Home
"user manual"
Contents
1. Mounting AA internal View PC Resin Cover ABS Side Upper Cap i Q Y gt Terminal Block Optional Power LED Indicator VR1 For tx power adjustment EVRI Beam alignment LED Indicator Red SWi PowerLED Indicator Response Time Slide Switch Green is fy a LOOCO GT 007 Buzzer JP1 Buzzer alarm for beam alignment Remove JP1 cancel the function after beam aligned properly JP2 Jumper closed 1beam broken alarm 2sec function existed JP2 Jumper opened 1beam broken alarm 2sec function removed Sensing range V S Sunlight Mounting Bracket Sunlight Lux Sensing Range lt 30 000 8meters lt 40 000 7meters lt 50 000 6meters lt 60 000 ometers lt 70 000 4meters 3meters P4 BS 200RC BS 400RC BS 600RC BS 800RC e BS 200RC 2 Beams 57 cmlong BS 400RC 4 Beams 105 cmlong M2 mi 4or 6 or8 beams BS 600RC 6 Beams 153 cmlong WI B or W BS 800RC 8 Beams 201 cmlong B Black finishhousing e W White finish housing Applications O Indoor Outdoor perimeter security system D Window Door When the mounting space is limited Internal
2. Length VR1 On Tx Side Cap TP TP GND V O O O O O O O Oj Typical Installations 2 ERS CO OCET Ie LN n Windows Internal External Item Length cm BS 200RC 57 BS 400RC 105 BS 600RC 153 BS 800RC 201 Rx __ Response Time Slide Switch SW1 P SW1 SW1 SW1 j ON 2 C Left side cap i EE EEO JP2 Jumper gt When Jumper closed Onebeam broken alarm 2sec function existed ae swt E ELO e Fa m 50ms 100ms 150ms 200ms OKS oooooo0oo0o0o0o00 rz Ri ght side cap 7 When Jumper opened Onebeam broken alarm 2sec function removed JP1 Jumper When Jumper closed Buzzeralarm for beam alignmentfunction existed When Jumper opened Buzzeralarm for beam alignmentfunction removed gt A TamperSwitch B TamperSwitch Left side cap noo C VR1 Potentiometer for Tx power adjustment D TamperSwitch eg TP
3. TP GND V E TamperSwitch 0000000000 Right side cap
4. A 75mA 45mA Tx Rx Tx Rx Tx Rx Tx Rx 45mA 45mA 55mA 48mA 65mA 52mA 75mA 55mA Beam Aligned Beam Broken Applications Installation Notes RX Correct nah fi ZOON CO PEO TES Windows In Correct Terraces Sliding Door l Correct Suggestion of installation gt pi If the wires needs to be coming from the top sides please seal the opening with silicon glue to prevent the water from leaking in Correc But the best installation willbe that the wires running out on the end Blocks Blocks q Terminal Terminal External Sunlight Protections D _ Internal X TX Protections iw TX R X Response Time i x x x Broken one beam Response time 2 sec Broken two adjacent beam Response time 0 5 sec Response Time Adjustment SW1 Rx SW1 SW1 SW1 SW1 a P x 1 2 1 2 1 2 1 2 50ms 100ms 150ms 200ms Dimensions Top View Length Side View
5. External protection Terrace Sliding door Features I Aluminum housing PC Resinanti UV cover ABS Terminalblock connection side cap Alarm Breakone or twoadjacent beams Tx power adjustment By VR1 ON Tx sside cap Sensing range 8 meters 26 ft outdoor 16 meters 52 ft indoor Max N O N C Common relay output Mounting hardware included Anti tamper circuittriggers alarm ifpower is cutor end cap isremoved Slim aluminum housing anti high low temperature fog rains 2o0r4 6 8 separate photoelectricbeam sensors Programmable trigger onsimultaneous breaking of No synchronizing wiresrequired any single 2 adjacent beamsor 2 adjacentbeams Led alignment indicator broken only selected by JP20n Rx s side cap Tamperswitch Specifications CE 8 meters 26 feet max outdoor 16 meters 52 feet max indoor 10 24VDC Break one beam or two adjacent beams 1 1 beam 2 seconds alarm 2 2 adjacent beams immediately 4 beam broken alarm trigger function can be removed See JP2 which located at Rx s side cap JP2 Jumper closed 1 beam broken alarm 2 sec function existed JP2 Jumper opened 1 beam broken alarm 2 sec function removed Sensing range Input Voltage Detection method Signal output Normal open Normal close Common relay output 50 100 150 200 ms selectable by SW1 slide switch Rx 1A 120VAC 1A 24VDC a when turn cloc
6. kwise become stronger b when turn counter clockwise become normal Response Time Rx Contact rating Tx Power Adjustment by VR1 Wiring Connection Terminal block See page 4 Green Led On both Tx Rx unit Red Led On Rx unit On when beam is broken Off when beam is aligned properly Power Led indicator On powered Off no power Led indicator for Beam alignment a On when sensor is connected with DC power amp before beam alignment is done b Off when beam aligned properly automatically This function can be cancelled by JP1 removed Buzzer Alarm for beam alignment Black jumper1 JP1 ON Rx unit Tamper Switch 4 pcs each set 2 on both sides of Tx 2 on both side of Rx 45 C 55 C 49 F 131 F Dimensions W 35 mm H 30 mm L see following Humidity 70 P1 Operating Temp gt One beam broken continued 2 senconds alarm triggered Cancelled JP2 jumper opened Conditions BS 200RC BS 400RC BS 600RC BS 800RC Tx Rx Tx Rx Tx Rx Tx Rx 45mA 32mA 55mA 35mA 65mA 38mA 75mA 42mA Tx Rx Tx Rx Tx Rx Tx Rx 45mA 40mA 55mA 43mA 65mA 45mA 75mA 48mA Beam Aligned Beam Broken gt One beam broken continued 2 senconds alarm triggered Existed JP2 jumper closed Conditions BS 200RC BS 400RC BS 600RC BS 800RC Tx Rx Tx Rx Tx Rx Tx Rx 45mA 38mA 55mA 40mA 65mA 43m