Home
USB Wire Deformeter - SISGEO North America
Contents
1. Erase Memory button deletes only the saved acquisitions leaving unchanged the logging parameters This is useful when once downloaded the saved acquisitions the user want to continue logging with unchanged setup and need to avoid data overwriting DOWNLOAD DATA Clicking on the Download data button all the device saved acquisition will be written to a comma separated value csv file The name of the file is selectable in the form that appear just after the button click It is best practice to erase the device memory after the data download SAVED FILE FORMAT The data is saved as a comma Separated value file In the first line there is the device name in the second line there are the column titles of the data and from the third line onward there are the downloaded data In every line representing an acquisition the first number is the serial number and is zeroed every time the acquisition process starts so the first line starts always with one If the first number of the first line is not one an overwriting could be occurred The second number of the line is the position value expressed in millimeters followed by the temperature recorded when the measure was taken Then there is the date time of the measure Device name SISGEO n value mm temp C date dd mm yyyy time hh mm ss 1 16 374 23 18 02 2011 9 31 40 2 16 374 23 18 02 2011 9 31 50 3 16 374 23 18 02 2011 9 32 00 Rev 0 07 11 2011 EE Pace TE
2. USER S MANUAL AND MAINTENANCE Rev 0 07 11 2011 al Page NOTE OF SYSTEM UTILIZATION MANUAL PURPOSE ENVIROMENTAL CONDITIONS CONFORMITY DECLARATION AND EC MARKING MAINTENANCE WASTE DISPOSAL SIMBOLOGY IDENTIFICATION PLATE USB WIRE CRACKMETER OVERVIEW DESCRIPTION DIMENSION INSTALLATION AND SETTING POWER SUPPLY BATTERY CHANGE USB CONNECTION TO A PC WRCDATA SOFTWARE MANAGEMENT INSTALLATION GUIDE WRCDATA SOFTWARE MANAGEMENT USER GUIDE DEVICE POSITION LOGGING SETUP DOWNLOAD DATA SAVE FILE FORMAT TECHNICAL SPECIFICATIONS ASSISTANCE REPAIRS AND MAINTENANCES PHONE ASSISTANCE TECHNICAL ASSISTANCE ON SITE FOR SUPPLIED INSTRUMENTATIONS TRAINING Rev O 07 11 2011 Pag 3 Pag 4 Pag 4 Pag 4 Pag 4 Pag 5 Pag 5 Pag 5 Pag 6 Pag 6 Pag 6 Pag 7 Pag 7 Pag 7 Pag 8 Pag 9 Pag 13 Pag 14 Pag 14 Pag 14 Pag 15 Pag 15 Pag 16 Pag 17 Pag 17 Pag 17 Pag 17 Pag 17 2 Page NOTE OF SYSTEM UTILIZATION To ensure a safe and efficient functioning please read the following instructions carefully before use Any unauthorized modification is considered a total responsibility of the user In addition to the standards listed above the user must comply with the existing legislation on safety and health of employees in the workplace Check the product for damages caused by transport Verify that your package includes all standard accessories and any accessories required In case contact the
3. manufacturer The use of the equipment shall be done only after the proper connection and following the configuration needed so the user must carefully perform all the operations described herein SISGEO will not be liable for inconveniences damages accidents etc due to lack of knowledge or non application of the requirements contained in this manual The use any possible maintenance or repair of the equipment is allowed only to skilled and authorized operators These operators must be physically professionally and intellectually capable For information or orders of spare parts always specify the data reported on the identification plate showing the serial number inside each device When replacing parts use only ORIGINAL SPARE PARTS The use of unoriginal SISGEO spare parts may cause irregular functioning and dangers for people and objects The product is not fit for installation in small and or unventilated environments with a high humidity range or in presence of inflammable or explosive liquids All the instruments and the equipment furnished are not suitable for installation in potential dangerous area or when the use of explosion proof components is foreseen The electrical connections must be executed by a qualified installer observing the effective regulations The manufacturer reserves the right to make changes in case of any manufacturing or commercial need without notice It will attempt to ensure that user manuals a
4. CHNICAL SPECIFICATIONS Displacement sensor Temperature sensor Data logger Interface Power supply Working temperature Wire strength Protection degree Weight Case Electromagnetic compatibility Rev O 07 11 2011 Potentiometer Stroke 80mm Resolution 0 003 mm Linearity hysteresis lt o 1 F S Range of measure 20 80 C Resolution 1 C Conversion A D 15 bits Memory EEPROM Safety data CRC redundant Storage 51062 measurements or 18236 measurements with redundant CRC Period of configured acquisition 10 sto g1hours Connection mini USB connector Software form in Microsoft Windows Battery CR2032 3Volts Life 4 years 1 saving per hour 10 60 C or less depending on the battery features 10 N IP65 2N aluminium 2004 108 CE BYE Pace ASSISTANCE Sisgeo S r l is aware of the importance covered by the after sales assistant service therefore Sisgeo Technical Support is structured to offer the following services REPAIRS AND MAINTENANCES During the warranty period we assure that the equipment supplied is free from defects in materials for a standard and appropriate use Repairs and or recalibrations should always be carried out at SISGEO factory or by personnel trained and authorized by SISGEO In case of repair and or recalibration please send us the device and every accessory in the container provided in order to prevent damage from shocks during transport This proce
5. ack evolution in buildings geomechanics and joints Stroke 80 mm Power supply is internal with battery and it may be connected to a PC with a mini USB cable for setting and for data saving DIMENSION 27 35 COVER OPENING SCREWS 50 FOR BATTERY CHANGING 2 5 f i i i COUPLING SCREW pe Wi N ee y 9 Ak 4 LO 8 2 ian wo o N we AIN SCREW CAP WITH SCREWDRIVER uaig J N FOR USB CONNECTOR i y R que Y A COVER OPENING SCREWS N A FOR BATTERY CHANGING ME L 4 O44 942 FIXING BORES Rev 0 07 11 2011 6 Page INSTALLATION AND SETTING The crackmeter has to be mounted on a flat surface and has to be fixed across the fracture to be monitored Place if possible the case of the instrument in a higher position as to the wire ends The two fixing bores allow an easy and quick installation of the crackmeter The stainless steel wire has to be fixed through the coupling screw M6 or the hollow positioned at the end of the wire Avoid bending or distortion of wire Do not exceed the maximum stroke of the wire Do not release the wire of the transducer too rapidly In case the USB Wire Crackmeter is exposed to external agents snow ice animals branch or gravel fall it is necessary to cover it with proper protection POWER SUPPLY The crackmeter is power supplied internally with a 3Volts battery t
6. dure involves the filling out of the form on our website www sisgeo com to the link assistance repairs once inserted the request a confirmation with the related authorization code will be sent to the e mail address indicated Note the material has to be packed properly and sent in door to door basis freight to client charge to SISGEO S r l Via F Serpero 4 F1 20060 MASATE MI Attn to Technical Assistance Office Tel 39 02 95764130 Fax 39 02 95762011 e mail assistance sisgeo com PHONE ASSISTANCE Telephone support for installation configuration of equipment measurement systems and Software TECHNICAL ASSISTANCE ON SITE FOR THE SUPPLIED INSTRUMENTATIONS Technical support for the installation of monitoring systems with its commissioning and start up through the add of specialized technician s teams TRAINING Possibility of training at our Factory or at site related to the installation procedures the system configuration and the use of measurement systems Rev 0 07 11 2011 BWA Pace
7. installer will install WWRCD ata Software Management to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder fc Programmi Sisgeo WRCD ata Install WRCData Software Management for yourself or for anyone who uses this computer Everyone Just me You could confirm the default folder or change it to a different one clicking on the Browse button Once finished click on Next to continue A confirmation window will appear click Next to continue the installation ie WRCData Software Management Confirm Installation The installer is ready to install WRCData Software Management on your computer Click Next to start the installation Rev 0 07 11 2011 al Page At the end of the process the following window will appear click on Close to terminate the installation procedure Now the WRCData Software Management is installed i WRCData Software Management Installation Complete WRCData Software Management has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Close Rev 0 07 11 2011 EVA Page WRCDATA SOFTWARE MANAGEMENT USER GUIDE Before start the program connect the USB Wire Crackmeter to the PC with an USB cable Then go to Start gt All programs gt Sisgeo gt WRCData and c
8. lick on WRCData Software Management If the USB Wire Crackmeter is correctly connected appears the following main window DEVICE SISGEO POSITION LOGGING SETUP Sampling period Logging start 2 Immediately O Start time Number of readings before overwnting Max saves 51042 Last date 24 02 7011 6 16 06 C Safe Data CRC Erase Memory Set BATTERY COTO Download data Figure 1 WRCData Sofware Management main window BER Pace Rev O 07 11 2011 DEVICE This frame displays the device name which could be changed clicking on Change name The device name is also written in the header of the saved acquisitions file to identify the device POSITION In the center of this section is displayed the present position in mm read by USB The top line shows the date and time of the device internal clock while in the bottom there are the number of the saved acquisitions and the current temperature LOGGING SETUP In this section you could view and change all the logging parameters of the USB Wire Crackmeter In the Sampling period field is possible to setup the hours h the minutes m and the seconds s between two consecutive acquisitions If all are set to o no acquisition will be done All changes are sent to the device only when the button Set is clicked In the Logging start section is possible to set when the USB Wire Crackmeter will start to
9. re updated in order to reflect functional product revisions Rev 0 07 11 2011 EJ Page MANUAL PURPOSE This manual has been designed by the Manufacturer to provide the necessary information regarding the device to those who are authorized to carry out safely its installation maintenance dismantling and disposal Other than adopting good technical construction methods the information should be read carefully and strictly applied Inobservance of this information could cause risks for the health and safety of people and economical damage This manual reflects the state of skill of the instrument at the time of input on the market however the manufacturer reserves the right to make changes add or improve the manual without giving any reason to hold the present manual inadequate ENVIROMENTAL CONDITIONS Temperature setting min 10 C max 60 C It is forbidden to use the instrument other than its specific use and in potentially explosive conditions or where anti explosive elements are used CONFORMITY DECLARATION AND EC MARKING The instrument answers to the following Communitarian Directives 2004 108 EC Electromagnetic compatibility with reference to general Rules EN61000 6 2 immunity in industrial environment and EN50081 1 emission in residential environment MAINTENANCE The instrument does not needs a particular maintenance except cleaning to do only with a soft cloth dampen with ethylic alcohol or water Do not u
10. save the acquisitions If the Immediately option is selected the acquisitions start as soon as the device is disconnected from the PC Otherwise selecting the Start time option is possible to choose the logging start date and time Also this section changes are sent to the device only when the button Set is clicked Every acquisition is saved in a circular buffer so if the free space is depleted before a download the oldest data are overwriting To avoid this the last date before overwriting is displayed This date is valid only if the parameters were sent to the device or the memory was deleted The last logging option is the Safe Data Activating it every acquisition is double saved and checked by a CRC code Usually the device records the measure on two memories when one is full it starts to use the other In case of a memory failure about half of the recorded data could be lost Using the safe data option the device writes every single acquisition in both memories so in case of a memory failure none of the recorded data will be lost The price of this reliability is that the number of acquisitions before overwriting is halved Once changed the logging parameters these must be sent to the USB Wire Crackmeter clicking on button Set A warning window will inform the user that all the saved acquisitions will be deleted and the device clock will be synchronized with the PC Rev 0 07 11 2011 14 Page The
11. se hydrocarbon solvents petrol diluents etc the using of these products could affect the proper functioning of the instrument Rev 0 07 11 2011 EN Page WASTE DISPOSAL According to the European standard 2002 96 CE the disused instrument must be disposed in a correct way The recyclable materials are recovered in order to avoid the environmental damage For more information please contact your waste disposal service or the instrument a retailer SIMBOLOGY Here are the symbols used in this manual to alert the reader Attention This operation must be executed only by specialized personnel Pay particular attention to the following information IDENTIFICATION PLATE Each USB Wire Crackmeter 0D314FV8000 has one identification plate This reports the product registration Serial Number SISGEO liar italy Number It is important to communicate this information when requesting information concerning the product Rev 0 07 11 2011 EJ Page USB WIRE CRACKMETER OVERVIEW Mint USB connector Stainless steel wire SISGEO instrument code DESCRIPTION Crackmeter with data logger fully independent for the storage of the displacement and temperature They are made of a precision rotating potentiometer operated by the means of a winding or unwinding of Stainless steel wire Special features of the crackmeter are the simplicity of setting and the limited eye catching They are suitable for monitoring of cr
12. your PC you could skip to page 10 otherwise the following form will appear click on the Accept button to continue the installation US WRCData Software Management Setup For the following components NET Framework 3 5 Please read the following license agreement Press the page down key to see the rest of the agreement MICROSOFT SOFTWARE SUPPLEMENTAL LICENSE TERMS MICROSOFT NET FRAMEWORK 3 5 FOR MICROSOFT WINDOWS OPERATING SYSTEM B View EULA for printing Do you accept the terms of the pending License Agreement f you choose Dont Accept install will close To install you must accept this agreement Dat ara then the NET 3 5 will be installed on your PC with the appearing of this window El rose Rev O 07 11 2011 i WRCData Software Management Welcome to the WRCData Software Management Setup Wizard The installer will guide you through the steps required to install W RCData Software Management on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Bact Next gt click on Next and the installation folder will be requested with this form Rev 0 07 11 2011 aol Page Select Installation Folder The
13. ype CR2032 Also with low battery level it is possible to export the saved data trough a PC connection In any case data are not lost To replace the battery is necessary screw off the two screws on the top cover lift it to access the battery holder After replacing the battery screw the cap BATTERY CHANGE Before change of battery is necessary connect the device to a PC otherwise the device will lost date and time Rev 0 07 11 2011 yA Page USB CONNECTION TOA PC To acces to USB connector is necessary screw off the cap by the means of a large cut screwdriver The initial setting the configuration and saving operation of data can be simply managed through simple Microsoft Windows software The PC can be connected to the crackmeter via mini USB connector placed inside the instrument near the battery Screw the cap after data transfer Rev 0 07 11 2011 EJ Page WRCDATA SOFTWARE MANAGEMENT INSTALLATION GUIDE WARNING all the following steps requires Administrator privileges Before installing the WRCData Software Management please install the device driver double clicking on CDM20802_ Setup exe a background shell window will appear and close automatically after the drivers installation nc Ta i ao o BB DotHetFx35 WindowsIns setup exe setup msi COM20502 Se tup exe To install the WRCData Software Management double click on the setup exe icon then if the NET Framework 3 5 is present on
Download Pdf Manuals