1. 5 Features 1 No call charges the GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action on the first ring 2 Multiple applications gates bollards barriers garage doors shutters and access doors or machines Secure Using caller ID for identification unknown callers are ignored Can be operated from anywhere no distance limit Add or remove users by SMS Text command No need to provide a remote control for different users Up to 64 authorized phone numbers can be configured Two Digital inputs for door sensor motion sensors or other sensors to protect your door and windows when any one of them triggered will send SMS alert message and start the siren immediately 9 One output with relay rating 3A 240VAC for connecting the switch of the door or machines 10 The relay action will return a SMS confirmation to the owner this function is editable by user 11 Based on GSM Network applied to many applications 2 2 oe 2S 6 Settings 1 The default Password is 1234 2 All the settings are through SMS commands please edit the below SMS commands in your cell phone then send to the RTU5015 Unit The unit cannot support PIN Code Protected SIMCard 3 You can program the GSM Gate Opener with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted Page 5 of 14 King Pigeon Hi Tech Co
2. Ltd Page5of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer a Fa i GSM Transformer Alarm System amp GSM House Alarm System amp GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance 4 The relay output will change the close or open status by every call in please note it Means the first time call it it will close the relay to switch on the lock if the second call in is in the setting time then the unit will ignore the setting time and open the relay to switch off the lock or machine 5 The functions of the two inputs are the same The two digital inputs will be in armed mode after 10minutes from the last call in 6 Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character 7 The pwd inthe commands is means the password when you use it please in stand of it by the digital number the capital letters PWD is the command letter use PWD directly 8 If you use this model for gate open you only need to change the password and setup the authorized numbers 9 In some GSM operators they use different SMS parameter the units can t return the SMS confirmation is normally It is not product problem Also you can try to add the country code b
3. Relays When call in the unit the Relay 1 will switch on and keep a preset time O 9 5Seconds the command is the same as 6 10 then switch off after past an interval preset time O 99Seconds the relay 2 will switch on automatically and keep a preset time O0 9 5Seconds this time will be the same as Relay 1 then switch off The relay switch on relay time cannot be setup as 0 SMS Command and Explanation Setup Interval Time jppwd ADLxx xx 01 99 stands for 1 99 seconds The End Any questions please help to contact us feel free Email Us Sales Kingpigeon com cn Hitp www GSMalarmsystem com Hitp www Kingpigeon com cn Page 14 of 14 King Pigeon Hi Tech Co Ltd Page14o0f14 Ver 1 4 File No RTU501513
4. a gas station Power off GSM Gate Opener when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regulations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Page 3 of 14 King Pigeon Hi Tech Co Ltd Page3of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer a GSM Transformer Alarm System amp GSM House Alarm System amp GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn 3 Standard Packing List Control Unit X1 GSM ANT X1 User Manual X1 CD Connector X1 AC DC Adaptor X1 Android Apps in CD Optional Accessories Wired Sensors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Temperature Sensor Infrared Beam Fence Vibration sensor Siren 4 Physical Layout 4 1 Control Unit physical layout Relay GSM Power GSM Gate Opener GSM Remote Controller RTU5S015 12VDC Interface Instruction Relay Status calling in the relay will work this LED Indicator will on When the wired sensor triggered the LED indicator will on Otherwise is off When insert the SIMcard into the Slot and power on will flas
5. message not input 2 message 7 Installation Page 9 of 14 King Pigeon Hi Tech Co Ltd Page9of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer a GSM Transformer Alarm System amp GSM House Alarm System amp a GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Before installing the control unit and sensors and sirens please help to test the system firstly including wired sensor power supply gsm signal etc 7 1 Insert SIMcard into Control Unit In the backside of the control unit please install the GSM SIM card 7 2 Connecting the Wired Sensors Please help to see below wiring diagram then fixed the related wired sensors the sensors connect to the related digital inputs and the siren should connect to the Siren and Com connection port 7 3 Connecting the Electronic Lock or Electricity equipments 01 O1 sirensNA412V Int In2 Page 10 of 14 King Pigeon Hi Tech Co Ltd Page 10o0f14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer lt F GSM Transformer Alarm System amp GSM House Alarm System amp al GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn O1 O4 Siren NA 12V Ini In 220VAC 220VAC ge H E SERSE 7 4 Install the Mainframe The mainframe should be installed in the
6. position that person can not get it and there re with a power source as well as enough GSM signal coverage 8 Technical specifications Rated Voltage 12VDC 1A Working temperature 100 O 600 Storage temperature 20 O 60 Relative humidity 10 90 No condensation Work frequency 900 1800MHz Communication protocol GSM PHASE 2 2 include data service Wired Zones 2 Related Voltage of the Output Relay 3A 240V AC Net Weight 0 50Kg 9 Important information _ hk Please read the User Manual carefully before you install the Control Unit and set the Control Unit 2 Install the system in a hidden place 3 Avoid getting water into the Control Unit 4 Have a secure connection to the main power supply 10 Maintenance Page 11 of 14 King Pigeon Hi Tech Co Ltd Page 110of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer a oe Pe GSM Transformer Alarm System amp GSM House Alarm System amp al GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn 1 Incase of failure please contact the distributor or manufacturer 2 Ifthe remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 Ifthe Control Unit can ru
7. Digital Input 1 Digital input 2 activated or recovered will send SMS Alarm Message to Authorized Users immediately The SMS Alarm Message can be programmed by users SMS Command and Explanation IN1 Activated SMS pwd TEXT2Oxxxxxx IN1 Recovered SMS pwd TEXT2Cxxxxxxd IN2 Activated SMS pwd TEXT1Oxxxxxx IN2 Recovered SMS pwd TEXT1Cxxxxxxd Can Enable or Disable to send SMS to the No 1 2 Authorized User while any phone number accessing the unit Default 1s Disable SMS Command and Explanation Enable SMS Command Will return Enable Feedback accessing number to No 1 2 by SMS Disable SMS Command Will return Disable Feedback accessing number to No 1 2 by SMS 999 Users when alarm occurrence the siren will not make sound The siren should be switched on off by SMS Commands SMS Command and Explanation Setup Authorized number pwd TELAuthorized Number Serial Number The serial number should be 3 digits e g the first number must be 001 not 01 Switch On Siren pwd RLC Switch Off Siren pwd RLR Page 13 of 14 King Pigeon Hi Tech Co Ltd Page 1i3o0f14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer _ anw GSM Transformer Alarm System amp GSM House Alarm System amp ai GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Special for ONE Button On another Button OFF applications 2 Digital Output
8. GSM Gate Opener Use your Mobilephone to Open the Gate Door KING PIGEON Ife Call it to Open the KING PIGEON A Professional GSM Alarm System designer and manufacturer GSM Transformer Alarm System amp GSM House Alarm System amp ii GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Table of contents 1 Brief introduction 3 2 Safety Directions 3 3 Standard Packing list 4 4 Physical Layout 4 5 Features 5 6 Settings 5 7 Installation 9 8 Technical specifications 11 9 Important information 11 10 Mamenance e 11 11 Quality Warranty 12 12 Model Comparison Table and Special SMS Commands 12 This handbook has been designed as a guide t
9. U501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer a oe Pe GSM Transformer Alarm System amp GSM House Alarm System amp ai GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn The Authorized Numbers call in will not switch on the relay the others number call in will switch on the relay The relay close time from 5 seconds to 60 minutes Default is 30 minutes SMS Command same as 6 10 but the time value 0 19 stands for different time see below 01 5s 02 30s 03 60s 04 120s 05 240s 06 360s 07 480s 08 600s 09 720s 10 900s 11 1200s 12 1500s 13 1800s 14 2100s 15 2400s 16 2700s 17 3000s 18 3300s 19 3600s E g for RTU5015 1234 GOT10 stands for the relay close 5 seconds but for RTU5015 D this command means the relay close time is 900 seconds While the relay at switch on status call in the unit the relay will switch off immediately When setup the relay close time less than 60 Seconds will not send SMS to users when setup the relay close time more than 60 seconds will send SMS to alert at both switch on SMS Content is The relay is ON or switch off SMS Content is The relay is OFF this function can be disabled by SMS commands the commands are the same as 6 13 chapter SMS Command and Explanation The same as RTU5015 but the relay close time stands for different value See abovementioned point 2 descriptions Once
10. correct the RTU5015 will return Command error please re send So please check the Command or add the country code before the telephone Page 6 of 14 King Pigeon Hi Tech Co Ltd Page6of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer en j GSM Transformer Alarm System amp GSM House Alarm System amp al GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn lt number or check the input is in ENGLISH INPUT METHOD and CAPS LOCK 13 The SMS commands that you will certainly use in the GSM Gate Opener are the following 6 1 Setup New Password if successful the unit will return Password modified OK For example the original password is 1234 you want change it to 6666 then you can send the command below 12344 PWD6666 PWD6666 6 2 Setup Authorized number E g if you want to setup 13570810254 as the first user number and the password is 1234 then you can send to the RTU5015 unit Tips 1 the authorized number means the one who can dial the RTU5015 unit to open it 2 We strongly recommend that the serial number of 01 and 02 are cellphone number because of the alarm message only send to the first and second position numbers 3 The Serial Number is the position to store the authorized number from 01 64 6 3 Inquiry the Serial Number s Authorized number E g If you want to know the authorized number at po
11. e the digital inputs Alarm Inputs Enabled means Enable digital inputs 6 8 Setup allow all calling in numbers can access it Tips This command allows anybody calling the SIM number to access it Warning With the above command you allow free access to anybody calling 6 9 Setup only authorized number can access it Default Tips With the above command you allow only people that are in the authorized number list can access the RIU5015 This is the standard and recommended option Inquiry this setting Reply Allow all numbers can access it or Allow User Number can access it only 6 10 Setup the relay close time Tips The time should be in 0 9 5seconds This command is useful in case you need to keep the relay closed or button pressed longer The default time is 0 5seconds 500 ms You can change it with the GOT command The relay closed time is twice as the number you set e g if you set pwd GOT19 means the relay closed 19 2 9 5Seconds To check the value you can use the command the unit will reply the current value If you want to let the relay always closed until you call it next time then you can set the time as 00 the format is lpwd GOTOO the relay will be always closed until next time call in in this case only the 1 2 3rd authorized number can access it The other authorized numbers can not access the unit This is very useful for remote switch on or switch off the electricity appliance or equipment or d
12. efore the number see the below settings For example In China the country code is 0086 or 86 The user cell phone number is 13570810254 and has been assigned as a SMS Alert number the simcard number in the panel is 13512345678 Problem 1 Alarm but the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means setup 008613570810254 to instead of the 13570810254 Problem 2 The user number can receive the SMS Alert message from alarm panel but the alarm panel can not receive the commands from the user number Solution Please add country code to the simcard number in the alarm panel Means send sms commands to 008613512345678 to instead of 13512345678 Solution 3 When you use cell phone dial another one what number it will be displayed then you can set the displayed number as dial numbers when you use cell phone send SMS to another cell phone what number it will be displayed then you can set the displayed number as SMS Alert number just use the 00 to replace the also you can try the 10 Please write down the Authorized number list in a paper for review in further 11 If you want to reset the RTU5015 to factory default then please send to it within 3 minutes after switch on the RTU5015 The GSM Led in RED status if the GSM LED change to GREEN then the RTU5015 can not respond this command 12 If the command is in
13. er and manufacturer GSM Transformer Alarm System amp GSM House Alarm System amp ai GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn 1 Brief introduction The GSM Gate Opener RTU5015 is a very simple device which can be used for authorized door access controlling gates switching of remote equipments car parking systems Actually the GSM Gate Opener RTU5015 can be used in places which require turning ON OFF your system machines equipments remotely with a FREE call from your mobile phone and protect your assets Just dial from Authorized User number then the Barrier and doors are opened or the machine are turn on or off by the GSM Gate Opener There are no call costs the GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action Moreover the RTU5015 with 2 digital inputs for digital inputs when any one of the inputs triggered will start the siren or switch on the light in the meanwhile the RTU5015 will send SMS Alert the to owners immediately This is very useful if you need protect your assets with low cost solution 2 Safety Directions Safe Startup Do not use GSM Gate Opener when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM Gate Opener and influence its performance Avoid Use at Gas Station Do not use GSM Gate Opener at
14. evice for a long time 6 11 Modify the digital input type Modify the digital input type as NC if the sensor you used with this unit is NC then you should set the unit as NC type Tips when you set the digital inputs as NC if you don t use the input please connect the digital inputs by a wire to short it Otherwise it will alarm E g if you only use the input 2 then you should use a wire to Page 8 of 14 King Pigeon Hi Tech Co Ltd Page 8of14 Ver 1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer lt E GSM Transformer Alarm System amp GSM House Alarm System amp al GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn connect the input and GND point to make it as Normal Close Modify the digital input type as NO if the sensor you used with this unit is NO then you should set the unit as NO type The default is NO 6 12 Check GSM signal quality Check GSM signal quality This command is useful to see the GSM network signal level of your GSM Gate Opener is receiving After you send the command you can receive a SMS with signal quality in range 0 to 32 if it is O we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external GSM antenna if this is not the case or eventually even change operator with another that ser
15. h 10S with red color then the Led will change to Red color not flash for 3minutes In this 3 minutes you can send RESET to reset the RTU5015 When registered GSM Network successful will change to Green color not flash When calling in the relay works will change to Red color External 12VDC Power LED indicator Output 1 the relay rating is 3A 240VAC connect to the switch of the lock or devices Page 4 of 14 King Pigeon Hi Tech Co Ltd Page4of14 Ver1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer i GSM Transformer Alarm System amp GSM House Alarm System amp w GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Ee Output 1 the relay rating is 3A 240VAC connect to the switch of the lock or devices Siren connector connect to the Siren Positive lf need the siren start when the sensor triggered must connect this connector with 12VDC connector If not use the siren then needn t connect it awe Connect to the NA Point when sensor triggered will start the siren for 90Seconds 12VDC Also it can be connected to wired sensor to supply 12VDC power for sensors if need Common connect to Siren Negative another wire of the two wired sensors Digital input 1 connect to one wire of the first wired sensor Digital input 2 connect to one wire of the second wired sensor 12VDC The external power input 12VDC 1A
16. n and sensors work but cannot send SMS texts please change SIM Card to check it 4 Ifthe problem cannot be solved please contact the distributor or manufacturer 11 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers 12 Model Comparison Table and Special SMS Commands Function Different Description for Different Models Standard Version 64Users 900 1800 Mhz 1 Relay Output for switching on off gate or device by authorized users call in the relay close time can be setup by SMS The siren will make sounds once any digital input activated The digital inputs are effective only after 10 minutes of the latest call in SMS Command and Explanation See the Chapter 6 GSM Frequency 850 1900 Mhz SMS Command and Explanation The Same as RTUSO15 Included internal Backup Rechargeable Battery 12V 300mAH standby time is 6 hours SMS Command and Explanation The Same as RTU5015 When alarm occurrence the siren will not make sound The siren should be switched on off by SMS Commands SMS Command and Explanation Switch On Siren pwd RLC Switch Off Siren jpwd RLR Page 12 of 14 King Pigeon Hi Tech Co Ltd Page12o0f14 Ver1 4 File No RT
17. o the installation and operation of RTU5015 GSM Gate Opener Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be sought before any Installation work commences King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook Upgrade Version Ver1 4 Date 2012 10 28 Plus other versions information at chapter 12 And includes the Android Apps in CD of the standard package Upgrade Version Ver1 3 Date 2010 08 18 1 Added Reset Function 2 Added Authorized Number setup example 3 Modified the GSM LED status for the 1 3 Version 4 Corrected some Return SMS Texts there re Door Open Return SMS Door Open Not Return SMS Relay action return SMS ON Relay action return SMS OFF If you want to setup RTU5015 A B C D E F 1 1l please read the Chapter 12 at page 12 firstly otherwise can not be setup successfully Page 2 of 14 King Pigeon Hi Tech Co Ltd Page2of14 Ver1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System design
18. sition 2 and the password is 1234 then you can send 1234 TELO2 to check it 6 4 Remove the Authorized Number or you can overwrite with another number you wish to change it E g if you want to remove the authorized number at position 12 and the password is 1234 then you can send 1234 TEL 1 2 6 5 Disable the digital inputs Default is disable Tips if you want to use the digital inputs please enable it firstly 6 6 Enable the digital inputs Tips if you enable the digital inputs function the sensors will enter Armed status after 10minutes of the latest dial in in the first 10minutes when the sensor triggered will not alarm after 10minutes the unit in armed mode when any sensor triggered will start the siren if you connected or switch on the light if you connect it and send SMS to the Position 01 and 02 authorized numbers immediately This function is very useful for garage or other applications It can protect the assets for you by GSM Network Page 7 of 14 King Pigeon Hi Tech Co Ltd Page 7of14 Ver1 4 File No RTU501513 KING PIGEON A Professional GSM Alarm System designer and manufacturer lt GSM Transformer Alarm System amp GSM House Alarm System amp al GSM Telemetry Units amp GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn 6 7 Inquiry Alarm Setting Reply Alarm Inputs Disabled jor Alarm Inputs Enabled Tips Alarm Inputs Disabled means disabl
19. ves your area better 6 13 Enable return SMS confirmation when Relay action Tips if you enable it when the relay action close or open the unit will return a SMS confirmation to you The return SMS is The relay is ON or The Relay is OFF You can disable it by the following command pwd N Default is no return SMS confirmation when relay action This is very useful when you use the RTU5015 to control the equipments remotely To check the settings you can use the command it will return Relay action return SMS ON or Relay action return SMS OFF 6 14 Modify the Alarm SMS message when inputs triggered The user can modify the digital inputs alarm SMS message by the following command the SMS Alert message should less than 30 letters When the sensor triggered these SMS message will send to the Position 1 and Position 2 cell phone numbers to alert the user The default SMS Alert message is Door Open Alarm The above command is use to modify the digital input 2 alarm SMS text message The above command is use to modify the digital input 1 alarm SMS text message E g Modify the digital input1 alarm SMS Text message as Left Windows Open If the password is 1234 then you can send Tips 1 This command includes two 2 The xxxxxxxx in this command Is indicates the message contents 3 The TEXT1 is part of the command refer to the input 2 message not input 1 message 4 The TEXT2 is part of the command refer to the input

Download Pdf Manuals

image

Related Search

Related Contents

Crate Amplifiers VC-120H User's Manual  Samsung PL80 Kullanıcı Klavuzu  Zenoah EB7000 User's Manual  設置編  Delta Electronics LCP-4250A4CDR User's Manual  ClosetMaid 8983 Instructions / Assembly  ICY BOX IB-319STUS2-B storage enclosure  Samsung SWE-1400 Manuel de l'utilisateur    manual de usuario dispensacion  