1. Site configuration sites configuration Synchronization For each coonfigured site select the needed synchronization type CSTLocale PlantvisorPR O MODEM Site configuration Alarms Notes Synchronization configuration Name Data to synchronize No data Site configuration P Events MM Notes code 030220761 rel 2 0 dated 11 12 06 12 Quick Guide PlantVisorPRO Remoto 4 Scheduler 4 1 Configuration of the I O peripherals All functions that allow the supervisor to communicate with the outside can be configured by means of configuration of the I O peripherals These are Fax set a modem Fax in order to send any alarms or reports SMS set a modem GSM or analogical to send any alarms by means of an SMS message E mail set an electronic post box in order to send any alarms or reports by e mail RAS Remote Access Service set a connection to a local supervisor Window set a noise that the computer where the PlantVisorPRO supervisor is installed will make when the alarm window is visualised To set the configuration of the Input Output peripherals of the supervisor select Configuration of I O peripherals from the Scheduler menu The following page will open an i admin PlantvisorPRO 2006 12 07 13 43 26 Global 1 0 configuration Fax Window e ie Select the modem used to send FAXES and enter the details of possible recipients in the address book
2. PlantVisorPRO Remoto admin PlantvisorPRO 2006 12 07 14 24 44 Global Alarms and events management Rules Time bands Actions To edit an action double click the corresponding row in the list below To add a new action enter the description then click the image Then double click the new row entered in the list highlighted in red Description Name a Double click on the red line in the list of actions and the following page will open admin PlantvisorPRO 2006 12 07 14 27 13 Global Alarms and events management gt action configuration Fax SMS PrintwWindow Action Allarm action Numbers configured for the action ni al E ni Suppose that it is necessary to set the sending of a fax and the visualization of the alarm display for the explanation of all other settings refer to the PlantVisorPRO Full User Manual The Number list table in the Fax section contains the address book that was set when the fax modem was configured see Configuration of I O peripherals chapter Setting the modem to send fax sub chapters Introduce the address boo items of interest by selecting them and clicking onhd Click on to save the settings code 030220761 rel 2 0 dated 11 12 06 24 Quick Guide PlantVisorPRO Remoto 1 E ST oe oe Y admin PlantvisorPRO 2006 12 07 14 27 54 AKIO P Pian Global Alarms and events management gt action configura
3. pP fl a rn tVi 0 r admin PlantvisorPRO 2006 09 29 15 52 43 n T Global Site configuration Sites configuration Synchronization PRI V To edit a configured site double click the corresponding row in the list below To remove a site select the row in the list below and then click the image Site Mame EstLOcale Type PlantVisorPRO a Identifier csTLocale Password ETTET Type of connection MODEM aj Telephone number aa code 030220761 rel 2 0 dated 11 12 06 7 Quick Guide PlantVisorPRO Remoto Introduce a name that identifies the site to be supervised into the Name field Select the type of site to be supervised from the Type field e PlantVisor Enhanced if the local site is a PlantVisor Enhanced installation e PlantVisorPRO if the local site is a PlantVisorPRO installation Introduce site identification of the site to be supervised into the Identification field Introduce the password of the site being configured into the Password field The Type of connection field is used to select the type of connection used by the site for communication e MODEM if the local site is connected to a telephone line by means of a modem LAN if the local site is connected by LAN e g a company network This type of connection is only available if the local site is the PlantVisorPRO type If the type of connection selected is modem the telephone number to which the local si
4. Select the modem used to send FAXES and enter the details of possible recipients in the address book In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Configuration Modem win Modem USB v 92 Switchboard o Number of attempts fio Try again after zo minutes Address book referenes RES gt Number 12345678 3 Click onhid The address book will be updated i a n Y I S 6 r i admin PlantvisorPRO 2006 12 07 13 53 08 Global 1 0 configuration Fax E mail RAS Window lt Select the modem used to send FAXES and enter the details of possible recipients in the address book In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Configuration Modem win Modem USB v 92 aj Switchboard o Number of attempts 10 Try again after 10 minutes Address book cet TTT ra o Po E 3 Industry Fax 12345678 al Click MV The settings will be saved code 030220761 rel 2 0 dated 11 12 06 15 Quick Guide PlantVisorPRO Remoto 4 1 2 Modifying an item in the Fax Address book If an item in the Address book must be modified select the item by double clicking and modify the desired fields admin PlantivisorPRO 2006 12 07 13 55 10 Global 1 0 configuration Fa
5. Industry 47 F 4 k k code 030220761 rel 2 0 dated 11 12 06 28 Quick Guide PlantVisorPRO Remoto The address book will include all the recipients of the signals from the scheduler One or more recipients in the address book can be used or alternatively again in the Configuring the I O peripherals pages a specific recipient can be entered for the signals from the guardian If a Scheduler address book entry is removed this event will not affect the list in guardianPRO which is managed separately From the Address book list select the addresses or the numbers to which the guardianPRO signals will be sent then click gt to add these to the List of signals In the event of an error when entering select the incorrect item in the List of signals and click x To save the settings click ea code 030220761 rel 2 0 dated 11 12 06 29 Quick Guide PlantVisorPRO Remoto 7 Glossary Alarm The alarms are status information sent by the supervision system devices and which are elaborated by these to give indications of anomalous situations or faults Alarm Active These are alarms whose cause of triggering has not yet ceased Alarms report the alarms report is a table which on the basis of a beginning and end data set by the user visualises al alarms that have occurred during the indicated time span Alarm Withdrawn These are records of alarms whose cause of triggering has termi
6. In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Configuration Modem Switchboard Number of attempts o Try again after o minutes Address book itens SY Number E uJ he Important note for Fax SMS and E mail using the button on these pages an action can be created for sending the scheduled alarm via peripheral to all the numbers or addresses set in the address book Example If the fax modem has two numbers in the address book pressing creates the Fax Action in the scheduler meaning the alarm fax will be sent to these 2 numbers via modem code 030220761 rel 2 0 dated 11 12 06 13 Quick Guide PlantVisorPRO Remoto 4 1 1 Setting the modem to send fax In order to set the modem for use as a fax machine select the Fax tab LETS Global admin PlantvisorPRO 2006 12 07 13 43 26 1 0 configuration E mail Ras Window Fax gt V Select the modem used to send FAXES and enter the details of possible recipients in the address book In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Configuration Modem Switchboard Number of attempts o Try again after o minutes Address book geforce TTM Number 3 al There are 4 fields in the Configuration
7. historicised variables Site A site is any type of installation managed by PlantVisorPRO Normally the name of the site is used to indicate a PlantVisorPRO installation that can be reached from remote Supervisor Programme able to manage the hardware connected to the computer Its main task is to check the status of the devices and act according tot he rules set by the user keeping a trace User The user is a registered subject authorised to access the supervisor Variable Every device has variables which are setting parameters and or status conditions of the device itself code 030220761 rel 2 0 dated 11 12 06 30 CARE Technology amp Evolution CAREL S p A Via dell Industria 11 35020 Brugine Padova Italy Tel 39 049 9716611 Fax 39 049 9716600 http www carel com e mail carel carel com Agenzia Agency code 030220761 rel 2 0 dated 11 12 06
8. possible recipients in the address book In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set EEE ta Configuration Es Fax gt Vv l Modem Switchboard se i Type analogico GSM gt Number of attempts o Provider Belgium Proximus TAP Try again after o minutes Call Nazionale Address book referees TT MD al Number There are 7 fields in the Configuration area e Modem this field is used to select one of the modems analogical or GSM installed on the supervisor computer This modem will be used to send SMS e Switchboard optional the number that allows external calls to be made if the modem telephone line passes through a switchboard must be set in this field Type set the type of modem Analogical or GSM in this field It is selected in the modem field Provider this field is used to select the provider that is used to send SMS Call to select if the call is international or not National or International Number of attempts In this field set the number of attempts successive to the first that the supervisor will make to send an SMS if the first attempt failed e Try again later Set the time in minutes between one attempt and the next Once all of the settings have been carried out fill the address book with the numbers to which the SMS will be sen
9. the provider used for the connection Number of attempts In this field set the number of attempts successive to the first that the supervisor will make to send an e mail if the first attempt failed Try again later Set the time in minutes between one attempt and the next Once all of the settings have been carried out fill in the address book with the addresses to which the e mail will be sent code 030220761 rel 2 0 dated 11 12 06 18 Quick Guide PlantVisorPRO Remoto In order to add an item introduce a mnemonic name of the e mail address into the Reference field then introduce the e mail address into the Address field admin PlantvisorPRO 2006 12 07 14 08 11 1 0 configuration Fax E mail Window x a Select the SMTP server the sender and the type of connection used to send E MAIL messages and enter the details of possible recipients in the address book Configuration SMTP 192168030 Connection Lan Dialup Sender Supervisor industry com Provider Number of attempts jo Try again after jo minutes Address book Reference Industry email gt o Address Check industry corn x a Click onia The address book list will be updated admin PlantvisorPRO 2006 12 07 14 09 06 Global 1 0 configuration Fax SMS E mail Window gt V Select the SMTP server the sender and the type of connection used to send E MAIL messages and enter the details of possible
10. PlantVisorPRO Remoto CAREL Quick guide LEGGI E CONSERVA AZZ ISTRUZIONI lt READ AND SAVE THESE INSTRUCTIONS Index 1 Access to the SUD Cl VIS Ol aaa ea 5 1 l A thentication IT the System siga dra Ea da E ELE pe 6 2 Configuration of plant sites eee eereneeereneereneneerecacerecaerecanena 7 3 Modily site settings 9 3 1 Setting the synchronisation modes Of a SItC cece cseececceeeeeceeeeeceeeeeseeaeeeeeeeeeseaeeesseeeeesaaeees 10 d Scheduler zaia 13 4 1 Configuration of the I O peripherals iii 13 4 2 PALM ag ssa ras sans i IAN e 22 5 Registering Lhe prOqUCIL sacsavaaaiasanscalasaniasfacaciaaCacavaasCapavsaaisacuanaGanananafaDaLincCanasaasCa nan As 27 6 Configuring guardianPRO c cscccscsseesesseesesneesenseecenseeceaseseensesoenseseeneesenseesonsessones 27 O gUardlalis siente ail zaia 28 EE EE l Stille Gi DD RS O pa E 28 do SGIOSSANY E A E E E E A AEE E EE ci duauc EE ciais cenato 30 Quick Guide PlantVisorPRO Remoto 1 Access to the supervisor In order to access the PlantVisorPRO Remoto visualise the following page in the browser User admin Password levees Language English SERS To do this select Supervisor login page link from the Windows Start menu in the Programmi PlantVisorPRO page F Impostazioni accesso ai programmi Program Updates to Windows Update Accessori Em Accessori
11. VisorPRO Remoto 6 1 guardian RE To access the general configuration of the guardian function from the Configuration menu select the System pages item and then the guardianPRO tab the following page will be displayed an Global Rj admin PlantvisorPRO 2006 12 19 14 33 09 System pages Information System Support quardianPRO Notifications GUARDIAN configuration page EE Configuration Computer localhost Port 1974 Guardian status Working v In the Configuration section set the computer and the port where guardianPRO is connected e Computer name or IP address where the guardian is installed leave localhost e Port number of the port on the computer where guardianPRO is connected leave 1974 See the Full User Manual and contact the network administrator if guardianPRO is installed on another computer in the network Once the settings have been completed click to save the configuration Then select the Signals tab 6 2 Signals Once selected the Signals tab the following page will be displayed admin PlantvisorPRO 2006 12 19 14 35 31 Global System pages Information System quardianPRO Notifications Configuration page for GUARDIAN s notifications Configured notifications will be used by GUARDIAN when errors arise Configuration Address book Notifications list FAX Fax Industry 47 FAX Fax
12. area Modem this field is used to select one of the modems installed on the supervisor computer This modem e will be used to send fax e Switchboard optional the number that allows external calls to be made if the modem telephone line passes through a switchboard must b set in this field e Number of attempis In this field set the number of attempis successive to the first that the supervisor will make to send a fax if the first attempt failed e Try again later Set the time in minutes between one attempt and the next The supervisor will try and send a Fax if the modem is occupied or there are problems during forwarding it will wait for the set period of time and then try to send the Fax again If it is impossible for the modem fax to forward the document the supervisor will try as many times as those set by the user The re forwarding of the Fax will end with the success of forwarding or expiry of the number of attempis Note if the amount of attempts is set at zero the supervisor will only try to send the Fax once Set the numbers that the fax machine must use in the Address book area code 030220761 rel 2 0 dated 11 12 06 14 Quick Guide PlantVisorPRO Remoto In order to add an item introduce a mnemonic name of the fax number into the Reference field then introduce the fax number into the Address field an admin PlantvisorPRO 2006 12 07 13 51 42 Global IVO configuration Fax gt Vv
13. e configured using a double click code 030220761 rel 2 0 dated 11 12 06 10 Quick Guide PlantVisorPRO Remoto admin PlantvisorPRO 2006 09 Global Site configuration Sites configuration Synchronization For each coonfigured site select the needed synchronization type CSTLocale PlantvisorPR O MODEM Site configuration Alarms Notes Synchronization configuration Name Data to synchronize W No data Site configuration Alarms Events Notes Select the items relative to the data to be synchronised in the Synchronisation Configuration area For example if all of the events notes and alarms of the refrigerated counter are to be controlled by the remote supervisor it is necessary to select the Events and Notes and Alarms boxes admin PlantvisorPRO 2006 09 Site configuration Sites configuration Synchronization For each coonfigured site select the needed synchronization type CSTLocale PlantyisorPRiO MODEM Site configuration Alarms Notes g am y Borers 08 PER A Synchronization configuration Name Data to synchronize No data W Site configuration M Alarms Events Iv Notes Note that if anything else but No Data is selected the Site Configuration item will always be selected To save the settings click code 030220761 rel 2 0 dated 11 12 06 11 Quick Guide PlantVisorPRO Remoto admin PlantvisorPRO 2006 09
14. en Vendor ID IDTACentaur Via Inc CPU Type ID 0 Family ID 6 Model ID 9 Stepping Code amp Brand ID VIA Nehemiah 491 000 KB DO T Yo 33 465 MB 4 681 MB 00 90 05 06 00 81 PlantVvisorPRO version 2 06 CiCarel PlantV isorPRoA CiCarel plantvisoreroV engineWwebapps WebSuperwisork Remoto Advanced Serial number m m Activation code On the www carel com site click the Request PlantVisorPRO activation code link fill in all the fields on the application form Important The MAC address on the PlantVisorPRO system page is required as well as the Serial Number printed on the CD or on the label at the bottom in the case of PlantVisorPRO Embedded Once the data have been confirmed a page will be displayed showing the activation code to be entered in the system page To save the activation code for the supervisor click Then logout and login to PlantVisorPRO again 6 Configuring guardianPRO guardianPRO is an application that ensures maximum system reliability All the processes are monitored and in the event of hardware or supervision software faults guardianPRO independently generates an alarm signal via SMS fax or e mail to warn the user N B guardianPRO must be configured with at least one alarm signal even simply Alarm window to avoid restarting the unit if guardianPRO cannot signal the alarm situation code 030220761 rel 2 0 dated 11 12 06 27 Quick Guide Plant
15. eriod of time that is to be set e g Always Select the action to be set e g Alarm action Introduce the delay in minutes which is desired for the actuation of the rule when faced with an alarm Click M The settings will be saved The following page will be visualised admin PlantvisorPRO 2006 12 07 14 40 05 Global Alarms and events management Rules Time bands Actions Mi E V Rules for managing actions against alarms General Rules allarme attivo Active alarm Sempre Always Toujours Immer allarm action 1 2 e E k Rule Description Enabled w Condition Time bands Actions Delay minutes The Enabled field is used to enable or disable a determined created rule If the tick is left then the rule results enabled for the supervisor code 030220761 rel 2 0 dated 11 12 06 26 Quick Guide PlantVisorPRO Remoto 5 Registering the product is To register the product from the Configuration menu select the System pages item the following page will be displayed admin PlantvisorPRO 2006 12 19 14 29 31 System pages Information System System System language Processor Total physical memory RAM Used physical memory RAM percentage Used CPU percentage Free space Used space MAC address Fersion Product folder Software folder Installation Trpe quardianFRO Notifications Windows P 5 1 Service Pack 2 Us
16. es CAREL 1 Esecuzione automatica H PlankvisorPRO PostgreSQL 6 1 k OpenOffice org 2 0 Trend Micro OfficeScan Client Adobe Reader 7 0 na O O E Assistenza remota E Internet Explorer ea Outlook Express Tutti i programmi amp Windows Media Player Ea Disconnetti o Chiudi sessione code 030220761 rel 2 0 dated 11 12 06 5 Quick Guide PlantVisorPRO Remoto 1 1 Authentication in the system To access PlantVisorPRO introduce User admin Password admin only use lower case characters And click on the Login key to confirm access the following page will appear a n tV S re r admin PlantvisorPRO 2006 09 29 15 47 56 Global Sites list List of sites Devices non presenti Menu Icon code 030220761 rel 2 0 dated 11 12 06 6 Quick Guide PlantVisorPRO Remoto 2 Configuration of plant sites Plant configuration is obtained by setting the sites Each local site can be connected to PlantVisorPRO Remoto by means of a modem and if the local site is the PlantVisorPRO type also by the computer LAN E To configure the plant place the mouse arrow on the icon A menu will appear select Sites configuration i Y tad admin PlantVisorPRO 2006 12 04 17 46 24 Global Sites list CONFIGURATION Site configuration User configuration System pages The following page will be visualised
17. in order to set the audio file with wav extension to be carried out by the computer where the supervisor is installed during visualisation of the alarm window an W admin PlantvisorPRO 2006 12 07 14 15 42 Global IVO configuration Fax window The Wa file played when displaying the alarm window can be selected Warning the file must reside on the computer where the supervisor is installed Configuration Current Sound Sfoglia There are 2 fields in the Configuration area Current identifies the actual sound file configured Sound Allows to use the Browse button to select a sound file present in the computer where the supervisor is installed Click on to save the settings code 030220761 rel 2 0 dated 11 12 06 21 Quick Guide PlantVisorPRO Remoto 4 1 8 Checking functionality of the I O peripherals In order to check functionality of the Input Output peripherals of the supervisor select I O peripherals test from the Scheduler menu The following page will be visualised Global 2006 12 07 14 16 59 j IVO test page Test I O a To execute the test select an action type and its recipient then click the button i Action types Fax sms E mail Print O Alarm window e Select the I O peripheral that is to be checked from the Peripheral list section e Select the receiver a4 e Click on t The I O peripheral will be made t
18. nated Area Logical unit of groups and or devices Daily report The daily report is a table that visualises the values of several historicised variables selected by the user on the basis of indicated data Device This is an electronic device connected to a supervision network and which can be managed by PlantVisorPRO Event Events are information sent by devices I O peripherals or generated by the supervisor itself This information communicates the general functioning status of the supervisor Group Logical group of devices Groups can be used to create group variables Group variable logical superstructure with writing variables that belong to different devices that are necessarily introduced into the same group Historical report The historical alarms report is a table which on the basis of a beginning and end data set by the user visualises the values of historicised variables and selected by the user Instantaneous values report The instantaneous values report is a table that visualises the instantaneous values those detected on printing of the variables of a given device Local supervisor A local supervisor is a device control and management system Network A network is a group of connected devices and supervised by PlantVisorPRO i e devices converters etc Remote supervisor A remote supervisor is a local supervisor centralised control system Report Reports are tables depending on time that contain data of the
19. o work in order to check its effective functionality 4 2 Alarm managment To be informed of all alarms proceed as follows To set a configuration for the management of alarms and events in the supervisor select Alarms and events management from the Scheduler menu The following page will appear code 030220761 rel 2 0 dated 11 12 06 Do Quick Guide PlantVisorPRO Remoto admin PlantvisorPRO 2006 12 07 14 22 42 Global Alarms and events management Rules Time bands Actions Rules for managing actions against alarms Rule Description Enabled m Condition Time bands Actions Delay minutes Select the Actions tab The following page will appear an admin PlantvisorPRO 2006 12 07 14 23 53 Global Alarms and events management Rules Time bands Actions To edit an action double click the corresponding row in the list below To add a new action enter the description then click the image Then double click the new row entered in the list highlighted in red Description Mame To add a new action introduce the mnemonic description into the Name field e g Alarm actions then click on The settings will be saved Successively double click the new line in the list red which has been introduced In this way it is possible to set the type of functionality for this action code 030220761 rel 2 0 dated 11 12 06 23 Quick Guide
20. ok Configuration SMTP 192168030 Connection LAN Dialup Sender Supervisor industry com _ Provider Number of attempts fo Try again after fo minutes Address book FOR _r____c_cc At Email Industry Check industry com al Click on to save the settings code 030220761 rel 2 0 dated 11 12 06 20 Quick Guide PlantVisorPRO Remoto 4 1 6 Setting for remote calls To set the possibility for calls to a computer select the RAS tab an Global admin PlantvisorPRO 2006 12 07 14 14 19 1 0 configuration Fax SMS E mail Window Select the modem to use for outcoming calls towards Local Supervisors Moreover itis possible to select modems to use for incoming calls from Local Supervisors Configuration Switchboard Modem Modems to use for incoming calls LI Win Modem USB 4 92 Li Modem standard a 9600 bps Li PCI Softva Data Fax Modem with SmartCP It is possible to select the modem that is to be used for calls to Local Supervisors in the Configuration area The switchboard field optional must be used to set the number that allows calls to the outside if the modem telephone line passes through a switchboard Moreover it is possible to select the modem with which to receive calls made by the Local Supervisors themselves Click on to save the settings 4 1 7 Setting the audio files to be used during the visualisation of the alarm window Select the Window tab
21. recipients in the address book Configuration SMTP 192168030 Connection LAN Dialup Sender Supervisar industry com Provider Number of attempts fo Try again after fo minutes Address book Address A A TTT a Industry email Checkimindustry com al Click on to save the settings code 030220761 rel 2 0 dated 11 12 06 19 Quick Guide PlantVisorPRO Remoto 4 1 5 Modifying an item in the e mail Address book If an item in the Address book is to be modified select the item to be modified using a double click and modify the desired fields an Global PlantVisorPRo 2006 12 07 14 12 14 admin I O configuration Fax Window lt Select the SMTP server the sender and the type of connection used to send E MAIL messages and enter the details of possible recipients in the address book Configuration SMTP 192 168 030 E Connection LAN Dialup Sender Supervisor industry com Provider Number of attempts fo Try again after fo minutes Hal i Inti distrair Rd Da Address book Reference Email Industry A Rc Check industry com a Industry email Check industry com al Click on lad admin PlantVisorPRO 2006 12 07 14 13 10 Global 1 0 configuration Fax E mail Window 5 V Select the SMTP server the sender and the type of connection used to send E MAIL messages and enter the details of possible recipients in the address bo
22. red site double click the corresponding row in the list below To remove a site select the row in the list below and then click the image Site Name fEsTLocale ae Type FlantvisarPRO Identifier csTLocale Password ecenecceeee Type of connection MODEM Telephone number jai Modify the fields to be corrected and click code 030220761 rel 2 0 dated 11 12 06 9 Quick Guide PlantVisorPRO Remoto PlantVi S oO r O admin PlantvisorPRO 2006 09 29 15 55 52 9 Global Site configuration Sites configuration synchronization To edit a configured site double click the corresponding row in the list below To remove a site select the row in the list below and then click the image PlantvisorPRO Site Mame Type Identifier Password Type of connection Telephone number 3 1 Setting the synchronisation modes of a site In order to set the synchronisation modes of a site select the Synchronisation tab The following page will be visualised admin PlantVisorPRo Global Site configuration sites configuration Synchronization For each coonfigured site select the needed synchronization type CSTLocale PlantvisorPR O MODEM Site configuration Alarms Notes f dalir o Da Synchronization configuration Mame Data to synchronize No data Site configuration P Events TM Notes Select the site whose synchronisation must b
23. t The numbers the supervisor will use to send SMS will be set it in the Address book area This part functions exactly like the fax tab Click on to save the settings code 030220761 rel 2 0 dated 11 12 06 17 Quick Guide PlantVisorPRO Remoto 4 1 4 Setting the e mail function To set the data necessary to send an E Mail select the E Mail tab a n admin PlantvisorPRO 2006 12 07 14 05 36 Global 1 0 configuration Fax E mail Window DIV Select the SMTP server the sender and the type of connection used to send E MAIL messages and enter the details of possible recipients in the address book Configuration She O Connection Lan Dialup Sender Provider Number of attempts fo Try again after fo minutes Address book geforce TTT Address al uJ There are 6 fields in the Configuration area SMTP Name of post server or the IP address supplied by the internet access provider Sender sender s e mail address Attention some post providers require a valid sender address accepted by the post server it is therefore necessary to obtain this information from the supplier of the post service Connection this field is used to set whether the e mail provider is in LAN or is contacted through a modem DialUp The following fields are only enabled if DialUp has been selected in the Connection field Provider this field is used to select
24. te modem is connected must be introduced into the Telephone field If the type of connection selected is LAN then the local site IP address must be introduced into the server IP field To save the settings click on The following page will open PlantVisor Global admin PlantvisorPRO 2006 09 29 15 55 52 a T Site configuration Sites configuration synchronization To edit a configured site double click the corresponding row in the list below To remove a site select the row in the list below and then click the image Type Identifier Password Type of connection ai Telephone number code 030220761 rel 2 0 dated 11 12 06 8 Quick Guide PlantVisorPRO Remoto 3 Modify site settings PlantVisor Global admin PlantvisorPRO 2006 09 29 15 55 52 Site configuration Sites configuration synchronization To edit a configured site double click the corresponding row in the list below To remove a site select the row in the list below and then click the image PlantvisorPRO Type Identifier Password Type of connection aj Telephone number To modify the settings of a site double click on the line to which the site belongs the fields will fill with the data regarding the selected site PlantVisor Global admin PlantvisorPRO 2006 09 20 15 55 52 Site configuration Sites configuration synchronization To edit a configu
25. tion Fax SMS E mail Print window Action Allarm action To return to the action setting page click on the Alarm and events management link that is positioned above the Tab Alarms and events management gt action configuration Fax SMS 2006 12 07 14 37 28 E a n Y i S 6 r admin PlantvisorPRO Global Alarms and events management Rules Time bands Actions To edit an action double click the corresponding row in the list below Allarmi action aff To add a new action enter the description then click the image Then double click the new row entered in the list highlighted in red Description name ap The line in the list of actions which was previously red is no longer this colour and has ticks corresponding to the types of action set see in this example the Fax columns Now select the Rules tab The following page will appear code 030220761 rel 2 0 dated 11 12 06 25 Quick Guide PlantVisorPRO Remoto admin PlantvisorPRO 2006 12 07 14 22 42 Global Alarms and events management Actions Rules Time bands Rules for managing actions against alarms xl Rule Description Enabled m Condition Time bands Actions Delay minutes Introduce a mnemonic description of the rule to be created in the Rule section in the Description field e g General rule Then select the condition in alarm Select the p
26. x E mail RAS Window R e Select the modem used to send FAXES and enter the details of possible recipients in the address book Configuration In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Modem win Modem USB v 92 Switchboard fo Number of attempts io Try again after 10 minutes Address book O mms o alli Number 12345678 a Industry Fax 12345678 ha admin PlantvisorPRO 2006 12 07 Global 1 0 configuration Fax x lt Select the modem used to send FAXES and enter the details of possible recipients in the address book Configuration In addition both the number of attempts to be performed after the failure of the first attempt and the delay between one attempt and the next can be set Modem win Modem USB 402 Switchboard o Number of attempts fio Try again atter fio minutes Address book reference a all MO ESA a Fax Industry 12345676 al Ed Click on to save the modifications code 030220761 rel 2 0 dated 11 12 06 16 Quick Guide PlantVisorPRO Remoto 4 1 3 Setting the modem to send SMS In order to set the modem to send SMS select the SMS tab a n y S O r a admin PlantvisorPRO 2006 12 07 14 00 41 Global I O configuration E mail RAS Window Select the modem used to send SMS messages and enter the details of