USER`S MANUAL TABLE OF CONTENTS FIRE

image

Contents

1. 00 0 cece eee 5 Troubleshooting Guide cccisssce etc eden ene eee Reed ean ennend 6 Limited Warranty 000s cece eee eee eee eel 6 2007 BRK Brands Inc a Jarden Corporation company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved Consumer Affairs 800 323 9005 www brkelectronics com www firstalert com INTRODUCTION BASIC SAFETY INFORMATION IMPORTANT e Dangers Warnings and Cautions alert you to important operating instructions or to potentially hazardous situations Pay special attention to these items e THIS IS NOT A SMOKE ALARM This CO Alarm is designed to detect carbon monoxide from ANY source of combustion It is NOT designed to detect smoke fire or any other gas e This CO Alarm is approved for use in single family residences It is NOT designed for marine use ACAUTION e This CO Alarm will only indicate the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas AWARNING e The Silence Feature is for your convenience only and will not correct a CO problem Always check your home for a potential problem after any alarm Failure to do so can result in injury or death e NEVER ignore your Carbon Monoxide Alarm if it alarms Refer to If Your CO Alarm Sounds for more information Failure to do so can result in injury or death e Test the CO Alarm once a week If the CO Alarm ever fails to test correctly have it
2. WARNING Test units used in RVs after the vehicle has been in storage before every trip and once a week while in use Failure to test units used in RVs as described may remove your protection REQUIRED To RECOMMENDED SMOKE ALARMS INTERCONNECTED AGENCY PLACEMENT RECOMMENDATIONS NFPA 72 National Fire Code Chapter 11 For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station Smoke Alarms shall be installed as follows 1 In all sleeping rooms Exception Smoke Alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved Smoke Alarms powered by batteries are permitted A 11 8 3 Are More Smoke Alarms Desirable The required number of Smoke Alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required Smoke Alarms For this reason it is recommended that the householder consider the use of additional Smoke Alarms for those areas for increased protection The add
3. button The Alarm remains functional The LED will flash every 10 seconds for up to 10 minutes to remind you the alarm has been silenced The flashing LED will stop when the unit returns to normal operation AWARNING The Silence Feature does not disable the unit it makes it temporarily less sensitive to smoke For your safety if smoke around the unit is dense enough to suggest a potentially dangerous situation it will stay in alarm or may re alarm quickly If you do not know the source of the smoke do not assume it is an unwanted alarm Not responding to an alarm can result in property loss injury or death IF YOU SUSPECT A PROBLEM Smoke Alarms may not operate properly because of dead missing or weak batteries a build up of dirt dust or grease on the Smoke Alarm cover or installation in an improper location Clean the Smoke Alarm as described in Regular Maintenance and install a fresh battery then test the Smoke Alarm again If it fails to test properly when you use the test button or if the problem persists replace the Smoke Alarm immediately e If you hear a chirp once a minute replace the battery e If you experience frequent non emergency alarms like those caused by cooking smoke try relocating the Smoke Alarm e Ifthe alarm sounds when no smoke is visible try cleaning or relocating the Smoke Alarm The cover may be dirty e Ifthe alarm does not sound during testing try installing a new battery
4. Never leave anything cooking on the stove unattended 7 Keep portable heaters and open flames like candles away from flammable materials 8 Don t let rubbish accumulate Keep alarms clean and test them weekly Replace alarms immediately if they are not working properly Smoke Alarms that do not work cannot alert you to a fire Keep at least one working fire extinguisher on every floor and an additional one in the kitchen Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked AWTERTE Models fa SA300 UL STANDARD 217 SA303 US SA305 Lister BEFORE YOU INSTALL THIS SMOKE ALARM IMPORTANT Read Recommended Locations for Smoke Alarms and Locations to Avoid for Smoke Alarms before beginning This unit mon itors the air and when smoke reaches its sensing chamber it alarms It can give you more time to escape before fire spreads This unit can ONLY give an early warning of developing fires if it is installed main tained and located where smoke can reach it and where all residents can hear it as described in this manual This unit will not sense gas heat or flame It cannot prevent or extinguish fires Understand The Different Type of Smoke Alarms Battery powered or electrical Different Smoke Alarms provide different types of protection See About Smoke Alarms for details Know Where To Install Your Smoke Alarms Fire Safety Professionals recomme
5. and make sure it is snapped in securely Do not try fixing the alarm yourself this will void your warranty If the Smoke Alarm is still not operating properly and it is still under warranty please see How to Obtain Warranty Service in the Limited Warranty below LIMITED WARRANTY BRK Brands Inc BRK the maker of First Alert brand products warrants that for a period of ten years from the date of purchase this product will be free from defects in material and workmanship BRK at its option will repair or replace this product or any component of the product found to be defective during the warranty period Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value This is your exclusive warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable Keep the original sales receipt Proof of purchase is required to obtain warranty performance BRK dealers service centers or retail stores selling BRK products do not have the right to alter modify or any way change the terms and conditions of this warranty This warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions disas
6. fire detection systems in places housing many people like apartment buildings condominiums hotels motels dormitories hospitals long term health care facilities nursing homes day care facilities or group homes of any kind even if they were once single family homes It is not a suitable substitute for complete fire detection systems in warehouses industrial facilities commercial buildings and special purpose non resi dential buildings which require special fire detection and alarm systems Depending on the building codes in your area this Smoke Alarm may be used to provide additional protection in these facilities The following information applies to all four building types below In new construction most building codes require the use of AC or AC DC powered Smoke Alarms only In existing construction AC AC DC or DC powered Smoke Alarms can be used as specified by local building codes Refer to NFPA 101 Life Safety Code or NFPA 72 National Fire Alarm Code local building codes or consult your Fire Department for detailed fire protection requirements in buildings not defined as house holds 1 Single Family Residence Single family home townhouse It is recommended Smoke Alarms be installed on every level of the home in every bedroom and in each bedroom hallway 2 Multi Family or Mixed Occupant Residence Apartment building condominium This Smoke Alarm is suitable for use in individual apartments or co
7. important to test this unit every week to make sure it is working properly Using the test button is the recommended way to test this Smoke Alarm Press and hold the test button on the cover of the unit until the alarm sounds the unit may continue to alarm for a few seconds after you release the button If it does not alarm make sure the unit is receiving power and test it again If it still does not alarm replace it immediately During testing you will hear a loud repeating horn pattern 3 beeps pause 3 beeps pause REGULAR MAINTENANCE This unit has been designed to be as maintenance free as possible but there are a few simple things you must do to keep it working properly AWARNING Use only the replacement batteries listed below The unit may not operate properly with other batteries Never use rechargeable batteries since they may not provide a constant charge e Test it at least once a week e Clean the Smoke Alarm at least once a month gently vacuum the outside of the Smoke Alarm using your household vacuum s soft brush attachment A can of clean compressed air sold at computer or office supply stores may also be used Follow manufacturer instructions for use Test the Smoke Alarm Never use water cleaners or solvents since they may damage the unit e f the Smoke Alarm becomes contaminated by excessive dirt dust and or grime and cannot be cleaned to avoid unwanted alarms replace the unit immediately e Relocate t
8. purpose units like those with visual and audible alarms should be installed for hearing impaired residents Smoke Alarms may not have time to alarm before the fire itself causes damage injury or death since smoke from some fires may not reach the unit immediately Examples of this include persons smoking in bed children playing with matches or fires caused by violent explosions resulting from escaping gas Smoke Alarms are not foolproof Like any electronic device Smoke Alarms are made of components that can wear out or fail at any time You must test the unit weekly to ensure your continued protection Smoke Alarms cannot prevent or extinguish fires They are not a substitute for property or life insurance Smoke Alarms have a limited life The unit should be replaced immediately if it is not operating properly You should always replace a Smoke Alarm after 10 years from date of purchase Write the purchase date on the space provided on back of unit First Alert is a registered trademark of the First Alert Trust Printed in Mexico M08 0067 004 J1 03 07 First Alert USER S MANUAL BATTERY OPERATED CARBON MONOXIDE ALARM WITH SILENCE FEATURE WNTERTE Model gj C0400 us ListeD MPORTANT l PLEASE READ CAREFULLY AND SAVE Printed in Mexico M08 0140 004 P 06 07 This user s manual contains important information about your Carbon Monoxide CO Alarm s operation If you are installing this CO Alarm for use b
9. that of merchantability or fitness for any particular purpose with respect to battery Model SA305 Smoke Alarm Purchased with Lithium Battery BRK Brands Inc warrants the enclosed battery to be free from defects in materials and workmanship under normal use and service for a period of ten years from the date of purchase RECOMMENDED LOCATIONS FOR SMOKE ALARMS Installing Smoke Alarms in Single Family Residences The National Fire Protection Association NFPA recommends one Smoke Alarm on every floor in every sleeping area and in every bed room In new construction the Smoke Alarms must be AC powered and interconnected See Agency Placement Recommendations for details For additional coverage it is recommended that you install a Smoke Alarm in all rooms halls storage areas finished attics and basements where temperatures normally remain between 40 F 4 C and 100 F 38 C Make sure no door or other obstruction could keep smoke from reaching the Smoke Alarms More specifically install Smoke Alarms e On every level of your home including finished attics and basements e Inside every bedroom especially if people sleep with doors closed e In the hall near every sleeping area If your home has multiple sleep ing areas install a unit in each If a hall is over 40 feet 12 meters long install an alarm at each end e At the top of the first to second floor stairway and at bottom of basement stairway IMPORTA
10. ACAUTION e Do not install this unit over an electrical junction box Air cur rents around junction boxes can prevent smoke from reaching the sensing chamber and prevent the unit from alarming Only AG powered units are intended for installation over junction OXes Do not stand too close to the unit when the alarm is sounding It is loud to wake you in an emergency Exposure to the horn at close range may harm your hearing Do not paint over the unit Paint may clog the openings to the sensing chamber and prevent the unit from operating properly HOW TO INSTALL THIS SMOKE ALARM THE PARTS OF THIS SMOKE ALARM Alarm Base 1 Battery Compartment 2 Test button Model SA300 2 Test Silence button Models SA303 and SA305 This unit is designed to be mounted on 2 the ceiling or on the wall if necessary AWARNING DO NOT attach this Alarm to an electrical junction box Attachment to an electrical box may impair the Alarm s operation Attach directly to wallboard or flat wall or ceiling surface The Parts of This Unit 1 Mounting Bracket 2 Mounting Slots and Screws 3 Locking Pins break out of bracket 4 Latch to Open Battery Compartment 5 Swing Out Battery Compartment To remove the mounting bracket from the Smoke Alarm base hold the Smoke Alarm base firmly and twist the mounting bracket counterclockwise FOLLOW THESE SIMPLE STEPS Tools you will need e Pencil e Drill with 3 16 5 mm
11. M BEDROOM BEDROOM KITCHEN GARAGE LIVING ROOM HALL z amp R r l BASEMENT O REQUIRED TO MEET NFPA RECOMMENDATIONS SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS In a Single level Home e Install at least one CO Alarm near or within each separate sleeping area e For added protection install an additional CO Alarm at least 20 feet 6 meters away from the furnace or fuel burning heat source In a Multi level Home e Install at least one CO Alarm near or within each separate sleeping area e For added protection install at least one CO Alarm on each level of the home e For added protection install an additional CO Alarm at least 20 feet 6 meters away from the furnace or fuel burning heat source In Mobile Homes e Install CO Alarms on inside walls ONLY Uninsulated outside walls and roofs of mobile homes often transfer heat and cold from outdoors The Alarm should be located at least 152 mm 6 inches from all exterior walls and at least 305 mm 12 inches from supply or return vents WHERE CO ALARMS SHOULD NOT BE INSTALLED DO NOT LOCATE THIS CO ALARM e In garages kitchens furnace rooms or in any extremely dusty dirty or greasy areas e Within 5 feet 1 5 meters of any cooking appliance e In extremely humid areas This alarm should be at least 10 feet 8 meters from a bath or shower sauna humidifier vaporizer dishwasher laundry room utility room or other sou
12. NT Specific requirements for Smoke Alarm installation vary from state to state and from region to region Check with your local Fire Department for current requirements in your area It is recommended AC or AC DC units be interconnected for added protection BEDROOM KITCHEN DINING ROOM es HALL BS Oo A O So O O LIVING ROOM SINGLE STORY RESIDENCE APARTMENT MOBILE HOME MULTI STORY RESIDENCE EXISTING HOMES KEY REQUIRED TO Q RECOMMENDED A SMOKE ALARMS WITH SILENCE MEET NFPA FOR ADDITIONAL FEATURES RECOMMENDED FOR RECOMMENDATIONS PROTECTION ADDITIONAL PROTECTION 1 BEDROOM HALLE BEDROOM e e ja o BEDROOM KITCHEN DINING ROOM ej Q Eo 1 Tr LIVING ROOM FINISHED BASEMENT SINGLE STORY RESIDENCE APARTMENT MOBILE HOME MULTI STORY RESIDENCE KEY NEW CONSTRUCTION MEET NFPA FOR ADDITIONAL WTA SENCE AC OR ACIDE PROTECTION RECOMMENDATIONS Cea ee DED FOR ADDITIONAL PROTECTION INSTALLING SMOKE ALARMS IN MOBILE HOMES amp RVS For minimum security install one Smoke Alarm as close to each sleeping area as possible For more security put one unit in each room Many older mobile homes especially those built before 1978 have little or no insulation If your mobile home is not well insulated or if you are unsure of the amount of insulation it is important to install units on inside walls only Smoke Alarms should be installed where temperatures normally remain between 40 F 4 C and 100 F 38 C
13. PROTECT MY FAMILY A CO Alarm is an excellent means of protection It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average healthy adults ACO Alarm is not a substitute for proper maintenance of home appliances To help prevent CO problems and reduce the risk of CO poisoning e Clean chimneys and flues yearly Keep them free of debris leaves and nests for proper air flow Also have a professional check for rust and corrosion cracks or separations These conditions can prevent proper air movement and cause backdrafting Never cap or cover a chimney in any way that would block air flow e Test and maintain all fuel burning equipment annually Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee e Make regular visual inspections of all fuel burning appliances Check appli ances for excessive rust and scaling Also check the flame on the burner and pilot lights The flame should be blue A yellow flame means fuel is not being burned completely and CO may be present Keep the blower door on the furnace closed Use vents or fans when they are available on all fuel burning appliances Make sure appliances are vented to the outside Do not grill or barbecue indoors or in garages or on screen porches e Check for exhaust backflow from CO sources Check the draft hood on an operating furnace for a backdraft Look for cracks on furnace heat excha
14. USER S MANUAL SMOKE ALARM Model SA300 Model SA303 and Model SA305 With Silence Feature IMPORTANT PLEASE READ CAREFULLY AND SAVE This user s manual contains important information about your Smoke Alarm s operation If you are installing this Smoke Alarm for use by others you must leave this manual or a copy of it with the end user Printed in Mexico M08 0067 004 J1 03 07 TABLE OF CONTENTS Fire Safety Tips sssri srpen eee eee eee eee eee eee eee 1 Before You Install This Smoke Alarm 0000 e cece ee eee eee 1 How To Install This Smoke Alarm 00 0 cece ee eee eee 2 Optional Locking Features 000 cece eee eee eee 2 Weekly Testing eesin 00 ccs e cece eee eee eee eee ees 3 Regular Maintenance 0 0c eee e eee eee eee eee 3 If This Smoke Alarm Sounds 0000e cece e eee e eee eee 3 What To Do In Case Of Fire 0 cece eee eee 3 Using the Silence Feature Models SA303 SA305 Only 3 If You Suspect A Problem 0000 e cece eee eee eee 3 Limited Warranty 0c cc cence eee eee 3 Recommended Locations For Smoke Alarms 20000 4 Locations To Avoid For Smoke Alarms 020eeeeeeeeeee 4 About Smoke Alarms 0000 cece eee eee eee eee 5 Special Compliance Considerations 00eceee eee e eee 5 Limitations Of Smoke Alarms 02000 cece cece eee eens 5 2007 BRK Brands Inc a subsidiary of Jarden Corporation 3901 Liberty Street Roa
15. alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet 3 meters However if the CO Alarm is installed outside the bedroom it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages This is especially true if the door is closed or only partly open Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors Noise from traffic stereo radio television air conditioner or other appliances may also prevent alert persons from hearing the alarm horn This CO Alarm is not intended for people who are hearing impaired CO Alarms are not a substitute for a smoke alarm Although fire is a source of carbon monoxide this CO Alarm does not sense smoke or fire This CO Alarm senses CO that may be escaping unnoticed from malfunctioning furnaces appliances or other sources Early warning of fire requires the installation of smoke alarms CO Alarms are not a substitute for life insurance Though these CO Alarms warn against increasing CO levels BRK Brands Inc does not warrant or imply in any way that they will protect lives from CO poisoning Homeowners and renters must still insure their lives CO Alarms have a limited life Although the CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible any of these parts could fail at any time Therefore you must test your CO Alarm week
16. arm horn and the Red light is flashing move everyone to a source of fresh air DO NOT disconnect the batteries from the CO Alarm AWARNING Alarms have various limitations See General Limitations of CO Alarms for details USING THE SILENCE FEATURE AWARNING e The Silence Feature is for your convenience only and will not correct a CO problem Always check your home for a potential problem after any alarm Failure to do so can result in injury or death e NEVER remove the batteries from your CO Alarm to silence the horn Use the silence feature Removing the batteries removes your protection See If Your CO Alarm Sounds for details on responding to an alarm The Silence Feature is intended to temporarily silence your CO Alarm s alarm horn while you correct the problem it will not correct a CO problem While the alarm is silenced it will continue to monitor the air for CO When CO reaches alarm levels the alarm will sound repeating horn pattern 4 beeps a pause 4 beeps etc Press and hold the Test Silence button until the horn is silent The initial Silence cycle will last approximately 4 minutes NOTE After initial 4 minute Silence cycle the CO Alarm re evaluates present CO levels and responds accordingly If CO levels remain potentially danger ous or start rising higher the horn will start sounding again While the detector is silenced If the CO Alarm Is silent for only 4 minutes then This
17. ath e Never remove the batteries from a battery operated Smoke Alarm to stop an unwanted alarm caused by cooking smoke etc Removing batteries disables the alarm so it cannot sense smoke and removes your protection Instead open a window or fan the smoke away from the unit The alarm will reset automatically e Ifthe unit alarms get everyone out of the house immediately WHAT TO DO IN CASE OF FIRE e Don t panic stay calm Follow your family escape plan e Get out of the house as quickly as possible Don t stop to get dressed or collect anything e Feel doors with the back of your hand before opening them If a door is cool open it slowly Don t open a hot door Keep doors and windows closed unless you must escape through them e Cover your nose and mouth with a cloth preferably damp Take short shallow breaths e Meet at your planned meeting place outside your home and do a head count to make sure everybody got out safely e Call the Fire Department as soon as possible from outside Give your address then your name e Never go back inside a burning building for any reason e Contact your Fire Department for ideas on making your home safer AWARNING Alarms have various limitations See Limitations of Smoke Alarms for details USING THE SILENCE FEATURE MODELS SA303 SA305 ONLY The Silence Feature can temporarily quiet an unwanted alarm for up to 10 minutes To use this feature press the Test Silence
18. atteries that are included with this unit BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty Some states provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province How to Obtain Warranty Service Service If service is required do not return the product to your retailer In order to obtain warranty service contact the Consumer Affairs Division at 1 800 323 9005 7 30 AM to 5 00 PM Central Standard Time Monday through Friday To assist in serving you please have the model number and date of purchase available when calling For Warranty Service return to 25 Spur Drive El Paso TX 79906 Battery BRK Brands Inc makes no warranty express or implied written or oral including that of merchantability or fitness for any particular purpose with respect to battery For your records please record Replacement date is five years after installation Date Purchased Where Purchased 4 Month Y
19. cannot be answered by reading this manual call Consumer Affairs at 1 800 323 9005 LIMITED WARRANTY BRK Brands Inc BRK the maker of BRK brand and First Alert brand products warrants that for a period of five years from the date of purchase this product will be free from defects in material and workmanship BRK at its option will repair or replace this product or any component of the product found to be defective during the warranty period Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value This is your exclusive warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable Keep the original sales receipt Proof of purchase is required to obtain warranty performance BRK dealers service centers or retail stores selling BRK products do not have the right to alter modify or any way change the terms and conditions of this warranty This warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions disassembly repair or alteration by anyone other than BRK or an authorized service center Further the warranty does not cover acts of God such as fire flood hurricanes and tornadoes or any b
20. cessary to activate the locks in single family households where unauthorized battery or Alarm removal is not a concern These Smoke Alarms have two separate locking features one to lock the battery compartment and the other to lock the Smoke Alarm to the mounting bracket You can choose to use either feature independently or use them both Locking Pin Tools you will need Needle nose pliers or utility knife Standard Flathead screwdriver Both locking features use locking pins which are molded into the mounting bracket Using needle nose pliers or a utility knife remove one or both pins from the mounting bracket depending on how many locking features you want to use IMPORTANT s To permanently remove either lock insert a flathead screwdriver between the locking pin and the lock and pry the pin out of the lock TO LOCK THE BATTERY COMPARTMENT Do not lock the battery compartment until you have installed the battery and tested the unit 1 Push and hold test button until the alarm sounds 3 beeps pause 3 beeps pause IMPORTANT If the unit does not alarm during testing DO NOT lock the battery compartment Install a new battery and test again If the Smoke Alarm still does not alarm replace it immediately 2 Using needle nose pliers or a utility knife detach one locking pin from the mounting bracket Push the locking pin through the hole near the battery drawer on the back of the Smoke Alarm Using need
21. d Aurora IL 60504 8122 All rights reserved Consumer Affairs 800 323 9005 e www firstalert com All First Alert Smoke Alarms conform to regulatory requirements including UL217 and are designed to detect particles of combustion Smoke particles of varying number and size are produced in all fires ex lonization technology is generally more sensitive than photoelectric 1 technology at detecting small particles which tend to be produced in greater amounts by flaming fires which consume combustible materials rapidly and spread quickly Sources of these fires may include paper burning in a wastebasket or a grease fire in the kitchen Photoelectric technology is generally more sensitive than ionization P technology at detecting large particles which tend to be produced in greater amounts by smoldering fires which may smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches or bedding For maximum protection use both types of Smoke Alarms on each level and in every bedroom of your home FIRE SAFETY TIPS Follow safety rules and prevent hazardous situations 1 Use smoking materials properly Never smoke in bed 2 Keep matches or lighters away from children 3 Store flammable materials in proper containers 4 Keep electrical appliances in good condition and don t overload elec trical circuits 5 Keep stoves barbecue grills fireplaces and chimneys grease and debris free 6
22. drill bit e Hammer e Standard Flathead screwdriver Remove the mounting bracket from the Smoke Alarm base Hold the mounting bracket against the ceiling or wall and make a mark at the center of each of the mounting slots with a pencil Put the unit where it won t get covered with dust when you drill the mounting holes Using a 3 16 5 mm drill bit drill a hole through each pencil mark Insert the plastic screw anchors in the plastic bag with screws into the holes Tap the screw anchors gently with a hammer if necessary until they are flush with the ceiling or wall Tighten the screws provided into the screw anchors 6 Activate the battery With the battery compartment open install the battery so the terminals on the battery match the terminals on the Smoke Alarm Match to and to Push the battery in until it snaps in securely and cannot be shaken loose If the battery is not snapped in completely the unit cannot receive battery power The Smoke Alarm may beep briefly when you install the battery this is normal Position the base of the Smoke Alarm over the mounting bracket and turn The Alarm can be positioned over the bracket every 60 Turn the Smoke Alarm clockwise right until the unit is in place Test the Smoke Alarm See Weekly Testing OPTIONAL LOCKING FEATURES The locking features are designed to discourage unauthorized removal of the battery or Alarm It is not ne
23. e button on the cover until the LED flashes The alarm horn will sound 4 beeps a pause then 4 beeps The ALARM RED light will flash The alarm sequence should last 5 6 seconds If it does not alarm make sure fresh batteries are correctly installed and test it again If the unit still does not alarm replace it immediately If the alarm does not test properly 1 Make sure that fresh batteries are installed correctly 2 Be sure the Alarm is clean and dust free 3 Install fresh AA batteries and test the Alarm again AWARNING e DO NOT try fixing the Alarm yourself this will void your warranty If the CO Alarm is still not operating properly and it is still under warranty please see How to Obtain Warranty Service in the Limited Warranty Install a new CO Alarm immediately e The Test Silence button is the only proper way to test the CO Alarm NEVER use vehicle exhaust Exhaust may cause permanent damage and voids your warranty For a list of acceptable replacement batteries see Regular Maintenance REGULAR MAINTENANCE To keep the CO Alarm in good working order e Test it every week using the Test Silence button e Vacuum the CO Alarm cover once a month using the soft brush attach ment Never use water cleaners or solvents since these may damage the unit Test the CO Alarm again after vacuuming e Replace the batteries when the CO Alarm chirps about every minute the low battery warning The low ba
24. ear NOTE End of Life Signal Once the unit reaches the end of its lifecycle the MALFUNCTION SIGNAL will sound once a minute to Date Installed Month Year indicate the need to immediately replace the Alarm First Alert is a registered trademark of the First Alert Trust Printed in Mexico M08 0140 004 P 06 07
25. el write in the phone number of your emer gency responder like 911 and a qualified appliance technician Place one label near the CO Alarm and the other label in the fresh air location you plan to go if the alarm sounds INSTALLING THE AA BATTERIES 1 Flip the battery door down to open 2 Install both AA batteries included inside the battery compartment as indicated Make sure the and ends of each battery are aligned properly A chirp will be issued 3 Close the battery door TO MOUNT ON THE WALL Tools you will need pencil drill with 3 16 or 5mm drill bit flathead screwdriver hammer 1 Choose a location on the wall Do not install the Alarm closer than 4 102 mm from where the wall meets the ceiling 2 Hold the mounting guide template against the wall and make a mark inside each keyhole where you will drill your mounting hole as shown in the diagram below 3 Use a 3 16 5 mm drill bit to drill through the marks you made for the mounting holes 4 Insert the plastic screw anchors into the mounting holes until they are flush with the wall If necessary tap them gently with a hammer 5 Insert the screws into the anchors until the screwhead is 1 8 inch 8 mm away from the wall Slide the CO Alarm onto the screws until you feel it click into place Test the CO Alarm as described in Weekly Testing IF YOUR CO ALARM SOUNDS AWARNING Actuation of your CO Alarm indica
26. he unit if it sounds frequent unwanted alarms See Locations to Avoid for Smoke Alarms for details e When the battery becomes weak the Smoke Alarm unit will chirp about once a minute the low battery warning This low battery warning should last for 30 days but you should replace the battery immediately to continue your protection Choosing a replacement battery Your Smoke Alarm requires one standard 9V battery The following batteries are acceptable as replacements Duracell MN1604 Ultra MX1604 Eveready Energizer 522 You may also use a Lithium battery like the Ultralife U9VL J for longer service life between battery changes These batteries are available at many local retail stores IMPORTANT Actual battery service life depends on the Smoke Alarm and the environment in which it is installed All the batteries specified above are acceptable replacement batteries for this unit Regardless of the manufacturer s suggested battery life you MUST replace the battery immediately once the unit starts chirping the low battery warning IF THIS SMOKE ALARM SOUNDS RESPONDING TO AN ALARM During an alarm you will hear a loud repeating horn pattern 3 beeps pause 3 beeps pause AWARNING e Ifthe unit alarms and you are not testing the unit it is warning you of a potentially dangerous situation that requires your immediate attention NEVER ignore any alarm Ignoring the alarm may result in injury or de
27. ible The placement recommendations are intended to keep these Alarms at a reasonable distance from a fuel burning source and thus reduce unwanted alarms Unwanted alarms can occur if a Smoke Alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible e In air streams near kitchens Air currents can draw cooking smoke into the sensing chamber of a Smoke Alarm near the kitchen e In very damp humid or steamy areas or directly near bathrooms with showers Keep units at least 10 feet 8 meters away from showers saunas dishwashers etc e Where the temperatures are regularly below 40 F 4 C or above 100 F 38 C including unheated buildings outdoor rooms porches or unfinished attics or basements e In very dusty dirty or greasy areas Do not install a Smoke Alarm directly over the stove or range Keep laundry room Smoke Alarms free of dust or lint e Near fresh air vents ceiling fans or in very drafty areas Drafts can blow smoke away from the unit preventing it from reaching the sensing chamber e In insect infested areas Insects can clog openings to the sensing chamber and cause unwanted alarms e Less than 12 inches 305mm away from fluorescent lights Electrical noise can interfere with the sensor e In dead air spaces Dead air spaces may prevent smoke from reaching the Smoke Alarm Avoiding Dead Air Spaces Dead air spaces may prevent s
28. insulation sealed windows and other weatherproofing can trap CO inside SYMPTOMS OF CO POISONING These symptoms are related to CO POISONING and should be discussed with ALL household members Mild Exposure Slight headache nausea vomiting fatigue flu like symptoms Medium Exposure Throbbing headache drowsiness confusion fast heart rate Extreme Exposure Convulsions unconsciousness heart and lung failure Exposure to carbon monoxide can cause brain damage death AWARNING Some individuals are more sensitive to CO than others including people with cardiac or respiratory problems infants unborn babies pregnant mothers or elderly people can be more quickly and severely affected by CO Members of sensitive populations should consult their doctors for advice on taking additional precautions FINDING THE SOURCE OF CO AFTER AN ALARM Carbon monoxide is an odorless invisible gas which often makes it difficult to locate the source of CO after an alarm These are a few of the factors that can make it difficult to locate sources of CO e House well ventilated before the investigator arrives e Problem caused by backdrafting e Transient CO problem caused by special circumstances Because CO may dissipate by the time an investigator arrives it may be difficult to locate the source of CO BRK Brands Inc shall not be obligated to pay for any carbon monoxide investigation or service call HOW CAN I
29. itional areas include the base ment bedrooms dining room furnace room utility room and hallways not protected by the required Smoke Alarms The installation of Smoke Alarms in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation California State Fire Marshal CSFM Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A Smoke Alarm installed in each separate sleeping area in the vicinity but outside bedrooms and Heat or Smoke Alarms in the living rooms dining rooms bedrooms kitchens hallways finished attics furnace rooms closets utility and storage rooms basements and attached garages LOCATIONS TO AVOID FOR SMOKE ALARMS For best performance it is recommended you AVOID installing Smoke Alarms in these areas e Where combustion particles are produced Combustion particles form when something burns Areas to avoid include poorly ventilated kitchens garages and furnace rooms Keep units at least 20 feet 6 meters from the sources of combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6 meter distance is not possible in modular mobile or smaller homes for example it is recommended the Smoke Alarm be placed as far from these fuel burning sources as poss
30. ividuals If children or others do not readily waken to the sound of the CO alarm or if there are infants or family members with mobility limitations make sure that someone is assigned to assist them in the event of an emergency CO Alarms will not work without power This alarm requires two standard AA batteries to operate CO Alarms for Solar or Wind Energy users and battery backup power systems AC powered CO Alarms should only be operated with true or pure sine wave inverters Operating this Alarm with most battery powered UPS uninterruptible power supply products or square wave or quasi sine wave inverters will damage the Alarm If you are not sure about your inverter or UPS type please consult with the manufacturer to verify This CO Alarm will not sense carbon monoxide that does not reach the sensor This CO Alarm will only sense CO at the sensor CO may be present in other areas Doors or other obstructions may affect the rate at which CO reaches the CO Alarm For this reason if bedroom doors are usually closed at night we recommend you install a CO Alarm in each bedroom and in the hallway between them CO Alarms may not sense CO on another level of the home For example a CO Alarm on the second level near the bedrooms may not sense CO in the basement For this reason one CO Alarm may not give adequate warning Complete coverage is recommended Place CO Alarms on each level of the home CO Alarms may not be heard The
31. le nose pliers detach one locking pin from mounting bracket Insert the locking pin into the lock located on the pivoting hinge of the battery door When you attach the Smoke Alarm to the mounting bracket the locking pin s head will fit into a notch on the bracket TO UNLOCK THE BATTERY COMPARTMENT Remove the Smoke Alarm from the mounting bracket If the unit is locked to the bracket see the section To Unlock the Mounting Bracket Insert a flathead screwdriver under the head of the locking pin and gently pry it out of the battery compartment lock If you plan to relock the battery fi compartment save the locking pin T 3 To relock the battery compartment close the battery door and reinsert locking pin in lock 4 Reattach the Smoke Alarm to the mounting bracket IMPORTANT When replacing the battery always test the Smoke Alarm before relocking the battery compartment TO UNLOCK THE MOUNTING BRACKET Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket Pry the Smoke Alarm away from the bracket by turning both the screwdriver and the Smoke Alarm counterclockwise left at the same time WEEKLY TESTING AWARNING NEVER use an open flame of any kind to test this unit You might accidentally damage or set fire to the unit or to your home The built in test switch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL It is
32. ly CO Alarms are not foolproof Like all other electronic devices CO Alarms have limitations They can only detect CO that reaches their sensors They may not give early warning to rising CO levels if the CO is coming from a remote part of the home away from the CO Alarm TROUBLESHOOTING GUIDE PROBLEM YOU SHOULD The light continues to flash RED and the horn Low battery warning Install 2 new AA batteries chirps once every minute The light flashes RED and the horn sounds 3 quick MALFUNCTION SIGNAL CO Alarm needs to be CO Alarms under warranty should be returned to chirps every minute replaced manufacturer for replacement See Limited Warranty for details CO Alarm goes back into alarm 4 minutes after you CO levels indicate a potentially dangerous situation IF YOU ARE FEELING SYMPTOMS OF CO press the Test Silence button POISONING EVACUATE your home and call 911 or the Fire Department If not press the Test Silence button again and keep ventilating your home CO Alarm sounds frequently even though no high The CO Alarm may be improperly located Refer to Relocate your alarm If frequent alarms continue levels of CO are revealed in an investigation Where to Install CO Alarms have home rechecked for potential CO problems You may be experiencing an intermittent CO problem For a list of acceptable replacement batteries see Page 4 Regular Maintenance If you have any questions that
33. means CO levels are still potentially starts sounding loudly 4 beeps dangerous pause 4 beeps pause If the CO Alarm This means Remains silent after you pressed the Test Silence button CO levels are dropping SILENCING THE LOW BATTERY WARNING This silence feature can temporarily quiet the low battery warning chirp for up to 8 hours You can silence the low battery warning chirp by pressing the Test Silence button The LED will flash twice acknowledging that the low battery silence feature has been activated After 8 hours the low battery chirp will resume Replace the batteries as soon as possible this unit will not operate without battery power To deactivate this feature Press the Test Silence button again The unit will go into Test Mode and the low battery warning will resume LED flashes and unit sounds chirp once a minute If you cannot silence the low battery warning replace the batteries immediately Mounting Guide Template 2 5 inches 64 mm TESTING amp MAINTENANCE WEEKLY TESTING AWARNING e Test the CO Alarm once a week If the CO Alarm ever fails to test correctly have it replaced immediately If the CO Alarm is not working properly it cannot alert you to a problem e DO NOT stand close to the Alarm when the horn is sounding Exposure at close range may be harmful to your hearing When testing step away when horn starts sounding Push and hold the Test Silenc
34. moke from reaching the Smoke Alarm To avoid dead air spaces follow the installation recommendations below On ceilings install Smoke Alarms as close to the center of the ceiling as possible If this is not possible install the Smoke Alarm at least 4 inches 102 mm from the wall or corner For wall mounting if allowed by building codes the top edge of Smoke Alarms should be placed between 4 and 12 inches 102 and 305 mm from the wall ceiling line below typical dead air spaces On a peaked gabled or cathedral ceiling install the first Smoke Alarm within 3 feet 0 9 meters of the peak of the ceiling measured horizontally Additional Smoke Alarms may be required depending on the length angle etc of the ceiling s slope Refer to NFPA 72 for details on require ments for sloped or peaked ceilings ABOUT SMOKE ALARMS Battery DC operated Smoke Alarms Provide protection even when electricity fails provided the batteries are fresh and correctly installed Units are easy to install and do not require professional installation AC powered Smoke Alarms Can be interconnected so if one unit sens es smoke all units alarm They do not operate if electricity fails AC with battery DC back up will operate if electricity fails provided the batteries are fresh and correctly installed AC and AC DC units must be installed by a qualified electrician Smoke Alarms for Solar or Wind Energy users and battery backup power system
35. nd at least one Smoke Alarm on every level of your home in every bedroom and in every bedroom hallway or separate sleeping area See Recommended Locations For Smoke Alarms and Locations To Avoid For Smoke Alarms for details Know What Smoke Alarms Can and Can t Do A Smoke Alarm can help alert you to fire giving you precious time to escape It can only sound an alarm once smoke reaches the sensor See Limitations of Smoke Alarms for details Check Your Local Building Codes This Smoke Alarm is designed to be used in a typical single family home It alone will not meet requirements for boarding houses apartment buildings hotels or motels See Special Compliance Considerations for details AWARNING e This unit will not alert hearing impaired residents It is recom mended that you install special units which use devices like flashing strobe lights to alert the hearing impaired Do not connect this unit to any other alarm or auxiliary device It is a single station unit that cannot be linked to other devices Connecting anything else to this unit may prevent it from working properly Unit will not operate without battery power The Smoke Alarm cannot work until you install the battery in the correct position Match to and to This Smoke Alarm has a battery drawer which resists closing unless a battery is installed This warns you the unit will not operate without a battery
36. nd unit malfunction warning UNDERSTANDING YOUR CO ALARM WELCOME CHIRP Horn chirps and light blinks once when batteries are first connected ALARM RECEIVING BATTERY POWER Light flashes every minute Horn is silent LOW BATTERY WARNING The light continues to flash RED and the horn also chirps once every minute This warning should last for up to 30 days but you should replace the batteries as soon as possible DURING TESTING Light flashes Red in sync with the horn pattern 4 beeps pause 4 beeps simulating a CO Alarm condition CO ALARM Sensor has detected enough CO to trigger an alarm Light flashes rapidly and horn sounds loudly repeating 4 beeps pause See If Your CO Alarm Sounds for details During an alarm move everyone to a source of fresh air DO NOT move the CO Alarm CO ALARM REQUIRES SERVICE MALFUNCTION SIGNAL The light flashes RED and the horn sounds 3 quick chirps every minute CO Alarm needs to be replaced INSTALLATION WHERE TO INSTALL CO ALARMS The National Fire Protection Association NFPA recommends that a CO Alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms For added protection install additional CO Alarms in each separate bedroom and on every level of your home If your bedroom hallway is longer than 40 feet 12 meters install a CO Alarm at BOTH ends of the hallway gt BEDROO
37. ndos provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances regulations 3 Institutions Hospitals day care facilities long term health care facilities This Smoke Alarm is suitable for use in individual patient sleeping resident rooms provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances regulations 4 Hotels and Motels Also boarding houses and dormitories This Smoke Alarm is suitable for use inside individual sleeping resident rooms provided a primary fire detection system already exists to meet fire detection requirements in common areas like lobbies hallways or porches Using this Smoke Alarm in common areas may not provide sufficient warning to all residents or meet local fire protection ordinances regulations LIMITATIONS OF SMOKE ALARMS Smoke Alarms have played a key role in reducing deaths resulting from home fires worldwide However like any warning device Smoke Alarms can only work if they are properly located installed and maintained and if smoke reaches them They are not fool
38. ngers e Check the house or garage on the other side of shared wall e Keep windows and doors open slightly If you suspect that CO is escaping into your home open a window or a door Opening windows and doors can significantly decrease CO levels In addition familiarize yourself with all enclosed materials Read this manual in its entirety and make sure you understand what to do if your CO Alarm sounds Fuel burning appliances like portable heater gas or wood burning fireplace gas kitchen range or cooktop gas clothes dryer Damaged or insufficient venting corroded or disconnected water heater vent pipe leaking chimney pipe or flue or cracked heat exchanger blocked or clogged chimney opening Improper use of appliance device operating a barbecue grill or vehicle in an enclosed area like a garage or screened porch Transient CO Problems transient or on again off again CO problems can be caused by outdoor conditions and other special circumstances POTENTIAL SOURCES OF CO IN THE HOME The following conditions can result in transient CO situations 1 Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as e Wind direction and or velocity including high gusty winds Heavy air in the vent pipes cold humid air with extended periods between cycles e Negative pressure differential resulting from the use of exhaust fans e Several appliances running a
39. proof Smoke alarms may not waken all individuals Practice the escape plan at least twice a year making sure that everyone is involved from kids to grandparents Allow children to master fire escape planning and practice before holding a fire drill at night when they are sleeping If children or others do not readily waken to the sound of the smoke alarm or if there are infants or family members with mobility limitations make sure that someone is assigned to assist them in fire drill and in the event of an emergency It is recommended that you hold a fire drill while family members are sleeping in order to determine their response to the sound of the smoke alarm while sleeping and to determine whether they may need assistance in the event of an emergency Smoke Alarms cannot work without power Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC units cannot work if the AC power is cut off for any reason open fuse or circuit breaker failure along a power line or at a power station electrical fire that burns the electrical wires etc If you are concerned about the limitations of battery or AC power install both types of units Smoke Alarms cannot detect fires if the smoke does not reach them Smoke from fires in chimneys or walls on roofs or on the other side of closed doors may not reach the sensing chambe
40. r and set off the alarm That is why one unit should be installed inside each bedroom or sleeping area especially if bedroom or sleeping area doors are closed at night and in the hallway between them Smoke Alarms may not detect fire on another floor or area of the home For example a stand alone unit on the second floor may not detect smoke from a basement fire until the fire spreads This may not give you enough time to escape safely That is why recommended mini mum protection is at least one unit in every sleeping area and every bedroom on every level of your home Even with a unit on every floor stand alone units may not provide as much protection as interconnected units especially if the fire starts in a remote area Some safety experts recommend installing interconnected AC powered units with battery back up see About Smoke Alarms or professional fire detection sys tems so if one unit senses smoke all units alarm Interconnected units may provide earlier warning than stand alone units since all units alarm when one detects smoke Smoke Alarms may not be heard Though the alarm horn in this unit meets or exceeds current standards it may not be heard if 1 the unit is located outside a closed or partially closed door 2 residents recently consumed alcohol or drugs 3 the alarm is drowned out by noise from stereo TV traffic air conditioner or other appliances 4 residents are hearing impaired or sound sleepers Special
41. rce of high humidity e In areas where temperature is colder than 40 F 4 C or hotter than 100 F 38 C These areas include unconditioned crawl spaces unfinished attics uninsulated or poorly insulated ceilings porches and garages e In turbulent air like near ceiling fans heat vents air conditioners fresh air returns or open windows Blowing air may prevent CO from reaching the sensors e Outside the Mobile Home e In direct sunlight AWARNING e This CO Alarm is designed for use inside a single family home or apartment It is not meant to be used in common lobbies hallways or basements of multi family buildings unless working CO Alarms are also installed in each family living unit CO Alarms in common areas may not be heard from inside individual family living units e This CO Alarm alone is not a suitable substitute for complete detection systems in places which house many people like hotels or dormitories unless a CO Alarm is also placed in each unit e DO NOT use this CO Alarm in warehouses industrial or commercial buildings special purpose non residential buildings or airplanes This CO Alarm is specifically designed for residential use and may not provide adequate protection in non residential applications HOW TO INSTALL YOUR CO ALARM Read Where To Install Your CO Alarm before starting Before you start installation find the pair of self adhesive labels included with this CO Alarm On each lab
42. replaced immediately If the CO Alarm is not working properly it cannot alert you to a problem e This product is intended for use in ordinary indoor locations of family living units It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration OSHA commer cial or industrial standards Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 ppm For additional information on carbon monoxide and your medical condition contact your physician HOW YOUR CO ALARM WORKS GENERAL INFORMATION AWARNING e This CO Alarm does not operate without working batteries Removing the batteries or failure to replace them at the end of their service life removes your protection ACO Alarm measures the CO levels in the air It will alarm if CO levels rise quickly if the heat exchanger on your furnace breaks for example or if CO is consistently present a slow CO leak on a fuel burning appliance This Carbon Monoxide Alarm features a permanently installed sensor and an 85 dB alarm horn It also has a silence feature to temporarily quiet the alarm horn THE PARTS OF YOUR CO ALARM 1 Open door here 4 Battery Compartment 2 Test Silence Button 5 Behind Cover Alarm Horn 85dB audible alarm for test alarm 3 POWER ALARM Light RED ight a
43. s AC powered Smoke Alarms should only be operated with true or pure sine wave inverters Operating this Smoke Alarm with most battery powered UPS uninterruptible power supply products or square wave or quasi sine wave inverters will damage the Alarm If you are not sure about your inverter or UPS type please consult with the manufacturer to verify Smoke Alarms for the hearing impaired Special purpose Smoke Alarms should be installed for the hearing impaired They include a visual alarm and an audible alarm horn and meet the requirements of the Americans With Disabilities Act Can be interconnected so if one unit senses smoke all units alarm Smoke alarms are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose All these Smoke Alarms are designed to provide early warning of fires if located installed and cared for as described in the user s manual and if smoke reaches them If you are unsure which type of Smoke Alarm to install refer to Chapter 2 of the National Fire Protection Association NFPA Standard 72 National Fire Alarm Code and NFPA 101 Life Safety Code National Fire Protection Association One Batterymarch Park Quincy MA 02269 9101 Local building codes may also require specific units in new construction or in different areas of the home SPECIAL COMPLIANCE CONSIDERATIONS AWARNING This Smoke Alarm alone is not a suitable substitute for complete
44. s an immediate life threat Since you cannot see or smell CO never assume it s not present e An exposure to 100 ppm of CO for 20 minutes may not affect average healthy adults but after 4 hours the same level may cause headaches e An exposure to 400 ppm of CO may cause headaches in average healthy adults after 35 minutes but can cause death after 2 hours IMPORTANT This CO Alarm measures exposure to CO over time It alarms if CO levels are extremely high in a short period of time or if CO levels reach a certain minimum over a long period of time The CO Alarm generally sounds an alarm before the onset of symptoms in average healthy adults Why is this important Because you need to be warned of a potential CO problem while you can still react in time In many reported cases of CO exposure victims may be aware that they are not feeling well but become disoriented and can no longer react well enough to exit the building or get help Also young children and pets may be the first affected The average healthy adult might not feel any symptoms when the CO Alarm sounds However people with cardiac or respiratory problems infants unborn babies pregnant mothers or elderly people can be more quickly and severely affected by CO If you experience even mild symptoms of CO poisoning consult your doctor immediately Standards Underwriters Laboratories Inc Single and Multiple Station carbon monoxide alarms UL2034 According to Under
45. sembly repair or alteration by anyone other than BRK or an author ized service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes or any batteries that are included with this unit BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty Except to the extent prohibited by applicable law any implied warranty of merchantabil ity or fitness for a particular purpose is limited in duration to the duration of the above warranty Some states provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limita tions or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province How to Obtain Warranty Service Service If service is required do not return the product to your retailer In order to obtain warranty service contact the Consumer Affairs Division at 1 800 323 9005 7 30 AM 5 00 PM Central Standard Time Monday through Friday To assist us in serving you please have the model number and date of purchase available when calling For Warranty Service return to BRK Brands Inc 25 Spur Drive El Paso TX 79906 Battery BRK Brands Inc make no warranty express or implied written or oral including
46. t the same time competing for limited fresh air e Vent pipe connections vibrating loose from clothes dryers furnaces or water heaters e Obstructions in or unconventional vent pipe designs which can amplify the above situations 2 Extended operation of unvented fuel burning devices range oven fireplace 3 Temperature inversions which can trap exhaust close to the ground 4 Car idling in an open or closed attached garage or near a home These conditions are dangerous because they can trap exhaust in your home Since these conditions can come and go they are also hard to recreate during a CO investigation REGULATORY INFORMATION FOR CO ALARMS WHAT LEVELS OF CO CAUSE AN ALARM Underwriters Laboratories Inc Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below They are measured in parts per million ppm of CO over time in minutes UL2034 Required Alarm Points e If the alarm is exposed to 400 ppm of CO IT MUST ALARM BETWEEN 4 and 15 MINUTES e If the alarm is exposed to 150 ppm of CO IT MUST ALARM BETWEEN 10 and 50 MINUTES e Ifthe alarm is exposed to 70 ppm of CO IT MUST ALARM BETWEEN 60 and 240 MINUTES Approximately 10 COHb exposure at levels of 10 to 95 Relative Humidity RH The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days IMPORTANT CO Alarms are designed to alarm before there i
47. tes the presence of carbon monoxide CO which can kill you In other words when your CO Alarm sounds you must not ignore it IF THE ALARM SIGNAL SOUNDS 1 Operate the Test Silence button 2 Call your emergency services fire department or 911 Write down the number of your local emergency service here 3 Immediately move to fresh air outdoors or by an open door or window Do a head count to check that all persons are accounted for Do not re enter the premises or move away from the open door or window until the emergency services responder has arrived the premises have been aired out and your CO Alarm remains in its normal condition 4 After following steps 1 3 if your CO Alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance technician to inves tigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are iden tified during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturers instructions or contact the manufacturers directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence Write down the number of a qualified appliance technician here ALARM MOVE TO FRESH AIR If you hear the al
48. ttery warning should last for 30 days but you should replace the battery immediately to continue your protection Choosing a replacement battery This CO Alarm requires two standard AA batteries The following batteries are acceptable as replacements Energizer E91 These replacement batteries are commonly available at local retail stores IMPORTANT Use only the replacement batteries listed The unit may not operate properly with other batteries Never use rechargeable batteries since they may not provide a constant charge ACAUTION DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm DO NOT paint over the CO Alarm Doing so may cause permanent damage IMPORTANT Household cleaners aerosol chemicals and other contaminants can affect the sensor When using any of these materials near the CO Alarm make sure the room is well ventilated WHAT YOU NEED TO KNOW ABOUT CO WHAT IS CO CO is an invisible odorless tasteless gas produced when fossil fuels do not burn completely or are exposed to heat usually fire Electrical appliances typically do not produce CO These fuels include Wood coal charcoal oil natural gas gasoline kerosene and propane Common appliances are often sources of CO If they are not properly main tained are improperly ventilated or malfunction CO levels can rise quickly CO is a real danger now that homes are more energy efficient Air tight homes with added
49. writers Laboratories Inc UL2034 Section 1 1 2 Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as but not limited to exhaust from internal combustion engines abnormal operation of fuel fired appliances and fireplaces CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure This CO Alarm monitors the air at the Alarm and is designed to alarm before CO levels become life threatening This allows you precious time to leave the house and correct the problem This is only possible if Alarms are located installed and maintained as described in this manual Gas Detection at Typical Temperature and Humidity Ranges The CO Alarm is not formulated to detect CO levels below 30 ppm typically UL tested for false alarm resistance to Methane 500 ppm Butane 800 ppm Heptane 500 ppm Ethyl Acetate 200 ppm Isopropyl Alcohol 200 ppm and Carbon Dioxide 5000 ppm Values measure gas and vapor concentrations in parts per million Audible Alarm 85 dB minimum at 10 feet 3 meters GENERAL LIMITATIONS OF CO ALARMS This CO Alarm is intended for residential use It is not intended for use in industrial applications where Occupational Safety and Health Administration OSHA requirements for carbon monoxide detectors must be met CO alarms may not waken all ind
50. y others you must leave this manual or a copy of it with the end user TABLE OF CONTENTS introduction sinan ste teaveaS oen eave ce een de texas 1 2 Basic Safety Information scoe 0 062 ccna ee eee eed 1 How Your CO Alarm Works okenne teneis nanas aaa da iie 1 Understanding Your CO Alarm 11 2 eee eee 2 INStallatiOn ccccscca ee ern eeLeUERnee eee OERETEEE RETR eR ee 2 3 Where to Install CO Alarms 0 00 ce cece eee eee eee 2 Where CO Alarms Should NOT Be Installed 5 2 How to Install Your CO Alarm 0 000 e cece eee 3 If Your CO Alarm Sounds 0 00 c cece eee el 3 If the Alarm Signal Sounds c060cccoeneyweeeewe em wagon oreda 3 Using the Silence Feature 2 2 6ceces anne eee ee oom eS 3 Testing and Maintenance 0 0 0 eee eee eee eee 4 Weekly Testi ii scacssnceahs stratenou t Za Wik Bice a o bie lose ate caoned 4 Regular MaintenanGe ia ies eee eevee saosin an eae aaa de eyle evened eee 4 What You Need To Know About CO 2 cece eel 4 5 WRAL IS CO Pics bow cade Cae aed hee UREA E ORES eee awed 4 Symptoms of CO POISONING 2c ccisiiisicis eee a note ape doe tie ae at 4 Finding the Source of CO After an Alarm 0 0 000 4 How Can Protect My Family 0 000 0000 cee eee 4 Potential Sources of CO inthe Home 2020 e eee eres 5 Regulatory Information for CO Alarms 0000ece cece eee en eeee 5 General Limitations Of CO Alarms