DSP-13 User Manual
Contents
1. When two sensors are used they must be connected in series to the master not connected in parallel It is advised that you tape down the sensor on the surface in the approximate location that you plan to install at Connect it to the master and verify that detection zone is where you want it to be and that moving objects such as a gate are not picked up by the sensor You may need to adjust the sensitivity and the placement of the sensor to get the desired detection zone Be careful to insure that during your testing that vehicle tires do not run over the sensor itself while it is taped down This will destroy the sensor Type of Wire Used The sensors are provided with 75 feet of lead in cable and this is usually sufficient for most installations However if additional lead in cable is needed a two conductor twisted pair cable should be used This cable should have a jacket rated for wet locations as most conduits will eventually fill with water at some point The gauge of the wires in the lead in cable to use depends on distance in cable feet from the sensor to the detector The gauge of the wires within the cable can be 20AWG as long as the detector is within 100 feet of the sensor in cable distance For 100 to 200 feet use at least 18AWG wires At greater than 200 feet use a 16AWG wires at a minimum DSP 13 User Manual Page 10 of 15 DSP13_MAN_B Installation Practices The sensors can be installed in several different ways depending on th
2. if a vehicle arrives when the unit is without power when power is restored the TRIAD system will show detect if there is now a vehicle in the detection zone DSP 13 User Manual Page 3 of 15 DSP13_MAN_B 3 Technical Data Functional Data Sensitivity Pulse Output Response Time Vehicle Hold Time Electrical Data DSP 13M Operating Voltage DSP 13M Operating Current DSP 13M Output Rating Maximum Number of Sensors Sensor to Sensor Proximity Environmental Data Operating Temperature Storage Temperature Humidity DSP 13 User Manual Ten sensitivities selectable for presence or pulse modes of operation Level 5 should be sufficient for most applications 250 milliseconds Activation 15 milliseconds minimum 55 milliseconds maximum Deactivation 15 milliseconds minimum 135 milliseconds maximum Indefinite depending on environmental noise conditions 8 volts to 30 volts DC 60 milliamps maximum and includes all current used by the sensors The output is an open collector output rated for sinking up to 50 milliamps It is not an isolated output and is referenced to pin 10 Common of the DSP 13M A DSP 13M Master can support up to two DSP 13S Sensors connected in series The sensors are passive measurement devices and as such will not interfere with other sensors at any distance 35 F to 165 F 37 C to 74 C 40 F to 176 F 40 C to 80 C Up to 95 relative humidity non
3. DSP 13 Tri Axis Detection TRIAD System Diablo Controls Inc Copyright O 2014 Document DSP13_MAN_B Released October 8 2014 Pros Who Know Trust Diablo 1 Contents Zas NOA NN ea 3 e A ST re Ce 4 Fone onai ata stcoccatncctcek a seniacadoonasansaatacnese inate E N 4 Electrica Data a 4 Environmental Data ia ica 4 Mechanical Dr lane acces boa ld aaa ede aaah le telat eee ate catalase ci 5 AS Features AIG FUNCUONS hores A io Sere 7 Presence D CLEC EON ta o a E 7 Pabe Detecta 7 SINS HEY naipes 7 Palle sales F all SC CUT iaa 7 A NIN 7 A A 8 YN E 8 NCIC ATOMS A E o 5 un Sols SOGiet heel ike ena ha ing GS ol eho eeu ince aie el aes 8 Sa A A O O ee ccudsaaadeneeawaaneding 10 Detector IAStalMs ON dl oiouadia 10 Sensor IAS dd c n 10 Bs CoOnneura MON AAA A AA E iia 12 Sens IVY A A A O 12 DIPS WINS tai 12 An E on y A 13 Es NROUDIOSHOOUINS ri ada 14 NO POWELL os dida 14 Power LED SIOWIVFSS NINE cuidada 14 Power LED Shows Two Quick Flashes Once Every Two SecondS ssssseseeseserrrserrerssrrresrreresresssrereserresereresreresse 14 Detect LED Flashes Quick Size aoalida 14 Detect LED Intermittently Comes On Stays On Without a Vehicle Present cccccccccnnnnncccnnnninnnanananinananananananos 15 Detect LED Will Not Come On With a Vehicle Present ooccccconoccnnonnnccnnonnnccnnnnnocononacononononnnonaronnnnnnconononanonnnnos 15 DSP 13 User Manual Page 2 of 15 DSP13_MAN_B 2 Introduction T
4. ESET When the detector is reset a reset occurs automatically at power up the LED will turn off for 200 milliseconds on for 200 milliseconds off for 200 milliseconds and then resume its normal display PRIOR FAILURE The detector is equipped with the ability to remember prior faults that have occurred since the last power interruption or reset The LED will turn off for 100 milliseconds on for 100 milliseconds off for 100 milliseconds on for 1700 milliseconds and then repeat the sequence until power is cycled or the is detector reset NORMAL The LED is always on when the detector is in its normal state of operation with no prior failure in memory DETECTOR RESET OCCURS Detector Reset Le20ms H 100ms Prior Failure Se a Normal Operation DSP 13 User Manual Page 8 of 15 DSP13_ MAN _B Detect LED The red Detect LED is used to display the status of detection zone and a pending change of sensitivity There are several different statuses that can be displayed on this LED RESET SENSITIVITY CHANGE DETECTION OCCUPANCY 1st Vehicle in Detection Zone 2nd Vehicle in Detection Zone Detect LED Presence Detect LED Pulse DSP 13 User Manual When the detector is reset a reset occurs automatically at power up the LED will turn off for 200 milliseconds on for 200 milliseconds off for 200 milliseconds and then resume its normal display When the sensitivity setting is changed the detect
5. LED will begin flashing at a 5 Hz rate 100 milliseconds on 100 milliseconds off This indicates that the reset switch must be pressed to send the new sensitivity setting to the sensor and stop the flashing Returning the sensitivity to the original setting will also stop the flashing When the detector is in presence mode the LED will be on while a vehicle is in the detection zone In the pulse mode the LED will turn on for 250 milliseconds with the output off for 250 milliseconds and then show the occupancy display until the vehicle exits When the detector is operating in the pulse mode of operation and the detection zone is currently is occupied the LED will be turned on to a dimmer level than normal and the LED will be flashed at a very fast rate that will make it look like it is flickering This display is meant to be easily distinguishable from the normal on display With this additional display mode the pulse mode of operation can easily be monitored for correct operation A look at the following figure will show how this occupancy indication is used to provide additional information during pulse mode operation In the figure the occupancy display is shown as the gray shaded area 250ms Page 9 of 15 DSP13_MAN_B 5 Installation Detector Installation Location The detector should be installed in a weatherproof location that is near the detection zone Ideally a technician should be able to see the detection
6. When configured for pulse mode the output will always operate in the fail secure mode OFF the fail safe mode of operation is selected ON the fail secure mode of operation is selected Pin Out There is only one version of the DSP13M The table below shows the pin out for the detector 4 Noconnection 6 Nocomnection 8 Detectoutput 9 Power 12 to 24 volts DC DSP 13 User Manual Page 13 of 15 DSP13_MAN_B 7 Troubleshooting No Power LED Use a meter to measure the voltage applied to the detector The voltage must be DC and above 8 volts If the correct voltage is applied and the power LED is not on replace the detector Power LED Slowly Flashing This flash rate indicates that the sensors cannot be seen by the master This will happen if the applied DC voltage is below about 6 5 volts If the voltage is above the required 8 volts for normal operation either the wiring to the sensor has failed or the sensor itself has failed Check and tighten all connections and splices in the sensor wiring path Connect a known good sensor to the master If the slow flashing stops and is replaced with two quick flashes every two seconds or just a solid power LED then the issue is with the sensor or its wiring If there are two sensors connected to the master separate them and connect them one at a time to the master to determine if both are failed or just one of them Once isolated replace the defective sensor If the
7. ation Fail safe operation is only available when a valid input voltage is applied to the detector When configured for pulse output the detector will always operate in the fail secure mode DSP 13 User Manual Page 7 of 15 DSP13_ MAN _B Fail Secure When the detector is in the presence mode of operation and a sensor failure is detected the output will stay deactivated during the failure In gate applications this feature is used to keep the gate closed if a sensor fails It should be noted that a power failure will always result in a fail secure operation When configured for pulse output the detector will always operate in the fail secure mode Detector Reset When the reset switch is pressed the master will send a reset command to all connected sensors If a prior sensor fault was being displayed it will be cleared Care should be taken to insure that the detector is not reset while any vehicles or objects are in or near the detection zone These vehicles or objects may cause a permanent offset in the reference readings for the sensors and may impact correct operations of the sensors Indicators The DSP 13M is equipped with two LED indicators Power Green and Detect Red Power LED The green power LED has four possible states OFF The voltage applied to the detector is less than the minimum display voltage of approximately 3 3 volts The detector should not be operated below 7 volts DC as unpredictable operation will occur R
8. commonly referred to as Pulse On Entry When pulse mode is selected the channel will output a pulse when the vehicle is first detected and will not output again until the detection zone is no longer occupied Sensitivity The detector has ten user selectable sensitivity levels In most situations the setting of 5 will work effectively The sensor does have hysteresis between the detect and drop thresholds to ensure that the detector output does not chatter during fringe detections Fail Safe vs Fail Secure Here s a little note on fail safe versus fail secure operation In general a fail safe detector will output detect when the sensor circuit is failed This is always useful on a safety sensor to prevent accidental closure of a gate arm ona vehicle On the free exit sensor this will keep the gate open until the situation is fixed This is useful in applications where it is important to allow traffic flow to continue A fail secure detector will never output detect when the sensor circuit is failed This will keep the gate closed This is useful in high security areas or installations where containment is needed Fail Safe When the detector is in the presence mode of operation and a sensor failure is detected the output will stay activated during the failure In gate applications this feature is used to automatically open the gate if a sensor fails It should be noted that a power failure will always result in a fail secure oper
9. condensing Page 4 of 15 DSP13_ MAN _B Mechanical Data DSP 13M Mounting Position Any DSP 13M Housing Material ABS DSP 13M Size 2 375 inches High x 2 340 inches Wide x 860 inches Deep 60 36mm High x 59 44mm Wide x 21 84mm Deep EN Detect O SENSITIVITY Green LED On Normal Green Blink Failure Red LED On Detection Red Blink Reset Required Dip Switch Settings 1 OFF Fail Safe ON Fail Secure 2 OFF Presence ON Pulse 1 DSP 13 User Manual Page 5 of 15 DSP13_MAN_B DSP 13S Mounting Position DSP 13S Housing Material DSP 135 Size DSP 13S Lead in Diameter DSP 13S Lead in Length pai 0 312 650 9 175 DSP 13 User Manual Any Yellow Polyolefin 650 inches High x 3 500 inches Wide x 312 inches Deep 16 51mm High x 88 90mm Wide x 7 92mm Deep 175 75 feet Page 6 of 15 DSP13_MAN_B 4 Features and Functions Presence Detection The output will remain activated as long as a vehicle is sensed in the detection zone This detector always operates in a permanent presence or infinite presence detection mode The sensor technology used is capable of remembering vehicles in the detection zone even if the power is interrupted for long periods of time In fact it can determine if a vehicle arrived in the detection zone while power was removed and provide the correct presence output on power restoration Pulse Detection The pulse mode used is
10. correct voltage is applied and the power LED is still flashing replace the detector Power LED Shows Two Quick Flashes Once Every Two Seconds This flash rate indicates that the detector has had a failure of a sensor or its wiring but is currently working correctly Intermittent failures are usually wiring connections Any splices in the lead in cable should be redone If there are any wire nuts used in the loop circuit remove them and replace with a crimp connection or preferably a soldered connection The fault could also be a fatigued point in the cable This can occur at locations where the cable cross an expansion joint in the road surface Any place where the cable must move even if only a very tiny amount can cause wire fatigue The actual failure point may be very difficult to find Often the sensor must just be replaced if the issue persists but cannot be found Other possible source of fault is a foreign object being embedded in the saw cut and damaging the cable or sensor Another is that the cable has been damaged where it enters or exits a conduit or junction box or that a conduit that the cable is in has been damaged crushed kinked bent cut etc Detect LED Flashes Quickly 5 Hz This flash rate indicates that the sensitivity setting has been changed but has not been sent to the sensor by pressing the reset switch Press the reset switch to activate the new sensitivity setting or return the sensitivity setting to its origina
11. e type of driving surface and if the site is new construction or existing For existing driving surfaces of asphalt or concrete a single 5 16 saw slot can be cut to the desired location of the sensor with an appropriate cutting disk for the road surface The sensor will fit into this saw slot it may be tight where the heat shrink goes over the lead in cable at the sensor This is expected and can be pressed in to the saw slot The saw slot should be deep enough that the sensor and lead in cable will have a minimum of Y of sealant above them in the slot More is better Going too deep with the saw cut is also a concern Deep cuts in a road surface may impact the structural strength of the roadway especially if any reinforcement material is cut Once the saw slot has been cut the slot should be cleaned of all loose material High pressure air should be directed in to the saw slot to remove all debris This will also help remove dust from the saw cutting operation from the sides of the saw slot This will allow better adhesion of the sealant to the saw slot In order to keep the sensor cable at the bottom of the saw slot 1 to 2 pieces of backer rod should be placed in the saw slot every 1 to 2 feet The backer rod should be sized such that it fits snugly in the saw slot Use a blunt object not a screwdriver to press the backer rod pieces down into the saw slot as far as they will go Keeping the sensor cable at the bottom of the saw slot a
12. ere are no internal DIP switches or jumpers to configure When a DIP switch is moved to the left position it is in the ON condition The right position is OFF Some of the settings used paired switches So the user must be sure to set both of the switches in the correct position to get the desired operation Pulse Presence Switch 2 This switch determines if the detector operates using presence detection or pulse detection The switch setting takes effect immediately when changed OFF the presence mode of operation is selected ON the pulse mode of operation is selected Fail Type Switch 1 This switch determines if the output operates in a fail safe or fail secure mode of operation During fail safe operation when the detector is in the presence mode of operation and a sensor failure is detected the output will stay activated during the failure In gate applications this feature is used to automatically open the gate if a sensor fails DSP 13 User Manual Page 12 of 15 DSP13_ MAN _B During fail secure operation when the detector is in the presence mode of operation and a sensor failure is detected the output will stay deactivated during the failure In gate applications this feature is used to keep the gate closed if a sensor fails It should be noted that a power failure will always result in a fail secure operation Fail safe operation is only available when a valid input voltage is applied to the detector
13. he DSP 13M and DSP 13S make up the TRI Axis Detection TRIAD system The TRIAD system is based on a technology that measures very small changes in the earth s magnetic field in all three axes This means that the TRIAD system works properly regardless of the orientation of the sensor With sensor orientation no longer an issue the installer is able to install the sensor in whatever manner best suits the site The TRIAD system can be installed using a single saw cut The sensor is potted in epoxy to provide durability and small enough that it can be placed right in the saw cut It can also be installed up to three feet below the driving surface This allows the TRAID sensor to be placed below pavers in a driveway or under asphalt or concrete in new construction The TRIAD system was specifically developed for access control systems that need reliable vehicle detection for all weather conditions with a minimally invasive installation The system is comprised of two parts a master unit DSP 13M and a sensor DSP 13S Up to two sensors can be connected to a single master The advanced sensor s small size and high sensitivity make it ideally suited to vehicle detection applications The detector uses a 10 pin Molex connector for connections This can be plugged into a Diablo Controls RK 1 RK 50 or RK 51 rack One of the distinguishing features of the TRIAD system is its ability to hold detection indefinitely even through power interruptions Even
14. l value to stop the flashing DSP 13 User Manual Page 14 of 15 DSP13_ MAN _B Detect LED Intermittently Comes On Stays On Without a Vehicle Present This type of symptom is usually caused by one of two issues electrical interference or moving objects in proximity to the sensor Electrical Interference There are several possible sources of electrical interference power lines and electric motors just to name a few Anything that uses electricity is a possible source for electrical interference depending on its proximity to the sensor and the amount of energy being used If you believe the sensor is experiencing electrical interference turn off the device believed to be the source of the interference and see if the problem goes away Sometimes this is not possible and more technical means are needed to help identify the source Call Technical Support in this case Moving Objects in Proximity to the Loop Objects that can move and are ferrous metallic or somehow electrically conductive may cause detection issues A common issue is movement of a slide gate or gate arm in close proximity to a sensor The best solution would be to move the detection area further away from the moving gate We recommend that all sensors should be at least 6 feet from a slide gate Try lowering the sensitivity one level at a time so that the desired vehicles are still detected but not the moving gate NOTE Do not lower the sensitivity too much or vehicles
15. llows the sealant to provide the maximum amount of protection possible from foreign object penetration Never use a continuous piece of backer rod over the sensor and cable as this would prevent the sealant from encapsulating the sensor and cable The sealant used should be appropriate for the roadway surface that was cut Generally epoxy or polyester based sealants are used for concrete surfaces and polyester or urethane based sealants are used for asphalt surfaces However these are not hard guidelines and specific circumstances will determine which type of sealant should be used For existing driving surfaces made of pavers a line of pavers can be removed to the desired sensor location The sensor should then be dug down a couple of inches below the pavers and placed in a bed of sand and covered with at least an inch of sand The lead in cable should also have a small amount of sand cover over it to protect it from the pavers For new construction sites the conduit stub up is the l PAVER INSTALLATION preferred installation method This method is the best PAVERS installation method when a decorative driving surface will be used and disturbing the driving surface in the future is a concern in the event that a sensor fails A 1 Schedule 80 conduit can be stubbed up at the desired detection point in the mo q FILL WITH SAND driving surface This conduit is then sleeved with a 2 Schedule i i 80 conduit that is used to p
16. rotect the sensor It is important 4 1 Se te that these conduits be PVC and not metallic The 1 conduit FILE WITH PLUMBERS PUTTY can transition to metallic pipe after the elbow if desired Us I SCH 80 CONDUIT Once the sensor cable is pulled through the 1 conduit the l 2 SCH 80 CONDUIT sensor should be held 2 down from the top of the 2 conduit j DSP 13 User Manual Page 11 of 15 DSP13_ MAN _B sleeve while the 1 conduit opening is sealed with plumber s ASBUALTOR CONCRETE INSTALLATION putty This is done to keep the sand used in the next step from filling the 1 conduit Now that the 1 conduit is sealed fill the i sleeve with sand 1 from the top if a sealant will be used to oh cap the sleeve If the sensor cable needs to be spliced to another cable to get to the detector the splice should be done in a junction box and the connections should be soldered and weatherproofed FILL WITH SEALANT FILL WITH SAND DSP 13S SENSOR FILL WITH PLUMBERS PUTTY 1 SCH 80 CONDUIT a 2 SCH 80 CONDUIT 6 Configuration Detect SENSITIVITY FUNCTIONS Sensitivity The ten position rotary switch is used to set the sensitivity For most installations the setting of 5 will work well If motorcycle detection is required you may need to use a higher setting DIP Switches There are two DIP switches for adjusting the configuration of the TRIAD system Th
17. will no longer be detected Another possibility is metal objects in close proximity to the loop Utility manhole covers are objects that may move slightly when vehicle tires drive over them especially if the vehicle turns while a tire in on the cover Most manhole covers can be bolted in place Contact the owner of the manhole to see what can be done to mitigate the cover movement Detect LED Will Not Come On With a Vehicle Present The first thing to do is verify that the LED in question is still working This is accomplished by a quick lamp test Reset the detector by pressing the reset switch Both LEDs should flash at least once If the red detect LED does not illuminate then replace the detector If the red LED illuminates then perhaps the sensitivity setting is too low In most cases the sensitivity setting of 5 is the correct setting However to compensate for some unusual site geometries this setting may be inadequate Adjust the sensitivity by one level higher at a time and recheck the detector for proper detection If the sensitivity is set to 9 and the red LED still does not come on swap the sensors between a working detector and the detector with the issue If the problem follows the sensor the sensor is the problem If it stays in the detector replace the detector DSP 13 User Manual Page 15 of 15 DSP13_ MAN _B
18. zone and the detector at the same time Mounting The detector will function when mounted in any orientation When using a rack it is best to mount the rack such that the front panel of the detector will be easily accessible for configuration and troubleshooting Wiring When the detector is plugged in to a rack the rack will provide and identify the wiring connection points Sensor Installation The reliability and overall performance of the detector are greatly dependent on the installation of the sensor itself There are three factors that go into a good sensor installation sensor location type of wire used if additional lead in is needed and installation practices Sensor Location The sensors sense changes in the earth s magnetic field The length of the edge facing the sensor will affect its detection distance As a vehicle approaches a sensor head on it presents an edge approximately 6 six foot long However if the vehicle drives by the side of the sensor it presents an edge of typically 12 to 15 feet Therefore the sides of a vehicle are easier to detect than the vehicle head on This causes the detection pattern to be oblong in the driving lane Usually 25 to 50 wider than it is long If the travel lane if wider than 15 feet it may be advisable to use two sensors with the one master The second sensor can be placed without concern for proximity to the other sensor The sensors will not interfere with each other in any way