Home
YSS-01CK Multi Function Controller
Contents
1. 4 gt Enter OSD manual enter A Up right V Down left 4 Return ESC X Under the control of keyboard Protocol cannot be changed Camera OSD Key Ent 11 8 10 Alarm setup Alarm ON set up Cam 001 Enable Al No Press F1 once 1 10 ENT nable Alarm No __ Alarm OFF set up Press 1 1 10 ENT X Alarm 1 10 correspond to preset position 1 10 X when alarm is triggered there will be warning siren Other than the numerical keys and lens control keys press any key can stop the warning siren Output on off set up DO Camera out put ON set up Press gt 1 8 ENT Camera out put OFF set up Press F2 twice gt 1 8 ENT Cam 001 Inquiry of alarm record Inquiry of previous record F3 Inquiry of previous record F4 X May record the latest 80 alarm information X Display description Cam 001 12 B 001 AL 12 No Any Alarm List No record of alarm been triggered 12 A 001 AL 2 Means the alarm collector 1 point 2 triggered 13 A 001 AL Reset Means alarm collector 1 all reset 14 001 AL 1 2 Means the camera 5 alarm1 and 2 triggered 15 B 001 AL Reset Means camera 5 alarm reset 12 B 001 AL 12 A Alarm TECUM Alarm machine I
2. limit to the left set up move the camera to pan Cam 001 limit to the left press MISC1 ENTI Save limit Start Pan limit to the right set up move the camera to pan limit to the right press MISC2 ENT 10 6 Execute Auto pan group auto cruise auto pan speed set up Dwell time set up Cam 001 Execute auto pan Set Auto Pan AUTO PAN press down 1 time gt ENTI Execute group auto cruise AUTO PAN press down 2 times gt 1 5 gt ENT Cruise speed set up AUTO press down 3 times 1 6 gt ENT Dwell time set up AUTO PAN press down 4 times gt 00 99 ENT X Group auto cruise 1 5 1 auto cruise 1 preset 1 32 Group auto cruise 2 preset 33 64 3IGroup auto cruise 3 preset 65 96 Group auto cruise 4 preset 97 128 Group auto cruise 5 preset 1 128 X Set up cruise speed 1 6 means the approximated movement speed for each second 110 sec 420 sec 30 sec 4 40 sec 450 sec B 60 sec X Set up dwell time 0 99 Second Input 15 means the dwell time is approximately 15 seconds 7 Camera OSD manual operation Cam 001 Camera set up the set up keys on the front panel 19 22 amp
3. D Equipment type A alarm collector gt gt Alarm status sequence 12 11 Keyboard system set up System Setup gt Clear Alarm List SHIFT CAM enter set up manual Use the OSD key A to select the required gt Sure 0 Yes 1 No set up items press down and enter set up mode gt Sure 0 Yes 1 No Enter 0 confirm change or 1 no change and return to previous layer Press down return to previous ESC Set up item gt Clear Alarm List Clear alarm record gt Set Keypad Master Set up keyboard as the main control keyboard needs to be set up when there are two or more keyboards gt Set Keypad Slave Set up keyboard as auxiliary control keyboard needs to be set up when there are two or more keyboards 13 Maintenance amp cleaning Prevent water or other materials fall into the keyboard and cause control abnormal or malfunction Daily cleaning Use soft cloth to wipe clean Removal of stubborn stains The surface of the keyboard is difficult to clean with dry cloth It can be wiped clean with soft cloth with dilute neutral detergents and then wipe clean with soft dry clothe X Detergent on the soft cloth shall not penetrate into the gaps between the keys Do not use benzene diluents or gasoline and other corrosive solvents Solvents may damage t
4. Multi function Control keyboard USERS MANUAL VYSS 0O1CK V3 0 3J 1 om d Thanks for your purchase of our product In order to make good use of this product please read this user s manual carefully In order to use this product correctly and safely be familiar with all operation steps Please keep this user s manual for future reference The information contained in this document is subject to changes without notice SAFETY WARNING In case of failure be sure to turn off the power or remove the power supply before contacting service personnel To avoid electric shocks do not disassemble this product on your own Be sure to ask a skilled technician for the job The power of this product is DC12V 1 2A Do not use other types of power supply or the product may be destroyed or fire can be triggered Keep unconnected wires plugs duly insulated or they might cause short circuit and damage this product Do NOT connect power to the unit until all installation steps are completed Table of Contents Safety warning 3 Introduction 5 Use instructions foetu MEE 5 Friont panel 6 Rear connects line 00000000 8 System integration diagram 1 1 9 Instruction of operation 10 Remarks Maintenance amp cleaning 14 Troubleshooting s n 14 Optional accessories 15 Introduction This product utilizes the mos
5. RS 485 1 X X 2 GND X 3 TxD D 4 RxD 5 X RS233 5485 System integration diagram YSS 01CK EEE YSS IR485 L YSS 2510 l yss 1523 DAE Controller Protocol Converter E mm 9 Tr mier Operation instruction 1 Selection of Camera ID Carta Press CAM key once and enter the camera ID Choose Cam ID _ selection mode input camera ID 001 255 press ENT key to enter Ex CAM 002 ENT 2 Direction control Cam 001 Joystick may control 8 directions Rotation speed can Right Up Choose Cam ID 001 be variable by controlling a joystick OK 3 Lens control Cam 001 Press down FOCUS NEAR FAR or ZOOM IN OUT Zoom Out Choose Cam ID 001 for manual adjustment 4 Preset position Call Save and Clear Cam 001 Call preset position Press PRESET once gt Input camera ID ENTI Save preset point Press PRESET twice Input camera ID ENT Clear preset point Press PRESET three times Input camera ID ENT Call Preset ___ You can set 128 preset position every 32 preset for one group group 1 1 32 Group 2 33 64 Group 3 65 96 Group 4 97 128 5 Pan Limit set up Pan
6. he keyboard Troubleshooting Troubled control a Is the control wire in poor contact Is it properly grounded Is the wire interference by other signal b Make sure you use PVC instrument cable pair type as the extended control wire For RS 485 control c Is the control distance too long Double check the spec of wire 2 Unsuccessful control a Please checks the control wire has properly connected or not b Has the camera ID Properly set Have you selected the correct camera before operating c Is the protocol match to each other camera and keypad For RS 485 control 3 Why the control fails to reach the preset position a Double check is the preset positions in normal operation b Double check the preset positions in a specific group has 2 or more preset positions c Have you set all the preset position of one group in the same position X For technical support please contact the dealer Optional accessories YSS 2348 232 Signal converter For RS 485 control system To convert RS 232 signals into RS 485 signals To convert PC DVR control signals Compact amp lightweight for easy installation Apt for use in indoor environments YSS 4823 485 Signal converter For RS 485 control system To convert RS 485 signals into RS 232 signals Apt for all RS 232 communication systems The system features integrated or extended control distance Compact amp lightweight for easy in
7. stallation Apt for use in indoor and outdoor environments YSS 485A 485 signal amplifier For RS 485 control system Signal amplification for extended control distance Built in surge protection and scramble signal resistance Compact amp lightweight for easy installation Apt for use in indoor environments YSS IR485 Control for camera For RS 485 control system Expandable into a simple one to multiple camera Compact amp lightweight for easy installation IR remote control of easy operation Avariety of humane wireless ratio control features Apt for use in indoor environments 15
8. t advanced communication protocol can integrate the full series of CCTV products produced by SEEKU The powerful control functions can effectively improve system efficiency Large LCD screen make messages easy to read Attached with multi directional variable speed joystick makes control operation easier Accessories 1 Multi function control keyboard 2 RS 485 control connection wiring 3 Power supply 4 User manual Front panel X Keys without a description are not operational in this model Camera selection key Power LED No function LCD Preset point Call Save and Erase Set up auto pan to the left Set up auto pan to the right Auto Pan LED Execute Auto Pan Execute group auto cruise Set dwell time and cruise speed for group auto cruise 10 Call alarm record up 11 Call alarm record down 4 OMAN DOA 0 12 13 14 15 16 17 18 19 20 OSD manual enter key 22 23 24 25 26 21 Output switch ON OFF Alarm ON OFF Number key Enter key No function Keyboard system set up ESC key OSD manual esc key OSD manual Tilt left OSD manual tilt right down gt v Star light night vision adjustment Focus zoom Joystick Rear connects line 27 Power supply DC12V 28 RS 232 communication connection socket 6P6C not supported by this model 29 RS 485 communication connection socket 6P6C Pin RS 232