model: dry 300 & 500 plastik wall-mounted

image

Contents

1. aa a ne i E 7 dehumidifier suffered frost damage 8 electric tension source is insufficient improper other IN CASE OF ANY UNCERTAINTY YOU MAY HAVE PLEASE FEEL FREE TO CONTACT US NOTE When applying applicable warranty the registration card that ensures applicable warranties must be returned In case you cannot find the registration card of your dehumidifier please contact the Service department of Microwell Ltd indicated your name address and serial number of your dehumidifier The registration card will be then sent to you for filling in In case you have any service or technigue related guestions please specify the model number and serial number of your dehumidifier These information will help us in making proper diagnosing of your unit and the service can be performed with a minimum time delay TRANSPORT INSTRUCTIONS The dehumidifiers must be transported only in the original packaging and in a vertical position Make sure that the dehumidifier cannot turn over or fall down during transportation Do never put the dehumidifier aside It may lead to serious compressor damage No claims are accepted in case of any damage caused by transportation When receiving the product delivered to you please check whether the package is not damaged If any kind of objections occurs please make a proper do
2. Relative humidity Relative humidity 8 WARRANTY CONDITIONS following exceptions stated by Microwell Ltd apply within the warranty No claims will be accepted if 1 The dehumidifier is used in an incorrect way not as described in this manual 2 The dehumidifier is installed in an incorrect way not as described in this manual 3 The dehumidifier was put to operation by an unauthorized person 4 The air flow through the dehumidifier is out of the defined borders 5 The water flow through the dehumidifier is out of the defined borders 6 The water s pH level and or chemical condition is out of the defined borders eee ii im im im i o o O mm mm 7 bj Acidity pH level pH 7 4 0 4 Total alkalinity as CaCO3 ppm 80 120 Total hardness as CaCo3 ppm 100 300 Total melted dry mass ppm max 3000 Maximal saline content wt wt 6 Free chlorine range ppm 1 0 3 0 Superchlorination ppm max 30 ppm max 24 hours Bromine ppm 2 3 Baquacil ppm 25 50 Ozone ppm 0 8 1 0 Maximum copper content ppm max 2 Aquamatic single purifier ppm max 2 Tarn clean purifier ppm max 2 Sherwood purifier ppm max 2 j 2 Na kis
3. INSTRUCTIONS FOR USE 3 1 Humidity control by means of the built in humidistat The built in humidistat is located at the bottom of the unit on the left The built in hygrostat reads the humidity of the incoming air and depending on the set value does or does not switch the compressor on In the central position of the regulator the unit secures the average relative humidity of 60 In indoor swimming pool halls the correct air humidity should range from 55 to 65 Decreasing the humidity under this range is not desirable either from the physiological viewpoint or from the viewpoint of protection of the building Moreover it increases the electricity consumption The humidistat can be controlled by the user A view at the hygrostat scale 3 2 Humidity control by means of a remote humidistat upon request The dehumidifier may be upon request equipped with a remote humidistat In such case the dehumidifier has two humidistats One of them is built in the dehumidifier the other one is remote in a separate casing The dehumidifier is primarily controlled by the remote humidistat provided that the built in humidistat in the dehumidifier is set for a higher value than the remote humidistat If the built in humidistat were set for a lower value than the remote humidistat it would take over and the control of the dehumidifier would not react to the signals from the remote humidistat Therefore it is best to set the built in humidistat
4. BT 1 E Vi nd Ag p Pi ii WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL Thank you for your decision to purchase our device Please read this user manual carefully before switching on the device Please keep the instructions in this practical guide for your guick know how We do not take responsibility or warranty in case of damage loss or impairment caused by incorrect usage or by usage for other purposes not described in this manual Contents 1 Safety measures 2 Specifications for use Instructions for use Instructions for maintenance Servicing the unit Installation guide Technical data NO Ui CJ IN SAFETY MEASURES Do not manipulate with the device with wet hands Do not spray any flammable substances into the eguipment this might lead to fire Do not clean the device with water Do not clean the eguipment with aggressive cleaning agents this might lead to damage or deformations When cleaning plastic parts do not use any cleaning agents unsuitable for the cover of the dehumidifier household cleaning agents solvents bleaching agents benzene diluents rough cleaning powder cresol chemical agents Instead sweep the dehumidifier cover with a soft cloth or a sponge Never throw or insert any objects into any hose or opening The cover is made of plastic Do not manipulate with lighted cigarette cigarette ashes or any other kin
5. Dehumidifier MICROWELL type DRY 300 Plastik DRY 500 Plastik DRY 300 Silver DRY 500 Silver DRY 300 Metal DRY 500 Metal The sampletested the essential safety requirements of the following European New Approach Directives 2004 108 EC 2006 95 EC EMC Directive Low Voltage Directive For this the following documents exist Final Report No 730146 2007 Observing all relevant New Directives and providing the Manufacturer s Declaration Conformity above mentioned product can be labelled with CE marking Pie any 26 09 2007 750146 TSU Pie any p Krajinsk cesta 2929 9 f Ing Anna ONDR IKOV riadite ka posudzovania zhody v robkov Product Conformity Assessment Director Telef n 421 33 7957111 Fax 421 33 7723716 e mail web gt 21m mm TUT Ld iuis alt NT M e ik dem nx xa D LA MICROWELL Ltd SNP 2018 42 927 01 a a Slovakia Phone 421 31 7020 540 1 Fax 421 31 7020 542 E mail microwell microwell sk www microwell eu Distributed by VERSION 2012 08 15
6. PIPING 1075x65mm DRY 500 PLASTIK MOUNT THE GRID SHORTEN THE PIPING AS NECESSARY 7 TECHNICAL DATA DRY 300 PLASTIK DRY 500 PLASTIK 60 W For swimming pools with maximum surface area DEHUMIDIFICATION PERFORMANCE at 30 and 60 RH 1 24 h at 30 and 70 RH 1 24 h at 30 C and 80 RH 24 h Operating temperature ranqe 66 82 101 22 35 22 35 Operating humidity range 20 100 20 100 Air flow m h 440 740 Noisiness in 1 m distance dB A 4 44 Heat output 1900 3500 Power consumption 70 1000 Voltage V HZ f 230 50 1 230 50 1 Operating current Starting current 4 4 15 8 7 5 30 Protection 16 Coverage 44 CYSY 3C x 1 5 CYSY 3C x 2 5 d 18 d 18 780 x 653 x 255 1245 x 653 x 255 850 x 735 x 345 1315 x 735 x 345 40 46 60 69 0 75 28 5 8 5 28 5 8 5 2 7 02 e NJ O Tees Conductor Condensate drain minimum inside diameter o 3 Dimensions width x height x depth Dimensions of package width x height x depth Weight net in package Refrigerant R 410 A Max pressures in the system HP LP 3 o G O Dehumidifier efficiency rate DER OPTIONAL EXTRAS Remote control wireless with an adjustable dial ves no css D u y yes LPHW heater element heat output at water temp 90 709 W 2000 4000 Connecting thread of the LPHW heater element thread male G 1 2 male G 1 2 WALL MOUNTED SWIMMING POOL DEHUMIDIFI
7. to the value of 70 9o RH or more The built in humidistat fulfils a back up function should the remote humidistat fail to function or should its battery go flat It is best to set the remote humidistat to the value in the extent of 55 to 65 9o RH Decreasing the humidity under this range is not desirable either from the physiological viewpoint or from the viewpoint of protection of the building Moreover it increases the electricity consumption Left Remote control receiver which is built into the dehumidifier by means of distribution connectors Right External hygrostat with a built in radio transmitter Location The remote humidistat is to be located in the most humid area of the room usually in a corner directly opposite the dehumidifier This guarantees that the humidity of any area of the swimming pool hall will not exceed the humidity value set in the remote humidistat The regulator must not be placed on a metal plate because the plate would disturb the high frequency signal and thus prevent the communication with the remote controlled switch in the unit Automatic mode If the air in the room exceeds the desired humidity value the regulator will switch the dehumidifier on Changing the battery The remote humidistat is charged by a 2 1 5V alkaline battery Only alkaline batteries may be used since non alkaline batteries might leak and damage the whole appliance The durability of a battery is approximately 12 mo
8. 00 atthe bottom of the unit Release the screws pull the bottom part of the cover toward yourself and then by lifting it shortly rake down the cover from the rear plate To mount the cover carry the procedure out in reverse order 6 4 Securing the position of the unit The unit is designed in such a way that it can be securely mounted and will hold in its place even if lifted accidentally In the top edges of the back plate there are screw holes for safety screws which are accessible after dismounting the front fibreglass cover Arrows indicate the safety screw holes in the back plate A safety screw is fastened through a screw hole in the back plate into a wall plug in the wall This will prevent the unit from being accidentally pulled out and falling off the mounting bracket At the same time it will secure the perpendicular position of the unit and align the unit with the wall BACK PLATE 10 KL gt 78 m 5 Q s s w 4 m SAFETY SCREW HOLES WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL 6 5 Drainage of condensate Condensed water is drained from the unit by the force of gravity It is necessary to situate the unit in such a way that there is sufficient declivity for the drainage of condensed water The condensation product must be drained through a siphon into a sewer or into the outside environment It is strictly forbidden to drain the condensed water back into the swimming pool as it may be polluted b
9. ER USER S MANUAL DIMENSIONS DRY 300 PLASTIK FRONT VIEW ATTACHMENT OF THE LPHW HEATER ELEMENT TO THE DISTRIBUTION OF THE HEATING WATER MODELS WITH THE LPHW ELEMENT ONLY THREAD G THE POSITION AGAINST GETTING LOOSE FROM THE BRACKET BRACKET FROM THE REAR 8 _ 35 pro E a pm pe P Ea te u 50 100 CONDENSATE DRAINAGE FROM THE REAR L POWER SUPPLY FROM THE REAR CYSY WIRE 3 x 1 5 mm VIEW FROM BELOW PIPING WITH MINIMUM INTERNAL DIAMETER OF 18 mm SIDE VIEW THE POSITION AGAINST GETTING LOOSE FROM 7 THE BRACKET FROM THE REAR 255 DIMENSIONS DRY 500 PLASTIK FRONT VIEW ATTACHMENT OF THE LPHW HEATER ELEMENT TO THE DISTRIBUTION OF THE HEATING WATER MODELS WITH THE LPHW HEATER ELEMENT ONLY THREAD G 75 THE POSITION AGAINST GETTING LOOSE FROM THE BRACKET FROM THE REAR BRACKET SIDE VIEW THE POSITION AGAINST GETTING LOOSE FROM m THE BRACKET FROM THE REAR Ee FE 2 50 100 CONDENSATE DRAINAGE FROM THE REAR WITH MINIMUM INTERNAL DIAMETER OF 18 mm POWER SUPPLY FROM THE REAR CYSY WIRE 3C x 1 5 mm VIEW FROM BELOW WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL WIRING DIAGRAM MODEL MICROWELL DRY 300 PLASTIK withou
10. ata Control unit Switch unit Power suppl 2 x 1 5 AA alkaline batteries 230 0 1 Battery longevi min 1 year according to battery type Impact from 20 up to 30 m in building 100 m in public place Carrier freguence 433 92 Mhz Setting range of reguested humidi 15 85 r h Setting range of reguested temperature 5 39 C Operating difference 5 r h Measurement precision 1 5 r h Measurement sensivity of humidity 1 r h Measurement sensivity of temperature 0 1 Adjustable range hysteresis of humidity switching 1 9 rh Adjustable range hysteresis of temperature switching 0 1 0 9 C Enclose temperature 20 40 C Switching capacity 250V 8V Contact voltage switching Dimensions 71 x 71 x 26 mm 81 x 81 X 36 mm Protection type 54 WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL 3 3 Control of the fan Under the inside cover of the unit there is two position fan mode switch In the first position the fan runs even if the compressor of the appliance has stopped continuous operation of the fan In the second position the fan only runs simultaneously with the compressor periodical duty of the fan The continuous operation mode of the fan is preferable since the humidity reader built in the device continuously reads humidity and therefore a greater accuracy is reached At the same time continuous operation of the fan results in better air circulation in the room The installation work s
11. ater is supposed Connection of the unit to the mains and its protection must correspond with the applicable standards Electrical supply of the unit must be carried out by a protective isolating transformer or it must be protected by a current protective switch with a nominal differential cut off current not exceeding 30 mA 2 000 of at least 300 mm from the floor 2 000 1250 1250 _ gt SWIMMING POOL 1250 OUTSIDE THE ZONES In the distance of 1250 mm or less from the swimming pool edge the bottom edge of the unit must be in the height of 2500 mm from the swimming pool surface if it is embedded under the floor then 2500 mm from the floor Atleast 1250 mm i e outof the reach of the hand from the lateral edge of the wash basin the minimum height of 1200 mm above ground It cannot be placed above the wash basin SWIMMING POOL WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL OUTSIDE THE ZONES If the unit is in the distance of less or egual to 1250 mm horizontally from the edge of the swimming pool then it must be raised up to the height of 2500 mm from the swimming pool surface if the pool is embedded under the floor then the unit must be raised up to the height of 2500 mm from the floor 6 7 LPHW heater element to order The LPHW heater elements are supplied only to order Connection of the hot water heater element onto the LPHW plumbing is carried out similarly
12. ction of the appliance to the electric mains must be carried out by a certified electrician An example of preparation of electric power supply condensate drainage and mounting of the bracket WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL LOCATION THE EOUIPMENT The location must be in compliance with the 384 7 702 51 60364 7 702 standard It is recommended to situate the unit outside zones 0 1 and 2 In case the unit is situated into zones 2 or 1 it must be adhered to the HD IEC standard ZONE 1 IPX4 Swimming pools which are not cleaned by jet water in the distance of 1250 to 2000 mm from the swimming pool edge the unit must adhere to the HD IEC standard and in the height ZONE 2 IPX2 Swimming pools which are not cleaned by jet water In the distance of 2000 to 3500 mm from the swimming pool edge the unit must adhere to the HD IEC standard and a minimum 150 mm elevation above the ground is reguired for sufficient air flow Installing the unit on the floor is prohibited At least 1250 mm i e out of the reach of the hand from the lateral edge of the shower cabinet It cannot be placed above the shower cabinet OUTSIDE THE ZONES In the distance of at least 1500 mm from the vertical plane around the jumping platforms diving boards and 2500 mm above the highest surface where persons are likely to stay It is inevirable to locate the unit outside the zones where cleaning by jet w
13. cumentation ofthem WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL NUM ARTE MER i B ety DE i A A IMS Fe EST s a TT i nm i is m m pti Aen un A U 1 Technick sk obn stav Pie any p Notifikovan org n Identifika n slo 1299 Autorizovan org n Reg islo SKTC 104 SK03 TS U O iuga p NM T US cy P TN p Notified Body Identification No 1299 Authorised Body Reg No SKTC 104 SK03 CERTIFIK T ZHODY CONFORMITY CERTIFICATE CJNo 712990054 pre v robcu alebo jeho autorizovan ho z stupcu v Eur pskej nii to the manufacturer or his authorised representative in the European Union MICROWELL spol s r o SNP 2018 42 927 01 a a Slovak Republic V robok ur enie typu Product and designation of type Odvlh ova vzduchu MICROWELL typ DRY 300 Plastik DRY 500 Plastik DRY 300 Silver DRY 500 Silver DRY 300 Metal DRY 500 Metal Presk an vzorka spl a z kladn po iadavky na bezpe nos pod a nasleduj cich eur pskych smern c Nov ho pr stupu Smernica o EMC Smernica o n zkom nap ti 2004 108 EC 2006 95 Existuj to nasleduj ce dokumenty z vere n protokol 750146 2007 Dodr uj c v etky pr slu n smernice ES a poskytuj c ES Vyhl senie v robcu o zhode vy ie uveden v robok mo e by opatren ozna en m
14. d of fire in vicinity to this part Use this device exclusively for the intended purpose as described in the attached instruction manual Do not use parts which are not recommended Never block the air opening of the product Protect the air openings from clogging by particles hair etc When the device is not running correctly smoke smell etc shut down the device by a circuit breaker in the switchboard Repair and dislocation must be performed exclusively by a service technician Before cleaning the device switch off the circuit breaker in the switchboard Do not place any objects onto the device When you do not intend to use the device for a longer time switch off the circuit breaker SPECIFICATIONS FOR USE The units are designed especially for use in indoor swimming pools spas and saunas They can also be very useful in laundries drying rooms and elsewhere The Microwell DRY 300 PLASTIK is designed for halls with a swimming pool surface area of up to 30 m The Microwell DRY 500 PLASTIK is designed for halls with a swimming pool surface area of up to 60 m The condition for using the unit is maintaining the room temperature within the range between a minimum of 229C and a maximum of 35 Ideally the air in the room should be 2 3 warmer than the water in the swimming pool EXHAUST GRID t UNIT COVER HYGROSTAT _ V INTAKE GRID WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL
15. ion installed on the dehumidifier s cover In the configuration for installation behind the wall conduit adapters are screwed onto the dehumidifier s cover The adapters are delivered for passage through the wall of the length of 400 mm In the place of installation they are shortened from the side of the swimming pool as necessary View from the adjacent room View from the swimming pool hall WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL SHORTEN THE AS NECESSARY MOUNTING FROM INSIDE REINFORCE THE PIPING TO THE VALUE OF 65 MM AND FROM THE OUTER SIDE FOAM HAS TO BE GLUED TO THE 5 AFTER HARDENING OF THE PUR FOAM REMOVE THE FORTIFICATION AND MOUNT THE GRID 615 DRY 300 PLASTIK_ i mawar PIPING 615x65mm DRY 300 PLASTIK PIPING 1075x65mm DRY 500 PLASTIK PANGED CONNECTION x 22272 22 71075 DRY 500 PLASTIK aa IM a a a aa LA Pr a s fa 4 gt ELBOW 1359 615x65mm DRY 300 PLASTIK ELBOW 135 1075x65mm DRY 500 PLAS io 25 mm WIDE FLANGE DEHUMIDIFIER xl 1 029 545 DRY 300 PLASTIK 1005 ORY 500 PLASTIK _ MOUNTING FROM INSIDE REINFORCE THE PIPING TO THE VALUE OF 65 MM 22 22 2 AND FROM THE OUTER SIDE FOAM HAS TO BE GLUED TO THE MASONRY PIPING 615x65mm DRY 300 PLASTIK AFTER HARDENING OF THE PUR FOAM REMOVE THE FORTIFICATION AND
16. nths The regulator automatically checks the level of its battery If the battery voltage drops under the permitted value battery sign on the display of the humidistat comes on It is then necessary to change the battery as soon as possible If the battery is not changed and goes flat the dehumidifier will be controlled by the built in humidistat in the dehumidifier WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL Automatic function during a power failure Ifthe power supply of the dehumidifier is interrupted during the operation of the remote humidistat then once the power supply is renewed the dehumidifier will automatically return to the latest setting This recovery will occur within 15 minutes after the power supply return Setting In the setting mode the brightness of the LCD display can be set By pressing or buttons the LCD display s brightness is added or reduced This setting is for all displays Setting of code and test switching relay for heating control and for dehumidification control Data display about the manufacturer Average temperature and humidity display for the last 32 hours Hysteresis setting for 19 humidity range 0 1 0 99 temperature range Heating switch on off Next Dehumididication Confirmation switch on off Back Back Add brightness Humidity hysteresis Information about Statistics Reduce brightness Temperature the manufacturer hysteresis Back Back Technical d
17. t inbuilt wireless humidistat DRY EASY 200 inbuilt wireless humidistat DRY EASY 200 MECHANICAL HUMIDISTAT orange FAN MODE SWITCH db FAN S 2 nie MECHANICAL 1 HUMIDISTAT orange O FAN MODE SWITCH brown C3 gt FAN black WIRELESS HUMIDISTAT beet LOW DRY EASY 200 PRESSURE ka LOW PRESSURE L PRESSOSTATIL 6 gre brown brown 2 67 rO L WITCHING Ej K1 SWITCHING O N Kil k RELAY RELAY O1PE COMPRESSOR blue WIRING DIAGRAM OF MODEL MICROWELL DRY 500 PLASTIK without inbuilt wireless humidistat DRY EASY 200 inbuilt wireless humidistat DRY EASY 200 MECHANICAL FAN MODE SWITCH HUMIDISTAT oe 1 SWITCH 2 3 slow speed re 12 grey FO FAN i M FO slow speed gre M WIRELESS HUMIDISTAT black black black LOW LOW DRY EASY 200 PRESSOSTA PRESSOSTAT L D L TERMINAL BOARD brown OIL E blue io IN green vellow O IPE VL blue COMPRESSOR blue CONDENSOR COMPRESSOR CONDENSOR Note Producer reserves right to make changes on wiring WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL OUTPUT DIAGRAM DEHUMIDIFICATION DRY 300 PLASTIK 24h 60 50 E 5 40 30 o 20 10 0 15 20 25 Air temperature OUTPUT DIAGRAM OF DEHUMIDIFICATION DRY 500 PLASTIK 24h 15 20 25 Air temperature WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL
18. talled in compliance with the local installation and electrical installation regulations 6 1 Location of the unit To ensure maximum efficiency it is necessary to install the unit as high above the ground as possible It is forbidden to install the unit onto the ground It is essential to ensure good air circulation by allowing at least 150 mm of free space under the unit and at least 200 mm of free space above the unit For the purposes of maintenance it is further necessary to allow at least 200 mm of free space on both sides of the unit WALL MOUNTED SWIMMING POOL DEHUMIDIFIER USER S MANUAL 6 2 Mounting the unit Theunits have a self supporting structure and are remarkably easy to install A part of the unit accessories is also an installation bracket which must be fixed onto the wall The axis of the fixation openings is 210 mm lower than the top edge of the unit The fixation openings 420 mm apart DRY 300 PLASTIK or 360 mm apart DRY 500 PLASTIK Once the bracket is mounted to the wall it is possible to mount the unit without disassembling its cover Model DRY 300 PLASTIK TOP EDGE OF THE UNIT BRACKET SPIRIT LEVEL 210 420 gt MOUNTING HOLES Model DRY 500 PLASTIK TOP EDGE OF THE UNIT BRACKET SPIRIT LEVEL 210 360 360 MOUNTING HOLES 6 3 Dismounting and mounting the cover The cover can be dismounted after releasing two screws DRY 300 or three screws DRY 5
19. to the installation of radiators On the feeder pipe it is connected by a control valve and on the return pipe by a closing screw joint The LPHW is not supplied with a control valve and a screw joint these are supplied by the supplier of the heating THREAD G MALE OPTIONS LOCATION OF CONNECTION A1 FROM LEFT SIDE A2 FROM RIGHT SIDE A3 FROM BACK SIDE r O LJ tO 50 00 __ CONDENSATE DRAINAGE FROM THE REAR PIPING WITH MINIMUM INTERNAL DIAMETER OF 18 mm POWER SUPPLY FROM THE REAR CYSY WIRE 3 x 1 5 3 x 2 5 Attachment threading of the hot water heating element Attachment of the heater element to the distribution of the heating water After installing the LPHW plumbing and leading the LPHW into the element under pressure it is necessary to bleed the heater element The bleeding valve is located on the feeder pipe of the LPHW heater element To secure that the LPHW heater element works always at full heat output blowing onto the unit by a fan must be provided even when no dehumidification is being performed Therefore when using the LPHW heater element the switch of fan operation must be switched into the position of continuous operation 6 8 Mounting behind the wall to order The dehumidifiers are simply adapted also to installation behind the wall into the adjacent room In such case only two grids are visible in the swimming pool area These are the same grids which are in the basic configurat
20. upplier selects the mode of the fan according to the request of the user Periodical duty of the fan Switch of the fan operation 3 4 Control of the compressor Start up of the compressor is due to its protection delayed by 3 minutes Depending on the humidity of the environment it may take even longer for compressor to start operating Once the compressor stops operating the operation is renewed automatically atthe earliest after three minutes The user must not handle the setting element of the delay action relay 4 MAINTENANCE INSTRUCTIONS It is necessary to make sure that the suction inlet and the exhaust outlet are not covered It is forbidden to place towels or clothing items onto the exhaust outlets to dry them The unit s cover can be cleaned with standard cleaning agents using a soft cloth or a sponge If water dripping out of the unit please check the condensed water drain and make sure the pipe is not obstructed 5 SERVICING THE UNIT At least once a year it is necessary to have the unit checked and cleaned by a service specialist This is inevitable to secure a long service life of the unit We do not recommend the user to clean the interior elements of the unit as this might cause a damage to the unit The unit contains mobile elements and live elements therefore the interior parts may only be cleaned by a certified electrician trained to service refrigerating appliances 6 INSTALLATION GUIDE The unit must be ins
21. y bacteria A pipe for condensate drainage is led out at the bottom of the unit on the left This pipe is to be inserted into a sewerage pipe with the inside diameter of at least 18 mm ATTACHMENT OF THE HEATER ELEMENT TO THE DISTRIBUTION OF THE HEATING WATER THREAD G MALE OPTIONS LOCATION OF CONNECTION A1 FROM LEFT SIDE A2 FROM RIGHT SIDE A3 FROM BACK SIDE v 1 LOL o m 35 t D o 50 100 CONDENSATE DRAINAGE FROM THE REAR PIPING WITH MINIMUM INTERNAL DIAMETER OF 18 mm POWER SUPPLY FROM THE REAR CYSY WIRE 3C x 1 5 3C x 2 5 mm CONNECTIONS ARE VALID FOR MODELS DRY 300 PLASTIK AS WELL DRY 500 PLASTIK FRONT VIEW 6 6 Connection of the unit onto the mains Connection of the unit onto the mains must conform to relevant safety standards Connection reguirements Power supply 220 240V 50Hz Protection 10A DRY 300 PLASTIK or 16A DRY 500 PLASTIK by a protective switch with nominal differential drop out current not exceeding 30 mA The unit s terminal board for connection onto the electric mains is situated on the left hand side of the unit The main switch of the unit must be situated outside of the swimming pool hall The main switch of the unit must be bipolar with switch out breaking of conductors L and N An appliance for disconnecting the unit from the mains must be embedded into a firm surface The distance of contacts when swithched off must be at least 3 mm for all poles The conne

Download Pdf Manuals

image

Related Search

Related Contents

BENDIX 03-A-14B User's Manual  Braun EE 1160 User's Manual    Bedienungsanleitung Ashley 1000 - Ersatzteil  Brodit 512658 holder  APPENDIX A: USER`S MANUAL RSAP  « des lettres patentes et règlements conformes à la réalité des  Quick Start Guide - Practical Systems  5000  Stiga TRONONNEUSE SP 480 User's Manual  