1. CyberPower Reliability Quality Value Value 400E GP 600E GP 800E GP 1000E GP User s Manual K01 0000185 00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no user serviceable parts insid
2. PowerPanel Personal Edition Software Management Auto Charger Yes Auto Restart Yes USB Yes Yes 0 C to 40 C 0 to 90 non condensing 3 IEC 320 C13 320x100x140mm g h D _ o M 12V 4 5Ah x1 12V 8 5Ah x1 Power On Using Battery On Battery Low Battery Overload Windows 7 Vista XP 2000 Server 2003 Linux DEFINITIONS FOR ILLUMINATED LED INDICATORS Condition O w LED Alarm Flash Beep Twice Normal Utility Failure The UPS is providing battery power to outlets Utility Failure The UPS is providing Flash Rapid Beeping Normal battery power The rapid beeps indicate the battery will run out of power shortly Overload Occurs when connected equipment exceeds the rating of the unit On Flash Constant Tone Normal Blown Turn the UPS off and unplug at lease one piece of equipment from the UPS Check the fuse and do the replacement if necessary Turn the UPS on CYBERPOWER GREENPOWER UPS TECHNOLOGY CyberPower s Green Commitment CyberPower is dedicated to the development of green products and has adopted Green practices throughout its business including membership in Climate Savers Computing Initiative CSCI accordance with the Restriction on Hazardous Substances RoHS Waste Electrical and Electronic Equipment WEEE protocols as well as ISO 14001 and IECQ QC080000 CyberPower pledges to provide the advanced energy solution for the environment and become a
3. ccur and cause the UPS unit to shut down or the fuse blow 2 There are many factors that can affect the amount of power that your computer system will require For optimal system performance keep the load below 80 of the unit s rated capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on and off position 2 With the UPS unit off and unplugged connect the computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum paper shredder or other large electrical device into the battery power supplied outlets The power demands of these devices will overload and possibly damage the unit 3 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords 4 Depress the power switch to turn the unit on The power on indicator light will illuminate and the unit will bee
4. e except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out INSTALLING YOUR UPS SYSTEM UNPACKING The box should contain the following 1 UPS Unit x 1 2 IEC Power Cord x 1 8 USB Cable x 1 4 User Manual x 1 5 Management Software Disk x 1 OVERVIEW The Value 400E GP 600E GP 800E GP 1000E GP provides automatic voltage regulation for inconsistent utility power The Value 400E GP 600E GP 800E GP 1000E GP features 405 Joules of surge protection and provides battery backup during power outages The Value 400E GP 600E GP 800E GP 1000E GP ensures consistent power to your computer system and its included software will automatically save your open files and shut down your computer system during a utility power loss HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the battery power supplied surge outlets does not exceed the UPS unit s rated capacity 400VA 240W for Value 400E GP 600VA 360W for Value 600E GP 800VA 480W for Value 800E GP 1000VA 530W for Value 1000E GP If the rated unit capacities are exceeded an overload condition may o
5. leading eco friendly organization in the UPS industry ENERGY SAVING TECHNOLOG lt Reduce Energy Cost with GreenPower UPS Technology CyberPower s goal is not only to provide eco friendly products but also to bring the best value for consumers The advanced energy saving design improves the operating_efficiency and eliminates waste energy consumption As a result consumers will enjoy significant energy cost savings with the adoption of GreenPower UPS technology TROUBLESHOOTING Possible Cause Solution Battery not fully charged peur sien by leaving The UPS does not perform expected runtime Contact CyberPower Systems about replacement batteries at service cyberpower eu com Battery is slightly worn out The on off switch is designed to Turn the UPS off Wait 10 prevent damage by rapidly seconds and then turn the UPS turning it off and on on The unit must be connected to a 220 240V 50 60Hz outlet The unit is not connected to an AC outlet The UPS will not turn on Contact CyberPower Systems about replacement batteries at service cyberpower eu com The battery is worn out Contact CyberPower Systems at service cyberpower eu com Mechanical problem Turn the UPS off and unplug at least one piece connected equipment Unplug the power cord of the UPS then remove the fuse compartment beneath the power inlet of the UPS and replace the blown fuse with a spare one Lock the compar
6. o eo000 eo000 00000 00000 I USB Port to PC This port allows connection and communication from the USB port on the computer to the UPS unit The UPS communicates its status to the PowerPanel Personal Edition software E PLUG IN ejo 22c O gt m o E oo ooo ooo ooo eoo0000 eoo0000 eooo000 oo0o000 NOTE Only one of these two ports can be used as communication and control of the UPS unit at one time TECHNICAL SPECIFICATIONS Value 400E GP Value 600E GP Value 800E GP Value 1000E GP 400 O 80 160 265Vac 47 63Hz Auto Sensing Boost 200V Capacity VA Capacity Watts Input Voltage Range Frequency Range lt JI On Battery Output Voltage On Battery Output Frequency Transfer Time Overload Protection Simulated Sine Wave at 230Vac 10 50 60HZ 1 4ms Typical On Utility Fuse amp Internal Current Limiting On Battery Internal Current Limiting Surge Protection Lightning Surge Protection Operating Temperature Operating Relative Humidity Physical Total of UPS outlets Maximum Dimensions LxWxH Weight kg Battery Sealed Maintenance Free Lead Acid Battery TAV TARXI Typical Recharge Time 8 hours User Replaceable Yes Status Indicators Indicators Audible Alarms Communication
7. p 5 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 6 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 7 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery life BASIC OPERATION FRONT PANEL DESCRIPTION IJ i en Power On Off Switch Press the power switch to turn the UPS ON or OFF Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes REAR PANEL DESCRIPTION AC Inlet Connect to utility power through the input power cord Input Fuse The fuse provides optimal overload protection AC Outlet The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes Serial Port to PC This port allows connection and communication from the DB9 serial on the computer to the UPS unit The UPS communicates its status to the PowerPanel Personal Edition software Gi Li ojejo CI a C D e E ooo0oo0oo0o ooo0oo0oo0
8. tment back to the UPS Connect power cord then turn the UPS on Make sure that your spare fuse meets the specification Fuse is blown due to overload Outlets do not provide power to equipment Allow the unit to recharge for at Batteries are discharged acta hours Unit has been damaged by a surge or spike Contact CyberPower Systems at service cyberpower eu com Connect the serial USB cable to the UPS unit and an open serial port on the back of the computer You must use the cable that came with the unit The serial USB cable is not connected PowerPanel Personal Edition is inactive Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit The unit is not providing battery power For more information visit eu cyberoowersystems com or contact CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 40 2348170 E MAIL sales cyberpower eu com Entire contents copyright 2010 CyberPower Systems B V All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems USA Inc A u
Download Pdf Manuals
Related Search
Related Contents
erbrich Tycon Systems POE-INJ-1000-S direccion general de administracion direccion de recursos materiales User Manual Sunny Central Zentralwechselrichter PLIEGO DE CONDICIONES TÉCNICAS DE OXÍGENO LÍQUIDO 11_OrderREVOカタログ(4225KB) Concorrencia_001-2011 User Manual - VS-260OP TTL Flash.indd Manual de instrucciones Copyright © All rights reserved.