Home
User`s Manual For MS-E8221
Contents
1. 1360nm Tansmission distance According to the different optical module it could be 10km or 20km WWW MISENSECOM COM Page 9 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID Dispatch optical power Refer to SFP optical module specification Receive sensibility Saturation optical power Refer to SFP optical module specification Refer to SFP optical module specification Table 3 EPON Optical Port Parameters 3 2 Up link data port Number of ports 2 Form SFP power supply Voltage 3 3V Interior signal interface SGMII Supporting module SFP optical module or SFP electrical module Working speed Optical module 1000M full duplex Electrical module 1000M full duplex 3 3 Console interface Interface type RJ45 Switch line RJ45 DB9 use the special connection cable which is configured by the factory signal level standard is RS232 WWW MISENSECOM COM Page 10 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID 3 4 Out band network management interface Standard IEEE802 3 Transmission speed 10M 100M full or half duplex Cable RJ45 joint CATS non shield crossing line use crossing line to connect PC use parallel line to connect HUB Tansmission distance 100M Number of port 1 3 5 Management configuration You should conduct the local management through CONSOLE port or connect remote management through out
2. statistical information Support hot plug by the board Offer 2G uplink The uplink is SFP and could be configured as electrical port or optical port If configured as electrical port it should work as the pattern of 1000M Support the VLAN division on the basis of port Support 4096 entries of VLAN The capacity of MAC address is 8K Uplink support port trunk port monitoring and mirroring gt Offers 2 control interface local and network gt Support 3 types of management CLI TELNET and SNMP WWW MISENSECOM COM Page 3 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LTD gt The net Work control supports in band and out band Support read of SFP mode 1 2 2 Functional features of other ports The sketch map of front panel is as follows Chart 1 Product appearance diagram Descriptions of the interface From left toright the discriptions are as follows gt The RS485 interface use to transfer serial informations from ONU RST button press this button to trigger the board restoration Consloe port local management interface RS232 connector type RJ45 Manage port out band management interface 10M 100M full or duplex ethernet interface connect type RJ45 GE1 amp GE2 port uplink SFP mode it can configured as WWW MISENSECOM COM Page 4 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID fiber or electical mode gt PONI amp PON2 port downlink SFP mo
3. AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LTD User s Manual For MS E8221 Version V1 0 WWW MISENSECOM COM AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LTD CONTENT I 2PRODUCT INTRODUCTION EE 1 1 1 Product summarise ievmeeeneveenteeenneeenneee nene enneeennneenneo enne enneee anne enneeeanaeenneee anne enneee ena 1 1 2 Functional E EE 1 1 2 1 EPON port Functional features 1 1 2 2 Functional features of other ports werenerevereneeenneeeeeeneeenneeneennnenneenneenneeee 4 1 3 Size and weight 6 2 EQUIPMENT INSTALLATIONS nn enneaeeeneoe ee nnnaneeee onne ennnnennneee een enneeenee nee 6 2 1 Installation enviroment criscini enii e aka a iaae ie 6 2 2 EPON Port connection weemeeeenenenneeenteeenneeennneonneeonnaeenneennneeenneeennaeenneeenneeenneeen 6 2 3 Uplink SFP installation metemeeneeveneneneeananneenenteoneonnenesenenneanenneenaeneeneeenenneenenne i 7 2 4 Equipment Cle CHALY ss svsssceevcavcvsiveveeivcesveasaeveatesucvosns stew seuedeessauseeavegevounvarucctsteducesatosmueete sey aneed amp 2 5 POWER EE EE 8 2 6 Eguipment eleGtrifV siwidusssssiteni hvasahihvdeiaev ei aE E E reS vas E E ER a amp 3 TECHNOLOGY e EL LEE 9 3 1 EPON optical port specUieogttion 9 3 2 Up linkda P r soso zest iheciatete gist t nks ie tT ahasdecioee ein ER a aes 10 3 3 Console interface sisse E ee REENEN BEE NEE EEN gubipasrdnteee
4. band network management port or in band management Use EMS network management network to do the network management As to the installation and use methods of EMS please refer to EMS User s Manual This manual wouldn t introduce more 3 6 Common fault analysis If you meet the following problems when you install or use the equipment please refer to below recommendations to solve the problem any further problems please contect the seller WWW MISENSECOM COM Page 11 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID Common fault Fault resolution recommendation CONSOLE Connection 18 not succesful Check whether the connection cable is proper or not if the parameter of band rate is set correctly please use the special connection cable which is offered by the factory The work bandrate of CONSOLE port is 115200 When up link connect to SFP electrical module it only works in 1000M Could not be connected to the out band network Management interface Could not be connected when use SFP optical module Check the connections on whether to support Gigabit only each other to support gigabit mode to be able to connect Check the cable use the crossing cable when connected to PC use parallel to connected to HUB Check if the parameter of optical power parameter is matched the requests of module specification if input optical power is more than module sensibility if it is less
5. de Discriptions of indicator lights from the left to right and up to down Indicator light color Definition Off power is abnomal PWR Green On power is nomal Off abnormal system operation SYS Green On normal system operation Flash there are data passing from uplink port ACTI Green Off there are no data passing from GE1 uplink port LINKI Green On uplink port is connect Off uplink port isn t connect Flash there are data passing from uplink port ACT2 Green Off there are no data passing from GE2 uplink port On uplink port is connect LINK2 Green Off uplink port isn t connect WWW MISENSECOM COM Page 5 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID On The first port connected to ONU PON1 LINKI Green Off The first port not connected to ONU On The second port connected to ONU PON1 LINK2 Green Off The second port not connected to ONU Table 1 the discription of indicator lights of panel 1 3 Size and weight Size 441mm 192mm 43mm Weight about 3kg 2 Equipment installations 2 1 Installation enviroment Installed in the center room on the rack 2 2 EPON Port connection First install the OLT SFP optical module and after installing the optical module insert SC PC fiber to SFP optical mode and the process is completed Note Keep the joint of fiber clean and please preserve the cap
6. laassioubedvoasebes 10 3 4 Out band network management nierltce nee Il 3 5 Management configuration venccesccssesssesinessiesssveosevonsevedtesveusstecscvesteessventesbevente EE E 11 3 6 Common fault analysis ENEE 11 APPENDIX A SECURITY EROMET VE 14 APPENDIX B TROUBLE HANDLING csccsecoscsacossonesvventsoesescosesvevnesocensesessncseessceteousoseusnevassneonscaeeseutesstents 14 APPENDIX C PRODUCT APPLICATION E 15 WWW MISENSECOM COM AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LTD 1 Product introduction 1 1 Product summarise MS E8221 is the Central Office mainfram box platform of GEPON series products which is researched and developed by our company it is Able to provide a variety of integrated services access such as broadband voice IPTV CATV It includes 2 independent fiber terminals OLT unit and 2 SFP GE uplink port 1 console port 1 Of band management port 1 RS485 port All the GEPON series products of our company are using passive optical network PON technologies which is better than traditional access products in cost performance maintenance expansibility and etc 1 2 Functional features 1 2 1 EPON port Functional features In GEPON system as the OLT unit PON port is responsible for the register of ONU transfers the Ethernet message received from network in the downlink to EPON optical signal and sent it to ONU by passive network In up link WWW MISENSECOM COM Page 1 16 AN misen
7. ne or parallel line to connect this port with PC or HUB NOTE The net cable or fiber is no available when the machine left the factory and the user needs to prepare it 2 5 Power requiement The power of the board is supplied by common AC power range is from AC100V AC250V Power consumption lt 15W 2 6 Equipment electrify The board supports hot plug and when the power is applied to it you could judge if it works normally or not through the indicator light conditions If the board has already connected with power or started to work the conditions of WWW MISENSECOM COM Page 8 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID indicator lights should be like the follows gt The power indicator light of the board is on gt At this time whether the EPON optical port is connected or not the link light should be off temporarily gt The board s initialization is completed no more than 20 Second and if the equipment has be connected with ONU equipment normally the LINK indicator light of EPON port of OLT should be on with means the ONU has connected to OLT normally 3 Technology specifications 3 1 EPON optical port specification Number of EPON optical port 2 Parameter of EPON optical port Parameter specification Module type 1000Base PX20 or 1000Base PX 10 Connection type SC PC Extents of optical wavlength Send 1480nm 1500nm Receive 1260nm
8. of flange for later use WWW MISENSECOM COM Page 6 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID 2 3 Uplink SFP installation The uplink port of the board is SFP interface the default option of the board before leaving the factory is no SFP module users could use proper SFP module according to his own situations SFP is standard parts when you install it directly inserting it to the SFP slot of the board The board could identify that the module which the user insert is optical module or electrical module In default conditions the board works in the normal exchange mode in that mode the 2 SFP interfaces of board are same and the uer could use any one of it But in isolation and converge mode user should choose the specific port In isolation mode the corresponding relations of up link ports and PON ports are as follows SFP uplink port PON port GEI PONI GE2 PON2 Table 2 the corresponding table of ports WWW MISENSECOM COM Page 7 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID 2 4 Equipment electrify SFP up link port on the basis of different type of modules use net cable or optical fiber to connect up link port and up layer network equipment such as switch router CONSOLE port use the DB9 RJ45 special connection cable which is the accessory of the equipment to connect CONSOLE port and DB9 interface of PC Manger port use crossing li
9. questions and problem please contact the person who sell this equipment to you WWW MISENSECOM COM Page 14 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID Trouble Trouble handling PWR light is off Check the whether the power connector is plugged in Check the swicth button is ON EPON optical port Check is the time of the power connection LINK light is off exceeds 20 seconds Check if it has been connected to ONU Check if the joint of fiber matched the optical module interface Check if the loss of optical fiber is exaggerated and if the sensibility of receive optical power is less than that of the optical receive The rate of data Check if the touchment of the optical joint is packet loss is too OK high Table 5 Touble handling of OLT equipment Appendix C Product application WWW MISENSECOM COM Page 15 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LTD Passive optical network GEPON Lengt Optical splider Chart 2 Product netting application chart WWW MISENSECOM COM Page 16 16
10. se AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID it receives EPON optical signal sent by ONU and transfer it to ethernet message then send to swich core eguipment It includes 2 PON port of 1 25G usually each PON port can access 32 pieces of ONU eguipment in the transmission distance of 20kms The equipment is composed by high integrated OLT chips and independent control modules offering reliable assurance for users in functions and performences The functional features of this board are summerized as follows gt gt Support ONUs communicate under the same PON port Support 802 3 MPCP protocal Support 802 3 OAM and expand protocal slave port have abundent OAM function design offer long distance management through OLT gt Have double channal independent OLT Support long distance update for software gt High integration level and integration management gt and have the function of double layer exchange Support data encrypt service in downlink secure the data transition security for users Support ONU authentication avert illegal ONU WWW MISENSECOM COM Page 2 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID Y Y VV WW WW V Y V V VV WV accesss to network Support DBA dynamic bandwidth allocation Support IGMP Proxy Support ACL functions Support QOS functions Support 4K MAC address with single channal OLT Support VLAN divided by LLID Offer abundant
11. than the optical module saturation In addition it is possible that the SFP module has been damaged so please WWW MISENSECOM COM Page 12 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID ensure the SFP module could work normally Abserve the problem still exist after replace the SFP module if Still could not solve the problem please seek our technology supporter Table 4 Common fault and resolution recommendation WWW MISENSECOM COM Page 13 16 AN misense AN SHENZHEN MISENSE COMMUNICATION TECHNOLOGY CO LID Appendix A Security Prompt gt Please read this manual carefully and install and use the eguipment according to the discription of this manual gt Please don t install this product in an enviroment which is too moist coagulate gt Please don t touch optical dispacher module with your hands in case the static damages the optical parts gt After the EPON OLT gets power do not looking at the optical outlet directly in case the eye get hurt gt Please don t curve optical fiber in random and the curving radius of the fiber should be not less than 38mm gt Before connecting with the fiber please don t pull out the hat of flange in case the end surface of fiber is polluted Appendix B Trouble handling If you meet the following problems when you installed and use the board please refer to the trouble handing recommendation below if you have more
Download Pdf Manuals
Related Search
Related Contents
Téléphone DECT GAP sans fil avec répondeur numérique VH-SB300BK Manual de usuario User Manual Máquinas de Gelo QuietQube Epson CX1500v Warranty Statement MASTER`S THESIS User Guide - Fujitsu manual server - Hawking Technology Manual do Usuário - Crowcon Detection Instruments Copyright © All rights reserved.