Home
IP Power Socket www.lindy.com
Contents
1. BIND Ye CONNECTION PERFECTION IP Power Socket Manual English www lindy com CEFE LINDY ELECTRONICS LIMITED amp LINDY ELEKTRONIK GMBH FIRST EDITION July 2012 User Manual Thank you for purchasing the LINDY IP Controlled Power Socket This product allows you to control the power of your devices over an IP based network Simply connect to a power supply and your local network then configure the device via a web interface Once configured the device can be switched using the buttons on the housing via SNMP commands or by customer created applications A web interface allows you to configure the device as well as review the energy consumption and other information An additional temperature sensor and humidity sensor can be connected to provide more detailed information Each port also has a watchdog function e P Controlled Power Socket e CD ROM containing software and user manual e This User Manual Connect the IP Power Socket to the power and wait for it to boot The LED will flash red green while booting and then stay red when ready to proceed Connect one end of the Ethernet cable to the Ethernet port of the IP Power Socket and the other end to an Ethernet port on your network Then connect the power cables from your device to the IP Power Socket LED Status e Red The device is not connected to Ethernet e Orange The device is connected to Ethernet but the TCP IP settings are not assigned e Green The device
2. Azione E HA FARE j KE iiia be HTTP pmid MITP Pos f TCP APS ergs by DHOP amp Era PACE P GEL posts debug Ace oMi fe ee u If the displayed IP address matches the factory settings 192 168 0 2 there is either no DHCP server available on the network or no free IP address could be allocated Enter a free IP address and then enter the Netmask address Then save the changes by clicking on Program Device gt SaveConfig You must restart the IP Power Socket for any changes to take effect Then click on Search and the new network configuration details will be displayed User Manual Configuration via web interface To configure the IP Power Socket via a web interface open an internet browser and input htto P address of IP Power Socket and presenter and then login To enter the configuration menu click Configuration on the upper left of the screen Configuration Power Ports Control Fan Gonguration Logo Fowerpods IP Address IP ACL HTTP SNMP Syslog E Mail Contiguration Powerports Choose Powerparn to configure Power Port Label Power Pont Initialization status Cam of C Remberlaststate Initialization delay FT Rapper delay ig Reset duration 10 Enable waichdog ves no Watchdog Tipe Crome toe Watchdog Action E Rasal C of Hosinarmie TCP Port leo Ping Interval in Ping Retries IE Apply IPower Control Plus Label A name with a maximum of 15 chara
3. Enter the interval time between two pings Ping retry Enter how many times a ping should be repeated before the power port is reset Configuration IP Address Configuration jani Fowarpots P Address IFACL HTTP SNMP Syslog r E Mail Configuration IF Address Hostname ERCHET 1x P Address r a 1881244 Metmask 2662662660 Gateway Address 119 168 13 ONS Address ap 16815 Use DHCP ys Cono Apply IPower Control Plus User Manual Hostname Enter the Hostname you would like to use This is the name the IP Power Socket will use to connect to the DHCP server Try not to use any special characters as this may de stabilise your network IP Address You can manually input an IP address Netmask You can manually input a Netmask ID Gateway You can manually input the Gateway address Use DHCP If there is no DHCP server on your LAN we recommend you deactivate this function You must restart the IP Power Socket for any changes to take effect Configuration IP ACL Connu Carina been Legaui Powenorts P Address IPACL HTTP SNMP Syslog E Mail Configuration IP ACL Reply ICMP Ping requests doi Co 1 Grant IP access to Hostitel Kiss Galata add Apply IPower Control Plus The IP ACL IP Access Control List acts as an IP filter for your IP Power Socket You can set it so only active hosts and subnet IP addresses listed can access the IP Power Socket If you have locked y
4. cters can be entered for each power port Initialisation Status You can define the ports switching state after powering up on off remember last state Initialisation Delay You can delay the switching on of a port by up to 8191 seconds Repower Delay If this function is enabled the power port can be reactivated after a stated time from switching off User Manual Watchdog Electrical devices can be observed while Watchdog is running Watchdog sends ICMP pings or TCP pings to the device if the pings are not answered during a defined delay timed or pings the power port will reset You can also restart any attached crashed systems or NAS systems using the Watchdog function When watchdog is activated it sends a ping and waits for a reply During this time the text will be orange When it receives the first ping the text will turn green When a power port has been reset Watchdog will send a ping and wait for its first reply e Green text Watchdog is active and is receiving ping replies e Orange text Watchdog is activating and is waiting for the first ping reply e Red text Watchdog is active and does not receive ping replies any longer Enable Watchdog Activate Watchdog on this power port Watchdog type Switch between ICMP ping or TCP ping Host IP Enter the IP address you want Watchdog to monitor TCP Port Enter the TCP port number when using TCP pings When using ICMP pings a TCP port number is not needed Ping interval
5. hersteller France En 2006 l union Europ enne a introduit la nouvelle r glementation DEEE pour le recyclage de tout quipement lectrique et lectronique Chaque Etat membre de Union Europ enne a mis en application la nouvelle r glementation DEEE de mani res l g rement diff rentes Veuillez suivre le d cret d application correspondant l limination des d chets lectriques ou lectroniques de votre pays Italy Nel 2006 l unione europea ha introdotto regolamentazioni WEEE per la raccolta e il riciclo di apparecchi elettrici ed elettronici Non pi consentito semplicemente gettare queste apparecchiature devono essere riciclate Ogni stato membro dell EU ha tramutato le direttive WEEE in leggi statali in varie misure Fare riferimento alle leggi del proprio Stato quando si dispone di un apparecchio elettrico o elettronico Per ulteriori dettagli fare riferimento alla direttiva WEEE sul riciclaggio del proprio Stato LINDY No 32672_3 1 Edition July 2012 www lindy com
6. hland hinaus eine zweij hrige Hersteller garantie ab Kaufdatum Die detaillierten Bedingungen dieser Garantie finden Sie auf der LINDY Website aufgelistet bei den AGBs X WEEE Waste of Electrical and Electronic Equipment Recycling of Electronic Products Europe United Kingdom In 2006 the European Union introduced regulations WEEE for the collection and recycling of all waste electrical and electronic equipment It is no longer allowable to simply throw away electrical and electronic equipment Instead these products must enter the recycling process Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways Please follow your national law when you want to dispose of any electrical or electronic products More details can be obtained from your national WEEE recycling agency Germany Deutschland Die Europ ische Union hat mit der WEEE Direktive Regelungen f r die Verschrottung und das Recycling von Elektro und Elektronikprodukten geschaffen Diese wurden im Elektro und Elektronikger tegesetz ElektroG in deutsches Recht umgesetzt Dieses Gesetz verbietet das Entsorgen von entsprechenden auch alten Elektro und Elektronikger ten ber die Hausm lltonne Diese Ger te m ssen den lokalen Sammelsystemen bzw rtlichen Sammelstellen zugef hrt werden Dort werden sie kostenlos entgegen genommen Die Kosten f r den weiteren Recyclingprozess bernimmt die Gesamtheit der Ger te
7. is connected to Ethernet and it is ready to use e Blinking red green The device is in Bootloader mode Configuration Bootloader Mode In Bootloader mode it is possible to disable password function update the firmware and restore the default settings using the GBL_Config exe program To activate Bootloader mode press the button while restarting the device If the device is already running press select and OK for 3 seconds The Bootloader mode will be indicated by the BOOT LDR name change in the window of the GBL_Config exe application User Manual To restart the firmware without toggling the power ports press select and OK for 3 seconds again DHCP When you switch on the IP Power Socket it will automatically look for a DHCP server and request an available IP address Check the IP address allocated to the device by the DHCP server is the same after every reboot Network Settings To edit the network properties manually you will need the program GBL_Config exe This program is available on our website www LINDY com Activate Bootloader and run the GBL_Config exe application The program will automatically look for any connected devices and display their network configuration LM Cor e a 1 143 Search neteork devices li Banane u ur e zu m Eu Base ee Ve DI GEL are Firma Won 2 Bai Leon CU por DE Qu LE EL Goie wi achm cer pus sub T desi brel Heat re HAE Er STE IP
8. nd start the GBL_Config exe application then deactivate the password request User Manual Configuration Messages Geniessen Mestages IPower Control Plus Configuration Messages IPower Control Plus Generate Messages Select yes or no to configure the device to send alerts via SNMP and Syslog Max Value The sensor will measure the value inputted and generate an alert via SNMP and Syslog Min Value The sensor will measure the value inputted and generate an alert via SNMP and Syslog User Manual Configuration Syslog Coca Parsi Corfiguralion Fowerports IF Address IP ACL HTTP SNMP Syslog E Mail Configuration Syslog Enable gyelog i ves Lp no Syslog server IPower Control Plus Note Syslog messages are simple text messages transmitted to a Syslog server using UDP Linux OS regularly have a Syslog daemon installed e g Syslog ng For Windows there are some freeware tools available On the following events the IP Power Socket will send a Syslog message e Booting up e Activation deactivation of Syslog e Switching of Power Ports Enable Syslog Select yes or no to enable the Syslog Syslog Server IP Input the IP address of your Syslog server Syslog Port Input the port number of the Syslog server Sensor additional option The temperature hybrid sensor can be purchased separately Connect the sensor to the DIN socket on the front of the device When connected the most recent measurement
9. ourself out by mistake activate Bootloader mode and start the GBL_Config exe application then deactivate IP ACL Reply ICMP Ping requests Select yes if the IP Power Socket should react to pings Enable IP Filter Enable or disable the IP ACL DHCP and SNMP will only work when the IP ACL is active and if all the necessary servers and clients are registered in this list User Manual Configuration HTTP Fowernpans IP Address IPACL HTTP SNMP Syslog E Mail Configuration HTTF HTTP Fort lan Enable HTML Aytorefreshi fr yes E no Regui HTTP Passend im yee rc no Check Password on Start Page Cron n Fal nea adn password repeat sone password Sel note ina password piil H e Dad Apply IPower Control Plus HTTP Port Enter a number from 1 to 65534 standard 80 To access the IP Power Socket input the port number after the IP address e g http 7192 168 0 2 80 Check Password on Start Page If activated the user must enter the password before logging in to the web interface Require HTTP Password Choose yes or no to have password protected access When choosing yes you must input a User and Admin password The password cannot be more than 15 characters long Username Admin Administrators are authorised to switch all ports and to modify settings Username User Users are able to switch all ports but are not allowed to modify any settings If you forget the password activate Bootloader mode a
10. will be displayed in the login window User Manual Cable ongt 20 100C 2 max and 1 typical Hybrid sensor Cable length Connection Mini DIN Measurement 20 80 Grad 0 5 Moisture 0 100 3 Firmware update To update to the latest firmware start the device in Bootloader mode and start the GBL_Config exe application When the program is running the devices in the network will be listed on the left of the screen Select the device to be updated click on Program Device Firmware Update and navigate to the location of the new firmware Please contact LINDY for the latest version of the firmware and GBL_Config exe CE FCC amp Recycling Information CE Certification This equipment complies with the requirements relating to Electromagnetic Compatibility Standards EN55022 EN55024 and the further standards cited therein It must be used with shielded cables only It has been manufactured under the scope of ROHS compliance CE Konformit tserkl rung Dieses Produkt entspricht den einschl gigen EMV Richtlinien der EU f r IT Equipment und darf nur zusammen mit abgeschirmten Kabeln verwendet werden Diese Ger te wurden unter Ber cksichtigung der RoHS Vorgaben hergestellt Die formelle Konformit tserkl rung k nnen wir Ihnen auf Anforderung zur Verf gung stellen LINDY Herstellergarantie Hinweis f r Kunden in Deutschland LINDY gew hrt f r dieses Produkt ber die gesetzliche Regelung in Deutsc
Download Pdf Manuals
Related Search
Related Contents
CONSIGLI SULL` USO E MANUTENZIONE PER Samsung NZ64H37070K Płyta indukcyjna Philips VR6291 User's Manual tM-P4C4 User Manual Bedienungsanleitung STARKPOWER Acessórios smart & acessórios BRABUS 2011 Copyright © All rights reserved.
Failed to retrieve file