Home
User`s Manual
Contents
1. 008 2500 hours Battery Life 250 hours intermittent saunas sbebeyehaniesiea vale eanenets 350 hours continuous Body Material eeeeeeeees Polycarbonate Operating Temp 25 F to 115 F Ee eter cere 32 C to 46 C 5 85300M Rev1 9 7 2007 gt OBJECTIVE MOUNT IS NOT REMOVABLE TUBE 6 DIA IS 34 5mm Major Components Part Number 1 Eyepiece Lens with Rubber Shield 80000 2 ON OFF Switch Depends on serial 3 High Voltage Power Supply 61897 4 C cell battery 80148 5 Battery End Cap Assembly 85086 6 Image Converter Tube 93001 6 Image Converter Tube 93001 5 7 Quartz UV Lens Assembly 93330 Optional Objective Lens Part Number 7 One Element Quartz UV Objective 85310 7 5 Element UV Achromat Objective 93380 85300M Rev1 9 7 2007 Component Replacement The UV SCOPE is designed for ease of service The follow ing list contains specific details 1 LENSES The eyepiece and objective lenses are re tained by threads on their tubular housings a TO REMOVE THE LENSES Grasp the instrument in one hand such that the lens to be removed faces up With the other hand rotate the lens counter clockwise two or three revolutions until free b TO REPLACE THE LENSES Engage screw threads and rotate clockwise two or three revolu tions until snug Do not force or over tighten the lenses as dam age to the tube may result Care should be exer cised in engaging and disengaging len
2. 85300M Rev1 9 7 2007 Limited Warranty FJW OPTICAL SYSTEMS INC warrants the UV Scope FIND R SCOPE exclusive of batteries to be free from defects in work manship and material This obligation shall be limited to the repair and or replacement at FJW OPTICAL SYSTEMS INC option of articles or parts for which notice of defect is given in writing by the purchaser to FJW OPTICAL SYSTEMS INC within ninety 90 days from the date of shipment to the purchaser Additionally FJW OPTICAL SYSTEMS INC warrants the Infrared Image Con verter Tube and FIND R SCOPE Power Supply and optics excluding Tube breakage to be free from defects for a period of 18 months This additional obligation is limited to the repair and or replacement at the option of FJW OPTICAL SYSTEMS INC of these items The notice of defect must be given in writing by the purchaser to FIW OPTICAL SYSTEMS INC within 18 months from the date of shipment to the customer This warranty is in lieu of all other warranties and expresses the sole liability of FJW OP TICAL SYSTEMS INC with respect to the product Other FIND R SCOPE Product Lines FIND R SCOPE Infrared viewer with IR light source FIND R SCOPE 1800 amp 2200 camera viewers FIND R SCOPE Infrared video system amp monitor FIND R SCOPE Helmet amp microscope units FIND R SCOPE UV viewers FIND R SCOPE Electronic infrared viewer FIND R SCOPE Radiometric infrared viewer camera and The Speckle Bust
3. ating the rubber portion to clarify the phosphor screen grain of the image tube Caution Rotating the eyepiece beyond the point of easy movement may damage the image tube 5 Direct the viewer towards the illuminated object and look through the eyepiece lens 6 Focus the objective lens by rotating the lens to obtain the clearest and sharpest image possible 7 Repeat STEP 4 to fine focus and maximize image clarity 8 Be sure to turn viewer switch OFF when not in use 85300M Rev1 9 7 2007 UV SCOPE PARTS and ACCESSORIES LIST call for current prices Part 85300 85300 5 80380 80385 80389 80451 81850 81850 1 85206 85255 61883 61897 80000 93330 93380 85086 85282 80064 93001 93001 5 Item UV SCOPE 180 1350 nm UV SCOPE 180 1550 nm Special Filters Neck Strap Wrist Strap Close up Lens Variable Iris Volt Converter Volt Converter 16mm Lens 8mm Lens Eyeshield Power Supply Eyepiece Lens UV Objective Lens UV Objective Lens C cell Endcap Carrying Case Power Switch 180nm Tube 180nm Tube Description IR amp UV VIEWERS Hand held self contained monocular UV near infrared viewer w spectral sensitivity from 180 to 1350 nm with 26 mm f 3 0 UV grade fused silica lens and 1x magnification Hand held self contained monocular UV near infrared viewer with extended spectral sensitivity from 180 to 1550 nm with 26 mm f 3 0 UV grade fused silica lens and 1x magni
4. er FJW Optical Systems Inc 322 N Woodwork Lane Palatine Illinois 60067 4933 Tel 847 358 2500 Fax 847 358 2533 E mail irsales findrscope com Web www findrscope com 85300M Rev1 9 7 2007 LISTED FIND R SCOPE Ultraviolet Viewer User s Manual For FIW Model Numbers 85300 and 85300 5 FiJ W Optical Systems Inc 85300M Rev1 9 7 2007 Introduction Thank you for purchasing the FJW Ultraviolet Viewer Your new UV SCOPE is a wide angle monocular long wave ultraviolet viewer with a focal range from 114 3 mm 4 5 inches to infinity It is fabricated utilizing a rugged polycarbonate body with alumi num housed precision ground optics eyepiece and objective lenses It consists of several modular components which are listed on the following page Preassembled tested and ready for use the FIND R SCOPE UV Scope ultraviolet viewer should provide many years of trouble free operation Operating Procedures In order to view any object it must emit or be illuminated by some quantity of light be it visible or ultraviolet Incandescent room lights and daylight are both acceptable for checking instru ment operation Caution Viewing excessively high powered light may dam age the UV SCOPE image tube 1 Unscrew the End Cap Assembly and insert enclosed C cell battery side down into the end cap re assemble 2 Remove the lens cap 3 Turn the viewer switch ON 4 Pre focus the eyepiece lens by rot
5. fication VIEWER ACCESSORIES Special order filters available prices vary Neck strap to screw into 85300 handle Wrist strap to screw into 85300 handle Attachment for viewing within 6 of target Attachment to increase depth of field 120 Vac 60Hz Adapter to operate from wall outlet 230 Vac 50Hz Adapter to operate from wall outlet 16mm C mount camera lens 8mm C mount camera lens REPLACEMENT PARTS Rubber eyepiece eyeshield 12 000V internal power supply Eyepiece lens UVATAR 3 element Objective Lens is the standard lens supplied with models 85300 and 85300 5 UVAGON 5 element Objective Lens can be used in lieu of the standard 3 element lens C Cell End Cap assembly for current models Polypropylene case w die cut interior On Off switch 180nm to 1300 nm image converter tube 180nm to 1500 nm image converter tube 85300M Rev1 9 7 2007 NOMINAL SPECTRAL SENSITIVITY RELATIVE SENSITIVITY 0 200 400 600 800 1000 1200 1400 1600 WAVELENGTH nm Specifications Standard Sensitivity 00 180 to 1350 nm Optional Sensitivity 0 180 to 1550 nm Peak Sensitivity cceeeeeees 300 nm Field of VieW c eeeeeeeeeeeeees 40 Magnification 1 1 Focal Range 2 ccceeeeeeeeeeees 4 to infinity Dimensions 6x2 x7 in E E 15 25 x 5 4 x 17 8 cm WeiIGNL 0 ccceceeeeeeeeeeeeaeeeenees 22 oz 625g Tube Resolution 50 lines mm min Power Supply Life
6. ses in order to protect the precision thread quality necessary for proper visual alignment 2 SPRINGS The unit has coil springs located behind the eyepiece assembly and in the battery end cap 3 BATTERY The unit has one C cell battery located in the battery end cap a TO REMOVE THE BATTERY Grasp the instrument securely and rotate the battery cap counterclockwise until the cap comes off Battery is free to be re moved b TO REPLACE THE BATTERY Place the C cell battery side down into the end cap Place this end cap assembly and battery into the handle Ro tate the assembly clockwise to engage the screw threads Do NOT force or over tighten the endcap 85300M Rev1 9 7 2007 4 POWER SUPPLY A high voltage power supply is located behind above the battery end cap assembly To avoid electrical shock DO NOT REMOVE THE POWER SUPPLY unless the power switch has been turned off for at least five 5 minutes a TO REMOVE THE POWER SUPPLY Remove the battery cap and battery per instruction 3a Grasp the viewer housing such that the opening faces downward Bump the open end against the palm of the hand to dislodge the power supply TO REPLACE THE POWER SUPPLY Insert the smaller cylindrical diameter end first and press firmly into place Replace the battery and battery end cap per instruction 3b 5 IMAGE CONVERTER TUBE The image tube is located behind the eyepiece lens Caution This is a fragile glass t
7. ube Do Not Drop a b TO REMOVE THE IMAGE TUBE Remove the eyepiece lens per instruction la Tilt housing down ward keeping one hand under the opening The image tube should slide partially out If not tap the housing lightly in your palm Grasp the tube and pull it free A gentle tilting or rocking motion while pulling away may be helpful NOTE For maximum performance all external surfaces of the image tube must be free of finger prints and other dirt or high voltage arcing and im age degradation may occur Before replacing the