1. 323 324 325 Clamp Meter May 2012 Rev 1 06 15 2012 2015 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for two vears from the date of purchase This warrantv does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warrantv on Fluke s behalf To obtain service during the warrantv period contact vour nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages this limitation of liability may not apply to you Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 Table of Contents Title P
2. connected applicable to test and measuring directly to utilization points circuits connected to the distribution socket outlets and similar part of the building s low voltage points of the low voltage MAINS installation MAINS installation MEASUREMENT CATEGORY IV is applicable to test and measuring circuits connected Conforms to relevant South Korean at the source of the building s EMC Standards low voltage MAINS installation This product complies with the WEEE Directive marking requirements The affixed label indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product as unsorted municipal waste Clamp Meter How to Clean the Product Note The Measurement Categorv CAT and voltage rating of combinations of test probes test probe accessories current clamp accessories and the Product is the LOWEST rating of individual components How to Clean the Product Regulariv wipe the case with a damp cloth and weak detergent A Caution To prevent damage to the Product do not use abrasives or solvents to clean the Product case To clean the Product Jaw 1 Examine the jaw mating surface to make sure it is clean If there is unwanted material including rust jaw closure w
3. necessary for the internal function of the equipment itself Class A Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances 11 323 324 325 Users Manual Emissions that exceed the levels required bv CISPR 11 can occur when the equipment is connected to a test object Korea KCC Class A Equipment Industrial Broadcasting 8 Communication Equipment Class A Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it This equipment is intended for use in business environments and not to be used in homes USA FCC 47 CFR 15 subpart B This product is considered an exempt device per clause 15 103 Temperature Coefficients Add 0 1 x specified accuracy for each degree C above 28 C or below 18 C Resolution BOS ete earch tesa Nie RH d 0 1A 322 325 x cont anne a 0 01 0 1 A Accuracv 323 B25 ia dee 2 0 5 digits 45 65 Hz 2 5 5 digits 65 400 Hz 99A 1 5 5 digits 45 Hz to 400 Hz Note Add 2 96 for position sensitivitv 12 Clamp Meter Specifications DC Current with Jaw 325 Range ne n RA 40 00 400 0 A Resolut
4. support manuals Safety Information A Warning identifies conditions and procedures that are dangerous to the user A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test Table 1 tells you about symbols used on the Product and in this manual Clamp Meter Safetv Information AAWarning To prevent possible electrical shock fire or personal injury Use the Product only as specified or the protection supplied by the Product can be compromised Use only correct measurement category CAT voltage and amperage rated probes test leads and adapters for the measurement Do not touch voltages gt 30 V ac rms 42 V ac peak or 60 V dc Carefully read all instructions Hold the Product behind the tactile barrier See Clamp Meter item 1 Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe or accessory Do not measure current while the test leads are in the input jacks Do not use the Product around explosive gas vapor or in damp or wet environments Limit operation to the specified measurement category voltage or amperage ratings Do not work alone 323 324 325 Users Manual Do not apply more than the rated voltage between the terminals or between each terminal and earth ground Comply with local and national safety codes Use personal protective equipment approved rubber gloves face p
5. age IntrOGUCtION feet testes aa 1 How to Contact Fluke m Safety Information How to Clean the Product Specifications eret Fe EE Qa nere re Electrical Specification Sisirin ee ce Pret ri testet Mechanical Specifications Ar Environmental Specifications eese 12 The Meter eee ED eb SEP a A 14 323 324 325 Users Manual Introduction The Fluke 323 324 325 Clamp Meter the Product measures ac and dc voltage ac current resistance and continuitv The 324 and 325 can also measure capacitance and contact temperature The 325 can also measure dc current and frequency Note that the 325 is shown in all of the illustrations For temperature measurement vou must use the included K Tvpe Thermocouple AAWarning Read Safety Information before you use the Product How to Contact Fluke To contact Fluke call one of the following telephone numbers e Technical Support USA 1 800 44 FLUKE 1 800 443 5853 e Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 e Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 323 324 325 Users Manual e Japan 81 03 6714 3114 e Singapore 65 6799 5566 e Anywhere the world 1 425 446 5500 Or visit Fluke s website at www fluke com To register your product visit http register fluke com To see print or download the latest manual supplement visit http us fluke com usen
6. fully look at the insulation around the terminals Read all safety Information before you use the Product 323 324 325 Users Manual Remove batteries to prevent battery leakage and damage to the Product if itis not used for an extended period Remove batteries to prevent battery leakage and damage to the Product if is to be stored above its operating temperature Do not use a current measurement as an indication that a circuit is safe to touch A voltage measurement is necessary to know if a circuit is hazardous NCaution To avoid possible damage to the Product or to equipment under test use a thermocouple rated for the temperatures to be measured The Product is rated for 10 0 C to 400 0 C and 14 F to 752 F The included type K thermocouple is rated to 260 C Clamp Meter Svmbols Svmbols Table 1 Svmbols Direct Current AC and DC Current and DC Current Conforms to European Union EJ Batterv D Consult user documentation WARNING HAZARDOUS VOLTAGE Double insulated insulated Risk of electric shock DIDI NN by CSA Group to 5 North American safety a E to relevant Australian standards Application around and removal from Sal iy by TUV SUD Product uninsulated hazardous live conductors is permitted 323 324 325 Users Manual Table 1 Svmbols cont Meaning Measurement Category Il is applicable to test and MEASUREMENT CATEGORY III is measuring circuits
7. he Meter Exil s Jak SS MM Dj ka po CFHzVAR 323 324 325 Users Manual gtq003 eps 18 Clamp Meter The Meter 323 323 Vac 324 325 V de vac V 1 gt 30 V V gtq004 eps 19 323 324 325 Users Manual 323 700 324 325 300 gtq005 eps 20 Clamp Meter The Meter AC DC amp ZERO ZERO ZERO RO A 2 bes gtq006 eps 21 323 324 325 Users Manual gtq009 eps 22 Clamp Meter The Meter gtq007 eps 23 323 324 325 Users Manual 24
8. i r xiii iii aka iz a ertet 0 01 0 1 A ACCULACY 2 0 5 digits AC Voltage RANGE sa 600 0 V Resolution icit nri 0 1V Accuracy 45 Hz 400 1 5 5 digits DC Voltage Range iiri riri ite b erue 600 0 V Resolution 0 1 V ACCULACY E in i 1 5 digits Resistance Range 2 400 0 4000 400 0 4000 40000 Resol tioni a chic an 0 1 1 10 Q ACCUIAGCY 1 1 1 5 digits 13 323 324 325 Users Manual Continuitv Beeper lt 70 Q 324 920 a tenes 30 Q Capacitance 324 325 RANGE en 100 0 1000 uF Resolution nir rft 0 1 1 uF PACCUNACY TERES 1 4 digits Frequency with Jaw 325 Range ii 5 0 to 500 0 Hz Resolution i 0 1 Hz ACCUNACY nat ni C dee ea da 0 5 4 digits Trigger Level etn 5to 10 Hz 210A 10 to 100 Hz 255 100 to 500 Hz 210A Contact Temperature 324 325 Rang Eninde tet e p cendi 10 0 C to 400 0 C Resolution nn 0 1 C ACCURACY 1 8 digits Note Temperature uncertainty accuracy does not include error of the thermocouple probe 14 Clamp Meter The Meter The Meter Clamp Meter E H E gtq008 eps 15 323 324 325 Users Manual 323 i N gtq001 eps 64 Cla T
9. ill not be correct and there will be measurement errors 2 Open the jaws and clean the clamp metal ends with a lightly oiled cloth 323 324 325 Users Manual Specifications Maximum voltage between any Terminal and Earth Ground 600 V Range D 400 0 A 324 325 dst icai irit dei 40 00 400 0 A Batteries ir ai ie 2 AAA NEDA 24A IEC LRO3 Operating Temperature 10 C to 50 C Storage Temperature 30 C to 60 C Operating Humidity Non Condensing lt 10 C lt 90 RH at 10 C to 30 C lt 75 RH at 30 C to 40 C lt 45 RH at 40 C to 50 C Without Condensation Operating Altitude 2000 meters Storage Altitude 12 000 meters Size Ix W x E iuret 207 x 75 x 34 mm 10 Clamp Meter Specifications Weight RD 265g BOA C eteates 208 g B25 IP 283 g Safe ii a es IEC 61010 1 Pollution Degree 2 IEC 61010 2 032 CATIV 300V 600V IEC 61010 2 033 CAT IV 300V CAT 600V IP Rating L IEC 60529 IP30 non operating Electromagnetic Compatibility EMC International IEC 61326 1 Portable Electromagnetic Environment IEC 61326 2 2 CISPR 11 Group 1 Class A Group 1 Equipment has intentionally generated and or uses conductively coupled radio frequency energy that is
10. rotection and flame resistant clothes to prevent shock and arc blast injury where hazardous live conductors are exposed Replace the batteries when the low battery indicator shows to prevent incorrect measurements The battery door must be closed and locked before you operate the Product Measure a known voltage first to make sure that the Product operates correctly Remove all probes test leads and accessories that are not necessary for the measurement e Only use probes test leads and accessories that have the same measurement category and voltage rating as the Product Keep fingers behind the finger guards on the probes Clamp Meter Safetv Information Connect the common test lead before the live test lead and remove the live test lead before the common test lead Remove all probes test leads and accessories before the batterv door is opened Do not use the Product if it is damaged Disable the Product if it is damaged Do not use the Product if it operates incorrectly Do not use test leads if they are damaged Examine the test leads for damaged insulation exposed metal Check test lead continuity Before each use examine the Product Look for cracks or missing pieces of the clamp housing Also look for loose or weakened components Carefully examine the insulation around the jaws See Clamp Meter item 2 Examine the case before you use the Product Look for cracks or missing plastic Care