Home
UVCT-AR - User manual
Contents
1. Note Open UV lamp operation can be checked with the visible light lamp switched off switch 1 is OFF Use the indicator in the center of recirculator cover to check operation of UV lamp inside the recirculator If indicator is lights from inside while switch 2 is ON then the UV lamp is functioning Use the timer and keys Fig 1 4 to set the time UV LIGHT TIME CONTROLLER of direct UV light exposition of the working place to increase exposition time the increment is 1 min to decrease exposition time the increment is 1 min Pressing down and holding the button for more than 2 sec will increase the increment Recommended time of exposition is 15 min Press the Start key Fig 1 3 the UV lamp will be turned on automatically and the timer will start counting up the exposition time Timer indicator shows actual time till 1 hour in minutes and seconds mmiss after 1 hour in hours and minutes hh mm After reaching the set time the timer will automatically turn off the open UV lamp 1 VISIBLE LIGHT 2 UV RECIRCULATOR UV LIGHT Start Stop Reset Fig 1 Control Panel 4 2 4 4 2 5 4 3 4 3 1 4 3 2 4 3 3 4 3 4 4 4 10 The open UV lamp can be switched off by pressing the Stop Reset key Fig 1 5 The set time of exposition will be saved in the memory The set time won t be saved after the complete switching off the unit If the set time of open UV light exposition is
2. 0 00 pressing the Start key will make the unit operate continuously during 24 hrs or until the Stop Reset key is pressed UV cleaner cabinet is ready for use Work in the Box Note Opening the front protective screen will automatically switch off the open UV lamp but the timer will continue counting up the exposition time Turn ON switch 1 Fig 1 1 for lighting of the working place this turns ON the Luminescent Visible light lamp Open the front protective screen up for work in the cabinet After the task is done close the front protective screen After finishing the operation turn OFF switch 2 and switch 1 Disconnect the power cord from electric circuit 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C Open UV lamp ss a ias a ja Via I aa asi TUV 25 W G13 UV C Radiation ype as a a i k a as UV 254 nm ozone free LIN TANI life ius S 9000 hrs WN FOCIRCUIAION is asa iii Sia E TUV 25 W G13 UV C Digital time setting of direct UV exposure L 1 min 24 h VISIDIGTIGIIE AMD T 15 W 830 G13 Plexiglass TYPO ececcecseeeeceseseceeeeeeeeeeeseesenseesaes Polymethylmethacrylate Optical tranSMISSION nirre sana eae ii Asi aa i S A 92 LIN PrOtECHON ciune 8 ites anda ei tated aaah
3. 99 9 Protection na YDE 1 ania Ta iai a a ate as a alee a 4 MIL CLEAR Thickness of sides Panels Lasa i e ai i a ed eee 4 mm Thickness of upper front Panel ccccecceeeeeeeeeeeeeeeeeceeeeeeeeeeeaees 8mm Thickness of front protective screen aaa kaka aaa aaa akanai 8mm WOKING PIACE 115 asis asas ia ini ai a La i 650x475 mm Overall size sietini saaa saaa e aaa sa o saaa aaa a 690x535x555 mm Operating voltage power consumption 100 240 V 50 60 Hz 67 W AUS 0 EL Ansa ausa ikainiai IS As Les a i i ener ert 23 kg Optional nae p i Description accessories 7 4 moving table with a drawer and wheel locks dimensions 800x600x745 mm Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Accurate within 10 6 1 6 2 6 3 6 4 6 5 12 Maintenance If the unit requires maintenance disconnect the unit from the electric circuit and contact Biosan or your local Biosan representative All maintenance and repair operations must be performed only by qualified and specially trained personnel Fuse replacement Disconnect the unit from the electric circuit and remove the power plug from the rear of the unit Pull out the fuse holder by applying leverage in recess Fig 2 A Remove the i fuse from the holder Check and replace with Fig 2 Fuse replacement the correct fuse if necessar
4. aaa aaa 1 pce spare dust fiLES 0 4 pcs spare fuse inside the fuse holder c cece eeeseeeeeeeeeeeeeeeeeeeneesaeenes 1 pce POWE aso pe nee nee ner Cen anne ee ye ee eee er ee eee 1 pce Operating manual Certificate aaa aaa aaa Aaaa aa senses aaa aaa 1 copy Optional accessories T 4 moving table for UV cleaner box aaa aaa aaa on reguest T 4 Set up if the T 4 table is used unpack it carefully and assemble according to the enclosed assembling scheme place the unit upon stable surface Ensure that the unit is placed on a solid level surface not less than 720x550 mm which is able to support its weight and the weight of equipment and materials inside for instance on the T 4 table plug the power cable into the socket on the rear and position the unit so that there is easy access to the power switches and the power plug 4 1 4 2 4 2 1 4 2 2 4 2 3 Operation Connect the power plug to a grounded power socket UV exposition of the working place Caution Do not work in the cabinet or open the front protective screen while the open UV lamp is switched ON Otherwise it can expose the operator to a dangerous level of UV emission Turn ON switch 2 Fig 1 2 This automatically turns on the UV recirculator with the hidden UV lamp and activates the timer of open UV lamp The UV recirculator will operate all the time until switch 2 is turned OFF
5. BIOSAFETY EOUIPMENT Dioan UV cabinet Medical Biological Research amp Technologies UVC T AR DNA RNA UV cleaner box for versions V 3AD Operating Manual Certificate Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims HL Lai eS Declaration of Conformity 1 Safety Precautions The following symbols mean A 2 Caution Do not work in the cabinet or open the front protective screen while the open UV lamp is switched ON Otherwise it can expose the operator to a dangerous level of UV emission Caution Make sure you have fully read and understood the present Manual before using the eguipment Please pay special attention to sections marked by this symbol A Caution Exposure to UV light is harmful and can cause damage to unprotected eyes and skin The UV cleaner box contains a powerful source of UV radiation therefore before operating the unit ensure all personnel working with the UV cleaner box are properly protected The operator should wear a closed front lab coat fully buttoned UV certified safety glasses and gloves which should overlap the lab coat or surgical gown cuffs GENERAL SAFETY e Use only as specified in the Operating Manual provided e The unit should not be used if dropped or damaged e After transportation or storage keep the unit under room temperature for 2 3 hrs before connecting it to the
6. d ty Z6 02 2014 2 0 02 20 14 Date Date 15 Biosan SIA Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 6742 6137 Fax 371 6742 8101 http www biosan lv Version 3 02 July 2014
7. electric circuit e Use only cleaning and decontamination methods recommended by the manufacturer e Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to electric circuit with voltage corresponding to that on the serial number label Ensure that the switches and plug are easily accessible during use Do not plug the unit into an ungrounded power socket and do not use an ungrounded extension lead Disconnect the unit from the electric circuit before moving If liquid penetrates into the unit disconnect it from the electric circuit and have it checked by a repair and maintenance technician Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in the Specifications section DURING OPERATION Do not operate the unit in environments with aggressive or explosive chemical mixtures Please contact manufacturer for possible operation of the unit in specific atmospheres Do not operate the unit without dust filters installed Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside laboratory rooms Do not work in the box while the open UV lamp is switched ON BIOLOGICAL SAFETY It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment 2 General Information Bench top model of DNA RNA UV cleaner box UVC T AR is special
8. ents The warranted service life of unit from date of delivery to the Customer is 24 months exclude lamps and dust filters Contact your local distributor to check availability of extended warranty If any manufacturing defects are discovered by the Customer an unsatisfac tory equipment claim shall be compiled certified and sent to the local dis tributor address Please visit www biosan lv Technical support section to ob tain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and retain for your records UVC T AR DNA RNA UV cleaner box C T Declaration of Conformity Declaration of Conformity Eguipment name UVC T AR Type of eguipment DNA RNA UV cleaner box Directive EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC 8 2012 19 EU SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Applied Standards EN 61326 1 Electrical eguipment for measurement control and laboratory use EMC reguirements General reguirements EN 61010 1 Safety reguirements for electrical eguipment for measurement control and laboratory use General reguirements We declare that this product conforms to the reguirements of the above Directive s ee a oi 44 A Signature Signature Svetlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D os 7 sr ON fa ah
9. he cabinet Cabinet UV lamps do not produce ozone DNA RNA UV cleaner box with the built in recirculator is a patented solution Patent number LV13115 of 20 05 2004 Dr biol V Bankovsky Microbiological studies at the R amp D Department of Biosan led by Dr biol V Bankovsky demonstrated a high level of biosafety and efficacy of UV cleaner box UVC T AR maximal level of contamination is 1 3 cfu per 100 liters of air UV cleaner box is designed to protect the product but not the operator therefore it is not recommended to use the UV cleaner box for working with pathogenic microorganisms http biosan lv efficiency eng Advantages No HEPA filters UV recirculator Ozone free high density UV decontamination Open UV lamp is switched off automatically in case of opening the protective front screen Long life UV lamps 9000 h Low noise level Low energy consumption Compact bench top model for personal labs Optional table with drawer T 4 on request 2 1 3 3 Getting started Unpacking Remove packing materials carefully and retain them for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage Caution Due to the unit s weight its unpacking and installing is to be carried out by two persons Complete set Package contents Standard set UVC T AR DNA RNA UV cleaner box aaa kaka aaa
10. ly designed for laboratories of molecular biology DNA analysis and genetic engineering The front panel of UV cleaner box with a folding protective screen side and rear walls are made of durable plexiglas The working surface is of stainless steel The framework and the top are of steel with chemical resistant powder coating At the rear wall there is an inlet for power cords At the top of the working area of UV cleaner box there are Fluorescent lamp 15 W for working area illumination 2 Open UV lamp 25 W for working area disinfection UV Recirculator 25 W for amplicon inactivation inside the UV cleaner box A digital timer controls duration of working surface irradiation with UV light in the range from O to 24 hours In case of opening the protective front screen during UV irradiation open UV lamp is switched off automatically UV recirculator consists of a UV lamp a fan and dust filters organized in a plastic case Operator working in a UV cleaner box UVC T AR with a switched on UV recirculator is not exposed to UV radiation It allows continuous treatment of the airflow with UV light without interrupting working process Air circulation at a short distance from the UV lamp combined with reflective surfaces in the air duct results in increased density of UV rays leading to higher efficiency of disinfection UV recirculator generates 100 volumes of PCR cabinet per one hour of airflow exchange ensuring maximally aseptic conditions inside t
11. mmonia containing cleaners for plexiglass Do not use abrasive pads or cleansers 6 6 For decontamination it is recommended to use a special DNA RNA removing solution e g DNA Exitus PlusTM RNase Exitus PlusTM After washing the inside parts of the box it is necessary to rub them dry The table below shows the interreaction of plexiglass with ethyl alcohol and other solutions Interreaction with plexiglass DNA Exitus PlusTM RNase Exitus PlusTM No reaction Ethyl alcohol 10 15 Crazing is a normal process for plexiglass panels exposed to open UV light Crazing will occur over a period of time Reduce crazing by keeping exposure to open UV to a minimum Crazing may occur within the warranty period and is regarded as normal wear and not covered by the warranty Plexiglass panels can be replaced Refer to Replacement Parts for ordering information 6 7 Dust filter replacement The dust filters on either end of the UV recirculator with the hidden UV lamp should be checked monthly and cleaned or replaced when they become clogged To check replace or clean the filters simply unclip the covers if it is necessary fit a new or rinse in water dry and set up existing filters Clip covers back in place dele 1 2 7 3 1 4 14 Warranty and Claims The Manufacturer guarantees the compliance of unit with the requirements of Specifications provided the Customer follows the operation storage and transportation requirem
12. y 3 15 A for 100 V 50 60 Hz UV lamp replacement Average life time of UV lamps supplied is 9000 hrs Replacement is necessary after lamp stops functioning or at the end of manufacturer speci fied life time It is allowed to perform lamps replacement only to the persons who have completed special training Open UV lamp operation can be checked with the visible light off switch 1 is OFF Use the indicator in the center of recirculator cover to check operation of UV lamp inside the recirculator If indicator is lights from inside while switch 2 is ON then the UV lamp is functioning Care and Cleaning The front panel front protective panel and side panels are made of plexi glass and are prone to scratches and optical transmission capacity decrease if improperly cleaned Care during cleaning and use of the equipment is rec ommended to reduce wear of the coating on the plexiglass Cleaning the unit unplug the unit from electric circuit before cleaning use mild soap and water with a soft cloth or sponge for cleaning the unit exterior use a mild detergent for all the interior surfaces wipe excess water from inside and outside the unit with an absorbent soft cloth or sponge AN Caution Do not allow moisture to enter the control box Caution Clean the front protective screen and side panels with a mild AN detergent never use organic based compounds pure alcohol alcohol containing cleaners more than 15 or A
Download Pdf Manuals
Related Search
Related Contents
Jwin JX-MP234 User's Manual STD-403 STEP Motor driver User manual Validação da Candidatura a Mobilidade Interna Ferm Soldering Kit FSK-100 Direct Matin Bordeaux7 iiView 706NB Laptop User Manual Mitel M2006 User's Manual Serie CS3000 - Motorola Solutions Sony UNIONEP550C2 surveillance camera Copyright © All rights reserved.