyn s PocketScope rechargeable battery 72600 and Desk Charger NOTE Only use the Welch Allyn Universal
11. t Parts 17 18 PocketScope Retinoscope Retinoscope Features External focusing sleeve allows for easy adjustment regardless of what size hand or how instrument is held Continuous 360P rotation Dust free optics to keep instrument clean longer Fixation cards that easily attach for use during dynamic retinoscopy Collapsible head for compact size Patents US 5 189 449 and 5 459 535 NOTE The retinoscope must be telescoped out by pulling in an outward direction The retinoscope can only be used if this opera tion is performed Patient Side Practitioner Side Rubber A brow rest Dust free 0 optics E A un we Focusing PocketScope Otoscope Throat Illuminator 21111 only To convert otoscope to throat illuminator unscrew otoscope head in counterclockwise direction NOTE Illuminator section can become hot Avoid more than momentary direct skin contact To turn instruments on and off and vary intensity rotate switch at base of instrument head As intensity increases green band gets thicker On Off Rheostat Switch PocketScope Ophthalmoscope 1 Rubber Brow Rest 2 Aperture selection dial with continuous rotation Allows access to microspot small large fixation slit and cobalt blue 3 Lens Selection Dial When used with multiplier lever allows single diopter steps through 48 lens combinations from 22 to 25
12. z l appareil en tirant la t te vers l ext rieur Le manchon de mise au point permet d effectuer la mise au point et la rotation des stries Ophtalmoscope p 8 Instructions relatives aux lentilles Dioptries Faites pivoter le cadran de la lentille dans le sens horaire 6 faites de nouveau tourner le cadran de la lentille dans le sens horaire puis placez le multiplier lever sur la position Faites de nouveau pivoter le cad ran de la lentille dans le sens horaire si vous souhaitez atteindre les param tres 7 22 Dioptries Faites pivoter le cadran de la lentille dans le sens horaire inverse 9 faites de nouveau tourner le cadran de la lentille dans le sens horaire inverse Placez ensuite le multiplier lever sur la position Continuez faire pivoter le cadran de la lentille dans le sens horaire inverse si vous souhaitez atteindre les param tres 10 25 Bedienungsanleitung f r PocketScopes Istruzioni d uso del PocketScopes Wir bedanken uns f r Ihren Kauf eines PocketScope Satzes von WelchAllyn Obwohl die Griffe und Instrumentenk pfe untereinander austauschbar sind werden f r die verschiedenen Instrumentenk pfe verschiedene Lampen ben tigt Der Lampenaustausch ist auf den diagrammatischen Abbildungen angezeigt Otoskop p 7 21131 standardm iger Otoskopkopf Lampe 03400 21111 Otoskop mit Halsbeleuchter Lampe 03400 Zur Konve

Download Pdf Manuals

image

Related Search

Related Contents

Paskacheval  Danby DDW1809W Dishwasher User Manual  T賞 O賞 D賞 A1賞 D賞 A1賞 Y賞 T賞 O賞 Y賞  RV-10DX  MODE D`EMPLOI CHEQUES SPORT 2014-2015  Watlow PM Express Manual - Seagate Control Systems  Panasonic AK-HC930 Menu Information  FRANÇAIS MANUEL D`UTILISATION ET D`ENTRETIEN DEUTSCH  ACTUALIZACIÓN SISTEMA SIAHV VERSION 2  