nubitek_sms-manager_manual_v1.3_en
Contents
1. Calling Nubitek at 34 91 448 24 39 and asking for a Nubitek Key for your system www nubitek com 14 29 nu bi te K User Manual sms manager 7 Program functions introduction and example Nubitek SMS Manager consists of 3 functions that are simple to use and easily integrated into any control program Description SMS Manager performs all the general management procedures of the application as well as port control and modem initialisation It must be called once during all program cycles at the start Send SMS is used once for each of the SMS messages that need to be sent It is called with the activation or sending condition and it requires the text and the destination mobile numbers There is no limit to the number of different SMS messages that can be sent Receive SMS is used to define the keywords that the control program must recognise within the incoming SMS messages The function analyses the received SMS messages and activates an output bit when they are found There is no limit to the number of different messages that can be recognised A simple example In this simple example the 3 functions are called from the main program block Network 1 SMO 0 SMS_Manager Ready 00 0 Network 2 Alarm Stop Bloque de Datos SMS Stop Alarma maquina parada por averia Tel David 34666000000 Network 3 SMD Receive SMS Active TXT_1 Process 4TXT 2 SMS Rcv F Start Pro
2. www nubitek com 9 29 nu bi te K User Manual sms Manager 5 Hardware connections and configuration Required Equipment The following hardware elements are required for installation A SIMATIC S7 200 CPU CPU224 v2 0 or higuer A GSM modem with antenna and power supply There are two options available Siemens TC35i Dual Band EGSM900 GSM1800 MHz Siemens TC65 Quad band GSM 850 900 1800 1900 MHz A SIM card from any mobile telephone operator APC PPI Multimaster cable ref 6ES7 901 3CB30 OXAO of Siemens AO pin male male Sub D adapter 9 pin Sub D Adapter PC PPI Figure 5 1 Equipment required for SMS communication Configuration of the PC PPI cable The Multimaestro cable has 8 micro switches on the side of the casing that enables its mode of operation to be configured In order for Nubitek SMS Manager to be able to communicate correctly with the GSM modem the PC PPI cable must be configured in 9600 bauds mode 10 bits PPI Freeport and remote connection 010001 10 Mimoswth 1 2 3 4 5 6 7 8 Position 0 1 0 0 0 1 1 0 If a previous generation of PC PPI cable is to be used with only 6 micro switches the configuration is 000110 Nubitek does not guarantee the operation of all the Nubitek SMS Manager characteristics if this type of cable is used particularly the Teleservice functions NOTE Each time the configuration of the micro switches is changed th
3. second www nubitek com 12 29 nubitek User Manual sms manager 6 Test mode and Nubitek key The Nubitek SMS Manager library can be downloaded and distributed for free and can be freely installed into STEP7 MicroWIN requires a key to run successfully in S7 200 can berun in test mode in order to try it out for free Nubitek Key This key will enable Nubitek SMS Manager to function during an unlimited period of time Without a correct password the program shuts down the modem and freezes The key must be entered in the PLC program itself as parameter Nubitek KEY ofthe SMS Manager function Network 1 SM SMS Manager Ready F 00 0 Figure 6 1 Nubitek key in the control program IMPORTANT the Nubitek key is associated to the GSM modem used during installation in other words In order to obtain a key the IMEI of the GSM modem that is going to be used must be declared The key enables Nubitek SMS Manager to function solely and exclusively with that modem and no other What is the IMEI The IMEI is a unique identification code that each GSM hardware device has modems mobiles etc It is a 15 digit number that indicates the manufacturer country and serial number it is unique in each modem On Siemens modems the IMEI is indicated on the label on the back beneath the bar code Figure 6 2 Back of the TC35i modem and location of the IMEI www nubitek com 13 29 nubitek sms man
4. Block Send condition The Send SMS function must be called when the SMS send condition is fulfilled Important Send SMS need be executed only once in other words one single program cycle In order to avoid the SMS message being sent repeatedly it is advised to indicate the activation condition followed by a rising edge Note the Send SMS function ignored the send instructions when the Ready bit is not active Network 2 Low Level Dil Send SMS tB S000 tw E3100 Figure 9 3 The call to Send_SMS must be made using an edge www nubitek com 18 29 nu bi te K User Manual sms manager Anti bounce filter A situation can arise in which due to the bounce effect of the activation condition the same SMS message is sent several times This will happen if the activation condition is not fully reliable for example because of a bad contact a lack of hysteresis in the analogue signal threshold etc If you wish to include an anti bounce filter you must use a disconnection timer before the rising edge For example for a protection of 10 minutes do the following Network 3 Low Level Dil Network 4 Send SMS Figure 9 4 Effective anti bounce filter in order not to receive several SMS message from the same warning How to insert a value into the text of the SMS message Nubitek SMS Manager is able to insert a variable at any desired position of an SMS message This can be done easily and automatically It is
5. fulfils any of the defined parameters It is even possible to capture numeric values contained in SMS messages and store them in memory Teleservice Nubitek SMS Manager is compatible with Teleservice access which can be activated locally or remotely by means of a SMS message www nubitek com 5 29 nubitek sms Manager User Manual 2 Quick start and application examples The quick start manual is available for download from the Nubitek website providing rapid contact with the library from a mainly practical perspective The same page of the website also contains example projects that demonstrate and discuss in detail exactly how Nubitek SMS Manager can be applied Tutorial example with all the basic SMS sending and receiving options discussed and explained from an educational perspective Examples of how to program the practical situations that are shown in the graphic animations on the Nubitek website If you would like to receive a programming example that addresses a specific requirement do not hesitate to contact the Nubitek Support experts via the online support form or by calling to 34 91 448 24 39 www nubitek com 6 29 nu bi te K User Manual sms manager 3 Minimum requirements CPU S7 200 Nubitek SMS Manager requires a latest generation in other words with reference xxx23 firmware 2 0 CPU 224 or above The following is a list of valid CPUs CPU 224 DC 6ES7 214 1AD23 OXBO CPU 224 AC 6
6. ES7 214 1BD23 OXBO CPU 224XP DC 6ES7 214 2AD23 0XB0 CPU 224XP AC 6ES7 214 2BD23 OXBO CPU 226 DC 6ES7 216 2AD23 OXBO CPU 226 AC 6ES7 216 2BD23 OXBO PC PPI Cable The PC PPI cable that has been taken into consideration for the development of this application is the Multimaestro PC PPI cable with reference Siemens 6ES7 901 3CB30 0XAQ Therefore this is the cable that Nubitek recommends for connecting the CPU port to the GSM modem Previous versions of the cable or other PC PPI adaptor models may be valid however Nubitek can not guarantee correct communication functions STEP7 MicroWIN In order to install and use Nubitek SMS Manager STEP7 MicroWIN 4 0 Service Pack 2 or a later version is required Program memory The Nubitek SMS Manager library requires 6 0 Kbytes of the S7 200 program memory Variables memory The Nubitek SMS Manager library reserves a total of 771 bytes of V memory in order to be able to perform the internal management of its operation variables Users should not use this area in their control program www nubitek com 7 29 nu bi te K User Manual sms Manager 4 Installing Nubitek SMS Manager Nubitek SMS Manager is a library that manages the sending and receiving of SMS messages and is ready for integration into the STEP7 MicroWIN programming environment What is a Library A library is a sub program that performs a specific control function in an independent and encapsulated manner For that r
7. K User Manual sms manager m Value amp VD2500 If the temperature is such that VD2500 equals 113 6324 when the SMS message is sent the text received will be The temperature of the oven is 113 632 degrees Hetwnrk 6 Send 5M5 JS SHS Texts VB1DDO The temperature of the oven is amp R degrees Telephone numbers VBl10D0 34600123456 Figure 9 6 Insertion of variables into an SMS message The benefits of using symbols The use of symbols to name program variables is always beneficial in any application For an SMS management program it can spectacularly improve the legibility and maintenance of the program Every message every telephone number every activation condition and every variable to be inserted can have its own symbolic name Compare the example in Figure 9 6 with the example in Figure 9 7 Of the two ways to send a maintenance alarm when an alarm is activated due to excess oven temperature the second is obviously the clearer of the two Hetwork 6 T ven HIGH Send 5H5 SMS ALAHM 45M5 amp T el Maintenances Tal 1 amp I Ovens value SMS Texts SHS ALARM The temperature of the oven is amp R degrees ZZ Telephone numbers Tel Maintenance 34600123456 Figure 9 7 Insertion of variables in an SMS message using symbolic notation www nubitek com 20 29 nu bi te K User Manual sms manager How to apply symbolic notation It is advised to name the message an
8. LE 15 8 SMS MANAGER THE MAIN FUNCTION 16 SMS MANAGER PARAMETERS 16 9 SENDING SMS MESSAGES 17 SEND SMS PARAMETERS 17 DEFINITION OF THE TEXTS AND DESTINATION TELEPHONE NUMBERS 17 SEND CONDITION 18 HOW TO INSERT A VALUE INTO THE TEXT OF THE SMS MESSAGE 19 THE BENEFITS OF USING SYMBOLS 20 10 RECEIVING SMS MESSAGES 22 RECEIVE SMS PARAMETERS 22 FLEXIBLE RECOGNITION 22 OTHER CHARACTERISTICS 23 VALUE CAPTURE EXAMPLE 23 11 USER VARIABLES AREA 24 MAP OF THE USER VARIABLES AREA 24 ERROR EVENT CODES 26 12 TELESERVICE AND MANAGEMENT OF PORT O 27 How TO ACCESS THE CPU FROM STEP7 MICROWIN 27 REMOTE ACCESS USING TELESERVICE 27 LOCAL ACCESS VIA PORT 28 13 INTERNET SERVICE AND SUPPORT 29 NUBITEK SUPPORT 29 FAQ 29 www nubitek com 4 29 nu bi te K User Manual sms manager 1 What is Nubitek SMS Manager Description Nubitek SMS Manager is a piece of control software that enables a Siemens PLC S7 200 device to be combined with a GSM modem for sending and receiving SMS messages integrating such SMS communication into any control program in a simple robust and secure manner Nubitek SMS Manager is a library that is ready to be added to the STEP7 MicroWIN programming environment It consists of 3 functions and their use is extremely simple for each message that you wish to send or receive you simply need to add a segment to your control program Fields of application Nubitek SMS Manager offers numerous application possibilities
9. Receiving alarms or maintenance notifications to your mobile Consulting the status of a remote station Receiving production data Commanding an installation remotely Communicating by SMS between widely distributed stations And much more contact Nubitek Support online and we will study the technical feasibility of your idea Features Total control of the GSM modem The application takes full control of everything related to the management of SMS messages initialising and configuring the GSM modem sending outgoing SMS messages receiving and analysing incoming SMS messages configuring and managing port communication managing and recovering from incidents etc Sending SMS messages Nubitek SMS Manager manages an unlimited number of outgoing SMS messages to multiple destination telephones In order to send an SMS message all you need to do is indicate the basic parameters condition for activation text of the message and destination telephone number s The text of the SMS messages is freely defined in the Data Block the insertion of variables into the outgoing SMS messages is done automatically and the simultaneous alarms are managed with no losses whatsoever Receiving SMS messages The recognition of incoming messages is performed by using keywords to identify the message thus providing great flexibility Nubitek SMS Manager analyses the incoming SMS messages and provides notification if it receives a message that
10. a set of variables that the Nubitek SMS Manager application uses to provide information to the user or to receive instructions for a specific purpose It can be compared to the SM area for special marks of the S7 200 The area is stored in the V memory at the start of the area reserved for the library The exact position of each variable can be consulted on the table of symbols on the tab with the name of the library once memory has been assigned to the library These variables can be integrated into the control program for advanced use However although they appear in the table of symbols with a symbolic name they can only be used in the application with an absolute address this is a rule of Step7 MicroWIN due to the fact that they are internal variables of a library aig SITE Diecc n Comentario O O O OOOO O Ready wD System Ready to send and receive SMSs FFI Made VT 1 Part af the CPU in PPI made PFI Hequest WT 2 Request to set the port to PPI made END Teleservice VOLS Request to set the port back to normal made Low Signal Level VI 4 GSM Signal too low to ensure the communication FULL Licence wD 5 FULL Nubitek Kep used TEST mode VOLE TEST mode ERRUH VO Error or event acurred see Last ERROR field Last ERROR Wats Code of the last error or event detected SMS Counter Wet ad Counter of SS sent since last inrsialisatian Signal Level dBm of the GSM Signal gt 31dBr is OF Minutes LEFT Using TEST mode operatin
11. ager User Manual Test mode The test mode is configured by indicated a value of zero in the field where the Nubitek key is located in other words creating the parameter Nubitek Key 0 Hetwork 1 SM 5M5 Manager Ready F DD Figure 6 3 Test mode The test mode enables full use of Nubitek SMS Manager and enables as many tests or client demos as may be necessary There is only one limitation during test mode SMS management freezes approximately every 5 hours and the modem switches off In order to continue the tests all you need to do is switch on the modem again and restart the CPU If you would like to know when a test period is going to come to an end the field Minutes LEFT in the user variables area displays the number of minutes remaining until the end of the current test period How to obtain a Nubitek Key In order to obtain a key it is essential to indicate the IMEI number of the GSM modem you are going to use The application will only operate if the S7 200 is combined with the GSM modem declared Nubitek key can be obtained Through an automation equipment distributor indicating the IMEI of the modem with which it is going to operate Directly from the Nubitek website www nubitek com by purchasing a Nubitek SMS Manager licence online and obtaining the final usage key The FAQ section of the website contains further information about the purchase process and the management of licences and keys
12. and support Nubitek Support Nubitek s technical support service is comprised of extremely highly qualified experts We can help you during any stage of your IT Automation project in order for it to be completed successfully Initial stage tell us your idea we will study it and tell you how you can use our communications libraries to cover your needs Development stage any question related to the use of Nubitek Solutions libraries or what to do in order to obtain the expected result will be resolved by our experts Activation it is also essential to receive good support services during this stage We will answer your questions as soon as possible Nubitek s website provides code examples technical manuals and contact forms to help your development projects If you would prefer a customised project Nubitek Projects can develop one for you If you would like to receive technical support by phone please call Nubitek at 34 91 448 24 39 nubitek SUPPORT FAQ Nubitek s website also contains the answers to numerous questions related to our products licence management or simply knowing what to do when a fault occurs with a modem for which you have already obtained a password Answers to these questions and more can be found in the More Technical Information section of each product and also on the FAQ page of our website www nubitek com 29 29
13. arameters TXT_1 and TXT_2 String Keywords to be recognised in the incoming message They are entered directly as strings at the entrance for example activate and irrigatation WIT If you only wish to define one keyword TXT 2 must be left blank and the string must be empty SMS Rcv Bool Output bit that is activated when an SMS message is received containing the keywords Important SMS Rcv is only activated during one single program cycle It subsequently returns to 0 Value Real It collects the numeric value that has been captured from the incoming message and saves it in REAL format even if it is received in the SMS as a whole number It is an in out parameter Therefore the value remains in the variable after having received the message The use of this parameter is optional If you are not going to use it enter any unused position The same one can be used for all the calls that do not use the Value parameter Flexible recognition Receive SMS recognises SMS messages in a robust and flexible manner freeing the user from having to remember strict formats tis possible for there to be more text in addition to the keywords It locates the keywords in any order and position t does not differentiate between upper and lower case letters within the standard international alphabet It captures the numeric value whether a whole number or with decimal places from any position in the messa
14. ated and can be consulted from the control program itself in order for action to be taken The following is a list of the codes code disconnection of the PC PPI cable or loss of power supply to the modem ee ee The PIN forthe SIM card is incorrect PIN for the The PIN forthe SIM card is incorrect card is incorrect There is insufficient coverage to establish monio MM communication Incorrect Incorrect Nubitek key modem switched off w ILS modem switched off An SMS message has been received that does not L xs SES messsgs ras Baan TSCENSG PG docs nat OONOSDOND To Sm e ed to any defined model It Tt has not been possible to send the SMS correctly reason unknown not been Tt has not been possible to send the SMS correctly reason unknown to send the SMS correctly reason unknown The SMS exit buffer is full up to 7 SMS allowed in the queue The last SMS message has not been sent Test the modem has been disconnected Restart the CPU and the modem for an additional 5 hours of operation www nubitek com 26 29 nubitek sms Manager User Manual 12 Teleservice and management of port 0 Nubitek SMS Manager uses port 0 of the S7 200 CPU for connecting to the GSM modem The application handles all port configurations and also uploads the parameters to the modem for Teleservice support from a remote PC Important port 0 must be exclusively reserved for communication with
15. d the destination telephone numbers directly from the Data Block Right click on the line in which they are defined and select Define symbol The names of the variables to be inserted and the activation conditions are assigned in the normal way whether in the program or from the symbols table For example in the Data Block SMS ALARM The temperature of the oven is amp R degrees m Tel Maintenance 434600123456 And in the Send SMS function SMS gt amp SMS Alarm Tel 1 gt amp Tel Maintenance Tel 2 gt 0 Value gt amp T Oven Note if you wish to use symbolic notation in the Value parameter the symbol pointer amp T Oven for example must be entered directly If the absolute method is used VD2500 MicroWIN will convert it into pointer format amp VB2500 and it will not be converted to symbol www nubitek com 21 29 nu bi te K User Manual sms manager 10 Receiving SMS messages The Receive SMS function recognises an incoming SMS depending on one or two keywords It also permits the automatic capture of a numeric value contained in the text of the message Receive SMS must be used once for each type of different message that you wish to recognise There is no limit to the number of times it can be used The function must be called during all cycles using the contact SMO 0 Network 4 Receive SMS sMS_AcyveM1 3 Figure 10 1 Recognition of incoming SMS message Receive_SMS p
16. done as follows 1 Include an identifier at the position in the SMS text where you want the value to be inserted Depending on the type of variable and the desired format the identifier should be one of the following amp I for a INT variable amp D for a DINT variable amp R for a REAL variable it will be shown to three decimal places 2 Place the pointer to the variable in the Value parameter of the Send SMS function The following should be taken into consideration The variable indicated in the Value parameter must be coherent with the identifier that is included in the text Nubitek SMS Manager is unable to check this The pointer notation is amp in other words in order to insert the variable VW4000 for example the indicator must be amp VW4000 MicroWIN will automatically translate it into a byte position amp VB4000 but Send SMS will function correctly tis advised to make use of symbolic notation in order to facilitate the compression and maintenance of the program Example In order to send an SMS message containing the temperature of an oven Define the text in the Data Block and include the identifier for the value at the appropriate position VB1000 The temperature of the oven is amp R degrees If for example the temperature variable in REAL format is contained in VD2500 the Send SMS function is called and is informed of the pointer in the Value parameter www nubitek com 19 29 nu bi e
17. duction Figure 7 1 Simple example of Nubitek SMS Manager in use Segment 1 SMS Manager configures the modem and performs the full control of the SMS application It only requires the PIN of the SIM card In test mode Nubitek key 0 When it is ready it sets the output Q0 0 Segment 2 Send SMS when the rising edge of Alarm Stop happens sends an alarm SMS message to David s mobile Both message text and phone number are defined in the Data Block Segment 3 Receive SMS defines the keywords for the activation of the process When the SMS message active proccess is received the Start Production bit is activated www nubitek com 15 29 nu bi te K User Manual sms manager 8 SMS Manager the main function This is the main control and management block of the application and is essential for it to operate It needs to be called just once and executed in all program cycles before any other library function The best option is to make the call with the SMO O contact at the start of the OB1 Main Block Hetwork 1 SMS Manager SM SMS Manager Ready PF 00 0 Figure 8 1 SMS Manager in use SMS Manager parameters PIN STRING PIN code of the SIM card within the modem It is written directly as a string of 4 characters at the function call For example 2244 WIT If a SIM card is used with the PIN code deactivated the string is entered as empty Nubitek_KEY INT Numeric key that is supplied by Nubite
18. e power should be disconnected from the PC PPI cable in order for the new configuration to take effect To do so the cable must be disconnected from the CPU S7 200 port Once the lights on the side have turned off it can be connected again www nubitek com 10 29 nu bi te K User Manual sms Manager Connecting the Equipment The following steps should be followed for connecting the equipment 1 Insert the SIM card into the GSM modem The slot to be used for this is labelled on the modem as SIM and has a small yellow button to one side Pressing this button with a pointed object will cause the tray for placing the SIM card to eject It is important to ensure that this tray is re inserted correctly Insert the 9 pin male male adapter into the female serial port of the GSM modem Connect the antenna and the power source to the modem to the RJ11 socket Configure the PC PPI cable as indicated in the previous section Ul UJ N Connect the end of the PC PPI cable female to the modem using the 9 pin male male adapter The PPI male end must be connected to port 0 of the PLC S7 200 Warning the application will not function correctly if the PC PPI cable is connected to port 1 of the CPU 6 Connect the power to both pieces of equipment On some TC65 versions the On Off button needs to be pressed for one second Maii j rT he Figure 5 2 Connecting the equipment The GSM modem Port speed It is usual for
19. e the local modem in the normal way It is not necessary to configure the remote modem the application does it all automatically The following steps should be followed for undertaking remote Teleservice access 1 Send an SMS message to the telephone number of the remote station with the word teleservice This will make the station permit Teleservice access 2 Wait a reasonable amount of time 1 minute for example and proceed with the Teleservice access from Step7 MicroWIN as you would do normally 3 Once you send the SMS message you have a period of 2 hours access When this period ends the station will automatically return to SMS management mode If you are going to need more time consult Nubitek Support 4 When you have finished the maintenance tasks you can hang up the call and leave the station to return to normal operation mode itself when the two hour time period comes to an end If you do not want the station to wait the normal period of 2 hours but to return to operation mode as soon as possible Stay online when you have finished the maintenance task Open the table of symbols associated to the library Find the position assigned to the END Teleservice bit in the user variables area Open the status table and put it online Display the value of the END Teleservice bit which will be set to FALSE MicroWIN forces absolute addressing for this variable because it belongs to a library Enter the val
20. eason whoever uses a library does not need to worry about the internal operations within the library Nubitek SMS Manager is an example of a library Whoever uses it in their programs only needs to worry about the usage parameters such as the destination mobile number or the text The library itself handles the complicated task of managing the modem and sending the SMS message An important characteristic of a library is that it integrates itself into the development programming environment as an additional system function which enables the programmer to use it in any of his control programs with significant time savings in terms of development and with increased reliability How to Install the Library in STEP7 MicroWIN In order to be able to use the Nubitek SMS Manager tool the library must firstly be installed into the STEP7 MicroWIN programming environment 1 Download the Nubitek SMS Manager library from the Nubitek website downloads page 2 Open STEP7 MicroWIN 3 From the menu bar click on File gt Add or remove library STEP 7 Micro WIN Project ji Edit View PLC Debug Tools Windows Help New Ctrl N F Open Ctrl O mp Close Wom 03 fe O Save Ctrl S Save s EX SIMATIC LAD Set Password ER Se Import Export Upload Ctrl U Download Ctrl D Create Library Add Remove Libraries PROGRAM COMMENTS Network 1 Network Title Page Setup Print Preview Print Ctrl P Fi
21. g minutes remaining Last Value ALY Last Value captured from an incaming 5 MS 3 N USUARIO Simbolos UOF Nubitek SMS Manager v1 3 Figure 11 1 User variables area that can be found in the table of symbols Map of the user variables area Assuming that the area assigned to the library starts with VBn it is SMS Ready Read Bool VBn 0 0 Indicates that the application is ready to send and receive SMS messages During the initialisation stage under normal conditions it takes about 30 seconds to be set to 1 It is equivalent to the SMS Ready output of the main function PPI Mode Read Bool VBn 0 1 Indicates that port 0 of the CPU of the S7 200 is in PPI mode In this mode a connection can be made from Step7 MicroWIN whether via Teleservice or directly by disconnecting the modem and connecting the programmer to the port In this mode SMS management is temporarily disabled PPI Request Write Bool VBn 0 2 Bit for requesting the application to change port 0 to PPI mode Important No direct changes should be made to the SMB30 control field of port 0 By activating this bit the application makes the change in a controlled manner Connection can be made to a system input in order to facilitate access for the programmer without needing to put the CPU in STOP It is only necessary to activate the bit for one cycle The application will set it to 0 again when the change to PPI mode has been made www n
22. ge In the example shown in Figure 10 1 the keywords Activate and irrigation are defined Any of the following messages will be recognised activate irrigation ACTIVATE IRRIGATION www nubitek com 22 29 nu bi te K User Manual sms manager irrigation activate Activate the irrigation system Other characteristics If an SMS message fits two different models the SMS Rcv exit will only be activated for the Receive SMS function that is first in the program If you wish to save program memory the keywords can be defined in the Data Block and just the memory positions VB3000 and VB3020 for example can be entered as the TXT 1 and TXT 2 parameters Use symbolic notation and you will not lose program legibility Value capture example In the example shown below Receive SMS is configured to receive the irrigation activation instruction and the period of time to remain active Network 4 Recelve SMS Activate T SMS Hcv Start rigation irrigation Irrigation Time Figure 10 2 value capture from incoming messages For example when receiving the message activate the irrigation 35 minutes the system will activate the Start Irrigation bit it is set to 1 for one program cycle and will enter the value 35 0 in the variable Irrigation Time in REAL format and permanently www nubitek com 23 29 nubitek sms Manager User Manual 11 User variables area The user variables area holds
23. gure 4 1 Add library 4 Click on Add enter the directory where you downloaded Nubitek SMS Manager and select the nubitek sms manager vl1 3 mwl file of the library Once the library has been added click on Accept a Add Remove Libraries The following user created instruction libraries are included for use in your additional libraries available for use click Add and select the appropriat instruction library file wl If you no longer wish to use an included instru list below and click Remove Note that removing an instruction library fro the file from disk C downloads nubitek sms manager v1 3 mwl Figure 4 2 Select library www nubitek com 8 29 nu bi te K User Manual sms manager At this point the Nubitek SMS Manager library should now be installed This can be checked by accessing the Libraries icon on the operations tree the library folder should be displayed together with the 3 functions it consists of Libraries Nubitek_SMS_Manager v1 3 TT SMS Manager TT Send SMS TT Receive SMS Figure 4 3 library at the operations tree The library has been installed you can use these 3 SMS management functions as if they were MicroWIN functions Assigning Memory to the Library When you start to use the library functions on your project and always before loading or compiling it a memory range must be assigned to the library its internal management requires 771 bytes of V memory the locat
24. how to use the 3 functions of Nubitek SMS Manager for sending and receiving SMS messages Chapter 11 contains the list of variables that the library produces in order to provide more information and control to the user Chapter 12 explains how to access the CPU via Teleservice and how to perform the appropriate port control Notations used in this guide This document uses differences in print to identify the type of text as shown in the following table Print Use and examples Italics Menu options Example File gt Add or remove library Bold Important notifications for the reader Example Attention Monospaced File names and directory paths Example nubitek sms manager v1 3 mwl Text referring to program code Example VB2000 Alarm message www nubitek com 3 29 nu bi te K User Manual sms manager Contents 1 WHAT IS NUBITEK SMS MANAGER 5 DESCRIPTION 5 FIELDS OF APPLICATION 5 FEATURES 5 2 QUICK START AND APPLICATION EXAMPLES 6 3 MINIMUM REQUIREMENTS 7 4 INSTALLING NUBITEK SMS MANAGER 8 WHAT IS A LIBRARY 8 How TO INSTALL THE LIBRARY IN STEP7 MIcRoWIN 8 ASSIGNING MEMORY TO THE LIBRARY 9 5 HARDWARE CONNECTIONS AND CONFIGURATION 10 REQUIRED EQUIPMENT 10 CONFIGURATION OF THE PC PPI CABLE 10 CONNECTING THE EQUIPMENT 11 THE GSM MODEM 11 6 TEST MODE AND NUBITEK KEY 13 NUBITEK KEY 13 TEST MODE 14 HOW TO OBTAIN A NUBITEK KEY 14 7 PROGRAM FUNCTIONS INTRODUCTION AND EXAMPLE 14 DESCRIPTION 15 A SIMPLE EXAMP
25. ion of which can be defined by the user 1 Click on F e Library memory STEP 7 Micro WIN Project1 SIMATIC LAD Pym Edit View PLC Debug Tools Windows Help 3 New Ctrl N D A v P 1 Open Ctrl O E Iri res n K Close Fg sm 1 lt Tl Save Ctrl 5 EL 01 10 Save As ick Set Password r Import Export bk Upload Ctrl U Download Ctrl D Create Library Add Remove Libraries etwork Co Library Memory Page Setup Print Preview Print Ctrl P Figure 4 4 Library memory 2 Select the Nubitek SMS Manager from the window that opens if you have no other libraries installed it will be the only tab available 3 Click Suggest address and MicroWIN will indicate a range of free memory 4 If for any reason you would prefer to use a different range all you need to do is click Suggest address again or directly type in the desired start location Important user variables of the control program should never be included in this memory range used by the library 5 Click OK Library Memory Allocation Nubitek SMS Manager v1 3 The instruction library Nubitek SMS Manager v1 3 requires 771 bytes of global V memory Specify an address where this amount of V memory can be used by the library Click Suggest Address to use program cross reference to locate an unused block of the required size Suggest Address VB through VB770 Aceptar Cancelar Figure 4 5 Library memory
26. is situated and observe the coverage indicator on the display TC35i modem The TC35i modem will switch on automatically when it receives power The SIM card should be inserted or removed when the power is disconnected The modem indicator light has three different statuses Off the modem is not receiving power or has received an instruction to switch off Regular flashing 1 second on and 1 second off the modem is switched on and active but has not yet established a link to the mobile telephony operator equivalent to having a mobile telephone switched on but with no PIN entered Rapid flash every 2 seconds a link has been established with the mobile telephony operator this happens just after entering the PIN on the SIM card This is the mode in which the modem should operate and should be achieved a few seconds after activating the installation If this does not happen check the error code by referring to the chapter regarding the user variables area TC65 modem Version 2 0 of the TC65 behaves in exactly the same way as the TC35i Version 1 4 of the TC65 also compatible with Nubitek SMS Manager behaves slightly differently The indicator light is used to display the communication status meaning that it flashes when an SMS message is being sent or received In addition the modem does not switch on automatically once the power source and the ports have been connected the On Off button must be pressed for approximately one
27. k so that the library can be executed indefinitely In order to operate in trial mode enter a value of 0 It is written as a integer variable no quotation marks Ready Bool Output bit that indicates that the application is OK and ready to send and receive SMS messages During the initialisation phase and under normal conditions it takes about 30 seconds to be set to 1 It may be useful to apply it to any S7 200 s output in order to be able to easily note whether the application and the modem are operating correctly www nubitek com 16 29 nu bi te K User Manual sms manager 9 Sending SMS messages The Send_SMS function sends an SMS message to one or two destination mobile telephones It is used once for each different SMS message that you wish to send Hetwork 2 Send SM5 Figure 9 1 Send_SMS function gt Sending an SMS message to two mobile telephones Send_SMS parameters SMS Pointer to String Text of the SMS message that has been defined in the Data Block as a String variable The start point of the text is indicated in pointer mode using the amp pointer notation For example to send the SMS message defined as VB3000 ALARM machine stopped due to motor failure amp VB3000 is indicated It is advised to make use of symbolic notation in order to facilitate the compression and maintenance of the program Tel_1 Pointer to String Destination telephone number for the SMS message that has bee
28. mbers as can be stored by the Data Block The text of the SMS messages are defined in a flexible manner They can be as long as is necessary provided that they do not exceed 160 characters Any text is admitted however certain regional or uncommon characters may not be accepted by the modem or GSM operator It is recommended to check that such characters are sent correctly Nubitek SMS Manager enables numeric variables to be inserted into the text easily and automatically How to do this is explained further in the relevant section of this chapter The destination telephone numbers Must be defined using the symbol and the country code For example in the case of Spain prefix 34 telephone number 600123456 must be indicated as 34600123456 Telephone numbers from different countries can be used together in the same project provided that they are indicated with their corresponding prefixes Important The country prefix should not be included for certain countries and operators If the texts produce a failure when sending the SMS error code 32 it is advised to try changing the definition of the telephone number SHS texts VB3DDD ALARM machine stopped due to motor failure VBA4UDU Day production amp l items VB5UO0DU Oil LOW LEVEL ZZ Telephone numbers VBS100 34600123456 VB32U0U 34600654321 VB33UU 448880200100 Figure 9 2 Definition of the texts and telephone numbers in the Data
29. n defined in the Data Block as a String variable The start point is indicated in pointer mode using the amp pointer notation For example for the telephone defined as VB3100 34600123456 amp VB3100 is indicated It is advised to make use of symbolic notation in order to facilitate the compression and maintenance of the program Tel 2 Pointer to String Additional destination telephone number It is defined in the same way as Tel 1 and enables the SMS message to be sent to a second mobile number during the same operation If you do not wish to specify a second telephone a value of 0 must be entered Value Pointer Pointer to the position of the numeric variable that you wish to include in the SMS text automatically This can be an INT DINT or REAL value If you do not wish to insert any variables in the SMS text the Value parameter will not be used and must be entered as 0 Definition of the texts and destination telephone numbers Both the SMS text and the destination telephone numbers are comfortably defined in the Data Block as String variables Important double quotation marks must be used For example VB3000 ALARM machine stopped due to motor failure www nubitek com 17 29 nubitek sms Manager User Manual VB3SIOU 346000123456 Nubitek SMS Manager has no limitation on the number of SMS messages and destination telephone numbers It admits as many SMS messages and different telephone nu
30. nubitek sms manager www nubitek com Nubitek SMS Manager User Manual nu bi te K User Manual sms manager Nubitek SMS Manager v1 3 User Manual Last updated July 2008 O 2006 Nubitek industrial IT S L All rights reserved The information in this document belongs to Nubitek industrial IT S L hereinafter referred to as NUBITEK en adelante NUBITEK Authorization is granted by NUBITEK only fot the professional use of this document provided that the following conditions are met 1 indication that rights are reserved appears in all copies together with the present authorization 2 this document may be used for informative personal and non commercial purposes only and may not be copied or posted on any network computer or broadcast in any media and 3 no modification is made to this document All other uses are specifically prohibited NUBITEK makes no representations about the suitability of the information contained in the documents and graphics published on this website for any specific purpose All contets and graphics are published as is and without warranties of any kind This documents may contain technical inaccuracies or typographical errors Its contents are subject to periodic changes and updates NUBITEK may at any given moment make improvements and or modifications to this document www nubitek com 2 29 nu bi te K User Manual sms manager Introduction The purpose of this manual is to ex
31. plain how to install and use the Nubitek SMS Manager library to manage the sending and receiving of SMS messages from a Siemens PLC S7 200 device Nubitek Industrial IT S L Nubitek Industrial IT is an industrial software development company that specialises in the integration of automation systems with new information technologies Nubitek develops customised projects as wells as producing and distributing applications for general use with the Siemens PLC S7 200 device such as Nubitek SMS Manager Nubitek s corporate philosophy is to create software that is simple but powerful at the same time thus providing access to advanced industrial communication techniques via modem without the need to undertake any development work nubitek Who is this document for S7 200 programmers who want to use the Nubitek SMS Manager library to integrate the sending and receiving of SMS messages into their control projects Automation customers who are not experts in development for the S7 200 and who want to know something specific about the Nubitek SMS Manager library How is this document organised Chapter 1 explains what Nubitek SMS Manager is and the advantages it offers to the user Chapters 3 to 6 provide the guidelines for using Nubitek SMS Manager software installation assigning memory to the library minimum requirements equipment connections and how to obtain the Nubitek Key Chapters 7 to 10 provide detailed explanations of
32. t_ERROR Read INT VBn 2 0 Code representing the last error or event that has occurred which remains the same until a new error or event occurs The meaning of each error code can be consulted in the following section of this chapter SMS_ Counter Read INT VBn 4 0 Sent SMS message counter for the application This can be used to count the outgoing SMS messages in such a way that the recipient can know if the messages are being received correctly and in full Signal_Level Read INT VBn 6 0 Measured value of the GSM signal in dBm A value of over 91 dBm is sufficient Less than 95 dBm is very deficient Minutes_LEFT Read INT VBn 8 0 This is related to the test mode In normal mode this is set to 0 It is a decreasing counter that indicates the number of minutes remaining until the next time the application will freeze Last Value RCV Read REAL VBn 10 0 Contains the last value that was captured by a Receive SMS function This same value is also provided by the same function with the parameter Value www nubitek com 25 29 nu bi te K User Manual sms manager Error Event codes Nubitek SMS Manager provides a series of codes to help the programmer during the development stage and during maintenance The field Last ERROR in the user variables area stores the code representing the last error or event that occurred This field is updated every time the ERROR bit of the user variables area is activ
33. the GSM modem you should never try to create a network with additional elements Important the programmer should never try to control the port in any way that is external to the application This may cause conflicts and cause SMS management not to operate How to access the CPU from STEP7 MicroWIN The normal operation of the port under Nubitek SMS Manager control is in freeport mode This is necessary to control the GSM modem and the SMS application This mode is incompatible with Step7 MicroWIN access via the port whether directly or via Teleservice In order to access the CPU from Step7 MicroWIN via port 0 it is necessary for the port to be configured in PPI mode There are 4 ways to access the CPU Use a CPU with two ports and connect via port 1 in PPI mode Put the CPU in STOP this automatically sets the ports to PPI mode Locally request Nubitek SMS Manager to temporarily suspend SMS management and set the port to PPI mode in a controlled manner This enables the modem cable to be disconnected from the port and provides access with the programmer For more details refer to the relevant section of this chapter Request the application remotely by using an SMS to configure itself to enable Teleservice access via the GSM modem For more details refer to the relevant section of this chapter Remote access using Teleservice The Step7 MicroWIN modems wizard is used to configure the remote and local modems Configur
34. the modem to be factory packed with the port configured to 9600 bauds TC35i or to 115200 bauds TC65 If this is the case Nubitek SMS Manager will have no problem connecting to the modem The user will only need to connect it to the PC PPI cable If the port is not configured to one of these speeds Nubitek SMS Manager will be unable to connect to the modem If this happens you can try to change the port speed manually connect the modem to a serial port of a PC and open the HyperTerminal establish communication via the COM port at the corresponding speed and 8 data bits no parity 1 stop bit and no flow control In order to verify that a connection has been established type AT Enter You should receive an OK response The www nubitek com 11 29 nu bi te K User Manual sms manager command AT IPR 9600 sets the modem speed to a level that will enable Nubitek SMS Manager to communicate Coverage Nubitek SMS Manager indicates the coverage measured by the modem and writes this level in dBm to a location in the user variables range of the V memory If the signal level is not sufficient to guarantee operation this will be indicated by the corresponding error message and the low coverage bit will be activated See the chapter regarding the user variables area for more details The level of coverage during installation can be quickly checked by using a normal mobile telephone Place the mobile at the location where the antenna
35. ubitek com 24 29 nu bi te K User Manual sms manager END_Teleservice Write Bool VBn 0 3 Bit for requesting a return to normal operation mode from PPI mode This is used to indicate to the application that the maintenance tasks have been completed and that it can make use of the port and the modem again By entering a value of 1 in this variable a period of 90 seconds begins during which the bit will be intermittent Upon completion the change to normal mode occurs Low_Signal_Level Read Bool VBn 0 4 Indicates that the coverage level measurement reflects a low signal level for the operator below the threshold that ensures correct communication The measured signal value in dBm is shown in the variable Signal_Level Measurement is not performed continuously only when the application is restarted FULL_Licence Read Bool VBn 0 5 Indicates that a Nubitek key is being used and that the application will function permanently TEST_mode Read Bool VBn 0 6 Indicates that the application is functioning in test mode The application will freeze approximately every 5 hours The number of minutes remaining until the next freeze can be consulted in the variable Minutes_LEFT ERROR Read Bool VBn 0 7 Indicates that an error or event has occurred This bit is set to 1 for only one program cycle The code representing the type of error or event that has occurred is stored in the field Last ERROR Las
36. ue TRUE for the END Teleservice bit Do not force it just enter it for one cycle You will see that it becomes intermittent You have 90 seconds to disconnect after which the station will return to SMS management mode www nubitek com 27 29 nubitek sms Manager User Manual Local access via port 0 The user variables area provides the programmer with the PPI_Request bit so that Nubitek SMS Manager can change the port to PPI in a controlled manner The programmer can activate the PPT Request bit using a button or operator panel This should only be done during one program cycle The bit will remain active until the mode change is complete subsequently PPI_ Request will be set to 0 and PPI Mode will be set to 1 Once PPI Mode is set to 1 you have 2 hours of free PPI access via port 0 after which it will automatically return to SMS management mode During this time the SMS application will be suspended If you need more time consult Nubitek Support In order to return to SMS management mode before the period of 2 hours comes to an end you must act on the END Teleservice bit during one program cycle The END Teleservice bit will become intermittent for 90 seconds after which the port will be changed END Teleservice will cease to be intermittent PPT Mode will be deactivated and a few seconds later SMS Ready will be activated again www nubitek com 28 29 nu bi te K User Manual sms manager 13 Internet service
Download Pdf Manuals
Related Search
nubitek_sms manager_manual_v1.3_en
Related Contents
Catalogue produit FE 6" Rew HighEff Bravetti BCW17 User's Manual TITAN NetUSB-100iX4 USBServer_UserManual Overview of changes in firmware v4.0 Tristar ST-8064 Mod: LM/50-10 DE4 FPGA Development Board User Manual EKZ006600F_Dom_User_EN:NOTICE 0066 00B.qxd Weitere Informationen Copyright © All rights reserved.