Home

Model 4010 Radio Dispatch Console Spec Sheet

image

Contents

1. Spec Sheet Model 4010 Rackmount FEATURES e Full featured console suitable for office environments or dispatch centers e Accommodates up to 12 channels with a mix of control types DC remote tone remote local control E amp M control e Fully field programmable with Any Button Any Function e Individual volume adjustment mute and instant transmit per channel e Simul Select All Mute Alerts and Site Intercom e Built in encoder with optional single button paging steers tones to proper channel and frequency e Channel to channel patch and optional phone patch e Interfaces with outside phone line or analog PBX port ideal for phone patches or administrative calls e Optional Telephone Radio Headset Interface allows one common headset to operate both radio console and separate telephone set e Optional ANI decode display shows unit identification of calling units e MDC 1200 Signaling ANI and Emergency Alert Acknowlege features OVERVIEW The Zetron Model 4010 Dispatch Console is a self contained multichannel radio control console which is available in both desktop or rackmount styles It provides dispatchers with an efficient means of monitoring and dispatching for a system comprised of up to twelve radio channels The M4010 presents the operator with both aural and visual cues to simplify the task of supervising a multichannel communications system The Model 4010 Dispatch Console offers a cost effective hi
2. 0 A at 24 VAC DC Tx control via PTT relay external 48V required 15 standard tones supported programmable no trimmer adjustment 650 2050 Hz High Level Guard Tone duration 120 600 msec Function Tone Duration 40 msec Guard Tone Freq 2175 Hz alterable Tone freq accuracy 0 2 timing accuracy 1 0 Programmable for 2 5 5 5 6 0 11 12 5 and 15 5 mA Operable up to 8K ohm loop resistance Accuracy 25mA Local Cross Busy detection Guard Tone or DC Control detection LOTL optional 13 5 VDC 3 5A max or 95 to 250 VAC 47 to 440 Hz 64 watts max Battery 11 5 to 15 VDC 3 5A max 4 Form C contacts rated 0 5 Ampere 4 Open collector outputs rated 0 25 Ampere 8 TTL inputs 0 5 VDC Zetron Inc All rights reserved Zetron and Zetron and Design are registered trademarks of Zetron Inc All other trademarks are properties of their respective owners See Zetron price list for option pricing Specifications subject to change without notice 005 0447R March 2011
3. and answer telephone calls using the console Paging Formats The built in paging encoder is capable of generating all popular signaling formats The two most popular Motorola GE two tone and DTMF are standard Optional formats include 1500 Hz or 2805 Hz rotary dial Plectron Quick Call 2 2 and 5 6 Tone Expansion Panel The Model 4115 Console Expander provides 60 extra programmable keys for controlling radio channels and instant call paging functions With the Expansion Panel installed the Model 4010R features 136 programmable keys a b at DOBBeB m jel SOUTHERN OC l 1 EL 4115 CONSOLE EX 8 E A g az ns gen F i g 5 SPECIFICATIONS TRANSMIT ELECTRICAL SPECIFICATIONS OTHER ELECTRICAL SPECIFICATIONS Audio Output 10dBm max into 600 ohm line Channel Interface Output Impedance Transmit 600 ohm balanced Idle 600 or 3500 ohms Distortion lt 2 at full output Hum Cross Talk all 50 dB at full output Microphone Input 65 dBm for full output Aux Mic Input 20 dBm for full output Page Spare Input 15 dBm not compressed Frequency Response 3 to 1dB from 250 5000 Hz except guard l Erenodh Channel Control Compression Input level increase of 30 dB above knee of Local Control compression causes lt 3 dB output increase RECEIVE ELECTRICAL SPECIFICATIONS Input Impedance 600 or 10K ohm 4 wire 3500 ohm 2 wire E am
4. the factory programming files Changing the function of a key is simply a matter of using the cursor to select a new function from a menu style list on the computer screen When all selections are made the new configuration is saved on the diskette and printed out for a paper copy When ready the stored configuration may be downloaded to the console in a matter of seconds Configurations can also be uploaded from a console to a PC for storage or modification INSTALLATION AND MAINTENANCE The Model 4010 is fully self contained requiring no external electronics It uses industry standard 25 pair cables and punchdown blocks for interfacing to radios and leased lines Standard or lightning protected connectorized punchdown blocks are available External options such as desk mic and headset jack are also connectorized All line adjustments status LEDs and configuration switches are accessible through the rear panel without any disassembly ON 3 BEF 2 gis me A a x A f The Console operates from 12 Volts DC which is available from Zetron s universal power supply that accepts any voltage from 95 to 250 VAC at 47 to 440 Hz The universal power supply has UL CSA and VDE approvals The clam shell design of the desktop Model 4010 and the easily removed back and top of the rackmount model make access for maintenance and upgrades easy All channel electronics are contained on plug in circuit cards for easy
5. gh performance solution for a wide range of public safety utility and private land mobile radio applications It is specifically designed for police fire EMS railroad and plant security operations Attractive enough for office environments the Model 4010 is rugged enough for sustained 24 7 communications center use Model 4010 Radio Dispatch Console NOLL s A Model 4010 Desktop The Model 4010 can be configured with as few as two channels and grow to twelve channels with the addition of modular channel cards Channel cards may be specified to be compatible with all common local and remote control standards The rackmount 4010 may be equipped with an optional 60 button expansion panel if required OPERATION The Model 4010 has been designed to simplify the task of operating a multichannel system allowing operators to concentrate on the content of their dispatching activities MultiFunction LCD The backlit wide viewing angle LCD serves several purposes It normally shows the time and the audio level During paging it indicates the pager code being sent In the event of a self diagnosed problem the display spells out the problem in plain English ANI codes may be displayed as well Buttons Button functions are clearly labeled and color coded on the key s surface to provide easy function association All primary functions are performed by a single keystroke Indicators The indicators fo
6. ons but it also allows any button to be assigned any available function This eliminates costly upgrades while allowing the buttons to be reconfigured at any time to accommodate new operating procedures or radio system changes Key top labels are removable and do not require engraving allowing the keys to be relabeled as easily as they are programmed Standard key top legends are supplied by Zetron while custom legends may be created in the field using transparent key tops GD cpsw M4010 V2 3 157 189424CM mex Ele Edt Communication Help Position Configuration Available Memory 92 Se m auae Position Layout Done Panel 1 Model 4010 Main Upper Panel Available Memory 92 1 Ch1 Select Ch2 Select Ch3 Select Ch4 Ch5 Ch M4010L M4010 Rx 7 5ma Rx 7 5ma Rx 7 5ma Rx 75ma Rx 7 Sma ma Rx Tx 7 5ma 1x 75 T T ma x 75ma x 7 5ma Tx 7 5ma x 7 5 Ei es g3 BO Chi h Ch h4 Ch5 Ch Ch7 8 ANIDecode D Volume Volume Volume Volume va Sern Ldn t Adjust Panel 1 Key eaea 2 Definition Dialog The Key s Functional Group Rx function Tx function 7 5ma 75 Volur Ve Volume Mute Mute Mute Mute Paj The console is shipped from the factory programmed and labeled to customer specifications with a CD containing the Windows Console Programming System and
7. p M Control Tone Control Line Balance 66 dB at 1000 Hz Rx Sensitivity 30 dBm max at knee of compression adjustable Frequency Response 3 to 1 dB from 250 5000 Hz except guard tone notch Compression Input level increase of 30 dB above knee of DC Control compression causes lt 3 dB output increase Distortion lt 2 Call Light Sensitivity 20 dB below knee of compression Audio Outputs 5 watts into 4 ohms Busy Chan Detect Mute Programmable from 0 to 28 dB or full mute All mute time programmable Power Input PHYSICAL SPECIFICATIONS Size e Desktop 9 high x 18 wide x 14 deep Aux Output e Rackmount 10 5 high x 19 w x 10 5 deep Weight 15 Ibs Dust Liquid Ingress NEMA 1 IEC 60529 IP 30 Operating Temp 5 to 50 degrees Celsius Aux Inputs LE TRON Ee ZETRON AMERICAS PO Box 97004 Redmond WA USA 98073 9704 P 1 425 820 6363 F 1 425 820 7031 E zetron zetron com ZETRON EMEA 27 29 Campbell Court Bramley Hampshire RG26 5EG United Kingdom P 44 1256 880663 F 44 1256 880491 E uk zetron com ZETRON AUSTRALASIA PO Box 3045 Stafford Mail Centre Stafford QLD 4053 Australia P 61 7 3856 4888 F 61 7 3356 6877 E au zetron com Tx Rx Audio pair for 2w 4 Rx Audio pair for 4w PTT relay contact Busy out Busy in X Mute in Supv control main stby Recorder Out Local E amp M Tone Remote DC Remote Telephone tip ring PTT normally open relay contact rated 1
8. r the button s function are located next to the button for clear association For dual functions the adjacent LED indicators use different colors to ensure positive identification The wide viewing angle ensures excellent visibility even across the room Select Unselect Speakers Two speakers provide a left right audio effect making it easy to distinguish whether the call was from the primary Selected channel or some other channel Selecting a channel moves its monitor audio to the Select speaker LE TRON Individual Channel Volume Mute The volume on each channel may be set independently allowing the operator to prioritize listening based on volume The LCD display shows volume percentage allowing accurate settings Single button muting instantly reduces the volume of a channel to a predetermined level Call When channel activity is present the channel s CALL indicator blinks making it easy to locate the source of the call The call indication remains for a few seconds after the call stops in the event the operator is busy with another activity Patch The simplex VOX operated patch can patch together channels to channels or channels to telephone lines The operator may monitor the patch and operate on other channels Transmit The operator may transmit over the selected channel s by pressing the Transmit button or by pressing the optional foot operated transmit switch With Instant T
9. ransmit the operator may transmit over a non selected channel to reply to a call without changing channel selection Monitor This allows the operator to disable coded squelch on the selected channel so the channel may be monitored for traffic prior to transmitting Alert Up to four different alert tones may be transmitted to indicate the type or priority of the dispatch to follow Auxiliary Input Output Operators may control various contact closure operated devices such as lights door locks and voter controls from the console External inputs such as voter displays and alarms may be monitored at the console Instant Call Paging The operator may tone out an entire sequence of pages with the press of a single Instant Call button Paging sequences are automatically routed to the proper channel and frequency eliminating potential human errors Paging sequences may contain self initiating alert tones for indicating specific types of events The button s indicators provide a check list to verify that the proper pages were sent Multiformat capability eliminates the need to have a different encoder for each type of pager decoder PROGRAMMING One of the unique features of the Model 4010 system is that it is FULLY field programmable with the Console Programming System CPS and an IBM compatible personal computer CPS not only allows channels to be configured for various types of base stati
10. replacement or expansion Audio throughout the console remains analog and is not digitized In addition to providing superior audio fidelity this makes audio troubleshooting easier The service manual contains full schematics parts IDs parts lists and theory of operation Factory service spare boards and spare parts kits are available OPTIONS The wide variety of options available for the Model 4010 allow it to be tailored to any dispatch environment MDC 1200 Signaling Allows for an ID code to be transmitted every time a radio is keyed providing user identification for each radio ID transmission may be programmed to occur at the beginning or end of transmission or both When combined with emergency alert acknowledge signaling mobile and portable radios equipped with MDC 1200 protocol can transmit an emergency ANI signal with the press of a button to request immediate help MDC 1200 signaling provides an efficient way for the dispatcher to receive the identification information send an acknowledgment back to the radio and respond to the emergency Gooseneck Microphone The unidirectional 12 inch gooseneck mounts directly to the Model 4010 Desk Microphone The omnidirectional dynamic desk microphone has its own transmit and monitor bars Handset and Cradle When the PTT handset is in the console mounted cradle the console s select speaker is live When the handset is lifted the select audio
11. reverts to the handset earpiece Headset Jack The headset jackbox may be mounted to the side of the console or under a desk writing surface When a headset is not plugged into the jack the console s select speaker is live when it is plugged in the select audio reverts to the headset earpiece Telephone Radio Headset Interface The telephone radio headset interface allows one common headset to be used for both radio and telephone with a volume control for each When the telephone set indicates that it is connected to a line off hook the common headset is switched to the telephone and the console s select speaker becomes live If the operator transmits on the console the headset is momentarily switched back to the radio console When the telephone is disconnected from the line the headset reverts back to the console and the console s select speaker becomes muted Requires off hook contact closure from telephone Footswitch Footswitches are available for controlling selected channel transmit and monitor allowing hands free operation Automatic Number Identification ANI ANI codes generated by mobile or portable radios are shown on the console s LCD display when M4010 is equipped with an ANI decoder Phone Patch The phone patch option allows the console operator to establish a patch between any radio channel and a telephone line This option also allows the operator to originate

Download Pdf Manuals

image

Related Search

Related Contents

TAFCO WINDOWS NU2-127V-W Instructions / Assembly  Bedienungsanleitung - Lohrmann  Inogen Universal Power Supply Instructions for Use  CONCORRÊNCIA PÚBLICA 019/2010  PORTEZ LES BONS VÊTEMENTS !  Istruzioni per l`uso Sensore ottico della distanza O1D100  AR-EF1 - Printertec  USER INSTRUCTIONS The dream™ SerieS  Westinghouse Bonneville Two-Light Outdoor Flush Fixture 6230300 Instruction Manual  user instructions  

Copyright © All rights reserved.