1. ETH1000 MKII Gigabit Ethernet Media Converter User manual Rev 1 fil ETH1000 MKII Rev 1 Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 1 0 2011 11 29 AJM Changed wording in chapter 3 1 2011 06 30 GMW MS First version nevion com 2 ETH1000 MKII Rev 1 Contents Revision DIStOY ere ia aa aa i aai a ee 2 TIP TOGUCTOVELVIEW A E T E veh ET EE ET E EE 4 2 Specifications TTT 5 21 Optical GRASS ERMER aS 5 22 Eth mnet sd Na 5 2 3GeneAlu ar 5 3 Configuration EE EE EE NE NE 6 Sa DIP Controls A ra Aa as 6 3 2 Mulii on Gyda Controls pe sademadatnisetuneneulnunuednndsve hett 6 3 2 1 Block descriptions ale 7 4 Conector ne e Sc rr ete i te te tetra a a cn ne le ae rte 8 4 1 Mounting the connector module ae eee 8 4 2 Terminal format Support sss eee eee eee eee eee 9 YS INO GG Sta LUG ae 10 5 1 Front panel Status monitoring uv sse eee ee eee eee 10 5 2 GPI Alarm Module status outputs sees
2. eee 11 6 Laser safety DrecauiiOng eee eee 12 General environmental requirements for Nevion equipment 13 Product Warranty sese eee eee 14 Appendix A Materials declaration and recycling information cccccceeeeeeeeeeeeeees 15 A 1 Materials declaration 15 A 2 Recycling information sesyen ae aee EEE RE EEE A EAEE 15 nevion com 3 ETH1000 MKII Rev 1 1 Product overview The Flashlink ETH1000 MKII is a 10 100 1000Base T to 1000Base X media converter module The module converts a 10 100 1000Mbps Ethernet signal on copper to 1000Mbps optical on fibre suitable for medium haul applications The module has one electrical Ethernet port and one optical fibre transceiver port receiver fibre connector and transmit fibre connector The speed on the electrical connector is dependent of the DIP switch setting or GYDA control Speed will upon link connection automatically be set at the highest possible speed User can independently enable or disable 10Mbps 100Mbps or 1000Mbps The fibre link can be used in one or two fibre installations or occupy two wavelengths in a WDM or CWDM installation Optical transmitter Go Optical output 10 1 00 1 000Mbps Physical en din Optical reciver Optical gt input neni Microcontroller e a ESO Figure 1 Wwnevion N non APC l Pai Figure 2 nevion com 4 ETH1000 MKII 2 Specifications Rev 1 2 1 Optical Charact
3. 0Base T electrical connection DIP switch 4 enables disables auto negotiation on the optical connection 1000Base X When connecting ETH1000 MKII to ETH1000MC auto negotiation must be disabled Using two ETH1000 MKIls or ETH1000 MKII together with ETH1000 D these DIPs must be in the same position on both cards Also this dip must be on to be able to communicate with other vendors Ethernet switches Dip 5 6 and 7 are reserved Dip 8 sets if Multicon Gyda is able to configure or not When Multicon Gyda override is set the actual setting can be read by using the info command se Multicon Gyda user manual for details 3 2 Multicon Gyda control Latest configuration from Multicon Gyda is stored locally on the card This prevents configuration loss during power recycling The card supports Flashlink protocol v4 0 nevion com 6 ETH1000 MKII Rev 1 3 2 1 Block descriptions Supported block command 3 2 1 1 Laser lt identifier gt Isr lt status gt C lt wavelength gt nm lt power gt dBm on off ok fail lt block command gt lt operation gt lt operation gt on off 3 2 1 2 PIN lt identifier gt pin lt status gt cd ncd 3 2 1 3 Voltage lt identifier gt pwr lt status gt lt nominal voltage gt Vnom lt voltage gt 3 2 1 4 General output lt identifier gt gpi lt status gt out act inact thru id lt GPI ide
4. 50 nm Instruments exist to verify light output power Power meters IR cards etc Flashlink features All the laser module cards in the Flashlink product range are Class 1 laser products according to IEC 825 1 1993 and class according to 21 CFR 1040 10 when used in normal operation More details can be found in the user manual for the FR 2RU 10 2 frame Maximum output power 5 mW Operating wavelengths gt 1270 nm R lt 5m WAVELENGTH gt 1270nm CLASS II BLASER PRODUCT REF FDA CFR Ch 1 4 1 97 Ed 1040 10 1 Max power is for safety analysis only and does not represent device performance nevion com 12 ETH1000 MKII Rev 1 General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range lt 90 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing nevion com 13 ETH1000 MKII Rev 1 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 14 ETH1000 MKII Rev 1 Appendix A Materials declaration and recyc
5. ase X Input OPT TX Optical output 1000Base X Output 1000Base T Electrical input 10 100 1000Base T In output GPI ALARM Open Collector Wired alarms OC Output Alarms nevion com 9 ETH1000 MKII Rev 1 5 Module status The status of the module can be monitored in three ways 1 GYDA SC System Controller optional 2 GPI at the rear of the sub rack 3 LED s at the front of the sub rack Of these three the GPI and the LEDs are mounted on the module itself whereas the GYDA System Controller is a separate module giving detailed information on the card status The functions of the GPI and the LEDs are described in sections 5 2 and 5 1 GYDA SC is described in a separate user manual 5 1 Front panel Status monitoring The status of the module can be easily monitored visually by the LEDs at the front of the module The LEDs are visible through the front panel as shown in the figure below STATUS LOS ol LINK O ACT Figure 5 Front panel indicators for the ETH1000 MKII ETH1000 MKII has 4 LEDs each showing a status corresponding to the GPI pinning Diode State Red LED Green LED Orange LED No light Status Module is faulty Module is OK Laser off Module has no or module is Module power is power initializing OK LOS No optical signal Optical signal Module has no power LINK No 10 100 1000Base No link 10 100 1000Base T link T link ACT Ethernet traffic No Ethern
6. eristics Optical input Transmission circuit fibre Sensitivity Optical wavelength Detector damage threshold Max input power Connector Optical Output Transmission circuit fiber Light source Optical power Optical centre wavelength 2 2 Ethernet 9 125um Single Mode Better than 25dBm 1200nm 1610nm gt 1dBm 0dBm SC UPC 9 125um Single mode F P DFB laser 13T 5 dBm 3 to 12dBm typ 5dBm CWDM 0dBm 1dBm 1310nm or CWDM 10BaseT 100BaseTx 1000BaseT on RJ 45 connectors Compliant with IEEE 802 3 IEEE 802 3u IEEE 802 3ab and IEEE 802 3z Auto speed sensing and MDI MDI X 2 3 General Power Control 5V DC 2 9W Control system for access to setup and module status with BITE Built In Test Equipment nevion com 5 ETH1000 MKII Rev 1 3 Configuration ETH1000 MKII can be configured by DIP or from Flashlink Multicon GYDA 3 1 DIP control The tables below explain the functionality of the dip switches 1 Mbit Iz 1 Mbit IO 1Gbit oo Autoneg Cl O I oJ Gyda DIP GOL T Figure 3 Description 1 Enable 10Base T 2 Enable 100Base T 3 Enable 1000Base T 4 Auto negotiation on 1000Base X 5 Reserved 6 Reserved 7 Reserved 8 GYDA override DIP When DIP switch 1 2 and 3 are all on or off speed is set to auto DIP switch 1 enables disables 10Base T electrical connection DIP switch 2 enables disables 100Base T electrical connection DIP switch 3 enables disables 100
7. et traffic nevion com 10 ETH1000 MKII Rev 1 5 2 GPI Alarm Module status outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connector is shown in figure below GPI pinning Signal Name TPR Mode Status General error status for the Pin 1 Open Collector module Electrical Maximums for GPI outputs Max current 100mA Max voltage 30V Brown ue Pair d Green Blue Pair3 N Pair 1 Y N Orange T Pair 2 Figure 6 nevion com 11 ETH1000 MKII Rev 1 6 Laser safety precautions Guidelines to limit hazards from laser exposure All the available EO units in the Flashlink range include a laser Therefore this note on laser safety should be read thoroughly The lasers emit light at 1310 nm or 1550 nm This means that the human eye cannot see the beam and the blink reflex cannot protect the eye The human eye can see light between 400 nm to 700 nm A laser beam can be harmful to the human eye depending on laser power and exposure time therefore Be careful when connecting disconnecting fibre pigtails ends Never look directly into the pigtail of the laser fibre Never use microscopes magnifying glasses or eye loupes to look into a fibre end Use laser safety goggles blocking light at 1310 nm and at 15
8. ling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements ERA fk R i AGE SRK ZR ER Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE ETH1000 MKII O O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 This is indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the
9. ntifier gt lt block command gt lt set state gt lt set state gt act inact thru 3 2 1 5 Ethernet port lt identifier gt ethp lt status gt dis en cd ncd 10 100 1000 man auto full half auto mdi mdix auto mas sla auto lt block command gt dis en lt speed mode gt lt speed mode gt speed 10 100 1000 auto 3 2 1 6 Misc lt identifier gt misc lt status gt prog fin ovr nevion com 7 ETH1000 MKII Rev 1 4 Connector module The ETH1000 MKII has a dedicated connector module ETH1000 C1 This module is mounted at the rear of the sub rack The module is shown in the figure below ETH 18 0NC OPT TX Olt Olm GPI J10 OPT RX 10 100 1000Base T Figure 4 4 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www nevion com nevion com 8 ETH1000 MKII Rev 1 4 2 Terminal format support The different input and output ports on ETH1000 MKII can support a number of formats The table below shows the input and output signals on the back plane Terminal format support Terminal Function Supported Format Mode OPT RX Optical input 1000B
10. product is completely disconnected from power and signal connections All major parts are marked or labelled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices nevion com 15 mevion EC Declaration of Conformity MANUFACTURER AUTHORIZED REPRESENTATIVE Established within the EEA MODEL NUMBER S DESCRIPTION DIRECTIVES this equipment complies with HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY TECHNICAL CONSTRUCTION FILE NO YEAR WHICH THE CE MARK WAS AFFIXED TEST AUTHORIZED SIGNATORY MANUFACTURER ym Name Thomas hrbom Position VP of Quality Nevion Europe authorized signature Nevion Europe AS P O Box 1020 3204 Sandefjord Norway Not applicable ETH1000 MKII Gigabit Ethernet Media Converter Low voltage EU Directive 2006 95 EC EMC EU Directive 2004 108 EC RoHS EU Directive 2002 95 EC China RoHS WEEE EU Directive 2002 96 EC REACH EN 55103 1 1996 EN 55103 2 1996 Notified Competent Body Report no Not applicable 2011 AUTHORIZED REPRESENTATIVE Established within EEA Date of Issue 2011 06 30 Place of Issue Not applicable Sandefjord Norway Administration on the Control of Pollution Caused by Electronic Information Products 16