User Manual - Audon Electronics
Contents
1. Settings ochedule Ping Address Save Restore Timeffone 13 16 GMT Connected Yes Date 2015 06 29 Mo Connected total 9 4 users Daylight saving Time Outlet Status Outlet Contral Outlet Mode Manual Control ID oYAdJ Jer EZS 4611 This page shows you the IP address of the outlet as well as gateway IP and DNS settings You can also view the current status of the outlet the number of users paired with the mobile app firmware and hardware versions Key Points Connected tells you whether the switch is connected to the Internet Connected Total users Shows how many users out of 4 the user limit are paired to the switch via the mobile app Outlet Status tells you whether the outlet is powered ON or OFF Outlet Control allows you to manually power the outlet ON or OFF as well as RESET Off On reboot Ver This is the current version 1D The ID number associated with the outlet This is necessary for adding the outlet to the EZoutlet mobile app Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650 SUPDOM Electronics A Settings Status Hostname err DHCP Settings IP Address Schedule Mask Ping Address Gateway Save Restore DNS Mode DNS 1 DNS 2 Outlet Mode Ping Delay After Power On 0 1440 minute s No of Resets Reset Only Time on
2. SUDOR Electronics A ezOutlet Ethernet Remote Power Switch Single UK Outlet Manual V1 0 The Single Outlet IP Switch is designed to automatically check if a network connection is online or any Ethernet device is still active Should the internet connection go down or a response from a PING request is not received the outlet is designed to automatically power cycle Users can also remotely turn on off reset the outlet via the Android iOS App or the User Interface web browser or by schedule timed on off resets Switch and check status of 1 mains power outlet via any web browser or smartphone Ethernet Interface with built in web server for use on local LAN WAN or Internet Easy setup for control via the Internet 1 x switched mains outlet via standard UK 13A socket Auto re boot power outlet on PING failure Output can switch up to 10A 250AC Network reboot function can remotely reboot the power of a PC or router at a remote site Timer Power Switch function can pre set the time schedule to turn power on off through Internet Ethernet Supports HTTP TCP IP UDP Dynamic DNS DNS Client DHCP LED indicator for LAN and power status Android and IOS Apps available Supply voltage 125 250 V AC Temperature 0 60 C Supplied with UK mains lead LAN cable and user manual Dimension 180mm x 150mm x 60mm Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk P
3. box is selected the outlet will turn on When the OFF box is selected the outlet will turn off When RESET is selected the outlet will turn the outlet OFF and then back ON Up to 6 schedule rules can be configured Time read in 24 hour format Ping Status OH Ping Setting 5 User defined or leave blank to ping default sites Schedule he Ping Address Save Restore Enter the IP address you want to send a PING request to Save Restore Status Language English OARS Settings Restart schedule system Ping Address Save Restore Reset to factory default Save settings hea No file selected settings This is where the user can manually restart the Switch reset settings to factory default save their current settings and restore settings from a previously saved file Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650 SUDOR Electronics SmartPhone Setup 1 Download the ezOutlet App from the Apple iStore https itunes apple com us app ezoutlet id5 743 76033 mt 8 or Google Play httos play google com store apps details id com megatec android outlet amp hl en 2 Connect power and a LAN cable to the ezOutlet Input ID 3 Press the ADD button once to put the ezOutlet into Add mode The LEDs will blink from Green gt Red gt Yellow for 3 mi
4. e Daylight Saving Time Username Password Confirm Password This section allows you to change the default configuration Hostname give your outlet a unique name DHCP O Select ON to allow the outlet to obtain an IP address from your router using DHCP O Select OFF will allow you to manually assign an IP address Subnet Mask and Gateway IP DNS Mode Set to Auto Acquire by default unless you have DHCP turned OFF If DHCP is OFF you must manually enter a DNS server in the fields DNS 1 andr DNS 2 When DHCP is ON and DNS Mode is Auto Acquire the outlet will automatically use the DNS se rver that your router is using Outlet Mode Select Auto Reset to have the outlet automatically reset when Internet connectio nis lost Selecting Manual Control will require user to manually reset the outlet when needed Ping Delay After Power ON This is the time the outlet will wait before it starts to ping AFTER a re set Configurable between 0 1440 minutes 1 day No of Resets This is the number of times the outlet will automatically reset when a time out is detected Configurable from 1x 10x Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650 SUPDOM Electronics Example with a 5x setting If connectivity is not restored before the 5th reset the outlet will st
5. hone 44 0 1765 677425 Fax 44 0 1765676650 SUDOR Electronics A Setup from a PC Web Browser Connect power and a LAN cable to the ezOutlet LED Indicators ED ON tis sSCSCS OFF Sid lashing _ _ _Y YO Auto Reset Is ON No Internet e Reset is OFF Red Outlet Is ON a is OFF Yellow Communication With in ve ___ Remote Server OK With Remote Server Download the Netility Software from http www audon co uk user downloads Netility zi Install and run the software Launch Web User Interface Network Search for device s LAN IP Settings 4 Netility Serial Number MAC Address IP Address 39267 1662 00 03 E 4 0D CyY CE 192 169 1 15 Fitri are Upgrade About Refresh List Found devices will be shown Click on the device and click Network Settings to change IP address settings HTTP Port add a password Click on Refresh List after any change Hardware Version EZOL W Firmware Version EZ5 4811 MAC Address 00 03 E4 OC GACE You can then click Launch Web User Interface to open your default browser Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650 SUPDOMR Electronics A Status Page Status Hostname Outlet DHCP On IP Address 192 168 1 15 DNS Mode Auto Acquire Gateway 192 168 1 1 DNS 1 192 168 1 1 MAC 00 03 EA 0D C7 CE DNS 2 139 175 55 244
6. nutes until the device is successfully added If you are unable to get the device paired within minutes you will need to start over 4 Press Add on the App and enter the ezOutlet ID Number or click QR code to use the QR code on the label Press the function button once to turn ezOutlet into Add mode LED will blink from Green gt Red gt Yellow gt 5 Click Add Android or Save iOS Up to 4 iOS or Green gt for 3 minutes and stop when Android devices can be paired to one switch successfully added If you ever need to un pair the switch from your Android iOS device go to the application select edit eer and touch the MINUS button ee TO REMOVE ALL APP USERS press and hold the ADD button on the switch for 15 seconds The YELLOW light will flash once and the switch will restart NOTE THIS WILL ALSO DO A FACTORY RESET AND CLEAR ALL SETTINGS Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650
7. op resetting after the 5 try Outlet will come back online once a connection is restored Reset Only This setting allows you to enable the ability to MANUALLY turn ON OFF or RESET the outlet even when the OUTLET MODE is set to AUTO RESET o ON The Outlet cannot be manually controlled UNLESS the OUTLET MODE is set to MANU AL CONTROL O OFF The outlet CAN be manually controlled and will STILL auto reset when it detects an Inte rnet outage Time Zone Select the time zone for the outlet location Daylight Saving Time Set the Start and End times and dates E g Username A username for logging into the Web User Interface Password A password for logging into the Web User Interface Confirm Password Enter the same password from step p Click CONFIRM button to save the changes REVERT to reset Schedule Status 1 Osu OMe OTu Owe OTh OFr OSa Schedule Ping Address 2 Osu Omo Oty Owe OTh OFr Osa save Restore i Reset hh mm off On Reset A Usu UMo UOTu Uwe UTh OFr USa hh mm Off On Reset 5 Osu Ome Omu Owe Oth Ofr Osa hh mm Off On Reset 6 Usu UMo UTu LI We UTh OFr OSa Reset Copyright C Audon Electronics Ltd 2015 Field View Wormald Green Harrogate HG3 3NJ UK www audon co uk Phone 44 0 1765 677425 Fax 44 0 1765676650 SUPDOM Electronics eens This allows the user to create scheduling rules to turn the outlet ON OFF or RESET at a certain time on the specified day s When the ON