Home

Wi-Fi RIB User Manual - Functional Devices, Inc.

image

Contents

1. Contact Ratings 20 Amp Resistive 277 Vac 20 Amp Ballast 277 Vac 16 Amp Electronic Ballast 277 Vac N O 10 Amp Tungsten 120 Vac N O Device Settings Local Override Reset to Network Defaults Pushbutton Power Input Green LED Wifi Ad Hoc Status 2 HP 277 Yellow LED Wifi Infrastructure Status 120 Vac 24 Vac Terminal Strip 20 Vac min 28 Vac Green LED Device Status 24 Vdc Terminal Strip 24 min 28 max Red LED Relay Status Dimensions 4 28 x 7 00 x 2 00 with 75 NPT Nipple Power Input Ratings Approvals UL Listed 11916 C UL 200 mA 24 Vac Device Settings NEON Housing Rating FCC CE RoHS Wifi Certified ASD Device UL Accepted for Use in Plenum NEMA 4 200 mA 24 Vdc Gold Flash No Relay Override Switch DIP Switch Control Available TCP IP Settings Wifi IEEE 802 11 b g n Compatible G IP Address Static 54 Mbps Data Rate 95 dBm Min Sensitivity 16 dBm Max Output Power Currently Unsecured Connection in Ad Hoc WPA PSK or WPA 2 PSK Available Supports PING and ARP DSSS Modulation Port Number Subnet Mask Gateway Address e Ad Hoc mode e Infrastructure mode Scan for wireless networks Power up default relay state Host name and location labels Relay bound to digital input 11 Devices Inc RIBTW24B WI N4 BULLETIN CONT Wi Fi RIB Getting Started
2. 277 Vac 16 Amp Electronic Ballast 277 Vac N O 10 Amp Tungsten 120 Vac N O 1110 VA Pilot Duty 277 Vac 770VA Pilot Duty 120 Vac 120 Vac 2 HP 277 Vac Power Input Ratings 158 mA Max 24 Vac 110 mA Max 24 Vdc 55 mA 120 Vac Available TCP IP Settings Address Static Port Number Subnet Mask Gateway Address Ad Hoc mode Default e Infrastructure mode Scan for wireless networks CAUTION Remove all connections to UI 1 and UI 2 when setting input Universal Input Configurable by internal device web page accessible in either Ad Hoc or Infrastructure Analog value returned user configurable min and max scale and label 0 5 Vdc 0 10 Vdc or 4 20 mA Direct temperature reading from Type 2 Thermistor Connect between 5 Vdc and UI input Digital Input connect between 5 Vdc and UI input C US LISTED C PUYO QA rs a Made in USA Meets Buy American of ARRA 2009 e mm RIB Wi Fi RIB Code Version 4 0 9 1 0 Device Settings Local Override Reset to Network Defaults Pushbutton Power Input 24 Vac Terminal Strip 20 Vac min 28 Vac max 24 Vdc Terminal Strip 24 Vdc min 28 Vdc max 120 Vac Wht Blk Wire Neutral Wht Yel Wire Device Settings by Network Power up default relay state Host name and location labels Relay bound to digital input Username and Password
3. Functional _ Devices Inc USER MANUAL Om om Wi Fi RIB EXPAND YOUR NETWORK EXPAND YOUR CONTROL a EN E255 SEES m i itii i Devices INC RIBTW24B WI N4 What is a Wi Fi RIB Our Wi Fi RIB is the I O device for the next wireless generation of Building Automation amp Energy Management Systems The Internet of Things is happening today and Functional Devices is proud to introduce their new Wi Fi RIB offering the ability to turn devices on off wirelessly as well as monitor your network remotely Our Wi Fi RIB can be used in an individual Ad Hoc setting or implemented into a much larger Building Automation System where many of the devices can be active Why use a Wi Fi RIB As technology continues to move forward in the wireless applications of Building Automation amp Energy Management Systems the more reason to use a Wi Fi RIB is evident By using a Wi Fi network setup can become easier and less expensive than the traditional hard wire used in previous networks By incorporating our Wi Fi RIB into your network devices can easily be installed in those hard to get to places especially for retrofit applications Where would you use a Wi Fi R
4. 3 5 Y 24V Opti 2 8 ptional 5 u 5 Voltage O 24Vac Power Input z 24Vac dc 3 24vdc Relay Contacts Term A Not used 2 120 Vac Optional Term Neut Power Input IEEEE 802 11 b g n compatible 120Vac Relay Contacts 54 Mbps Data Rate Input 1 SPDT 20Amp IP Static Address Voltage Devices Inc Ad Hoc Wireless Application PC MAC Single Zone Application BAS CONTROLLER s MEA S I caps ue Functional 4 Devices using Gateway BAS CONTROLLER GATEWAY DEVICE Single Wireless Zone Application _ Functional _ d W Devices Inc w Multi Device Multi Zone Application Wireless Zone a e SWITCH a GATEWAY DEVICE Boo 8 ew a 1 RIB RIB Functional 2 Devices Inc Multi zone Application using Proprietary Software Software SWITCH Proprietary Software SWITCH 07 Functional Devices Inc Long Distance Control 5 5 Exp ep BAS BRIDGE BRIDGE CONTROLLER ROUTER 5 a a a a a a a Y EJ Devices Inc Energy Savings Application Wireless Temperature Control PC SOFTWARE BASED I
5. the computer to connect to the same network to find the Wi Fi RIB Once Wi Fi RIB is connected to a router you must wirelessly connect the laptop or controller to the same router to see and control the Wi Fi RIB since it s on different network Device LEDs A description of all LED indications e Green Device Status LED Flashes at rate of once per second LED will be on 1 2 second and off 1 2 second Hesitation in LED may be seen when the Wi Fi RIB is answering HTTP commands e Green Ad Hoc Status LED On solid while in Ad Hoc mode LED will be off when in Infrastructure Mode e Yellow Infrastructure Status LED Flashes at rate of once per second LED will be on 1 2 second and off 1 2 second when Wi Fi RIB is searching for router either during original connection after power cycle of router or Wi Fi RIB or network activity intended to disconnect Wi Fi RIB LED will be off when in Ad Hoc Mode e Pink Digital Input Status LED On if Digital Input is closed off if open e Red Relay Status LED On if relay is activated closed N C open off if deactivated open N C closed Sources of Relay Control and Order of Precedence The relay may be controlled over the Wifi network by the web page or HTTP commands by the general purpose Digital Input if binding is set to Bound on the setup page or manually by the override DIP switches on the Wi Fi RIB The Digital Input if binding activated takes preceden
6. w RIB f F RIB L i E X Unit Ventilators Classroom Wi Fi RIB Installations RIB Functional Devices lnc Energy Savings Application Building Automation System RIBTW24B WI N4 Access Point Air Handling Unit Automated Demand Response Load Shed Application 10 Functional Devices lnc RIBTW24B WI N4 BULLETIN RIBTW24B WI N4 Network Compatible Relay Enclosed Wifi IEEE 802 11 Network Enclosed I O Device One Discrete Output 20 Amp Relay SPDT Override One Discrete Input Dry Contact Class 2 24 Vac dc DIP Switch CLOSED 12 Status O Ad Hoc Status O Infrastructure Status O Device Status O Pink LED Green LED O Yellow LED N a Relay State Green LED AUTO 4 x Override ON V 4 Override OFF Relay Status O 24 Vac dc 2 Red LED Relay Contacts ism RESET to Factory O Shown Made in USA Defaults Pushbutton N C N O COM With Meets Activate with Cover af APRA 006 insulated tool Specifications Code Version 4 0 1 Relays amp Contact Type Expected Relay Life Operating Temperature Operate Time Pink LED One 1 SPDT Continuous Duty Coil 10 million cycles minimum mechanical 30 to 140 F 18ms Digital Input Status
7. 8 100 10 config htm loc user defined text 16 characters max Follow standard URL encoding Avoid non alphanumeric characters as they may be interpreted as Escape Codes and may cause errors To reset device http 192 168 100 10 reset htm To configure Universal Inputs 1 and 2 The universal inputs can be set up via 4 different methods manually through the web page via a PC Smart Phone sending HTTP GET commands to the device over the network from a controller or thru a web browser or by clicking on predefined setup links similar to bookmarks in a web browser or clickable links within a Word document There are 5 different modes that the universal inputs support 1 9105 0 5Vdc input mode with OPEN or CLOSED feedback If input is less than or equal to 0 5 Volts the digital input status will show OPEN When the input volt age is greater than or equal to 4 5 volts the digital input status will show CLOSED When the input voltage is in between the digital input status will show NULL 2 010 0 10Vdc input mode 3 420 4 20mA input mode with additional hardware jumper installed 4 therf Type 2 thermistor input mode with results in Fahrenheit 5 therc Type 2 thermistor input mode with results in Celsius The 0 5Vdc 0 10Vdc and the 4 20mA inputs all support using minimum and maximum scaling floating point values and provide a measurement units entry field i e If input is set to 0 5Vdc input with a minimum scale v
8. B Devices Inc RIBTW2401B WIUI N4 BULLETIN CONT Web Page To enter the Wi Fi RIB into Infrastructure Mode or to return to Ad Hoc Mode Click Wifi link on top of page Note 1 If a mistake is made setting up the Wi Fi RIB it may be necessary to manually return to Ad Hoc Mode Pressing the RESET pushbutton about 5 seconds on the Wi Fi RIB will return it to factory default settings including returning it to Ad Hoc Mode Note 2 You may scan for the desired router if in range or enter the name and security type of the router the Wi Fi RIB will retain the router information if power is removed from the Wi Fi RIB and will find the router once power is restored to the Wi Fi RIB if the router is in range 1 To scan for routers in range click Scan For Wireless Networks to find search list of Wifi routers of desired infrastructure network and select router 2 To enter the name and security type of the router click Other Network and enter Mode Network Name Password Type WEP WPA then press Join The green Ad Hoc Status LED will extinguish and the yellow Infrastructure Status LED will begin flashing at a rate of once per second until the Wi Fi RIB establishes connection to router and then stay on once completely connected see Device LEDs for other LED indications The Wi Fi RIB will be entered into the infrastructure network on the router You must now go back view wireless networks on
9. IB Anywhere in a Building Automation System or Industrial Control System where cost reduction and ease of installation is critical a Wi Fi RIB can be your answer Whether retrofitting or with new installation within educational medical and commercial industrial facilities a wireless Wi Fi RIB can do the job for you RIB a y Wi Fi RIB RIBTW2401B WIUI N4 From the design engineering aspect to the installation of the Wi Fi RIB lower cost and flexibility enables our wireless device to be the solution If you want to wirelessly monitor temperature humidity or static pressure for example our Wi Fi RIB is the solution If you want the ability to turn Variable Frequency Drives VFD on off again our Wi Fi RIB is the solution Even with external devices such as rooftop AHU units where energy and installation savings opportunities are present let Functional Devices be your solution Is a Wi Fi RIB secure The Wi Fi RIB offers an authentication security option with a required username and password Authentication security can be bypassed if Wi Fi Protected Access Protocol WPA2 is the only required security Additional network security options are available 1 Access to a private network can be restricted to unauthorized Internet users with the creation of a network firewall Contact your IT Systems Administrator for more details 2 Security settings for a Router and or Access Point can
10. Internet Explorer type in the default factory address of 192 168 100 10 and press enter Note If a password has been entered on Setup page for Authentication Security authentication may be required after pressing enter Main Page Click Main link at top of page to return to this page In the web browser window you should see the Wi Fi RIB main web page You will be able to control the relay and read status To change the state of the relay click the on or off button and click Set Relay At the bottom of the page you can see status of relay last command universal inputs 1 and 2 and their associated digital inputs DI 1 and DI 2 webpage allows one or both universal inputs to be configured as digital inputs and are usable as such in ad ditional to the general purpose digital input Setup Page Network and operational settings Click Setup link at top of page Note Settings can be viewed on Main Page status or in the xml status page 1 Change the RIB default IP address port number subnet mask or gateway if desired click save after each setting Note The Wi Fi RIB ships from the factory with a default IP address of 192 168 100 10 default gateway of 192 168 100 1 and default subnet mask of 255 255 255 224 and hasaunique MAC address for use on the internet or on an internal intranet or network If at anytime an incorrect address is used or address is forgotten the Wi Fi RIB may be returned to facto
11. LASTSTATE Other binding state BOUND User defined label User defined label Factory firmware version lt ssid gt WifiRIBsBldg2 lt ssid gt SSID name of router connected to lt response gt This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help
12. Note Ad Hoc Mode must be used for set up and may be used for permanent use 1 Make sure laptop IP settings are in DHCP mode 2 Apply power to the Wi Fi RIB 24Vac or 24Vdc all settings will be maintained when power is removed The green Device Status LED will flash at a rate of once per second and the green Ad Hoc Status LED will stay lit while in Ad Hoc Mode yellow Infrastructure Status LED will remain off while in Ad Hoc Mode see Device LEDs for other LED indications 3 View Wi Fi connections on the computer Look for the network called RIBTW24B WI N4 and connect This establishes a connection between the Wi Fi RIB and the computer in an Ad Hoc network 4 In any Internet web browser type in the default factory address of 192 168 100 10 and press enter Page Click Main link at top of page to return to this page In the web browser window you should see the Wi Fi RIB main web page You will be able to control the relay and read status To change the state of the relay click the on or off button and click Set Relay At the bottom of the page you can see status of relay and last command Setup Page Network and operational settings Click Setup link at top of page Note Settings can be viewed on Setup Page status or in the xml status page 1 Change the RIB default IP address port number subnet mask or gateway if desired click save after all changes are made After making any changes to t
13. alue of 0 00 and a maximum scale value of 100 with units set to Volts A 2 5 Volt input would produce a 50 result If scales were changed to min of 0 and a max of 5 then a 2 5Vdc input would produce a 2 5Vdc one for one result Example usage for setup for UI1 and UI2 via controller or web browser http 192 168 100 10 config htm uil di05 amp min1 0 00 amp max1 100 00 amp unt1 Vdc http 192 168 100 10 config htm ui1 therf http 192 168 100 10 config htm ui2 010 amp min2 0 00 amp max2 10 00 amp unt2 Vdc http 192 168 100 10 config htm ui2 therc 1 Universal Input Mode 1 Set to any of 5 listed modes above ui2 Universal Input Mode 2 Set to any of 5 listed modes above min1 minimum scale for use with in floating point format max1 maximum scale for use with 011 in floating point format min2 minimum scale for use with UI2 in floating point format max2 maximum scale for use with UI2 in floating point format unt1 Units used for up to 9 characters of text unt2 Units used for 012 up to 9 characters of text 17 Devices Inc RIBTW2401B WIUI N4 BULLETIN CONT To read status information http 192 168 100 10 status xml Response will be in the following format lt xml version 1 0 encoding utf 8 gt lt response gt relayState OVERRIDDEN OFF lt relayState gt lastCommand OFF lastCommand digtalInputState CLOSED digtalInputState uilState 0 5V uilSt
14. ate lt uil Value gt 49 85 Percent lt uil Value lt dil Value gt Closed lt dil Value gt lt ui2State gt 0 5V lt ui2State gt lt ui2Value gt 49 85 Percent lt ui2 Value gt di2Value Closed di2Value powerOnState OFF powerOnState lt bindingState gt UNBOUND lt bindingState gt deviceHostName Device Name lt deviceHostName gt deviceLocation Device Location lt deviceLocation gt deviceVersion v4 0 7 1 0 WIUI lt deviceVersion gt bss lt valid gt 0 lt valid gt lt name gt 0 lt name gt lt privacy gt 0 lt privacy gt lt wlan gt 0 lt wlan gt lt strength gt 0 lt strength gt lt bss gt lt gt 0 lt gt lt ver gt 4615 lt ver gt lt count gt 0 lt count gt RIB Wi Fi Transmitter Module Information Other relay states OFE OVERRIDDEN ON ON BOUND ON BOUND OFF Other network command ON Other digital in state OPEN Other Universal Input 1 settings 0 10V 4 20mA T2 Thermistor E T2 Thermistor C Universal Input 1 analog value scaled by customer followed by label entered by customer Universal Input 1 DI status analog range 0 5V must be selected and scale set to 0 5 Other Universal Input 2 settings 0 10V 4 20mA T2 Thermistor E T2 Thermistor C Universal Input 2 analog value scaled by customer followed by label entered by customer Universal Input 2 DI status analog range 0 5V must be selected and scale set to 0 5 Other default power on states ON
15. be defined with a Service Set Identifier SSID A required password can be used to gain access Contact your IT Systems Administrator for more details 01 Functional Devices Inc RIBTW24B WI N4 On Off control throughout networ Parking Lot Lights Air Handling Units Unit Ventilators RIBTW2401B WIUI N4 On Off Monitor Control with results throughout network Temperature Humidity Current Flow Pressure Level Proximity 02 Devices Inc RIBTW24B WI N4 12 OPEN N Relay State IEEEE 802 11 b g n compatible G lt 54 Mbps Data Rate SS S Static Address a 4 99 SP DIP Switch 0000 S CLOSED s5558 Local Relay 5 5 d g Overide 2528 Switch 23a aea 2 x aea c 0 O Red LED Green LED gt Override ON Relay Contacts O Yellow LED Relay Contacts RESET to Factory Defaults Pushbutton ME WE 1 PPOR ney Activate with insulated tool Reset Button Factory settings RIBTW2401B WIUI N4 Local Relay Universal Inputs 2 Overide Switch Reset Button Universal Input 1 Universal Input 2 Eis d 5V 5V 02 COM Activate with insulated tool 4 20mA ONLY UD when used 420 420 E FE E amp amp requires jumper to be installed Di contact i B input P 8 S d ul lt a
16. ce over Wifi network commands the DIP switches take precedence over both the Digital Input if binding activated and the Wifi network commands 16 Functional 2 Devices Inc RIBTW2401B WIUI N4 BULLETIN CONT Wi Fi RIB Control and Status by HTTP Commands and XML HTTP Get commands to control relay and get status bypassing Wi Fi RIB webpage Status returned in XML format Note If password has been entered for Authentication Security on Setup page URL usage for all URLs below must include admin password as follows Before no admin password used After with admin password http 192 168 100 10 ribon htm http admin password 192 168 100 10 ribon htm To change password from controller http admin oldpass 192 168 100 10 config htm Pass newpass To turn relay on and off http 192 168 100 10 ribon htm i i m Example commands use factory default IP address To configure relay power up state 192 168 100 10 If you have changed the IP address http 192 168 100 10 config htm pwr on of the Wi Fi then use your address in the commands http 192 168 100 10 config htm pwr oft http 192 168 100 10 config htm pwr last To configure whether relay is bound or unbound to digital input http 192 168 100 10 config htm dry on http 192 168 100 10 config htm dry off To set name and location http 192 168 100 10 config htm host user defined text 16 characters max http 192 16
17. connect the laptop or controller to the same router network to see and control the Wi Fi RIB 12 RIB Functional _ Devices Inc RIBTW24B WI N4 BULLETIN CONT To read status information http 192 168 100 10 status xml Response will be in the following format lt xml version 1 0 encoding utf 8 gt lt response gt lt relayState gt OVERRIDDEN OFF lt relayState gt Other relay states OFE OVERRIDDEN ON ON BOUND ON BOUND OFF lastCommand OFF lastCommand Other network command ON digtalInputState CLOSED digtalInputState Other digital in state OPEN powerOnState OFF powerOnState Other default power on states ON LASTSTATE lt bindingState gt UNBOUND lt bindingState gt Other binding state BOUND lt deviceHostName gt Device Name lt deviceHostName gt User defined label lt deviceLocation gt Device Location lt deviceLocation gt User defined label lt deviceVersion gt v3 3 9 WI deviceVersion Factory firmware version lt bss gt lt valid gt 0 lt valid gt lt name gt 0 lt name gt lt privacy gt 0 lt privacy gt lt wlan gt 0 lt wlan gt RIB Wi Fi Transmitter lt strength gt 0 lt strength gt Module Information lt bss gt lt gt 0 lt gt lt ver gt 4615 lt ver gt lt count gt 0 lt count gt lt ssid gt WifiRIBsBldg2 lt ssid gt 5510 name of router RIB is connected to lt response gt This equipment has been tested and found t
18. hese settings you will need to reconnect to the RIB at its new address Note The Wi Fi RIB ships from the factory with a default IP address of 192 168 100 10 default gateway of 192 168 100 1 and default subnet mask of 255 255 255 224 and has a unique MAC address for use on the internet or on an internal intranet or network If at anytime an incorrect address is used or address is forgotten the Wi Fi RIB may be returned to factory defaults by pressing the RESET pushbutton on the Wi Fi RIB until the Device Status LED flashes rapidly approx 5 seconds 2 Set Device Name and click save Set Device Location and click save Up to 16 characters 3 Default Relay Setting determines the state to which the relay will default upon return from deliberate power cycle or due to power loss Make selection for relay to come on stay off or return to last commanded state After power up the relay will follow commanded states if communications are restored unless bound to Digital Input 4 General Purpose Digital Input Relay Binding allows the relay to be controlled from the Dry Contact GP Digital Input if desired If bound the relay will follow the state of the Digital Input typical application motion detector closes dry contact input relay turns on light If unbound the Digital Input may be used as a general purpose status input or otherwise independent of relay Web Page To enter the Wi Fi RIB into Infrastructure Mode or to re
19. o comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 13 _ Functional Devices Inc RIBTW2401B WIUI N4 BULLETIN RIBTW2401B WIUI N4 Wifi IEEE 802 11 b g Network Enclosed Device One Discrete Output 20 Amp Relay SPDT Override One Discrete Input Dry Contact Class 2 Two Universal Inputs 24 Vac dc 120 Vac Power Universal Input 1 5V UN COM Universal Input 2 5V 02 COM RESET to Factory Defaults Pushbutton Activate
20. ry defaults by pressing the RESET pushbutton on the Wi Fi RIB until the Device Status LED flashes rapidly approx 5 seconds 2 Choose to enable Username Password Authentication security or not To enable security enter up to eight alpha numerical characters in the Password field case sensitive Username defaults to admin and cannot be changed 3 Set Device Name and click save Set Device Location and click save Up to 16 characters 4 Default Relay Setting determines the state to which the relay will default upon return from deliberate power cycle or due to power loss Make selection for relay to come on stay off or return to last commanded state After power up the relay will follow commanded states if communications are restored unless bound to digital input 5 General Purpose Digital Input Relay Binding allows the relay to be controlled from the Dry Contact GP Digital Input if desired If bound the relay will follow the state of the Digital Input typical application motion detector closes dry contact input relay turns on light If unbound the Digital Input may be used as a general purpose status input or otherwise independent of relay 6 Universal Input 1 Setup and Universal Input 2 Setup are used to setup input to analog 0 5 V 0 10 V or 4 20 mA or Thermistor input in Degrees F or C Analog inputs use min and max of scale and units set by user Min and max are not used when T2 Thermistor selected 15 RI
21. security Note There will be no security if password field is left blank A password may be entered that will secure the webpage as well as Controller Commands Eight alpha numerical characters case sensitive 3 4 20 mA when used requires jumper to be installed on UI set for 4 20 mA input Jumper MUST be removed when UI input used as anything other than 4 20 mA 14 Devices Inc RIBTW2401B WIUI N4 BULLETIN CONT Wi Fi RIB Getting Started Note Ad Hoc Mode must be used for set up and may be used for permanent use 1 Make note of current computer IP settings and restore settings when finished If you are unsure of settings contact your network administrator 2 Make sure computer is set to DHCP mode then connect to Wi Fi RIB as follows 3 Connect and apply power to the Wi Fi RIB 24Vac or 24Vdc recommended for setup to avoid Line Voltage wiring all settings will be maintained when power is removed The green Device Status LED will flash at a rate of once per second and the green Ad Hoc Status LED will stay lit while in Ad Hoc Mode yellow Infrastructure Status LED will remain off while in Ad Hoc Mode see Device LEDs for other LED indications 4 View Wi Fi connections on the computer Look for the network called RIBTW2401B WIUI and connect This establishes a connection between the Wi Fi RIB and the computer in an Ad Hoc network 5 In any Internet web browser such as Safari Firefox or
22. turn to Ad Hoc Mode Click Wifi link on top of page Note 1 If a mistake is made setting up the Wi Fi RIB it may be necessary to manually return to Ad Hoc Mode Pressing the RESET pushbutton about 5 seconds on the Wi Fi RIB will return it to factory default settings including returning it to Ad Hoc Mode Note 2 You may scan for the desired router if in range or enter the name and security type of the router the Wi Fi RIB will retain the router information if power is removed from the Wi Fi RIB and will find the router once power is restored to the Wi Fi RIB if the router is in range 1 To scan for routers in range click Scan For Wireless Networks to find search list of Wifi routers of desired infrastructure network and select router 2 To enter the name and security type of the router click Other Network and enter Mode Network Name Password Type WEP WPA or no password then press Join The green Ad Hoc Status LED will extinguish and the yellow Infrastructure Status LED will begin flashing at a rate of once per second until the Wi Fi RIB establishes connection to router and then stay on see Device LEDs for other LED indications The Wi Fi RIB will be entered into the infrastructure network on the router You must now go back view wireless networks on the computer to connect to the same network to find the Wi Fi RIB Once the Wi Fi RIB is connected to a router in infrastructure mode you must
23. with insulated tool Network Compatible Relay Ul Um O O O O O 420 420 2 a a a Purpose 5 g DI Dry Contact a 5 9 Input 4 W um t COM F amp 24V Optional a 5 24Vac 5 zz Power Input 24Vdc Relay Contacts gt Term A Not used Vac 120 Vac Optional 9 E S Term Neut Power input S S S Specifications Relays amp Contact Type One 1 SPDT Continuous Duty Coil Contact Ratings Expected Relay Life Operating Temperature Operate Time Pink LED Green LED Yellow LED Green LED Red LED Dimensions Wires Approvals Housing Rating Gold Flash Relay Override Switch Wifi Security 10 million cycles minimum mechanical 30 to 140 F 18ms Digital Input Status Wifi Ad Hoc Status Wifi Infrastructure Status Device Status Relay Status 4 28 x 7 00 x 2 00 with 75 NPT Nipple 16 600V Rated UL Listed UL916 C UL FCC CE RoHS Wifi Certified ASD Device UL Accepted for Use in Plenum NEMA 4X No DIP Switch Control IEEE 802 11 b g n Compatible G 54 Mbps Data Rate 95 dBm Sensitivity 16 dBm Output Power WPA PSK or WPA 2 PSK Available Supports PING and ARP DSSS Modulation Customer can choose to have Webpage and Controller Commands authentication se cured with Username and Password 20 Amp Resistive 277 Vac 5 Amp Resistive 480 Vac 20 Amp Ballast