Home
User Manual - Sensortronic Scales
Contents
1. UNI T CHARGE KEYS DESCRIPTIONS 0 Used to set the zero point to 0 00 Used as an ESC key Setup Mode T Used to enter a tare weight and used to cancel a tare weight Used to convert the mode as below WEIGHING gt pcs gt gt WEIGHT LIMIT ON OFF COUNT LIMIT ON OFF UNIT CONVERSION WEIGHING Used as an ENTER key Used to calculate a unit weight of a sample gt Used to enter next digit T Used to display average weight T A Used to have number up KEY DESCRIPTIONS PRINT key V Used to have number down o Used to tum ON or OFF the power OPERATIONS 1 General Weighing m The display indicates if the scale is at zero or if there is a tare entered into the scale by way of a ZERO and NET 1 n A LILI kg I ALI LI kg RE s Tum on the power When the display is notzero Place an item on the platter The display shows 0 00 though there is nothing on When the STABLE lamp is Make sure that STABLE and the platter press the ZERO on read the weight ZERO lamps are on key 2 Weighing with Tare m Tare is the weight of container being used for a commodity The TARE key subtracts the weight of the container Place the container on the Q Press the TARE key NET G Place an item in the platter lamp is on container Torelease the TARE function remove an item and oly
2. 30 000 kg Limit L 1000 pcs When the weight comparison function is set When the counting comparison function is set Cumulative Weight Sum Function DEP only WEIGHT WELCOME TO CAS DB 2 Label Caption DATE 07 30 2007 Date TIME 17 35 58 Time Weight 40 180 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg Weight 40 200 kg gt means that you cancel the weight right before Weight 40 200 kg this weight Weight 40 200 kg Weight 40 200 kg Total 401 980 kg Cumulative weight sum Count 10 times Aggregate times Please take a reference of page 12 cumulative weight sum for printing process details 17 Sample format DEP 50 Notice 4 kinds of Print forms should downloaded to the DLP Printer to use all the features and Function smoothly 1 Weight tare Date 2888 89 4 16 88 08 Net 1234567 kg mara eae ago kg X In order to use the above label format Barcode Gross 1234567 kg set as OFF and weight comparison function as OFF in SETUP MODE 2 Weight Tare Barcode Date 2008 09 24 16 09 19 X In order to use the above label format Barcode Net 1234567 kg Il 1 set as ON and weight comparison function as OFF in SETUP MODE Tare 21234567 kg Gross 1234567 kg 3 counting function 2008 09 24 15 25 51
3. LJ LJ LJ e e LJ LJ LJ e e e e LJ 0 9 9 9 0 0 0 09 0 0 09 6 06 6 9 90909099 MEMO MEMO 31 LJ LJ e LJ LJ e e LJ LJ e e e e LJ e e LJ LJ LJ LJ LJ e e e e LJ LJ LJ LJ LJ LJ LJ LJ e e LJ LJ LJ e e e e LJ 0 9 9 9 0 0 0 09 0 0 09 6 06 6 9 90909099 DB ver Bench Scale CAS CAS BLDG 440 1 SUNGNAE DONG GANGDONG GU SEOUL KOREA TEL_ 82 2 2225 3500 FAX_ 82 2 475 4668 www globalcas com Specifications are subject to change for improvement without prior notice 9002 DB2 LC33 6 2008 11
4. Weight 0 546 kg Quantity 28 pcs COUNT LIMIT SET VALUE Limit H 0 200 pcs Linit y 8 180 pcs X Quantity Comparison Functions should setas ON 4 Weight comparison function Weighing Function WEIGHT 2008 09 24 15 24 38 Weight 1234567 kg WEIGHT LIMIT SET VALUE Limit H 1234967 kg Limit L 1234567 5 2 Weight comparison functions should set as ON X When using DLP printer it could not print in the percentage mode 18 8 2 Auto Print To use auto print function you have to set printer menu to Pr in setup mode Refer to Setup Mode Table on page 20 Ifthe weight is stable it is printed out automatically And You can print out data every time pressing the PRINT key 8 3 Stream Print To use auto print function you have to set printer menu to Pr Str in setup mode Referto Setup Mode Table on page 20 Ifthe weight is stable it is printed out continuously 9 Battery Charge m Warning massage is shown when the battery voltage is very low m Atthis time charge the battery a charging battery only m The display will show a red lamp and the battery will begin a fast charge automatically Use only the ac adapter which comes with the scale Other AC adapter may cause damege 10 Unit conversion kg Ib oz 96 2 H B Press the MODE key until Use HOLD key or Press SET k
5. container from the platter and press the TARE key 3 Counting Mode m If you want to count parts first you have to set sample size Press the MODE key until the display shows PCSSET Make Q Press the SAMPLE key sure that PCS lamp is on If you have set sample size before then the display shows 10 the display shows T If you want to increase sample size press the SAMPLE key The display shows 10 20 30 40 50 100 150 and 200 every time pressing the SAMPLE key If you set sample size to 10 place 10 samples on the platter Ifthe display shows 1 the counting result may not correct LCD version Lack of Unitlamp is On Ifthe display shows LOW itis impossible to count samples because the unit weightis too small Refer to Table 1 Model DBi g DBi3Xg DBW150kg 0 413000 Range of Lack Single 292lak 20g 5g2lak2 10lak 201g Dy2lak gt 1g Dy 2lak gt 1g 1009 2Lade g Range of Lack Dual 19 21 201g Ag 2lak2 gt 01g 5g 2lade 01g 109 2Lack 21g 20g2Lark 2g Sg2lak 2g RangeofLow Otg2low 019 gt 10 01g Low 1g2low 1g2low Table 1 gt 5 n LI Place parts on the platter then the display shows the number of parts You can also use tare function in counting mode 4 Percent Weighing Mode m The weight is displayed as a percentage of the reference 99206
6. light is on 10 seconds Backlight pL30 Back light is on 30 seconds OFF Do not use back light Brightness NIS You can set backlight brightness Default 3 APoFF Donotuse Auto Power Off function Power tums to be off automatically when the scale is AP 10 not in operation over for 10 minutes Auto Power Off z Ap 30 Power turns to be off automatically when the scale is not in operation over for 30 minutes Power tums to be off automatically when the scale is AP 60 not in operation over for 60 minutes 20 WLMO HIGH Limit gt Weight 2 LOW Limit You will hear buzzer HIGH Limit lt Weight Weight lt LOW Limit WL M1 p Weight Limit You will hear buzzer WL 2 Weight lt LOW Limit You will hear buzzer WL M3 HIGH Limit lt Weight You will hear buzzer 7 HIGH Limit 2 Counting result 2 LOW Limit CLMO vou wil hear buzzer 5 HIGH Limit lt Counting result Coane CLM1 Counting result lt LOW Limit You will hear buzzer CLM2 Counting result LOW Limit You will hear buzzer CLM3 HIGH Limit lt Counting result You will hear buzzer Print out date day Date dy oFF Do not print out date day tion Print out time Time tiOFF Do not print out time LAof Do not print out label caption Label LAon Print out
7. 70 NET PEr SEE UL s UL s OR Press the MODE key until the display shows PErSE If you Ifyou wantto use container have set reference sample before the display shows 0 0 place itand press the TARE key 9 Place reference sample on the platter and press the SAMPLE key The display shows 100 0 Make sure that reference sample should be bigger than 3 of maximum capacity If itis lower than 3 of maximum capacity the display shows In this case increase the weight of reference sample and press the SAMPLE key Place an item on the platter then the weight is displayed as I of percentage of the reference Ce 5 Hold Function Weight Mode ONLY m Key hold Place an item on the platter and then press the HOLD key HOLD is shown on the Average weight is shown on display the display m After average weight display 3 times HOLD function will be release automatically m Auto Hold function ri ri GFF HH After weighing item Use TARE key to select remove all of the container one of Auto Hold function from the platter press Hold key 9 Press Hold key to save Place an item on the platter and exit to normal mode Then weight display will show Hold The Hold blinks for two times and then the average weight blinks continuously After remove the item of the platter place another item on the platter Then display will sh
8. INDUSTRIAL WEIGHING SOLUTION icp ver Bench Scale 2 m 2 lt gt Z gt E CONTENTS PRECAUTIONS 4 PREFACE ttes 6 NAMES AND FUNCTIONS 6 OPERATIONS 8 SETUP MODE 20 ERROR MESSAGES SERIAL INTERFACE 25 SPECIFICATIONS 26 HOW TO INSTALL DB H Series 27 ASSEMBLING THE DISPLAY OFDB II WALL TYPE 28 PRECAUTIONS Warning Precautions when installing the scale To ensure that you get the most from your scale please follow these instruction Do not disassemble the scale When any damage or defect occurs contact your CAS authorized dealer immediately for proper repair Do not pull the plug by its cord when unplugging Damaged cord could cause electric shock or fire E Do not step up on the scale with wet feet Platter becomes slippery Humid condition may cause incorrect reading Do not overload beyond the maximum weight limit To prevent from fire occurring Do not place or use the scale near flammable or corrosive gas Insert plug firmly to wall outlet to prevent electric shock Scale must be grounded to minimize electricity static This will minimize defect or electric shock To reduce electric shock or incorrect reading Do not spill water on the scale or place itin humid condition Use p
9. It means that time is printed out Press the SAMPLE key Press the HOLD A or Press the SET key to save to set up time 00 00 00 PRINT key to have is shown on the is shown on the display number up or down To enter display next digit press the SAMPLE gt key If you do not want to save time press the ZERO key 23 5 How to Enter Label Caption Maximum 24characters LA aff LH an LA meyer 1 1 5 1916 Press the MODE key until To print out label caption press the HOLD A key the display shows LA off The display shows LA on Itmeans that label caption is not printed out ve pope r u LLON L A 5 Press the SAMPLE key You can program label caption by pressing HOLD A or WELCOM TO CAS is shown PRINT key To enter next digit or previous digit press on the display in default the MODE or SAMPLE gt key You can enter alphabet or special character by pressing the TARE key When you enter special character STABLE lamp is on When you enter alphabet STABLE lamp is off LASAUE Press the SET key to save LA save is shown on the display If you do not want to save press the ZERO key 24 ERROR MESSAGES SERIAL INTERFACE GND 29 Error o Description Solution Display Ihe Er
10. O ORO when scale i Remove unstable facts not stable The Err 1 occurs when a current Er 1 Zero point has shifted from the last Please call your CAS dealer span calibration Er3 The Err 3 is an overload error Please remove the weight The Err 9 is no weight error When scale is in counting mode you must load the weight 7 Err 9 Please load the weight on your tray If you have no weight on your Scale you can see this error message i The 14 means calibration Er 14 range is not correct Please call your CAS dealer D Sub Connector 9 pin 25 D Sub Connector 9 pin SPECIFICATIONS 6kgO002kg 15000550 6kg0 002kg 15kg 0 005kg 30001 6lb 0 002b 1560 0056 30Ib 0 01Ib 1515 0 005b 30Ib 0 01Ib 6060026 3 000919 6000929 15 000g 5g 6 000g 2g 15 000kg 5g 30 0009109 tn om om om STABLE ZERO HOLD HIOK LO Ib oz PCS SUM kg Low Battery DC 12V 125A Adaptor GV 33AH Pb Battery 40 C 280 x370 x560 420x635x765 PRODUCT WEIGHT When Battery is charged for 12 hours BATTERY LIFE Approximately 140 hours Back light off MINIMUM VOLTAGE LEVEL TERMEN o THE BATTERY Notice Specifications are subject to change for improvement without notice 26 HOW TO INSTALL DB II Series POST PIPE INDICATOR POST BRACKET WIRE POST PIPE LOAD CELL WIRE BOLT M6 x 12 2EA PLATF
11. ORM ADJUST MODEL DB II Series Open the box with care because indicator is connected to the scale with load cell wire N Turn the post knob so as to fix indicator w Pull down the wire out of post pipe and insert the post pipe to the post bracket Refer to fig 1 4 Fasten the post pipe with two bolts Refer to fig 1 A long bolt should be connected to the upper side Insert the wire to the post pipe Refer to fig 2 3 If the scale is not properly level please adjust 4 leg adjusting bolt at the bottom of the scale so as to center the bubble of the leveling gauge X Note Place the scale on a flat and stable surface Inside the indicated circle 27 ASSEMBLING THE DISPLAY OF DB Il WALL LOAD CELL WIRE MACHINE SCREW FH M4x 10 4EA MACHINE SCREW PH M6x 10 1EA GROUND WIRE WASHER 6 LOAD CELL WIRE MODEL DB II Series 1 Attach head bracket to the display and fasten it with screws provided asshown in Figure 1 2 Connect both of grand wire and load cell wire to load cell connector at thebackside of display as shown in Figure 2 3 Fasten grand wire to the bottom of platform body with bolt as shown in Figure 3 28 MEMO 29 LJ LJ e LJ LJ e e LJ LJ e e e e LJ e e LJ LJ LJ LJ LJ e e e e LJ LJ LJ LJ LJ
12. ey and the display shows U or PRINT key youcansetwhich will display your last unit unit you want to use kg Ib oz Press the MODE key to go to the weighing mode X Tare Unstable when the display weight is not 0 when change is not working Leave the platter empty and weighing is at Zero and stable the scale should work 19 SETUP MODE 1 How to Go to Setup Mode Make sure that power is OFF While pressing the PRINT key press the POWER key The display shows U You can select each menu by pressing the MODE key and change the setting by pressing the HOLD or PRINT key Ifyou press SET key you will save current setting and finish this mode To finish this mode without saving press the ZERO key 2 Set up Mode Table MENU DISPLAY DESCRIPTIONS bon You can hear buzzer Buzzer boFF You cannot hear buzzer Pr oFF Donotuse printer Printer Pr DLP DLP50 printer interface Label Pr DEP DEP50 printer interface Ticket Pr key Manual print DLP DEP Print method Pr AUC Auto print when the scale is stable DLP DEP Pr Str Ptint continually when the scale is stable DEP Linefeed DEPonly LFI LF9 Linefeed BC on off Print out barcode on off br 48 4 800 bps Baud Rate i 9 600 bps br192 19 200 bps br 384 38 400 bps bLon Use back light pL10 Back
13. ion is deactivated Press the HOLD A or Press the SET key the Press the HOLD A PRINT key to have display shows 00000 PRINT key to have number up or down To enter number up or down To enter next digit press the next digit press the SAMPLE gt key SAMPLE gt key 15 Press the SET key the display shows CL ON If you set up LOW HIGH limit wrong CL will be shown on the display Then you have to set it up again For example LOW 00100 HIGH 00090 or LOW 00100 HIGH 00100 Press the MODE key to go to weighing mode Suppose that the High limit of 200 and the Low limit of 80 are set up In this condition gr lamp is lighted on if the weight is 120 8 lamp is lighted on if the weight is 220 and if the weight is 60 fe lamp is lighted on It beeps as fixed on User Setup Mode Referto Setup Mode Table on page 17 16 8 Print Out 8 1 Manual Print m You can print out data every time pressing the PRINT key You can setup print function depends on your need Refer to Setup Mode Table on page 20 Sample format DEP 50 Weighing Function Counting Function WEIGHT COUN WELCOME TO CAS WELCOME TO CAS DATE 07 30 2007 DATE 07 30 2007 TIME 17 35 58 TIME 17 35 58 Weight 0 000 kg Weight 40 200 kg 50 pcs WEIGHT LIMIT SET VALUE COUNT LIMIT SET VALUE Limit H 40 000 kg Limit H 2000 pcs Limit L
14. key to set up the display shows WL OFF activate this function the low value the display shows It means that weight limit display shows WL ON L000 00 function is deactivated ON ee 47 gt Press the HOLD A or Press the SET keytosetup Press the HOLD A or PRINT key to have high value the display PRINT key to have number up or down To enter shows 000 00 number up or down To enter next digit press the SAMPLE next digit press the key SAMPLE gt key 7 oe ur Press the SET key the display shows WL ON If you set up LOVWHIGH limit wrong WL ERR will be shown on the display Then you have to set it up again For example LOW 100 00kg HIGH 90 00kg gt High limit is lower than Low limit Press the MODE key to go to weighing mode 14 Suppose that the High limit of 70kg and the Low limit of 30kg are set up In this condition lamp is lighted on if the weight is 40kg lamp is lighted on if the weight is 80kg and if the weight is 20kg Fe lamp is lighted on It beeps as fixed on User Setup Mode Refer to Setup Mode Table on page 17 Press the MODE key until Q Press the HOLD A key to Press the SET key the the display shows CL OFF activate this function the display shows L00000 It means the counting display shows CL ON comparison funct
15. label caption dFno Default setting is released Default dF YES Everything is setup in default Italic Bold Default Setting 3X Select the DEP printer in the Set up mode LINE Feed Features are enable to use and if DLP printer is selected then Barcode features are enable to use However both Line Feed and Barcode features could not use at the same time 21 3 How to Enter Date d on dY an aisle Press the MODE key until If you do not want to print out date press the HOLD A key the display shows dy ON It means that date is printed out d b5fiuE G Press the SAMPLE key Press the HOLD A or Press the SET key to save the display shows PRINT key to have dysave is shown on the 00 00 00 number up or down To enter display and then the display next digit press the shows a day of the week If you SAMPLE gt key set up a day of the week wrong dy en is shown on the display ut SAGE ONES EE EE E You can change the day by Press the SET key to save If you do notwantto save pressing the HOLD A or Wksave is shown on the press the ZERO key PRINT key Ifyou setup display a day of the week wrong Wk en is shown on the display 22 4 How to Enter Time Press the MODE key untilthe 2 Ifyou do notwant to print out time press the HOLD A key display shows ti ON
16. ow average weight again If you don t want use auto hold function remove the item and press hold key Display shows Press tare key it will be changed AH off Then press Hold key Auto hold function will not operate 11 6 Cumulative Weight Sum The function of cumulative weight sum is to be showing the aggregate times and weight as adding the value of weighing a several times Even though power is off the scale stores data This function is only available in weighing mode Place an item on the platter 2 To add this weight press the SAMPLE key Make sure that SUM lamp is on G The display shows cumulative weight sum and aggregate times every time pressing the SET key The SUM key is flashed SUM 4 5 Sib ROM ee a To cancel last added weight press the SET key to display cumulative weight sum or aggregate times and then press the SAMPLE key The display shows S SUB You can delete cumulative weight sum or aggregate times Press the SET key to display cumulative weight sum or aggregate times and then press the ZERO ESC key To print out cumulative weight sum press the SET key to display cumulative weight sum or aggregate times and then press the PRINT key DEP only 13 7 Weight Comparison Function HI OK LOW 7 1 How to compare weight uL aFF Press the MODE key until Q Press the HOLD key to G Press the SET
17. roper Adapter Incorrect adapter could damage the scale Attention Make sure to plug your scal into the proper power outlet For maximum performance plug into a power outlet 30 minutes before the usage for warm up For consistent and accurate reading maintain periodical check by your CAS authorized dealer Keep the scale away from other electromagnetic enerating devices This may interfere with accurate reading Take the battery out when scale is not in use for long time Leakage from the batteries is hazardous Place the scale on firm and temperature consistent environment Avoid sudden shock to the scale Grab on the bottom of the scale when moving By adjusting 4 comers of the scale set the scale even using the built in scale leveling indicator PREFACE Thank you for the purchasing of CAS DB II series This series have been designed with CAS reliability under rigid quality control and with outstanding performance Your specialty departments can enjoy with CAS products We hope that CAS product meets your needs The user manual is designed to guide you to understand product operation and proper care of product NAMES AND FUNCTIONS OVERALL VIEW KEYBOARD LEVELING GAUGE Post Type Wall Type gt DISPLAY AND KEYBOARD CAS 17 5 Min 4009 e d 20g gt O NET SUM MOLD Lo
Download Pdf Manuals