Home
ColorBurst 6 User Guide
Contents
1. DMX IN port on the power data supply 3 Connect power to the power data supply 4 Use Zapi to set the light addresses All ColorBurst 6 fixtures con nected to the power data supply are addressed simultaneously NOTE If you are using SAS you must input each serial number address separately 5 Disconnect the DMX interface Installing the Power Data Supply Following the Layout Plan install the power data supply according to state and local codes Refer to the PDS 150e or PDS 60 24V Installation Guides for complete instructions Making Electrical Connections to the Power Data Supply After installing the power data supply make the electrical connec tions to it 1 Pull the 3 conductor cable from the optional base or the 18 AWG 3 conductor stranded wire cable from the junction box to the power data supply When using the ColorBurst base pull the base cable from the fixture location to the data power supply 2 Pull the cable through the knock outs in the side of the power data supply 3 Wire the red white and black wires of each fixture to a provid ed connector then snap connectors into the connector terminals located in the power data supply See Fig 2 Fig 2 ei om 24V Connecting Power Follow the instructions in the PDS 150e or PDS 60 Installation Guide to connect from a 100 to 240VAC power source BLACK WHITE RED WARNING Ensure that power is off before
2. Use a PC with iPlayer 2 or a PC with Smart Jack 3 to address the fixtures Download SAS and instructions from www colorkinetics com support downloads NOTE For applications using multiple daisy chained power supplies you can address alll lights in the chain by attaching Zapi to the first power supply in the series NOTE Multi power supply setups are ideal for pre and postinstalla tion For post installation addressing record all serial numbers and layout positions prior to installation Setting Individual Addresses Using the Serial Number mode of Zapi 1 5 or SAS address each fixture attached to a power supply or a series of connected power supplies individually 1 With power disconnected connect up to six ColorBurst 6 to the power data supply 2 Attach the DMX interface Zapi iPlayer 2 or Smart Jack 3 to the DMX IN port on the power data supply 3 Connect power to the power data supply 4 Use Zapi or SAS to set the light address of each fixture 5 Disconnect power and then disconnect the addressed ColorBurst 6 fixture s 6 Repeat steps 1 through 5 for all remaining fixtures 7 After all fixtures are addressed disconnect the DMX interface Setting the Same Address to Multiple Lights Using Zapi 1 5 address all fixtures attached to a power supply or multiple daily chained power supplies 1 With power disconnected connect up to six ColorBurst 6 fixtures to the power data supply 2 Attach the Zapi to the
3. electrical connections to the power data supply 5 Install ColorBurst 6 fixtures Recording Serial Numbers 1 As you unpack the fixtures record the serial numbers Each ColorBurst 6 has a unique serial number programmed at the time of manufacture 2 Write the serial numbers onto a Mapping Grid or use a bar code scanner along with Color Kinetics Serial Addressing Software SAS to record each serial number SAS and instructions are located at www colorkinetics com support downloads 3 Using the Layout Plan assign the fixture to a layout position in the installation 4 Using a weatherproof label identify the fixtures installation posi tion based on the Layout Plan Place the identifying label in an inconspicuous location noting the order or placement in the instal lation This step not only minimizes installation mistakes but aids in postinstallation light show programming Addressing the Lights IMPORTANT Before you begin the installation consider the scope of your lighting application and installation Your ColorBurst 6 is set to DMX address one 1 at the factory If your application requires other addresses set the DMX addresses before installing ColorBurst 6 using one of the following addressing tools ZAPI Use Color Kinetics Zapi to set the DMX address for each fixture or set all fixtures to the same DMX address Refer to the Zapi User Guide for step by step addressing instructions SAS SERIAL ADDRESSING SOFTWARE
4. world brought to you by Color Kinetics Chromacore our patented core technology generates and controls millions of colors and a variety of lighting effects using a microprocessor to control LEDs This User Guide contains important information about installing and operating your new ColorBurst 6 fixture safely Fig 1 FRONT VIEW SIDE VIEW ACCESSORY RING gt df ATTACHMENT ACCESSORY RING E L LOCKING PIVOTS ColorBurst 6 Fixture Included in This Box e ColorBurst 6 with accessory attachment ring e 1 Accessory attachment spring e 4 Screws Phillips 8 32 standard with color matched screw caps for indoor junction box installations e 4 Screws Phillips pan head 10 24 stainless steel for outdoor junction box installations e 1 Gasket for outdoor junction box installations e Hex key wrench e User Guide Additional Items Needed e A Electrical junction box rated for your application with 3 5 inch center to center mounting or ColorBurst base Item 116 000005 for indoor applications e 18AWG 3 conductor stranded wire cable when not using base e Wire nuts e 24VDC power supply PDS 150e Item 109 000008 01 or PDS 60 24V Item 109 000017 00 03 e Controller Color Kinetics DMX Controller or DMX compatible e Color Kinetics Zapi Item 103 000005 00 US 103 000005 01 EU or Serial Addressing Software SAS Scope of This Us
5. COLORBURST 6 USER GUIDE COLOR KINETICS INCORPORATED 10 MILK STREET SUITE 1100 BOSTON MA 02108 USA TEL 888 FULL RGB TEL 617 423 9999 FAX 617 423 9998 INFO COLORKINETICS COM CHROMACORE BY COLOR KINETICS OPTIBIN BY COLOR KINETICS WWwW COLORKINETICS COM ITEM 116 000014 00 White Frosted 116 000014 01 Black Frosted This product is protected by one or more of the following U S Patents 116 000014 02 White Clear 116 000014 03 Black Clear Base 116 000005 00 White and their foreign counterparts 6 016 038 6 150 774 6 292 901 6 340 868 6 777 891 6 788 011 6 806 659 6 969 954 and 116 000005 01 Black 6 975 079 Other patents pending Uy us 2003 2007 Color Kinetics Incorporated All rights reserved LISTED Chromacore Chromasic CK the CK logo Color Kinetics the Color 78GF Kinetics logo Color Kinetics The Leader in Intelligent Light ColorBlast ColorBlaze ColorBurst ColorCast ColorPlay ColorScape DIMand Direct Light EssentialWhite eW iColor iColor Cove IntelliWhite iW iPlayer Light Without Limits Optibin Powercore QuickPlay Sauce the Sauce logo and Smartjuice are either registered trademarks or trademarks of Color Kinetics Incorporated in the United States and or other countries PUB 000141 00 Rev 02 Specifications subject to change without notice Refer to www colorkinetics com for the most recent version INTRODUCTION Welcome to a more colorful
6. MX512 RS485 compatible when using Color Kinetics power data supply POWER REQUIREMENT 24VDC POWER CONSUMPTION 25W Max at full intensity full RGB POWER SUPPLY PDS 150e Maximum of six fixtures per supply PDS 60 24V Maximum of two fixtures per supply TEMPERATURE RANGE 40 F to 122 F 40 C to 50 C operating temperature A F to 122 F 20 C to 50 C starting temperature LED SOURCE LIFE In traditional lamp sources lifetime is defined as the point at which 50 of the lamps fail This is also termed Mean Time Between Failure MTBF LEDs are semiconductor devices and have a much longer MTBF than conventional sources However MTBF is not the only consideration in determining useful life Color Kinetics uses the concept of useful light output for rating source lifetimes Like traditional sources LED output degrades over time lumen depreciation and this is the metric for SSL lifetime LED lumen depreciation is affected by numerous environmental conditions such as ambient temperature humidity and ventilation Lumen depreciation is also affected by means of control thermal management current levels and a host of other electrical design considerations Color Kinetics systems are expertly engineered to optimize LED life when used under normal operating conditions Lumen depreciation information is based on LED manufacturers source life data as well as other third party testing Low temperatures and controlled effects have a be
7. er Guide The goal of this user guide is to explain in an easily understood lan guage the necessary steps to install ColorBurst 6 and assure peak performance Its intended use is for reference only by persons who are fully qualified This document should never be considered a substitute for any provisions of a regulation or state and or local code Identification and Warnings of Safety Hazards In accordance with ANSI Z535 4 the following system of identifying the severity of the hazards associated with the products is used DANGER I mminently hazardous situation which if not avoided will result in death or serious injury WARNING Potentially hazardous situation that if not avoided could result in death or serious injury CAUTION Potentially hazardous situation that if not avoided may result in minor or moderate injury or property damage DANGER Ensure that the main power supply is off before install ing or wiring ColorBurst 6 and the power data supply Failure to adhere to these instructions will result in death or serious injury WARNING ColorBurst 6 and the power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes Failure to comply can result in death serious injury or property damage WARNING Do not attempt to install or use ColorBurst 6 or the power data supply until you read and understand the installation instructions and safety labels Failure
8. neficial effect on lumen depreciation Overall system lifetime could vary substantially based on usage and the environment in which the system is installed Temperature and effects will affect lifetime Color Kinetics rates product lifetime using lumen depreciation to 50 of original light output When the fixture is running at room temperature using a color wash effect the range of lifetime is in the range of 80 000 100 000 hours This is LED manufacturers test data High output is defined as any LED device that is 1 2 watt or above For more detailed information on source life please see www colorkinetics com lifetime WARRANTY This product is sold pursuant to CK s Standard Terms and Conditions the T amp Cs which may be found at http colorkinetics com howtobuy buy terms and which contain important provisions including among others Limited Warranty exclusions and limita tions on CK s liability for damages and restrictions on the remedies that are available fo you
9. oup of lights in direct view However ne more than one strobe light is used the flashes should be synchronized End users should also consider issuing a warning alerting audience or viewers to the presence of strobe lighting Temperature Monitoring For protection from extreme temperatures ColorBurst 6 has been designed with a temperature monitoring feature If operating temperatures rise to an unsafe level a compensation circuit is riggered and the ColorBurst 6 operation is interrupted causing the lights to turn dull red After 30 minutes the lights will auto cycle and return to full intensity To prevent additional power shut downs determine the cause of the overheating and correct the problem If any problems occur during usage unplug the product immediately and call or email Color Kinetics Technical Support Group 1 888 FULL RGB or 617 423 9999 or support colorkinetics com 1 Guide to Health Safety and Welfare at Pop Concerts and Similar Events HMSO Publications UK COLORBURST 6 SPECIFICATIONS COLOR RANGE 16 7 million 24bit additive RGB colors continuously variable intensity output range SOURCE High intensity power LEDs BEAM ANGLE 12 clear lens 22 ground lens PACKAGING Die cast aluminum in black and white finish CONNECTORS Unified power and data cable LISTINGS UL cUL Listed CE PROTECTION RATING IP66 DATA INTERFACE Color Kinetics data interface system CONTROL Color Kinetics full line of controllers or D
10. owing e Consult an Electrical Inspector to approve all wiring plans e Refer to local and state codes for installation compliance e Create a Mapping Grid Use this grid to record serial numbers for easy reference and addressing e Create a Layout Plan drawing per Lighting Designer or Architect e Employ Color Kinetics Application Engineering Services e Get detailed wiring diagrams and additional support from http support colorkinetics com Installation Considerations When creating your installation plan consider the following e Location of power data supply in relationship to lights e The maximum accumulated cable length for all ColorBurst 6 fixtures connected to a single PDS 150e is 400 feet The maximum single cable run between PDS 150e and ColorBurst 6 is150 feet e The maximum cable length for a ColorBurst 6 fixture connected to PDS 60 is 150 feet Therefore PDS 60 must be located within 150 feet of the furthermost supported fixture e ColorBurst 6 can be installed with an optional base or with a cus tomer provided junction box e Location of fixture and method of mounting ColorBurst 6 can be installed indoors or outdoors on walls ceilings or floors Junction boxes and mounting methods vary according to location INSTALLING COLORBURST 6 Steps to a Successful Installation 1 Record serial numbers and identify fixtures as you unpack them 2 Address the fixtures 3 Install the power data supplies 4 Make
11. power data cable included with fixture PI DMX Ethernet 7 100 240VAC DMX OUT DMX IN DMX CAT5 RJ45 Controller TO m ID 24V for Accessory Controller as required H 2 100 240VAC DMX Etherneit Fig 6 Power Data Cable 18AWG 823mm CSA 3 conductor stranded copper Maximum cable run from 60W Power Data Supply to Lights 150 feet 46 m 60 foot 18 3 m PDS 60 DMX Ethernet power data cable included with fixture l Ethernet IN ColorBurst 6 with PDS 60 24V Ethernet Control Ethernet IN Ethernet Switch PC used for show authoring and show control PDS 60 DMX Ethernet Connecting the Fixtures using a Junction Box After pulling the 3 conductor stranded wire cable from the power data supply to the indoor rated junction box connect wire leads from the fixture to the junction box using medium wire nuts Connect the red wire to the 24VDC white wire to Data and black wire to Common NOTE The fixture wire leads are 6 inches long and can be trimmed as necessary The color connections must correspond to color con nections on the power data supply Indoor Junction Box Mount 1 After
12. set screws USING ACCESSORY LENSES ColorBurst 6 is designed to accommodate louvers filters and lenses with a maximum 6 inch outer diameter and up to 3 16 inch thick To install accessory louvers filters or lenses 1 Remove the three attachment screws from the fixture housing The attachment ring will separate from the fixture housing 2 A retention spring retains the accessory securely to the accessory ring Squeeze the spring to remove it from the ring 3 Place the accessory into the ring 4 Replace the spring to hold the accessory in place while reattach ing the ring to the housing 5 Align the through holes on the accessory ring with the screw holes on the fixture housing ensuring the drain features align Replace the attachment screws See Fig 10 Fig 10 N RETENTION SPRING OPTICAL ACCESSORY j ACCESSORY RING ATTACHMENT SCREWS IMPORTANT INFORMATION Strobe Warning There is some anecdotal evidence that strobe lighting may induce epileptic symp toms in certain susceptible individuals although no associated product warnings have been issued by United States government according to the Food and Drug Administration If strobe lights are used some international regulatory agencies recommend keeping flicker rates at or below four flashes per second as less of the flicker sen sitive population will then be at risk of an attack This flicker rate applies only to the overall output of any gr
13. st 6 with PDS 150e Power Data Cable 18AWG 823mm CSA 3 conductor stranded copper From PDS 150e Power Data Supply maximum accumulated length of cable run for all fixtures must not exceed 400 feet 122 m A Power data cable for junction box mount provided by third party 4 J Ws Maximum single run distance from PDS 150e 150 feet 46 m 60 foot power 18 3 m data cable included with optional mounting base Junction box not included g CAT 5 RJ45 G 8 ere 100 240VAC Data Cable HH nad Color Kinetics essceeeseeeneeseed raga Power Data supply Controller inl 2 emiener FEA C 000000285 oe oe Maximum Six ColorBurst 6 fixtures per PDS 150e Power Data supply One per terminal Note Do not daisy chain ColorBurst 6 fixtures Fig 4 60 foot 18 3 m Power Data Cable power data cable included with optional 18AWG 823mm CSA mounting base 3 conductor stranded copper Maximum cable run from 60W Power Data Supply to Lights 150 feet 46 m Color Kinetics CAT5 RI45 Controller 2 100 240VAC PDS 60 Maximum Two ColorBurst 6 fixtures per PDS 60 power data supply Fig 5 i ColorBurst 6 with PDS 60 24V DMX Control DMX IN CAT5 RI45 SP W Power Data Cable 18AWG 823mm CSA 3 conductor stranded copper Maximum cable run from 60W Power Data Supply to Lights 150 feet 46 m 60 foot 18 3 m
14. to adhere to these instructions could result in serious injury or property damage WARNING Do not use ColorBurst 6 if the power cables are dam aged Doing so can result in death serious injury and property damage CAUTION ColorBurst 6 has no serviceable parts Do not attempt to open the fixture Doing so will result in property damage and void the warranty CAUTION Do not use sharp tools near or on the fixture lens Doing so will result in property damage and void the warranty CAUTION Do not hot swap Ensure the power supply is off before connecting or disconnecting fixtures Hot swapping will result in property damage and void the warranty NOTE The instructions and precautions set forth in this user guide are not necessarily all inclusive all conceivable or relevant to all applications as Color Kinetics cannot anticipate all conceivable or unique situations Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate ColorBurst 6 in such a manner as to comply with all state and local laws ordinances regu lations and the American Standard Institution Safety Code PLANNING THE INSTALLATION The nature of a ColorBurst 6 installation requires planning to ensure a timely successful installation with minimal complications and down time Planning Suggestions When planning ColorBurst 6 installation Color Kinetics suggests doing the foll
15. wiring or connecting fixtures to the power data supply Failure to do so can result in serious injuries or death CAUTION Do not overload the power data supply Doing so will result in property damage and void the warranty NOTE Each ColorBurst 6 receives power directly from a power supply CAUTION When not using the base you must provide an 18 AWG 3 conductor stranded copper cable Failure to provide the proper cabling can result in damage to the fixture and void the warranty Installing ColorBurst 6 This fixture shall be installed by a qualified professional in accor dance with NEC and relevant local codes for Class 2 power sources WARNING Power must be off before installing ColorBurst 6 ColorBurst 6 can be installed indoors or outdoors Use an electrical junction box rated for your application for wall and ceiling mounts The ColorBurst 6 fixture can be connected using either the optional base or a junction box For details on installing the fixtures with the optional base see the ColorBurst Base Installation Guide Fig 3 shows the ColorBurst fixtures connected to the PDS 150e Fig 4 shows fixtures connected to the PDS 60 with Preprogrammed con trol Fig 5 shows fixtures connected to the PDS 60 24V with DMX control Fig 6 shows fixtures connected to the PDS 60 24V with Ethernet control Fig 3 ColorBur
16. wiring the fixtures neatly tuck the conductors into the junc tion box 2 Insert two fastening screws included with ColorBurst 6 through the holes in the canopy assembly then through the mounting holes in junction box and tighten See Fig 7 3 Cover screw heads and open canopy holes with screw caps Fig 7 _ INDOOR ELECTRICAL JUNCTION BOX 3 5 ON CENTER MOUNTING HOLES Outdoor Junction Box Mount 1 After wiring the fixtures neatly tuck the conductors into the junc tion box 2 Insert four fastening screws through the holes in the canopy assembly then through gasket into the mounting holes in junction box and tighten See Fig 8 3 Cover screw heads with screw caps Fig 8 AINCH OUTDOOR ELECTRICAL JUNCTION BOX GASKET AIMING THE FIXTURE Positioning ColorBurst 6 is simple with the dual swivel aim and lock feature See Fig 9 1 After installing and energizing the light rotate the fixture arm fo the desired position 2 Using the provided Hex key wrench tighten the locking set screw located on the base to lock the arm in place 3 Rotate the fixture and lock it into place by tightening the set screw located on the arm NOTE Each swivel provides a 350 turning radius with hard stops to prevent over rotation CAUTION Do not force hard stops to over rotate Doing so will dam age the fixture and void the warranty CAUTION Do not over tighten