Home
Is212 2 - ISGUS
Contents
1. knob module again C 9 2 Removal of transponders Attention In case of loss of one transponder all transponders have to be removed 9 2 1 Removal of authorised transponders GOLESI a1eaud ssa A9yY SNIAZ 1 Hold the service key in front oft he knob module A x gt green 2x An optical acoustic signal indicates that the programming mode is gt a activated possibly you have to wake up the knob module by A turning the knob Hold the authorised transponder in front of the knob module w A reaa The transponder will be removed B The programming mode will finish 15 sec after programming the last transponder Otherwise you can finish it immediately by gt reds 2x holding the service key in front of the knob module again C 9 2 2 Removal of all transponders 1 Hold the service key for the duration of the programming mode Ca green 2x 15 sec in front of the knob module Repeat this procedure within Pa 60 sec This will remove at the end of the programming mode all Pa transponders incl battery change and dismounting card except Within 60 sec for the service key A B After this all transponders can be authorised again as mentioned in point 9 1 The first transponder will be automatically saved as SRY 7 the battery change transponder the second one as the i dismounting transponder J gt green Pi T lt 15 sec 9 Seite 4 4
2. the batteries need to be replaced GOLESI zenud ssa AOEyY SNIAZ 7 1 1 3 step battery management Ce CF Phase 1 L An optical acoustic signal pops up during locking unlocking operation Phase 2 An optical acoustic signal pops up during locking unlocking operation It takes 5 seconds until the knob module is ready for opening closing Phase 3 The knob module does not read any authorised transponder To change the batteries the service key and the battery change card are needed 7 2 Low Power Adaptor Is6774 The low power adaptor combined with a 9V battery can be used to supply the knob module with power in case of empty batteries By clipping on the adaptor on the knob module please make sure that the two pins of the adaptor hit the two contacts on the front of the knob module A After that the knob module is supplied by the adaptor B 7 3 Changing batteries 7 3 1 Changing batteries with battery changing card Put the battery changing card in front of the knob module A The knob module gets in battery changing position Use the battery changing tool to remove the cover B Change the batteries no signal if polarity is wrong C Repeat steps 1 2 Put on the cover again D Put the battery changing card or an authorised transponder in front of the knob module to quit the battery changing position E Seite 3 4 User Manual ZEUS keyless Is2122 Iscus Stand 21 12 2010 8 S
3. User Manual ZEUS keyless Is2122 Iscus Stand 21 12 2010 1 Short description Is 2122 ZEUS keyless private knob module as double knob cylinder one side with electronic knob other side with mechanical knob cylinder case and knob in nickel plated brass includes mounting screw and batteries GG LESI a1eaud ssa A9y SNIAZ lt LA Si a Mechanical knob Cylinder case Knob module 2 batteries Mounting screw 3 Explanation of optical acoustic signals Function Signal acoustic _ Signal optical Explanation pictograms Silent mode Optical signal LED Start programming mode O Green LED blinks red or green Transponder programmed on o o e Bagh LED gleams red or green Trans onder with Toggle Acoustic signal Feaiure srg oh knob OO3sec 000 Green O short high sound Transponder deleted S Red coe long deep souna IR will be deleted 15 Sec Green All memory cells occupied ooo S Red End of programming mode O e Red Reading mode after wake up O Red Transponder not authorised S Red Transponder authorised O Green All day activation Toggle O e Green After battery change ee Green Red Coupling error O O Battery management Phase 1 00000 Osx Red O5 Sec Green Battery management Phase 2 oo0oo0o00 wu 5x Red Battery management Phase 3 4 Tec
4. ervicekey Is2350 For service operations and programming on ZEUS keyless private knob modules the service key is required to prove the authorisation 8 1 Servicekey damaged lost In case that the Servicekey is damaged or gets lost it can be replaced By submission of the System card a replacement key ls2352 can be ordered So please keep your System card safe 8 2 Servicekey replacement A Servicekey can be replaced by another one 1 Put the actual service key in front of the knob module until the programming mode is activated 2 Put the new service key in front of the knob module until an optical acoustic signal shows that the key is memorized 9 Programming ZEUS keyless private is a MasterCard based system The memory of each door can store up to 100 authorizations 9 1 Transponder authorization Hold the service key in front oft he knob module A An optical acoustic signal indicates that the programming mode is activated possibly you have to wake up the knob module by turning the knob Hold the transponder in front of the knob module B An optical acoustic signal indicates that the transponder is now authorised and stored To activate the Toggle function you have to hold the transponder another 3 sec in front of the knob module The programming mode will finish 15 sec after programming the last transponder Otherwise you can finish it immediately by holding the service key in front of the
5. hnical Data Dimensions Environmental conditions Dimensions of the cylinder for european Operating profile locks as per DIN 18254 temperature 25 C up to 65 C knob module 40x41 mm storage temperature 40 C up to 85 C mechanical knob Type A 29 5 x 20 mm i In and outside T B34 x20 mm mounting location x 9 When used outside please check the Power supply surrounding conditions Batteries 2 pcs type CR 2 3V lithium Battery durability ca 30 000 operations at 20 C 4 years when stored Low power opening anytime via ext battery power supply Seite 1 4 Iscus User Manual ZEUS keyless Is2122 Stand 21 12 2010 5 Mounting Dismounting 5 1 Dismounting 5 1 1 Dismounting with Dismounting card colcsl a1eaud ssa AeEy SNIAZ 1 Hold the dismounting card in front of the electronic knob module A A it may be necessary to wake it up manually by turning the knob module Knob module is in dismounting position now Turn the knob module until the emergency current contacts are in 9 o clock position B Dismount the knob module by coevally turning and pulling it C D 5 2 1 Mounting the cylinder case Remove the mounting screw and the existing cylinder case Insert the Is cylinder case and fix it with the mounting screw Important Verify that all parts are smooth running before mounting the cylinder case 5 2 2 Mounting the knob module with dismounting card knob module is already i
6. n dismounting position Mount the knob module by coevally inserting and turning it in the cylinder case A B To quit the dismounting mode hold the dismounting card or an authorized transponder in front of the knob module C Do step 1 and to as shown in 5 1 2 not necessary if the K v 6 Handling Closing with an authorized transponder e g transponder card tag key 6 1 normal locking unlocking operation Hold an authorized transponder in front of the knob module An optic acoustic signal shows that the knob module is ready for opening closing Turn the knob module to open close approximately 5 seconds after reading the transponder the knob module returns in standby mode 1x green 1x 6 2 All Day Activation Toggle 6 2 1 Enable disable all day activation Toggle Put a transponder in front of the knob module until 2 optic acoustic signals at intervals of 3 seconds show that the cylinder is toggled Attention The cylinder is permanently enabled now so the door can be opened closed without any transponder 1x green 1x 3 sec 1x green 1x To undo the toggle feature repeat 6 2 1 Seite 2 4 Iscus User Manual ZEUS keyless Is2122 Stand 21 12 2010 7 Batteries 7 1 Battery management indicator for battery empty The Clex knob module provides a battery management showing the batteries capacitance loss in 3 steps to indicate that
Download Pdf Manuals
Related Search
Related Contents
OM 402UNI - Adel Instrumentation Samsung HMX-F90WP Brugervejledning Samsung HM3700 User Manual guía para a eficiencia User`s Guide - Atlas Banka AD User Manual Omega HHT-1500 Automobile Parts User Manual Benutzerhandbuch RNAlater® Tissue Collection: RNA Stabilization Solution User Guide Copyright © All rights reserved.