Application, SINAMICS DCM as field supply unit
Contents
1. Source actual speed value 0 p2118 0 60042 Selects that the fault message Tachometer fault is suppressed p2118 1 60035 Selects that the fault message Motor locked is suppressed p2119 0 3 Suppresses the fault message Tachometer fault P2119 1 3 Suppresses the fault message Motor locked 4 22 Version 2 Field supply with external setpoint Field supply unit p50076 0 Adaptation of the rated unit DC armature current scaling of the actual field current P50076 1 Adaptation of the rated unit DC field current Setting is not important as it is not used p50078 0 Setting of the rated line to line supply voltage for the power unit p50079 1 Enables the long pulses armature gating unit This is necessary for field supply from the armature terminals p50082 0 Internal field is not used p50083 4 Speed actual value can be freely connected p50084 2 Closed loop current controlled operation p50100 Rated armature current in this case the motor excitation current p50102 Setting is not important as it is not used P50153 3 Required for high inductances connected to the armature terminals p50179 gt 0 Additional alpha W pulses approx 3 n dependent on the size of the inductance p50192 1 Alpha W is always p50151 p50402 Current setpoint for standstill field 100 rated unit current of the armature circuit p50430 0 53010 0 Switches in th
2. 480 6 256 780 5 352 980 5 204 170 6 208 300 5 284 600 6 258 950 5 354 1190 5 222 220 6 226 360 5 224 280 6 228 450 1GG 1GG 1GG 1GG 1GG 1GH Ws 1GH Ws 1GH Ws 1GH Ws 1GH Ws 7 351 850 7 401 1400 5 402 1220 7 451 1350 5 500 1260 wf 352 960 7 402 1650 5 404 1500 7 452 1650 5 501 1740 wT 353 1200 7 403 1850 5 406 1700 7 453 2000 5 502 2060 wT 354 1380 7 404 2200 7 454 2400 5 503 2480 wT 355 1710 7 405 2700 7 455 3100 5 504 3070 b 631 2740 5 632 3430 b 633 4140 b 634 4680 b 635 5890 Trademarks All names identified by amp are registered trademarks of the Siemens AG The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described Since variance cannot be precluded entirely we cannot guarantee full consistency However the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions Siemens AG Industry Sector Postfach 48 48 90026 N RNBERG Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 Siemens AG Subject to change Industry Sector C98130 A7066 A501 03 7619 P O Box
3. Armature supply field supply Set the parameters according to the list from Point 4 3 When carrying out the automatic optimization runs the following sequence should be observed Field supply unit Procedure e Initiate the optimization run for precontrol and current controller i e set p50051 25 Enter the Switch on and Operating enable commands Wait until the optimization run has been completed Optimally set p50179 for the calculation see Chapter 6 Check the settings of the automatic optimization run when required subsequently optimize by evaluating the step response or by recording the control loop parameters using an oscilloscope or the trace monitor Armature supply unit Procedure p50082 0 Set for the duration of the optimization run p50051 25 Ensure that the field control unit cannot be switched on by opening X177 12 p50051 25 Carry out an optimization run for the precontrol and current controller armature Reset p50082 to the original value Switch on the field unit again P051 26 27 28 When required carry out the optimization runs for the speed controller field weakening and friction or moment of inertia compensation see SINAMICS DCM operating instructions Chapter 8 e Check the settings of the automatic optimization runs when required subsequently optimize by evaluating the step response or by recording the control loop parameters using an oscilloscope or the trace monitor e Additional setti
4. field I Switching on Ramp function n controller Torque Armature generator limiting Ex gating unit Armature current control Precontrol Field current control Overvoltage protection Application SINAMICS DCM as field supply unit 4 C98130 A7066 A501 03 7619 1 2012 3 2 Version 2 Field supply with external setpoint Field supply 1V1 1W1 3U1 3W1 O O O O O Current controller Switchover to standstill field O 4 z Switching on Ramp function n controller Torque Armature generator limiting gating unit Armature current control X177 25 Precontrol Field current setpoint external RATED Field current control Overvoltage protection Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 uonoejoJd aeon Jo uo99Jd Jo juo2eJd less 01 U09 I jueuno p j I puan piei4 h M li guu X i E 4 ll Bune6 piena cc l juiodjes juauuno pjal4 uonoeuuo 499d 0 199q Jo 3u05 uaino eunyeuly jojeis ab 1 yun 6une6 Bun Joyesauab jun 6une6 Bun uonounj uonoun enjeuuy enbio jejonuoo u diuear enjeuuy enbioj Jejoquoo u dwey LEH AH J lonuoo jueun2 JO4 U09 juauuno eJnjeuuv Kjddns p j Field supply armature supply 3 3 Version 3 C98130 A7066 A501 03 7619 1 2012 Application SINAMICS DCM as field supply unit 4 Parameter lists 4 1 Version 1 Field supply with
5. internal setpoint Field supply unit p50076 0 Adaptation of the rated unit DC armature current 7 scaling of the actual field current p50076 1 Adaptation of the rated unit DC field current Setting is not important as it is not used p50078 0 Setting of the rated line to line supply voltage for the power unit p50079 1 Enables the long pulses for armature gating unit This is necessary for field supply from the armature terminals p50082 0 Internal field is not used p50083 4 Speed actual value can be freely connected p50084 2 Closed loop current controlled operation p50100 Rated armature current in this case the motor excitation current p50102 Setting is not important as it is not used p50153 3 Required for high inductances connected to the armature terminals p50179 gt 0 Additional alpha W pulses approx 3 n dependent on the size of the inductance p50192 1 Alpha W always p50151 p50401 Setpoint operating field 100 96 rated unit current of the armature circuit p50402 Setpoint standstill field 100 96 rated unit current of the armature circuit p50430 0 53010 0 Switches in the standstill field via binary input terminal X177 11 1 standstill field p50431 0 52402 Setpoint routing for the standstill field p50433 0 52401 Setpoint routing for the operating field p50601 2 52209 Excitation current setpoint routing p50609 52000
6. supply with internal setpoint L L n aaa 4 Version 2 Field supply with external setpoint U L L L ener n u 5 Version 3 Field supply armature supply I L nnne erret nenne entree nennen nennen 6 Pararnieter iSts L Sa na w usai S EORR EYE hisua ESRE CHEER TUR E 7 Version 1 Field supply with internal setpoint I L L n n nn n u 7 Version 2 Field supply with external setpoint U enne n nn n u 7 Version 3 Armature supply field supply sssseseenenenen eene nnne rennen ennemi nnne 8 Armature supply field supply field reversal L n n eren enne nnns 10 Commissioning optimization runs a nennen nnne nnne nnn 11 Version 1 Field supply with internal setpoint l L emm nemen enne enne nnn nen nnns 11 Version 2 Field supply with external setpoint U L enm enemies 11 Version 3 Armature supply field supply L enne nen nenne nennen nnns 11 Setting the additional Alpha W pulses nnne nnne nnn 12 Overvoltage proteGtioft uu uuu 13 General information ere ren pee dees eee p ue ay eet aAA EEA AS EA EE na aya MER eo RR eR ayasa 13 Protection SINRQ VAarIlS OrS uu u S tects un M OR RU u a ie ES clo dae darle cn eet aa 14 Protection using
7. 48 48 Siemens AG 2012 90026 NUREMBERG GERMANY www siemens com automation
8. 9 1 Enables the long pulses armature gating unit This is necessary for field supply from the armature terminals p50081 0 or 1 when required field weakening dependent on the EMF p50082 24 External field unit ON via the p50082 0 Internal field is not used Auxiliaries ON signal p50083 4 Speed actual value can be freely connected p50084 1 Closed loop speed controlled mode p50084 2 Closed loop current controlled operation p50094 Switch off delay of the auxiliaries The time set here must be longer than the time entered in p50258 for the field current reduction p50097 0 Field current setpoint set to zero for a fault signal 1 field current setpoint not zero for a fault signal however it is not permissible to increase the field current setpoint p50102 Rated field current p50102 Setting is not important as it is not used p50153 3 Required for high inductances connected to the armature terminals p50179 gt 0 Additional alpha W pulses when a second pulse is enabled approx 3 n Dependent on the size of the inductance Application SINAMICS DCM as field supply unit 8 C98130 A7066 A501 03 7619 1 2012 Armature supply unit Field supply unit p50192 1 Alpha W always p50151 p50257 Standstill field The value should be kept at the factory setting 0 0 the reason for this is that when the field supply unit is switched off energy does not have to be dissipated via the overvoltage protection p50258 Delay
9. DCM armature supply unit master Signals are exchanged via a peer to peer interface The armature supply unit generates the current setpoint for the field supply unit and receives from the field supply unit the current actual value and fault signal Field weakening is possible Version 4 The same as version 3 however additionally with field reversal A 4Q unit should be used for the field supply unit in order to permit contactless changeover A warnine If the armature power unit is used to supply the field then it is absolutely necessary to provide overvoltage protection for the converter power semiconductors This is because if the input voltage is no longer present then the energy in the field circuit cannot be dissipated For version 4 with field reversal it is important to note that the overvoltage protection must be effective for both polarities In order not to unnecessarily load the overvoltage protection it should be ensured that when the pulses are inhibited the field current is already 0 for example this can be achieved by activating the standstill excitation as otherwise the remaining field energy must be dissipated through the overvoltage protection device Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 3 Block diagrams 3 1 Version 1 Field supply with internal setpoint Field supply 1V1 1W1 3U1 3W1 O O O O O Current controller Switchover to f standstill
10. SINAMICS DCM DC Converter Application SINAMICS DCM as field supply unit Edition 03 1 2012 SIEMENS E SINAMICS drives SIEMENS SIEMENS SINAMICS DCM Application SINAMICS DCM as field supply unit Compact User Manual Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety as well as to prevent damage to property The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring only to property damage have no safety alert symbol These notices shown below are graded according to the degree of danger indicates that death or severe personal injury will result if proper precautions are not taken A WARNING indicates that death or severe personal injury may result if proper precautions are not taken CAUTION with a safety alert symbol indicates that minor personal injury can result if proper precautions are not taken CAUTION without a safety alert symbol indicates that property damage can result if proper precautions are not taken NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account If more than one degree of danger is present the warning notice representing the highest degree of danger will be used A notice warning of injury to persons with a safety alert
11. a thyristor protection module L I n n enne nnns 14 Damping resistoriRS u s rt ee Sma Su d d Se A ee SE 15 Magnetic field energy for Siemens motors sse eene L L n uu 16 Notes Note This application document does not claim to contain all details and versions of units or to take into account all conceivable operational cases and applications The standard applications do not represent specific customer solutions but are only intended to provide support in the implementation of typical applications The operator is responsible for the correct operation of the products described Should you require further information or encounter specific problems which have not been handled in enough detail please contact your local Siemens office The contents of this application document are not part of an earlier or existing contract agreement or legal relationship nor do they change such contracts agreements or legal relationships The contract of sale in each case outlines all the obligations of the DT Drive Technologies Division of Siemens AG The warranty conditions specified in the contract between the parties are the only warranty conditions accepted by the DT Drive Technologies Division Any statements contained herein neither create new warranties nor modify the existing warranty Awearninc The units listed here contain dangerous electric voltages dangerous rotating machine parts fa
12. e standstill field via binary input terminal X177 11 1 standstill field Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 Field supply unit p50431 0 52402 Setpoint routing for the standstill field p50433 0 52011 Setpoint routing operating field analog setpoint from terminal X177 25 p50601 2 52209 Excitation current setpoint routing p50609 52000 Source actual speed value p2118 0 60042 Selects that the fault message Tachometer fault is suppressed p2118 1 60035 Selects that the fault message Motor locked is suppressed p2119 0 3 Suppresses the fault message Tachometer fault P2119 1 3 Suppresses the fault message Motor locked 4 33 Version 3 Armature supply field supply Armature supply unit Field supply unit p50076 0 Adaptation of the rated unit DC p50076 0 Adaptation of the rated unit DC armature current armature current scaling of the actual field current p50076 1 Adaptation of the rated unit DC field p50076 1 Adaptation of the rated unit DC field current current NOTICE Keep the factory setting Setting is not important as it is not used p50078 0 Adaptation of the rated line to line p50078 0 Adaptation of the rated line to line supply voltage of the power unit supply voltage of the power unit p50078 1 Not used p50078 1 Not used p5007
13. eld currents up to approx 500 A suitable for a current direction 2Q for 4Q use two in an anti parallel connection 7VV3003 5CG32 for field currents gt 500 A suitable for both current directions gt Operating instructions 7VV3003 http support automation siemens com WW view en 17635427 133300 Resistors Rs and Rv are not included in the scope of delivery of the thyristor protection modules They are only suitable for providing protection in the case of a fault When an overvoltage occurs the thyristor is fired by a BOD element break over diode and it remains conductive until the field energy has been dissipated and the thyristor holding current has been fallen below In order to prevent the field unit supplying the fired thyristor when the line supply returns the automatic SINAMICS DCM restart function should be deactivated set p50086 0 The following values are required to dimension the protection circuit e The highest load current that flows in operation e Time constant r of the free wheeling circuit L ptm R L Inductance of the motor field winding H R Total resistance of the field winding feeder cables series resistance when required Q T Time constant s The magnitude of the current and the time for which the current flows together determine the thermal load of the protective thyristor The permissible currents as a function of the time constant and notes on dimensioning a series resistance can be taken f
14. nding resistance in Ohm Vexc Rated excitation voltage in volts refer to the motor rating plate Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 13 7 2 Protection using varistors SINAMICS DCM Rs Damping resistor Varistor Field winding Metal oxide varistors for low energy content of the field winding Manufacturer Epcos company www epcos com Up to 420 V rated line supply voltage for 400 V SINAMICS DCM up to 400 Ws Varistor SIOV B32K460 up to 2000 Ws Varistor SIOV B80K460 Up to 500 V rated line supply voltage for 480 V and 575 V SINAMICS DCM up to 400 Ws Varistor SIOV B32K550 up to 2000 Ws Varistor SIOV B80K550 7 3 Protection using a thyristor protection module Rv series resistor when required Field winding Thyristor protection modules that can be supplied from Siemens The following thyristor protection modules are used for fields with an energy content gt 2000 Ws and field currents up to approx 2000 A Up to 420 V rated line supply voltage for 400 V SINAMICS DCM Order number E89110 F2439 L1 for field currents up to approx 400 A suitable for both current directions 4Q 7VV3003 5BG32 for field currents gt 400 A suitable for both current directions Application SINAMICS DCM as field supply unit 14 C98130 A7066 A501 03 7619 1 2012 Up to 500 V rated line supply voltage for 480 V and 575 V SINAMICS DCM Order number E89110 B2350 L1 for fi
15. ngs depending on the particular requirement commissioning the technological process Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 11 6 Setting the additional Alpha W pulses For highly inductive loads in spite of the fact that the Alpha W firing angle has been set full counter voltage to reduce the current in the inductance a certain time is required until the current has been completely reduced down to zero Especially for 4Q operation it is necessary that the current is zero and that the active thyristor reliably blocks before a torque direction change is made firing the anti parallel bridge circuit to reverse the current If the anti parallel thyristor bridge is fired before the previous one is reliably blocked then a circulating current flows and the appropriate fuses blow As a result of the low inductance for motor operation it is sufficient if the zero current signal is present the zero current signal is 1 of the actual rated unit current Uarameter r50072 1 to inhibit the pulses and after a short delay time to enable the opposite torque direction Motor generator fields or lifting solenoids often have inductance values of 10 H or higher This means that after the zero current signal is present a certain number of additional Alpha W pulses must be issued the number can be set using parameter p50179 until the current is zero It is absolutely necessary to make a theoretical check using the a
16. ns and control rotating mechanical parts drives Failure to follow the relevant Operating Instructions may result in death serious injury or extensive material damage Technical Support You can also find help for technical issues through our Technical Support www siemens de automation support request German www siemens com automation support request English 2 Siemens 02012 C98130 A7066 A501 03 7619 1 2012 2 Applications SINAMICS DCM units are used to supply the armature and field of DC motors The half controlled single phase bridge circuit fully controlled single phase bridge circuit as option integrated in the field power unit allows motors to be supplied with a maximum of 40 A 85 A from 6RA8093 1500 3000 A armature current as option rated field current If higher field currents are required then a SINAMICS DCM 2Q unit can be used whereby the pre controlled three phase bridge circuit normally intended to supply the armature is used to supply the field A distinction is made between four application cases in the following Version 1 The SINAMICS DCM unit operates completely independently a fixed internal field current setpoint is entered Field weakening is not possible Version 2 The SINAMICS DCM unit receives an external analog field current setpoint Field weakening can be realized using this setpoint entered externally Version 3 The field supply unit slave operates in conjunction with a SINAMICS
17. of rotation reversal by reversing the field From software version 1 2 and higher p50581 0 BOxxx Source for the command Braking by reversing the field From software version 1 2 and higher p50601 2 52134 Deviating from Point 4 3 here set the factory setting value 52134 p50433 0 52601 Excitation current setpoint from the armature unit p50671 0 52607 2 BO53195 1 from the armature unit Enable negative direction of rotation p50672 0 52607 1 BO53195 0 from the armature unit Enable positive direction of rotation p50694 0 52607 2 BO53195 1 from the armature unit Changeover torque limits p51117 1 53195 0 Select field torque direction 1 p51117 2 53195 1 Select field torque direction 2 p50609 0 52403 actual speed value from p50403 p50403 0 3 3 for r52403 p505370 0 5 n lt nmin threshold at 5 p50272 1 prevents F60043 10 Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 5 Commissioning optimization runs 5 1 Version 1 Field supply with internal setpoint e Set the parameters according to the list from Point 4 1 e Carry out an optimization run for the precontrol and current controller p50051 25 Refer to the SINAMICS DCM operating instructions Chapter 8 for the procedure 5 2 Version 2 Field supply with external setpoint The same procedure as for Point 5 1 5 3 Version 3
18. ppropriate calculations This is especially necessary in order to take into account a line supply undervoltage that may exist or for rated unit currents gt 60 A the resolution of the current actual value sensing referred to the thyristor holding current approximately 100 mA Calculation example V L xAi At At L x Ai V V DC output voltage of the SINAMICS DCM for a line supply undervoltage threshold and Alpha W V p50078 0 x 1 p50351 100 x 1 35 x cos Alpha W Ai 1 of the actual rated unit current r50072 1 From the zero current signal 1 of r50072 1 the additional Alpha W pulses are output At minimum time for Alpha W pulses 1 pulse 3 33 ms for 50 Hz or 2 78 ms for 60 Hz Example L 1 H p5078 0 400 V rated line supply voltage V p50078 0 x 1 p50351 100 x 1 35 x cos Alpha W for three phase operation V p50078 0 x 1 p50351 100 x 0 9 x cos Alpha W for single phase operation p50351 30 undervoltage threshold line supply Ai r50072 1 x 0 01 r50072 1 1200 A actual rated unit current Alpha W 150 degrees p50151 At 1 x 12 400 x 1 30 100 x 1 35 x 0 866 0 037 s Minimum number of additional Alpha W pulses at 50 Hz 37 ms 3 33 ms 12 20 allowance 12 x 1 2 14 4 gt set p50179 14 The value of the field circuit resistance R and the field circuit inductance L can be taken from the SINAMICS DCM parameters after the current controller o
19. ptimization run p50110 field circuit resistance in O p50111 field circuit inductance in mH Application SINAMICS DCM as field supply unit 12 C98130 A7066 A501 03 7619 1 2012 7 Overvoltage protection T 1 General information A warnine Overvoltage protection is absolutely necessary for this application as for example for a three phase voltage failure the thyristors could be blocked and an overvoltage could occur as a result of the energy contained in the field switching off an inductance This overvoltage can destroy the thyristors in the SINAMICS DCM unit Therefore the overvoltage protection has the task to limit the voltage to a defined value and to dissipate the energy in the field The following protective circuits are available e SIOV metal oxide varistors for low field currents e Thyristor modules NOTICE Metal oxide varistors SIOV MOV ZnO are designed to discharge high pulse energies in extremely short times The energy that is discharged is converted into heat stored in the varistor assembly and then slowly dissipated to the environment through the surface of the device As a result of the poor thermal conductivity and the higher temperature sensitivity under overload conditions metal oxide varistors can only be used with some significant restrictions for the high energy levels and the long time constants that occur when dissipating the energy in the field circuit When thermally ove
20. rloaded the varistor limit voltage permanently decreases If this frequently occurs then the varistor could be destroyed as there is a potential danger that the voltage limit could drop down to the range of the operating voltage Further a damping resistor Rs should be used to dampen overvoltages which can occur due to the pulsating current being interrupted oscillations or when the protection thyristor holding current is fallen below Maximum voltage limit to dimension the overvoltage protection Maximum permissible voltage limit dependent on the motor field winding and the rated supply voltage of the converter The lower value should be selected For Siemens motors maximum voltage limit 2000 V Rated line supply voltage for the SINAMICS DCM converter DC voltage limit at 1U1 1V1 1W1 3 ph 400 V AC 1350 V 3 ph 480 V AC 3 ph 575 V AC 1550 V 3 ph 690 V AC 1700 V 3 ph 830 V AC 2100 V 3 ph 950 V AC 2500 V Magnetic energy content of the field winding to dimension the overvoltage protection For Siemens motors the energy content can be taken from Chapter 7 5 If the energy content is not known then the field winding inductance is required to calculate it W L x lexc 2 Rexc Vexc lexc L 2 x W lexc W Magnetic energy content in Watt seconds L Inductance of the field winding in Henry lexc Rated excitation current in amps refer to the motor rating plate Rexc Excitation wi
21. rom the operating instructions for the E89110 overvoltage protection module The appropriate documents can be requested from Siemens ERL F98 IIS MS EDM ERL Frauenauracherstrasse 98 D 91056 Erlangen Telephone 49 0 9131 18 82329 Fax 49 0 9131 18 80604 7 4 Damping resistor Rs Dimensioning for a B6C connection 135xu v Rslo lt 0 5 A Urn IV Py W 2 3 x vIw R E UL Line to line voltage at the three phase connection of the converter Pv Power loss of Rs Urn Rated field voltage Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 15 7 5 Magnetic field energy for Siemens motors Average values of the magnetic field energy Ws when fully excited and with forced ventilation 1GF 1GF 1GF 1GF 1GF 1GG 1GG 1GG 1GG 1GG 1GH Ws 1GH Ws 1GH Ws 1GH Ws 1GH Ws 5 102 3 5 5 112 5 5 5 132 21 5 162 45 6 162 115 5 104 5 5D 114 8 5 5 134 30 5 164 60 6 164 150 5 106 7 5 116 12 b 136 35 5 166 75 6 166 190 5 108 10 1GG 1GG 1GG 1GG 1GG 1GH Ws 1GH Ws 1GH Ws 1GH Ws 1GH Ws b 182 100 6 186 185 5 252 340 6 256 540 5 312 730 b 184 125 6 188 220 5 254 430 6 258 690 5 314 910 5 202 140 6 206 250 5 282
22. symbol may also include a warning relating to property damage Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following A WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used these must be recommended or approved by Siemens Proper transport storage installation assembly commissioning operation and maintenance are required to ensure that the products operate safely and without any problems The permissible ambient conditions must be adhered to The information in the relevant documentation must be observed Siemens 02012 C98130 A7066 A501 03 7619 1 2012 1 Table of contents 1 2 3 3 1 3 2 3 3 4 4 1 4 2 4 8 44 5 5 1 5 2 5 3 6 7 7 1 7 2 7 3 7 4 7 5 1 Notl gSuuu roO RM RR Pan x OX ERE DOD RE ir Dedit bec T DUO ERROR FUNDI Su 2 PAO PUCAUONS Say mn na UU EM EUNT EE 3 Block diagralYl umum a n 4 Version 1 Field
23. time for automatic field current reduction The time set here must be shorter than the time entered in p50094 for the switch off delay of the auxiliaries p50601 2 52601 Excitation current setpoint p50609 52000 Source actual speed value p50612 52601 Excitation current actual value from the field supply unit via peer to peer p0840 0 52607 0 On command p0852 0 52607 0 Pulse enable p0844 0 52607 0 OFF2 initiated when the field supply unit has a fault condition p50790 5 Peer to peer selection p50790 5 Peer to peer selection p50791 22 Number of words transferred p50791 2 Number of words transferred p50793 8 Recommended baud rate p50793 8 Recommended baud rate p50795 1 Bus terminator on p50795 1 Bus terminator on p50794 0 52268 Excitation current setpoint p50794 0 52116 Absolute excitation current actual value p50794 1 52620 Routing auxiliaries on p50794 1 52620 Routing fault bit p50797 0 3 0 5 s Telegram failure time If a fault occurs when switching on the electronics power supply during the initializationo set a longer time p50797 0 3 0 5s Telegram failure time If a fault occurs when switching on the electronics power supply during the initializationo set a longer time p51117 0 53210 2 Auxiliaries on p51117 0 2139 3 Routing fault bit p51118 0 1 Fault bit inversion p51838 x
24. xxx Rated DC current of the external p2118 0 60042 Selects that the fault message field device corresponding to Tachometer fault is suppressed parameter r50072 2 of the external field device p2118 1 60035 Selects that the fault message Motor locked is suppressed p2119 0 3 Suppresses the fault message Tachometer fault P2119 1 3 Suppresses the fault message Motor locked NOTICE If field supply unit fault occurs then the armature supply unit is shut down with OFF2 the voltage is disconnected Application SINAMICS DCM as field supply unit C98130 A7066 A501 03 7619 1 2012 4 4 Armature supply field supply field reversal A 4Q unit is used for the field supply for this particular application In addition to the settings listed under Point 4 3 the following settings must be made Armature supply unit Field supply unit p50086 0 Deactivate the automatic restart so that the device does not switch to a conducting thyristor of the protection circuit p50150 5 Set the Alpha G limit to 5 degrees p50180 0 100 100 positive current limit for field direction 1 p50181 0 0 0 negative current limit for field direction 1 p50182 0 0 0 positive current limit for field direction 2 p50183 0 100 100 negative current limit for field direction 2 p50500 0 52193 Excitation current setpoint after limiting p50580 0 BOxxx Source for the command Direction