Home
Stainless Steel Grated Urinal - Stoddart – Plumbing Products
Contents
1. Email sales stoddart com au Page 2 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Important Recommendations Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier if appropriate Responsibility Stoddart thoroughly inspect all products they are despatched from our factory Stoddart Manufacturing will not accept responsibility for shipping damage The Plumber is responsible to ensure that the system is installed in accordance with all specific requirements of local codes and regulations including AS 3500 If questions or complications should arise during the installation of a Stoddart product that cannot be solved using the accompanying instructions please contact our offices or local representatives Note It is the Plumbers responsibility to install this product in accordance with AS3500 Scope This product is design to be used in public places where it is required to be vandal resistant The product is manufactured to the requirements of AS1172 1 and associated reference standards Features The Grated urinal from Stoddart Manufacturing has full d
2. positions and other variables Standard Lengths of Grated Urinal 0900 1200 1500 1800 2400 2700 3000 3300 3600 3900 and 4100 in mm Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 1 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Contents NOON CONE ereraa A E A patra een R 3 Pe COMMING aE ON SS enacsocann scope mcensesecascamsnseeaviqnsaemnctenni dans EEE EAEE EERTE REAT AR ESNEA EAERI 3 RESTON OI areren e E E E EE E ATAT 3 PoU O a E E A E S 3 Referenced Australian Standards ccccccceceececeee eee ee eee ee eee eee eset AEE 1 rtrt r rE Arrr PEPE EES ES EEE EE EEE EE EEE EEE EEE ES 4 eee TT ay AUST aI ON eax A errant atc or A A EEE esr A A A A E ne canmnitnanmaneiend 5 Water SUDDIY REQUITEMENIS i iisususiriavisesiessinveannyauhiaas isinen sairaana ipa vicinus 6 TSMC Wa Slt UC TONVS aE E E pada a easuneosunsacs E ait sass eescecsense eases 6 Recommended cleaning of all stainless St el ccccccecseceeseteeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeaetesantetages 6 DO E E ee eee ee ee ee eee 6 D
3. 3441000 Web site www stoddart com au Email sales stoddart com au Page 6 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals DON T Use steel wool or metallic scrapers to remove non washable deposits Allow dirt to accumulate or to dry out and harden Use cleaners containing harsh abrasives or high bleach contents Stoddart will not accept any responsibility and our warranty will be void if bleach or acidic based cleaning agents are used to clean our stainless steel products If any of the above cleaners must be used It is imperative that the product is thoroughly washed and rinsed after cleaning with warm soapy water otherwise brown oxidization will appear on the stainless steel surface Important Never use harsh or abrasive cleaners on the product as it is stainless steel Do not use chlorinated or bleached water Warranty Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier promptly if appropriate Stoddart Manufacturing will not accept responsibility for shipping damage The Standard Terms and Conditions of Sale clearly details Standard Warranty Polic
4. AINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals g Check that the base of the urinal is not Popped up Push down to the waste to check there is still free play over the waste 4 Fix Urinal to wall a For Urinals with Tile Edge i Ensure urinal is against the wall and still in level position li drill through the tiled edge and then fix to studs in walls Please note that if the wall is not flat Z clips are not recommended for Urinals over 3 meters long The Grated Urinal is designed to stand on its legs The legs must be set on a flat surface Mortar mix or cement is not required under the urinal trough but a shovel full may be applied if required to help seat legs Check that the urinal drains Pour water into the urinal amp check it drains fully If not re check the levels and pack under feet as required Ensure waste is pressed down and the dome cover allows free drainage Water Supply Requirements All Stoddart Urinals that are coupled with a flush valve require the following e Water supply pipe must be 20mm diameter minimum e Water pressure 250kpa minimum to 500kpa maximum e Flow to the valve face must be 1 0 1 5 litres sec for effective flushing e An inline water filter should be fitted to protect the flushing valve All Stoddart Urinals that are coupled with a cistern require the following e Cistern chosen should meet relevant codes amp water efficiency standards e Flush pipe f
5. ON se seive nse aetna E ab nue saauteani esac gia aitetesnsa nine sanenansaus ons bau nec ssaneetecdeoeae wanestanens 7 UT gece eterno S EA ein dente saatanteuaidodeal ia ea nit evened E ix 7 Engauines and Complaints meee nee ne eet ee en ee eee eee 7 Automatic Flushing Devices siiiccsinvecnacas snmcdexeosteevaasrdeg dus bradeenneosatdaastanbiuontdersisi ieandeebniwideanercdvenesniuentas 8 DOOM UCC SI cccotasaataeeaa ences E E E E ens 8 SOCIO WO CV ICS oripa nE E caret tala neta Porter E E EREET E EERIE 8 DCS IN a esencs cence E N A E A L E cua merece E E E nee weiss 9 Other Auto Flushing Devices cccccssecsecueeseeceeusueceaueueueceaueueeuaeaueureeauaueerseauaueerseaueuresevaueereeasaneans 10 Galvin Engineering Urinal Flushing Device sssesssssrsrenrersrrnrsrnrrnrernnrnrnrrnrnrnnrnrnnrnrurrnrnrnernrerrnns 10 Enware Urinal Flushing device anne eee tee eee teeter nT teen nee eee kaira kaia aaa 10 Zip Urinal Flushing device agra dcudieacenenetashannaadunnedaertaunded butasusiencaat dunbianisenrdnn veateabubstian Gudneubrenneat 10 Example Grared Urinal Order ON eeskiri aE AANE AE TAE 11 Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au
6. STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals L Shaped Stainless Steel 1800 mm Stainless Steel Grated Urinal Grated Urinal Installation and Operation Manual Stainless Steel Grated Urinal This manual is for the following models of Urinals Straight Model Code Stainless Steel Grated Urinal SPPL UR G T L xXxxx Urinal Grated Top Entry Left Waste Standard Length SPPL UR G T R xxXxx Urinal Grated Top Entry Right Waste Standard Length SPPL UR G T C xxxx Urinal Grated Top Entry Centre Waste Standard Length SPPL UR G T 2 XXXX Urinal Grated Top Entry Two Wastes Standard Length SPPL UR G R L XXXX Urinal Grated Rear Entry Left Waste Standard Length SPPL UR G R R XXXX Urinal Grated Rear Entry Right Waste Standard Length SPPL UR G R C XXXX Urinal Grated Rear Entry Centre waste Standard Length SPPL UR G R 2 XXXX Urinal Grated Rear Entry Two Wastes Standard Length L Shape Model Code Stainless Steel Grated Urinal SPPL UR G L T xxxx yyyy VAR Urinal Grated L Shape Top Entry Length of each side A Grated Urinal Order Form must be completed to capture the waste positions and other variables U Shape Model Code Stainless Steel Grated Urinal SPPL UR G U T xxxx yyyy zzzz VAR Urinal Grated U Shape Top Entry Length of each side A Grated Urinal Order Form must be completed to capture the waste
7. TS Specification Installation and Operation Stainless Steel Grated Urinals Schematic xK The more stars the more water efficient iai valve WATER RATING Transformer joint government and industry program Licence No 0196 Water Consumption litres per flush per stall f 2 g Whee tamed m accordance ett Sxadard ASNZS 4400 Air bra ke For more information and to compare L i products refer to www waterrating gov au a I me SSS Flush buttons Cable with gray es dashed line lt PEPES par Valve Flue connect to oi connection connection connecton Ful Flueh hian connection Net emid HALF FULL VALVE BUTTON BUTTON WC Dual Flush Module DFM 01 Peewee 4 DFM 01 Module Fill iF hii iiai Fiii tpl obi THT FULL FLUSH TIME HALF AUTO H ingui 1de 10 Flush time adjustment Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Paqe 9 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Other Aut
8. Urinal must not hang off Z clip 2 Prepare sewer waste pipe a Cut Sewer pipe to a height to ensure that when the urinal is put into position the pipe is clear of the underside of the urinal trough You must have clearance between sewer pipe and the underside of urinal trough 15mm b Place the rubber cap supplied over the sewer and check that it can be pushed fully into position Plumber may use alternative caps or sealing methods You may have to chip the some concrete floor away from around pipe 3 Set urinal into place a Place urinal over waste and lower onto floor so that urinal support feet are level and back edges fit into Z clips b Check that the front edge of the urinal is level C Check that the top edge of the rear of the urinal is level and d Check that the top edges of the side walls are level front to back _ _ e DO NOT use sparge cover as level reference f Check that there is at least 1 100 fall from all points to the waste Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 5 of 11 STODDART Specification Installation and Operation MANUFACTURING ST
9. epth sides for superior hygiene e The urinal has a concealed vandal resistant sparge that wraps around onto the sidewalls to ensure proper wash with each flush e Stoddart grated urinal is fully supported on legs for easy installation do not fill void under trough e The unit can be set into a floor recessed so top grate is flush with finished floor level or set on floor fitted with an optional stainless steel front kick panel e Grate Is high strength slip resistant hygienic Stainless Steel Grate is hinged for cleaning access All internal corners have large radius for cleaning ease and effective drainage e Fall to waste of 1 100 ensures proper drainage e Compressed fibre cement backing provides anti drum noise suppression e Optional Freestanding end panels are available e Long units can be made modular to avoid onsite welding e Top edge can have either a returned edge or a tile edge Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 3 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Re
10. ferenced Australian Standards Markings Unit Marking to include Maker s AS 3982 1996 Name Model identification Urinal Materials Stainless Steel AS 3982 1996 clauses clauses Shall comply with the applicable AS 3982 1996 clauses Flushing Valves po MP5 2 Speec 2 Drainage AS 500 Installations Warranty Installation AS3500 instructions shall be provided by the manufacture Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 4 of 11 STODDART Specification Installation and Operation Stainless Steel Grated Urinals STAINLESS PLUMBING PRODUCTS Grated Urinal Installation A qualified plumber must install all Urinals Stoddart can deliver urinals to site and where required can site weld large urinals together inside the room l Preparation a Place the urinal upright on a level floor and measure the distance from the underside of the trough at the waste to floor b Mark the floor where the urinal legs will be positioned amp ensure surface is flat and level C Position amp fix Z clips to wall for returned edge type urinals Z clip must hold top edges of urinal to wall but
11. nstallation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Automatic Flushing Devices There are many brands of automatic urinal flushing devices available The following is one commonly used example It is critical that the flushing valve and the flush pipe allow the water to flow with sufficient velocity to fill the sparge pipe and provide full washing of the back and sides of the urinal Sanitron Auto Flush The Sanitron Auto Urinal Flush is a mains powered passive infrared detection system that automatically flushes stainless steel urinals It comes complete with sensor control module 20mm solenoid valve with air brake power pack and pipe size adaptor UNG TEMEA Setting up Device Sensor Positioning Install the sensor with CS 1 or CS 2 the arrow on the sticker Sensor pointing towards the urinal A ceiling Equal Equal ceiling fe Cd Cd Urinal lh B Elevation 2 4m A g g alll Section Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 8 of 11 STODDART MANUFACTURING STAINLESS PLUMBING PRODUC
12. o Flushing Devices Galvin Engineering Urinal Flushing Device Refer to www Galvinengineering com Pimm Fha Motion l Sensor ae SN aa Transtormer Isolating J r Ball Valve 7 Y Line ma solenoid ON Strainer Valve ooa _ Kf On A ig m a E OC q k _ i Yop Air Disconnection 40mm Flush Pipe Minimum Length 1 Metre ee Coupling _ Urin gl Sen Maximum 3 Metres Enware Urinal Flushing device Refer to http www enware com au estore category aspx id 2878 Zip Urinal Flushing device www zipindustries com media 123689 zip flushmaster an or urinal flush system spec sheet may Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 149 Jackson Road Sunnybank Hills Qld Distributed by Revision Date 24 11 2010 Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 10 of 11 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Grated Urinals Example Grated Urinal Order Form RiGee OPREUR Zy 00O PI lete all the it in the table below dae Om pie a a eae SPPL Standard Plumbing Product Cross out the drawing that doesn t apply UR G Urinal Grated Z Top entry water supply Waste at Left End Meas
13. rom cistern to urinal should be 40mm NB e Flush pipe should be as straight as possible Cleaning I nstructions Recommended cleaning of all stainless steel Using a soft cloth that has been dampened with warm soapy water best cleans exterior or interior Stainless steel Rinsing with clean water and drying with a soft cloth should follow this Do not use steel wool coarse fabrics or abrasive polishing solutions as they will permanently damage the finish Light rust marks or stains may be effectively removed by moistening a soft cloth with 10 solution of sodium citrate sprinkling on a light layer of whiting and rubbing in the direction of the grain Thorough rinsing and drying with a soft cloth should follow this If desired the stainless steel may be waxed with a good quality non abrasive liquid or paste automobile wax Remember these does and don ts DO Wash regularly with soapy water or detergent using a clean cloth and if necessary a soft bristle brush Remove non washable deposits using an approved cleaner Clean in one direction only along the original polish lines Rinse well with clean water and wipe dry Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 3
14. ured from Left End Dim B Rear entry water supply Din A y L Left waste R Right Waste C Centre Waste 2 2 wastes 1 each end XXXX lengths e Std lengths 900 1200 1500 1800 2400 2700 3000 3300 3600 3900 4100 610 Waste at Right End Measured from Right End Dim Br DimiA Dimension mm Code Letter Overall Length Dim A eS Wase Postion fom Letem Waste Postion rom Right End Dm Waste Position off Rear Wall Dim C ee EDGE DETAILS Wase Diver Dim 50765757100 Eige 1 Dersi T Ted oFR Retumed Feige 4 De T Ted or Retunes Edge 5 Detail T Tiled or R Returned ee Free Standing End Tielet R ighe E Include SS Kick Plate Yes No Water Inlet Type T Top R i Quantity a Tiled Edge Water Inlet Top Entry size 25 32 38 mm Rear Entry size is always 25mm For Multiple or custom Water Inlet Positions sketch positions on plan and dimensions from ends mm Approved by Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 11 of 11
15. y Plumbing Products offer additional conditions as follows e Warranty on materials and labour is limited to 12 months from date of installation e The Warranty does not cover damage caused by abuse misuse or improper application or improper installation e Warranty Claims must be submitted in writing to Stoddart Manufacturing within 14 days of observation of fault e l tems may be returned to Stoddart s Factory by the Customer for warranty inspection For valid warranty claims Stoddart will repair or replacement the item and return it to the Customer promptly e For installed products Photos must accompany the Warranty Claim for effective consideration e lf a site visit is required to conduct warranty repairs such work will be carried out during normal business hours e g 8am to 5pm Mon to Fri Enquiries and Complaints Should you have any queries or complaints please contact the Stoddart Plumbing Division on 07 33455011 or 0412 259 820 Luke Simpson 07 33440929 Ed Van Daalen 07 33440979 Anton Young Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 24 11 2010 149 Jackson Road Sunnybank Hills Qld Printed date 24 11 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 7 of 11 STODDART Specification I
Download Pdf Manuals
Related Search
Related Contents
AMRESCO Ready PCR Mix, 2X (N806 WHA 900 - Agmatel User Manual Allô propreté Bose SoundTrue in-ear Manual del usuario de 2003 FOX FORX 1 - Casa Veerkamp Folheto de modelo Satellite C660-1HE POWER WALKER VI 400/600/800 Samsung NX10 User Manual Copyright © All rights reserved.
Failed to retrieve file