Home

Manual AlphaApp.xlsx

image

Contents

1. This menu shows all the system temperatures Flow Shows the currently measured flow temperature of the heat pump Retun Shows the currently measured return temperature of the heat pump targeted Return Shows the currently targeted heating circuit temperature which is determined according to the heating curve Return external T Shows the currently measured Return temperature in the Storage or Buffer tank When connected the stratified storage tank sensor or the series buffer tank sensor provides the temperature value for regulating the heat pump Current DHW temperature Amb temp Current Ambient temperature The temperature information menu may also be accessed by swiping the main screen right Shows the heat pump s operating hours The operating hours menu may also be accessed by swiping the main screen top down Error memory data logger Settings Saves the last five errors including date and time of the error occurring The error memory may also be accessed by swiping the main screen bottom up The data logger stores and graphically displays the course of different temperatures and operating modes Swiping the screen from top down brings up a explanation of the different graphs plus the scale options The data logger displays show the following values Operating modes We iif heating Bt cooling 128 DHW K second heat generator active B Swimmingpool temperatures current flow tempera
2. Alpha InnoTec The AlphaApp The AlphaApp enables you to access your heat pump from everywhere you go The App is very easy to use and provides easy access to all the important functions of your heat pump If you don t own a heat pump yet you can use the App anyway The App contains a demo mode heat pump which simulates the relevant functions of a real system You can either use a local area network to establish a real time connection between the App and your heat pump or your AlphaWeb access to connect via the Internet An AlohaWeb account is very useful combined with this App but it is not necessary for a local area network connection alpha iio lec If used with an AlphaWeb account the AlphaApp also is a very useful tool for customer service Due to the ability to access the heat pumps linked to your account online you can get information such as occurred errors the system status and all important settings from everywhere you are wil Taelekom de E Oo 20 Back Selection The demo mode As we already mentioned the App also provides a demo mode in case you don t own a heat pump on your own Using the demo mode you are able to test all important functions of the App The demo mode is started by selecting the demo heat pump in the heat pump selection menu When in demo mode you can try out all the options but you can t save changes Connecting to an AlohaWeb account As yo
3. mode for each DHW circuit on its own The following options are available here Auto Automatic operation If set to second heat gen the second heat generator is activated The heat pump s compressors are inactive when this mode is set Party If set to Party the heat pump will ignore all timers and remain in the normal operating mode until the party mode gets deactivated Holidays If set to holiday mode the heat pump will lock the DHW preparation mode to off for the designated period of time Turns off the DHW mode completely Timers Setting timers This symbol opens up the timer menu for the linked operation mode Depending on the display tilt the menu will either show a clock like interface or a table Section Week Mo Su When the device is held Week Mo Su upright the timers can be s Week Mo Su When turned to a set as seen in the 16 45 20 00 horizontally position the bystanding picture The red 09 45 14 30 timers can be set in a table areas enclosed by the as shown here white brackets show the designated period of time for the operation mode to be active 22 45 05 15 Heating timer settings The timers can be set for each heating circuit on its own After selecting the heating circuit one of the following options may be chosen The Week option allows you to set up to three timers which then are valid for every day of the week The selected timers refer to the normal operation mo
4. Then scroll down and select Control panel L Date and Time Screed heating Heatpump configuration Startup guide ie dats logger Control Panel Control Panel Select IP adress dizplay contrast Webserver IP address P address In the IP adress menu you can read the heat pumps IP adress Make sure both your mobile device IF j Hdi Fod and your heat pump share the same subnet sJbnetmask Cu Cy 1 1 T broadcast Bo a a gatera Le WI BS z 1 1 vet ao et eet If you set up the controller IP correctly the AlphaApp should now show your heat pumps IP in the selection menu For reloading the menu hit the Back button The real time connection to your heat pump is established by selecting its IP AlohaApp users guide After selecting a heat pump the Apps main page is shown The main page shows the actual operation mode of the heat pump the ambient temperature and if the connection was established via AlphaWeb the time of the last actualization Temperatures Operating hours Auswahl Ambient Temperature operation mode operation mode state v Operating mode available no errors occured If symbol is flashing the operating mode is currently active Operating mode set to off Operating mode demanded but unexecutable due to Timer Update time restrictions etc Homepage An error has occured DHW menu heating menu information when connected via AlphaWeb
5. de meaning the heat pump will be in lowered operation mode during the left time period The targeted temperatures of the lowered operation mode can be found in the heating curves and the control panel of the heat pump and can not be modified via the App a i MORSA The 5 2 option allows you to set up to three timers each for Mo Fr weekdays and for Sa Su weekend u Days Mo Tu The days option allows you to set up to three timers per day for each day of the week DHW timer settings The timers of the DHW operation mode are lockdown timers meaning the DHW preparation is set to off during the designated time periods The Week option allows you to set up to three timers which then are valid for every day of the week The selected timers will set the DHW preparation to off during the preset time 5 2 Mo Fr Sa Su The 5 2 option allows you to set up to three timers each for Mo Fr weekdays and for Sa Su weekend u Days Mo Tu The days option allows you to set up to three timers per day for each day of the week The Alpha InnoTec InApp support page Touching the Alpha InnoTec logo on the main page brings up the AlphaApp web support page on the Alpha InnoTec homepage Additional to a quick explanation of the main page symbols and the user s manual download link the page also provides several FAQ s concerning the App If your question isn t answered by the FAQ s don t hesitate to contact our tech sup
6. port via the enclosed e mail address We will then contact you to solve your problem asap The homepage also features lots of information not only about heat pumps but also about ventilation systems and solar heating energy
7. ture current return temperature current DHW tank temperature ambient temperature the settings icon brings up a menu for altering the operation mode and or temperature values The settings icon can be found in all the different operating mode menus and provides setup options according to the operation mode Settings in the heating menu Operation mode This option allows you to alter the operation mode for each heating circuit on its own The following options are available here Auto Automatic operation second heat gen If set to second heat gen the second heat generator is activated The heat pump s compressors are inactive when this mode is set Party If set to Party the heat pump will ignore all timers and remain in the normal operating mode until the party mode gets deactivated Holidays If set to holiday mode the heat pump will lower the targeted heating temperature for the designated period of time Off Turns off the heating mode completely The heating settings menu may also be accessed by swiping the main screen left temperature The temperature value works as an offset for the heating curve It can be modified from 5 C to 5 C Beeing an offset the value modifies the heating curve by the set value So if a value of 5 is chosen the heat pump will add 5K to the targeted system temperature during the whole season DHW menu settings operation mode This option allows you to alter the operation
8. u already know a connection to your heat pump can be established via your AlphaWeb account If you don t have an AlphaWeb account you should skip this section In the following a step by step user s guide will show you how to acces your account with the App Re Fotos amp Kamera gt Lj iBooks gt in Podcasts gt gs itunes U gt wv Twitter gt f Facebook gt aA Adobe Reader gt J AlphaApp gt First select the AlphaApp in your device s settings menu as shown above AlphaWweb Use AlphaWeb ON Q Login Beanulzemame Passwort PIrTiTiiiii In the following menu you will be asked to enter your AlphaWeb account information Be sure to flip the use AlphaWeb switch to on The App needs to be restarted in order to connect to AlphaWeb by double clicking the HOME button and then clicking the App Selection heatpump 1 heatpump 2 When the login was successful the heat pump selection menu will show g your heat pump after restarting Connecting via local area network You also can connect your heat pump via local area network Therefore you will need to check some settings in your Luxtronik 2 0 heat pump controller To check your IP settings follow the upcoming instructions Hest pump comes At first click the wrench symbol in your heat pumps main screen to bring up the service menu In Oot net input delay i iiA s e Service Cer Tice

Download Pdf Manuals

image

Related Search

Related Contents

LES RENDEZ-VOUS - Saint  IGWeb 2008  保護署の方へ 謡ずお読みくださし  Manual de instrucciones del reloj de copiloto de rally  Tripp Lite Displayport to DVI Cable, Displayport with Latches to DVI-D Single Link Adapter (M/M), 10-ft.  SH-03E取扱説明書詳細版  Nuestras más sinceras felicitaciones por la compra de su  Les sorciers blancs  広報 川 越 №1329  Mode d`emploi  