1. completely filled you will return to the main menu The sensor will not have been calibrated Calibration lasts 20 minutes gt image 5 The display will show Is the T Mini placed outside image 6 Do not approach the T Mini image 7 Calibrating image 8 An asterisk will appear on the bottom line every minute After 20 minutes the display will read Calibration 400 OK image 9 and the con troller will automatically return to the main menu image 10 10 Notes 12 03 lay Play m eom
2. sensor on a wall near the CO2 source with a minimum distance of 50cm It is better to not place the T Mini directly over the CO2 source if the source can reach very high temperatures CO2 generator The T Mini must be placed approximately 1 meter above the floor For this use the enclosed fixing bracket ATTENTION make sure the light sensor the milk colored cap on top of the CO2 sensor can observe any light directly and is not obstructed by for example any shelves or fixings 2 Plug the CO2 source into the outlet of the T Mini controller 3 Plug the T Mini controller in to a 230V outlet 4 Ready TechGrow T Mini user manual OPERATING AND ADJUSTING THE TECHGROW T MINI CONTROLLER All the settings are adjusted using the Push amp Turn button PTB Enter the menu by briefly pushing the button An arrow appears on the left side of the display If you turn the button now the arrow will switch from CO2 set to CO2 and back again ADJUSTING SETPOINT push the PTB once photo 1 an arrow gt appears on the display in front of the value CO2 or SET turn the PTB so that the arrow is in front of SET photo 2 push the PTB again photo 3 use the PTB to place the arrow gt in front of SET photo 3 a blinking square and a line will alternately appear in front of the CO2 set value photo 4 you can set the desired CO2 level using the PTB photo 4 wait 5 seconds to confirm the new value the disp
3. 70 ppm or much higher than 430 ppm it is not necessary to calibrate the T Mini That is because the value of neutral clean outdoor air is between 380 ppm and 420 ppm A deviation of 5 is common with this type of measurement equipment Please keep that in mind when setting your CO values In case of a greater deviation calibration is necessary Please continue with the follow ing step TechGrow T Mini calibration procedure CALIBRATION MENU 1 2 3 4 Disconnect the power supply to the T Mini CO controller Reconnect the power supply after 20 seconds The display will first show the type and software version of the controller Next the calibration menu is shown image 1 after 5 seconds you will be asked if you would like to continue with the calibration Choose Yes image 2 If you do nothing or choose No the controller will return to the main menu without calibrating the sensor CALIBRATION PROCEDURE The calibration menu will guide you through the procedure step by step Please note step 5 is your last chance to terminate the calibration and return to the main menu without making any modifications gt CO calibration Continue gt image 1 Yes No gt image 2 Press the button for 10 seconds gt image 3 Wait 10 seconds gt image 4 Arrows gt will appear on the second line of the display If the button is released before the line is
4. WWW TECHGROW NL 1echGrow CONTROLLER Internal CO2 sensor amp light sensor Built in calibration function Easily installed BG EU Plug amp Play WES Built in min max measurement gt 2 gt TechGrow T Mini user manual Congratulations You have just purchased the TechGrow T Mini CO2 controller This TechGrow CO2 controller is very easy to use By far the best in its class thanks to its completely digital technique and its revolutionary Push amp Turn controls Special features Plug amp Play can be used in small to very large rooms Adjustable between 300 2000 ppm Built in calibration function to calibrate the CO2 sensor against outdoor air Extremely accurate internal CO2 sensor produced by SenseAir amp Sweden the absolute market standard in CO2 measurement Built in fan for optimal airflow This provides an accurate and fast measurement Overview of minimum and maximum CO2 value The sensor takes a measurement every second Turns the CO2 source CO2 generator CO2 cylinder on off using a 230V relay Memory in case of power outages for setpoint and hysteresis LED indicates when CO2 is being dosed The T Mini has a built in light sensor to automatically switch between Day Night settings Possibility to connect the TechGrow AM T a SMS module to remotely read the CO2 value of the CO2 Controller Installation 1 is recommended to place the T Mini with light
5. and when it reaches the set value the source will be deactivated again EXAMPLE The CO2 value is set at 670 The CO2 is set at 40 The current CO2 value of the room is e g 733 which is higher than the CO2 SET so the CO2 source is turned off The red light is now off The CC2 slowly starts to drop to 670 nothing happens yet Only when the CO2 level drops below the CO2 set minus the CO2 in this case 670 40 630 the CO2 source will be turned on and the red light will light up The CO2 level will start to rise and when the value of 670 has been reached the CO2 source will turn off again By adjusting the CO2 a calm and stable atmosphere can be created The factory setting for the CO2 SET is 700 and the CO2 at 50 AUTOMATIC DAY NIGHT SWITCH 1 During the night when the lights are off and when the light sensor detects no or very little light the CO2 source is ALWAYS switched off That is why it is very important that the light sensor can directly detect the light source Otherwise you would be unable to dose any CO2 during the day because the TechGrow T Mini controller would think it is night TECHNICAL SPECIFICATIONS Power supply 110V 230 Volt 50 60 Hz Consumption 3 Watt Range CO set 300 to 2000 ppm Range CO 10 to 200 ppm advice 50 ppm hysteresis bandwidth Measurement frequency 1 measurement per second FIXING BRACKET Every T Mini comes with a standard fixing bracket so it ca
6. lay will now automatically return to the main menu photo 1 TechGrow T Mini user manual ADJUSTING HYSTERESIS BANDWIDTH push the PTB once photo 1 An arrow gt appears on the display in front of CO2 or SET use the rotary button to place the arrow gt in front of SET photo 2 push the PTB again photo 3 and rotate to place the arrow in front of photo 4 push the PTB again photo 5 a blinking square and a line will alternately appear in front of the value use the rotary button to adjust the value photo 6 wait 5 seconds to confirm the new value the display will now automatically return to the main menu photo 1 TechGrow T Mini user manual RESETTING MIN MAX CO2 VALUES push the PTB once photo 1 an arrow gt will appear on the display in front of CO2 or SET use the rotary button to place the arrow gt in front of CO2 photo 2 push the PTB again photo 3 the display will now show the Min and Max values photo 4 if you push the PTB for 3 seconds the min max values will be replaced with the current CO2 level photo 5 If you do nothing the display will return to the main menu after 5 seconds photo 1 TechGrow T Mini user manual WORKING WITH THE TECHGROW T MINI CONTROLLER When the CO2 value of the room drops below the set value setpoint the CO2 source will be activated After a while the CO2 value will rise
7. n be easily mounted to a wall Use the included screws to screw the bracket to the backside of the T Mini and then mount the device to the wall WWW TECHGROW NL TechGrow T Mini CALIBRATION PROCEDURE i E iy M 1 4 all u 1 E LA com BE E N AVANV gt TechGrow T Mini calibration procedure The TechGrow T Mini comes with a unique calibration feature that allows you to calibrate the device in case of large deviations Only calibrate the sensor if you suspect a deviation Our experi ence has shown that the SenseAir sensors we use will function for two years without cali bration being necessary The sensors are calibrated with the utmost precision at the facto ry however it is possible that the sensor starts to show a deviation after a year of service and has to be calibrated again PREPARATION FOR CALIBRATION 1 Place the T Mini in a CO neutral environment 400 ppm such as a balcony or a backyard for at least half an hour or in well ventilated room for at least 8 hours that has not been visited during that period including by pets or other animals There should also not be any plants in the room Calibration is best done during daytime because the CO values will be closer to 400 ppm During nighttime plants and trees emit CO and the outdoor CO values will be closer to 450 ppm If the minimal value is not much lower than 3

Download Pdf Manuals

image

Related Search

Related Contents

US Robotics 125 Mbps Wireless MAXg Access Point  Fountain Cellar FCL046 Instructions / Assembly  SmartMetals 062.7300 flat panel floorstand  Manual de instalação para sifões  canbootloader_final.  安心サポート規約 - 株式会社EPARK  Manual de instalación y empleo para ventiladores de    AVG AntiVirus for Mac User Manual  guide_d362(PDF/846KB)  