1. Install the adaptor Insert the connector fully to securely to the PLC module connect it securely with mounting screws PLC module Q68DAIN or others Conversion adapter between terminal block and connector FA Q6TCA Connection cable FA CBL ATQ8YA Insert the connector fully to connect it securely Ground the FG wire to a fc lt the panel Ground both ends of the cable p a WEEE 8860 60000000 Output signals 20 9 1 3 When cable with loose wires is used 4 T eeeele Wire the cable securely to the terminal block of PLC module Connection cable FA CBL ATYF Ground the FG wire to the panel EE _ T T 7 ae i T J I a i a a x an p z n gt CC L Ink other manufacturers PLC or others Insert the connector fully to connect it securely ra eS __ eT OGOOOOOOOE OGOGO COOOWOOOH oS f Output signals PW 21 10 PRECAUTIONS 1 Allow the product to warm up for ten minutes or more as a precaution though the Module works at the same time as powering it ON 2 Because the Signal conversion device had been calibrated in the initial state it is not necessary to be calibrated again However when the calibration is required for the conformity between the Device and other equipment to be connected perform the Zero Span adjustment as foll
2. Y non insulated Y insulated solderless terminal solderless terminal Unit mm 17 8 TARGET PLC MODULES AND CONNECTION CABLES PLC Module Model Connection Cable Module Model Model Q68DAIN FA CBL ATQ8YT MELSEC Q series Q68DAVN Analog output module Q68DAIN Conversion adapter Q68DAVN FA Q6TCA FA CBL AT Q8YA R60DAI8 FA CBL ATQ8YT MELSEC iQ R series R60DAV8 Analog output module R6ODAI8 Conversion adapter FA CBL ATQ8YA R60DAV8 FA Q6TCA FA ATB8YTB MELSEC AnS series A1S68DAI Analog output module A1S68DAV CC Link AJ65SBT2B 64DA FA CBL ATYF Analog output module General purpose analog output module of other General purpose analog output module FA CBL ATYF manufacturers PLC FA CBL ATS8YT 18 9 INSTALLATION METHOD 9 1 Connection to the terminal block type PLC module 9 1 1 When aconnection cable with terminal block is used Install the terminal block securely to the PLC module with mounting screws LC module 68DAIN or others R WOE i m OE i va Connection cable FA CBL ATQ8YT FA CBL ATS8YT Insert the connector fully to connect it securely Ground the FG wire to va IT the panel Ground both ends of the cable A o a a a a a a a a a a a BEBEEBEE il le TOE ORD RI RI KIRI RI QI TH 3 8866 080000000 Output signals 9 1 2 When conversion adapter between terminal block and connector is used
3. 14 5 MODULE INSTALLING ORIENTATION Vertical surface iene in landscape orientation Vertical surface installing in portrait orientation o9 kol ABEBE BEEEERE CELH IRIRI RIRI a OOOO E QOOQOOOOO Horizontal surface installing 6 EXTERNAL DIMENSIONS 6 1 Installation base FA ATB8YTB Unit mm EEE a e a a a G M G G a G a a A E 21 39 9 IAL ALAGA NI SI SI SY 8 9 41 4 6 2 Signal conversion device FA ATS Signal through device FA ATFTMXY Unit mm 14 5 2 Connector pin array right side view Lh sO ZO 7 APPLICABLE SOLDERLESS TERMINALS a Applicable Non insulated Insulated Non insulated Insulated wire size solderless terminal solderless terminal So eres terminal solderless terminal TGY1 25Y 3 R1 25 3N TG 1 25 3N ec TGV 25Y 3N Nichifu CO Ltd a TG 1 25 3 5N 1 25Y 3L TGY1 25Y 3L NTM 1 25Y 3 5 N1 2Y 3 TG 2Y 3 Vv N 1 25 2 0mm R2 3N TG 2 3N 2Y 3 5S TGY2Y 3 5S 1 25 B3A Japan Solderless 0 3 1 25mm 1 25 MS3 V1 25 MS3 eae Terminal Co Ltd 1 25 C3 5A oa anon 1 25 2 0mm2 2 MS3 V2 MS3 0 3 1 25mm Aren NE date EET NE vor 2a nae ae Nippon Tanshi o i 29 9 20 9 ppor ie R1 25 3 5SL RAP1 25 3ML vD 1 25355 Ep NTK RAV2 3SL l VDAV2 3 5SS 1 25 2 0mm2 R2 3SL pide eta ios ce Solderless terminal dimensions Unit mm Round non insulated Round insulated solderless terminal solderless terminal MIN 5 0 MIN
4. Block chart When the Signal through device is attached on the Base i Output signal from PLC 73 External output signal i I Output signal to monitor Modulation Recovery Terminal block side MIL20P connector side circuit i circuit 0 to 5VDC 4 to 20mADC 1 to 5VDC evel snil 0 to 10VDC ir K 1 A 10 to 10VDC Zero Span adjustment 2500 Power supply Sd circuit External power supply 7 24VDC 10 3 4 Signal conversion device from current input to current output FA ATSAM1YA FA ATSAM1YA020 FA ATSAM1YA420 Number of points 1 point 1 channel Input Input range 4 to 20mA PLC side Input resistance 2500 Standard Accuracy accuracy For full scale Temperature 0 015 C or less characteristic Output signal 0 to 20mA 4 to 20mA Permissible load 6000 or less resistance Output Disconnection detection None function Response speed 15ms or less Zero Span adjustment Zero adjustment range 2 to2 Span adjustment range 98 to 102 Power supply 24VDC 10 supplied from the Base Current consumption 24VDC 45mA or less Isolation method Transformer insulation Withstand voltage Between Input Output Power 750VAC for 1 minute 10MQ or more insulation resistance Weight About 40g About 40g 0 1 or less Surrounding air temperature 25 C 5 C 9 It indicates time until output signal reaches 90 for startup pulse input Block chart W
5. And attach or remove the Device in a correct procedure Failure to do so may damage the Device and or the Base causing them to drop or malfunction due to poor connection Use the product with no pressure applied to its connector Failure to do so may cause a breakdown or disconnection Attach the protection cover or device to an unused connector or slot of the product Foreign matter on an unused connector or slot without protection may cause a fire failure or malfunction Startup and Maintenance Precautions Do not touch any terminal while power is on Doing so can cause an electric shock or malfunction Be sure to shut off the external power supply for the system in all phases before cleaning the product or retightening the terminal screws the mounting screws of the connector or the fixing screws of the product Failure to do so may result in an electric shock or cause the product to fail or malfunction Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage the screw and or product causing the product to drop short circuit or malfunction Startup and Maintenance Precautions Do not disassemble or modify the modules Doing so may cause failure malfunction injury or a fire Use any radio communication device such as a cellular phone or PHS Personal Handy phone System more than 25cm 9 85 inches away in all directions from the programmable controller this pr
6. To prove the compliance with the EMC Directive and the Low Voltage Directive manufactures must issue an EC Declaration of Conformity and the products must bear a CE marking 1 Authorized representative in Europe The authorized representative in Europe is shown below Name Mitsubishi Electric Europe B V Address Gothaer strasse 8 40880 Ratingen Germany 2 How to use the FA Goods in compliance with the EMC and Low Voltage Directives For information on how to conform to the EMC and Low Voltage Directives when incorporating the compliant FA Goods into a user s machinery or system refer to EMC and Low Voltage Directives Compliant Manual_ 50D FA9010 108 1 INTRODUCTION This user s manual explains the specification handling etc of the Installation base FA ATB8YTB and the Signal conversion device FA ATS M1Y and the I O signal through device FA ATFTMXY all of which the Analog signal conversion module consists of By attaching the Signal conversion device to the Installation base the Analog signal conversion module insulates the designated signals 1 to 5VDC 4 to 20mADC between input and output terminals or among the channels convert them to analog output signals and outputs signals 2 GENERAL SPECIFICATIONS Operating ambient o Storage ambient D5 to 75 C temperature Operating ambient 5 to 95 RH no condensation humidity Storage ambient 5 to 95 RH no condensation humidity Somonmnalng JIS B 3502 1EC
7. l a ah oe a oon Output signal to PLC CON1 External input signal oon2 Output signal to monitor CON2 Terminal block side Y MIL20P connector side O to 10VDC LA It depends on an external input signal 0 to 5VDC 1 to 5VDC y E 10 to 10VDC When it is required to be matched with the Signal conversion device 1 to 5VDC Input type when signal is through I I I I ka o a a a a a a a a a a a a a a a I Output signal to PLC CON1 ooi Output signal to monitor CON2 MIL20P connector side External input signal 0 to 5VDC at 0 to 20mA gt 1 to 5VDC at 4 to 20mA 1 Terminal block side AI 0 to 20mADC E gt B c e When it is required to be matched with the Signal conversion device 4 to 20mADC fa I Terminals A and C should be shorted across i when current is converted to voltage Input type When the Signal through device is attached on the Base iS To tae ae a ae a Sai ae al n I A Output signal to PLC CON1 gnu Edemel oupi sighail input signal to monitor CON2 j j l Terminal block side MIL20P connector side AW I It depends on the output signal from PLC 0 to 10VDC s 0 to 5VDC 2 1 to 5VDC bhyi 10 to 10VDC 0 to 20mADC 5 4 to 20mADC Q When it is required to be 5 matched with the Signal f a conversion device 6 1 to 5VDC l 4 to 20mADC I External output signal Terminal block side 0 to 5VDC at 0 to 20
8. the specified torque range If any spade solderless terminal is used it may be disconnected when the terminal screw comes loose resulting in failure Check the rated voltage and terminal layout and then wire the product correctly Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure Do not install the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in malfunction due to noise Place the cables in a duct or clamp them if not dangling cables may swing or be inadvertently pulled resulting in damage to the product or cables or a malfunction due to poor connection Tighten the terminal screws within the specified torque range Undertightening can cause a short circuit fire or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Tighten the connector screws within the specified torque range Undertightening can cause a short circuit fire or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Connect the connector to the product securely Failure to do so may cause a malfunction When disconnecting a cable from the product do not pull the cable itself For a cable with connector hold the connector and pull it o
9. 61131 2 standards Under 5 to 8 4Hz Vibration resistance intermittent 10 a aa X Y vibration 8 4 to 150Hz an ons Under 5 to 8 4Hz continuous vibration 8 4 to 150Hz 4 9m s 0 5G Shack fecisanes Compliant with JIS B 3502 and IEC61131 2 147m s 15G 3 times each in X Y and Z directions Taa No corrosive gas atmosphere Operating 2 000 Installation location Inside the control panel Overvoltage category ll or lower Pollution level 2 or lower 1 Do not use or store the module under the atmospheric pressure greater than that at an altitude of Om 2 Indicates the section of the power supply to which the equipment is assumed to be connected between the public power grid and the machinery within the premises 3 This is a guideline indicating the degree of the generation of conducting substances in the environment in which a device is used Acceleration 3 PERFORMANCE SPECIFICATIONS 3 1 Installation base FA ATB8YTB hem Model name FA ATB8YTB Number of slots ee a a a a Terminal screw M3 screw Pitch of 7 62mm Self tightening screw with finger protector cover AWG 22 to 14 0 3 to 2 0mm with solderless terminal use 58 8 to 88 2N cm 6 to 9kgf cm 5 22 to 7 5lbf in UL standard conformity tightening torque 59N cm 5 22 Ibf in M4 x 0 7mm x 20mm or greater Tightening torque range 78 to 118N cm 8 to 12kgf cm Applicable DIN rail TH35 7 5Fe TH35 7 5Al IEC60715 comp
10. About 40g About 40g 11 It indicates time until output signal reaches 90 for startup pulse input Block chart When the Signal through device is attached on the Base Output signal from PLC i Output signal to monitor MIL20P connector side CON 1 to 5VDC CON l a Modulation Recovery z circuit circuit i Level shift ane Ns Current o Zero Span adjustment External output signal Terminal block side 0 to 20mADC 4 to 20mADC Power supply circuit External power supply 24VDC 13 4 DEVICE ATTACHING REMOVING 1 How to attach to the Base 2 How to remove from the Base 1 Set the Device to fit along the slot of the Base 1 Hold the Device by the attaching removing hook and the place on the opposite side so as to keep the hook pressed in O Attaching removing hook 2 Insert the Device until it is locked with the 2 Pull out the Device with the attaching removing attaching removing hook until the hook clicks hook pressed in Attaching p serene Beet Use an output signal conversion device with orange lines Using an input signal conversion device with purple lines incorrectly may damage the product 1 Hold the Installation base not the devices when transporting the Installation base with the Devices attached or when installing it to a panel 2 The dummy device is available for an empty slot of the Base as a dust proof countermeasure
11. Analog Signal Conversion Module Output type FA ATB8YTB FA ATS M1Y FA ATFTMXY User s Manual Thank you for purchasing the FA Goods product Before using the product please read this User s Manual and the relevant manuals carefully to ensure correct use MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED SAFETY PRECAUTIONS Always read these precautions prior to use Before using this product please read this User s Manual and the relevant manuals carefully and handle the product properly with full attention to safety The precautions presented in this manual are concerned with this product only For programmable controller system safety precautions refer to the user s manual of the programmable controller used In this manual the safety precautions are classified into two levels WARNING and N CAUTION Indicates that incorrect handling may cause hazardous N WARNING j o D conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous N CAUTION conditions resulting in minor or moderate injury or property damage Under some circumstances failure to observe the precautions given under AN CAUTION may lead to serious consequences Always follow the precautions of both levels because they are important for personal and system safety Design Precautions Configure external safety circuits to ensure that the entire system operates safely ev
12. en when a fault occurs in the external power supply the programmable controller or the product Failure to do so may result in an accident due to an incorrect output or malfunction Configure a circuit to turn on the programmable controller and then the external power supply If the external power supply is turned on first an accident may occur due to an incorrect output or malfunction Design Precautions Do not bundle the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in a malfunction due to noise At power on off voltage or current may be instantaneously output from the output terminal of this product In such a case wait until the analog output becomes stable and then start controlling the external device Installation Precautions Be sure to shut off the external power supply for the system in all phases before installation Failure to do so may result in an electric shock Installation Precautions Use the product in an environment that meets the general specifications described in this User s Manual Failure to do so may result in an electric shock fire malfunction or the product damage or deterioration Use an output signal conversion device Using an input signal conversion device incorrectly may damage the product Securely fix the product with a DIN rail or mo
13. hen the Signal through device is attached on the Base Modulation Recovery 2 Output signal from PLC Output signal to monitor ae H MIL20P connector side circuit pi rm A F External output signal 4 to 20mADC Terminal block side Level shift urrent 0 to 20mADC p circuit g S gt putput 1 4 to 20mADC ircuit Zero Span i l l i l adjustment i Power su pply circuit External power supply 24VDC 11 3 5 Signal conversion device from voltage input to voltage output FA ATSVM1YV lia Model name Fa ATsvM1Yvo5 FA ATSVM1YV15 FA ATSVM1YV010 FA ATSVM1YV1010 Number of points 1 point 1 channel Input Input range 1 to 5V PLC side Input resistance 1MQ or more Standard Accuracy accuracy For full scale Temperature 0 015 C or less characteristic Output signal 0 to 10V 10 to 10V Permissible load 25k ormare resistance Output 7 7 Disconnection detection None function Response speed 15ms or less Zero Span adjustment Zero adjustment range 2 to 2 Span adjustment range 98 to 102 Power supply 24VDC 10 supplied from the Base Current consumption 24VDC 45mA or less 0 1 or less Surrounding air temperature 25 C 5 C Isolation method Transformer insulation Withstand voltage Between Input Output Power 750VAC for 1 minute 10MQ or more insulation resistance Weight About 40g About 40g Abo
14. ing to the input resistance R of the connected external monitor equipment is detected The current value I can be calculated with the monitor output voltage V and the input resistance R by the following formula lI V R Example When R the input resistance of the connected external monitor equipment 5000 and V the measured voltage value 5V the formula for the detected current is as below 5V 5000 10mA 22 N FOR YOUR SAFETY This product has been manufactured as a general purpose product for general industry applications etc The product is not designed or manufactured to be used in equipment or systems in situations that can affect or endanger human life When considering this product for operation in special applications such as machinery or systems used in passenger transportation atomic power electric power aerospace or medical applications please contact your nearest Mitsubishi sales representative Although this product was manufactured under conditions of strict quality control the product shall be systematically provided with backup and fail safe functions when it is used in facilities where breakdowns of the product are likely to cause a serious accident or damage MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 1 13 5 Kudankita Chiyoda ku Tokyo Japan 102 8404 Our website URL http www mee co jp A Before using this product ensure the safety in case of failure We assume no respon
15. liant 24VDC 10 6mA or less Current consumption 24VDC not includeing current consumption by the conversion device the Signal through device the programmable controller and the monitor equipment Withstand voltage Between input output power supply 750 VAC for 1 minute 10MQ or more insulation resistance Weight About 320g 1 Attach the dummy device to an unused slot for covering an empty slot 2 When connecting a cable to the Module push the cable connector in until it is locked 3 When the signal through device FA ATFTMXY is used for output signal of 4 to 20mA from the programmable controller the voltage value according to the input resistance of the connected monitor equipment is detected for the monitor output The current value can be found by dividing the detected voltage by the input resistance Terminal block Applicable wire Tightening torque Module Mounting screws menue DIN rail External supply power Block chart coments aD OOOO OOOO SOSO00900006 D h aeeee SS SSS SS ES SS SS 0 ee epee clea OOOO AAAA O OOOWNMOOOODO O Connector for signal conversion device 1O 0 00 010 0 0 0 0 0 0 0 10 a li li li li li Connector for signal I O CON1 CON2 Connector pin array chart Top view CHI 20 CH1 CH2 CH3 CH4 CHS CH6 CH7 CH8 24VOUT 24GOUT CHloutput CH2output CH3output CH4output CH5output CHG
16. mA 1 to 5VDC at 4 to 20mA Terminals A and C should be shorted across Output signal to PLC CON1 H input signal to monitor CON2 MIL20P connector side 0 to 20mADC e When it is required to be matched with the Signal conversion device 4 to 20mADC 9 D aS gt o 2 18 D D gt fo 8 KA D p re D ta 0b a gt Ean Q 3 3 Signal conversion device from current input to voltage output FA ATSAM1YV lia Model name FA ATSAM1YVO5 FA ATSAM1YV15 FA ATSAM1YV010 FA ATSAM1YV1010 Number of points Input Input range 4 to 20MA PLC side Input resistance 2500 Standard Accuracy accuracy for full scale Temperature 0 015 C or less characteristic Output signal 0 to 10V 10 to 10V Permissible load 25KO ormare resistance Output Disconnection detection None function Response speed 15ms or less Zero Span adjustment Zero adjustment range 2 to 2 Span adjustment range 98 to 102 Power supply 24VDC 10 supplied from the Base Current consumption 24VDC 45mA or less Isolation method Transformer insulation Withstand voltage Between input output power supply 750VAC for 1 minute 10MQ or more insulation resistance Weight About 40g About 40g About 40g About 40g 8 It indicates time until output signal reaches 90 for startup pulse input 0 1 or less surrounding air temperature 25 C 5 C
17. oduct Failure to do so may cause malfunction Shut off the external power supply for the system in all phases before mounting or removing the module Failure to do so may cause the module to fail or malfunction or damage After the first use of the product do not mount remove the module and the cable more than 50 times IEC 61131 2 compliant respectively Exceeding the limit of 50 times may cause malfunction Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock Lock the control panel so that only qualified maintenance personnel can operate it Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the module to fail or malfunction Disposal Precautions A N CAUTIO When disposing this product treat it as industrial waste Transportation Precautions Avoid the shock that exceeds the shock resistance described in the general specifications during transportation as the product is a precision device Failure to do so can cause the product to fail EMC and Low Voltage Directives Compliance with the EMC Directive which is one of the EU Directives has been mandatory for the products sold in European countries since 1996 Additionally compliance with the Low Voltage Directive another EU Directive has also been mandatory since 1997
18. output CH7output CHBoutput Terminal block gt CS lt Q lt a oO ae Sp 9 oO se oS LS a Oo S a oO i u q N m z m o Earth 24VDC External power supply Notes Use the equipment with input resistance of adequate size for monitor output 1MQ or more is recommended The monitor output signal is 1 to 5V Use shielded electrical cables for external wirings An external power supply is connected to CON1 and CON2 Give the short circuit prevention processing when the power supply is not used Power supply terminal For 24V Pin No 3 or 4 For 24G pin No 1 or 2 Short circuit prevention processing 1 Set the connector on PLC and monitor equipment side to NC No connection 2 Insulate pins at wire end for NC Insulate each pin so that the conductive part is not exposed Base side PLC Monitor side 3 2 Signal through device FA ATFTMXyY Model name FA ATETMXY Number of points 1 point 1 channel Conversion type When signal is through When current is converted to voltage 2500 Resistance Resistor accuracy 0 1 or less Characteristic of 0 0025 C or less temperature of resistor Permissible I O signal Voltage 10V or less Current 20mA or less Weight About 30g 7 When current is converted to voltage short across terminals A and C of the Base terminal block Block chart When the Signal through device is attached on the Base l
19. ows Trimmer operation Turning to the right in clockwise for increasing a value Turning to the left in counterclockwise for decreasing a value Allow the product to warm up for ten minutes or more after powering it ON supply of the module Input the signal equivalent to 0 in the input range and adjust output signal to 0 by using the Zero adjustment trimmer Input the signal equivalent to 100 in the input rang and adjust output signal to 100 by using the Span adjustment trimmer Complete the Zero Span adjustment by repeating the operation in step 2 and 3 OA N O Input the signal of 25 50 and 75 in the input range and confirm the output linearity 3 When the monitor output is used the handling is different according to the usage condition of the device Please see the following tables about handling by each device PLC analog Signal conversion device Installation base Monitor output output ee Signal through device terminal block 1213 4 to Ato20mA EA ATS M1Y amp kK Various output 1 to 5V 1 to 5V signals 1 to 5V 4 to 20mA 4 to 20mA FA ATFTMXY when current is converted to voltage 1 to 5V 1 to 5V When signal is through 12 Use the measuring equipment with input resistance of adequate size for monitor output 1MQ or more is recommended 13 Do not short across connector pins No 1 to 4 to 24V 24G for monitor output of the Installation base FA ATB8YTB output type 14 The voltage value accord
20. sibility for consequential damages caused by failure of the product 50D FA9010 123 B Specifications subject to change without notice Published in May 2015 23
21. unting screws Incorrect mounting may cause the product to malfunction fail or drop When using the product in a vibration environment secure the product by screws Tighten the screws within the specified torque range Undertightening can cause the product to drop short circuit or malfunction Overtightening can damage screws and or the product causing the product to drop short circuit or malfunction Be sure to shut off the external power supply for the system in all phases before installing or removing the product Failure to do so may damage the product or cause the product to malfunction or fail Do not directly touch any conductive parts and electronic components of the product Doing so can cause the product to malfunction or fail Hold the Installation base when transporting the Installation base with the Devices attached or when installing it to a panel Holding the signal conversion device may cause the device to drop or fail Wiring Precautions Be sure to shut off the external power supply for the system in all phases before installation and wiring Failure to do so may cause an electric shock or damage the product Wiring Precautions Be sure to ground the FG terminal to the protective ground conductor dedicated to the programmable controller with a ground resistance of 100 or less Failure to do so may result in an electric shock or malfunction Use applicable solderless terminals and tighten them within
22. ut For a cable connected to a terminal block loosen the terminal block screws before removing the cable Failure to do so may result in a malfunction or damage to the product or cable Before connecting the cables check the type of interface to be connected Connecting the cables to a wrong interface or erroneous wiring may cause the product or external devices to fail Prevent foreign matter such as dust or wire chips from entering the product Such foreign matter can cause a fire failure or malfunction The product must be installed inside the control panel Connect the main power supply to the product inside the control panel through a relay terminal block Only qualified service personnel with knowledge of protection against electric shock should replace and wire the product Keep a distance of 100mm 3 94 inches or more between a thermocouple and the main circuit line or AC control lines Also keep the thermocouple away from a circuit that includes harmonics such as a high voltage circuit and a load circuit of an inverter Do not place the product near a device that generates magnetic noise When connecting the product to the programmable controller check that the product configuration is correct The modules may be failure or malfunction if the configuration is incorrect Attach the Device securely in the Base Failure to do so may damage the Device and or the Base causing them to drop or malfunction due to poor connection
23. ut 40g About 40g 10 It indicates time until output signal reaches 90 for startup pulse input Block chart When the Signal through device is attached on the Base Output signal from PLC i Output signal to monitor MIL20P connector side CONT Modulation Recovery circuit circuil 1 External output signal Terminal block side 1 0 to 5VDC 1 to 5VDC i CON Level shift avon es circuit ey 10 to 10VDC gt Zero Span adjustment Power supply circuit External power supply 24VDC 12 3 6 Signal conversion device from voltage input to current output FA ATSVM1YA FA ATSVM1YA020 FA ATSVM1YA420 Number of points 1 point 1 channel Input Input range 1 to 5V PLC side Input resistance 1MQ or more Standard Accuracy accuracy For full scale Temperature 0 015 C or less characteristic Output signal 0 to 20mA 4 to 20mA Permissible load 6000 or less resistance Output Disconnection detection None function Response speed 15ms or less Zero Span adjustment Zero adjustment range 2 to 2 Span adjustment range 98 to 102 Power supply 24VDC 10 supplied from the Base Current consumption 24VDC 45mA or less 0 1 or less Surrounding air temperature 25 C 5 C Isolation method Transformer insulation Withstand voltage Between Input Output Power 750VAC for 1 minute 10MQ or more insulation resistance Weight