Home
LPC2 OT1 User Manual
Contents
1. 12 VDC 150 mA Power supply input Table 3 TRM TRM Min Max LCD contrast setting trimmer Table 4 LON1 LON1 1 N C Not connected LON1 2 N C Not connected LON1 3 LON FT 10 LON communication LON1 4 LON FT 10 LON communication LON1 5 N C Not connected LON1 6 N C Not connected Table 5 LON2 LONZ 1 GND Ground LON2 2 N C Not connected LON2 3 LON FT 10 LON communication LON2 4 LON FT 10 LON communication LON2 5 N C Not connected LON2 6 N C Not connected Table 6 COM COM 1 DTR Data Terminal Ready RS232 Programming controlling monitoring COM 2 GND Ground COM 3 N C Not connected COM 4 Rx Receive RS232 ec Programming controlling monitoring COM 5 Tx Send RS232 e Programming controlling monitoring COM 6 RTS Ready To Send RS232 Programming controlling monitoring 1 Supply wiring power supply wires must have cross sectional area at least 0 75 mm Minimum temperature rating of wire insulation must be 85 C 2 Use middle two pins for LON network connection 2aa Longo programmable controller LPC 2 OT1 operation terminal 5 Table 7 Earth SMARTTEH LIVING SYSTEMS Earth Functional earthing This connection is for functional not protective purposes only Table 8 LEDs amp Buttons On OK PWR Green LED indicates LPC 2 0T1 Off power off or fuse blown CPU state Blink i
2. e SMART EH LIVING SYSTEMS 6 USER MANUAL Longo programmable controller LPC 2 0T1 operation terminal Version 4 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail infoesmarteh si www smarteh si e a Longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS Written by SMARTEH d o o Copyright 2005 SMARTEH d o o User Manual Document Version 004 March 31 2006 o AR Longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our author
3. IOUS riesco qaae Ge Dean ie ace caso NIB sas 6 3 3 Module eh EEN 7 A TECHNICAL SPECIFICATION KE 8 EE EE 9 AA E En M 10 3 iii o a longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS 1 DESCRIPTION LPC 2 0T1 operation terminal module is a human machine interface HMI It is a part of the LONGO Programmable Controller LPC 2 system with illuminated LCD display keyboard status LEDs and buzzer Its general purpose is to execute HMI application software and communicate with LON network Module is powered with external 12 VDC supply For this purpose additional power supply LPC 2 505 is required Green LED PWR indicates LPC 2 0T1 operation terminal module CPU state Red LED SER indicates CPU LON state Push button P B is used for LON service pin activation refer to the Table 8 Application program is easy to load control and monitor directly from the LPC Manager tool using standard RS232 PC port and PMC programming cable attached to LPC 2 0T1 connector COM Connection of the LPC 2 0T1 module to LON network is done using LON1 and LON2 connectors Standard network integration tool e g LonMaker for Windows is used for designing installing and maintaining interoperable LonWorks control networks LPC 2 0T1 module is intended for dose mounting but it also can be mounted on custom enclosure machine or other provided place using four screws refer to the Mounting instructions latte
4. for application 32 kB Network controller Echelon FT 3150 Network type ANSI CEA 709 3 1999 LON FT 10 78 kbps Network topology star daisy chain bus loop mixed free Connection type RJ12 FM connector Application upload port RS 232 max 38 4 kbps data bits 8 parity none stop bit 1 flow control none Connection type RJ12 FM connector Dimensions L x W x H 145 x 200 x 43 mm Weight 600 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Transport and storage temperature 20 to 60 C Fuse T 1A L250 V Pollution degree 2 Protection class IP 30 3 For detailed memory configuration see MC3 help file in LPC Composer application y Longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS 9 CHANGES The following table describes all the changes to the document Date V Description 31 3 2006 003 The initial version issued as LPC 2 0T1 module UserManual 11 5 2010 004 Updated warranty permanence e a Longo programmable controller LPC 2 0T1 operation terminal SMARTTrEH LIVING SYSTEMS 6 NOTES
5. ized representative Warranty does not include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 MANUFACTURER SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia EN Longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS Index Longo programmable controller LPC 2 0T1 operation terminal 1 DESCRIPTION mE 1 JA 401 9 2 INSTALLATION 3 2 1 CONNECUON SEN Mtra ee code ER 3 3 4 MOUFDEIHS JOSEFUCE
6. nternal fault Pulse off OS reset Off configured SER Red LED indicates LPC 2 0T1 Blink not configured CPU LON state On with P B pressed service pin message sent P B Push button LON service pin ASE PI essa ER SNS WHEN pressed e a Longo programmable controller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS 3 2 Mounting instructions Figure 3 Housing dimensions 18 g 8 SaaS O O 80 44 57 2 35 6 145 e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply Mounting instructions 1 5 Mount LPC 2 0T1 module to the provided place GEWISS dose GW24238 or similar Mounting screws are supplied together with LPC 2 0T1 module Connect communication wires to the connectors according to connection scheme in Figure 2 Connect 12 VDC power supply wires to the connector according to connection scheme in Figure 2 If other then LPC 2 505 power supply is used ensure that its output is SELV and limited power circuit Connect earthing wire to the provided place Switch ON 12 VDC power supply Power PWR green LED should switch on according to the Table 8 a ongo programmable contr
7. oller LPC 2 0T1 operation terminal SMARTEH LIVING SYSTEMS 3 3 Module labeling Figure 5 Labels on housing Label 1 Label 2 LPC 2 MC3 P IN 225MC304001001 S N MC3 S9 0500000190 D C 16 05 C Label 1 description 1 LPC 2 MC3 is the full product name 2 P N 225MC3040001001 is the part number 225 general code for LPC 2 product family MC3 short product name 04001 sequence code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 description 1 S N MC3 S9 0500000190 is the serial number MC3 short product name S9 user code test procedure e g Smarteh person xxx 0500000190 year and current stack code 05 year last two cyphers 00000190 current stack number previous module would have the stack number 00000189 and the next one 00000191 _ x aa Longo programmable controller LPC 2 OT1 operation terminal SMARTTEH LIVING SYSTEMS 4 TECHNICAL SPECIFICATIONS Table 8 Technical specifications Supply voltage 12 V DC screw type connectors for stranded wire 0 75 to Connection type 4 2 5 mm Max power consumption 4W Application controller Intel C51 based Data programme memory Organization 8 bit Non volatile memory avail for data 32 byte RAM avail for application 5 5 kB FLASH EPROM avail
8. r in this document NOTE For proper system configuration and data allocation please refer to LPC Composer software help menu e a Longo programmable controller LPC 2 OT1 operation terminal SMARTER LIVING SYSTEMS 2 FEATURES Figure 1 LPC 2 0T1 operation terminal Table 1 Technical data IEC 61131 3 LD ladder programming language Application loading controlling and monitoring Easy to use human machine interface HMI Illuminated character LCD display Keyboard with 24 keys and status LEDs Integrated buzzer 12 VDC power supply additional power supply needed Integrated LON FT 10 network line driver Different mounting possibilities m Longo programmable controller LPC 2 0T1 operation terminal 3 INSTALLATION 3 1 Connection scheme Figure 2 Connection scheme SMARTTEH LIVING SYSTEMS Power supply 12 VDC Ce P TRM LCD contrast trimmer Min O Max mm aA FUSE jt 12V e PS j 1A T SMART 2 0T1 NM Operation terminal LON2 ee oe LON1 l LON network LON network PMC programming cable S 2saa Longo programmable controller LPC 2 OT1 operation terminal e SMART EH LIVING SYSTEMS Table 2 PS PS 1 1 0 VDC Power supply input PS 2 12V