1. Light On Off Control 2 MESH FILTERS a 3 10 3 4 x 15 Dishwasher Safe Aluminum Mesh filters 3 PUTTING IN THE MESH FILTERS a Insert the Filter into the unit at an angle Fig 3b b Pushthe Mesh filter upward Fig 3c c Snapinto place Fig 3c Fig 3b Fig 3c CLEANING amp MAINTENANCE WARNING AN To prevent the possibility of a fire and explosion do not use flammable liquids or solvents to clean the unit or any of its parts AN Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning A Please thoroughly clean the unit weekly 1 RANGE HOOD a Use household cleaner to remove grease or dirt from the outer shell of the unit Spray on wiping cloth or sponge and wipe in the direction of the grain to avoid scratching the unit DO NOT SPRAY DIRECTLY ONTO UNIT Stainless steel cleaners can help keep your rangehood bright and clean 2 MESH FILTERS Clean the Mesh filters regularly for the most efficient suction power Let it soak thoroughly in warm soapy water overnight wipe with sponge and rinse OR Mesh filters may be cleaned using residential dishwasher TROUBLESHOOTING TROUBLESHOOTING A Check to make sure all power sources are disconnected before starting any troubleshooting Safety gloves and glasses should be worn when working on the unit Serious injury or death may occur if safety precautions are not followe
2. verona User s Manual Under Cabinet Series VEHOOD3610 NOTE PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED This unit is designed for indoor residential use only DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT SAFETY WARNING Turn off power circuit at service panel and lock out panel before wiring this appliance REQUIREMENT 120VAC 60 Hz 20A Branch Circuit Please read this manual thoroughly before installing your range hood Store it in a safe location for when you need to reference it in the future TABLE OF CONTENTS SAFETY INFORMATION CONTENT CHECKS T sc Sd dio E b oca i ve utut dene MEASUREMENTS rer Ede tuta PREPARATION siad M MCI MI Se INSTALLATION M RE CIRCULATING KIT OPTION INSTALLATION een mnn OPERATION amp FEATURES sten erro e ae re tvm rr Mud CLEANING amp MAINTENANCE ehe tied REO oen v eddie e LAC TROUBLESHOO GING i iio ad ES Le o a dae oben o pl EE Sa PARTS LIST REPLACEMENT WIRING DIAGRAM deste e Eve Mao Pu Want cu d vu WARRANTY 7 CONTACT to etos bs Eu Ue pede ene QU ER es Verona Hood VEHOOD3610 can be installed using outside venting or by use of a re circulating kit HOOD SPECIFICATIONS 36 Wx10 Hx22 D 600CFM e Hood construction 430 Stainless
3. Spirit level Phillips and flat blade SS screwdrdivers Strain relief for junction cover Tp ECS 120V 60Hz 15 or 20 Amp 2 wire with ground Properly grounded branch circuit M MEASUREMENTS Fig 1a Keyhole 2 from Rear 16 from Center 10 from Rear Centerline Electrical Opening 1 78 from Rear 13 58 from Center 8ft Standard 36 PREPARATION 1 BEFORE YOU START NOT INSTALL IF DAMAGED RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED Confirm you have all parts and required tools for this installation Installation may take at least 2 to 3 hours from start to finish Minimize the number of duct elbows turns used to maximize hood performance Duct elbows should be no closer than 12 to each other further apart if possible At least two people are needed for installation Hiring a certified installer and electrician is recommended In some jurisdictions make up replacement air is required Check with your local building codes for more details 2 LOCATION Determine the exact location you want to install the range hood A centerline should be located on bottom of cabinet or soffit Distance between cooktop and range hood should be between 24 36 Fig 1b Range hood should be mounted at stated measurements to ensure performance and lifespan of electrical components For cabinets with recessed bottom securely fasten wood str
4. Steel e 120V 60Hz 3 0A SAFETY INFORMATION SAFETY INFORMATION A TO REDUCE THE RISK OF A FIRE ELECTRICAL SHOCK AND OR INJURY OBSERVE THE FOLLOWING e Unit is intended for indoor residential use only If you should have questions contact the manufacturer at the address or telephone number listed in the warranty e Incase the unit should need to be cleaned or repaired switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel e Installation work and electrical wiring must be done by a qualified technician in accordance with all applicable codes and standards including fire rated construction e Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e Because the unit is made of stainless steel it may contain sharp edges Be careful to avoid cuts and abrasions by wearing protective gloves during installation and cleaning e Before you begin to cut or drill into th
5. CUATE AND CALL 911 NEVER PICK UP A FLAMING PAN Doing so may result in serious burns and possibly spread the fire DO NOT USE WATER Grease fire must be extinguished before further action may be taken Using water will agitate the grease and may cause a violent steam explosion Use a Fire Extinguisher ONLY if You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You are able to safely control the fire with your back to an open 044 S 4 exit Based Kitchen Fire safety Tips published by CONTENT CHECKLIST 1 CONTENTS INCLUDED a 1 VEHOOD3610 36 hood assembly b 1 User s manual c 1 Black 6 collar amp 1 6 7 Transition d 3 Mesh filters e 1 Screw packet 2 CONTENTS NOT INCLUDED a Recirculation Kit Purchased separately b or 7 Metal ducting 3 TOOLS REQUIRED NOT INCLUDED Safety gloves Safety glasses Electric drill w starter bit Utility knife Spirit level Measuring tape Writing instrument pen marker pencil gt iS Aluminum or duct tape i Wire nuts TOOLS AND MATERIALS REQUIRED NOT SUPPLIED m AQ Hammer ae gt Duct tape Wire cutter stripper Key Hole Saw aep pe operated drill az Round metal duct ex 00 length to suit Safety glasses Wire nuts installation
6. X 631 254 3426 E mail info veronaappliances com Information subject to change without notice
7. d VEHOOD3610 Series 1 LED lights may need to be changed Contact LED Light Issue EuroChef or replacement bulb 1 Confirm that circuit breaker is ON Unit Lacks Power 2 All wiring is connected Unit making humming noise 1 Replace defective capacitor with new one Fan Blower Fails Call for Service Parts Replacement amp Wiring Diagram 14 PARTS LIST ron name Oo se ome p omm S ee eee ees hee pm o Optional DE 5 How to Order Parts Contact Eurochef USA 866 844 6466 or submit a service call at www veronaappliances com Accessories 10 Recirculation kit with Charcoal Filters 11 Replacement Charcoal Filters Parts Replacement amp Wiring Diagram LED Driver WARRANTY CONTACT US LIMITED WARRANTY Verona Hoods warrants its product against defects in material or workmanship as follows Labor For a period of one 1 year from the date of purchase if the product is determined to be defective Verona will attempt to repair the product at its option at no charge After the warranty period customer must pay for all labor charges During the labor warranty period there will be no charge for any work done on the purchased model All labor repairs are limited only to the installation of electrical components Parts In addition Verona will supply at no charge new or rebuilt replacements in exchange for defective parts for a period of
8. e wall verify that there is no electrical wiring or any other hidden electrical components e Ducted fans must always be vented to the outdoors e The unit must be properly grounded and installed at the recommended height before beginning operation e Toreduce the risk of fire use only metal ductwork FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS SAFETY INFORMATION EN Nxo REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE Regardless of heat level never leave any surface materials unattended while operating an open flame Always turn hood ON when cooking at high heat Depending on amount of usage clean ventilating fans and filters frequently Grease should not be allowed to accumulate on fan or filter For instructions on the how to clean see maintenance page Never leave surface units unattended at high settings Boil overs may cause smoking and greasy spillovers may ignite as result Heat oils slowly on low or medium settings Use proper pan size Always use cookware appropriate for the size of the surface element A TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVA
9. ground wire a ground must be provided by the installer Green or Bare Ground Black Hot White Neutral 4 Completion a Turn Power back ON from the Circuit or Fuse box b Activate blower and lights to confirm proper function c Remove ALL protective film from the exterior of your hood and filters Optional Recirculation Kit Installation Electrical Opening 1 3 6 Optional Recirculating Kit Purchased Separately from your Dealer Place Recircutating Vent under cabinet and mark position of holes allowing for unit to slide back in the keyhole slots 1 Drive screws into underside of cabinet leaving a protrusion Install metal vent to underside of cabinet onto mounting screws and slide back to rear wall Tighten Screws Fasten diverter to top of hood as shown by screwing 4 sheet metal screws provided into the pre dilled holes Follow Installation from page 8 Drive machine screws provided into underside of Recirculation Kit leaving a protrusion Install hood to underside of Recirculation Lit onto mounting screws and slide back to rear wall Tighten Screws Add additioal screws to back wall if neccessary Install Charcoal Filters to sides of blower inside Hood OPERATION amp FEATURES 1 EASY ACCESS CONTROL SWITCH from left to right 0 Sg Button 0 Fan Off Button 1 Low Button 2 Medium 01 2 3 x Button 3 High
10. ips on bottom sides of the cabinet so that it is level and can receive and support the screws which hold the hood PREPARATION Use Fig 1a and 1b on page 5 for measurements Electrical Opening 1 from Rear 13 from Centerline Center Line Fig 1C Cabinet Electrical 6 Diameter if using Collar ONLY 4 58 from back wall to center of cutout 18 36 cabinet 8 4 Diameter if using Collar Transition Damper 5 from back wall to center of cutout CABINET SIDE 3dIS L3NISYO Cabinet Top View Front of Cabinet Install wood strips to level if cabinet bottoms are recessed Cabinet opening for exhaust should be e 6 diameter if using collar ONLY e diameter if using collar 6 7 transition Place hood under the cabinet to be installed and mark 4 keyholes Cf to drill starter hole P edid INSTALLATION 1 UNDER CABINET OR SOFFIT INSTALLATION a Make sure all preparation steps are completed b Connect 6 black collar to hood 1 Using screws provided c If using transition connect transition with damper to 6 black collar wider part to front 2 d Secure collar and transition with sheetmetal screws and or duct tape for an air tight seal Do not impede damper movement 3 e Cutout hole for 6 or 7 diameter duct exhaust hole in cabinet or soffit per figure 1C Recommended attaching 6 collar amp 7 transition with damper to hood before
11. one 1 year After the warranty period customer must pay for all parts During the parts warranty period there will be no charge for parts You must provide the serial number of your unit for any replacement parts during the warranty period This warranty applies to products purchased and serviced in the United States only Verona will attempt to repair malfunctioning units prior to shipping a replacement In the case that a unit cannot be repaired and must be replaced Verona will not be held liable for removal or installation fees of the malfunctioning and replacement unit WARRANTY CONTACT US WHAT IS NOT COVERED BY MANUFACTURER WARRANTY 1 Damages resulting from any of the following Improper installation or maintenance b Anyrepair modification alteration or adjustment not authorized by the manufacturer or an authorized service dealer Misuse and or accidents Incorrect electric current voltage or power supply e Improper setting of any control Pressing multiple selections at the same time f Improper chemical cleaning commercial or industrial cleaning agents 2 Products purchased for use in a commercial or industrial setting such as in a hotel office restaurant or other business Damage resulting from natural disasters earthquake flood storm etc Aluminum Filters Charcoal Filters and Light Bulbs CONTACT US Verona 41 Mercedes Way Suite 25 Edgewood NY 11717 TEL 866 844 6566 FA
12. setting into place f Wiring Access hole in cabinet per figure 1C If not using a plug feed the wires coming down into top of the hood through the opening in the bottom of the cabinet For recirculation kit installation you must feed wires through recirculation vent before going into hood g Using the screws provided fasten 4 hood screws into cabinet or soffit at location identified DO NOT SCREW IN ALL THE WAY LEAVE 1 8 OF SCREW SHOWING h Liftthe hood up to the cabinet such that the screws protrude through the key holes on hood top Push hood back flush against the wall so that screws support hood i While holding hood tighten all 4 screws securely from under the hood j NOTE Install additional screws through the back or top for security 2 CONNECT DUCTWORK a Connect 6 or 7 metal duct to collar or transition Your METAL Exterior Exhaust Outlet Purchased Separately installed at the end of your duct run on the roof or outer wall of your home must include an integrated damper to block the intrusion of outside air into the home INSTALLATION 3 ELECTRICAL CONNECTION Electrical Connection can be done by installing an outlet in the cabinet and securing a plug onto the wires from hood or bringing wires into hood as shown below a Verify that power is turned off at the source b Make electrical connections with wire nuts Purchased Separately as shown If house wiring is not 2 wire with a
Download Pdf Manuals