Home

RMS5733 LCD MONITOR - Professional Video Store

image

Contents

1. make DEFAULT at SET and you can reset the following parameters of BRIGHTNESS CONTRAST SATURATION SHARPNESS HUE to zero F1 F2 F3 Set steps press MENU combined with buttons of A Cup or V down you can find CONFIG in the sub MENU also combined with buttons of A Cup or V down and you will find Fl F2 F3 F1 F2 F3 can be used as quick button and each has the same eight options to define When you choose one option for example if you have already set F1 at H V DELAY you can press F1 directly to realize each function of H V DELAY and need not set in the MENU Of course you can set Fl at other option accordingly The function of Fl F2 and F3 can be set in the MENU The options are the following H V DELAY VOLUME DOWN VOLUME UP OSD CONTROL COLOR BAR AUDIO MON AREA MARKER and SAFE MARKER And each option will be specified as follows H V DELAY H V V H OFF Function horizontal blank vertical blank horizontal vertical blank or no blank VOLUME DOWN Volume become down gradually VOLUME UP Volume become up gradually OSD CONTROL Display TC code UMD code and audio meter or not Page 6 of 7 User Manual for RMS8424 HSC COLOR BAR Display COLOR BAR or not AUDIO MON Monitor one audio source of four audio sources AREA MARKER Images show with one scale of 2 35 1 1 85 1 15 9 14 9 13 9 4 3 or OFF SAFE MARKER Display CENTER mark 90 mark and 80 mark or not Note Please set F1 F2 and F3 to m
2. the front of the unit Page 1 of 7 User Manual for RMS8424 HSC Front Panel RMS8424 SEE BLUE LL dij ASPECT BAN o n ur umu V ENTEN H 2 Gl d G5 A A fo 1 Power On Off Switch When indicator above the power switch in green it indicates that power is on 2 ASPECT button lamp Change the aspect ratio of the picture between 4 3 and 16 9 3 SCAN 4 5 6 F1 F2 F3 The function of F1 F2 and F3 serve as quick buttons the function can be assigned in the MENU 7 MENU Displays the main menu Menu Operations on page 5 8 9 Two functions gt Press MENU to choose the function you need gt When the MENU Is not in use the button of 8 9 can achieve the following functions 8 Blue Only 9 Audio Selection and MUTE button Audio Selection press the button to select the monitoring audio of the corresponding monitor Mutes press the button again to mute the sound To cancel the function press the button again Note two monitors share one earphone jack the indicator in lighting shows its audio is being monitored in flickering shows its audio is being muted of corresponding monitor Page 2 of 7 User Manual for RMS8424 HSC 10 Enter gt Enter the menu items when menu is displayed gt Enter instant parameters adjustment when menu isn t displayed The following parameters can be regulated AUDIO MON VOLUME BRIGHTNESS CONTRAST SATURATION SHARPNESS HUE 11 EA
3. OFF STATUS NDICATION ON SCREEN DISPLAY am an m of up to mM including alphbet digits mr some symbols is all owned CONF F1 F2 ES HN DELAY VOLUME DOWN VOLUME UP OSD CONTROL COLOR BAR AUDIO MON AREA MARKER SAFE MARKER OSD CONTROL ON OFF COLOR BAR DISABLE Page 5 of 7 User Manual for RMS8424 HSC Quick Button Specification y 2 ENTER When MENU is not used you can press ENTER to regulate the following parameters AUDIO MON VOLUME BRIGHTNESS CONTRAST SATURATION SHARPNESS HUE Press ENTER seven times parameters will revolve You can get the exact value combined with buttons of A Cup or V down AUDIO MON Have four options of METI MET2 MET3 and MET4 When MET is selected the first audio source will be monitored Likewise if you select other MET the corresponding audio source will be monitored VOLUME 772 Used to regulate the volume Range 30 0dB the maximum OdB BRIGHTNESS Z amp f Used to regulate the brightness range 116 139 the typical 0 CONTRAST LE E Used to regulate the contrast of image range 128 127 the typical 0 SATURATION FII EE Used to regulate the saturation of image range 128 127 the typical 0 SHARPNESS JU w fit i BE Used to regulate the sharpness of image range 0 15 the typical 0 HUE f amp if Used to regulate the hue of image range 32 31 the typical 0 Note regulate the option DEFAULT of sub MENU CONFIG in the MENU
4. RMS8424 LCD MONITOR USER MANUAL User Manual for RMS8424 HSC RMS8424 LCD Monitor USER MANUAL Product Overview The 3U rack mounted RMS8424 HSC represents new trend in LCD monitor for broadcast and professional video applications It has 800X600 high resolution anti glare TFT screens with full digital signal processing HD SDI SD SDI and analog composite video standards are accepted of this model All video formats are scaled to fit on screen in the highest quality using full digital processing precision scaling and Gamma correction to produce the best images available Operational Setup 1 Unpack the RMS8424 and accompanying power supply Physically inspect for any damage that may have occurred during shipping Should there be any damage immediately contact OSEE DIGITAL TECHNOLOGY LTD at 86 010 62968823 2 After inspection install in your desired location of a standard EIA 19 inch equipment rack Adequate ventilation is required when installed to prevent possible damage to the RMS8424 internal components 3 Connect required cables for signal input and output Please note that power must be applied to the RMS8424 for all outputs to be activated All BNC connectors should be rated for 150 4 Plug the power supply into the A C source 5 Attach power connection from power supply to the back of the unit 6 Fasten the power protect accessory 7 Turn on each screen of the RMS8424 by depressing the power switch located on
5. RPHONE JACK Rear Panel Connectors HD SDI SDI inputs comply to SMPTE259M SMPTE292M ITU R BT601 Composite Video Inputs comply to SMPTE 170M All Outputs Require Power to be applied for activation only SDI signal can be output Tally lamps active when connected to ground Active Output2 Active Outputl Re Clocked And Re Shaped Re Clocked 12VDC from And Re Shaped power Monitor Input2 Monitor Inoutl HD SDI SDI HD SDI SDI TALLY IN Analog Analog DB 9 Male Composite Composite Table 1 Pins of Tally IN Tally IN DB 9 Male Page 3 of 7 User Manual for RMS8424 HSC Instructions on Monitor Display Status Auto sensing on input signal 4 channel audio meter display for S D SDI and 8 channel audio meter display for HD SDI Specifications Number of Screens Display Viewing Area Viewing Angles Screen Colors Bit Depth Resolution Dots Dot Pitch Contrast Ratio Pixel Response Dimensions Power Consumption Operating Temperature System Inputs Active Outputs 1030150 a gt 2 29805145 21 24 8 4 diagonal 6 43 H x 4 09 V 170 4mm x 127 8mm 160 H x125 V 800H x 600V 0 213 x 0 213mm 320 1 262K 18 Bit 19 x 6 97 x 1 69 482 6 x 177 x 43 mm Note Specifications are subject to change without notice Page 4 of 7 User Manual for RMS8424 HSC RMS8424 Menu Description VIDEO MET 3 TYPE METATYPE MARKER AREA 2 35 1 1 85 1 15 9 14 9 13 9 4 3
6. eet your actual requirement For example if you often use H V DELAY you d better set F1 F2 or F3 at H V DELAY MENU When you want to change the value of a parameter you may use MENU and you can follow four steps gt Step 1 Press MENU and you can enter the main MENU gt Step 2 Press buttons of A Cup or V down to choose a option and when you get one press ENTER and you can enter the sub MENU gt Step 3 Press buttons of Cup or V down to choose a parameter then press ENTER and press or V to acquire the exact value gt Step 4 Press MENU to return You can follow the same step to set other parameters In a word when you set a parameter the buttons of ENTER MENU A and V will be used frequently The function of each button is listed below ENTER Enter the sub menu MENU Return to the super menu Cup or V down Switch the options in the same menu or set the value of a parameter Page 7 of 7