Home

ML-IP - RADProductsOnline

image

Contents

1. 3 4 System Level RADview SC TDMolIP ML IP User s Manual Chapter 3 Configuration Management zw 50 50 50 100 Channel Associated Signaling Figure 3 5 Channel Associated Signaling Polling the Agent gt To poll the agent e Configuration gt Poll Agent The agent is polled Maintaining Manager List The Manager List command enables you to establish the actual link between the selected Megaplex device and the manager Note You can define up to ten managers for each host gt To display the manager list e Options gt Manager List The Manager List appears System Level 3 5 Chapter 3 Configuration Management RADview SC TDMolIP ML IP User s Manual 172 17 152 49 Manager List D xj Host No Manager IP Address 172 17 150 135 172 17 150 175 0 0 0 0 Change Remove Close Refresh Ready m Figure 3 6 Manager List Table 3 3 Manager List Parameters Parameter Possible Values Remarks Host No 1 10 Manager IP Address IP address of the Network Management System gt To change an entry in the manager list 1 Select an entry in the Manager List and click Change The Change Manager dialog box appears x Host No 4 Manager IP Address fi 72 47 150 135 Set Cancel r pm Figure 3 7 Change Manager 2 Change the Manager IP Address 3 Click lt Set gt to implement the changes gt To remove an entry from
2. Internal Port Parameter Possible Values Remarks Slot IO slot of ML IP card Card Type ML IP Port Selected port Internal 1 Internal 2 Connect No Yes CAS Enable Enables CAS Routing Protocol Enable checked Disable unchecked None RIP2 Proprietary RIP OOS Signal State of the signaling bits when the link is in out of service OOS state Forced Idle Signaling bits A and B are idle when the link is in out of service state In addition if the line type is ESF signaling bits C and D are also idle Forced Busy Signaling bits A and B are busy when the link is in out of service state In addition if the line type is ESF signaling bits C and D are also busy Busy Idle Signaling bits A and B are busy for 2 5 seconds then become idle until the out of service state ends In addition if the line type is ESF signaling bits C and D are idle for 2 5 seconds before switching to busy state Idle Busy Signaling bits A and B are idle for 2 5 seconds then become busy until the out of service state ends In addition if the line type is ESF signaling bits C and D are busy for 2 5 seconds before switching to idle state Signaling Profile 1 2 3 4 5 IP Address IP Address IP Mask IP Mask Echo Canceler Off On 3 10 Port Level RADview SC TDMolP ML IP User s Manual RADview SC TDMolIP ML IP User s Manual Chapter 3 Configuration Management Configuring Bundles gt To configure bundles for an interna
3. A Disable Enable Traffic Priority Indicates the traffic priority of this port NA Low High Note When Auto Negotiation is disabled and Max Capability Advertised is different from the capabilities of the LAN i e Max Capability 100Bas T full duplex while LAN works in 10BaseT half duplex NMS will disconnect Internal Port Focusing on the interface name level allows you to access the interface menus 172 17 152 49 Connected loj xl Configuration Fault Diagnostics statist ptions Help Slot Interface Name Interface Type System External 1 External 2 External 3 Internal 2 Figure 3 10 Element Manager Internal Port in Focus RADview for Megaplex allows you to monitor and configure the following port level management options Configuring Interface Parameters gt To display interface parameters for the internal port 1 Click an internal port 2 Configuration gt Interface Parameters The Interface Parameters dialog box appears Port Level 3 9 Chapter 3 Configuration Management 172 17 152 49 Interface Parameters Slot 10 5 Card Type ML IP Port Internal 1 Connect Yes CAS Enable E Routing Protocol None OOS Signal 2 Signaling Profile 2 IP Address 172 17 152 32 IP Mask 255 255 255 0 Set Cancel Refresh Ready 7 Figure 3 11 Interface Parameters Dialog Box Internal Port Table 3 5 Interface Parameters
4. RADview SC TDMolP Network Management System Service Center for TDMoIP Applications ML IP 1994 2005 RAD Data Communications Publication 01 05 Contents Chapter 1 Introduction 1 1 Overview or RADVIBW FCAPS Model espere riore VeDHEIN PROS PHARA D HEROUM a ER Ea MS 1 1 142 System Level Operations rssikon es a ania aire n rU dn denne rss 1 1 Element Manager WihdOW i ce eerte ttt i Reese ede E to rr ee ee HERR URS 1 1 Ue Port Leyel Operations nC 1 3 Chapter 2 Fault Configuration 2A System Level ew 2 1 Viewing Sanity t Deck Res US oe iiciin iiaia i aiaiai 2 1 Chapter 3 Configuration Management BAT System Level c rae a a R a 3 1 Configuring System Information esses eene 3 1 Configuring Bundles e 3 2 Displaying Time Slot Assignments atur cund acier vas don HERR LUN CAN DURAM R VOULU GER dE 3 3 Polling the ASE ES rr eee eN A el 3 5 Maintaining Manager EISE sect n tcu c e e t t tke t E E Reis 3 5 3 2 cc dr T 3 7 Exterival ORE E E O N TAT E AT 3 7 Inema Por enra a EE LE 3 9 1 1 Element Manager UMESIP aside c ae esi ei iS beide eeiam a E EON E N Pa NR eia FRU 1 2 1 2 Element Manager e Internal Port in FOGU ecc bus coiere Eier icto eR rr ta aai ae tesi c ibs 1 3 2 1 Sanity Check Error List csscis sis aatnetaiastanesaiiueisnstanelasselauaisdaiuuuetaasetegtatiuuteatnentuasnenyans 2 1 3 1 System Information Dialog BOX oe actaiaaiie
5. e ontanntdeldtandcantamcteiey e LM RED DR SPI DUE 3 1 25 Bundle Connection Table desistit eti ta seien ernis a essit Gan a e esso est 3 2 3 3 Time Slot ASSIBDETIETNE cedente tad acti dnb detras teta Ld ia esed dd teeta 3 4 34s Select ML PO EC M 3 4 3 5 Channel Associated Smgnaling isset otio Um Eni s eiGd a equ t iia Ru e beu US ENDE OD MR UUE 3 5 3 0 Manager BI X 3 6 3 7 Change Ma ager sssi tatus aeneis dnd Movie UN aeaa an iNES 3 6 3 8 Element Manager External Port in FOCUS adu sien dint oat adi eats due buges 3 7 3 9 Interface Parameters Dialog Box External Port eos 3 8 3 10 Element Manager Internal Port in FOCUS sssesassactonsasnetssacisiaaabioiaesdineiseesiatinaadetesanss 3 9 3 11 Interface Parameters Dialog Box Internal Port nte 3 10 3 12 Bundle Configuration Table Port Eevel iae ertet ead reta es dran itd rad uad 3 11 RADview SC TDMoIP ML IP User s Manual Table of Contents Tels System Management Options ig s d xd DR EERARA REEF innne s E EEEE EES EEAS 1 2 1 2 Internal Port Level Management ODDO d Uca iua decode epar deii Pris ena dd da 1 3 1 3 External Port Level Management Options s qossosbesesvtia brc er ctr ckineiu tbe buxp dime ui De es d 1 3 2 1 Sanity Check Error P rameters od baeo enata Anar Dep d E MR Ded RUM NE 2 2 3 1 System Ifor Mator o ecce br d M el RR Db ot ep eia IR Ud dn ca E EE EA 3 2 3 2 Bundle Connection Parameters 5 sau ovvivis bna isidepa qaiitui inpia Uie n
6. esired Enter path and filename and click OK 2 2 System Level Chapter 3 Configuration Management This section describes the different configuration operations for system and port levels 3 1 System Level At system level you can e Configure system information e Configure bundles e View timeslot assignments e Poll the agent e Configure managers Configuring System Information gt To set system information for the selected Megaplex device 1 Configuration gt System Info The System Information dialog box appears Figure 3 1 2 Enter the required settings You can change the Name Contact and Location fields 3 Click lt Set gt to implement the changes 172 17 152 49 System Information 1 x Description MP2100 SW Ver 9 11 Object ID radMP 2100 Name Mmea Contact Name ofcontactperson 1 Location fne location offhisdevce System Up Time 14 days 19 55 22 Number of Interfaces 2 Set Cancel Refresh Ready a Figure 3 1 System Information Dialog Box System Level 3 1 Chapter 3 Configuration Management RADview SC TDMolIP ML IP User s Manual Table 3 1 System Information Parameter Possible Values Remarks Description HW and SW information for the device Object ID Object ID Name User specified name Contact User specified name of contact person Location User specified location of Megaplex System Up Time Period of time s
7. ger The Element Manager dialog box Figure 1 1 appears allowing you to configure any of the elements listed Element Manager Window The Element Manager window allows you to configure the ML IP at different levels e System e Port Focusing on the interface name level allows you to access the interface s menus System Level Operations 1 1 Chapter 1 Introduction 172 17 152 49 Connected Configuration Fault L RADview SC TDMoIP ML IP User s Manual Options Help External 1 Interface Name Interface Type System MP 2100 External 2 External 3 Internal 1 lInternal 2 Figure 1 1 Element Manager ML IP The ML IP element manager allows you to monitor and configure the following system level management options Tasks Configuration Viewing system information Viewing and removing bundles Viewing timeslots Polling the agent Tasks Fault Viewing list of errors from last sanity check Tasks Options Establishing link between Megaplex and manager Table 1 1 System Management Options Dialog Box and Parameter Location System Information dialog box See Configuring System Information Bundle ConnectionTable See Configuring Bundles Timeslot Assignment dialog box See Displaying Time Slot Assignments See Polling the Agent Dialog Box and Parameter Location Sanity Check Errors List See Displaying Sanity Check Results Dialog Box and Pa
8. ircuits consisting of two IPmux 1 units It is not available for circuits with one IPmux 1 at one end and an IPmux 4 or Pmux 16 at the other end TDM Bytes in Frame E1 T1 48 1440 steps of 48 Note List of values differs for different interfaces E3 T3 240 1440 steps of 48 VLAN Tagging Yes checked No unchecked VLAN ID 1 4094 VLAN Priority 0 7 Rdn Bundle NA Number of redundant bundle Exit Port External 1 External 2 Auto gt To remove an entry from the Bundle Connection Table Select a row in the Bundle Connection Table and click Remove Displaying Time Slot Assignments gt To view time slot assignments 1 Configuration gt TS Assignment The Select ML Port dialog box appears System Level 3 3 Chapter 3 Configuration Management RADview SC TDMOoIP ML IP User s Manual 172 17 152 49 Select ML Port jo 5 JMLIP Internal 2 Figure 3 3 Time Slot Assignment 2 Select the desired ML IP port and click TS Assignment gt The Time Slot Assignment dialog box appears zw 5 50 50 100 TS Assignment sre sit Pot rmesit Direction TS Type 2J0 2 Edema 2 NA Both voice 3 0 2 Edema 3 NA Both voice 4J0 2 Edema F4 NA Both voice 5JO 3 Eterna NA Both Voie Figure 3 4 Select ML Port 3 Select the desired timeslot and click CAS The Channel Associated dialog box appears
9. k RASNON HRS MM ERR MS 3 2 3 3 Manager List Paramete ses rere rs a e eE on wee EEE ation wenmueNaaIN ano 3 4 Interface P rameters T vanmavan EEEE EE KEI 3 8 3 5 Interface Parameters Internal Port tne trait oveedadsvindoudsnidevaannvionavan 3 10 3 6 Bundle Configuration Table Parameters Internal Port 3 12 ii RADview SC TDMoIP ML IP User s Manual List of Tables Chapter 1 Introduction 1 1 Overview of RADview FCAPS Model RADview provides a complete solution for monitoring and controlling ML IP The RADview solutions conform to ITU T Telecommunication Management Network TMN recommendations for SNMP management systems known as the FCAPS model e Fault management detects and correlates fault in network devices isolates faults and initiates recovery actions e Configuration management tracks configuration changes configures installs and distributes software and configuration files across the network e Accounting management collects accounting data and generates network usage reports e Performance management continuously monitors network performance QoS CoS and resource allocation e Security management controls and restricts access to network resources 1 2 System Level Operations The element manager allows you to configure the device parameters gt To configure ML IP via the element manager e Select the node in the Service Center map and from the Configuration menu select Element Mana
10. k blue box while unassigned time slots are marked with a gray box A T1 port has 24 timeslots that can be assigned to a bundle an E1 port has 31 without MF or 30 with MF Timeslots already selected as part of another bundle are colored dark blue Available Timeslots are colored gray To select an available timeslot 1 Select a bundle from the Bundle Configuration Table and click Edit 2 Click the square beneath the TS number Selected timeslots appear yellow 3 Click Apply To select all available timeslots for the selected bundle e Click Select All To remove all selected timeslots from the selected bundle e Click Clear All gt You cannot edit a bundle that has already been used to define a connection in the Bundle Connection Table Figure 3 2 To edit such a bundle first delete the bundle from the Bundle Connection Table Configuring Bundles and then return to the Bundle Table to select new parameters Port Level
11. l port 1 Click an internal port 2 Configuration gt Bundles The Bundle Table appears 172 17 152 49 Bundles X Slot 10 5 Card Type ML IP Port Internal 1 Bundle No Bundle Name Empty Bundle Bundle Status 1 2 3 4 5 5 T 8 9 1 111 12 13 14 15 16 1 18 19 20 21 22 BA BHF 29 29 DiHn O oem see st ai Close Refresh Rea S Tm Figure 3 12 Bundle Configuration Table Port Level Bundles are groups of timeslots The Bundle Table displays the details of each bundle in the upper section of the table and a representation of each timeslot with the bundle assigned to it in the lower section of the table Each bundle can be assigned to multiple timeslots but each timeslot can only have one bundle assigned to it Port Level 3 11 Chapter 3 Configuration Management RADview SC TDMoIP ML IP User s Manual Table 3 6 Bundle Configuration Table Parameters Internal Port Parameter Possible Values Remarks Slot IO slot of ML IP card Card Type ML IP Port Selected port Internal 1 Internal 2 Bundle No Bundle Number Bundle Name Empty Bundle Bundle Status Time Slots 3 12 Note Name of the selected bundle When checked indicates the bundle has not been assigned to any TSs time slots Up Down Remote Fail Local Fail Unavailable Validation Fail The timeslots and the bundles assigned to them Timeslots with bundles assigned to them are marked with a dar
12. o Ring Mode Disable Protected IP Enable INA Traffic Priority Low close Retresh Ready ry Figure 3 9 Interface Parameters Dialog Box External Port Table 3 4 Interface Parameters Parameter Possible Values Remarks Slot IO slot of ML IP card Card Type ML IP Port Selected port External 1 External 3 Auto Negotiation Enable Disable Max Capability Defines the maximum capabilities of the interface Advertised 10BASE T half duplex mode 10BASE T full duplex mode 100BASE TX half duplex mode 100BASE TX full duplex mode Only applicable when autonegotiation is enabled Default Type 10BASE T half duplex mode 10BASE T full duplex mode 10BASE TX half duplex mode 10BASE TX full duplex mode Only applicable when autonegotiation is disabled Mng VLAN Tagging Enable VLAN tagging Yes No Mng VLAN ID VLAN ID 1 4094 This field exist only when Mng VLAN Tagging is Yes This field does not exist for external 3 port Mng VLAN Priority Ring Mode 3 8 Port Level 0 7 This field exist only when Mng VLAN Tagging is Yes This field does not exist for external 3 port Indicates If Ring Mode is enabled or not Enable Disable RADview SC TDMolIP ML IP User s Manual Chapter 3 Configuration Management Table 3 4 Interface Parameters Cont Parameter Possible Values Remarks Protected IP Enable Indicates whether a list of protected IP addresses is enabled or not N
13. rameter Location Manager List See Maintaining Manager List 1 2 System Level Operations Path Configuration we System Info Configuration gt Bundle Connection Table Configuration we S Assignment Configuration Poll Agent Path Fault Sanity Check Errors Path Options gt Manager List RADview SC TDMolIP ML IP User s Manual Chapter 1 Introduction 1 3 Port Level Operations Focusing on the interface name level allows you to access the interface s menus 172 17 152 49 Connected E inl x Configuration Tut at St pt Help Interface Name System External 1 External 2 External 3 Internal 1 Internal 2 Figure 1 2 Element Manager Internal Port in Focus RADview for Megaplex allows you to monitor and configure the following port level management options Table 1 2 Internal Port Level Management Options Tasks Configuration Dialog Box and Parameter Location Path Setting internal port Parameters dialog box Configuration parameters See Configuring Interface Parameters weParameters Configuring bundles Bundle dialog box Configuration See Configuring Bundles Bundles Table 1 3 External Port Level Management Options Tasks Configuration Dialog Box and Parameter Location Path Displaying interface Parameters dialog box Configuration parameters See Viewing Interface Parameters we Interface Parameters Port Level Operations 1 3 Chapter 1 Int
14. roduction RADview SC TDMolIP ML IP User s Manual 1 4 Port Level Operations Chapter 2 Fault Configuration This section describes Fault Configuration operation for system and port levels 2 1 System Level At system level you can View Sanity Check Results Viewing Sanity Check Results gt To view the latest sanity check results From the Fault menu select Sanity Check Errors The Sanity Check Error List appears displaying a list of errors and or warnings detected during the latest sanity check If the latest sanity check detected no errors the message NO SANITY ERRORS appears 172 17 152 49 Sanity Check Error List Card Type Port VanTS Description ML IP IN1 TS01 n 443 ILLEGAL TS BND ASSIGNMENT Print Save Close Refresh Ready m Figure 2 1 Sanity Check Error List System Level 2 1 Chapter 2 Fault Configuration RADview SC TDMoIP ML IP User s Manual Table 2 1 Sanity Check Error Parameters Parameter Possible Values Remarks Slot Slot in which the error was detected Card Type Type of card in which the error was detected Port Port in which the error was detected VAR TS Timeslot in which the error was detected Description Brief description of the error Save Click Save to save the Sanity Check Errors List in a file The Save dialog box appears with the default output file name output txt This file name can be changed if d
15. the Manager List e Select the desired entry in the Manager List and click Remove A message appears warning about possible disconnection of the manager during work 3 6 System Level RADview SC TDMolIP ML IP User s Manual Chapter 3 Configuration Management 3 2 Port Level The ML IP element manager allows you to monitor and configure either External or Internal port level management options The functionality for both types of ports is different and is explained below External Port Focusing on the interface name level allows you to access the interface s menus 172 17 152 49 Connected Configuration Fault Diagnostics Statistics Options Help Slot Interface Name Interface Type MP 2100 System Eterna eee External 2 ETH External 3 ETH Internal 1 E1 Internal 2 E1 Figure 3 8 Element Manager External Port in Focus Viewing Interface Parameters gt To view interface parameters for the external port 1 Click the external port 2 Configuration gt Interface Parameters The Interface Parameters dialog box appears Port Level 3 7 Chapter 3 Configuration Management RADview SC TDMolIP ML IP User s Manual 172 17 152 49 Interface Parameters xl Slot 10 5 Card Type IML IP Port External 1 Auto Negotiation Disable Max Capability Advertised 100BASE TX Full Duplex Mode Default Type 1 DOBASE TX Full Duplex Mode Mng VLAN Tagging N
16. ystem has been on Number of Interfaces Number of interfaces in Megaplex Configuring Bundles gt To view the bundle connection table e Configuration gt Bundle Connection Table The Bundle Connection Table appears Note The Bundle Connection Table is used by all the different Megaplex products Not all parameters are relevant to ML IP 172 17 152 49 Bundle Connection Table Dest Jitter Buffer ete op Bundle tens of usec Bundle Name Remove Close Refresh Figure 3 2 Bundle Connection Table Table 3 2 Bundle Connection Parameters Parameter Possible Values Remarks Slot No Slot to be configured 1 1 12 Channel No Bundle No 1 120 Bundle Name Bundle name for selected channel Table displays one bundle name per line Admin Status Connected Disconnected frames will not be sent from this channel Oper Status Up Remote Fail Local Fail 3 2 System Level RADview SC TDMoIP ML IP User s Manual Chapter 3 Configuration Management Table 3 2 Bundle Connection Parameters Cont Parameter Possible Values Remarks Dest Name Logical name or IP address of the destination mux Next Hop Indicates IP address to which the Ethernet frame will be sent when the Dest Name IP is not in the device subnet Dest Bundle Bundle number in the destination mux 1 2016 Jitter Buffer tens of E1 0 3 3200 seconds T1 0 3 2400 TOS 0 255 Note TOS configuration is enabled only for c