Home
Full Product Line Catalog - Palmer Wahl Instrumentation
Contents
1. Test and Calibration instruments CK OO Pocket Calibrators Portable Calibrators Bench Top Calibrators Process Signal Calibrator Micro Ohmmeters Soldering Iron Tester PALMER www palmerwahl com INSTRUMENTATION GROUP 03 07 Rev D Test amp Calibration Pocket Pocket Calibrators TC621 TC622 pete Measurement and Generation Rugged IP54 Construction for On Site Use Process Control Simulation Calibrators User friendly and robust the New Wahl TC621 and TC622 Pocket Calibrators are designed to simplify temperature transmitters and probes maintenance and commissioning They feature 0 02 Accuracy and measure and simulate Thermocouples or RTDs Resolution is programmable for better reading by user with up to 1MQ or 1uV FEATURES o Well adapted for different process job procedures due to their wide choice of ranges and specific functions such as scaling and ramping e High Accuracy 0 02 of Reading e Very low temperature coefficient as low as 15 ppm C in thermocouples and 10 ppm C in resistance e Accuracy is maintained even in harsh environmental conditions e Measurement and Simulation of 14 Thermocouples and 12 RTD types For a complete selection of probes please visit www palmerwahl com and click Hand Held Instruments gt RACERS RTD Meters and Probes or Thermocouple Meters amp Probes GRAPHIC INTERFACE FOR PROGRAMMING TC Series Pocket Calibrators use a graph
2. Voltage 20 ppm rdg C for Current e Accuracy is Preserved Even in Difficult Operating Conditions e Measurement up to 50V ONE YEAR e Simulation up to 15V TRACEABLE TO iL is WARRANTY e Measurement and Emission up to 25mA GRAPHIC INTERFACE FOR PROGRAMMING The P32 offers a graphic interface making programming and reading easier Operating Mode Screen Function Screen Reading Screen Switch to measurement MEASUREMENT CONFIG 10 03 2005 19 33 09 Function P T 10 03 2005 19 32 13 Range 020omA E Oma IN 0 20mA 0 00 Loop supply OFF a Predefined set points gt Scale Linear EJ 0 0 0 0 Increments Hart OFF i art ing a mA WN Measurement___s 0 000 0 000 0 000 Configuration Configuration Buy it you ll like it For complete specifications please visit www palmerwahl com and click GUARANTEED Test amp Calibration gt Calibrators Process Signal USA Customers only Calibration Services Available PA M F R Wahl 800 421 2853 FAX 828 658 0728 www palmerwahl com INSTRUMENTATION GROUP 5 03 07 Rev D Test amp Calibration WIV NMicro Ohmmeters OM16 OM21 OM22 bo VM PORTABLE MICRO OHMMETER e Low resistance value measurement in 4 wire configuration 0 140 to 25000 e Measuring current adaptable to the measuring range from 10A to 100mA e Inductive resistance measurement coils motors and trans formers e Non inductive resistance measurement of earth
3. date for its next calibration This is provided when you Why you need a buy a new product and when you return a product for calibration Most Products Wahl Calibrator for Unit is calibrated to factory specifications using your business NIST Traceable equipment Unit is provided with NIST Traceable Test Report Our quality Management system is certified e Increase customer satisfaction with consistent products TRACEABLE TO to conform to 1509001 2008 We maintain a calibration system in conformance with ANSI NCSL Z 540 and MIL STD 45662A As Received and As Left Data with Out of Tolerance conditions noted Calibration Sticker see above Improve product quality Registration is fast and easy In about a minute you can register your product for Warranty Protection and our Calibration Reminder Service to e To comply with quality standards e Ensure traceability throughout keep your QC Program in compliance Go to www palmerwahl com register your entire manufacturing Palmer Wahl offers repair and calibration services on most products process we sell Contact Customer Service for pricing and an RMA Please see note below Detailed Repair Report Available upon request this report provides details of e Integrates all the necessary func evaluation and repairs made tions for adjustment and mainte Custom Points Palmer Wahl will calibrate your instruments at your specified nance of your process temperature or pr
4. 2 or 5 ohms E wem e Output to recorder 1 mV F 100 mV mV 100 mV ohm e Transient voltage spike detector detects transients over 100 mV and 1ps pulse width e Built in thermocouple connector for Type K probes wire probe included e Function selection switch for fast tests without moving the iron tip IITE epiaceapie sensor e Auxiliary AC convenience outlet powers iron under test and insures common ground with the tester TRACEABLE TO l j ee Ty Specifications e Comprehensive Operators Handbook with calibration Temperature Range 50 F to 1300 F 10 C to 700 C Temperature Accuracy Accuracy 0 1 of reading 1 digit Resolution Resolution 0 1 F or 1 F e Wrist strap tester verifies strap integrity WARRANTY Tip Ohms Range 0 99 9 Q Tip Ohms to Ground Accuracy Accuracy 0 20 Q 0 1 Q Kits REPLACEMENT SENSORS AND ACCESSORIES T 20 100 0 5 of reading Resolution KST2200 Kit includes ST2200 Soldering Iron Tester TC800K Type K Resolution 0 01 or 0 1 Q Wire Probe 2 WST 02B Sensors TC801P Solder Pot Probe Sensor Tip mV to Ground Range mV to Tip mV to Ground Range Range Cleaning Brush User Manual NIST Certification and 12423 01 Carry Tip mV to Ground Accuracy Accuracy 0 1mV KST2203 Kit Same as KST2200 but substitute 1 WST 03 Elevated Wire Sensor for 1 WST 02B WST 03 Elevated Wire Sensor welded thermocouple wire sensor Replaceable Thermocouple Solder Bead Sensors Provide excellent support posts and glass
5. able PA M F R Wahl 800 421 2853 FAX 828 658 0728 www palmerwahl com INSTRUMENTATION GROUP 3 Calibrators Temperature gt Portable Calibrators 03 07 Rev D 4 Test amp Calibration Bench Top Calibrator PJ6301 Bench Top Calibrator Tester This product had been Discontinued The PJ6301 calibrator tester is a high accuracy instrument 0 005 with 600 000 measuring counts on voltage and current ranges 0 05 C for thermocouple and 0 005 C for RTD measurement resolution e 50 ppm Accuracy o Simultaneous Input and Output e DC Voltage Current Resistance Temperature Sensors RTD amp T C e R 232 IEEE488 2 Programmable e Menu Driven Design for Easy Use The model PJ6301 calibrator tester measures and simulates process Signals Its design incorporates out Standing performance with either manual configuration or computer operation for automatic test applica tion Comprehensive PJ6301 measures and generates or simu lates process signals such as DC voltages and currents resistance and temperature signals from thermocouple or RTD sensors Separated circuits allow simultaneous and independent measurement and sourcing lts graphic display is divided into two areas for simultaneous indication of measured and emitted values Other functions Such as data processing customized signal linearization recorder analog output transmitter function ramp and step function relative measuremen
6. atories also suitable for Instrument Maintenance and Approval companies e Energy Electrical Gas Oil etc e Heavy Industry Steel Work Metallurgy Chemical Glass Cement etc e Textile Paper Wood Rubber Industries e Food Industry e Pharmaceutical Industry e Advanced Technology Industry Aerospace Military Transportation etc Scientific Research Calibration Services Available 800 421 2853 FAX 828 658 0728 www palmerwahl com 03 07 Rev D Test amp Calibration Process Signal Pocket Calibrator PAKNE EN P32 Pocket Calibrator Simple and robust this instrument is designed to simplify maintenance operations and commissioning of sensors and transmitters using process signals such as 4 20 mA or 0 10V The Wahl P32 Process Signal Pocket Calibrator has been designed with increased performance in order to meet the demands of today s higher accuracy transmitters and process sensors Accuracy of 0 015 of reading allows the P32 to be used as a standard for on site operations The P32 features adjustable display resolution to simplify measurements with maximum resolutions of 1 pA and 1mV FEATURES e Measurement and Simulation o Rugged IP54 Construction for On Site Use e Quick Connect Terminals with 4mm Banana Plugs e User Selectable Ranges and Scaling Provide Versatility for All Your Process Measurement Tasks e High Precision 150 ppm of Reading e Low Temperature Coefficients 15 ppm rdg C for
7. bonding coat ing contact resistances OM16 Micro Ohmmeter is designed for outdoor or indoor use Easy to use it performs measurements on inductive and non inductive resistances with a DC current Its large interactive display informs the operator in real time about the type of measurement range calculation conditions resistance calculated according to a reference temperature thresholds status and values Designed for harsh environments it is encased in a Pelicase type carrying case and features washable plastic keyboard and key locked measure ment plugs BencH Top MicrRo OHMMETERS e Programmable e Four wire resistance measurement of very low values STITT RES e Resolution of 0 1 to 20kQ om ea 5 E gS Jn AA e Accuracy of 0 03 and a display over 26 000 counts TO TFF e Display of the measured resistance value reduced to 20 C e Mains supply or rechargeable batteries OM16 Previously RM116 0M21 OM21 Micro Ohmmeter can be used for measurement of thermistors and heat sensitive components It can be powered from mains or from rechargeable batteries The instrument is calibrated electronically with no internal adjustment needed OM22 Micro Ohmmeter is specifically designed for industrial test and pre configured for each user making its principal characteristic sim plicity of operation User selects one of 6 test programs Factory Pre sets or User Programmable to find the desired configuration The ins
8. c design and embedded software make them e Quick Connect Terminals easy to use high performance calibrators e Measure and Generate Voltage Current and IP 54 rated and fully protected by an anti shock boot with Resistance Signals integrated quick connect terminals and a high contrast e Temperature by Resistive Probes and Thermocouples backlit display they are comfortable to use in all conditions e Frequency for Frequency Signals and for Dry Contacts C Series Calibrators are supplied with 6 testing leads with crocodile clips quick battery charging system neck strap C75 FEATURES and stand for desktop use User Manual on CD Rom attache style f py j Ml like it e Pressure Measurements when used with optional External professional carrying case and Pressure Module for Absolute or Relative Pressure NIST Calibration Certificate UARANTEED USA Customers only C100 ADDITIONAL FEATURES C150 ADDITIONAL FEATURES PLUS e Pressure Measurements when used with optional External e Pressure Measurements when used with optional External Pressure Module for Absolute or Relative Pressure Pressure Module for Absolute or Relative Pressure e Laboratory Grade Accuracy o 0 005 Accuracy over 1 year TERT e Software HART Compatible For complete specifications please visit www palmerwahl com and click Test amp Calibration gt e Measurement and Simulation of Thermistances o Dual Input Thermometer IN and OUT or IN IN Calibration Services Avail
9. ent which can cause temperature fluctuations WST 02RT Repair tool kit for use with WST 02 02B Rebuilding Kits Includes fixture removal tool and screwdriver 12423 01 Carrying Case Double walled Foam lined 17 x 13 x 7 3 8 i TC867 Sensor Assembly for direct tempera Elevated Wire ture measurement only from a Heat Prober Thermocouple Meter For Optional Probes please call Customer Service WST 02 Solder Bead Sensor WST 02B Bonnet Sensor WST 03 Elevated Wire Sensor WAN 4 Wahl 800 421 2853 FAX 828 658 0728 www palmerwahl com INSTRUMENTATION GROUP 03 07 Rev D INSTRUMENTATION GROUP America s First Manufacturer of Precision Industrial Temperature and Pressure Instrumentation CALIBRATION SERVICES Wahl designs and manufactures to the most stringent quality standards We provide certified traceable calibration data in support of companies whose requirements include meeting ISO 9001 FAA and FDA quality standards Calibrations to both IPTS 68 and ITS 90 are available Choose from two levels of calibrations services to meet your quality system requirements Unit is calibrated to factory specifications using NIST traceable equipment Unit is provided with Certificate of Conformance Statement that our product meets published specifications Included when you buy a new product Calibration Sticker or tag Advising you of the date your instrument s was were calibrated and the suggested
10. essure Special Requests When calibrating your instrument our experienced personnel o Our products are easy to use and will help you to achieve the level of quality that you need in your facility Palmer Wahl is there to help Note You must have a Return Merchandise Authorization Number RMA before returning a product for repair or calibration To obtain an RMA please call Customer service at 1 800 421 2853 or go to www palmerwahl com and click on service gt Product Return Request oi www palmerwahl com Wahl Test amp Calibration products are distributed by Palmer Wahl Warranty Manufacturer warrants all products listed in this catalog to be free from defects in material or workmanship under normal use and Service The Manufacturer agrees to repair or replace any product which upon examination is revealed to have been defective due to faulty workmanship or material if returned to our factory transporta tion charges prepaid within the product specific warranty period stat ed in the catalog by the manufacturer This warranty is in lieu of all other warranties expressed or implied and of all obligations or liabil ities on its part for damages including but not limited to consequen tial damages following the use or misuse of instruments sold by the Manufacturer No agent is authorized to assume for manufacturer any liability except as set forth above every step of the way 234 Old Weaverville Road Asheville Nort
11. filled teflon body May be used when the iron thermal transfer when the solder is melted by the iron and gives a good _ tip is not compatible with the WST 02 sensors Allows the operator to instructions and troubleshooting guide THREE YEAR e ESD safe construction 3 representation of effective working tip temperature measure temperature at an exact point on the iron tip For all tip sizes WST 02 Sensor high temperature Type K ribbon thermocouple Sensor Rebuilding Kits allows user to rebuild the sensor Stainless steel support strap solder bead and glass filled teflon body WST O2KIT Rebuilding Kit for use with WST 02 Sensor includes housing Measures tip temperature of most small lt 1 8 conical 1 Sensor 4 Screws 2 Plugs and Instruction Sheet chisel and screwdriver type soldering tips shown on tester above WST 02BKIT Rebuilding Kit for use with WST 02B Sensor includes Heavy duty sensor Small to medium tips 0 2 gram mass 1 Sensor 4 Screws 2 Plugs and Instruction Sheet WST 02B Bonnet Sensor Same as above but with a bonnet which WST 03KIT Rebuilding Kit for use with WST 03 Sensor includes acts as a position stop to guide iron tips for repeatable measurements 1 Sensors with supports 4 Screws Uses standard phillips head in the identical position It also stabilizes the tip to prevent movement screwdriver Teflon body or housing is not included in rebuilding kits during measurem
12. h Carolina e 28804 1260 Phone 828 658 3131 Toll Free 800 421 2853 Fax 828 658 0728 Email info palmerwahl com www palmerwahl com 1 09001 2008 Certified Quality Management System PW1210 03 07 Rev D Digital version of catalog may differ from printed version
13. ic interface making programming and reading easier Function Menu Operating Menu Reading Menu Parameterize measuring function 23 01 2006 11 30 06 23 01 2006 11 30 51 bes IN K Jr 0 0 C WEE fi ale Arrows Predefined set points Increments Calibrated sensors Single ramp Setup Maintenance daca 05 Aan 18 60 20 21 _ 20 55 Configuration Configuration Mode Buy it you ll like it For complete specifications please visit www palmerwahl com and click GUARANTEED Test amp Calibration gt Calibrators Temperature gt Pocket Calibrators USA Customers only PA L M F R Wahl Calibration Services Available 2 INSTRUMENTATION GROUP 800 421 2853 FAX 828 658 0728 www palmerwahl com 03 07 Rev D Test amp Calibration Portable Portable Calibrators C50 C75 e C100 C150 Superior Accuracy as compared to Competitors Calibrators Ergonomic design and embedded software make these on site multifunction calibrators an easy to use high performance tool Alphanumeric Keyboard Navigator p Power Supply USB Connectors TRACEABLE TO ee owe w E Wide backlit Screen Protected by a Polycarbonate Membrane C SERIES FEATURES FOR ALL MODELS The new Wahl C50 C75 and C100 Calibrators integrate all the necessary functions for calibration and maintenance of e Simultaneous Measurement and Generation processes e Rugged IP54 Construction for On Site Use Their ergonomi
14. trument is calibrated electronically with no internal adjustment needed RS232 IEEE 488 programmable PC software allows programming of the OM21 or OM22 from a compatible PC Menu driven completely guided by a question and answer system Second function of the software is to manipulate For complete specifications please visit the stored readings transfer into the PC memory or onto a disk in www palmerwah com and click a file which can be used for spreadsheets tables or graphs PA L M F R Wahi Calibration Services Available INSTRUMENTATION GROUP 800 421 2853 FAX 828 658 0728 www palmerwahl com Test amp Calibration gt Micro Ohmmeters 03 07 Rev D Test amp Calibration Soldering Iron Tester ST2200 Soldering Iron Tester Precise Thermocouple Sensors Simulate Actual Solder Joints Verifies Soldering Iron Integrity Simple and Repeatable the Wahl T2200 Soldering Iron Tester gives you a choice of interchangeable sensors designed for utmost accuracy Includes TC800K Type K Wire Probe WST 02B Sensor Sensor Cleaning Brush User Manual and NIST Certification specify F or C 110 or 220 VAC North American or European Plug and Receptacle or British Plug and European Receptacle ST2200F 110 e MIL SPEC compliant millivolts AC only test with pass fail warning light for voltage see video at www palmerwahl com test tools php e Pass fail warning light for resistance test user selectable
15. ts etc provide a wide and ver Satile application range Ease of Use PJ6301 is offered in a compact housing for use on site and may be bench top or panel mounted The graphic display design allows for simplified keyboard func tions On line help messages are available at any time when additional information for displayed options is required Programmable PJ6301 is fully programmable via its RS232 and IEEE488 2 interfaces With rack mounting accessory it is ideal in test bench and automatic test equipment applica tions In addition the battery and memory storage capacity make the PJ6301 portable and suitable for on site use FEATURES AND APPLICATIONS e Accurate measurement for calibration of signal generators such as sensors voltage and current sources resistance and for checking process control instruments e Temperature simulation voltage and current sourcing resistance simulation for calibration of measuring equip ment such as chart recorders logic controllers PLC analog inputs e Test of signal conditioners or transmitters using PJ6301 Simultaneous sensor simulation and output signal measurement capability For complete specifications please visit www palmerwahl com and click Test amp Calibration gt Calibrators Temperature gt Bench Top Calibrators a Wahl INSTRUMENTATION GROUP Applications include e Engineering departments e Quality Control departments e Research and Development Labor
Download Pdf Manuals
Related Search
Related Contents
DT2009-0600 - Manual de usuario - NNTT UCH APPLICATION This Paraffin Dispenser is designed for melting Manual de Usuario Verbatim Micro SDHC 8GB - Class 6 Page 1 Page 2 Page 3 Page 4 はつぱい ち積う し ょう (別売りノ発売中 Istruzioni d`Uso - Audio-luci Easy development software from the company that knows MCU Speed 20 - Mode d`emploi MANUEL D`UTILISATION Débroussailleuses Copyright © All rights reserved.