Contents
1. application Display indication Remark Welcome to the service II Lo Lo 7 A program 1 The password is cleared User Manual ACS 900 Assistance Page 11 The ultrasonic does not work Please check if the ultrasonic is installed as follows Remark Welcome to the service program Ultrasonic is not installed Ultrasonic is installed Press button 1 Indication is changing between US inst and US uninst Press button 1 till display indication shows you US inst 1 Toggle Press button Check and reinstall programs 1 to 6 as required User Manual ACS 900 Accessories Ultraschall 17142 A W Lo i d VO A WOOO LS ARAN E d A ll A do HERR O id f Ab IB N User Manual Page 12 230 V 17102 110 V 17101 17136 cover couvercle Deckel 17135 Glass jar bocal en verre Glaswanne 17938 Wave breaker Brise remous Wellenbrecher for basket up to 80 pour panier jusqu a 480 f r Korb bis 80 ACS 900 Accessories Page 13 Art Nr Zubeh r zu ACS900 No d art Accessoires ACS900 80 mm Accessories ACS900 part No 1x 17122 5 x 17123 User Manual ACS 900
2. e till all the jars are installed 7 Press EXIT ACS 900 change over to standby position 8 Load the baskets with the parts you _ want to clean insert in lower basket holder and close fixture 9 The machine is ready for service You can start a test sp for example Programm 7 4 A ani E AT 4 E AAA e A O E 10 Press Display says Which clean program 11 Press 7 Display shows you datas in programm 7 12 Press e Cleaning program 7 is running User Manual ACS 900 Fixed cleaning programs are fixed programs factory set Buttons They can not be changed Descriptions of the programs Page 4 Program 7 Spin drying time Position turntable OT f f T o Ultrasonic Cleaning time Ultrasonic yes in minutes 1 Minute Basket Cold air movement typ Drying time Program 8 5 S US TIME MODE 5 Warm air Positions which are not used Programm 9 1 2 3 4 5 S US TIME MODE CR Cm Cm Cm Om oe C Hz 50 25 33 5H I U L Warm air Positions which are not used User Manual ACS 900 Select your own cleaning program Page 5 Important Button 1 6 can be used for cleaning procedures 4 5 6 Programming of ACS 900 is possible in standby status or during cleaning program il al 3 Explanation of the settings Time Acc Spin SE Sor SS Drying Time programming positions 1 5 0 9 minutes O Position is inactiv 1 9 basket stays in the j
3. 2 3 4 5 S US TIME MODE ma Ca a a a II em Ce D 1 gt 50 41 42 63 9H 1 U Is cleaning program of button 1 correct 1 If yes gt gt gt gt gt gt gt gt gt gt gt gt gt gt Programming of button 1 is installed and stored Programming of button 2 6 can be done in the same way On page 5 you will find all the adjustments which are possible User Manual ACS 900 Start cleaning program Page 9 Key application Display indication Which clean Program Indication of the dates from the selected program Cleaning program is started and whole run time is Indicated Press button Press button 1 u Press button Interruption Cleaning program You can interrupt cleaning at any time 1 Press button BREAK 2 Press button EXIT User Manual ACS 900 Placing a password Page 10 Only the person who knows the password is able to change the cleaning program Any password can be used Installation can be done during standby modus or cleaning program Enter a password for the first time Key application Display indication Remark Which clean Program Which program Change password WOL Enter your personal Enter new password password 1 9 Code max 8 digits r Enter new pw again Enter new pw again In case of a mistake enter 1 9 Difference new try right no OU H Now pw is installed and stored Clear the password Key
4. Greiner vibrograf A G Tel 41 62 923 44 33 Q Weststrasse 69 Fax 41 62 923 18 46 abe Sei SCHEED Email greinervibrograf datacomm ch G reiner zen Internet www greinervibrograf com english User Manual ACS 900 Helmut Klein GmbH Steinenlandstrasse 1 Tel 49 7231 9535 0 T KLEIN LIII DE 75181 Pforzheim Fax 49 7231 9535 95 HELMUT KLEIN ZA Germany Elektronische Zeitme technik User Manual ACS 900 Contents Contents Introduction ACS 900 Loading of the jars Fixed cleaning programs Select your own cleaning program Display explanation Programming mm Programming mm Start cleaning program User Manual ACS 900 Page Page Page Page Page Page Page Page Page 4 2 3 4 5 6 T 8 9 Page 10 Page 11 Page 12 Page 13 19 Page 1 Introduction ACS 900 Page 2 Unpack the ACS 900 and install it on the working place Open the front doors and remove all packing material inside the instrument Main switch off Connect the ACS 900 with the delivered power cable to the Power socket Please observe the Voltage 230 or 115 Volts marked on the label Switch on the main power switch The basket holder moves upwards the turntable turns to Pos 5 in front and the bracket of basket h
5. ar between 1 9 minutes Movement typ of the basket 0 5 O Basket turns slowly in one direction half of the time and in the reverse direction the other half of the selected time No agitation movements are very slowly and stretched movements are slowly and less strectched mean movements quick and short movement very quick and very short movement O AUN Ht ot i ull Spin 1 5 minutes Spinning is effected in the upper part of the jars selected time is between 1 5 minutes The selected time is for all jars Drying warm or cold warm air Switch on or off with button 1 H F cold air Remark When jar 4 is selected temperature of warm air is already in the right position when basket runs for drying Ultrasound Programming of ultrasound is effected with Pos 1 of turntable With Button 1 you can switch on or off Movement status 0 is suggested during cleaning with ultrasonic User Manual ACS 900 Display explanation Page 6 When you press key and 1 of the keys 1 _ 9 the programs which were entered are shown on the display as you can see in the following example Spining time Position turntable g m Ultrasonic Button No 5 S US TIME MODE Cleaning time Ultrasonic yes in minutes 1 minute Basket Cold air movement typ Drying time Spining time Position turntable p T I Ultrasonic button No Cleaning time Ultrassonic no In minutes 1 bis 5 minutes Basket Warm air move
6. ment typ Drying time User Manual ACS 900 Programming Page 7 Key application display Indication Remark Which clean Program j 5 Lo EI j Laj 2 6j 3j EI Which clean Program Which program Pos 1 gt Time Acc Pos 1 gt Time 5 Acc Time pos 1 Y i El Pos 1 gt Time 5 Acc 0 Pos 2 gt lime Acc Pos 2 gt Time 4 Acc V i d Time pos 2 Pos 2 gt lime 4 Acc 1 Pos 3 gt lime Acc Pos 3 gt Time 4 Acc V De Time pos 3 Pos 3 gt Time 4 Acc 2 Pos 4 gt Time Acc Pos 4 gt Time 6 Acc Time pos 4 V d U S S S S gt lt lt lt lt 2 D D D D 3 S S 5 5 5 5 e F F F D F F F F lt lt lt lt Le Le O O Pos 4 gt lime 6 Acc 3 Pos 5 gt Time O Pos 5 gt lime 9 Time pos 5 User Manual ACS 900 Programming with button 1 1 exampel Page 8 Key application display indication Remark By pressing button 1 fan Fan OFF 1 ON for drying is activated or i deactivated By pressing button 1 heat for drying is Heat OFF 1 ON activated or deactivated Spin btwn stations Spining time 1 bis 5 minutes Spin btwn stations 1 US OFF 1 ON By pressing button 1 ultrasonic is activated or desactivated US ON 1 OFF Arrow to the right gt gt gt gt gt gt gt gt gt gt gt gt gt gt For controlling fixed programs 56000888 Which clean Program 1
7. older turns to front The Instrument is now in standby Position Press the LOAD key on the keyboard to install the Ultrasound and the glass jars Standby Position Position 5 of turnable is in front Bracket of basket holder is in frontl A arrow in the display is moving from left to right The machine is ready to start Caution Do not place anything on top to the instrument that can block the ventilation The ventilator fan that evacuates the fumes during the cleaning process from the machine is located on the top When process is finished ventilator stops automatically after 5 min Preparation of the baths Pos 1 cleaning bath with or without ultrasonic Pos 2 cleaning bath or 1st rinsing bath Pos 3 rinsing bath Pos 4 cleaning or lubrication bath Pos 5 remains empty drying position Take care not to exceed the maximum level of fluids indicated on the jar and ultrasonic Quantity 0 55 1 User Manual ACS 900 Loading of the jars Page 3 1 Press LOAD O Display shows S Next or Pos 1 5 Basket holder moves upwards Turntable turns to the Pos 1 2 Press ENTER If you operate 1 2 3 4 or 5 instead of ENTER the turntable turns directly to the corresponding position 3 Put ultrasonic in Pos 1 If ultrasonic is not requested you can install a cleaning jar instead 4 Press ENTER Turntable turns to the nex Position Pos 2 5 Put jar in Pos 2 6 Continue as discribed in point 2