Home

AUTO-MAN-FLEX - Automatic Manual Flex

image

Contents

1. 18 Convert to Automatic Flexion Step By Step 19 Convert to Manual Flexion Step By Step 20 Manual Flexion Function Step By Step 21 Table Elevation optional 22 Table Lateral Flex 22 Table Distraction optional ee ee 23 Installing Flex Straps 23 Table Specifications 23 iv TABLE OF CONTENTS Contents 6 Table Maintenance amp Support 24 LE AU ES ae eee Oe a Se ee ee ee ee oe 24 AMOR ee a 24 Automatic Flexion Model Only 24 Maintenance amp Care Tips 25 Control Box Fuse Replacement 26 7 Warranty 27 Return Policy 27 Safety Instructions Please study the Safety Instructions and all Operating In structions in this manual before operating your new ELITE table Failure to follow these instructions may result in injury to you or your patient Important Notice Doctors and patients must keep hands fingers and feet clear and away when the table is raised or lowered Injury could ensue Patients hands should be kept on the Arm Rest Do not allow patients to get on or off table when table is raising or lowering Patients should get on or off table when table is at it s lowest position a
2. Step 6 The table is now ready for auto matic flexion operation 20 Convert to Manual Flexion Step By Step To convert from Automatic Flexion operation to Manual Flexion operation follow these steps Step 1 Unscrew the Au tomatic Manual Conversion knob from the flexion motor bracket Step 2 Turn the knob counter clockwise until you can remove the knob Then store the knob as shown in step 2 Step 3 Store the knob you have just unscrewed on the storage location on the side of the table Step 4 The knob shown here has been set in the storage lo cation by turning clockwise Step 5 Store the auto matic flexion bar underneath the table There is a holder that the bar will clip into Step 6 Once the flexion bar has been clipped in the storage location then the table is ready for manual flexion 21 Manual Flexion Function Step By Step The following illustrates the steps used to perform manual flexion The flexion tension can be set at the rear of the table by a crank or if your table as the optional electric tension adjustment then you can use a foot pedal to adjust the tension 1 Table in locked position 2 Loosen flex lock 3 Flex down aa ie 7 Able to perform figure 8 ROM 8 Flexed down and left 9 Flexed down and right 5 du ESS
3. breakaway Once locked the cushion will not breakaway and will be ready to perform drops Breakaway Drop Cocking Handle To perform a drop follow these steps Adjust the drop tension to desired setting Turn knob clockwise to increase drop tension and counter clock wise to decrease tension Breakaway Cocking the Drop Locate the drop cocking handle and push down to cock the drop Breakaway Drop Cocked Shown here is the drop in the cocked position Breakaway Deploying the drop Once the drop has been cocked push in a downward mo tion and the drop will release Breakaway Deployed Drop The thoracic cushion will drop to the un cocked position Automatic Manual Flexion Table Control Box The Automatic amp Manual Flex table has a digital control box that is used to operate the tables Automatic flexion features There are two modes of operation Timed flexion where the flexion action will run for a period of time or manual operation where the chiropractor controls the length of the operation The control box also has a dial for selecting the flexion speed of the table Flexion Speed Dial Use to adjust the flexion speed Timer or Manual Toggle Use to select either timed operation or manual opera tion mode Flexion Duration Display The duration is read first by looking at the select units and then the time Show here i
4. 11 Tighten flex lock CTI _ i Ed RE SN mm 22 Table Elevation optional Table Lateral Flex If your table is equipped with the table elevation feature then Your table is able to flex laterally at the front and back of the you are able to control the height of the table with the tap of table a footswitch Table Lowered Table Front amp Back Flexed Right Table Raised Table Front amp Back Flexed Left Table Distraction optional Installing Flex Straps If your table is equipped with the electrical distraction then Flex straps are clipped into the loops under the cushions as you can distract the rear of the table shown in the following illustration Table Distracted d Table Not in Distracted Position 4 l Table Specifications Automatic Manual Flex Ls Weight Skidded 458 Ibs 207 kg Weight Crated 608 Ibs 275 kg Table Maintenance amp Support ELITE Chiropractic tables have been called The Work house of the Industry and while we stand behind the superior function and low maintenance needs of each model replacement parts are available should they be required Part List Minimum shipping orders apply to all parts ordered For further information please contact your ELITE Chiropractic table dealer or ELITE Manufacturing 1 800 689 4730 All Models 1 Drop springs 1 for each
5. ELITE Auto Manual Flex USER MANUAL wus 7 Auto Manual Flexion Table 22 John Street Hagersville Ontario Canada meee ET en wwwclite chirotablescom EE ELITE Manufacturing 2009 All rights Reserved 22 John Street x Hagersville ON NOA 1HO x 1 800 689 4730 fax 905 768 0822 x www elite chirotables com TABLE OF CONTENTS HI Contents Safety Instructions 1 Important Notice 1 Electrical Safety Instructions 1 2 Drops amp Cushions 2 DIS be awa eens eee ee a ee es 2 Elevate Cushion amp Ankle Rest 2 3 Headpiece 3 Standard Headpiece 3 Headpiece Adjusting the Position 4 Headpiece Optional Dual Drop How to use the Toggle Drop 5 Headpiece Optional Dual Drop How to use the Forward Motion Drop 7 HP Flex Headpiece 9 HP Flex L Headpiece 10 Installing the Paper Roller 10 4 Thoracic Breakaway 11 Thoracic Breakaway How to release the breakaway 11 Thoracic Breakaway How to use the drop 13 5 Automatic Manual Flexion Table 15 Table Overview 17 Convert to Manual Flexion Overview 18 Convert to Automatic Flexion Overview
6. When you apply upward force the headrest should in the illustrations bellow You will need this number when not move making inquires to ELITE customer support The person lifting from the back of the table should lift hold ing onto the handles as shown bellow 21 Control Box Fuse Replacement If a your table has a motor that is not functioning properly then the first step to performed is to replace the fuses in the control box Follow the steps outlined below Control Box Location Unplug your table from the wall outlet and then locate the Control Box by tilting the table as shown and laying it down on it s side Then look for the grey box that has the power cable running to it Opening the Fuse Compartment Using needle nose pliers pull the fuse box plug out of the Control Box Note You should leave the Control Box in the table as shown in the previous photo the photo s used here show a control box that has been removed from the table for clar ity of illustration Replacing the Fuses You will find two spare fuses in the plug that you just removed Replace the two fuses in the control box with the spares from the plug Once this is complete put the plug back into the control box Then stand the table upright again and plug it back into the wall outlet You can now try us ing your table again to see if it has resolved the problem NOTE If you have already used the s
7. ble Anytime a patient is entering or existing from the table power to the drive motor must be removed This is done by placing the controller s ON OFF switch into the OFF position If this switch should become damaged or faulty over the expected life span of the unit the controller must be removed from service Setting the speed control dial to zero to inhibit bed movement while not in use may cause early component failure and pres ents a safety hazard The controller s ON OFF switch must be placed into the OFF position anytime the bed movement function is not required If you perform any mechanical adjustments to the drive motor link assembly or any electrical service to motor or drive controller ALL POWER MUST BE REMOVED TO THE CONTROLLER This can be done by unplugging the drive controller from its power source and allowing a few minutes for the controller to discharge any stored power before perform ing any service work Safe Operation Explained The ELITE FLEXION CONTROL is a high quality simple to use motor speed regulator best suited where applications do not require an exact speed set point These controllers have a 5 error factored into their speed regulation This error can be magnified at the consumer s location as voltage fluctuates from area to area At the high end this will cause the drive motor to either not reach maximum RPM speed or go slightly above it all within the motor sope
8. drop 2 Steel drop ball 2 for each drop 3 Cervical drop tension rod with knob 4 Thoracic Lumbar pelvic tension rod with knob 5 Drop Tension control rod receptacle 6 Thoracic drop assembly 7 Lumbar drop assembly 8 Pelvic drop assembly 9 Headrest with cervical drop complete Headrest paper cutter assembly mah Headrest paper holder assembly ND Headrest paper roller wood Ww Drop cocking foot pedal A Clevis pins large VI Clevis pin small _ Clevis cotter pins Elevation Motor y Foot switch co Automatic Flexion Model Only 19 Flexion Handle 20 Flexion Motor 21 Digital Control Box 20 Maintenance amp Care Tips Upholstery Care Moving Your Table To prolong the life of upholstery Whisper Burkshire amp We recommend having two people move the table One leather we recommend regularly wiping cushions with a person at each end of the table The following will illustrate damp cloth containing a mild soap and water solution the proper location to lift the table Please be aware that the tables are heavy so only attempt moving the tables if you are comfortable with the weight Locating the Serial Number The person lifting from the front of the table should push the headrest Tilt Release Knob in to lock the upward motion of the The serial number is located at the back of the table as shown headrest
9. headpiece also contains a cervical drop either forward motion oriented or straight down motion Tilt Release Kigb j nn argad LESNI Sereed Ajust Kaob G eryicai Ly op Tension Adjust Paper Cutter Use the Paper Cutter to cleanly tear cut the headrest paper Tilt Release Knob To raise the headpiece to the desired angle pull up on the headpiece bracket until desired tilt is reached To lower the headpiece tilt press the Tilt release knob and move headpiece to desired angle Cushion Spread Adjust Knob Lift knob slightly and move forward or backward to achieve desired cushion spread Cervical Drop Tension Adjust Turn knob clockwise to tighten drop tension counter clockwise to decrease tension Cervical Drop Cocking Lever Push down lever to cock the drop Elevation Release Lever To lower rear headpiece cushion pull up and release To raise rear side of headpiece place hands under both sides of the face cushion base and raise to desired height 4 Headpiece Adjusting the Position The following illustrates the various position adjustments for the standard headpiece 1 Neutral Position 2 Push knob in 3 Tilt down Headpiece Optional Dual Drop How to use the Toggle Drop Our optional dual drop headpiece has both forward motion oriented and straight down motion The following illustrates how to perform a toggle drop Toggle Drop Straight Start To perform a forward motion dr
10. nd all motion ceased Never leave table unattended or in operation with patients or children present Electrical Safety Instructions If your table is equipped with an electric motor connect the table only to an outlet which is grounded and connected to a properly fused or breaker controlled circuit Make certain all electrical cords are in good condition Power cords have to be away from all pinch points or moving parts especially EA Electric Elevation Table High Low and High Low Elevation Table and Flex table Drops amp Cushions For controls on the main portion of the table headpiece excluded Drops Drop tension is adjusted by turning the drop tension adjust knob Turn clockwise to tighten or counter clockwise to loosen Tighten Push down Wih toot increases Drop Tension fo cock drop Tension adjustments are very sensitive Recommended Half turn and test for desired drop pres sure Elevate Cushion amp Ankle Rest Elevation of the cushion or ankle rest sections is achieved by placing fingers beneath cushion frame and lifting to desired angle To return cushion or ankle rest to normal horizontal position pull up on the cushion elevation release lever Elevate Cushion Clevetion Release Lever P Headpiece Elite tables can be ordered with a variety of different head rests Standard Headpiece Our standard multidirectional headpiece includes tilt eleva tion and spread The
11. nvert to Manual Flexion Over view To convert from Automatic Flexion operation to Manual Flexion operation follow these steps Automatic to Manual Conversion 1 Make sure the Control Box on off switch is switched in the off position and the table is unplugged 2 Unscrew the Automatic Manual Conversion knob and stow the handle under the table as shown in the diagram below 3 Insert the Flexion Handle Convert to Automatic Flexion Overview To convert from Manual Flexion operation to Automatic Flexion operation follow these steps Manual to Automatic Conversion 1 Grasp the Automatic Manual Conversion bar stow under the table and attach it to the motor flexion bracket as shown in the diagram above 2 Remove the flexion handle 3 Set the control box to either manual or timed flexion operation and start the flexion motion 19 Convert to Automatic Flexion Step By Step To convert from Manual Flexion operation to Automatic Flexion operation follow these steps Step 1 Remove the flexion bar from the clip under the table Step 2 Move the arm to the flexion mo tor attachment bracket Step 3 Remove the knob from the stor age location by turning counter clockwise Step 4 Now that you have the knob secure the flexion bar to the motor bracket with the knob by turning clockwise Step 5 Turn the knob clockwise until the knob secured tight
12. op follow these steps Adjust the drop tension to desired setting Turn knob clockwise to increase drop tension and counter clock wise to decrease tension Once the desired tension is set you will use the toggle drop cocking lever Toggle Drop Cocking Lever Grasp the toggle drop cocking lever Toggle Drop Cocking the Drop Pull the lever towards you to cock the drop Toggle Drop Deploying the drop Once the drop has been cocked push in a forward motion and the drop will release Toggle Drop Deployed Drop Headpiece will drop to the un cocked position Headpiece Optional Dual Drop How to use the Forward Motion Drop The following illustrates how to perform a forward motion drop Forward Motion Drop Start To perform a forward motion drop follow these steps Adjust the drop tension to desired setting Turn knob clockwise to increase drop tension and counter clock wise to decrease tension Once the desired tension is set you will use the toggle drop cocking lever Forward Motion Drop Cocking Lever Grasp the toggle drop cocking lever Forward Motion Drop Cocking the Drop Pull the lever towards you to cock the drop Forward Motion Drop Cocking Lever Next Grasp the forward motion drop cocking lever Forward Motion Drop Cocking the Drop Push the lever forward to cock the drop Forward Motion Drop Deploying the drop Once
13. pares fuses previous ly then you will have to contact ELITE to order new fuses 22 Warranty All products and parts thereof manufactured and sold by Elite Manufacturing 1180396 Ontario Inc are warranted to be free from defects in material and workmanship for a period of two years from the date of shipment If notice of claim is made within the warranty period Elite Manufacturing will repair or replace at its option the prod uct or part which is defective The customer must obtain prior authorization from Elite Manufacturing to return defective parts or to have repairs performed by non Elite personnel exclusive of authorized Elite dealers Labour charges to remove or replace defective parts are not covered by this warranty Defective conditions caused by misuse abuse acts of God accidents abnormal use or stress modifications or any other matter unrelated to Elite Manufacturing and beyond its reasonable control are not covered In no event shall Elite Manufacturing or its agents be liable for loss of use revenue or profit or for indirect consequential damages Upholstery materials and fabric are not warranted under this agreement We suggest prolong life of upholstery can be obtained by regular wiping cushions with a damp cloth containing a mild soap and water solution Return Policy ELITE MANUFACTURING Division of 1180396 Ontario Inc 1 Any order placed with us but cancelled in writin
14. ral flexion Please view the standard headpiece instructions and HP Flex instruction for operation details Lateral Flexion With the patient on the table insert the flexion handle and secure the flexion straps Then following proper procedures use the flexion handle to perform lateral flexion 11 Thoracic Breakaway Elite tables can be ordered with an optional breakaway thoracic section The Illustration shows a breakaway with optional drop in breakaway Thoracic Breakaway How to release the breakaway The following illustrates how to use the thoracic breakaway Breakaway release knob The tension for the breakaway can be adjusted by rotat ing the tension adjustment knob clockwise to increase or counter clockwise to reduce the amount of tension The breakaway release knob is shown here in the locked position Breakaway releasing the breakaway Push the breakaway release knob towards the front of the table to release the breakaway 12 Breakaway Released Once the release knob has been pushed forward the break away will be released Breakaway Testing the breakaway Shown here the breakaway in action 13 Thoracic Breakaway How to use the drop The following illustrates how to use the optional drop in the thoracic breakaway Breakaway Lock the Breakaway Push the breakaway release knob towards the back of the table to lock the
15. rational specs The same could be found at the low end of the motors RPM range This is within normal functionality for this application Table Overview Headpiece Control Box Cushion Release Standard multi direc tional headpiece Controls flexion operation Pull up on lever to return cushion to horizontal position Drop Tension Control Rotate clockwise for more tension counter clockwise to reduce tension Armrest Patient armrest 1 4 77 Distraction Foot Pedal Drop Cocking Levers Used to distract the rear section of the table optional feature Lateral Flexion Lock Tighten lever to lock rear of table in current position Can be locked in the horizontal position or during manual flexion used to lock current flexe position Elevation Foot Pedal Use the foot pedal to raise and lower the table top optonal feature Flexion Handle Release Knob pull knob to insert or remove the flexion handle Push down lever with foot to cock the drop s Flexion Handle Knee Break Use for manual flex Adjusts up 20 ion operation degrees down 10 degrees with Ries i Tension Crank Turn clockwise to increase tension counter clockwise to reduce Automatic Manual Conversion Knob For automatic flexion operation this knob must be screwed in as shown in diagram For manaul flexion operation this knob must be un screwed and the arm stowed under the tale 18 Co
16. s a selection duration of 3 minutes and 19 seconds Timed Operation Automatic Flexion 1 Switch the Timer or Manual toggle to Timer 2 Switch the On amp Off Switch to On 3 Select Mode to the desired units of time either sec onds minutes or hours Most common usage would be minutes 4 Set the amount of time using the Increase amp Decrease buttons Remember that the time displayed on the digi tal display is in the units specified by the lights beside the mode button seconds minutes or hours 5 Adjust the flexion speed of the table by turning the Speed Dial 6 Push the Start button to begin flexion and the Stop but ton to end the Flexion ELITE FLEXION CONTROL On Off Switch Starts and stops the table flexion motion Mode sec min hrs Use to set your timed flexion to be in second minutes or hours Set Timed Flexion Duration Use to increase or decrease the timed duration of the flexion operation Manual Operation Automatic Flexion Switch the Timer or Manual toggle to Manual Adjust the flexion speed of the table by turning the Speed Dial Switch the On amp Off Switch to On and the Flexion action will begin To stop the Flexion action switch the On amp Off Switch to Off Safe Operation The speed control dial of the ELITE FLEXION CONTROL is not considered a safe way to isolate the movement of the ta
17. the drop has been cocked push in a forward motion and the drop will release Forward Motion Drop Deployed Drop Headpiece will drop to the un cocked position HP Flex Headpiece Our new flexion distraction headpiece includes all the features of our standard multidirectional headpiece includ ing flexion motions long axis traction and flexion In the illustrations to follow the flex handle has been removed to simplify the diagrams In practice to use the flexion features the flex handle must be inserted into the flexion headpiece Furthermore the flex headpiece straps must also be utilized Please view the standard headpiece instructions for opera tions of standard features Long Axis Traction With the patient on the table insert the flexion handle and secure the flexion straps Then following proper procedures use the flexion handle to perform long axis traction Flexion With the patient on the table insert the flexion handle and secure the flexion straps Then following proper procedures use the flexion handle to perform flexion Elevation The headpiece can be elevated and lowered 10 HP Flex L Headpiece Installing the Paper Roller Our flexion distraction and long axis traction headpiece The following illustrates how to install the paper roller on the includes all the features of our standard multidirectional headrest headpiece and the HP Flex headpiece and also includes late
18. y P 8 prior to shipping by us will be given a full credit refund 2 Any goods that have been shipped or are in the process of shipping by us will be subject to a 20 restocking charge plus any shipping costs incurred by us for shipment out and return of such goods 3 On any returned goods we reserve the right to inspect same prior to credit refund and any damage of defects or missing items from the goods will incur charges in addition to the restocking charge and freight charges 4 If Elite has received payment from customer Elite will refund the difference to our customer after any of the above charges