XGB Pnet Master Expansion User`s Manual
Contents
1. PROFICON LS PROFIBUS DP Master Configuration Tool Config Up 1 XXGB File Edit View Configuration Communication Diagnostics Tools Window Help 6 Aim Topology selector Linear View s fer 5 e 33 03 E 03 503 Device list _ X E Configi Up 1 XXGB Config x Project explorer M al ke 024 3 GPL DTAA PROFIBUS DP NETWORK ANALYSIS SHEET DIAGNOSTICS MODE 8 Project Config L GPL RV2 3 Addr 000 XBL Au PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION Addr 001 GP amp GPL TR2A Config 2013 04 23 20 20 30 001 000 000 Project Config L amp GPL TR4A NO OF DEVICES LEGEND 4 Addr 000 XBL cg GPL ACBC 001 Master s 001 Slavefs MASTER SLAVE s OWNER ACTIV DeACTIV WDOG ON of DIAG EVENT Addr 001 GP GPL AVEC GPL DC4C GPL DVAC GPL D 2A C GPL D24a C GSD Viewer 1 Master properties ap General Information General Information Output window 1 Detail Information SR RE DEVICE DIAGNOSTICS Periodic General Settings Communication interval second s You may change this value in system option Transmitting order 16th Receiving event information AP Bus ARS Config Up 1 lt XGB gt USB NUM SCRL SRERERERER LS Industrial Systen F
2. 1 5 2 1 General Specifications 2 1 2 2 Performance Specifications 2 2 2 ChafracteriellS nsus eee eee E Rene 2 4 2 92 SUUCTULe or 2 4 2 4 Cable Specifications 5 53 5 355 55535555 535 5 5 5 2 5 2 4 1 Cable specifications 2 5 S t Anstallatiorb 3 1 ou Caull ns WANEN Handling 3 2 3 9 Precauttohs Tor InetallatlOI 3 3 9 9 dhstallauon OF Cable ed dee 3 3 S A From Sening 16 Opera ton CE RE 3 5 9 9 stallati onor INS prOOLGL eesseseeeseceneesneecneeshee SR AAA 3 6 99 1 Installalorvor 3 6 36 Test CCT AMON 3 7 6 1 Precautions for SyStem contigUratlorr redes eee 3 7 Chapter 4 System Configuration 4 1 System Configuration of Network 4 1 4 1 1
3. Figure 7 3 2 After reading I O information add Pnet module Select High speed link tab in lower end tab of left frame Double click High speed link 1 It can available to set the module type base no number slot no number and communication cycle Chapter 7 Program Example TESS e o _ CRAY MARR AE OT FSF BBG NOM See uTvZSDSSsADABAUWESEZEZSESSVNVYYTIOUgGaSDSOOOBDOSS N 3OOL Project 3 123 a Network Configuration 9 Unspecified Network gt HIGHMEC 18050 Cnet 5 HIGHIEC 18051 LAW FEnet 4 HIGHAEC ROS XRL PSEA a HIGHOGC 8053 XRL PMEC Tel High speed Link 03 NewPLC 10050 XOL CH2A W NewPLC 8055 XGL fMT System Variable x NewPLCOUGI CPUH Canet read HIGHXEC XG XECU Stop fip Giobal Direct Variables eh peed ik index Communication period settings period tvoe Project Output data settings in case of emergency CPU error Latch Clear Mast FLecentty Used bur bon Name CPU stop Latch Clear Figure 7 3 3 Screen of communication module setting 7 12 Chapter 7 Program Example Select the Pnet for module type position of current master communication module is set the base number and slot number Communication cycle is set free from 10ms to 10s It wil
4. _ Sor bye so _ 1s 5s 10s 244 by ie EE m 4e 85 Example The number of blocks which can be set per HS link cycle 2 5 10 20 50 64 64 2 It is necessary to calculate lead time of transmitting depending on the number of blocks and data size per block Because data receiving cycle is same with 1 which take 2545 to transmits per 1byte Chapter 2 Specifications 2 3 Structure amp Characteristics 2 3 1 Structure of Pnet I F module 1 Structure of XBL PMEC XBL PMEC 4 4 3 LED Display D O S Download S W ASS 4 2 Cable connection Division Color Action Description sun Gres Normal Initialize Completed Off Error Fatal error occurred Flickering Sorma status with CPU Off Error Errorin CPU interface On Normal At HS Link enable Green Flickering Stand by On Downloading throgh PROFICon at HS Link enable Fatal error of HS Link service occurred at HS link enable On mm Executing normal access with all slave devicess Green Flickering CLEAR service with slave device Input and output data is 0 On Off Off On n Communication with slave devices is stopped communication Off n Off n Off STATUS Green Flickering Autoscan ormal ystem Autoscan mode Flickering Disconnection with slave module on operating On Error No Confi
5. 004 Insert OO onc Cnm ce Figure 5 2 8 Slave module settings window Chapter 5 PROFICON Setting 5 2 3 Bus parameter In this chapter we will find out how to configure the network bus parameter of these Network bus parameter can simply change the communication speed or adjust the timing for communication parameter precisely Generally default value is used without change in the communication parameter timing Therefore this manual describes how to change the communication speed and more details can be found from PROFIBUS DP specification or software manual with careful consideration Since master only has the authority to configure the network bus parameter you should choose master from topology to activate the Bus Parameters item from the Configuration menu Select the activated Bus Parameters item to activate the bus parameter settings tab as shown below Bus parameter General Settings Input Mode standard Value Eaudrate 1500 kBits s Detail Settings sdr Baudrate n Bus Parameter Af Master Properties GA Slave Properties Figure 5 2 9 bus parameter settings tab Chapter 5 PROFICON Setting 5 3 Download and upload Network Configuration PROFIBUS DP Master is communicated through Network Configuration To do so there is a downloading function to apply the composed Network Configuration to the Master In addition the uploading function which is cor
6. C Topology selector Linear View EE Ele Es ih 21 08 18 m 29 53 f BA Hi E S Device list i Config1 X Project explorer 4x Master 3 A S GAL PUEC _ PROFIBUS DP TOPOLOGY DESIGN SHEET OSU Project Configl 2013 09 4 F a Ta Addr 000 XBL PMEC PROJECT NAME DATE Revision ERSION AUTHOR DESCRIPTION Ex XBL PMEC Contig 2013 09 25 20 54 45 001 000 000 e OF DEVICES LEGEND MASTER SLAVE m OWNER ACTIV DeACTIV WDOG ON WDOG OFF amp SV is Series 001 Master s 000 Slave s 1 GLOFA GM7 Slave 1 Drives S amp SV iS Series Slave 2 0 P Slave 1 Switching Device TT S 14 824 ptem Slave 24 1 0 7 GSD Viewer wp ons Master properties EE gs 5i General Information General Information Model Name PMEC Model Name PMEC Station Type r Vendor Nan Industrial s Ident 0 2 T gt 350 File Name LSISOOOA GSC 550 Revision 1 Output window q General Settings I ef Bus f Mast Sf Slave CAP NUM SCRL Figure 7 2 2 Insert Master module Chapter 7 Program Example Now the user should compose slave module It can be either to set it up manually or search slave module existing in current network automatically and set it up However at this time the GSD file of slave module to be composed should be in the GSD directory See Figure 7 2 3 of PROF
7. Pnet Smart 4 1 5 1 5 1 5 1 1 Main functions 5 1 5 1 2 Characteristics nise 5 1 5 1 3 Screen composition 5 2 5 1 4 GSD Register 5 2 5 2 Network composition through PROFICON 5 4 5 2 1 Master composition n n ne nnn nnn nnn nnn enne 5 4 5 2 2 Slave composition n ne nnn nnn nen enne meme 5 6 5 2 3 Bus nnn nnn nnn nn aa a E 5 9 5 3 Download and upload Network Configuration 5 10 5 3 1 Download Network Settings 5 10 5 3 2 Upload Network Settings 5 13 5 4 Diagnosis 5 14 5
8. CONFIGURATION MODE PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION Contig 2013 04 23 20 20 30 001 000 000 NO OF DEVICES LEGEND 001 Master s 001 Slave s i MASTER SLAVE OWNER ACTIV DeACTIV WDOG ON WDOG_OFF Output window v Ver 1 04 00 Done Erasing master memory space 100 percent have been completed Starting Binary e transmission 100 percent have been transmitted Done NUM Figure 5 3 4 Downloading completed Remark 1 After downloading PLC is needed to reset Chapter 5 PROFICON Setting 5 3 2 Upload Network Settings 1 Communication connection settings The method of connection settings can be referred from 5 3 1 Network Settings downloading 2 Network Settings uploading Conduct uploading by selecting Upload image from Communication menu At this time new project will be automatically generated and uploading is proceeded g pi h li 006 c gt Dt L 0 zi Output 2 IMMER Uploading binary image Starting binary image reception 54 percent have been received NUM MEE Figure 5 3 5 Upload status If uploading is completed Done message will be displayed on the output window Project topology will show the Network Configuration compositi
9. XGL PSEA 4 amp Slave 1 Ident System 002 17 A QU 4 E cPL TR2A B C Slave4 amp BIS S 60_2 p 1 cmm 0031 22 ESI iste minis EM SS ess General Information 1 3 GSD Revision 1 uem 004 A 006 xPL BSSA Slave6 EAT General Settings Station Type Slave Assigned Master Addr 000 XBL PME Vendor Name LS Industrial Systi AK Station Address 6 Ident Number 0x09F7 Description Slave6 GSD File Name XPLBSSA GSD Activate Device Activate GSD Revision 1 Watchdog Control Enable Detail Information Data Settings m Parameter Data Default PEU Module Data Checked OMNI ey eee mere rane ITEM 7 Detail Information Cfg gt Master device XBL PMEA is added on the network Config1 with address Cfg Slave device GPL TR2A B C is added on the network Config1 with address 1 Station Address Cfg gt Slave device GPL D22A C is added on the network Config1 with address 1 NEC Cfg gt Slave device XPL BSSA is added on the network Configi with address 1 MUI Bus Master Slave Pro CAP NUM SCRL LS Industrial System Sa Figure 7 2 9 Screen of Network Setting Completion Chapter 7 Program Example Bus parameters are to communicate with the Master and represent communication sp
10. GPL TR2A B C 001 Masters 001 Slave s MASTER SLAVE OWNER ACTIV DeACTIV wWDOG ON WDOG_ Slave properties ix Pe 8224 Ready Output window Cfg Master device XBL PMEC is added on the network Configi with address 0 Cfg gt Slave device GPL DTAA B C is added on the network Config1 with address 1 CAP NUM SCRL General Information Model GPL DT4A B C Station Type Slave Vendor Name LS Industrial Systems Co Ltd Ident Number 0x07B3 GSD File Name LGISO7B3 GSD GSD Revision General Settings Assigned Master Addr 000 XBL PMEC Station Address 1 Description Slavel Activate Device Activate Watchdog Control Enable Data Settings Parameter Data Default gt Bus Parameter Master Properties 9 Slave Properties ee Figure 7 2 4 Add Slave Module Manual Setting Chapter 7 Program Example Change the station number of the slave module in the Slave Properties window on the left bottom as seen in Figure 7 2 5 To activate this window select a Slave from the topology Slave properties AX 22124 General Information Model Name GPL DTAA B C Station Type Slave Vendor Mame LS Industrial Systems Co Ltd Ident Number Ox07B3 GSD File Name LGISO7B3 GSD GSD Revision 2 General Settings Assigned Master Addr 000 XBL PMEC Station Address 1 Description ave Activate Device Activate Watchdog Control Enab
11. 35 Normal Maximum Send maximum data size in stop mode Figure7 2 12 Setting Window to access to XGT CPU module Once communication is connected select Download Image from the Communication menu to download As seen in Figure 7 2 13 the Progress Bar shows download progress and setting Pnet module network are completed once download ends Before closing this tool save the current network project to recover the project later BP PROFICON LS PROFIBUS DP Master Configuration Tool Configi XGB e TAF m o File Edit View Configuration Communication Diagnostics Tools Window Help 5 ES d B Cv dx ca C Topology selector Linear View a3 3 53 t gag Project explorer nx Device list X E Config lt amp g GPL AV8C amp g GPL DV4C amp amp g XGL PSRA XPL BSSA 002 Slave1 Slave 0 Controller 1 HMI 3 XPO PSEA 00 Slave 0 NC RC P GSD Viewer EA 2 2 5 General Information Model Name XPL BSSA Station Type Slave 5 4 Project Config1 2013 10 01 0 amp Addr 000 XBL PMEC in 00 Out04 Slave1 In 01 Out00 4 Master properties General Information Model Name XBL PMEC Station Type Master Vendor Name LS Industrial Syst Vendor Name LS Industrial Syst
12. Figure 5 4 7 Network scan window This window displays information of slaves Users check out whether this information is matched to actual slave information If GSD file and I O information is not matched or there is no GSD file then obtain formal GSD file provided by the manufacturer of the slave and compose the Network by yourself If the scanned contents are correct then click OK button to check out the collected Network composition as shown below Chapter 5 PROFICON Setting LS PROHBUS DP Master Configuration Tool Config2 XGB File Edit View Configuration Communication Diagnostics Tools Window Help Gd 3 0 327 2727 39 1 Topology selector Linear View 8 OE 3 0 ODO Device list aX Confia lt XGR gt i X Project explorer E EJ Config lt XGB gt E Config j p eg GPL TR24 B C S GPL TR4A B C PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE 4 Project Config 2013 GPL AY2A C 9 Addr 000 XBL PME PROJECT NAME DATE Revision VERSION DESCRIPTION 3 Addr 001 XGL PSE GPL ACBC Config 2013 04 23 20 39 10 001 000 000 i Project Config 2013 GPL AVeC NO OF DEVICES LEGEND Sa Addr 000 XBL PME GPL DV4C 001 Masters 001 Slave s MASTER SLAVE m OWNER ACTIV DeACTIV A WDOG_ON WDOG_OFF L Addr 001 XGL PSE GPL DC4C XGL PSRA PL BSSA Slave 0 Valves Slave Controller gt SS OOO
13. General NO OF DEVICES LEGEND MASTER SLAVE m OWNER ACTIV DeACTIV WDOG ON WDOG OFF amp 9 SV S series 000 Master s 000 Slave s GLOFA GM7 Slave 1 Drives amp SV iS Series Slave 2 0 Slave 1 Switching Device 59 LA 824 Slave 24 VO 4 GSD Viewer ve News Bus parameter 4x Be i General Information General Settings Model Name Input Mode Standard Valu Station Type Baudrate 1500 kBits s z Vendor Name Detail Settings Ident Number Bit 200 350 File 4 m Tsdr 350 Revision lin tBit Detail Information Output window TORK x Bit d _ FEN m Slave CAP NUM SCRL Figure 5 2 1 XBL PMEC selected from the list of device If you drag amp drop the selected XBL PMEC on the topology sheet of the project window then the master is simply composed as shown below At this time the composed master information is also displayed on the project explorer 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi 8 File Edit View Configuration Communication Diagnostics Tools Window Help 5 ES bd eB C Topology selector Linear View E 9 8 aa sep Device list SA Ba Config1 J m mM mem m3 Project explorer REX Master 3 if GAL PUEC PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE
14. Master lt GSD Viewer Ax Bus parameter Be Bt General Information qim A 0 0 T XGL PSEA Slave 00 0 00 General Settings Input Mode Standard Baudrate 1500 kBits s Detail Settings Tsdr Output window Detail Information 100 percent have been completed Loading module information into slave 100 Percent have been completed Checking module information correctness s percent have been completed one f Bus Sf Mas GA Slav Config lt XGB gt USB Figure 5 4 8 Network topology collected and composed 5 18 Chapter 5 PROFICON Setting Remark 1 The following is a description of the exception cases that there are GSDs which have same PNO ID or there is no module 10 when you execute auto network scanning a If between the GSD file and the module are not matched add Scanned Module After then you can see the checked Select button In case of below the slave that Scanned Module is added can t be displayed properly In order to successfully open after copying sys folder under the PROFICON installation folder of the PC which is already auto scanned overwrite the file in same location that you want to open the project And open the project If you open project files that are already auto scanned in another PC If you upload images that are already auto scanned in another PC If you open it in another PC after
15. Project Config1 2013 09 a Cela DATE Revision ERSION AUTHOR DESCRIPTION S XBL PMEC Config 2013 09 25 20 54 45 001 000 000 Slave 2 General ND OF DEVICES LEGEND amp sv is Series 001 Master s 000 Slave s MASTER SLAVE m OWNER ACTIV DeACTIV wWDOdG ON OFF GLOFA GM7 Slave 1 Drives SV iS Series Slave 2 0 Slave 1 Switching Device LA 824 Slave 24 VO GSD Viewer AR Ix General Information odel Name XBL PMEC Station Type Master Ident Number Ox000A SD File 550 Revision Detail Information LSISOOOA GSI Ready cil 4 n Output window CAP NUM SCRL Figure 5 2 2 Compose XBL PMEC Master by drag amp drop 4 nm b Master properties ER General Information BL PMEC Station aste E vendor Name S Industrial 7 Ident Number 000A SD File Name LSISOOOA GSC D Revision General Settings Mast f Slave Chapter 5 PROFICON Setting If you change properties like station address of the master or description click Master Properties of the Configuration menu to activate the master property change tab as below PROFIBUS DP TOPOLOGY DESIGN SHEET reject iconfigr 2013 09 27 18 43 55 lilly Addr 000 XBL PMEC PROJECT NAME DATE Revision VERSION AUTHOR DESCRI
16. This describes on the product configuration of the XGB Pnet I F module 1 XGB Pnet supports only Profibus DP FMS PA are not supported and protocol conversion is available by the coupler 2 Support of the DP version 1 0 Periodical data exchange between the PLC and the slave device Node diagnosis module status specific channel diagnosis 2 DP V1 Asynchronous data exchange between the PC or PLC and the slave device integration of EDD and FDT fail safe communication alarm 3 DP V2 supports broadcast clock synchronization and time stamp HART upload download redundanc 1 3 2 Available number by CPU You can mount up to 2 Pnet module If possible mount the module in the basic unit for best performance of the communication module The following table indicates the available service type by the CPU When configuring the system apply this considering the number of the communication module Chapter 1 Introduction 1 3 3 Slave Device The Pnet I F module can be connected with Smart I O series and available product list is as follows tem Product 10 SENE Code Block type PLC ope Connected at the 120 0 7100 expansion part Block type TAA 47060010 rR ouput 2 0 18 sin owo7as_ eommunicaton oso rR ouput 9 Source owo7as_ eormunicaton imei TR 16 05 Sg nores ommuniaton EPL NVEC 1706028 analog vonage
17. 18 o GueG a Setimgs W x a 123 Change Modr Fy E 3 E a Network Configuration dh Bad a Unspecified Network 39 wee 5 Bi EOSO UTE at Compare wan PIC XBL PHEC E gi HIGHXEC 8051 Pe SR z 8052 NU Al MIGHNEC 8053 WBL Canine Redunaanr E High speed Link 0 8 B NewPLC 8050 XGL Q Camrmunicalsan module tiling X NewPLC 8055 XGL E ae p System variable Dhagnods ee T giu a PER D m 10109 Pan fon 8 2 b Safety Sognabure aj MewPLCOUI CBUH Canna _ D mc History B ee PLC earnings ab Global Deect Variables Skip E 7 A A Fault Lack s pm Project bign perd Link Save PLC m Madule Chamging Viuanrd pM ttt intermmaftan Fixed Bate Changing Wizard hain Basi E Mest flecendy Used u High Port Start Onie Editing Cmiec kernal Chit a k D Function Haee dy Write Maid Program Cote kernal Eth i FH Fe a D TL Sei nec he NM Fw TA ey Online 0 Chis Mania 2 Mariner 3 Venter 4 Cher Lure LIOTE Wwe 1 10605 e
18. Ident Number Ox000A E GSD File Name LSISO00A GSD Ident Number Ox09F7 GSD File Name XPLBSSA GSD GSD Revision 1 Output window GSD Revision 1 Detail Information Ver 1 00 00 Done l General Settinas Erasing master memory space 100 percent have been completed Starting binary image transmission 64 percent have been transmitted Pa 8f Master 8B Slave P LS Industrial Systems Config1 XGB USB CAP NUM 5 Figure 7 2 13 Download Process Chapter 7 Program Example 2 Setting automatically After setting and saving the Master module set access according to the methods After that execute Auto Network Scan in the Diagnostics menu to make the following screen appeared Input the Master s address and its communication speed and press the OK button Then the module begins to scan networks Network Scan Settings Master Parameters Detected Type Address Baudrate UK AXBL PMEC 0 1500 kbit s Cancel Figure 7 2 14 Setting of Automatic Network Scan Through the process above PROFICON refers to GSD file of the Slave module on the current network and the data size of the relevant module and the address of the sending receiving data supported by the module are automatically set Then the scanned results are shown as in Figure 7 1 16 Network Scan Detected Devices 1 master s a
19. Manufactured Date 2013 09 25 Device Yersion VO OL Device Number 00000004 Serial Number 00000007 Firmware Name Firmware Type ABT Firmware Version 1 00 00 Firmware Date 2013 09 25 Configuration D ate 2013 09 25 20 03 Configuration Black Size 32 Configuration Done Contigued Master Mode Communication Made Endian Made Big endian Figure 1 4 3 Checking the version of the module through the PROFICON 3 Check through the case label of the product The module information is attached at the external case every communication modules In case online connection is not available take a module apart and check the label in the module case Chapter 2 Specifications Chapter 2 Specifications 2 1 General Specifications General specifications of XGT series are as specified below in Table 2 1 No Specification Related specifications Operating LC 5 Storage temp 25 C 70C Operating gus humidity 5 9596RH no dew allowed Storage BUR humidity 5 95 RH no dew allowed For discontinuous vibration gt IEC61131 2 8 4 lt f lt 150 Hz 4 9ms 0 5G Max impact acceleration 147 ms 150 Impact Authorized time 11 ms immunity Pulse wave Sign half wave pulse Each 3 times in X Y Z directions Square wave AC 1 500V Test specification of impulse noise DC 900V LS Industrial Systems Static electric Voltage 4kV IEC 61131 2 discharging contact discharging IEC 61000 4 2 N
20. Monitor 1 L USB OK iT p Find2 Com Used Cross Dupli 1009 Figure 6 2 7 Read Information Chapter 6 XG5000 Setting In case that Pnet is installed in slot 3 it is automatically registered as below r m umo 0 gt gt XG5000 E Project Edit Find Replace View Online Monitor Debug Tools Window Help POS le EGQ INO O ooxB88x E amp 5 MMRRE amp caca rn Er cm HESS Lug E a R 4 4 AS AR 4P N IF CIE P v ner ny E F3 F4 ae rae F6 R4 F F9 211 sF3 sF4 sF5 sF6 F10 sF7 c3 4 9 123 4 3 Network Configuration 4 j Unspecified Network gj NewPLC 8050 XGL CH2A xy NewPLC 8055 XGL EFMT AB 3 5 8050 LHZ Cnet gt Py D45 XEC 8051 FEnet gt AB DASXEC 8052 XBL PSEA gt 5 B0S3 XBL PMEC a AE Variable NewPLC XGI CPUH Cannot read 4 al 4t XEC XGB XECU Stop Global Direct Variables B Parameter 03 euop Bojejea waysis Project View High Link View P2P Function FB Most Recently Used E Monitor 1 v 4 x Result Progam Variable Device IAIX i Monitor2 Monitor3 Monitor 4 Result 1 T Too TT REEL GET USB OK CES D M i Figure 6 2 8 Standard setting screen At this time if current information is di
21. Profibus FMS Fieldbus Message Specification solution generally used to provide communication functions in the cell level with services available to transmit the program file to operate the field device and its related data file to operate the program by remote control through the network and to manage various events which may occur during operation of the controlled and automatized system 2 Profibus DP Decentralized Peripherals Used to send real time data fast between field devices It is an example of the communication system applied as of HS digital communication type substituted for existing 24V and 4 20Ma of analog sign like the communication between field devices such as various sensors and actuators installed on PLC and the field 3 Profibus PA Process Automation Specially made for process automation with safety device built in which can connect sensor and actuator with a single bus line common used And it provides power and data communication function on the bus by means of 2 wire technology in compliance with the international standard of IEC 1158 2 4 SyCon Application program of Profibus Network Configuration Tool used to specify the configuration though SyCon and download the information onto the applicable module if LSIS master module XGL PMEA is applied 5 PROFICON Application program of Profibus Network Configuration Tool used to specify the configuration though PROFICON and download the information onto the applic
22. which may cause accidents from abnormal output or operation 4 Please install interlock circuits in the sequence program for safe operations in the system when exchange data with PLC or modify operation modes using a computer or other external equipments Head specific instructions thoroughly when conducting control operations with PLC Safety Instructions Safety Instructions for design process I O signal or communication line shall be wired at least 100mm away from a high voltage cable or power line Fail to follow this instruction may cause malfunctions from noise Safety Instructions on installation process Use PLC only in the environment specified in PLC manual or general standard of data sheet If not electric shock fire abnormal operation of the product may be caused Before install or remove the module be sure PLC power is off If not electric shock or damage on the product may be caused Be sure that every module is securely attached after adding a module or an extension connector If the product is installed loosely or incorrectly abnormal operation error or dropping may be caused In addition contact failures under poor cable installation will be causing malfunctions as well Be sure that screws get tighten securely under vibrating environments Fail to do so will put the product under direct vibrations which will cause electric shock fire and abnormal operation Do not come in contact with conducting parts in
23. 10 1 12 13 14 15 E ecima 00 o0 o0 oo oo OO OD OD OD OD Output Data 55 oo no OO o0 D oo oo 16 00 00 D D Update Figure 5 4 9 monitor 5 4 6 Disconnection Report This function shows the number of frequency of connection errors for slaves under data communication If you select Disconnection Report item from Diagnostics then the number of errors occurred are displayed in real time as shown below Disconnection Report Disconnection Count Device Address Address 000 015 000 O01 ooz 003 Count 0 5 0 0 Address 016 016 Of 018 019 Count 0 Address 032 O32 033 034 035 Count 0 0 0 Address 048 48 O49 050 051 Court Address 064 064 O65 OBB 067 Count Address 080 Count Address 096 Court Address 112 Count Figure 5 4 10 Communication disconnection report R means reserved station number from 124 to 126 address Although MAX station number can use 127 0 126 stations in the PROFIBUS standard Pnet module is able to use 123 stations So of 124 126 stations are meaning the areas that are not used Chapter 5 PROFICON Setting 5 4 7 Master information Device Information For the information of current master select D
24. 20 49 35 001 000 000 Rises toca EUN OF DEVICES LEGEND iem Slave 0 Valves 001 Master s 003 Slaves G masTeR BSLAVE ww OWNER ACTIV DeACTIV WDOG_ON WDOG_O E4 Addr 006 XPL BSSA Slave 0 Controller Slave 0 HMI Slave 0 Encoder Slave 0 NC RC Slave 0 Gateway Slave 1 PLC amp g XGL PSEA 3 Slave 1 Ident System Slave4 amp BIS 5 60 2 4 Tm H Se i xX Slave3 foe Slave properes 4x Ey General Information Vendor Name LS Industrial Systems Model Name XPL BSSA Ident Number Ox09F7 Station Type Slave GSD File Name XPLBSSA GSD Vendor Name LS Industrial Syst GSD Revision 1 Ident Number Ox09F7 I3 General Settings GSD File Name XPLBSSA GSD T Assigned Master Addr 000 XBL PME GSD Revision 1 Station Address 6 Detail Information E Description Slave6 7 Activate Device Activate P Watchdog Control Enable Output window RX Data Settings Cfg Master device XBL PMEA is added on the network Config1 with address 0 ms Cfg gt Slave device GPL TRZA B C is added on the network Config with address 1 Station Address oe Contig ER 1 Device s unique address Range 1 123 f Bus F Master Pr Slave Pro Ready CAP NUM SCRL Figure 7 2 7 Add Extended XPL BSSA Press module data in the Slave Properties window to make the
25. 4 Appendix A 1 Terminology A 1 A 2 List of Flags eoo rre errore e ne eens A 3 A 2 1 High speed link flags PROFICON Error code 5 A 4 External Dimensions Chapter 1 Introduction Chapter 1 Introduction 1 1 Introduction This users manual is to describe Profibus DP Decentralized Peripherals Master I F module here in after referred to as Pnet I F module among communication modules of XGB PLC system Profibus DP is specified in IEC Fieldbus Standard IEC 1158 In this communication Token Passing is used to control the communication and to configure the network easily Pnet I F module is a module to control the field bus with Twisted Shielded Pair Copper Cable applied Logical Token Ring between the Master Devices Active Stations Master Devices Passive Stations Slave Devices are polled 1 2 Characteristics XGB Pnet I F module has the characteristics as follows gt Conforms to the international standard of EN 50170 gt Supports Auto Baud Rate Detect gt Supports Sync Freeze mode gt Max input data 244 Bytes Slave gt Max output data 244 Bytes Slave Communication speed 9 6k 19 2k 93 7k 187 5k 500k 1 5M 3M 6M 12M Chapter 1 Introduction 1 3 Product Configuration 1 3 1 Model Name
26. 4 1 Start Stop Communication 5 14 5 4 2 Debug mode Start Stop Debug Mode Device Diagnostics 5 14 ZU OLIVE Lisee 5 eee en cee Sane een eee eee 5 16 5 4 4 Automatic Network 5 5 16 5 4 5 Data Monitoring 5 20 5 4 6 Disconnection 5 20 5 4 7 Master information Device Information 5 21 6 1 Parameter Setting Process ememem mmm 6 1 6 2 Basic Parameter Setting mm menm 6 2 6 2 1 Execute XG5000 and Create a new Project 6 2 6 2 2 Registration of the communication module 6 3 6 3 High speed Link Parameter Setting 6 7 6 3 1 Introduction of High speed Link 6 7 6 3 2 High Speed Link Send Receive Data Processing 6 8 6 3 3 High
27. 5 9 F9 F11 23 5 4 25 5 6 F10 5 7 c3 c4 Project 4 3 123 i A i 98 Network Configuration No Bye DE aisr 4 Unspecified Network gt 4 HIGHXEC 8050 LHZ Cnet gt 49 HIGHXEC 8051 LHZ FEnet 8 HIGHXEC 8052 XBL PSEA HIGHXEC 8053 XBL PMEC quf High speed Link 03 gy NewPLC BOSO XGL CH2A i gp NewPLC 8055 XGL EFMT Ry System Variable P 00 NewPLC XGI CPUH Cannot read 4 HIGHXEC XGB XECU Offline ah Global Direct Variables Monitor1 v 2 Result PLC Program Variable Device eu Result ST B E ST To T TT EE CELER ETT 0 100 Figure 6 3 2 Communication module setting 2 Config Upload Dnet Pnet After communication module setting you can use the menu of Online Communication module setting Config Upload Dnet Pnet In order to upload configuration data of master select Online Config Upload Dnet Pnet Safety Lock dy s i539 Safety Signature Change Mode gt Read E MM i aa Xx i i aR Compare with PLC 3 Set Flash Memory mec foonscesesscesamscassendgesondue renal L cec TEES MEI ENDE kd LS E M P Communication module setting gt 4
28. Config Upload Dnet Pnet menu Chapter 7 Program Example After PROFICON setting file is uploaded setting information is displayed in block window as shown below W HIGHXEC HS Link 03 d HIGHXEC Receive E Kis 4 Send t MEO a E CEU 0 Send Receive 22 55 Double click the applicable index to set the address Set M0200 for station3 M0000 for station 4 and M0300 for area to read M0311 for area to save of station 6 Figure 7 3 5 High speed link block setting W HS Link 03 al HIGHXEC X Figure 7 7 3 5 Finished screen After finish the setting setting information is downloaded in PLC Select Online Write parameter standard settings High speed link P2P Here Check High speed link to download and click OK Chapter 7 Program Example Sets Program Upload Prohibit Sets link enable with parameters HIGHXEC VED PLC Configuration I ET Parameter Program Network Parameter Standard settings E Cnet based slot vee FEnet based sloti be Pnet Slave slot2 Is High speed Link Taf High speed Link 0 internal El High speed Link 02 High speed Link 03 P2P O1 Internal 2 Internal Table 7 3 6 Write parameter Standard settings High speed link P2P After Write is finished the operation is by applicable high speed link enabled Select the Online Enable Link Hi
29. DT44 B C Of Add 000 Cancel Byte Ordered View Structured View Module Information Position Parameter Value Position Parameter Value Slot Module Name Byte HexaDec Decimal Byte Bit Decimal Description Value Selection 1 _ JisENERAL 000 1 0 2 001 0 0 2 1 3 002 0 0 3 2 4 003 0 0 4 3 5 004 0 0 5 4 5 7 7 6 8 8 g 001 Q0 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 002 0 0 18 1 19 2 20 3 Figure 5 2 7 Slave parameter settings window Slave module settings window is as shown below If a slave module is an expansion adapter such as XPL BSSA you can add the module to the expansion adapter by double clicking the module at the above module list If you add wrong one double click the item to delete it Slave Module Settings Current Slave Device slave Mame Assigned Master Name Add 001 GPL DT4A B C Of Add 000 XBL PMEC Cancel Module Selection Module Inputs Outputs Identifier 2 Byte Out 2 Byte In 2BYTE 0x21 0x11 2 Byte Out 2 Byte In 2 BYTE 21 0511 1 2 3 4 5 n B Input Data Byte Output Data Byte InfOutput Data Byte Number of Modules 001 001 General Information Input Output General Settings Slot Ids Configured Module Mame Add Len Add Len Module Description L 0 1 2 Byte Gut 2 Byte In BYTE 0 2 0 2 2 Byte Out 2 Byte In BYTE 2 002 002 002 Max 002 _ 004
30. Enable Link HS Link P2P EU Eee Upload Download File Diagnosis a ina 2 Force i Config Upload Dnet Pnet Skip Fault Mask System Diagnosis 77 Module Changing Wizard Base Changing Wizard m Gf Start Online Editing Ctri Q es Write Modified Program E lt End Online Editing Ctrl U Monitor 1 p nr Te Sn IT uium Figure 6 3 2 Config Upload Pnet 6 10 Chapter 6 XG5000 Setting The screen as below is after Config Upload Dnet Pnet You can use Read save area which are blank Send 0 2 Receive 4 Figure 6 3 4 High speed link block Setting 3 High speed link block Setting After uploading configuration data input device information in the blank area Classification Details Master Station No Display the Master station no 0 123 Station No 1 Setting range for the slave 1 123 Mode 1 Sending Transmit the data from master module t
31. GSD Revision Detail Information 7B4 General Settings GSD File Name LGISO7B4 GSD Assigned Master Addr 000 XBL Vendor Name LS Industrial Syst GSD File Name LGISO7B4 GSD Station Address 4 Description Slavel Output window Activate Device Activate Cfg Master device XBL PMEC is added on the network Config1 with address 0 Station Address Device s unique address Range 1 123 amp f Bus Bf Master Slave NUM SCRL LS Industrial Systems Figure 7 2 6 Topology after properties are changed Chapter 7 Program Example Set remaining GPL D22A through the process described above However for XPL BSSA as extended slaves it is necessary to add module data Set XPL BSSA on the topology first through the process above as in the following figure PROFICON LS PROFIBUS DP Master Configuration Tool Configi gt o File Edit View Configuration Communication Diagnostics Tools Window Help 5 e G Topology selector Linear View Bee 03 93 83 e aA 5 dd dj Sip Device list IX T3 Config v X Project explorer 4x GPL AV8C ail GPL DV4C PROFIBUS DP TOPOLOGY DESIGN SHEET uj project Config 2013 04 29 20 49 35 DATE Revision VERSION AUTHOR DESCRIPTION s M evision i a 004 GPL B a Config 2013 04 29
32. LX223 00140 on X224 LOO17F LX287 00180 Xo88 LOO21F LX351 _ 1_ _ 1_ _ 1_ k 000 063 _HS1_MODIk k 000 063 _HS1_TRX k k 000 063 _ 1_ k 000 063 _HS1_SETBLO Bit HS link parameter No 1 s all stations normally operated After _HS1RLINK is ON abnormal status displayed HS link parameter No 1 Block No k s general status displayed HS link parameter No 1 Block No k station s Run operation mode Normal communication displayed with HS link parameter No 1 Block No k station HS link parameter No 1 Block No k station s Run error mode HS link parameter No 1 Block No k setting displayed Description Displays all stations normally operated as specified in HS link parameter which will be On if 1 there is no error with all stations specified in parameter in RUN mode 2 All data block is in normal communication as specified in parameter 3 The parameter specified in each station itself is in normal communication Run link will be kept On if once On until stopped by link disenable This flag will be On if the station specified in parameter and the data block s communication status are as described below with HSmRLINK flag On 1 When the station specified in parameter is not in RUN mode 2 When the station specified in parameter is in error 3 When data block s communication status specified in
33. Len Add Len Module Description Digital Output 4byte BYTE 2 4 Digital Input 4byte BYTE 2 4 Analog Input 4Channel BYTE B 8 Analog Output 4Channel Analog Output 4Channel Analog Input 4Channel Digital Dutput 2byte Module Name Outputs Identifier mene Figure 7 2 8 Slave Module Setting Setting a network is completed See Figure 7 2 9 Now a bus parameter needs to be set r 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi File Edit View Configuration Communication Diagnostics Tools Window Help 5 E 9 e Cv kd ot Topology selector Linear View m 8 ia c3 03 83 a 3 3 3 HH Ed Sep Deke T Config1 X Project explorer 2 GPL AV8C ali amp 9 GPL DV4C PROFIBUS DP TOPOLOGY DESIGN SHEET AS Ee PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION oi se evision D E Config 2013 04 29 20 49 35 001 000 000 P is SU SEES OF DEVICES LEGEND Wc oriens GPI Slave 0 Valves 001 Master s 003 Slave s MASTER SLAVE OWNER ACTIV DeACTIV WDOG ON WDOG_O lily Addr 006 XPL BSSA Slave 0 Controller Slave 0 HMI m Slave 0 Encoder ha Slave 0 NC RC Slave 0 Gateway E gt 001 2 2 XBL PMEC 2zmm 000
34. No of all stations also shall be different from each other to use High speed link service 2 Use the communication cable as specified only If not serious error may occur to communication 3 Check communication cable if disconnected or shorted prior to installation 4 Tighten up communication cable connector until connected firmly If cable connection is unstable serious error may occur to communication 5 If remote communication cable is connected keep the cable far away from power line or inductive noise 6 Since the coaxial cable is not flexible it is to be diverged min 30cm away from the connector in communication module If the cable is bent at a right angle or transformed compulsorily cable disconnection or connector damage in communication module will be caused 7 If LED operation is abnormal refer to Chapter 9 Troubleshooting to check for causes and take actions against Contact service center if the error is as before Chapter 4 System Configuration Chapter 4 System Configuration 4 1 System Configuration of Network Communication system of Pnet I F modules is as shown below Master have to be set XBL PMEC the others have to be set slave modules To connect LS inverter with master module the inverter module have to attach Pnet option module If it is used with another company product GSD file provided by the maker is needed After GSD file is copied to GSD folder of Pnet configuration software tool and then if yo
35. Speed Link Parameter Setting 6 9 6 4 High speed Link Information 6 14 6 5 Monitor of High speed link information 6 16 Chapter 7 Program Example 7 1 Example of Communication with XBL PMEC 7 1 7 2 PROFICON settings 7 2 7 3 XG5000 settings Aai 7 11 Chapter 8 Troubleshooting 8 1 Symptoms and Management by LED Status poti E 8 1 8 2 System Diagnosis of PROFICON 8 1 8 3 System Diagnosis of XG5000 8 1 8 4 Diagnosis of Communication Module through XG5000 8 2 8 5 Troubleshooting mm mmm 8 3 8 5 1 PROFICON XG5000 abnormal connection 8 3 8 5 2 Abnormal connection with slave module 8
36. XBL PMEC 31 5 f moOdgasnNuuccOSOSOSaae 59 N J 09 Good Base No 00 Slot No 03 High speed link r index Communication period settings Period type 20 msec Output data settings in case of emergency CPU error D Latch CPU stop Figure 6 3 1 Communication module setting Module type Select Pnet module m Setting of base position installed Communication Base No Range of Setting 0 7 varying depending on the CPU module module settings Setting of slot position installed Slot No Range of Setting 0 11 Range of setting 10ms 20 ms 50 ms 100 ms 200 ms 500 ms 1s m 5s 10s default is 20 ms Communication Period type This applied to Send data But Receive data will be processed every scan end regardless of communication period Output data CPU Keeps its output status error Clears all outputs 9 CPU Keeps its output status emergency sto settings p Clears all outputs Table 6 3 1 Communication module setting setup in Chapter 6 XG5000 Setting After communication module setting you can see Figure 6 3 2 123 XG5000 i Project Edit Find Replace View Online Monitor Debug Tools Window Help DS amp BAX eka ma Qm AR e ARR AF AF 1S 4NF HET pf Esc F3 F4 sF1 22 F5
37. be parameterized ag Module Related Data Hex Value Decimal Item paa EE oa e d em edd Device Status3 Data overflow Reserved Reserved2 Reserved3 Reserved4 Reserved5 Reserved6 Reserved Channel Related Data Hex Extended Diagnostic Data Interpretation Using GSD Description Figure 5 4 3 Slave diagnostic Information 9 15 Chapter 5 PROFICON Setting 3 Stop Debug Mode Finally if you want to terminate the debug mode select Stop Debug Mode from the Diagnostics menu 5 4 3 Live List This is the function to display the information of the network which is under normal data communication If Live List is selected from Diagnostics then the live list window appears as shown below Live List Device Address 00 1 master s and 1 slave s are alive Figure 5 4 4 Live list If Update button on the right side is clicked then the contents of the live list will be updated 5 4 4 Automatic Network Scan This is the function to automatically scan all slaves physically connected to master through cable This helps to figure out the Network Configuration easily If you select Auto Network Scan item from Diagnostics then the dialogue window where the master address and communication speed are configured appears as shown below Network Scan Settings Master Parameters Detected Type Address Baudrate BL PME
38. caused by the user remodeling or repairing the PLC 4 Problems caused by improper use of the product 5 Problems caused by circumstances where the expectations exceed that of the science and technology level when LSIS produced the product 6 Problems caused by natural disaster 3 This warranty 1 limited to the PLC itself only It is not valid for the system which the PLC is attached to Environmental Policy LSIS Co Ltd supports and observes the environmental policy as below Environmental Management About Disposal LSIS considers the environmental LSIS PLC unit is designed to protect the preservation as the preferential environment For the disposal separate management subject and every staff of aluminum iron and synthetic resin cover LSIS use the reasonable endeavors for from the product as they are reusable the pleasurably environmental preservation of the earth LSIS values every single customers Quality and service come first at LSIS Always at your service standing for our customers http www lsis com m 10310001310 m HEAD OFFICE m LSIS Chengdu Office _ Chengdu China LS Tower 127 LS ro Dongan gu Anyang si Gyeonggi do 431 848 Korea Address 12FL Guodong Buiding No 52 Jindun Korea http www Isis com Road Chengdu 610041 P R China Tel 82 2 2034 4870 Fax 82 2 2034 4648 e mail cshwang Isis com Tel 86 28 8612 9151 9226 Fax 86 28 8612 9236 e mail comysb lsis com m LSIS Tokyo O
39. each module which may cause electric shock malfunctions or abnormal operation Safety Instructions Safety Instructions for wiring process Prior to wiring works make sure that every power is turned off If not electric shock or damage on the product may be caused After wiring process is done make sure that terminal covers are installed properly before its use Fail to install the cover may cause electric shocks Check rated voltages and terminal arrangements in each product prior to its wiring process Applying incorrect voltages other than rated voltages and misarrangement among terminals may cause fire or malfunctions Secure terminal screws tightly applying with specified torque If the screws get loose short circuit fire or abnormal operation may be caused Securing screws too tightly will cause damages to the module or malfunctions short circuit and dropping Be sure to earth to the ground using Class 3 wires for FG terminals which is exclusively used for PLC If the terminals not grounded correctly abnormal operation or electric shock may be caused Don t let any foreign materials such as wiring waste inside the module while wiring which may cause fire damage on the product or abnormal operation Make sure that pressed terminals get tighten following the specified torque External connector type shall be pressed or soldered using proper equipments Safety Instructions Safety Instructions for test oper
40. example of High speed link the master station O and slave stations 1 and 2 GPL RY2A GPL D24A are to share data with each other Setting is as follows 1 The master station O transmits 2 bytes of 000200 data to the slave station 1 2 4 bytes of the data received from the station 2 are saved on 000201 000202 e Station number 1 000200 gt Output Area e Mode Send e Read area 000200 GPL D24A station 2 Master e Station number 2 000201 Input Area e Mode Receive e Save area D00201 000202 H1 Figure 6 3 1 Block diagram of High speed link process Chapter 6 XG5000 Setting 6 3 3 High Speed Link Parameter Setting High speed link parameter setting is set in High speed link screen in XG5000 Communication module can be equipped with maximum 2 modules per a main unit in XGB 1 Communication module and Communication period setting If add the High speed link in the screen of project Communication module settings is opened In this screen communication module communication period and output data in case of emergency can be specified Communication modu eomm _ erT TTT TYTYY 7 GI Projet Gat Find Replace View Onine Monto Debug Too Widow Heis Communication module settings BS OCiVHcitiBOex th AY RARK SE 2 B e GHn2a2 2ngBoOogassitukges umotrti LA ran mh ee LJ j2a yewmsemnsgt www HOM ASSES err Module type
41. in the Type and specify the slot number Select communication module MewPLC Communication module f Number Figure 6 2 4 Communication module setting LEE La Q O i o have to register the communication module at the applicable base slot position of Standard setting Chapter 6 XG5000 Setting Selects Pnet I F module Communication Fixed 0 In case of XGB there is base module setting Slot Specifies the slot position of the module Setting range is different depending on the base type Table 6 2 2 Registration of the communication module you register the module at Slot 3 it becomes as follows ll ll 0 0 0 _ roe d PROFIBUS XG5000 18 Project Edit Find Replace View Online Monitor Debug Tools Window Help AE S O M A MOlOINse CRF WW 2 0 2 010 see 4S 4PE sc F3 F4 5 1 22 FS F6 28 sF9 F9 F11 23 5 4 25 5 6 F10 sF7 c3 of 4 8 PROFIBUS 4 9 Network Configuration 4 j Unspecified Network NewPLC BOSO Internal Cnet Fa NewPLC 8051 Internal FEnet 2 NewPLC B0S3 XBL PMEC ip System Variable 4 D NewPLC XGB XBCU Offline 103 Variable Comment 9 Parameter o Basic Parameter 4
42. link On condition is violated when Run link is On and will be off if the condition is recovered 3 Send Receive Tx Rx status HSxTRX 0 63 x HS link No 1 2 As individual information it shows the operation status of High speed link parameters on the register list up to 64 registered items Send Receive information If the Send Receive operation of the registered items is agreeable to the Send Receive period the applicable bit will be On and if not it will be Off 4 Operation mode _HSxMODE 0 63 x HS link No 1 2 As individual information it shows the operation status of High speed link parameters on the register list up to 64 registered items operation mode information just like the max register number If the station specified in the register item is in Run mode the applicable bit will be On and if in Stop Pause Debug mode it will be Off 5 Error _HSxERR 0 63 x HS link No 1 2 As individual information it shows the operation status of High speed link parameters on the register list up to 64 registered items error information just like the max register number The error displays the general status of the PLC which fails to execute the user program If the destination station PLC is normal it will be Off and if abnormal it will be On 6 High speed link status HSxSTATE 0 63 x HS link No 1 2 As individual information it shows the operation status of High speed link parameters on the register list up to 64 regis
43. slave module setting window appear Set modules in sequence through this setting window See Figure 7 2 8 Digital Output 4 Digital output 4byte XBE TN32A i E C a 2 ogam Digita input ayeee posz _____ Analoginput Analogue input aoyiexer anos 0000 output abyexBF Dvoan 8 JAndoguecuput amp bye XBF DCOAA _ Anelogue una Analog Output op _ 6 8 Digital Output a Analogue input 8byte XBF RD04A Digital output 2byte XBE RY16A Chapter 7 Program Example Double click a module from Module Selection to insert it to the setting table below Repeat this process until all of the wanted modules are inserted to the table To delete a module from the table double click the module to be deleted Slave Module Setting Current Slave Device Slave Name Assigned Master Name Add 006 XPL BSSA Of Add 000 XBL PMEC Cancel Module Selection 1__ Digital Input 1byte 2 _ Digital Input 2byte 3 Digital Input 4byte Digital 1bute _ B Output 4byte 7 Analog Output 4Channel 8 Analog Input 4Channel 8 10 Input Data Byte Output Data Byte In Output Data Byte Number of Modules 8 A 33 020 Max 032 022 Max 032 042 Max O64 007 Max 008 General Information E Input _ Output General Settinas Confiqured Module Name Add
44. system to be operated as specified in the following sequence Operation Sequence ww Install Pnet I F module on the base gt Check the applicable base slot position for correct installation Configure the system between Pnet module and slaves Use the exclusive Pnet cable for communication With power On check the LED status of the communication module Check if the interface of the communication module is normal with CPU opecify the configuration through PROFICON Configuration Tool gt Specify the module to be configured as Pnet master module and download it Download High speed link parameters gt Upload Config Upload Dnet Pnet from XG5000 set Send Receive parameters download High speed link parameters and let link enabled operation of the product Reset for XG5000 Use system diagnosis function in XG5000 to check the normal operation of the product bd Start Run 3 5 4 Chapter 3 Installation and Test Operation 3 5 Installation of the product 3 5 1 Installation of XBL PMEC Shield E a In case of start station and end station The other stations Figure 3 5 1 The method of Pnet cable installation Remark 1 Installation length of Pnet cable depends on the communication speed Refer to Table 3 3 2 1 How to install Pnet cable 1 Use Profibus DP cable 2 When slipping the coat of the cable be careful not to let the shielded line esca
45. 8 Parameter Internal Parameter 4 Scan Program 03 auopj Bo eje3 wais se lona afa m View High speed Link View P2P Function FB Most Recently Used Function Name Monitor 1 v x Result PLC Progam DeviceAVariable 1 Monitor2 Monitor3 Monitor4 Result 1 2 NewPLC Offline Row 0 Column 0 Overwrite 5 S a ee 9 2 Registration in the online status To connect Main unit need to set how to connect Select Online gt Connection Settings r Online Settings 9 3 Connection settings Type Settings General Timeout interval Retrial times Head Write data size PLC run made 5 Normal Maximum Bend maximum data size in stop made Figure 6 2 6 Connection setting screen Chapter 6 XG5000 Setting Project Edit Find Replace View Online Monitor Debug Tools Item Content Connection method RS 232C USB Connection Local Remote Connection setting option Local Direct connection between PC and Main unit Step of connection setting Remote Indirect connection between PC and Main unit through other communication module Time out 1 90 second General Retry 1 9 times Table 6 2 3 Contents of Connection setting window After connection if you select Online Diagnosis I O information it searches a
46. 8 oannes 098 22 Smart 1 0 Ox09F7 Extension XPL BSSA 147060130 Expansion type Pnet module type Remote Module XGL PSRA 47200128 Pnet Remote module Ox0C8 Communication XGL PSEA 47200132 Pnet Communication I F module OXOCBE Table1 3 1 Pnet module product list Remark 1 Fixed type The product whose terminal block is fixed at the module 2 Removable type The product whose terminal block can be removed Chapter 1 Introduction 1 4 Software This describes on the software tool for the Pnet I F module For programming and application refer to the followings 1 4 1 Check list for the software 1 Software list Programming tool XG5000 Communication configuration tool PROFICON 2 Selecting the CPU Version to use the Pnet I F module Available version v2 29 XBC Standard USB V1 32 High performance V1 53 Modular type V3 32 XG5000 V4 00 Software PROFICON XEC vit My 1 You can download the above software from our web site In case Internet is available visit the nearest distributor and get the installation CD Web site address http www lsis com 2 You can program through the RS 232C port and USB of the CPU module For the cable refer to wiring diagram of the CPU module 3 In case you use the product other than available version some function may not work properly If possible use the recommended version and check th
47. C 0 1500 kBits s Figure 5 4 5 Automatic network scan communication settings After setting up master address and communication speed click OK button to operate the auto scan as below Output NEM Transmitting order Analyzing Profibus Network 44 percent have been completed NUM Figure 5 4 6 Display automatic network scan operation status Chapter 5 PROFICON Setting Remark 1 Communication speed is shown by the speed of image downloaded And communication speed is shown by 1 5Mbps if there is no image downloaded Warning message will be incurred when you change the different speed from speed as shown window When you change speed some slaves couldn t be recognized As the time of speed detection is different depending on the slave 2 When auto scanning reading data is starting after waiting time as below Speed Waiting time After the automatic network scan is completed the slave list collected by master and information and GSD file information are displayed on the network scan window as below Network Scan Detected Devices 1 master s and 1 slave s are alive 002 022 042 062 082 102 122 Undefined GSD Detected Slave s Module Information ana Detected Slave IDs Detected Module IDs Modules Max Select PNO ID Model Name GSD File Name Module ID Module Name Inputs Outputs Module Slave OxOcbe GL PSEA LSISOCBE GSD 0 95 0x81 0 8 0589 0 64 Fixed on Co CH 4 whe
48. GK CPU User s Manual about XGK CPU module power module base IO module XGK CPUA CPUE CPUH CPUS CPUU specification of extension cable and system configuration EMC standard XGI CPUU user manual describing about XGK CPU module power module base IO module specification of extension cable and system configuration EMC standard XGR CPUU user manual describing about XGR CPU module power module extension drive base IO module specification of extension cable and system configuration EMC standard PROFICON User s Manual User s manual for Pnet configuration tool PROFICON XGI CPU User s Manual XGI CPUU XGR redundant series User s Manual Table of Contents Chapter 1 Introduction w 1 1 ke 1 1 1 2 Min 1 2 1 3 2 AVallable n rber Dy CPU en ei 152 1 9 lave DEVi E 2 2 9 1 3 1 4 1 4 1 C neck list for ine SOMW al 6 e e eee eoe een e de 1 4 1 4 2 PROFICON nn 1 5 1 4 3 Check the version nn nn
49. ICON installation directory The GSD file is provided by the company manufacturing such slave module mic Ls Industrial Systems mic PROFICON bmp ic bnr Cc dac 3 sys Figure 7 2 3 Directory of PROFICON Installation 1 Setting manually As in setting the Master module drag a selected slave from the device list on the left and drop it on the topology GSD File Repository GPL TRAA B C amp g GPL RY2A C amp GPL AC8C GPL AV8C GPL DV4C amp g GPL DC4C amp g XGL PSRA XPL BSSA GSD Viewer Ix SE General Information Model Name GPL DT4A B C Station Type Slave Vendor Name LS Industrial Syst Ident Number 0 0783 GSD File Name LGISO7B3 GS GSD Revision 2 Detail Information D 4 nm BP PROFICON LS PROFIBUS DP Master Configuration Tool Configi ee g S File Edit View Configuration Communication Diagnostics Tools Window Help 5s X 3a m Topology selector Linear View 3 3 Hd RH Sp Device list vix E3 Config1 X Project explorer amp GPL DCAC GPL DV4C PROFIBUS DP TOPOLOGY DESIGN SHEET project Configi 2013 09 27 18 43 55 Zo o PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION asd zi 4 evision f DTA SESE Config 2013 08 27 18 43 55 001 000 000 Addr 001 GPL DT4A B C ez NO OF DEVICES LEGEND
50. LI The frame length is smaller than 4bytes or bigger than D LENGTH 244bytes ERROR INVALI 19 If it is different between area code of command and DAREADCODE image upload ERROR_NOTAL LOWEDACCESS ERROR_INVALI If it is different between command type and image upload If block ID which want to upload is different from block ID 1 The the number of block ID which want to upload is bigger than the number of block ID of downloaded image D_BLOCKNO ERROR_INVALI DSEQNO D iN ERROR_NOMAT If the number of block ID of upload is bigger than the CH COMMAND number of block ID of downloaded image when the TYPE command of quitting image upload is arrived ERROR NOTCO M 2 If there is no downloaded valid image NFIGURED Image upload Communic MISC NOTSUP ation PORTED COM If you try to ask area code which is not supported Start Stop MAND ERROR_SLAVE 161 Debug _ADDR mode CON_NA 17 LIVELIST PARA EV M ERROR Live list LIVELIST COLLI If the slave station number is bigger than 123 If there is no slave or diagnostics information which is available If the master station number is bigger than 123 If the master station number is same with slave station number SION ERROR 2 4 Appendix If you try to ask area code which is not supported COMMAND a If you try to ask area code which is not supported execution ADDR i of auto If the communication speed is not supported ne
51. Linear View M m g Bi Device list Ax 29 Config1 X Project explorer 4x Master 3 S GAL PUEC PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE _ Project Config1 2013 09 SZ XGL PMEC PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION XBL PMEC Config 2013 09 25 20 54 45 001 000 000 Slave 2 General NO OF DEVICES LEGEND MASTER SLAVE OWNER ACTIV DeACTIV WDOG ON WDOG OFF amp 9 SV iS series 000 Master s 000 Slave s _ GLOFA GM7 Slave 1 Drives amp 9 SV iS Series Slave 2 0 Slave 1 Switching Device 59 LA 824 Slave 24 VO 4 GSD Viewer Bus parameter HER HB General Settings General Information Input Mode Standard Valu Baudrate 1500 kBits s z Detail Settings Output window Max tBit Detail Information CAP NUM SCRL Figure 7 2 1 Initial Execution Screen New Project Window For network configuration the master module XBL PMEC should be composed first Select XBL PMEC from the device list window on the left and drag and drop on the topology in the project window as seen in the figure below PROFICON LS PROFIBUS DP Master Configuration Tool Configi gt e T File Edit View Configuration Communication Diagnostics Tools Window Help 5 G bd
52. P NUM SCRL Figure 1 4 1 PROFICON initial screen 1 4 3 Check the version Before using the Pnet I F module check the version of the module 1 Check through the XG5000 This is method reading the communication module information through online connection If it is under normal interface with the CPU you can get the information as follows a Execute the XG5000 b Connect to the CPU through Connect on the Online menu c In the System Diagnosis screen select Module Information by double clicking the communication module and pop up window d You can check version of the module Chapter 1 Introduction Communication Module Information hows the general information of communication module Module kind Base number Se Slot number Station number pu s Hardware Error Hardware Version 05 Version Figure 1 4 3 Checking the version of the module through the XG5000 2 Check through the PROFICON This is method reading the communication module information through online connection If itis under normal interface with the CPU you can get the information as follows a Execute the PROFICON b Select Settings on the Communication menu More detail refer to Communication connection settings on the ch5 3 1 Download Network Settings Select Device Information on the Diagnostics menu d You can check version of the module Chapter 1 Introduction General Information Manufacturer
53. PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION I amp g GPL D22A C DATE Revision VERSION AUTHOR DESCRIPTION GPL D24 Config 2013 03 27 18 43 55 001 000 000 GPL DHAS OF DE ICES LEGEND GPL TR2A B C 001 000 Slave s MASTER SLAVE OWNER ACTIV DeACTIV WDOG ON WDOG_ Station Type Slave 003 Vendor LS Industrial Syst Ident Number 0x07B3 GSD File LGISO7B3 GSD Output window me Ready Cfg gt Master device XBL PMEC is added on the network 1 with address 0 Figure 5 2 4 Select slave from the device list CAP NU Simply drag amp drop the selected slave on the topology to complete the composition of slave See Figure 5 2 5 at this time it is confirmed that the slave is subordinated to the relevant master through the project explorer S GPL TRAA B C E amp g GPL RY2A C GPL AC8C F amp g GPL AV8C GPL DV4C 1 XGL PSRA amp g XPL BSSA GSD Viewer SBME General Information GPL DT4A B C Slave Model Name Station Type Vendor Name 15 Industrial Syst Ident Number 0 07 3 GSD File Name LGISO7B3 GSD GSD Revision Detail Information Ready BP PROFICON LS PROFIBUS DP Master Configuration Tool Config l c jme F
54. PTION Configl 2013 08 27 18 43 55 001 000 000 NO OF DE ICES LEGEND 001 Masters 000 Slave s MASTER SLAVE m OWNER ACTIV DeACTIV A wDOG OM WDOG_ General Information Model Name XBL PMEC Station Type Master Vendor Name LS Industrial Systems Co Ltd Ident Number Ox000A ont GSD File Name LSISO00A GSD GSD Revision 1 General Settings Station Address 0 Description Master0 Endian Mode Big Output window ee aio df Detail Information Cfg Master device XBL PMEC is added on the network Config1 with address 0 H Figure 5 2 3 Master property tab Chapter 5 PROFICON Setting 5 2 2 Slave composition The composition of slave can be done after the master is composed The method of composition for slave is same as the master Select the slave from the device list as shown in the figure below amp g GPL TRAA B C amp GPL RY2A C amp GPL AC8C GPL AV8C amp GPL DV4AC amp GPL DC4AC GSD Viewer 1 Model GSD Revision 2 GPL DT4A B C Detail Information 001 d xme EE 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi File Edit View Configuration Communication Diagnostics Tools Window Help 5 G bd EM ES bd 54 59 m Topology selector Linear View a al c ih xS amp g GPL DCAC amp GPL DVA4AC
55. Right choice for ultimate yield LSIS strives to maximize customers profit in gratitude of choosing us for your partner Programmable Logic Controller XGB Pnet I F Module Series _ User s Manual XBL PMEC A Safety Instructions eRead this manual carefully before installing wiring operating servicing or inspecting this equipment eKeep this manual within easy reach for quick reference 615 http www lsis com Safety Instructions Before using the product For your safety and effective operation please read the safety instructions thoroughly before using the product Safety Instructions should always be observed in order to prevent accident or risk with the safe and proper use the product Instructions are divided into Warning and Caution and the meaning of the terms is as follows This symbol indicates the possibility of serious injur NWarning dut rai iod or death if some applicable instruction is violated This symbol indicates the possibility of severe or N Caution slight injury and property damages if some applicable instruction is violated Moreover even classified events under its N caution category may develop into serious accidents relying on situations Therefore we strongly advise users to observe all precautions properly just like warnings The marks displayed on the product and in the users manual have the following meanings Be careful Da
56. SA Station 4 Staton 3 Staton No 8 Pli Figure 7 1 1 I O Structure and Sending Receiving Data Master ini eee QGPLTRAA Mo000 2byte XBE DO32A Receiving XBF ADO4A Receiving Sending 22byte XPL BSSA XBF DV04A Sending M0302 8byte Receiving 20byte XBF DCO4A vosoe soyte _ XBF RDO4A Receiving Moat7 ebyte XBE RYI6A Sending Table 7 1 1 High Speed Link Sending Receiving Map In the table above XBC H type main unit sends 2 byte data in M0000 area to GPL TR2A and 22 byte data in M0300 0310 area to XPL BSSA and saves 2 byte 16 points input data of GPL D22A in M0200 area of XBC H type main unit and 20 byte input data of XPL BSSA in M0311 3020 area of XBC H type main unit Chapter 7 Program Example 7 2 PROFICON settings To exchange data between the systems as in Figure 7 1 1 it is convenient for the user to write high speed link sending receiving map In addition it is necessary to write high speed link parameters after setting Network Configuration through PROFICON and download to PLC in order to send receive data as in Table 7 1 1 Once PROFICON is executed a new project window becomes active as follows 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi File Edit View Configuration Communication Diagnostics Tools Window Help 5 e B M ES d amp L3 Topology selector
57. SD file that is already registered is changed overwrite the GSD file to the gsd folder And then restart the PROFICON program after deleting the files under the sys folder PROFICON doesn t reinterpret GSD files every time for quick start So if you changed the GSD after loading you have to delete files in sys folder and then restart PROFICON PROFICON supports only one language for GSD files it support one filename extension In order to change the language select Tools System Options menu and then select Startup under Common Settings folder on the left side And change the GSD Type and select the path of the file When PROFICON is restarted the changes are applied Chapter 5 PROFICON Setting 5 2 Network composition through PROFICON 5 2 1 Master composition Master device is displayed on the top of the device list then select XBL PMEC as shown in the figure below 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi Lo 2 File Edit View Configuration Communication Diagnostics Tools Window Help 5 e B a S E xu Li Topology selector Linear View Y m g Bi gt Ne ewe Device list AX EJ Config1 X Project explorer Master 3 S G4L PUEC PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE amp jl Project Config1 2013 09 eg XGL PMEC PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION XBL PMEC Config 2013 09 25 20 54 45 001 000 000 Slave 2
58. XGI CPUH Cannot read 63 HIGHXEC XGB XECU Stop o Variables 03 auon 50 ejea View ques speed Link View P2P System information Allocation information Fixed Comment Function FB Base 0 XGB M12B Main Base 12 CPU XGB XECU Ultra High Perf 0 Slot 0 Internal Cnet Internal Cnet ng Slot 1 Internal FEnet Internal Ether Mle VOOM MAINA nn DZIA 1r1 rozessn nn Oz Sn n 1r r6 0441 4 m Lm T Monitor 1 v A x Result e Pogam Pe c gt Er p Findi Find2 Cross Used Dupli 100 Displays the information of communication module Displays the information of high speed link Displays the information of the slave configuration Table 6 5 1 System diagnosis Chapter 6 XG5000 Setting 2 Module Information Module kind ee cee UN EN i 1 5 Version Figure 6 5 2 Communication module information Displays the slot no 1 10 depending on main unit type Master Station no Displays the master station number Hardware status Displays the hardware status Hardware version Displays the hardware version Software version Displays the software version Table 6 5 4 Communication module information 3 High Speed Link r n Eg Standard information Total HS link information Base No 0 j The service is not set Slot No 3 Run link 0 L
59. able module if LSIS master module XGL PMEC is applied 6 GSD file As the data sheet of electronic devices it contains such information as maker device name status of released hardware and software Send rate available master related standards max slaves which can be connected with upload download option etc and slave related standards number and type of I O channels diagnosis test specification and available module information modular equipment is provided for 7 Broadcast communication Used to send the message whose operation station is not recognized to all the stations Master Slaves Appendix 8 Multicast communication Used to send the message whose operation station is not recognized to the station group whose operation station is previously specified 9 Token Ring As one of the node connection methods on the network it is a local communication network using a token to access to communication network with physical ring structure If the transmission node obtains a token and its control it transfers the message packet Actually realized examples are IEEE 802 5 ProNet 1080 and FDDI The term of Token Ring is occasionally used in substitute for IEEE 802 5 Token passing NM Dual Token passing Appendix A 2 List of Flags A 2 1 High speed link flags K type IEC YoLX1 00000 00001 00020 2 0005 LX95 00080 LOOO9F LX159 00100 X160 LOO13F
60. al Settings Communication interval second s You may change this value in system option Transmitting order 83rd Receiving event information A Bus Mas ARS Ready NUM SCRL SWWENNRNER LS Indu Figure 5 4 2 Slave diagnosis event occurs 2 Device Diagnostics In order to verify the diagnostic information of slave users should select the slave on the topology and select Device Diagnostics from Diagnostics menu to verify the diagnostic information like the Figure 7 6 3 Also if the slave is double clicked on the topology then the diagnostic information can be verified identically Device Diagnostic Current Slave Device Ident No Slave Name OxOcbe Add 001 XGL PSEA Diagnostic Information Device Status Parameter fault Invalid slave response Assigned Master Name Of Add 000 XBL PMEC Device Status2 Slave is deactivated in master parameter set 21 Reserved 1 Slave is in SYNC mode Slave doesn t support requested parameter functic 1 Slave is in FREEZE mode Config fault Station not ready for data exchange Station not existent Ident Number Assigned Master Address m irt E 1 Slave has extended diag data to report an error mp Ig Extended Diagnostic Information Device Related Data Hex Lors D ba CE S Position Data Group Byte Bit Binary WY Reponse monitoring Watchdog On W Always set to 1 Static diagnostic 1 Slave must
61. ation and maintenance 1 Don t touch the terminal when powered Electric shock or abnormal operation may occur 2 Prior to cleaning or tightening the terminal screws let all the external power off including PLC power If not electric shock or abnormal operation may occur 3 Don t let the battery recharged disassembled heated short or soldered Heat explosion or ignition may cause injuries or fire Do not make modifications or disassemble each module Fire electric shock or abnormal operation may occur Prior to installing or disassembling the module let all the external power off including PLC power If not electric shock or abnormal operation may occur Keep any wireless equipment such as walkie talkie or cell phones at least 30cm away from PLC If not abnormal operation may be caused When making a modification on programs or using run to modify functions under PLC operations read and comprehend all contents in the manual fully Mismanagement will cause damages to products and accidents Avoid any physical impact to the battery and prevent it from dropping as well Damages to battery may cause leakage from its fluid When battery was dropped or exposed under strong impact never reuse the battery again Moreover skilled workers are needed when exchanging batteries Safety Instructions Safety Instructions for waste disposal Product or battery waste shall be processed as industrial waste The waste may discha
62. ber Grstations per 32 including master amp repeater segment Cable used Electric twist shielded pair cable Max input size per slave 244 bytes Max output size per slave 244 bytes Max input size of master 15 616 bytes 64 station 244bytes station Max output size of master 15 616 bytes 64 station 244bytes station 10 20 50 100 200 500ms 1 5 10s Communication Reception DEM mE cycle Main unit scan x2 Data reception time Communication module scan d PROFICON XBL PMEC Dedicated Configuration Tool Internal consumed current 300 mA Weight g 86 Including connector 122 Table 2 2 1 Performance Specifications Chapter 2 Specifications Remark 1 Transmission cycle means the data cycle from main unit to communication module regardless of the cycle from master module to slave module it is necessary to consider scan time number of communication module number of set blocks communication data size per block when you set the transmission cycle It takes 25 per a byte when HS link data transmits from main unit to master module As it is based on serial communication So the number of blocks per cycle is limited and if the load is above it the cycle might be delayed more than you set Calculation formula is as below a Add the bytes of block within 1000bytes number of bytes Block data size 8 Block 2 data size 8 Block 1 data size 8 pack2 number of by
63. ct window Project Topology to compose PROFIBUS Network Project explorer otratify the configured topology on the project window in the order of Project Master Relevant Slave GSD viewer Detailed information of GSD of the device selected from the list Output window Action result of the Configuration Tool Master property window Set up property of master device composed on the project window Slave property window Set up property of slave device composed on the project window Bus parameter window Set up communication property of PROFIBUS Network composed on the project window 5 1 4 GSD Register After installation of XG5000 the folder was made as below m i PROFICON ic bmp bnr gsd it nri iy Sys Figure 5 1 2 Installation directory structure Chapter 5 PROFICON Setting bmp Bitmap storage place for use on the GSD file bnr Network Configuration binary image storage place gsd GSD file storage place provided by the Profibus DP communication module manufacturers prj Network Configuration project storage place sys Application configuration directory used by tool 1 How to register GSD files If the GSD file for the product you want to use is not registered follow the below steps to register GSD file Copy the GSD file to GSD directory And then copy bitmap image file used in the applicable GSD to bmp directory In order to apply GSD file restart the PROFICON program If the G
64. e gt Diagnosis gt Read lO information gt I O Sync Click right button in the project Add Communication module Specify HS link project 5000 window gt Add item gt Click HS link window Click HS link edit window Config Upload Dnet Pnet un Online gt Communication module setting gt Config Click HS link edit window Set HS link blocks 1 Send Set Read area from Main unit 7 11 HS Link 2 1 Parameter After double clicking block in the project 2 Read Set Save area from Main unit Write HS link parameters Online gt Write parameters Online gt Select Link enable gt Enable 1 HS link enable HS link x65000 Online gt Reset Table 6 1 1 Process of HS parameter setting Chapter 6 XG5000 Setting 6 2 Basic Parameter Setting 6 2 1 Execute XG5000 and Create a new project XG5000 is executed firstly And you can see the below the picture New project makes the method such as Project gt New project Mna tan maamaai aen onini iniu oaia Ta wanas wea M AS AMAR C a G of ag c x RARE i H pare aa E aE eee ee O iid d C XG 5000 cusees a gt Productnamen XGK CPUH X Auto allocation NewProgram Figure 6 2 2 Setting new project Writing the pro
65. e compatibility Chapter 1 Introduction 1 4 2 PROFICON PROFICON is software tool dedicated for Pnet I F module This is used for configuration diagnostics More detail refer to ch6 PROFICON The following figure is an initial screen of the PROFICON E PROFICON LS PROFIBUS DP Master Configuration Tool Co File Edit View Configuration Communication Diagnostics Tools Window Help 3 ES ed iP S bd 3 Topology selector Linear View e is We e usu Device list LX E Config1 X Project explorer LX Master 3 S G4L PUEC pij PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE Z Project Config1 2013 09 em XGL PMEC PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION XBL PMEC Config 2013 09 25 20 05 43 001 000 000 Slave 2 General NO OF DEVICES LEGEND MASTER SLAVE OWNER ACTIV DeACTIV amp WDOG ON WDOG_OFF amp SV is Series 000 Masters 000 Slave s _ GLOFA GM7 Slave 1 Drives amp SV iS Series Slave 2 0 Slave 1 Switching Device 59 LA 824 EJ Slave 74 1 0 m 1 Le GSD Viewer Bus parameter ax eg 8 HE General Information General Settings Model Name Input Mode Standard Valu Baudrate 1500 kBits s Detail Settings lt m a mm Tsdr File Name 250 Revision 0 Output window Detail Information tBit Ready CA
66. e technology of our company can read and restore the Network Configuration downloaded to the existing Master 5 3 1 Download Network Settings 1 Communication connection settings In order to download the Network Configuration composed on the topology window to the XGB Pnet Master module first of all you should set up connection to XGB main unit If you select Settings item from the Communication menu the window will be popped up as seen below Here you should select Communication with XGT and enter the information with current XGL PMEC module and click OK button Communication amp etlings Communication with GM4C O As MC Communication Parameters Communication with SGT PHOFIBUS DP Master Module Position Base Number slot Number 0 Settings PROFIBUS OP Master Module Position Base Number slot Number 0 Figure 5 3 1 Communication Settings window Information of XBL PMEC settings Then XGB connection settings window will pop up as shown below If a user clicks OK button by selecting the settings connected by the user then the connection settings will be finished 1 When the master is absent on the PROFICON screen if you select Communication Settings it can t know whether GM4C master or XGT master So after determining what kind of master you use select Communication Settings and then you can see the pop up window related to the master Chap
67. ection error on PROFICON XG5000 PROFICON XG5000 connection error Is the serial port setting correctly Yes Is the serial port used in other program No NO Is power supplied to module Yes NO Is the CPU module normal Yes No Is there a problem in Serial cable Yes NO s the environment appropriate with standard specifications Yes Ask to Customer Service Center Yes Set the port of serial cable connected with communication module Close the serial port in other program Connect the SyCon again Apply power in module Check the CPU module Check the serial cable Operate in environment prescribed at standard specifications Chapter 8 Troubleshooting 8 5 2 Network error with slave module Abnormal connection with slave module No Is High speed link parameter setting correct Check the High speed link parameter Yes No Check Power slave module and master module Is Power supplied on slave and master module Yes No Check the station address of slave module and SyCon station address Is the slave station address setting duplicated Yes No Is there a problem in serial cable Check the serial cable connector Yes Is the cable specified cable No and long length Check the cable type and length in product specifications Yes Ask to Customer Service Center Appendix Appendix A 1 Terminology 1
68. eed and communication timing parameters To set select the Master from the topology and then select Bus Parameters item from the Configuration menu to activate the Bus Parameter tap on the left bottom At this time it is possible to set communication speed Baudrate of the Master module Our Slave module Smart I O series have a function to adjust the speed of slave to be equal with that of the Master module automatically For other companies Slave modules refer to their user s manuals General Settings Input Standard Value 1500 kBits s Detail Settings Tsdr Baudrate zm F Mas Sf Slav Figure 7 2 10 Select a communication speed of the Master module If the process above is completed it can be declared that setting all of the networks is completed To download the Network Configuration to Pnet module select Settings from the Communication menu and set access After assigning a number to the slot in which the current Pnet I F module is installed set access as in Figure 7 2 12 XGT Settings PROFIBUS DP Master Module Position Base Number slot Number 0 d Cancel Figure7 2 11 Communication Settings Window for XGT Set to install Pnet I F module Chapter 7 Program Example Online Settings FOR PROFIBUS DP _ Connection settings General Timeout interval Retrial times Read rite data size in PLC run mode
69. eisanHuan Road DongCheng District Beijing 100013 P R China Tel 86 411 273 7777 86 411 8730 7560 e mail cuibx Isis com cn Tel 86 10 5825 6027 666 86 10 5825 6028 e mail xunmj Isis com cn m LSIS Guangzhou Office Guangzhou China Address Room 1403 14FL New Poly Tower 2 Zhongshan Liu Road Guangzhou P R China Tel 86 20 8328 6754 Fax 86 20 8326 6287 e mail chenxs Isis com cn LSIS constantly endeavors to improve its product so that 2013 11 information in this manual is subject to change without notice LSIS Co Ltd 2013 All Rights Reserved
70. evice Information item from Diagnostics then the contents below are displayed as shown in the figure below Device Information General Information Manufacturer 515 Manufactured Date 2013 09 25 Device Version WOOT O00 Device Number 00000004 Serial Mumber 00000001 Firmware Mame Firmware Type ABT Firmware Version 1 00 00 Firmware Date 2013 09 25 Configuration O ate 2013 09 30 18 42 Configuration Block Size 31 Configuration Done Configued Master Mode Communication Mode Endian Mode Big endian Figure 5 4 11 Master information Chapter 6 XG5000 Setting Chapter 6 XG5000 Setting In order to use Pnet I F module set High speed link parameters after PROFICON Configuration is uploaded and then download the specified parameters onto CPU for application which is available through the XG5000 6 1 XG5000 Setting Process To do each step of process refer to below description Setting too Network Configuration setting Refer to Chap 5 PROFICON setting PROFICON Communication Port connection Refer to Chap 5 PROFICON setting Parameter Network Configuration download Refer to Chap 5 PROFICON setting Execute XG5000 Execute XG5000 Project gt New project 5 Make New project Set project name Project type CPU type Basic XG5000 gt Online gt Select the driver Set 5000 Connection Setting in connection setting Connect XG5000 XG5000 gt Online gt Connection Onlin
71. fferent with already registered information the following message appears b Overwrite parameters of the PLC with modules installed in the PLC Detailed module parameters will be reset as the default if module type mismatch Continue Figure 6 2 9 IO change message window Chapter 6 XG5000 Setting 6 3 High speed Link parameter setting 6 3 1 Introduction of High speed Link XGT series provide 2 kinds of communication ways Those are P2P HS link HS link is used for a lot of data processing at once cyclically Pnet module provide HS link It can update output data or input data by using cycle set between main unit and Pnet master The parameter setting method is as shown below Download configuration data to Pnet module by using PROFICON 2 Upload configuration data in XG5000 3 Set Read Write device area in HS link block 4 Download parameter to main unit in XG5000 5 Enable HS link Data size can be set 1 244 bytes per station and communication cycle can be set from 20ms to 10s 1 Incase of Pnet HS link 1 block means 1 slave The blocks can be set by Max 64 and each block can use Max 244 bytes 2 HS link communication cycle means receiving and sending cycle between main unit and Pnet master module Communication cycle between master and slave module is set by bus parameter of PROFICON Chapter 6 XG5000 Setting 6 3 2 High speed Link Send Receive Data Processing For the application
72. ffice Tokyo Japan m LSIS Qingdao Office _ Qingdao China Address 16FL Higashi Kan Akasaka Twin Tower 17 22 Address YinHe Bldg 402 Room No 2P Shandong Road Akasaka Monato ku Tokyo 107 8470 Japan Qingdao City Shandong province 266071 China Tel 81 3 3582 9128 Fax 81 3 3582 2667 e mail jschuna lsis com Tel 86 532 8501 6068 Fax 86 532 8501 6057 e mail wangzy lsis com cn m LSIS ME FZE Dubai U A E m LSIS Europe B V Netherlands Address Jafza View Tower Lob 19 Room 205 Along Sheikh Zayed Address 1st Floor Tupolevlaan 48 1119NZ Schiphol Rijk The Netherlands Road Jebel Aali Free Zone Dubai United Arab Emirates Tel 31 0 20 654 1420 Fax 31 0 20 654 1429 e mail junshicko Ilsis com Tel 971 4 886 5360 Fax 971 4 886 5361 e mail jungyongl lsis com m Wuxi LSIS Co Ltd _ Wuxi China m LSIS Shanghai Office Shanghai China Address 102 A National High amp New Tech Industrial Development Area Address Room E G 12FL Hiamin Empire Plaza No 726 West Wuxi Jiangsu 214028 P R China Yan an Road Shanghai 200050 China e mail liyong Isis com cn Tel 86 510 8534 6666 Fax 86 510 8534 4078 e mail caidx lsis com cn Tel 86 21 5237 9977 609 Fax 89 21 5237 7189 m Dalian LSIS Co Ltd Dalian China m LSIS Beijing Office _ Beijing China Address No 15 Liaohexi 3 Road Economic and Technical Development zone Address B Tower 17FL Beijing Global Trade Center B D No 36 Dalian 116600 China East B
73. gh speed P2P And Link Enable window is displayed as shown below Select the applicable High speed link number and then select Write to set Chapter 7 Program Example EE 123 EE HIGHXEC EJ TIS High speed Link Ld ES High speed Link 01 B051 Internal FEnet DE High speed Link 02 Bet P2P EIP E P2P 01 8050 Internal Cnet E P2P 02 8051 Internal FEnet Figure 7 3 7 Link Enable High speed link P2P If you use others products to slave module Setting of using that products GSD file is same as above in order Chapter 8 Troubleshooting Chapter 8 Troubleshooting This chapter is to describe various errors that may occur in system operation their causes and actions to take against If any error occurs on Pnet I F module its related details can be checked through the procedures below Surely follow the troubleshooting procedures in the sequence as specified to check for abnormal module state And any discretionary repair or disassembly is not allowed 8 1 Symptoms and Management by LED Status It can know the simple symptoms by LED status and it can manage When High speed link is enabled XBL PMEC RUN VF High speed link Check the connection Abnormal connection of slave Sn P i e status of a slave Check the setting of slave Check the cable short Check the module with different speed On Off On Off Bus error Check the coe ation device value bigger than HAS SyCon PROFICON Chec
74. guration for Profibus DP Master module gt O Bus error Line short Link soeed unmatched and etc O Flickering Downloading or Uploading Configuration parameter to Master module Off Configuration is installed successfully Table 2 3 1 LED display of XBL PMEC Chapter 2 Specifications 2 4 Cable Specifications 2 4 1 Cable Specifications m Aluminum Foil le Polyester Tape Braid Shield 8500 pF ft UU VV Characteristic impedance 1500 EC XX Remark 1 Cable type 1 Tomas cable Profibus DP UNITRONIC BUS L2 FIP BUS 2 Belden cable 3079A Chapter 3 Installation and Test Operation Chapter 3 Installation and Test Operation 3 1 Installation Environment This product is very reliable regardless of installation environments but to guaranty the reliability and stability of the system pay attention to the following items 1 Environment Conditions 1 Install in the control board where waterproof and dustproof are possible 2 The places where constant impacts or vibrations are imposed 3 The places where direct rays are not directly exposed 4 The places where dew is not formed by the rapid change in temperature 5 The places where surrounding temperature is maintained to be at 0 55 C 2 Installation Constructions 1 Make sure wiring leavings are not inserted inside the PLC when you process screw holes or do wiring jobs 2 Install the places where it is ea
75. igure 5 4 1 Master debug mode Chapter 5 PROFICON Setting If any slave generates diagnostic information for cable cut off incorrect parameter or configuration then Diag event is displayed at the slave on the topology as shown in the Figure 5 4 2 to inform the user se PHOFICON LS PROFIBUS DP Master Configuration Tool Contig XGB File Edit View Configuration Communication Diagnostics Tools 127 ud 13 A c3 j Am UM Device list Ix Achill iuc a EJ Config lt XGB gt 4 L Topology selector Linear View Window Help 00 e GPL TR2A B C E GPL TR4A B C PROFIBUS DP NETWORK ANALYSIS SHEET DIAGNOSTICS MODE sl Project Config zd E Si Addr 000 XBL SEE PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION Addr 001 XG GPL AC8C Config 2013 04 23 20 33 07 001 000 000 GPL AV8C NO OF DEVICES LEGEND GPL DV4C 001 Master s 001 Slaves MASTER SLAVE m OWNER ACTIV DeACTIV A wDOG ON f DIAG EVENT GPL DC4C XGL PSRA XPL BSSA Slave 0 Valves T Slave 0 Controller m GSD Viewer 4x 1 Master properties 22124 LN SET General Information peo 9 0 0 1 XGL PSEA Slave 1 11 01 Out 04 General Information v Output window Detail Information DEVICE DIAGNOSTICS Periodic l Gener
76. ile Edit View Configuration Communication Diagnostics Tools Window Help aisi sw A a C Topology selector Linear View dH Ed Spe Device list E3 Config1 X Project explorer amp g GPL DCAC aji amp 9 GPL DV4C PROFIBUS DP TOPOLOGY DESIGN SHEET P PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION 5 ee ee D24 evision i Config 2013 09 27 18 43 55 001 000 000 Addr 001 GPL DT4A B C em GPL DIANBAC NO OF DEVICES LEGEND GPL TR2A B C 001 Master s 001 Slave s MASTER SLAVE OWNER ACTIV DeACTIV amp WDOG ON WDOG_ m n Slave properties Ax T gt gt 0 0 0 XBL PMEC Master0 General Information mE Model Name GPL DTAA B C 1 Station Slave nD Vendor LS Industrial Systems Co Ltd Pe Ident Number 0x07B3 A GSD File Name LGISO7B3 GSD 1 GSD Revision 2 m General Settings Assigned Master Addr 000 XBL PMEC Station Address 1 004 Description Slavel Activate Device Activate 4 m Watchdog Control Enable Output window a gt Dots Settings Cfg Master device XBL PMEC is added on the network Configi with address 0 Default ad Cfg Slave device GPL DTAA B C is added on the network Config1 Bus Parameter Af Master Properties Slave Pro Figure 5 2 5 Compose slave to master perties CAP NUM SCRL S I
77. ink trouble 0 Individual HS link information Index Master Station No Station number Module type Transmission Transmission Consistency Over Reception Reception Consistency Over 0 0 1 Output Type 2Byte ByteOrWord 1 0 2 Input type Byte ByteOrWord _ cece Figure 6 5 3 High Speed Link Chapter 6 XG5000 Setting Displays the base no 0 Displays the slot no 1 10 ee Displays the communication speed by bps unit speed 9 600 bps 12Mbps Displays the master station no 0 123 Total Displays the flag of Run Link information of high speed Link trouble Displays the flag of Link Trouble link ByteOrWord Consistency supports for a node Transmission Whole Length Consistency supports for whole Consistency Over blocks Slave module gt Master module ByteOrWord Consistency supports for a node Reception Whole Length Consistency supports for whole Consistency Over blocks separate Displays the size of Transmission Reception byte information Displays the mode of Profibus DP communication mode Run Stop of high speed Mode link n E Displays the information of Transmission Reception ransmission between master and slave Normal Error or Reception Status of high Displays the information of high speed link between master and speed link slave Normal Error m the error information between master and slave Normal Error There are 2cases of e
78. ject name in the XG5000 software EBEN File location Selecting the directory to save the project BEEN PLOSeies Writing the comment about the project BEEN Table 6 2 1 Contents of new project Chapter 6 XG5000 Setting After setting CPU t amp PROFIBUS XGS000 e new project screen of XG5000 is shown as below Edt Find Replace View Montor Debug Tools Window Help Da Gu BS 9 EAE l gt OA aunznaxmovywuwvw OndaggduGub a D Daa s B Esc FS 1 oF FS Fass FS Fi se 575 c5 ci TE PROHBUS 4 4 Network Configuration Unspecified Network NewPLC 18050 Internal Cnet System Variable 4 NewPtCiXGB XBC Offline Variable Comment d Pararneter Basic Parameter Id vo Parameter Internal Parameter a By Scan Program 3 NewProgram Hewtt Figure 6 2 3 New project screen of XG5000 6 2 2 Registration of the communication module For the basic setting of the communication module in the XG5000 you window You can register the communication in the both ON OFF status 1 Registration in the offline status If you want to register the communication without connection select applicable base and press the right button of the Unspecified Network And then select Communication on the Add Item Select the Pnet
79. k 001 5 MeuPLC BIT L888181 0n HS1 H0DBO1 Operation mode of HS link 1 block 001 6 NewPL BIT 1800102 _ 1_ 00902 Operation mode of HS link 1 block 902 NewPLC BIT 1000480 On HS1 TRXBBB Normal communication with HS link 1 block 000 NewPLC 1000181 On HS1 001 Normal communication with HS link 1 block 661 9 NewPLC 1000260 Off HS1 ERR8BB Error mode of HS link 1 block BBB 18 NewPLC L880261 OFF HS1 ERRBB1 Error mode of HS link 1 block BB1 EM Monitor 1 E Z E 5 5 a m m Figure 6 4 1 Monitor window of variables Chapter 6 XG5000 Setting 1 Run link HSxRLINK As the whole information it shows whether High speed link is normally executed through the user defined parameters whose contact will be kept On if once On until Link Enable is Off and also will be On under the conditions specified below D If Link Enable is On 2 If all the register list settings of parameters are specified normally 3 If all the data applicable to the parameters register list is transmitted and received as specified in the period or If the status of all the destination stations specified in the parameters is Run and with no error at the same time 2 Link trouble HSxLTRBL link No 1 2 As the whole information it shows whether High speed link is normally executed through the user defined parameters which will be On if Run
80. k the connection of Off Flicke setting changes during slave r High Speed Link Check the setting of operation slave ENS por foe dee reme 1 HAS Highest Station Address Table8 1 1 Symptoms related communication module When High speed link is enabled 8 2 System Diagnosis of PROFICON System Diagnosis of PROFICON refers to 5 4 Diagnosis function 8 3 System Diagnosis of XG5000 oystem Diagnosis of XG5000 refers to 6 5 Monitor of High speed link information Chapter 8 Troubleshooting 8 4 Diagnosis of Communication Module by using XG5000 XG5000 connection program can be used to monitor the communication module simply Connect with CPU port and then select On Line gt PLC History gt PLC Error Warning in XG5000 Code ate Time Contents 1384 01 01 00 00 00 000 Module detach error Base 0 Slot 1 1884 01 01 00 00 00 000 Module detach error Base 0 Slot 1 1884 01 01 00 00 00 000 Module detach error Base 0 Slot 1 1884 01 01 00 00 00 000 Module detach error Base 0 Slot 2 1884 01 01 00 00 00 000 Module detach error Base 0 Slot 1 1984 01 01 00 00 00 000 Special Cammunicatian module interface ern 1984 01 01 00 00 00 000 Module detach error Base 0 Slot 1 Details Remedy Check if the module is installed correctly and reset the PLC and then try again Fig 8 4 1 PLC history details monitor Chapter 8 Troubleshooting 8 5 Troubleshooting 8 5 1 Conn
81. l be a data transmission cycle between CPU module of PLC and Master communication module In emergency output setting is set suitable to user s environment Click OK and then Block is created below High speed link 1 Double click it After block is created click the index of block information frame right frame Click Online Config Upload Dnet Pnet and it brought the setting information in PROFICON _ 7 Online Monitor Debug Tools Window Help Disconnect Ex Li B B gao qn Kr Connection Settings Ru ae p m r A UA icin Safety Signature li x HIGHXEC Xx Change Mode t Stati a number Write ee an Compare with PLC E y Set Flash Memory E S L I Control Redundancy J Communication module setting Enable Link HS Link P2P H Reset tle Vu E Upload DownloadlFile Diagnosis HM S R a sd Tag Manager Force VO Skip 1 0 Fault Mask Module Changing Wizard Base Changing Wizard I M Ef Start Online Editing Ctrl Q Eb Write Modified Program Ctr W End Online Editing Figure 7 3 4
82. le Data Settings Parameter Data Default Bus Parameter Hf Master Properties 8 Slave Properties M SCRL LS Industrial Systems Figure 7 2 5 Change Slave Properties If station number and description properties are changed the changed number and properties are immediately reflected on the project window as seen in the figure below File Edit View Configuration Communication Diagnostics Tools Window Help E ES md eB OCT d Topology selector Linear View Device list ax p Config1 X Project explorer Slave 1 Switching Device LA 824 PROFIBUS DP TOPOLOGY DESIGN SHEET SUN project Corfigr 0201310010 Slave 24 1 0 2 4 Addr 000 XBL PMEC 1734 amp g T1H PBC amp g GPL D22A amp g GPL D24A amp g GPL DT4A GPL RY2A amp g GPL TR2A amp g GPL TR4A GPL AC8C GPL AV8C amp g GPL DCAC PROJECT NAME DATE Revision VERSION DESCRIPTION Configl 2013 10 01 03 40 24 001 000 000 NO OF DEVICES LEGEND 001 Master s 001 Slave s MASTER SLAVE OWNER DeACTIV A WDOG ON WDOG OFF iAy Addr 004 GPL TR2A B C uml 000 1 1 jJ D GSD Viewer 68 2 S Slave properties vax 218415 General Information Model Name GPL TR2A B C Ident Number 0x07B4 Station Type Vendor Name LS Industrial Syst GSD Revision 2 Ident Number 0 0
83. ll communication modules and register them automatically cC XG5000 oe ee ee Window Help Deal ag amp Disconnect iw 5 ooo a S Connection Settings R 4 Fd F INE PES F3 F4 SFI sf FS F6 578 f Project 4 123 5 Network Configuration 4 9 Unspecified Network gj NewPLC BOSO XGL C gj NewPLC 8055 XGL E gt B 1445 8050 LYS gt gy D45 XEC 8051 LUZ gt 31448 XEC 8052 XBL gt DASXEC 8053 XBL ba E System Variable gj NewPLC XGI CPUH Canna 3445 XEC XGB XECU Sto p Global Direct Variables ie Parameter Bl Basic Parameter 9 Parameter View High speed Link Safety Lock Safety Signature Change Mode Read write amp Compare with PLC Set Flash Memory Control Redundancy Reset Clear Diagnosis Force Skip I O Fault Mask View 2 Base Changing Wizard Function FB o Start Online Editing MostRecentlyUsed Write Modified Program ox End Online Editing Function Name Monitor 1 Communication module setting Module Changing Wizard Progam Variable Device R L 1 An gg v amp ode EX F3 FS FS FS FS Gh PLC Information 07 PLC History PLC Errors Warnings Save PLC History 03 euopJ 60 eje3 ion Ctri Q Ctri W Ctrl U v l x Result
84. ly installed The type name of A and B ask to cable maker 2 AWG American Wire Gauge Number system of size a diameter of wire Chapter 3 Installation and Test Operation 1 General safety instruction If distance between stations it can be extended through extension of segment Maximum 9 repeater 10 segment It can be connected 32 stations repeater included per segment and maximum 126 stations can be connected Repeater has no number of station There are extension segment that has no station Shield of cable is grounded to housing of connector It has to use exclusive connector which is inductor built in in internal It can not use the Spur Line If the gap between stations is large a large current is able to flow on a shield In this case Install the cable which is set the a potential difference of ground Special attention is required more than 1 5Mbps It maintains minimum distance more than 1m between station at 12Mbps 2 Termination 1 Each segment has to terminate the end If segment is many every segment have to terminate the end 2 Termination is able to On Off by switch of exclusive connetor Remark 1 Maximum number of repeaters is different from each repeater module Chapter 3 Installation and Test Operation 3 4 From Setting to Operation The sequence of the product from installation to operation will be described below After the product installation is complete install and configure the
85. matically as seen in Figure 7 2 16 Chapter 7 Program Example 22 PROFICON LS PROFIBUS DP Master Configuration Tool Configi 5 _ File Edit View Configuration Communication Diagnostics Tools Window Help 5 G d BM E bd 53 3 C Topology selector Linear View eA A dj cj Au Device list vw ix Config1 Project explorer 4x amp g 8 amp g GPL Dv4c PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION ciii Project Config 2013 04 29 20 49 35 PROJECT NAME DATE Revision VERSION DESCRIPTION 5 Addr 000 XBL PMEA XGL PSRA evision d E Config 2013 04 29 20 43 35 001 000 000 T Addr 004 GPL TR2A B C XPL BSSA OF DEVICES LEGEND slave 0 Valve 001 Master s 003 Slave s MASTER SLAVE OWNER DeACTIV WDOG ON WDOG_O alt hes d Nom i EXE 004 10 00 amp 9 XGL PSEA T amp BIS S 60 2 r 4003 GPL D22A C Slave3 ETT pms properties GSD Revision a 3 n XPL BSSA Slave6 10 03 04604 General Settings Assigned Master Addr 000 XBL PME Vendor Name LS Industrial Systi Station Address 6 Ident Number Ox09F7 Description Slave6 GSD File Name XPLBSSA GSD Activate Device Activate GSD Revision 1 Watchdog Control Enable Detail Information Data Settings Parameter Data Default Module Data Checked Output window De
86. nd 3 slaves are alive 10 2 3 4 5 8 g 0 1 2 3 4 5 8 g 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 022 023 024 025 026 O27 028 029 030 O31 032 033 034 035 036 037 038 042 043 044 045 046 O47 048 049 050 O51 052 053 O54 055 056 057 058 062 063 O64 065 066 067 068 069 070 071 072 073 074 075 076 077 078 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 1223 123 124 125 126 Master Slave Num DupSlv Nema Dup Mod Undefined GSD Detected Slave IDs Detected Module IDs Modules Max Select Model Name GSD File Name Module ID Module Name Inputs Outputs Module Slave Ox07b1 GPL D22A C LGISO7B1 GSD 0x00 0x11 Fixed 0x00 0x11 D Byte Out 2 Byte In Fixed 0x00 0x11 D Byte Out 2 Byteln 2 BYTE Fixed 004 Ox07b4 GPL TR2A B C LGISO7B4 GSD 0521 0500 Ton Fixed 0x21 0x00 2 Byte Out 0 Byte In 2BYTE Fixed 0x21 0x00 2 Byte Qut 0 Byte In Fixed 006 Ox09f XPL BSSA PLBSSA GSD 021 013 0213 0x23 0 23 0x20 6 8 Fixed Ox21 Digital Output 2byte 2BYTE Fixed 0x13 Digital Input 4byte 4 BYTE Fixed 0x13 Digital Input 4byte 4 BYTE Fixed 0x23 Digital Output 4byte 4BYTE Fixed 0x23 Digital Output 4byte 4 BYTE Fixed 0x20 Digital Output 1byte 1 BYTE Fixed Figure 7 2 15 Results of Automatic Network Scan At this time pressing the OK button will prompt setting network topology auto
87. ndustrial Systen Chapter 5 PROFICON Setting Basically the tool allocates the station address in sequence when composing each device to the topology Therefore if you want to change the station address and property of the slave then use Slave Properties of Configuration menu to change it Followings are the items to be available for setting by using slave property tab See Figure 5 2 6 Station Address 1 123 Description texts Activate Device Communication watchdog User s parameter settings Module settings User s parameter and module are configured by using separate window Slave properties todel Mame TIU d Station Type ee Vendor Name Ident Number ICI Ci GSD File Name GSD Revision General Settings Assigned Master Station Address Description Activate Device Watchdog Control Data Settings Parameter Data Slave lel n tT LS Industrial Systems Co Ltd Addr 000 XBL PMEC 1 Slavel Activate Enable Default AR Bus Parameter Sf Master Properties Sf Slave Properties M SCRL Figure 5 2 6 slave property tab Chapter 5 PROFICON Setting First of all the parameter is configured by using slave parameter settings window as shown below Slave Parameter Settin Current Slave Device Slave Name Assigned Master Name OK Add 001 GPL
88. nger may be expected Be careful Electric shock may occur The user s manual even after read shall be kept available and accessible to any user of the product Safety Instructions Safety Instructions for design process 1 Please install a protection circuit on the exterior of PLC so that the whole system may operate safely regardless of failures from external power or PLC Any abnormal output or operation from PLC may cause serious problems to safety in whole system 1 Install protection units on the exterior of PLC like an interlock circuit that deals with opposite operations such as emergency stop protection circuit and forward reverse rotation or install an interlock circuit that deals with high low limit under its position controls 2 If any system error watch dog timer error module installation error etc is detected during CPU operation in PLC all output signals are designed to be turned off and stopped for safety However there are cases when output signals remain active due to device failures Relay and TR which cant be detected Thus you are recommended to install an addition circuit to monitor the output status for those critical outputs which may cause significant problems 2 Never overload more than rated current of output module nor allow to have a short circuit Over current for a long period time may cause a fire 3 Never let the external power of the output circuit to be on earlier than PLC power
89. o slave module Receiving Transmit the data from slave module to master module Read area XBM XBC Area to set the start address of device used for Sending Master module Setting device U L D R ZR Area to set the start address of device used for Sending Slave module Setting device A M 1 W K L U Save area Area to set the start address of device used for Receiving Slave module Setting device P M K U L D R ZR Area to set the start address of device used for Receiving Master module Setting device A W K L U Send data Receive data Byte Display input output points of slave module by the bytes In case of I O module of 8 bits or less please set 1 byte 1 Area is not able to set Table 6 3 2 High speed link block Setting Chapter 6 XG5000 Setting 4 Write the High speed link parameter Click Online gt Write Parameters in XG5000 check the applicable High speed link and then click OK Sets Program Upload Prohibit Sets link enable with parameters HIGHXEC G PLC Configuration TILS Parameter Program Network Parameter Standard settings i Cnet based slot FEnet baseQ sloti NA Pnet Slave 51012 E High speed Link Taf High speed Link Q1 Internal Bl High speed Link 02 iE High speed Link 03 P2P 01 Internal 02 Internal Fig
90. oise Radiation electromagnetic IEC 61131 2 Fast Power Digital Analog I O Transient Class nodule communication interface IEC 61131 2 burst IEC 61000 4 4 Ambient Operating height 11 Cooling type Natural air cooling _ _ _ Table 2 1 General Specifications 1 IEC International Electrotechnical Commission An international nongovernmental organization which promotes internationally cooperated standardization in electric electronic fields publishes international standards and manages applicable estimation system related with 2 Pollution level An index indicating pollution level of the operating environment which decides insulation performance of the devices For instance Pollution level 2 indicates the state generally that only non conductive pollution occurs However this state contains temporary conduction due to dew produced Chapter 2 Specifications 2 2 Performance Specifications Performance specifications of Pnet I F module are as described below Item Details Master Profibus DP EN50170 DIN19245 RS 485 Electric Module Type Network Type Standard Interface Transmission Route Bus type NRZ Non Return to Zero Token Passing Modulation Type lt gt Distance 1 200 Transmission Speed bps 9 6k 19 2k 93 7k 187 5k 500k 1 5M 3M 6M 12M Max Distance amp Transmission Speed O O O O 100 Max number of stations per O wae num
91. on uploaded from current master _ E3 Contig XGB Config 1 PROFIBUS DP TOPOLOGY DESIGN SHEET CONFIGURATION MODE PROJECT NAME DATE Revision VERSIUN AUTHOR DESCRIPTION Contig 2013704229 20 20 30 001 000 000 NO OF DEVICES LEGEND 001 Master s 001 Slave s MasteR BSLAVE OWNER ACTIV DeACTIV wDOG ON A WDOG_OFF Eg Li 001 5 OO M fil Mastert 1 VIRI ROT Slavet PROFICON PA Output window ee ee Uploading binary image Checking master firmware version Ver 1 04 00 Done starting binar Mee reception one percent have been received one NUM Figure 5 3 6 Uploading completed Chapter 5 PROFICON Setting 5 4 Diagnosis function Applied functions of PROFIBUS DP include network diagnosis function and monitoring function Please see software manual for details 5 4 1 Start Stop Communication Start Communication and Stop Communication item of Diagnostics starts or finishes the PROFIBUS DP communication by setting up master mode as OPERATE or STOP mode 5 4 2 Debug mode Start Stop Debug Mode Device Diagnostics 1 Start Debug Mode The Start Debug Mode of Diagnostics menu continuously monitors the status of slave in debug mode At this time the topology is activated and regularly checks out the status information of slaves from master
92. parameter is unstable The link trouble will be On if one of those conditions 1 2 and 3 above occurs And if such a condition is back to normal it will be Off Displays the general status of the communication information for the specified parameter s respective data blocks HS1STATE k 2HS1MOD k amp HS1TRX k amp HSmERR k Displays the operation mode of the station specified in parameter s data block k Displays the communication status of parame ters data block k to check if normal as specified Displays the communication status of parame ter s data block k to check for any error Displays the setting status of parameter s data block k Appendix Compared with HS link of 1 in Table 1 other HS link station number s LOOO00 LXO L flag address will be simply calculated as follows LOO21F X351 Calculation formula type L00000 260 x HS link No 1 LOO260 LX416 IEC type 9eLXO 416 x HS link No 1 LOO45F JL X 6 Appendix A 3 PROFICON Error code When the error codes exist in the output window After Check your communication data message was shown The meaning of this error code is as below Function Errortype Code WN_AREA DCOMMAND download ERROR _ WT If it is different between command type and Image NOTALLOWEDA Hae MM ECCESSO download E ERROR INVALI If block ID which want to download is different from block D BLOCKNO 10 1 ERROR_INVA
93. ped from PCB of the connector 3 The number of stations to be installed shall be within 32 including master and repeater for 1 segment 4 The shielded line of the cable shall be in contact with the shielded area of the connector 5 The cable is generally recommended to be installed at the end of the slave diverged from the master 6 Ifthe cable is used at the object car use the extended line 7 Communication cable shall be installed at least 10cm away from the power supply cable 8 Check the cable connected with the connector if tightened well with terminal block 9 After the cable connected measure the line resistance value on the master by means of digital multi meter If terminal resistance at the both ends of the cable is On it will be generally 1100 line resistance value connector resistance value Chapter 3 Installation and Test Operation 3 6 Test Operation Terminal resistance switch of Pnet cable shall be On If the switch is not On communication errors may occur Check LED operation status if normal with power on after communication cable is connected If normal download the applicable program to PLC via XG5000 so to execute the program 3 6 1 Precautions for system configuration 1 Station No of each slave shall be surely different from each other including this module If connected with the repeated station No communication error may occur leading to communication trouble High speed link station
94. rameters are contained No Send Receive Operation High speed Link t Whole Whole Individual Individual Individual Individual Information type information information information information information information Keyword name x High speed link No HSxTRX n HSxMODf n _ HSxSTATE n n High speed link HSxETRBE 8 063 n 0 63 0 n 0 63 station No Datatype type Datatype Bt Bit BitArray BitAray Bit Array Bit Array Available Available Available Available Available Available Available Available Available Available Available Available Table 6 4 1 High speed link information function The user can use the information in keyword format when programming and also monitor the High speed link status using the monitor function of the High speed link information Prior to its application the user is requested to check the reliability of the Send Receive data through High speed link information of Run link and Link trouble when operating several PLCs with High speed link used Table 6 4 1 below shows functions and definition of the High speed link information 1 NewPLC L888888 007 On HS1 RLIHK All stations are OK in HS link 1 2 MewPLC L8880BB1 Off HS1 LTRBL Trouble after HS 1 RLIK on NeuPLC L8888280 jj 0n HS1 STRTEBBB Total states of HS link 1 block 666 NewPLC BIT L888021 5j On 51 STRTEBBi Total states of HS link 1 bloc
95. rge toxic materials or explode itself Revision History Version Date Remark Page 1 0 13 11 First Edition V1 1 15 03 XG5000 V4 0 UI Updated Entire The number of User s manual is indicated right part of the back cover LSIS Co Ltd 2013 All Rights Reserved About User s Manual 5550050550500 _ Congratulations on purchasing PLC of LSIS Co Ltd Before use make sure to carefully read and understand the User s Manual about the functions performances installation and programming of the product you purchased in order for correct use and importantly let the end user and maintenance administrator to be provided with the User s Manual The User s Manual describes the product If necessary you may refer to the following description and order accordingly In addition you may connect our website http www lsis com and download the information as a PDF file Helevant User s Manuals Description XG5000 software user manual describing online function such as XG5000 User s Manual programming print monitoring debugging by using XGK XGB CPU XG5000 software user manual describing online function such as programming print monitoring debugging by using XGI Pun CPU XG5000 User s Manual for XGI XGR User s Manual instructions that are used PLC system with XGK XGB CPU XGI XGR Instructions amp Programming Users manual for programming to explain how to use XGK CPUA CPUE CPUH CPUS CPUU user manual describing X
96. rrors as below a In case that slaves doesn t exist on the network after slaves is configured in PROFICON b In case that slaves exist on the network after slaves is not configured in PROFICON Table 6 5 3 High Speed Link Chapter 6 XG5000 Setting 4 Autoscan Autoscan Standard information Additional information Status information Base Number Master st 0 Module Status OPERATE Slot Number Speed 1 5 Mbps HS link status HS IDLE 4 5 7 GPL TR2AJB C GPL D224 C XPL BSSA Multiple Reading Refresh Figure 6 5 4 Autoscan Basic Displays the base no 0 information Es the slot no 1 10 depending main unit Masterstaionno station no Displays the master station no 0 123 the master station no 0 123 Added information Communication speed a MEE ut speed by bps unit Status Status of communication module Displays the status of communication module the status of communication module information Status of high speed link Displays the status of high speed link Table 6 5 4 Autoscan Chapter 7 Program Example Chapter 7 Program Example 7 1 Example of communication with XBL PMEC This example shows a program that is installed on No 0 slot of XGT No 0 base sending and receiving data to Smart module Station Number 3 and 4 and Extended Smart Pnet Station 6 XBL PMEC Station 11 METER P cuan irs o Fr GPL TR2A GPL D22A APL BS
97. s Select PHO ID Model GSD File Name Module ID Module Mame Inputs Outputs Module Slave 0521 0500 2 Byte Out O Byte In 2BYTE Fixed 0x21 0x00 2 Bute Out 0 Byte In Fined 057 Uxffff E GPL D224 GPL D223 amp G5D 0x21 0 00 Discard GPL D244 GPL D244 amp 35D w21 D Discard GPL DT 44 GPL DT4 amp G5D 0x21 0500 Discard GFPL A Y 2A GPL_AY24 GSD 021 0 00 057 0x21 000 2 Bute Out Byte In Fined 0521 Ox00 2 Byte Out O Byte In Fixed I3PL TR24 GPL TR2 amp G5D 021 0 00 Ei 057 0x21 0x00 2 Bute Out 0 Byte In Fined 0521 0x00 2 Bute Out 0 Byte In Fined GFL TA 4A GPL_TR44 G5D 021 0500 Discard 058 XPL B55A XPLBSSA 35D x21 Ox20 0510 Fixed 0521 Digital Output Fined 5 19 Chapter 5 PROFICON Setting 5 4 5 I O Data Monitoring This is the function to monitor I O data of slaves This can confirm whether the of a certain slave is correct If I O Monitor item is selected from Diagnostics then existing data communication is stopped and the monitor window pops up as below If users enter the output into the output data and click update button then the value will be displayed through slave And then the values entered through current slave will be monitored through the input data area Here the number of data available for I O is 32 bytes respectively Monitor Input Data OK HEX oo m o2 os o o o O9
98. saving auto scanned contents as a binary b If there are more than two slaves that have same PNO ID compared with loaded slaves select button will be shown If the slaves don t have same module ID or the slave is compact slave that have to be defined more than one Discard will be shown and Select button will not be shown If there are slaves that don t have same ID compared with loaded slaves at the same time modular type which don t need module Discard will not be shown and Select button will be shown It s because PROFICON judges that the user intends for adding module through Configuration Compact slave If Modular_Station 0 is shown in the GSD file or there is no Modular_Station key the module have to be defined more than one Modular slave If Modular_Station 1 is shown in the GSD file c In case that there are more than two selectable slaves the Select button is checked So If you want to change slave change the checking status and select the slave that you want Network Scan Detected Devices master s and 64 slave s are alive 0 Add oe eta DR epus o 000 001 002 003 014 015 015 20 020 021 022 023 034 035 035 40 040 041 042 043 054 055 056 6 060 061 062 063 074 075 076 80 080 081 082 083 094 095 096 100 100 101 102 103 114 115 116 120 120 121 122 123 Legend Masher Undefined GSD Detected Slave s Module Information Add Detected Slave IDs Detected Module IDs Module
99. standardized GSD file e PROFICON has diagnostic function e PROFICON has a function to upload network settings which was previously downloaded Chapter 5 PROFICON Setting 5 1 3 Screen composition T Elysion LS PROFIBUS DP Master Conagurason Too ETT T Project Project explorer File Edit View Configuration Communication Diagnostics Tools Window P UP UP T aS um gm ud Topolog mim aaaaaaaaaado RR EP contia zu n topology rect Bc N b Li gt I au PUED o PROFIBUS DP TOPOLOGY DESIG CONFIGURATION MODI Project Config Pnet COM C DPM PROJECT NAME DATE Revision VERSION AUTHOR DESCRIPTION Contig ZDOBRAT 20 53 44 On 000 000 OF DEVICLS pee Masters 000 5 Mi MASTER OWNER ACTIV DeACTIV WDOG ON wDoOdG OFF a SV4S Series Slave 2 0 List of devices l GPL DT4A a GPL AY2A 11 GPL DO4A C Master slave Z General Information property window A Date Settings Parameter Dat Module Data Detail Information Output window J f Bus Mas F Slav oe a ir il mm Figure 5 1 1 PROFICON screen composition Device list Lists the devices interpreted by GSD file to drag amp drop them to topology of proje
100. sy to control 3 Do not install into the same panel as high press machine 4 Make sure the distance to the duct and the surrounding module is maintained to be more than 50mm 5b Put to earth where surrounding noise environment is good Over 100mm Over 50mm Over 50mm Chapter 3 Installation and Test Operation 3 2 Cautions when Handling Observe the following directions when you configure the system using Pnet I F module 1 Do not drop or impose strong impact 2 Do not separate PCB from the case It may cause malfunctions 3 Make sure foreign objects are not put into the upper area of the module while you do wiring jobs 4 If foreign objects are entered remove them 5 Do not remove the module when light is On 6 Use standard cables and install within maximum distance 7 Make sure communication lines are not affected by surges and inductive noises that may occur from alternating current or current parts 8 In case the machinery or the substances that may generate high temperature are nearby you or when wires directly come into contact oil and other things for a long time when you do wiring jobs it may cause a short cut damage or malfunctions 9 When you do wirings during pipe arrangement it is necessary to put to earth to pipes Chapter 3 Installation and Test Operation 3 3 Precautions for Installation During the system configuration using Pnet F module please check the detail conten
101. tail Information Cfg Master device XBL PMEA is added on the network Config1 with address Cfg Slave device GPL TR2A B C is added on the network Config with address 1 Station Address Cfg Slave device GPL D22A C is added on the network Config1 with address 1 Moe T Cfg Slave device XPL BSSA is added on the network Config with address 1 Do pe optem GSD Viewer General Information Model Name XPL BSSA Station Type Slave 2 53 E meee Bus Master Pr Slave Pro CAP NUM SCRL LS Industrial Systems Figure 7 2 16 Screen that has been set through Automatic Network Scan To change Slave Properties click a module from the topology and change them through the Slave Properties Window on the left bottom 7 10 Chapter 7 Program Example 7 3 XG5000 settings This part describes how to assign the internal memory by XG5000 Click File gt New File and select project name and PLC series in the New Project window New Project v Auto allocation Figure 7 3 1 New project Select the Online to connect with CPU and Online menu Read IO information is brought information of each slot installed H Li ES Fa IN OT i Prud new Onie Manor Debug Window Dal am
102. ter 5 PROFICON Setting Online Settings FOR PROF Connection settings gt Depth Local General Timeout interval Retrial times Head gt Write data size in PLC run made Normal 9 Maximum Send maximum data size in stop mode Figure 5 3 2 Connection setting 1 Once the communication settings have done when you execute image download upload diagnostic function it will communicate with recent setting values case that communication setting is changed set communication again and then execute image download upload diagnostic function Chapter 5 PROFICON Setting 2 Network Configuration download If you already composed network in the topology select Download Image item from the Communication menu to begin downloading The figure below shows downloading status The status bar runs progress bar and the output window shows the progress rate _ E Configi In 01 Out01 2 4 Output window Ix Downloading binary image Checking master firmware version Ver 1 00 00 Done Erasing master memory space 16 percent have been completed m Figure 5 3 3 Download status If downloading is completed the progress bar is full and Done message will be displayed on the output window E EJ Config XGB PROFIBUS DP TOPOLOGY DESIGN SHEET
103. tered items High speed link status just like the max register number which synthesizes the information of the individual items to display the general information of the registered items In other words if the applicable lists Send Receive status is normal with the operation mode of Run and with no error it will be On and if the conditions above are violated it will be Off Chapter 6 XG5000 Setting 6 5 Monitor of High speed link information High speed link information can be checked through the variable monitor on the monitor menu after XG5000 is Online connected or through the XG5000 diagnosis service 1 High speed link monitor from the XG5000 diagnosis services 1 Select XG5000 s Online gt Communication module setting System Diagnosis gt Click the right mouse button with the cursor positioned on the applicable module e ua accom fee Project Edit Find Replace View Online Monitor Debug Tools Window 8 ae ons slile CY A 45 R P N 1 P Vy je Ww Esc F3 F4 sF1 sF2 F5 s sF9 F9 F11 sF3 sF4 sF5 sF6 F10 sF7 c3 c4 2 8B 123 5 Network Configuration a Unspecified Network b A HIGHXEC BOSO LHZ Cnet XBL PSEA NBL PHEC gt og HIGHXEC 8051 FEnet gt E HIGHXEC BOS2 XBL PSEA 4 8053 XBL PMEC 1 High speed Link 03 NewPLC BOSO XGL CH2A i xy NewPLC 055 XGL EFMT EC System Variable 4j NewPLC
104. tes Block 1 data size 8 BIOCK 2 data size 8 Block pack2ena data size 8 packN number of bytes Block packn 1 1 data size 8 Block packn 1 2 data size 8 packNeng data size 8 Number 8 means the size of block information in here b Calculate all of HS links transmission time HS link cycle have to be set bigger than whole HS link transmission time At this time if calculated transmission time of each pack is smaller than 10ms transmission time of applicable pack have to be calculated as 10ms All of HS links Transmission time Transmission time pack2 Transmission time packN Transmission time pack1 Transmission time pack1 number of bytes 25 US main unit scan time communication module scan and margin 5 ms pack2 Transmission time pack2 number of bytes 25 US main unit scan time communication module scan and margin 5 ms packN Transmission time packN number of bytes 25 US main unit scan time communication module scan and margin 5 ms c The number of blocks which can be set per HS link cycle As shown below table in case that the scan time of main unit is within 2ms and only one communication module is equipped the number of blocks which can be used for HS link cycle service Data size of eee each block Stations Babe 1 20m be 2 _ sm bye 5 _ toons _ mom
105. ts as below 1 Check the necessary basic elements to configure the system and then select the appropriate communication module 2 Select dedicated cable of Pnet to use for Pnet communication module 3 Make sure whether connectors are damaged or not when you connect between connector and module 4 All of communication modules can be equipped with max 2ea regardless of module type The below table describes how many expansion module can be attached depending on the type of main unit Classification High E High Standard Modular Performance Performance number 5 After attaching the module to main unit lock the module up and then connect the communication cable 3 3 1 Installation of cable Shielded Twisted Pair Cable is used as Profibus cable The maximum transmission distance by specification speed and type of cable is as shown below Table 3 3 1 and Table 3 3 2 m 135 1600 freq 3 20MHz 100 1300 freq gt 100kHz Capacit Lower than 30 pF m Lower than 60 pF m Resistance Lower than 110 Conductor Area Larger than 0 34 22 AWG Lager than 0 22 mm 24 AWG Table 3 3 1 Specification of cable B 192 93 75 187 5 1500 3000 6000 12000 Cable B 1200m 1200m 1200m 600m 200m 70m Table 3 3 2 Trasmission distance by Cable and Speed Remark 1 It defines two type of bus cable in Profibus standards But it is usually recommended Type A which place is new
106. twork XBL PMEC provides communication speed as scan below 9 6 k 19 2 k 93 75 k 187 5 k 500 k 1 5 M 3M 6M 12 M LIVELIST NOTREADY If reading slave list is asked in PROFICON before MISC NOTSUPPORTED _ BAUDRATE being finished of autoscan Request execution LIVELIST PARAM ERRO result of R LIVELIST COLLISION networ ROR If the master station is bigger than 123 or the error of Initialization of parameter is happened when reading the result of autoscan If the master station number is same with slave station number 4 ERROR SLAVE ADDR If the slave station number is bigger than 123 CON NA If reading information is asked before completing autoscan data It is demanded to wait for certain time to get the result of auto network scan after auto network scan is asked Waiting time refer to 5 4 4 auto network scan Appendix Imensions A 4 External D Unit mm e XBL PMEC XBL PMEC SOLO3NNOO NOISNY dX3 MADE IN KOREA 5500 J 00000 Warranty and Environmental Policy 1 Terms of warranty LSIS provides an 18 month warranty starting from the date of production 2 Range of warranty For problems within the terms of the warranty LSIS will replace the entire PLC or repair the defective parts free of charge except for the following cases 1 Problems caused by improper conditions environment or treatment 2 Problems caused by external devices 3 Problems
107. u use Pnet configuration software tool you can configure the slave modules in the network automatically AGT ABL PMEC XG5000 v PROFICON Configuration o e r 7 80 K120S GPL DT4AV A1 BIC C1 G7L PBEA GPL TRAAIAT BACIC1 0 IR Repeater Sma Smart l O PROFIBUS GPL TR2A A1 C1 CP D2 SAIC GPL RY2AJC GPL TR2B C GPL D24A C Figure 4 1 XBL PMEC Composite system Diagram Chapter 5 PROFICON Setting Chapter 5 PROFICON Setting 5 1 1 Main functions Category Function Desoripton _ Master property Master property group settings olave property slave property module and parameter settings communication bus parameter settings Configuration down Network Configuration download Configuration upload Network Configuration upload otart Stop Communication otart Stop Profibus DP Communication Start Stop Debug Mode Slave s status is continually read and shown Device Diagnostics on the topology design sheet Showing normally communicating devices Diagnostic Automatically scanning all of devices connected I O Monitoring Read Write data from slaves Disconnection Report Showing the number of disconnections Device information Information of master 5 1 2 Characteristics Configuration e is a configuration tool of Pnet module which is global standard PROFIBUS DP Master e PROFICON configures with
108. ure 6 3 5 Screen of Write the parameter Chapter 6 XG5000 Setting 5 Enable of High speed link Click Online gt Communication module setting gt Enable Link in XG5000 check the applicable High speed link and then click Write If High speed link is enabled on the module s LED display High speed LED will be On when High speed link starts Enable Link HS Link P2P 25 Ee t Si E NewPLC High speed Link a High speed Link 01 nd 3 High speed Link 02 c Tm 2 1 je P2P EIP 01 Figure 6 3 5 Screen of Link Enable Chapter 6 XG5000 Setting 6 4 High speed Link Information With High speed link service used to exchange data between communication modules of two or more Stations it provides a checking method of High speed link service status for the user through High speed link information so to confirm reliability of the data read from the destination station via the High speed link In other words the communication module synthesizes the data received up to that time at intervals of a specific time and lets the user know if High speed link operates as in parameters specified by the user through High speed link information where the whole information of Run link HSxRLINK and Link trouble HSxLTRBL to provide the whole information of the communication network and the individual information of HSxSTATE HSxTRX HSxMOD and HSxERH to provide communication status for 64 register items in the pa