Home

E3NC-SH Laser Sensor Instruction Sheet 5339015-8B

image

Contents

1. to inflammable explosive gas To secure the safety of operation and maintenance do not install the product close to high voltage devices and power devices 2 Power Supply and Wiring Be sure to use a dedicated amplifier unit E3NC SAL L E3NC SAO Connecting the sensor to other amplifier unit may cause damage or fire e When short circuiting the cable be sure to connect wires correctly according to the specification Improper connection may cause damage or fire High Voltage lines and power lines must be wired separately from this product Wiring them together or placing them in the same duct may cause induction resulting in malfunction or damage e Always turn off the power of the unit before connecting or disconnecting cables Authentication label 3 Installation Use screws for mounting and be sure to tighten screws with a specified torque tightening torque M3 0 5N m 4 Other Rules Do not attempt to disassemble deform by pressure incinerate repair or modify this product e When disposing of the product treat as industrial waste If you notice an abnormal condition such as a strange odor extreme heating of the unit or smoke immediately stop using the product turn off the power and consult your dealer PRECAUTIONS FOR CORRECT USE Please observe the following precautions to prevent failure to operate malfunctions or undesirable effects on product performance 1 Do not install the product in loc
2. OMRON Smart Laser Head CMOS Model E3 NC SHC Series Thank you for selecting OMRON product This sheet primarily describes precautions required in installing and operating the product Before operating the product read the sheet thoroughly to acquire sufficient knowledge of the product For your convenience keep the sheet at your disposal Refer to the user s manual for details TRACEABILITY INFORMATION Representative in EU Omron Europe B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Manufacturer Omron Corporation Shiokoji Horikawa Shimogyo ku Kyoto 600 8530 JAPAN Ayabe Factory 3 2 Narutani Nakayama cho Ayabe shi Kyoto 623 0105 JAPAN The following notice applies only to products that carry the CE mark Notice This is a class A product In residential areas it may cause radio interference in which case the user may be required to take adequate measures to reduce interference OMRON Corporation 2012 All Rights Reserved PRECAUTIONS ON SAFETY Keys to Warning Symbols Indicates a potentially hazardous situation which if not avoided will N WARNING result in minor or moderate injury or may result in serious injury or death Additionally there may be significant property damage Explanation of signs Laser beam Cautions to indicate potential Laser beam hazard Resolution prohibition Indicates prohibition when there is a risk of minor injury from electrical shock or other source if th
3. S LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Phone 1 847 843 7900 Fax 1 847 843 7787 E ASIA PACIFIC OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Phone 65 6835 3011 Fax 65 6835 2711 E CHINA OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Phone 86 21 5037 2222 Fax 86 21 5037 2200 OMRON Corporation D OCT 2009 E3NC SH Series
4. atio objects smaller than the spot diameter objects with a large curvature excessively inclined objects etc Checking the package contents Sensor head x1 Manual this paper x1 W Shortening the connection cable for use ME Shortening the connection cable for use ti Operation lever White Push the operation lever at the operation slot with the slotted screwdriver and pull out the wire to adjust the cable length The tip of the screwdriver must be 2 mm or less The type of screwdriver whose tip width becomes broaden toward its root cannot be used E Procedure to connect the connector 1 According to STRIP GAUGE shown on the side of the product strip the coating of the shield for 20 mm or less strip the coating of the core wire for 7 to 8 mm and twist the wire for several times 2 Insert the wire all the way to the wire insertion slot Make sure that the wire coating is located inside the wire insertiong slot and the tip of the conductor passes through the connection part Connect wires as follows Terminal No 1 Shield Red White sides No 2 White No 3 Red No 4 Brown No 5 Blue No 6 Shield Brown Blue side 7to8mm _ Wire insertion port SUN Operation lever White Release port 3 Push the slotted screwdriver all the way to the releasing slot and pry the slotted screwdriver up and down lightly When you feel a click on the slotted screwdriver pry it to the reverse direction of the wir
5. ations subjected to the following conditions Surrounding air temperature outside the rating Rapid temperature fluctuations causing condensation Relative humidity outside the range of 35 to 85 Presence of corrosive or flammable gases Presence of dust salt or iron particles Direct vibration or shock Reflection of intense light such as other laser beams electric arc welding machines or ultra violet light Direct sunlight or near heaters Water oil or chemical fumes or spray or mist atmospheres Strong magnetic or electric field 2 Warming Up The circuitry is not stable immediately after turning the power ON and the values gradually change until the Sensor Head is completely warmed up 3 Maintenance and inspection Always turn off the power of the unit before connecting or disconnecting cables Do not use thinner alcohol benzene acetone or kerosene to clean the sensor If considerable foreign matter or dust collects on the front of sensor use a blower brush for camera lenses to blow off the foreign matter Avoid blowing it off with your breath For a small amount of foreign matter or dust gently wipe with a soft cloth Do not wipe hard If the surface is damaged false detection may result 4 Sensing Object For Reflective Type Sensor Head The product cannot accurately measure the following types of objects Transparent objects objects with an extremely low reflective sensor r
6. e insertion direction The operation lever will recover with a click sound 4 Check that the operation lever recovers and the wire coating enters into the wire insertion slot The shield wire cover must not be shorted circuited The wires are connected when you pull the wire and feel a resistance 1 Dimensions ST indicator Unit mm ST button 5 05 _ e SJ 7 Receiver center L is eal Measurable area E3NC SH100 L 35 to 100 mm A 15 92 5 67 E3NC SH250 L 35 to 250 mm A 15 92 2 27 White tube Vinyl insulated cable 4 dia 6 wire cross section of conductor 0 08 mm insulator diameter dia 0 38 mm Standard length 2m Minimum bending radius 12 mm ST Indicator Blue Turns ON when Smart Tuning is performed OUT Indicator Orange Turns ON when Output is ON ca Lo LH TT ST button Press both the ST button and S TUNE button at the same time to execut tuning STABILITY Indicator Green Turns ON when output is ON steadily 3 Installing Sensor Heads Fix the Reflective type sensor head with screws M3 tightening torque M3 0 3 N m Mounting dimensional drawing Unit mm Ny 27 0 05 25 4 0 05 CHECK 16008 When mounting a Sensor Head take care not to touch the emitter and receiver Adhesion of finger marks may hinder correct measure
7. e product is disassembled SAFETY PRECAUTIONS FOR USING LASER EQUIPMENT The E3NC LH use a laser as the light source Lasers are classified based on EN standard EN 60825 1 Alert Statements E3NC SHLJL Sensor Head Class 1 N WARNING Do not expose your eyes to the laser radiation either directly i e after reflection from a mirror or shiny surface Loss of sight may possibly occur in case of the exposure to laser high power density Do not disassemble the product Doing so may cause the laser beam to leak resulting in the danger of visual impairment The E3NC SH has the WARNING labe Description label regarding laser on the side of the Sensor Head as shown on the right figure This laser Product complies with 21CFR Class1 H AY and 1040 11 LASER PRODUCT When using devices in which E3NC SH is installed in the U S the devices are subjected to the U S FDA Food and Drug Administration laser regulations E3NC SH series is classified into Class1 by the standard of IEC EN60825 1 according to deviations of Laser Notice NO 50 of this standard and is scheduled to report to CDRH Center for Devices and Radiological Health Using in Europe The E3NC SH is categorized as a Class 1 device as stipulated in EN60825 1 PRECAUTIONS FOR SAFE USE Please observe the following precautions for safe use of the products 1 Installation Environment Do not use the product in environments where it can be exposed
8. m 35 to 250 mm 35 to 50 mm 1 5 mm 35 to 180 mm 9 mm 50 to 100mm 3 mm 180 to 250 mm 25 mm Approx 0 5 mm distance at 100 mm Approx 1 mm distance at 250 mm OUT indicator Orange STABILITY indicator Green ST indicator Blue llluminance on receiving optical llluminance on receiving optical side side 4 000 Ix max incandescent light 2 000 Ix max incandescent light Sunlight 8 000Ix max Sunlight 4 000Ix max Measurement range Standard measurement gap Spot size 3 Indicator Ambient illumination Ambient temperature Operating 10 to 55 C storage 25 to 70 C with no icing or condensation Operating and storage 35 to 85 with no condensation 20 MQ min 500 VDC Ambient humidity Insulation resistance Dielectric strength Vibration resistance 1000 VAC 50 60 Hz 1min 2 hours each in X Y and Z directions Approx 125 g approx 75 g Instructhin Sheet 1 The E3NC SH is classified into Class 1 by the standard of EN60825 1 according to deviations of Laser Notice No 50 of FDA standard and will be reported to CDRH Center for Devices and Radiological Health x2 Measured using Omron s reference sensing object white paper 3 Defined at the 1 e 13 5 of the central intensity at the measurement distance Measurement may be influenced if there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target objec
9. ments If you have touched them wipe them with a clean soft cloth Secure the connector to avoid vibration or shocks X Caution on Mounting Direction lt Detection Near the Wall Surface gt lt Cavity Detection gt ee p The Sensor is less The Sensor is easily influenced by Detection is not possible if influenced by ambient ambient lighting which may cause the emitter or receiver section lighting detection value variations is blocked lt Detection of Workpiece with Level Difference gt i pE Stable detection is possible Level difference may cause regardless of level difference an abnormal detection value Before performing tuning apply mat paint on the wall surface or turn ON the background suppression function to avoid laser light reflection 4 Mounting the sensor head 1 Open the protection cover 2 Insert the sensor head with the lock lever on its connector area facing upward all the way into the connector port To remove it press and hold the lock lever then pull the sensor head out Lock lever The connector cover of E3NC SH is white Connect the cable correctly Pannier couse whic E agLWN 5 Specifications Item Detection method Distance configuration model Model E3NC SH100 E3NC SH250 Light source wavelength 1 Visible light semiconductor laser 660nm 100 uW max JIS standard Class 1 IEC EN Class1 FDA Class1 35 to 100 m
10. t Also when detecting a workpiece that is smaller than the spot size a correct value may not be obtained Shock resistance Degree of protection Connection method Material Weight packed state main unit only Accessories Suitability for Use THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of the products in the customer s application or use of the product Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM See also Product catalog for Warranty and Limitation of Liability Mi EUROPE OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Phone 49 7032 811 0 Fax 49 7032 811 199 E NORTH AMERICA OMRON ELECTRONIC