1. Press Instant to remove entry delay from the Exit Entry door Arming Your System Arming Your System When Leaving 1 Before arming your system make sure the green Status light is ON This indicates that all of your protective zones are secure If any zones are open the corresponding Zone number will be lit Secure these zones before proceeding If any zones cannot be secured see Bypassing zones below 2 Enter your user code and press The green Status light will go out the red Armed light will light e f you make a mistake entering your code press RESET re enter the code and press e f FIREMbis lit the Fire zone has not been properly reset Press Reset enter your user code and press a See Silencing a Fire Alarm page 8 3 Leave the premises through the Exit Entry door If the keypad gives a steady tone you have taken too long Enter your code again to disarm system and then re enter code and leave Easy Arm The optional Easy Arm feature allows the system to be armed by simply pressing This will allow the easy arming of the system by someone who is not a regular system user Bypassing Zones If an open zone cannot be immediately fixed it can be left unprotected or bypassed while the rest of the system is Armed To bypass a zone 1 Press Ers followed by the number of the zone to be bypassed The bypassed zone s number will flash slowly 2 Enter your user code and press The green Status light will go
2. Keypad Beeps or Zone light System Trouble Action Flashes O Condition 2 Beeps Fire Trouble A problem has been detected in the Fire Circuit Call installing company for service 2 Beeps Wireless Receiver A problem has been detected with the wireless receiver Trouble Call installing company for service 2 Beeps Wireless Receiver Jam A problem has been detected with a wireless receiver Call installing company for service 3 Beeps Wireless Transmitter The battery in a wireless transmitter is low and should be replaced This transmitter is Low Battery on the zone corresponding to the number of the lit zone light The replacement battery for the GEM Trans2 door window transmitter GEM PIR motion detector and GEM GB glass break detector is the Duracell DL123A 3 volt lithium 2 required for the GEM PIR Wireless Transmitter A problem has been detected with a wireless transmitter Supervisory Failure Call installing company for service Wireless Smoke The battery in a wireless smoke detector is low and should be replaced This wireless Detector Low Battery smoke detector should be marked with a number corresponding to the number of the lit zone light The replacement battery is the Duracell MN1604 9 Volt Alkaline 2 required Warning Replace batteries only with the same type as specified above Use of another 2 3 4 1 and GEM GB The GEM DT Dual Technology Sensor requires 4 C cell alkaline batter ies Warning Replace batteries o
3. Emergency the central station of a fire emergency if so programmed Enabled Yes E No E Auxiliary Alarm Simultaneously press L84 L _ to alert the central station of an auxiliary emergency if so programmed The nature of this emergency alarm is to be determined by the installer se C Police Emergency Police Emergency Simultaneously press L_9 L _ to sound a police emergency alarm Enabled and to alert the central station of a Police emergency if so programmed Yes C No C Ambush Alarm Ambush Alarm Enabled In the event that you are forced by an intruder to disarm your system the ambush alarm can be activated Disarming the system with the Ambush Code will cause the system to disarm and Yes LI No E simultaneously send a silent ambush alarm signal to Central Station If your system has the Ambush feature enabled the code assigned as the User 8 code will function as your Ambush Code Disarming Your System Silencing an Alarm Disarming Your System when Returning 1 Enter your premises through the Entry Exit door The keypad will sound a steady tone to remind you to disarm the system before your Entry Delay time expires 2 Enter your User Code and press a The red Armed light will go out indicating that the system has been disarmed Note If you make a mistake entering your code press RESET and re enter the code followed by Py Alarm Indication If the Red Armed light is flashing rapidly an alarm
4. While Home Emergency Keys Disarming the System Silencing an Alarm Resetting a Fire Alarm Fire Protection Special Functions System Troubles Programming User Codes Glossary Important Test Your System Weekly 1 Bell Battery Test Test your bell or siren by pressing Fton followed by L1 This will cause the bell or siren to sound for 2 seconds andalso initiate a test of the battery 2 Zone Test Walk throughout the premises opening each protected door or window and activating each motion sensor Check the keypad to see that each respective zone number displays in the window System Information Central Station Phone Number Central Station Account Number For Service Call Entry Delay Exit Delay Alarm Time out 3 Central Station Communication Test This test should only be performed on weekends or at a time designated by your alarm company Notify Central Station of the impending test Secure all zones to light Status Light on your keypad 1 2 3 Enter your User Code followed by to Arm the system 4 Violate your alarm by opening a window door etc 5 The siren or bell should sound and the system will send the alarm signals to the Central Station 6 Enter your User Code followed by lto silence the alarm Call Central Station to insure that the alarm signals were received properly 4 Keypad Controls and Indicators AC Light will light to indicate that AC Power i
5. occurred while you were away Proceed with caution For your own protection leave immediately and call authorities from a neighbors phone Silencing an Alarm In the event that the system goes into alarm due to a violated burglary zone the siren and the keypad sounder will activate and the number of the zone inalarm will flash in the display To silence the system enter your User code followed by The keypad sounder and siren will silence but the zone in alarm will continue to flash Press RESET to reset this alarm memory Silencing a Fire Alarm In the event that the Fire alarm activates due to an violated smoke or fire detector the bell or siren will sound a distinct pulsating tone FIRE bon the keypad will be flashing and the keypad sounder will emit a pulsing tone If a Fire Alarm does occur 1 Ifa fire is in progress evacuate the premises immediately Call the Fire Department from an outside phone 2 If there is no evidence of a fire enter your User Code followed by The bell or siren will silence and FIREM will stop flashing but will still be lit 3 Determine which device went into alarm If you are protected by smoke detectors the light on the active detector will be lit Once it is determined which smoke detector is in alarm press to reset the fire zone 4 Ifthe Fire zone has reset properly FIRE should go out in approx 30 seconds If it does not go out press RESET again in a few minutes If it still does not go out call fo
6. red Armed light will flash rapidly while in the Instant Mode Easy Exit optional Your System may have been programmed to allow Easy Exit which allows a user to exit the premises with the system armed By pressing Fuxctonj followed by __0_J the protection is removed from the Exit Entry zone for 3 minutes This will allow for example an early morning commuter to exit the house in the morning without having to disarm and rearm the system waking the family Arming with a System Trouble Present TROUBLE A is lit If the GEM P800 has a system trouble present TROUBLE will be lit and the keypad sounder pulsing If you cannot immediately clear the trouble the system can still be armed Simply press Fron followed by _4_Jto view the trouble Press Meron to view any other troubles and exit the TROUBLE mode when done Enter your User Code and press to arm the system For more information refer to page 12 Note System troubles should be repaired as soon as possible Emergency Conditions FI Le Fire Emergency Emergency Buttons L7F Lsa C eP Lx J The three sets of emergency buttons if programmed are always active whether the system is armed or disarmed Discuss these Buttons with your installer The emergency signal will only be activated when the two respective buttons are pressed at the same time Fire Alarm Simultaneously press _7F J __x_Jto sound a fire alarm and to alert Auxiliary
7. S FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT In case of defect contact the security professional who installed and maintains your security system In order to exercise the warranty the product must be returned by the security professional shipping costs prepaid and insured to NAPCO After repair or replacement NAPCO assumes the cost of returning products under warranty NAPCO shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or removed NAPCO will not be responsible for any dismantling reassembly or reinstallation charges This warranty contains the entire warranty It is the sole warranty and any prior agreements or representa tions whether oral or written are either merged herein or are expressly cancelled NAPCO neither assumes THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the speci
8. Using Your GEM P800 Security System lt BYPASS 4 5 5 RESET 7F 8A 9P Lo J Lx J COMPUTERIZED SECURITY SYSTEM Introduction Congratulations on your purchase of an advanced GEMINI P800 Security System Meticulously developed by a leading manufacturer of state of the art security products this system will provide you with unprecedented peace of mind amp incorpo rates some of the most sophisticated features available today Above all it has been designed an extra step to provide all those operating it with very easy intuitive use Please carefully review the information contained in this manual so that you and all potential users of the system familiarize yourselves with its operation and can therefore take full advantage of GEMINI s many convenience features and amenities Your system consists of a control panel a computer housed within a white metal panel enclosure one or more GEMINI Decorator Keypads for controlling the system and various security detection devices These detection devices are divided among separate areas known as zones set up throughout your premises Each zone number corresponds to a Zone light on your Keypad s display area When a zone s number is ON or lit it indicates that one or more detection device s assigned to that area are active or open For example if Zone 1 is the front door and it is open the 1 on the keypad display will be lit If zon
9. aving to help prevent the fire from spreading 4 Go to your specific outdoor meeting place so you can see that everyone is safe 5 Call the Fire Department from a neighbor s telephone Fire Protection Floorplan Draw a plan of your premises below Special Functions By pressing A can be enabled Easy Arm when system is disarmed The Easy Arm feature allows the system to be armed by pressing Feron followed by _o_J This will allow the easy arming of the system by someone who is not a regular system user Easy Exit when system is armed This function if programmed allows an occupant to leave the premises without disarming the system Pressing followed by while the system is armed will start a 3 minute period during which you can leave through the Exit Entry door Bell Battery Test Pressing followed by will cause the bell or siren to sound for 2 seconds This will also initiate a test of your battery to make sure it is adequately charged The P800 also performs an automatic battery test very 24 hours Access Output If programmed pressing Fuxcton followed by will activate the Access Output which may be configured to open a door strike turn on lighting or activate some other special feature your installer has provided followed by the the appropriate key do not press simultaneously these special functions and features Display System Trouble Pressing Fron followed by when TROUBLE A is lit will cause t
10. e 2 is a motion detector and there is movement in that area 2 will light Depending upon the actual layout your security professional has chosen to properly protect your premises each zone may function a little differently The zone protecting your front door may be programmed as an Exit Entry zone to allow you time to enter the premises and disarm the system without inadvertently sounding the alarm Alternatively a zone protecting a window could be designated as an instant zone so that if it is entered or opened while the system is on armed there will be an immediate alarm Your easy GEMINI Keypad puts super simple system control at your fingertips Most keypad commands involve entering your four digit User Code This includes Arming or activating and Disarming or deactivating the system Simply put ARMED means the system is ON DISARMED means the system is OFF If the system is OFF and you want to turn it ON just enter your Code To turn the system back OFF enter your code again It s easy just always remember in the event of an alarm entering your User Code will silence all Sirens Your keypad is your command and status center it keeps you informed visibly using its zone and status lights and audibly using its built in keypad sounder For more information please see Keypad Controls and Indicators on page 4 Introduction Table of Contents Keypad Controls and Indicators Arming your System When Leaving Protecting Yourself
11. e more user codes to be programmed return to step 1 above otherwise go to Exiting the User Program Mode below Erasing a User Code 1 Press the User number to be erased The keypad will beep 2 times and the corresponding Zone light will flash to indicate the user number you are about to erase 2 Press nst T The zone light will go out to indicate that the user code has been erased 3 If there are more user codes to be erased return to step 1 above otherwise go to Exiting the User Program Mode below Exiting the User Program Mode When you are done programming or erasing User codes press RESET to Exit the User Program Mode Ambush Code In the event that you are forced by an intruder to disarm your system this special code can be used to disarm the system and simultaneously send a silent alarm to Central Station If your system has the Ambush feature enabled the code assigned as the User 8 code will function as your Ambush Code Arming Disarming Turning the system on or off by entering your user code at the keypad followed by Auto Interior Bypass A feature which allows the system to recognize when you have not left the premises and automati cally bypass any interior zones deacti vating devices such as motion sensors allowing free movement throughout the premises Battery A backup source of power to provide protection for a limited time in the event of a power failure Bypass the manual or automat
12. f the illuminated zone Refer to the following table to determine the cause of the trouble If there is more than one trouble to view pressing N80 will scroll to the next trouble and then exit the TROUBLE 44 mode if there are no more troubles to view Keypad Beeps or Zone light System Trouble Action Flashes ON Condition 1 Beep 1 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for service 1 Beep 2 Low Battery If there has been a recent power failure the battery may be partially depleted and must be recharged by the control panel If the trouble does not go away in 24 hours call installing company for service Telephone Line Cut The telephone line has failed If telephone service has been temporarily interrupted 1 Beep the trouble will clear it is when restored Otherwise call installing company for service Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service 1 Beep 3 Communication The system was not able to report to central station If this is due to a temporary inter Failure ruption in the telephone service the trouble can be cleared when the service is re stored by pressing Futon followed by __4_J again to view the trouble and and then pressing Neron to exit Otherwise call installing company for service System Troubles
13. fications in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to radio or television reception which can be determined by turning the NAPCO Security Systems 333 Bayview Avenue Amityville NY 11701 nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise or grow out of Seller s rendering of technical advice or service in connection with Buyer s order of the goods furnished hereunder NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY Warning Despite frequent testing and due to but not limited to any or all of the following criminal ampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or c
14. he system to display any current system troubles Pressing Neron will exit the Display System Trouble Mode Chime Mode On Off Pressing Fuxctonj followed by will activate deactivate the door chime Activating this feature will cause any door to beep the keypad sounder when it is opened Program Mode Pressing Fuxcton followed by will enable the Program Mode which will allow you to program and erase user codes see Programming user codes page 14 Keypad Sounder On Off Pressing Fuxctovj followed by will deactivate activate the keypad sounder depending on its present state By deactivating the sounder on a keypad installed in a bedroom for example you will only turn off that kKeypad s sounder All other keypads on the system will still sound normally LA System Troubles The GEM P800 is constantly monitoring its own components as well as all critical services such as AC power and the telephone line to insure that it is always ready to provide the protection for which it was designed When a system trouble does occur it will caution you by lighting the TROUBLE A light and beeping the keypad buzzer If you cannot immediately clear the system trouble the system can still be used Simply press Fcon followed by _4_Jto view the trouble as described below and then arm the system To determine the nature of the trouble press Fuctonj followed by _4_J count the number of keypad beeps and observe the number o
15. ic re moval of one or more protection zones from the system Press Bass and then the zone number to bypass a zone Central Station Monitors alarm emergency and trouble reports from the alarm system and notifies proper authori ties Chime a keypad beep which indicates that a door has been opened while the system is disarmed Easy Exit Allows an occupant to leave the premises without disarming the sys tem Pressing and then while the system is armed will permit exit by removing the protection on the Exit Entry door for 3 minutes Exit Entry Delay The amount of time you are allowed to enter and leave the premises when the system is armed Exit Entry Zone A zone which will allow you to enter and leave the premises when the system is armed Instant Protection Arming without En try Delay while remaining on the premises Press nst while armed Keypad Sounder A local warning de vice at the keypad to alert that Entry delay has started System Trouble A problem has been detected in the system which may pre vent it from working properly TROUBLE A will be lit to indicate a sys tem trouble User Code A four digit code which is used to arm and disarm the system from the keypad User 1 Code A four digit code which can be used to program re program and erase user codes as well as arm and disarm the system from the keypad Zone An area which is protected by a security device Your fr
16. ircumvented or hat the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all cases provide adequate warning or protection A properly installed and maintained alarm may only reduce risk of burglary robbery fire or otherwise but it is not insurance or a guarantee that these events will not occur CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING Therefore the installer should in turn advise the consumer to ake any and all precautions for his or her safety including but not limited to fleeing the premises and calling police or fire department in order to mitigate the possibilities of harm and or damage NAPCO is not an insurer of either the property or safety of the user s family or employees and limits its iability for any loss or damage including incidental or consequential damages to NAPCO s original selling price of the product regardless of the cause of such loss or damage Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or imitation of incidental or consequential damages or differentiate in their treatment of limitations of liability or ordinary or gross negligence so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may also ha
17. nly with the same type as specified above Use of 5 Beeps 1 battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire 6 Beeps 1 4 Wireless Smoke A problem has been detected with a wireless smoke detector Detector Supervisory Call installing company for service Failure Zone Trouble Call installing company for service 7 8 8 4 6 Programming User Codes Your Installer has assigned a User 1 Code which can be used to not only Arm and Disarm the system but also to enter the User Program Mode where you can program other user codes The following explains how you will use this code to program or erase additional user codes Entering the User Program Mode Press Fco followed by and enter the User 1 code folowed by a The Armed Status and lights will flash and the keypad will beep 4 times You are now in the User Program mode Zones 1 through 8 will light to indicate any User Codes presently programmed Programming Reprogramming User Codes 1 Press the User number to be programmed For example press _2_Jto program the User 2 code The keypad will beep 2 times and the corresponding Zone will flash to indicate the user number you are about to program 2 Press in the 4 digits of the new User 2 code the keypad will beep 4 times 3 If there ar
18. ont door may be designated as Zone 1 while the living room motion detector may be Zone 2 Refer to the Zone Label on your keypad for the Zone Identification of your sys tem NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS INC NAPCO warrants its products to be free from manufacturing defects in materials and workmanship for thirty six months following the date of manufacture NAPCO will within said period at its option repair or replace any product failing to operate correctly without charge to the original purchaser or user This warranty shall not apply to any equipment or any part thereof which has been repaired by others improperly installed improperly used abused altered damaged subjected to acts of God or on which any serial numbers have been altered defaced or removed Seller will not be responsible for any dismantling or reinstallation charges THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ADDITIONALLY THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO Any action for breach of warranty including but not limited to any implied warranty of merchantability must be brought within the six months following the end of the warranty period IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGE
19. out and the red Armed light will light 3 Leave the premises through the Exit Entry door When the system is subsequently disarmed all bypassed zones will be reset ready to be armed again If it is necessary to bypass any inoperative zone s it is important to have the zone s repaired as soon as possible A bypassed zone does not provide any protection compromising system security Arming Your System Protecting Yourself While at Home 1 Before arming your system make sure the green Status light is ON This indicates that all of your protective zones are secure If any zones are open the corresponding zone number will be lit Secure those zones before proceeding 2 Enter your User Code and press The green Status light will go out and the red Armed light will light 3 Before your exit delay expires press BvPsss to bypass any interior zones deactivating devices such as motion sensors and allowing free movement throughout the premises The Zone light of any bypassed zones will flash slowly e Your system may have been programmed for Automatic Interior Bypass in which case it will recognize that you have not left the premises and will automatically bypass any interior zones Instant Mode Pressing xstx7 will cancel the Entry delay activating the Instant mode This is typically done in the evening when all family members are home for the night Instant Mode can be activated at any time after the system has been armed The
20. r service Fire Protection Preparing a Fire Escape Plan Even with the most advanced fire alarm system adequate protection requires an escape plan To prepare your plan draw floor plans of your building Space is provided on the next page Show two exits a front or back door and a window from each room Make sure each window works You may need a special fire escape ladder if the window is high up Write down your outside meeting place Family Rehearsal Rehearse each of the following activities Would You Like More Safety Information 1 Everyone in his room with the doors closed 2 One person sounds the alarm For more information on home fire detection 3 Each person tests his door burn safety and home fire safety write to 4 Pretend that the door is hot and use the alternate escape exit 5 Everyone meets outdoors at the assigned spot National Fire Protection Association Public Affairs Dept 05A Important Read Carefully Batterymarch Plaza Discuss each of these escape procedures with all those who Quincy MA 02269 use the building 1 In aresidence sleep with the bedroom door closed 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat rushes in Crawl through the smoke holding your breath Close the doors again on le
21. s present Fire Alarm Light will flash and the Keypad sounder will beep when system is in a Fire Alarm Condition See Silencing a fire Alarm Page 8 Trouble Light 44 will light and the Keypad sounder will pulse to indicate that a system trou ble is present See System troubles Page 12 Status Light will light when all zones are secure and system is ready to be Armed Armed Light will light when system is Armed and will flash when system is in Alarm Press Fro followed by the corresponding Function number to enable special functions and options See Special Functions Page 11 To Bypass a zone press and the zone number to be bypassed and then Arm system Press to reset Fire Zone clear miss entered codes reset Alarm Memory etc Zone Lights 1 through 8 will light to indicate that the corresponding Zone is open and will flash to indicate a zone in alarm 12345678 4 FUNCTION 1 J 2 j 3 J ON l INTERIOR BYPASS 4j 5 6 RESET 7F j BA j QP 0 j j Numerical Keys 1 9 0 Used to en Emergency Keys Press simultaneously to signal an emergency condition Press C7 C for Fire Emergency Lea 7x Jfor Auxiliary Emergency or LCer LC for Police Emergency Programmable Press to bypass all interior pro tective de vices such as motion sensors etc Press OFF after entering User Code when Arming or Disarming System
22. ve other rights which vary from state to state equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient the receiving antenna relocate the computer with respect to the receiver move the computer away from the receiver plug the computer into a different outlet so that computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock No 004 000 00345 4 O01219C 07 97