Home
The all-in-one field sync tester
Contents
1. ep yg M erue FDD LTE 3G PRC The a e e 9 6e e o e 1 Seay PMP ES gt e EPC RNC eme X or Ethernet es ES k 1 Core e e o J IP MPLS or Ethernet Backhaul jentine IP MPLS or Ethernet Backhaul Macro eNodeB a 1 Small Cells PTP Slave PTP SyncE E1 T1 10 MHz 1pps eranl vee0e 0 0e 0 006006000000009009 GPS Validate 1 5us phase accuracy requirement for LTE A Macro Cell Small Cells e _ Slave e PTP E1 T1 10 MHz NTP lt 1pps s SyncE i GPS Check whether PTP NTP delivers Sync within specs Clock Module Specifications Predefined Signal Clock Types 1pps PTP slave recovered clock 8 kHz frame clock 64 kHz 64 kbit s EO DSO 1 544 MHz 1 544 Mbit s T1 DS1 clock data 2 048 MHz 2 048 Mbit s E1 clock data 5 MHz 10 MHz Freq reference 25 MHz 125 MHz 156 25 MHz SyncE clock rate 34 Mbit s E3 45 Mbits s DS3 155 52 MHz 155 Mbit s STM 1 STS 3 clock data User defined Clock Types User defined signal types from 0 5 Hz to 200 MHz in 1 Hz steps Note symmetrical unipolar clock signals Measurement Ports Number of Ports 2 per module Connector BNC Impedance 75 ohm
2. 4 Cal Ref Freq Uncertainty GPS disciplining Built in GPS Module 12 channels TRAIM GPS receiver high sensitivity Time Accuracy to UTC 25 ns at 10 after 24 hours lock Frequency Accuracy 2x107 averaged over 24 hours GPS Disciplining Modes Always disciplining always in holdover disciplining only between measurements External References Frequency Reference Input std Input Frequency 10 MHz 5 MHz or 1 MHz Voltage Range 0 1 Vrms to 5 Vrms Impedance approx 50 ohm External 1pps Timing Input Voltage Range OV to 0 8V Low 2V to 3 3V High into 50 ohm Required Accuracy 100 ns to UTC GPS Timing Reference Antenna Input N type connector DC feed 45V on center pin to active GPS antenna Output References Reference Frequency Output Ref Frequency 10 MHz sine wave Output Levels 1Vrms in 50 ohm Impedance approx 50 ohm 1PPS Output Source Internal Rubidium oscillator Output Logic Levels TTL levels in 50 ohm E1 T1 Output Module Connector Clock BNC Data Isolated BNC Frequency 2 048 1 544 MHz Output Level Acc to G703 10 1 2 V 10 in 75 ohm Interfaces USB Device Port Connector Std USB type B USB Version 2 0 USB Host Port Connector Std USB type A Max Supply Current 400 mA USB Version 2 0 Ethernet Communication Port RJ45 10 100 Base T Protocol DHCP HTTP FTP VNC Remote Operation Remote operation via VNC open browser and enter IP address Event Log On screen log of measurement start s
3. and 4x ToD display measurements analysis Measure Time of Day ToD Phase and Frequency Calnex Solutions is a global leader in Test and Measurement solutions for next generation telecom networks Our products help to prove new technologies for Mobile Backhaul and Carrier Ethernet networks For more information on the Calnex product family and to take WWW calnexsol com advantage of Calnex s extensive experience in Packet Sync and OAM testing technologies contact Calnex Solutions today tel 44 0 1506 671 416 2 email info calnexsol com Calnex Calnex Solutions Ltd 2013 Insight and Innovation
4. Insight and Innovation The all in one field sync tester Lab quality performance in an easy to use portable package Just two steps to run the test 1 Run Signal Check to auto discover signals 2 Start all measurements at the same time No need to carry a truck load of equipment it s now all in one Small enough to take on flights as hand luggage Remote operation and monitoring from NOC Office Big touchscreen and user friendly interface Train Rb in the lab then switch off drive to the test site and start testing Pass Fail ITU T and Vendor limits for easy analysis Capture and Replay send measurement files back to Vendor Labs to fix issues Detailed measurement report in pdf format Applications TDM VN STM 1 STM 1 E SONET SDH Sa WDM OTN oS STM 1 E Up to 6 Le measurements Jj at the same time 100 al l bservation Window s Show Li abels 0 01 0 1 1 10 Obs al opopo Resolution LTE A TDD LTE PRTC gt i wu Py x IP MPLS z wu PS or Ethernet Core T BC T BC e e e EPC o e e e 9 Copo lt x RR pull SERE iil ij mM ia 4 al
5. VSWR 2 1 or 1M ohm Voltage Range 5 00 V Sensitivity 60 mVpp Signal Type Symmetrical pulse Clock signal Unsymmetrical repetitive pulse Clock signal HDB3 coded data Data signal AMI B8ZS B3ZS Data signal Test Modes Masks can be applied for TIE MTIE and TDEV graphs MTIE and TDEV Masks 1pps Time Error limit e g 1 5 us PRC SSU SEC Masks for G811 G812 G813 clocks ETSI 300 462 3 Networks According to G 823 6 824 6 8261 6G 8261 1 SyncE According to G 8261 G8262 ANSI standard DS1 and OC N masks User defined Defined by the user Graph Display Display Modes TIE MTIE TDEV ADEV FDEV RTIE MRTIE Update Rate approx once second Number of Graphs Up to 6 graphs of the same type can be over laid on screen Color coded Masks on Screen Up to 6 MTIE MRTIE and TDEV masks according to selected test mode Pass Fail result available for each mask Ethernet Module Specifications Synchronous Ethernet SyncE clock measurement Conformance to G 8261 and G 8262 masks MTIE TDEV Additional metrics display FDEV ADEV MRTIE Extract and display ESMC message SSM Generate and change ESMC IEEE1588v2 PTP Forward Sync PDV Reverse DelReq PDV and Network Delay Raw PDV vs time and distribution graphs a Selected Packet PDV vs time and distribution graphs luster band packet selection Pseudo Slave or Monitor Mode Layer 3 IPv4 UDP Multicast Unicast 5nsresolution timestamp better than 1 ns ac
6. curacy Captured PDVs can be replayed on Calnex Paragon X for troubleshooting NTP Forward Server PDV in Monitor mode Raw PDV vs time and distribution graphs 5ns resolution timestamp better than 1 ns accuracy Captured PDVs can be replayed on Calnex Paragon X for troubleshooting Measurement Ports Number of Ports 1 per module Connector RJ45 for 10 100 1000 bT SFP SFPs not supplied 100M 1GbE Platform Specifications Reference Clock Built in Rubidium reference or external reference input 1 5 or 10 MHz Resolution 200 ps rms Sample Rate Up to 100 Sa s depending on number of parallel measurements Internal Data Storage Up to 5M TIE values External Data Storage On USB memory stick Start Stop Via START STOP key Signal Check Parameters Signal type Clock Data or Unknown Frequency for clock signals Pulse width for data signals Voltage peak peak min 120 mVp p Display Color TFT 8 4 800x600 pixels resistive touchscreen Specification is subject to change without notice Platform Specifications continued Internal Time Base Stability holdover Stability Versus Temperature 20 to 26 C lt 1x10 typ 07 to 50 C lt 1x10 Ageing Rate 24h 5x10 per month Warm up Stability 12 min to lt 1x10 Calibration Principle Closed Case Calibration with automatic adjustment of the Rubidium timebase using Cs based or GPS controlled Rb based or built in GPS reference Calibration Uncertainty 2x10
7. net module PTP NTP SyncE Includes SyncE ESMC testing 100M and 1GbE up to 3 per unit Option 620 IEEE1588v2 and NTP PDV measurement software one license per main unit Option 630 Internal battery backup for Rubidium Optional Accessories Option 802 One year warranty extension Option 803 Two years warranty extension Option 75 120 ohms balanced RJ45 to 75 ohms unbalanced BNC impedance converter balun Related Products 66666Sos P du um AA g 8 E MN M M MM Calnex Paragon X Calnex Paragon t Calnex Paragon m All Capture and Measure features of Paragon X amp 1588v2 and NIP PDV and Standards and Vendor Metrics Pass Fail evaluation Speed up test time and reduce test complexity with multi clock Measurements e Test 1588v2 PTP SyncE NTP CES and OAM up to 10G a Stress test equipment with real network profiles from field tests to debug network issues Measure multiple outputs from a chain of Boundary Clocks BCs and Slave Clocks a Sync E Wander measurement to Prove 1588v2 PTP Sync E CES ITU T limits Pseudowire NTP etc implemen tations to ITU T G 8261 etc 4 x Frequency SyncE E1 1T1 2 048M 10M Wander Clock measurements 1pps ToD measurements E1 T1 including MTIE TDEV to m Test 1588v2 Ordinary Clocks ITU T limits Boundary Clocks and Transparent Clocks 4x Phase 1pps accuracy measurements a Thru mode Network capture
8. top duration alarms loss of data loss of communication link etc Log can be saved as text file Report Generation Printable custom designed measurement report in pdf format Security Password secured access to STA 61 Environmental Data Temperature Operating 0 C to 40 C 30 C when charging Rb backup battery Safety EN 61010 1 2011 CAT II Pollution degree 2 Measuring category I CSA C22 2 No 61010 1 04 UL 6010 1 2004 EMC EN61326 1997 A1 1998 CE Power Supply Line Voltage 100 to 240 Vrms 10 47 Hz to 63 Hz 60 W Optional Battery Backup 5 hours autonomy for rubidium only to maintain internal timebase accuracy during transport Mechanical Data The chassis is suitable for field use and can be operated on a bench lying down or on a floor standing up The cabinet is shock resistant using bumpers Dimensions w x h x d 320 x 388 x 126 mm 12 6 x 15 3 x 5 Weight Net 6 kg 13 Ib Shipping 7 kg 15 Ib with transport case 9kg 20 Ib Specification is subject to change without notice Ordering Information Calnex Sentinel Sync Analyzer with built in GPS receiver Needs one or more input modules Option 610 Option 611 Included with shipment User manual on CD line power cord GPS antenna antenna cable 20m hard transport case calibration certificate 1 year warranty and support Built in Options Option 610 Clock module 1PPS E1 T1 any clock up to 200 MHz up to 3 per unit m Option 611 Ether
Download Pdf Manuals
Related Search
Related Contents
学校用備品購入仕様書 Projet Socket Calculatrice - Ingénierie des Réseaux - std-svn-uppa Operating Instructions/Bedienungsanleitung/ Mode d'emploi Clair-TD1866 Manual Turbosound TCS COMPACT SERIES Portable Speaker User Manual OM, Automower, 305, 308, 2015-01 MANUAL DE INSTRUÇÕES TA-Nr. 011251 02/06 Änd. User Manual - TAF MiFID v1.2 Interface via www.bourse.lu - e arva Evo3 1213モデルの取扱説明書 (日本語 2MB)PDFファイル Copyright © All rights reserved.
Failed to retrieve file