Air-O-Swiss 7145 Ultrasonic Humidifier User Manual

image

Contents

1. www sylvane com 1 800 934 9194 Foreword Unpacking 10 Congratulations on choosing the Ultrasonic Humidifier e Carefully remove the humidifier from the box Place AOS 7145 7147 from AIR 0 SWISS your hands underneath the product to pull it out of the box 10 Did you know that dry room air e Warning Do not take the unit out of the box by pulling e Causes the membranes in your respiratory system to up on the tank handle base may fall and will be da dry out and also causes chapped lips and stinging maged 11 eyes Remove the plastic bag from the humidifier e Encourages infections and illnesses of respiratory e Observe the information given on the rating plate about system the voltage e Causes weariness tiredness and poor concentration e Use the original packaging for storing the appliance if e Stresses household pets and house plants you do not use the humidifier all year round e Encourages the formation of dust and the electrostatic charging of textiles made of synthetic fibers carpets and plastic flooring 11 e Damages furnishings made of wood and parquet e Detunes musical instruments General information A comfortable atmosphere indoors is reached with a rela tive humidity level between 40 and 60 Your humidifier automatically controls the humidity level according to the desired setting If the air is too dry the humidif
2. 18 and switch on the appliance using the on off dial 19 The empty indi cator light may stay illuminated for some seconds until the base is filled with water Do not use additives Water additives ethereal essential oils fragrances eucalyptus water conditioners etc must not be used Even a small amount can cause cracks in the material The material isn t made for the use of such additives One drop is enough to damage the tank and as a consequence the unit Any use of such additives will void the manufacturer s warranty www sylvane com 1 800 934 9194 Operation AOS 7145 A On Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates the mist output from low to high B Hygrostat setting the humidity level The desired humidity level can be set by turning the rotary switch clockwise A relative humidity between 40 and 60 is recommended You can achieve this level by rotating the switch until it is roughly in the vertical position The accu racy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting The appliance does not switch off if the switch is turned all the way to the right This activates the continuous operation function www sylvane com 1 800 934 9194 C Empty indicator red The wat
3. H shows which of the three levels low medium high you have selected E Operation with pre heating warm mist Button E is used for switching the pre heating on and off symbol I lights up As a result the water is pre heated to a temperature of 176 F 80 C before entering the nebulizer space It takes approx 10 to 15 minutes for the water in the base to warm up The mist now leaves the humidifier at a pleasant temperature of 104 F 40 C The advantage of this is that the room temperature does not drop and in addition it significantly improves the water quality maintenance F Automatic mode and Sleep mode The automatic and sleep modes can be activated by pres sing button F By pressing the button once the automatic function is switched on symbol J appears on the display maintaining the optimum humidity subject to the tempera ture Control takes place by means of output quantity and pre set target value By pressing the button twice the sleep function is switched on symbol K appears on the display the target humidity is 50 65 the operation time is set at 6 hours and the heating is switched on In addition the output quantity is also controlled subject to the difference between the target value and the actual value The hygrostat and mist output settings cannot be changed in either mode If the buttons B or D are pressed the unit will no longer be in auto or sleep mode G Timer Indicator H Mist Output In
4. is now flowing through the demineralization cartridge Wait for 15 minutes to allow the mist to come out of the unit If the unit is not working and the empty light is not flashing you might have set the desired humidity too low and the current humidity level in the room is hig her That is why the unit switches off automatically If the empty indicator keeps flashing and the tank is full the water is not flowing through the cartridge Exchange the cartridge or the granules in the cartridge after 2 3 months in areas with hard water exchange the cartridge after 1 2 months However the demi neralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore If the granules are new see the following instructions Make sure the cartridge and or granules were soaked for 24 hours dry granules take even longer for water to filter through the cartridge and into the base Next please remove 2 tablespoons of granules from the cartridge and throw them away When there are too many granules in the cartridge it does not allow water to flow from the tank to the base a Q Water tank cap is too tight to unscrew A This could be a cause of the air pressure within the water tank Depress the spring on the bottom of the water tank cap to release air from the water tank Continue to do this until you are able to unscrew the water tank cap Q Unit is running inte
5. a sample packet of EZCal included in the packaging of your humidifier EZCal is used for cleaning and descaling any of the AIR O SWISS humidifiers and cleans mineral build up EZCal is the only recommen ded cleaning and descaling solution Do NOT use any other cleaning solutions since it can damage the pro duct Any use of cleaning solutions apart from EZCal will void the warranty Instructions for using are on the packet Only use 1 packet for 320z of water Do not change the ratio It can also be used for other humi difier brands Thorougly rinse the base with potable water and make sure no EZCal residues remain in the base EZCal is available at selected retail stores and online www airoswiss net www sylvane com 1 800 934 9194 www sylvane com 1 800 934 9194 www sylvane com 1 800 934 9194 LASTONGROUP Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland
6. ake sure that the water you are using is untreated If the water flows through a decalcification system such as an ion exchanger sodium is added to remove calcium in the building before it is used in the humidifier salt can pre cipitate as white dust around the device The demineralization cartridge or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore Option A replace the granules e Remove the water tank from the base and unscrew the water tank cap 30 The demineralization cartridge is attached to the tank cap Unscrew the cartridge from the cap by turning it counter clockwise 31 Important do NOT dispose of the water tank cap e Open the cartridge 32 e Throw the content into the waste Attention Disposed granules can make the floor slippery 33 Place the enclosed pink styrofoam piece in the center of the cartridge Do not push it to the bottom as it will be difficult to remove afterwards 34 Pour the contents of one refill granules bag into the plastic cup that is included with the refill granules pa ckaging 35 Place the empty cartridge with the plug in the center onto the plastic cup 36 www sylvane com 1 800 934 9194 e Turn the plastic cup and cartridge over and shake until all granules are in the cartridge 37 e Remove the plastic cup and the pink styrofoam piece from the cartridge 38 and retain for future use the refill gr
7. anules consists of 3 refill bags 39 e Close the cartridge 40 e Soak the demineralization cartridge in a water bath 24 hours before using it 43 The granules have to ab sorb water to reach high performance If the cartridge is soaked in the tank make sure to exchange the water and empty the water from the base before using the humidifier e Screw the cartridge on the water tank cap 44 e Screw the cartridge on the bottom side of the water tank put the tank on the main body 45 Placing granules in the center of the cartridge A allows them to escape in the unit or to clog the unit The unit will no longer operate properly and the granules need to be cleaned out thoroughly Option B replace the whole cartridge e Remove the water tank from the base and unscrew the water tank cap 30 e The demineralization cartridge is attached to the tank cap Unscrew the cartridge from the cap by turning it counter clockwise 31 Important do NOT dispose of the water tank cap e Throw the whole cartridge into the waste 41 e Unpack the new cartridge 42 e Soak the demineralization cartridge in a water bath 24 hours before using it 43 The granules have to ab sorb water to reach high performance If the cartridge is soaked in the tank make sure to exchange the water and empty the water from the base before using the humidifier e Screw the cartridge on the water tank cap 44 Close tank cap well and place the tank on the mai
8. ase Rinse the base with hot clean water Do not submerge the base Visually inspect the base for dirt or mineral build up If soft water is used decalcifying the unit every 4 weeks with EZ Cal is suggested If hard water is used the unit should be decalcified every 2 weeks Do not forget to reset the clean light after reset ting the unit www sylvane com 1 800 934 9194 Q Reset cleaning light digital models A The cleaning light does not automatically reset Hold down the power button button A in instruction manual until the light stops flashing The light automatically comes on approx after 14 days of plugging in the unit Q The hygrometer on unit reads a different humidity level than external hygrometer A Not all hygrometers are calibrated the same and most are off by 5 Plus the humidity level is not the same in the whole room The air circulation is different in every corner of the room The unit should not be placed near a heating vent or a radiator as the heat will absorb all of the moisture Q Humidity level is not changing or does not reach the desired humidity level A If the water tank needs refilling more than once per day the unit is working properly and the climatic con dition in the room has an influence on the humidity Reasons for low humidity level e air circulation is very high air is fully exchanged se veral times per day the humidifier needs to starts its work from scratch e insulation
9. ast longer The cartridge must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore See Replacement of the demineralization cartridge Read the instructions under Filling the Tank for adding water in the humidifier 14 and 15 Place the water tank onto the base Insert the plug into the socket and switch on the appliance using the on off dial 18 and 19 About 10 to 15 minutes after it is switched on the de vice will reach its full output level Make sure that the cable is not pinched anywhere 9 Do not operate the humidifier if the cable is damaged 2 Filling the tank Always unplug the unit before removing the A water tank Do not touch the water in the base during operation Do not operate the humidifier when the water tank is empty When the water reaches the minimum level the unit switches off the nebulizer function automatically The empty indicator light comes on showing tank is empty e Remove the water tank from the base and unscrew the water tank cap 14 Make sure that no foreign objects are in the water tank Fill the tank with clean cold water from the tap 15 Close the cap of the water tank securely place the wa ter tank onto the base 16 The water is now running from the tank into the base Do not pour water into the mist outlet of the appliance 17 Insert the plug into the socket
10. at to do Unit does not operate Power cable not plugged in Plug in power cable No water in the tank Empty indicator on Fill tank with water and wait 10 min No mist output Unit needs cleaning Descale the water base using EZCal Demineralization cartridge exhausted Replace cartridge or granules Demineralization cartridge overfilled with granules Take out 2 tablespoons of granules and throw them away Weak mist output Water temperature too low Set mist output to maximum after 15 min the humidifier will work properly again Mineral deposits on membrane Clean membrane using EZCal and brush Unit running intermittently White dust around the humidifier Demineralization cartridge exhausted Replace demineralization cartridge or granules when used with pre heating to 176 F 80 C General Humidifier Questions Q A Why isn t there enough moisture in my room How often do you run the unit If the unit is only run at night then during the day the moisture level will drop if moisture is not constantly added to the air Do you leave your door open or closed when the unit is running a By leaving the door open this allows moisture to leave the room and go into other areas of the house If you would like the moisture to stay within one specific room you should consider closing the door while the unit is running b Wood leather carpet curtains and othe
11. dicator I Pre heating Indicator J Automatic Mode Indicator K Sleep Mode Indicator L Empty indicator The water level is easy to see thanks to the transparent water tank The appliance also alerts you when the water tank is empty The empty indicator is illuminated symbol L Please read the chapter Filling the tank for more informa tion The symbol L may stay illuminated for some seconds with a refilled tank until the base is filled with water M Cleaning indicator If symbol M CLEAN appears on the display the appliance should be cleaned as recommended by the manufacturer This symbol comes on automatically every 2 weeks de pending on the level of use The display can be reset by holding down button A until the light disappears z Cleaning Maintenance Always unplug the unit before removing the A water tank Do not touch the water in the base during operation Caution risk of electric shock and damage of the product e Switch off the appliance 20 and unplug it from the socket before cleaning it 21 e Clean the water tank and the base regularly Use water only no detergents 22 e Use AIR O SWISS EZCal custom cleaning and descaling agent only to remove deposits from the membrane re gularly 23 There is a sample of EZCal included in the packaging of your humidifier Instructions for using are on the packet Only use 1 packet for 32 07 of water Do not change the ratio Do NOT run the unit
12. er between outside and inside temperatures more humidification is needed because of the dry air in the room Q Where should I place my humidifier A The unit should be free standing and not close to a wall window door or thermal bridge so that air may circulate around the unit Ultrasonic Frequent Questions Q Why does it say open close on the demineralization cartridge cap A Those directions are there in case you decide to use the refill option to replace the granules the purpose is for how to open and close the cap If you did open the cap before placing it in the water tank you will most likely notice that there are granules in the water tank and the base of the unit Immediately turn off the unit and empty the water out of the base and the water tank Begin removing all granules from base and water tank Use brush to clean around membrane Caution Do not dispose of granules in sink Used granules must go in waste Q I just replaced my cartridge and the contents and water in the base has turned a blue green color A This sometimes occurs when the cartridge or even the granules are replaced This does not occur with all replacement cartridges or granules and is a reaction of water content and the Ultrasonic vibrations This is not an indicator to replace the cartridge Q A There is no fill line on the water tank how far may I fill it up There is no fill line on the water tank and it may be filled al
13. er level is easy to see thanks to the transparent water tank The appliance also alerts you when the wa ter tank is empty The red empty indicator is illuminated symbol C Please read the chapter Filling the tank for more information The red symbol C may stay illuminated for some seconds with a refilled tank until the base is filled with water Operation AOS 7147 0 0 O A On Off Dial You can switch the unit on or off by pressing button A This button is also used to reset the cleaning indicator light by holding down B Hygrostat setting the humidity level By pressing button B you can set the desired humidity level from 30 to 80 or CO continuous operation A relative humidity between 40 and 60 is recommended The ac curacy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting During selection the target value is displayed symbol DESIRED The display will automatically show the current value after a few seconds symbol CURRENT C Timer Using button C the operation time can be set adjusta ble between 1 and 8 hours or CO continuous operation Symbol G shows the operating period that has been set 1h 2h 8h 4h 5h 6h 7h 8h CO The display will automati cally show the current humidity after a few seconds www sylvane com 1 800 934 9194 D Mist output regulating mist output By repeatedly pressing button D you can control the mist output Symbol
14. f silver to prevent the growth of microbes in the water base It begins to function as soon as it comes into contact with water even if the unit is switched off The lonic Silver Stick should be changed every year Look at picture 28 for the position of the ISS in the base part of the unit Do not touch the water in the base during operation Switch off the unit first Contact your local retailer or check our website www airoswiss net for reorder information The lonic Silver Stick comes with a metallic clip which can be removed for the placement in this product type www sylvane com 1 800 934 9194 Lifecycle Indicator Your appliance comes with a lifecycle indicator for changing the lonic Silver Stick To remind yourself of when you put the ISS into operation please cross the current month on the stamp and write the current year on the line provided 29 Replacement of the demineralization cartridge Always unplug the unit before removing the A water tank Do not touch the water in the base during operation The water tank is equipped with a demineralization cart ridge This cartridge has to be replaced every 2 3 months If the water is very hard it may be necessary to replace the cartridge earlier White dust around the device is a sure sign that the cartridge needs replacing If white residue still forms around the device after a new cartridge has been inserted please m
15. ier will auto matically switch on As soon as the desired humidity level is reached it will switch off Description of the appliance LETS SAS Evaporation chamber Demineralization cartridge Water tank cap lonic Silver Stick Control panel Main body www sylvane com 1 800 934 9194 Mist outlet rotating Water tank Brush Membrane Nebulizer space Power Plug Setting up Fin e ding the ideal location for your unit Do not place the humidifier directiy next to a heating vent or on a floor with floor heating The moisture of the mist can damage the floor surface 6 see Safety Instructions The unit should be placed in an elevated position 7 e g on a table chest etc at least 3 ft off the floor The mist outlet must not be pointed directly at plants furniture or other objects 12 Keep distance of at least 20 inches 50cm Soak the demineralization cartridge in a water bath 24 hours before using it 13 The granules have to ab sorb water to reach high performance If the cartridge is soaked in the tank make sure to exchange the water and empty the water from the base before using the humidifier www sylvane com 1 800 934 9194 On average the demineralization cartridge should be replaced every 2 3 months depending on your water hardness Some areas may need to replace the cart ridge sooner some may l
16. ing or wood floor surrounding the unit may become damp If the unit is z placed at least 3 feet off the floor the mist will have the opportunity to evaporate before hitting the floor Water does not go into the tank In order to fill the tank it must be turned upside down The cartridge is placed on the water tank cap Do not pour water in the tube which is the mist outlet White dust is emitted from the unit White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process Solve the problem Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours If the cartridge is soaked in the water tank the water in the tank and the base needs to be replaced before using the unit Exchange the demineralization cartridge after 1 2 months when you use very hard water for softer water after 2 3 months No matter how hard your water is exchange the cartridge at the very latest after 6 months Don t use water from a pre installed water softener or sodium instead of calcium will be emitted from the unit Use distilled water instead and remove the demi neralization cartridge For very hard water areas use only distilled water and remove the demineralization cartridge Use Reverse Osmosis water R O water instead of distilled water and remove the demineralization cart ridge Cleaning light is illuminated digital models Switch off the unit and unplug it Empty the water in the b
17. l the way to the top What is the purpose of the demineralization cart ridge DMC 2 The DMC removes minerals from the water to prevent white dust The contents of the cartridge need to be so aked for 24 hrs prior to first using the unit so that they may fully expand and remove minerals from the water The contents of the DMC have a life of 2 3 months The cartridge may need to be replaced more often depending on water hardness and how often the unit is used An indication of when the DMC needs to be changed can be white dust or reduced amount of mist output Is it ok to use distilled water with the unit For best results with your ultrasonic humidifier use distilled or reverse osmosis water and remove the demineralization cartridge I just replaced the contents of the cartridge and now have granules everywhere First make sure there are no granules in the middle of the cartridge Placing granules in the middle of the DMG allows them to escape in the unit Immediately turn off the unit and empty the water out of the base and the water tank Begin removing all granules from base and water tank Use brush to clean around membrane Caution Do not dispose of granules in sink Used granules must go in waste The directions tell me not to place the unit directly on the floor why do I have to elevate the unit The idea with this unit is to allow one to force humidity into the air Because of this the carpet
18. may cause electric shock or damage to the appliance Do not block air outlets or intakes e Do not pour water into the mist outlet of the appliance e This appliance has a polarized plug one blade is wider than the other To reduce risk of shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat this safety feature e A loose fit between the plug receptacle and the AC outlet may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn receptacles e Do not sit stand or place any heavy objects on the appliance e Do not submerge the main body in water or other liquids e Disconnect power supply before servicing e Persons who are not familiar with the instructions for use as well as children and persons under the influence of medication alcohol or drugs are not permitted to operate the appliance or are only per mitted to operate it under supervision e The use of water additives such as ethereal essential oils fragrances eucalyptus water conditioners etc damages the tank material and as a consequence the whole unit Any use of such additives will void the manufacturer s warranty e Remark Neither humans nor animals can hear the high frequency vibrations AAA www sylvane com 1 800 934 9194
19. n body 45 3 www sylvane com 1 800 934 9194 Storing the appliance for extended periods Clean the appliance as described earlier and allow to dry thoroughly Preferably store the appliance in its original box in a dry place away from high temperatures Legal notice The humidifier is cUL listed Subject to technical change The instructions for use are protected by copyright O PLASTON AG Accessories Contact your local retailer or check our website www airoswiss net for re order information Customer Service Customer Service USA 1 800 336 0326 www airoswiss net Troubleshooting Problem Possible cause www sylvane com 1 800 934 9194 Technical data AOS 7145 Technical data AOS 7147 Electrical voltage 120 V 60 Hz Electrical voltage 120 V 60 Hz Power consumption up to 45W Power consumption up to 40 W 125 W Humidity output up to 3 gallons 24 h Humidity output up to 3 5 gallons 24 h Suitable for rooms up to 600 sq ft 55 m Suitable for rooms up to 650 sq ft 60 m Dimensions LxWxH 9 5 x 10 3 x 12 2 in Dimensions LxWxH 9 5 x 10 3 x 12 2 in 24 x 26 x 31 cm 24 x 26 x 31 cm Weight empty 6 6 lbs 3 kg Weight empty 6 6 lbs 3 kg Accessories Demineralization cartridge Accessories Demineralization cartridge lonic Silver Stick lonic Silver Stick Wh
20. of home see air circulation e open space with high ceilings not only the footage of the room counts but also the height high rise buil dings require more humidification e open windows works similar to air circulation if it is very cold outside don t open the window more than 2 times per day for 3 minutes e big difference between outside temperature and inside temperature the colder the air the less moisture it is capable to hold and the more the air is heated up the lower is the percentage of relative humidity the amount of water vapor in the air compared to the amount the air could hold if it was totally saturated e position of the unit if it is placed close to a door win dow or air vent This increases the air circulation Q A Tank is leaking Check if there are any hairline cracks Dropped units or water tanks that are cracked will not be covered under the warranty Please contact the retailer the unit was purchased from in case your unit arrives damaged Placing the face in the mist It is not recommended that anybody places their face in the mist It is an electrical product and should not be played with No mist unit is not working empty indicator keeps flashing Fill up the water tank Check if water is flowing through the demineralization cartridge attached to the water tank cap If the water tank is full but there is only little water in the base it indicates that the water
21. r types of fabric soak up a lot of moisture thus not leaving enough moisture for the air If the window is left open then this allows moisture to escape the room Another factor is a lot of times the unit is placed next to a heating device The idea is that the air blowing into the room will quickly place moisture around the room Unfortunately this concept does not work because the hot air coming out of a vent will soak up most of the moisture and none of the air within the room will receive any How much moisture do need in my room Suggested humidity levels are between 40 60 What are the effects of too little or too much humidity Dry air can cause dry skin static electricity out of tune musical instruments increased levels of dust dry air causes dust to rise damage to wooden objects dry out and eventually cracks appear discomfort sick ness and dries out nasal membranes Over humidifying the air can cause mold and wallpaper to peel www sylvane com 1 800 934 9194 Q Why do need a humidifier when can just open my window A The moisture level within the outside air is not high enough to humidify a room The colder the air the less moisture it is capable to hold and the more the air is heated up the percentage of relative humidity is lower Relative humidity means the amount of water vapor in the air compared to the amount the air could hold if it was totally saturated The difference is high
22. rmittently A How long has it been since the contents of the cart ridge were replaced If 2 3 months have passed it is time to replace the contents of the cartridge However the demineralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore e If the contents of the cartridge were just replaced there are probably too many granules in the cartridge Re move 2 tablespoons of granules from the cartridge Accessories Q Do need to keep any parts before replace the demineralization cartridge A Yes always keep the water tank cap this is the piece that attaches the demineralization cartridge to the water tank Q What is the lonic Silver Stick ISS and how long is it good for A The lonic Silver Stick ISS uses the anti microbial effect of silver to prevent the growth of microbes in the water base It begins to function as soon as it comes into contact with water even if the unit is switched off The lonic Silver Stick should be changed every year Q Placement of the lonic Silver Stick A Please see picture 28 for instructions Q Replacement reminder A In each ISS box and on all the new products there is an ISS lifecycle indicator Check the box of the month z www sylvane com 1 800 934 9194 Q A when starting to use the ISS and write the year on the line indicated Exchange it after one year What is EZ Cal There is
23. vice engineers 4 Improper repair work can cause considerable danger to the user e Place the humidifier on a dry level surface 5 e Do not place the appliance directly on the floor or next to a heating vent 6 e If the mist comes in contact with the floor prior to evaporating the floor surface can become damaged We do not accept any liability for damages in the case of incorrect placement of the unit e The unit should be placed in an elevated position 7 e g on a table chest of drawers etc e Place appliance where it is not easily knocked over 8 e Always unplug when not in use e Only operate the humidifier when it is completely assembled e ALWAYS unplug before removing filling emptying the water tank before cleaning maintaining assembling dismantling of individual parts and before moving the appliance e Do not touch the water in the base during operation because of high frequency vibrations in the water e Do not run power cords under carpets and do not co ver with throw rugs Arrange cord so that it will not be tripped over e Never pull the plug from the outlet by the cable or with wet hands e Do not use the appliance where combustible gases or vapors are present e Do not expose the appliance to rain or use near water in a bathroom laundry area or other damp location e This unit must be used in its upright position e Do not allow foreign objects to enter ventilation or exhaust opening as this
24. when using EZCal This can cause damage to the product and voids the warranty Thoroughly rinse the base with potable water after using EZCal and make sure no EZCal resi dues remain in the base EZCal from AIR 0 SWISS is the only recommen ded cleaning and descaling solution Do NOT use any other cleaning solutions since it can damage the product Any use of cleaning solutions apart from EZCal will void the warranty e Make sure main body is never submerged in water 24 e AOS 7147 The cleaning indicator still appears on the display after cleaning To reset it hold down the ON OFF button until the clean light disappears e Clean the inner parts with a soft cloth Do not use any solvents or aggressive cleaning agents to clean the appliance 25 www sylvane com 1 800 934 9194 Only use the brush to clean the membrane This should be done once a week Only use the soft bristle portion of the brush 26 Change the water in the tank at least once a week if water is standing for more than a week To remove the mist outlet 27 Twist the mist outlet to either the right or the left Align the arrow on the mist outlet with the arrow on the ring around the mist outlet Only one set of arrows on mist outlet and ring will align Pull up on the mist outlet once the arrows are aligned Water quality maintenance The lonic Silver Stick ISS uses the anti microbial effect o
25. www sylvane com 1 800 934 9194 PLEASE READ AND SAVE AIPR O SWISSK ALL INSTRUCTIONS ADVANCED AIR TREATMENT SYSTEMS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES IN EYALTIMALIS www sylvane com 1 800 934 9194 www sylvane com 1 800 934 9194 Instructions for use Instructions d utilisation Instrucciones para el uso www sylvane com 1 800 934 9194 www sylvane com 1 800 934 9194 Instructions for use hl www sylvane com 1 800 934 9194 PLEASE READ AND SAVE ALL THESE INSTRUCTIONS Important safety instructions e Prior to using the appliance read through the in structions for complete use and retain in a safe place for later reference e WARNING Only use the Ultrasonic indoors and within the specified technical data Improper use can be hazardous for the health and lead to critical injury e Connect the unit only to alternating current with voltage according to the rating label e Children cannot recognize the hazards associated with the usage of electrical appliances For this reason always supervise children when they are near the humidifier image 1 e Never use the appliance if there is any damage to the appliance or cable 2 after malfunction after the appliance has been dropped 3 or damaged in any other way e Repairs of electrical appliances are only to be made by qualified ser