1. cnet 30 PRISM MEDICAL Owner s Manual Use and Care 45 Progress Parkway Maryland Heights 63043 USA T 1 866 891 6502 314 692 9135 Trouble Shooting F 314 692 7858 Warranty Information CAUTION DO NOT ATTEMPT USE THIS EQUIPMENT WITHOUT FIRST UNDERSTANDING THE CONTENTS OF THIS MANUAL Introduction Before using this equipment and to ensure the safe operation of your FGA 330 portable floor lift careful ly read this entire manual especially the section on Cautions The FGA 330 is designed to be used in conjunction with Prism Medical accessories and slings Please refer to any user guides supplied with these components and refer to them while reviewing this manual Should any questions arise from reviewing this manual contact your local authorized Prism Medical Repre sentative Failure to comply with warnings in this manual may result in injury to either the operator or the in dividual being lifted transferred Damage to the floor lift and or related components may also occur Be sure that the contents of this manual are completely understood prior to using this floor lift Store this manual with the documents included with the floor lift and sling s Contents of this manual are subject to change without prior written notice Overview of FGA 330 Portable Floor Lift The FGA 330 portable floor lift is a lifting aid used by health care pro
2. 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 2 Components of the FGA 330 Portable Floor Lift Boom Up amp Down Actuator QRS Locking Carry Bar Front Caster Rear Caster w Brake Hand Control Mast Push Handle Batter Control Box Foot Pedal for Leg Spreading 280420 FGA 330 Owner s Manual QRS Locking Carry Bar Rev 11 18 12 Page 3 Component List The following components are included with your new FGA 330 portable floor lift system e FGA 330 portable floor lift e Hand Control e Floor Lift Integrated Charger e Charger Cord e Owner s Manual e Multi Function Wrenches e 4mm Hex Allen Key Short Arm e 3mm Hex Allen Key Short Arm SLINGS If a sling has been supplied with floor lift then refer to the instructions included with the sling ACCESSORIES If additional accessories such as a weigh scale have been supplied with the floor lift then refer to the instructions included with those items IMPORTANT Before initial use the floor lift unit must be charged for 4 to 5 hours Refer to section titled Charging Instructions The Hand control must also be connected to the floor lift If it is not connected then refer to the section titled Assembly Instructions 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 4 Technical Specifications 330 A Dimensions and Weight FGA 330 lift FGA 330 16 9 inches 42 8 cm
3. Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken 280420 FGA 330 Owner s Manual Complete this section after each service repair inspection and or maintenance Photocopy additional pages as required 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature Rev 11 18 12 Page 28 Service Record History Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspecti
4. 5 2 inches 13 3 cm 2 8 inches 7 2 cm 50 4 inches 128 cm 23 inches 58 6 cm 37 inches 95 cm 26 inches 66 cm 41 inches 104 cm Reach at maximum height 15 7 inches 38 8 cm Reach at minimum height 7 inches 17 8 cm Maximum Reach Distance between center of carry bar to front of the mast 22 8 inches 57 9 cm Turning radius Wheels dual wheel castors Weight of lit Total Shipping Weight with Box Folded Dimensions 2 Length Width Electrical Specifications FGA 330 lift Lift Motor 24 VDC 10 5 Amps Max Charger Input 100 240 VAC 50 60 Hz 0 4 Amps Max Charger Output 24 VDC 0 65 Amps Batteries 24 VDC 2 x 12 VDC 2 9 Ah Sealed Lead Acid Hand Control Electric Lifting Range 16 9 to 64 6 Lift Weight 79 2 lbs Maximum load of the floor lift is determined by referring Maximum Load 330 Ibs to the product label located on side of floor lift Duty Cycle 10 use 90 rest Rated Performance 30 lifts at 330 165 10 duty cycle Shipping Storage Conditions Normal Operating Conditions Temperature 40 to 70 C Temperature 10 to 70 C Relative Humidity 10 to 100 RH Relative Humidity 30 to 75 RH Atmospheric Pressure 500 to 1060 hPa Atmospheric Pressure 700 to 1060 hPa 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 5 Cautions Under no circumstance should FGA 330 portable floor lift and sling s be put in control of a person who has not been
5. Damp a cloth with isopropyl alcohol and wipe down entire exterior of lift No other chemicals and or liquids should be used to clean disinfect and sterilize this lift Caution Take great care to ensure that no liquids get inside the lift This lift is not drip proof or water tight Failure to protect the lift from liquids may result in damage to the lift and or may cause personal injury DON T Don t allow the batteries to fully discharge before connecting to the charger The batteries a lead acid gel cell type that can be trickled charged continuously batteries used for standby and have a high current discharge capacity Life 15 greatly reduced by deep or complete discharging of the bat teries Longer lifetime is obtained by maintaining fully charged batteries Don t continue to operate the handset by repeatedly pressing the buttons if the lift function will not move or the actuator will not function If this occurs then the actuator has either reached its end posi tion the load is too great or there is a malfunction Don t exert excessive force on the handset cable as this may break off the wires inside the cable prevent some or all of the operations Don t continually operate the hoist functions The system 15 not designed for continuous operation Continuous Operation will cause batteries to be deeply discharged or to damage the actuator or con trol box by overheating 280420 FGA 330 Owner s Manua
6. be turned off when not in use It is recommended that the lift be left on charge when not in opera tion Refer to the section titled Charging the lift for instructions on charging 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 19 Emergency Stop amp Lowering Caution The manual emergency lowering system should be used only if the lowering procedures de scribed in the previous section of the manual do not work Should you have any concerns or questions contact your local authorized Prism Medical Representative Emergency Stop Push the Emergency Stop button to cut all power on the Floor Lift To resume power release the emergen cy stop button by turning in the direction as indicated by arrows on the Emergency Stop button Electrical emergency lowering To operate the emergency lowering button on the control box insert a fine tip such as the tip of a ball point pen in the hole that is marked with a I symbol below Press and hold down The lift will continue lowering as you continue pressing down Release to stop the emergency lowering Emergency Stop Button Emergency Lowering Button Insert a fine tip such as the tip of a pen the hole that is marked with a symbol below Press and hold down The lift will continue lowering as you continue pressing down Release to stop the emergency lowering Mechanical emergency lowering In case of power failure it is possible to mechanically lower a pat
7. properly trained in the use and care of this equipment Failure to adhere to this warning may result serious injury to the operator and or the individual being lifted transferred The FGA 330 portable floor lift and sling 5 are not toys Do not use it for unsafe practices Do not allow children to play with the portable floor lift or any of its components The manufacturer s warranty is voided if persons unauthorized by Prism Medical Ltd will perform work on the FGA 330 portable floor lift There are no user serviceable parts inside the actuator Do not remove cover screws or open the unit as this will VOID THE WARRANTY In facilities where more than one operator will be responsible for using the FGA 330 portable floor lift and sling s it is imperative that all such members are to be trained in its proper use A training program should be established by the facility to acquaint new operators with this equipment Never expose the FGA 330 portable floor lift directly to water Warranty does not cover any mis use or abuse of the floor lift system To maintain optimum function the FGA 330 portable floor lift should be inspected and main tained on a regular basis See the section titled General Inspection and Maintenance Any accessories used with the FGA 330 portable floor lift including sling s should be checked to ensure that they are in good working order Check for signs of wear or fraying prior to
8. the leg and mast assembly by unfastening the restraining string from the mast L bracket as shown in Figure 3 and 4 This string will retract back into the bottom of the legs Figure 3 Figure 4 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 7 Assembly Instructions 4 Using push handle lift the Mast with Boom assembly upright and drop carefully into the base tube as shown in Figure 5 6 and 7 5 Using mast locking handles secure the lift mast in the upright position on the base assembly as shown in Figure 8 Tighten the mast locking knob as shown in Figure 9 Adjust the position of the locking handles pointing in downward direction towards the base of lift or ground as shown in Figure 9 Figure 8 Figure 9 Mast Locking Handles 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 8 Assembly Instructions 6 Open legs fully as shown in Figure 10 Make sure that leg locking knob inserts flush against the base as sembly and legs will no longer moves freely as shown in Figure 11 The legs will then only operate by the use of the foot pedal located at the rear of the base as shown Figure 12 Leg locking knob flush with the base assembly when the legs are fully opened Figure 10 Figure 11 Figure 12 7 Release carry bar from retaining cradle as shown in Figure 13 and 14 Unlock the rear casters Figure 14 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 9 Assembly Instruc
9. use Report any unusual wear or damage immediately to your local authorized Prism Medical Service Provider e The FGA 330 portable floor lift and associated sling s are intended only for lifting and transfer ring of a person Prism Medical will not be responsible for any damage caused by the misuse neglect or purposeful destruction of the lift and or its associated components In any circumstances do not exceed the maximum allowable load of this lift Refer to the Specifications section of this manual and or the labels on the side of the lift There is a risk of explosion if the lift is used in the presence of flammable anaesthetics e Ensure that a clear space is maintained around the lift Move any obstacles out of the way before opereating the floor lift 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 6 Assembly Instructions 1 Place the Carton Packaging box a clear working area open carefully and remove following items and place on the floor taking care to protect the finish from damage e FGA 330 portable lift in folded condition e Battery Pack Control Box and Charging Power Cord e Hand Control e Tool Kit User Manual and Test Certificate 2 Lift the FGA 330 carefully from the carton and place on the floor as shown in Figure 1 and 2 Lock the rear casters Remove the mast locking handles from the base tube as shown in Figure 2 Figure 1 Figure 2 Mast Locking Handles 3 Release
10. utilize leg opening function if required Lower the carry bar to a height so that the straps of the sling can be easily attached to the carry bar Caution Always check to ensure that the lift is correctly positioned directly above the per son to be lifted Caution Check to ensure that the carry bar has no cuts dents or sharp edges that may come in contact with the straps of the sling and cause damage to them Report any concerns to your local authorized representative Step 4 Attach the straps of the sling to the hooks of the carry bar The straps on each side of the sling are gen erally attached to the corresponding side of the carry bar Be sure to double check to ensure that the straps are properly attached to the carry bar and that the individual being lifted 1s properly positioned in the sling prior to lifting Caution Prior to lifting an individual make sure that the straps of the sling are securely placed on the hooks of the carry bar 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 18 Basics transferring an individual continued Step 5 individual may now be raised using the UP button on the hand control While lifting is in pro gress the height required in order for the transfer to be completed safely should be closely observed Ensure that the individual being lifted will not be injured by any obstructions during the initial lifting Caution Always use caution when lowering raisi
11. virtue of defects material or workmanship 2 This warranty does not apply to failure attributable to normal wear and tear damage by natural forces user neglect or misuse or to deliberate destruction or to batteries more than 90 days after original purchase 3 This equipment warranty shall be void if the equipment 15 not serviced by Prism Medical or its authorized service agents in accordance with the manufacturer s recommendations or if any unauthorized person carries out works on the equipment 4 The liability of Prism Medical under the terms of this guarantee shall be limited to the replacement of defective part s to the sales distributor dealer agent person or entity which purchased the equipment from Prism Medical In no event shall Prism Medical incur liability for any consequential or unforeseeable losses If you have any questions about the manufacture or operation of this equipment please contact Waverley Glen or your local authorized dealer PRISM MEDICAL SS 45 Progress Parkway Maryland Heights MO 63043 USA Phone 314 692 9135 Fax 314 692 7858 Toll Free 1 866 891 6502 www prismmedicalltd com This document conforms to EN ISO 10535 requirements Trade mark of Corven Health Care Inc Used under licence E amp 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 30
12. FGA 330 by Prism Medical teh ner lt 2 OVS VIS 2 Components of the Floor Lift 3 Component 4 SPECHICAUONS 5 6 Assembly Instruction 7 Disassembly Instruction 13 Operation 15 15 Forward 16 16 Leg 17 Raising and Lowering 17 Casters and 17 Basics in transferring 18 Emergency Stop amp 20 Technical Specifications 21 DO S and DOMNS 22 Trouble Shooting 23 General inspection and 24 Points of Attachment Checklist 25 Service record 26 VAE tutes
13. e of the control box as shown in the Figure 23 B Connect the Up down Actuator Cable connector to the second circle Marked No 1 from the left side of the control box as shown in the Figure 24 C Connect the Mains Cable Power Cord to the rectangular outlet on the control box as shown in the Figure 29 Figure 24 Figure 25 14 Please make sure to charge battery before initial use and before each operation of floor lift After assembly check to ensure that Legs are fully engaged and leg locking knob is flush with base tube The mast is fully locked into position The RED emergency stop button on control box is in the OFF out position Lifting actuator moving up and down with the buttons on the hand control and control box Emergency lowering mechanical and electrical function works properly Rear wheel brakes works properly Leg spreading foot pedal works properly Battery is fully charged 1 2 3 4 5 7 8 280420 330 Owner s Manual 11 18 12 12 Disassembly Instructions 1 Lower the mast to the lowest position as shown in Figure 26 and insert the carry bar into the retaining cra dle as shown in Figure27 2 Pull Leg Locking Knob away from the base tube as shown in Figure 28 and close the legs tightly together as shown in Figure 29 Figure 28 Figure 29 3 Remove mast locking handles as shown in Figure 30 and fold Mast amp Boom assembly careful
14. eps are intended to generally illustrate the procedure involved in the lifting and transferring of an individual from one location to another using the floor lift The manual for the sling that was purchased with the lift should be reviewed in detail prior to attempt ing these steps as the sling illustrated here may not be the same as the one that was purchased Contact your local authorized Prism Medical Representatives if you have any questions or concerns Step 1 Unplug the lift from its charging station or current location and move close to the individual that 15 to be transferred Use the procedures for up and down and transferring as described the sections titled Start Forward Movement and Turning Caution Always use extreme care when moving the lift from one location to another Watch out for and avoid any obstructions that may cause injury to the individual in the sling or damage to the lift Step 2 Prepare the individual being transferred with the appropriate sling Refer to the instructions supplied with the sling that was purchased on how to properly outfit an individual with a sling Caution Always make sure that the sling is correctly fitted and adjusted on each side of the individual so that maximum comfort and safety are achieved prior to lifting Step 3 Once the individual has been outfitted with the sling move the lift so that it 1s positioned directly over the individual and
15. feature Please Note The emergency stop must be released at all times during normal operation 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 15 Forward Movement To move the lift forward hold onto the handle bar and push forward Alternatively the caregiver can also place one foot on the base tube and push forward with their foot HANDLE BAR BASE TUBE Turning When turning the lift stand on along one side With one hand pull gently on the handle bar and with the other hand push gently away on the lifting arm In this way the lift will rotate around its own axis This movement is performed with a smooth slow action to avoid swinging the patient unnecessarily Warning 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 16 Leg Adjustment The legs of FGA 330 lift are mechanically adjustable for opening and closing base width The legs can be opened to enable access around arm chairs or wheel chairs For transferring through narrow doorways and passages the lift legs should be in closed position Leg adjustment is achieved by pressing the foot pedal located at the rear of base To open the legs press down the left side and to close the legs press down the right side as shown below Press Down Press Down to open the legs to close the legs Raising and Lowering the Boom The up and down movement of boom on FGA 330 lift 15 achieved by a powerful elec
16. fessionals to transfer clients The floor lift makes it possible to move mobility impaired individuals with minimal strain or risk to the caregiver while providing complete safety dignity and comfort for the client The FGA 330 portable floor lift 15 one of two components that make up this technology The other compo nent the sling is a specially designed fabric accessory that attaches to the floor lift by means of a carry bar and straps and holds an individual while the lift or transfer takes place The sling is generally supplied with the floor lift at the initial time of purchase Please refer to any user guides supplied with the sling and reference them while reviewing this manual The FGA 330 portable floor lift has the ability to lift an individual up from one location such as bed then move the individual to another location and finally lower the individual into a chair or bath The functions of lifting up or down or opening and closing the legs on the lift are accomplished by pressing buttons on the hand control The hand control 15 attached to the floor lift Due to the design of the floor lift system it takes very little effort to press a button to perform the desired motion Please familiarize yourself with the components of the FGA 330 portable floor lift by referring to the dia gram on the next page Model Table for FGA 330 Portable floor Lift Product Code Product Description 280420 FGA 330 Portable Aluminum Lift 330 Ibs
17. ient placed in FGA 330 lift In order to lower the boom in an emergency situation pull up the red lever located directly on the lift s ac tuator The boom will lower as you press up and hold the lever Release the red lever once you have low ered the boom to a safe position 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 20 Technical Specifications 330 Portable lift Specifications for FGA 330 Portable Lift 330 Ibs Max load and sa in Ibs and Dimensions in inch Max Folding Turning load Max as diameter Max load and weight in kg and Dimensions in cm Max ves Folding Turning load Min 63 max diameter 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 21 DO S amp DON TS DO Do charge the battery whenever possible This will extend the battery life A large number of cycles can be obtained from operating on the batteries but battery lifetime is reduced with frequent discharging v Do inspect all cables particularly the mains power cable on the charger for any damage replace where necessary v Do stow the handset and if fitted with charger the mains power cable when transporting the hoist v Do clean the actuators control box charger battery and handset at regular intervals to remove dust and dirt The exterior of the lift should only be cleaned disinfected and sterilized using isopropyl alcohol
18. ken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken 280420 FGA 330 Owner s Manual Complete this section after each service repair inspection and or maintenance Photocopy additional pages as required 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature Rev 11 18 12 Page 27 Service Record History Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type
19. l Rev 11 18 12 Page 22 Trouble Shooting Should problems arise with the use of the lift review the following chart Find the fault and complete the rec ommended solution If the fault is not found and or the solution does not correct the problem contact your local Prism Medical authorized Service Provider for service immediately PROBLEM SOLUTION Lift cannot raise lower control box is not clicking Hand control is not properly plugged in Hand control is defective Control box is defective Emergency stop button is not pushed in Mains cable is not plugged into the control box Lift cannot raise lower control box is clicking Lifting actuator cord 1 is not fully plugged into slot 1 on the control box Lifting actuator 1s defective Emergency Lower button on control box does not lower Lifting actuator cord 1 is not fully plugged into slot 1 on the control box Lifting actuator 1s defective Control box is defective Lift cannot spread or close legs Foot pedal is defective Cannot move lift e Rear caster brake is engaged Casters are defective Cannot tighten Mast into Base tube e Mast locking assembly are defective replace with new Mast locking assembly 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 23 General Inspection and Maintenance A Each Use To be completed by User e All functions on hand control are operational B Semi Annually To be completed at least every 6 month
20. ly toward the legs using the push handle as shown in Figure 31 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 13 Disassembly Instructions 4 Insert the mast locking handles into the base tube to avoid misplacement 5 Pull out the restraining string from the legs besides the front casters as shown Figure 32A and fix the string on the mast L bracket as shown in Figure 32 This will keep the legs mast and boom assembly together during transportation and storage Avoid pinching trapping fingers while fixing the string on the mast L bracket as the string has spring action Figure 32 Figure 32A 6 FGA 330 Portable lift is ready for transportation as shown in Figure 33 and for storage purpose as shown in Figure 34 Figure 33 A Caution During transportation remove the battery and hand control from the lift to avoid damage 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 14 Caution Visually inspect the floor before using for unusual wear and tear Should any thing look unusual then contact your local representative prior to use Failure to comply with this caution could result in serious injury to the operator the individual being lifted and or damage to the lift Because of the safety function in the actuator the lifting arm and hanger bar can fall down to the height of the spindle Therefore both before and after each lifting opera
21. ng an individual who is in the sling of the lift Watch out for and avoid any obstructions that may cause injury to the individual or dam age to the lift Step 6 Once at the correct height the individual can be moved to the desired location Refer to the sections already described in this manual on how to do so Step 7 Once at the desired location the individual in the sling can lowered raised to the correct height in order to complete the transfer On completion of lowering raising ensure that the individual is properly 1 tioned and safely supported prior to removing the straps of the lift from the carry bar A Caution Prior to removing the straps of the sling from the carry bar be sure to check that the individual being lifted is securely supported in the final desired position Step 8 Lower the carry bar sufficiently to allow the straps of the sling to be easily removed from the carry bar Take care not to let the carry bar come in contact with the individual in the sling The straps from the sling can now be removed from the carry bar The lift should then be moved away from the immediate area so that it will not interfere with the removal of the sling from the client Step 9 The sling can now be gently removed from the individual It should then be stored a safe place for future use Step 10 The lift can now be moved to a safe location until further use or relocated to its original location The lift should
22. on Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Taken 280420 FGA 330 Owner s Manual Complete this section after each service repair inspection and or maintenance Photocopy additional pages as required 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature 6 Month Inspection Repair o Yearly Inspection Other Signature Rev 11 18 12 Page 29 Warranty This Warranty does not affect or in any way limit your Statutory Rights 1 Prism Medical guarantees all equipment supplied as new against failure within the period of 1 year from date of purchase by
23. s Should any of these items fail the inspection do not use the lift Contact Prism Medical Systems or your local qualified service technician for service e Complete the inspection as noted the Each Use section above Also check the following e Battery charger functional e Weigh scale functional if applicable e Casters are clean and free of debris e All bolts and attachment points are secure see next page for Points of Attachment e Visual inspection of all weld points and cast components e Check operation of the emergency stop button C Annually To be completed at least every 12 months e Complete the inspection as noted in the Semi Annually section above Also check the following e Perform a working load test of one 1 lifting cycle with the maximum load This 15 in accord ance to the periodic inspection requirements of ISO10535 e Check functional operation of the emergency lowering mechanism e All bolts in connection with the carry bar must be inspected greased and tightened defec tive or worn components must be replaced e Connection bolts bearings between arm and mast to be inspected All defective or worn com ponents must be replaced e Leg spreading function to be tested and all bolts to be inspected All defective or worn com ponents must be replaced e Check that main actuator 15 functional 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 24 Floor Lift Points of At
24. tachment Use the described tools to tighten the bolts on a monthly basis in the areas shown 17mm Wrench Actuator mounting Smm Allen Key Push Handle 17 mm Wrench Carry bar mount 4mm Allen Key Mounting Bracket 3mm Allen Key Mounting Control Box 17mm Wrench Actuator mounting Locking Handle 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 25 Service Record History Initial Information Complete the following section on Purchase and Service Information as soon as this equipment is purchased Use the service record history to record to any completed service and repairs Ensure that the service record is signed and dated each time it 1s used Be sure to have this piece of equipment serviced on a regular basis as described in the General Inspection and Maintenance Section PURCHASE INFORMATION Product Name FGA 330 Bariatric floor lift Model Serial Date of Purchase Purchased From local authorized Prism Medical Representative Address City Postal Code Telephone No Comments SERVICE INFORMATION Contact the following company for service Company local authorized Prism Medical Representative Address City Postal Code Telephone No Comments 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 26 Service Record History Service Type Periodic Inspection Monthly Inspection Completed By Printed Name Company Remarks amp Action Ta
25. tion press the lifting arm down to ensure that it is supported by the actuator This must be done to remove the possibility of the lifting arm falling down and the risk of subsequent injury occurring Charging The light illuminates when you plug the control box to the power outlet and should turn off when it is unplugged The Charge light illuminates and when you connect the battery to the control box and it 1s charging as shown in the Figure 35 The Charge light will turn off when the battery is finished charging The lift should be plugged in for charging whenever the lift is not in use to get the max number of cy cles out of the battery An audible battery alarm will sound when approximate 50 of battery capacity remaining To obtain max life charge the battery at no more than 30 discharge Please Note The battery can be charged whether the Emergency Stop 15 activated or not Charging Indicator Light ON when Lift is charging Figure 35 Start The Hand Control has two functions up and down Press down on the symbols to operate the desired function It is not possible to use two functions at the same time An audible alarm will sound once the load becomes too great on the lift This will cause the lifting op eration to stop Do not continue to operate the handset by repeatedly pressing the buttons At this point the lift has reached it s maximum lift This is a purposefully built in safety
26. tions Detaching QRS Locking Carry Bar from the Lift 8 To detach the QRS Locking Carry Bar from Quick Release Hook Open the latch by pushing the latch down as shown in Figure 15 and 16 While keeping the latch pushed down Tilt the carry bar approximate ly 90 degrees and remove the carry bar from the quick release hook as shown in Figure 17 Figure 15 Figure 16 Figure 17 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 10 Assembly Instructions 9 Remove the middle screw from the mounting bracket using 3 mm Allan Key as shown in Figure 18 10 Press the FGA 330 CBJ Care Control Box against the mounting bracket and slide it down The control box should be seated securely on top of the edge of bracket as shown in Figure 19 11 Mount the Control Box to the mounting bracket using same screw that you removed from the middle of the bracket as shown in Figure 20 Figure 18 Figure 19 Figure 20 12 To install the battery you will need to press the battery against the bracket and slide 1 down until it sits straight on top of the control box as shown in Figure 21 Make sure to secure the battery box by latching the battery lock into the bracket as shown in Figure 22 Figure 21 Figure 22 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 11 Assembly Instructions 13 Connect all the cables to the control box as shown in the picture below A Connect the Hand Control connector to the large circle on the left sid
27. tric actuator which 1s controlled by hand control The hand control has two buttons with directional arrows UP and DOWN The actuator stops automatically at the limit of travel both directions Casters and Braking The FGA 330 lift has two rear casters with brake The rear casters can be braked for rotation lateral move ment and parking To apply the brake press the brake pedal down with your foot To release the brake press the raised pedal towards the wheel During the lifting the rear wheels should remain unlocked so that the lift will move to the patient s centre of gravity AN Warning Locked wheels during lifting will increase the risk of the lift tilting over Application If the lift is used incorrectly any warranty or product liability might cease to be valid The mobile lift must only be used for person lifting and only for persons who including the sling do not weigh more than the stated max weight load If the load exceeds the stated weight limit and if the lift 15 used for lifting anything but persons then any product liability that Prism Medical might have in connection with insurance warranty maintenance etc will cease to be valid To avoid possible accidents and injury to persons being lifted the floor lifts must only be operated as de scribed the preceding pages 280420 FGA 330 Owner s Manual Rev 11 18 12 Page 17 Basics transferring an individual A Caution following st