Home

JXDH-6102 Multiplexer User Manual - Jie

image

Contents

1. 110 220VAC 10 50Hz 2 5W 1 4 Principle Chart Ethemet PS232 4 TSInput 85 module 8 input module Controlling module Keyboard 4 v PID filtrate mapped TS adjusting Output module CH analyse select controlling multiplexing gt 4 v PID filtrate mapped TS adjusting Output module CH analyse select gt controlling multiplexina 1 5 Appearance and Description Front Panel Illustration JXDH 6102Multiplexer REA TARA A Power O A Enter Menu lt n Http WWWJIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd 1 LCD Display Interface 2 Power Indicator 3 Alarm Indicator 4 Input CH lock indicator 5 Up Down Left Right Arrow 6 Enter key 7 Menu Key Rear Panel Illustration AC110 220V 50 60Hz ASI N ASI OUT RS232 RJ45 00000000 COSO sae 1 2 3 4 5 6 7 8 Lon Loy O _ 8 ASI Input CH Output CH1 Output CH2 RS232 RJ45 AC Power Socket N OD oO A O TN Grounding Http WWWJIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd Chapter 2 Installation Guide 2 1 Acquisition Check When users open the package of the device it is necessary to check items according to packing list Normally it should include the
2. ehan FES JXDH 6102 Multiplexer User Manual V2 0 ChengDu Jiexun Electronics Co Ltd JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd Chapter 1 Product Outline 1 1 Outline JXDH 6102 multiplexer is a digital broadcasting TV system TS stream re multiplexer JXDH 6102 multiplexer combines several single programs or multiple programs which are compressed coded and multiplexed according to customer request by head end into single transport stream Besides it is also able to interpolate EPG Electronic Program Guide CA Conditional Access and digital broadcasting etc Maximally it can synchronal multiplex 8 route input code streams and support ASI interface The code rate of input code stream is maximally up to 270Mbps while code rate of four separate outputs code stream is maximally up to 155Mbps Through auxiliary data input channel lts dimension is standard 1U case By watching the LCD display on the front panel user can finish the setting of auto running of this device 1 2 Features Complying 15013818 standard Multiplexing SPTS and MPTS code stream 4 Support 8 single signal input 42 separate output support scrambled signal transmit free Draw out PSI SI from any channel Can point 256 PID in each channel Input at most 30 program each channel and 29 output redefine PAT PMT and other SI PSI Support PCR adjusting and PID re reflection Http WWW JIE XUN COM E mail JX JIE XU
3. Jiexun Electronics Co Ltd 3 15 Version Number When user select this setting the system will show as follows Hardware V1 0 Software V1 0 3 16 Language select When user select this setting the system will show as follows ADE English Press UP DOWN to select language the direct the selected one Default is Chinese version 3 17 Alarm Information When user select this setting the system will show as follows No Alarm Finish all the setting the multiplexer can operate normally 13 Http WWW JIE XUN COM E mail JX JIE XUN COM
4. be 1 2 1 5m and the distance to wall should be no less than 0 8m Electric Isolation Dust Free Volume resistivity of ground anti static material 1 107 1 1010 Grounding current limiting resistance 1M Floor bearing should be greater than 450Kg m2 5 40 C sustainable 0 45 C short time installing air conditioning is recommended 20 80 sustainable 10 90 short time 86 105KPa Installing rubber strip for sealing door gaps and dual level glasses for window It can be covered with wallpaper or brightness less paint Fire alarm system and extinguisher Requiring device power air conditioning power and lighting power are independent to each other Device power requires AC power 220V 50Hz 50W Please carefully check before running 2 2 3 Grounding Requirement All function modules good grounding designs are the base of reliability and stability of device Also they are the most important guarantee of lightning arresting and interference rejection Therefore system must follow this rule Coaxial cable s outer conductor and isolation layer should keep sound electric Http WWW JIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd conducting with the metal housing of device m Grounding conductor must adopt copper conductor in order to reduce high frequency impedance and the grounding wire must be as thick and short as possible m The 2 terminals of groundi
5. following items e JXDH 6102 multiplexer 1 e Users Manual 1 e ASI digital signal input and output wire 8 e AC Input Power Cord 1 If any item is missing or mismatch with the list above please contact local dealer 2 2 Installation Preparation When users install device please follow the below steps The details of installation will be described at the rest part of this chapter Users can also refer rear panel chart during the installation The main content of this chapter including m Checking the possible device missing or damage during the transportation a Preparing relevant environment for installation m Installing Encoder JXDH 6102 Multiplexer Connecting signal wires 2 2 1 Device s Installation Flow Chart Illustrated as following Connecting Acquisition Fixing Seals Connecting Setting Running Check gt i j Wire and gt j gt gt 3 Device ponen Signal Wire Parameter Device Cord Http WWW JIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd 2 2 2 Environment Requirement Item Machine hall space Machine hall floor Environment temperature Relative temperature Pressure Door amp window Wall Fire protection Power Requirement When user install machine frame array in one machine hall the distance between 2 row of machine frames should
6. N COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd Have the function of insert and reflection of SDT NIT Able to connect independent scrambler for scrambling to specified program or service Generating SPI SI information Support PCR adjusting and PID re reflection out put data rate 0 155Mbps 188 byte format Each input support 270Mbps data rate total 8 input rate is 576Mbps High precision PCR revise usually holding 20 60ns MPEG2 program delay less than 100us PID filtration PID redefine function User can delete add revise program even the program name PID or serials No easily Chinese and English LCD display Ethernet interface10 100M long distance control multiplexer via PC Have the function of parameter memory Have the function of PSI auto built High reliability design stable in running Alarm display Support network upgrade 1 3 Performance Index 8Routes Standard ASI Interfaces pub lntetase Maximum 270Mbps per route Re multiplexing MPEG 2 stream j PID re reflection Re multiplexing Automatically generating PSI SI table Output ASI 4 routes 2 gyoups separate output Http WWWJIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd Output PID range 0000 1FFF Random PID Random PID transparent transport transparent transport possbile 256 each input Miscellaneous 0 45 C Operating 20 80 C Storage
7. g and edit the parameters which needs modify or confirming the change after modification and turn over UP DOWN LEFT RIGHT Turn over Edit parameter MENU Lock Cancel Save Show current station 3 1 Main page Common station JieXun Electron Multiplexer V1 81 3 2 Press ENTER to main menu CA Output CH1 setting N 2 Output CH2 setting 3 Program search 4 System setting 5 Alarm Information 7 Press UP DOWN to select Http WWW JIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd 3 3 Output CH1 setting When user select this setting the system will show as follows do Port 01 Setting lb 1 2 Port 02 Setting 1 3 Port 03 Setting 1 4 Port 04 Setting 1 5 Port 05 Setting 1 6 Port 06 Setting 1 7 Port 07 Setting 1 8 Port 08 Setting 1 9 Output Rate 1 10 Trans stream ID 1 11ORG Network ID 1 12 Mux confirm 1 13 Mux No x A User can finish the select of program or parameter at each input port 3 4 Port 01 Setting When user select this setting the system will show as follows 1 1 1 Port 01 Number 1 1 2 Port 01 Mux If want to edit the TS of other ports select the related port will be ok 3 5 Output Rate When user select this setting the system will show as follows 1 9 Output Rate 100000kbps 3 6 Trans Stream ID When user select this setting the system will show as follows 10 Http WWW JIE XUN COM E mai
8. l JX JIE XUN COM JXDH 6102 User Manual 1 10 Trans Stream ID 0x0000 3 7 ORG network ID When user select this setting the system will show as follows 1 11 Original_network_ID 0x0000 3 8 Mux Comfirm When user select this setting the system will show as follows 1 12Yes Enter No T_ gt Menu 3 9 Mux Number When user select this setting the system will show as follows 1 13 Output 01 Mux Sum XX 3 10 Output CH2 Setting The same as the setting of CH1 3 11 Program search When user select this setting the system will show as follows 3 1 Auto All Search 3 2 Port Search 11 Http WWWJIE XUN COM Chengdu Jiexun Electronics Co Ltd E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd 3 12 System setting When user select this setting the system will show as follows 4 1 Network Setting 4 2 Factory config 4 3 Version Number 3 13 Network Setting When user select this setting the system will show as follows r IP Address 101 101 101 100 J di N Subnet Mask 255 255 255 000 J a N GateWay 101 101 101 004 J i N MAC Address 602020070505 3 14 Factory config When user select this setting the system will show as follows Press Enter Renew Press Menu gt Exit 12 Http WWWJIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu
9. ng wire must make sure for well electric conducting and process for antirust m tis prohibited that users use other devices as part of grounding wire s electric circuit The section of the conjunction between grounding wire and device s frame should be equal or greater than 25mm2 2 2 4 Frame Grounding All the machine frames should connect to protective copper strip The grounding wire should be as short as possible and avoid circling The section of the conjunction between grounding wire and grounding strip should be equal or greater than 25mm2 2 2 5 Device Grounding Connecting the device s grounding rod to frame s grounding strip with copper wire 2 3 Wire s Connection The power supply outlet is located at the left of rear panel and the power switch is just above it The protective grounding wire connective screw is located at the down left side of power supply outlet e Connecting Power Cord User can insert one end into power supply outlet while insert the other end to AC power e Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices 7 Http WWW JIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd When the device adopts united way the grounding resistance should be smaller than 10 Caution Before connecting power cord to Encoder user should set the po
10. wer switch to OFF 2 4 Signal Wire Connection The signal connections include the connection of input signal wire and the connection of output signal wire The signal connection wire are both ASI 2 4 1 ASI Input Connection User can find ASI IN1 IN8 input port on the Equipment according to connector mark described in the rear panel illustration and then connecting the Q9 coaxial cable one end to the ASI IN1 8 and the other end to the Encoder s or other equipment ASI output port 2 4 2 ASI Output Port Connection User can find ASI output port on the Equipment according to connector mark described in the rear panel illustration and then connecting the ASI cable in the accessories one end to the JXDH 6102 multiplexer s ASI output port and the other end to the scrambler s or Modulator s input port multiplexers ASI output port and its connected ASI cable connector illustrated as follow Http WWW JIE XUN COM E mail JX JIE XUN COM JXDH 6102 User Manual Chengdu Jiexun Electronics Co Ltd Chapter 3 Operation This JXDH 6102 multiplexer s front panel is user operation interface Before operating we should collocate input and output parameter Input setting includes the select of multiplexed channels output parameter includes setting of TS output Equipment supply perfect Chinese and English menu for user select detail operations go as follows Front Panel Keyboard Function Description ENTER Activatin