Home
Product Manual - Kyoto Kagaku America Inc.
Contents
1. MW12 OO Z Caution Do not mark on the model and other components with pen nor leave printed materials contacted EAR I Examination Simulator aes Ink marks on the models cannot be removed Instruction Manual Table of Contents Introduction Manufacturer s Note 66 0 os 66 ncet enw en sacs P 1 Before You Start DOs and DON IG lt 423 4 bees se cies cseene sence uss P 2 SED IN CII CS 662s oo eh oe oP hbe ce eieer awe ne ta P 3 Preparation EPER TE EEPE TEE EE E E E T P 4 Training SESSIONS 66 66s e heh we Keds ee terari P 5 Training Sessions 0 cece ee eee P 6 After Training C KYOTO KAGAKU co t1p Introduction Manufacturer s Note Manufacturer s Note Please read the instruction carefully before use Before Use MW12 EAR Examination II has been developed for the training of medical professionals only Any other use or any use not in accordance with the enclosed instructions is strongly discouraged The manufacturer assume no responsibility for any accident or damage resulting from such use Should you have any questions on this simulator please feel free to contact our distributor in your area or KYOTO KAGAKU at any time Our contact address is on the back cover of this manual Product Features The New Ear examination Simulator Il is designed to acquire safe and reliable skills in the examination of the external acoustic meatus and tympanic membrane with a direct o
2. ful insertion is warned by a beep self learning mode or lamps instructor mode When the tip of the instrument passes bony part of the ear canal yellow warning lamp and intermittent beep When the tip of the instrument reaches eardrum red warning lamp and a continuous beep To stop the continuous beep turn off the power switch Set the training mode Training mode can be set by the mode change switch on the back of the shoulder part 1 Self learning mode warning with sounds 1 2 Instructor examination mode warning with Set earing mode J e Instructor lamps only Cannan aes I d oe xno CE AD C OOTO cade oo Power swich Mode change swich Trouble shooting If the tip of the instrument is clearly in the warning zone and no warning indicator works 1 ensure that the power switch is on then if necessary 2 replace the batteries with new ones Training Sessions After the training Training Sessions Flexible neck and ear The neck can be tilted to simulate positioning of patient s head The soft and supple ear allows training in straightening the canal by pulling the ear lobe TULL P Be sure to use FB type external ears Put the included ear wax small toy or a sponge in the ear canal by a small spoon Then set the ears to the head Ensure to switch the case switching dial to FB After Training After use Remove all the simulated ear wax s
3. mall toys and sponges from the FB Ear Remove the batteries from the box and store them separately For cleaning wipe the surface of the manikin and ear models with soft cloth moistened with water or alcohol Dry the manikin naturally and dust the surface with talcum powder Do not expose the manikin and accessories to high temperature and high humidity Don t mark on the model and other components with pen or leave printed A N Caution EEEE RAEE Ink marks on the models will be irremovable For inquiries and service please contact your distributor or KYOTO KAGAKU CO LTD AN A EF ILRI Me EABHAMNEADISCLTKSL en HRM 4 VOAMINENTHAR lt K BVETF ARGC DIY COSMVSNEPFBSSCSWELES SFMCIMSALFOMBE BL lt d FEC HK RAAF CHB lt ES E Nine sets of cases and setting number EO to bORM CRESS 1 normal 2 serious otitis 3 mucoid otitis 4 chronic otitis media 5 acute suppurative media SOM media MOM with perforation otitis media AOM 2 HHK SARE 3 HRH MAIE 4 HER REFIL 5 PEK AHIRE 6 cholesteatoma 7 tympanosclerosis 8 traumatic perforations 9 cerumen block 6 Bike 7 XECE 8 IHA TEIRRI 9 HRE 2060 E KYOTO KAGAKU co LrD oa MaB URLehttp www kyotokagaku com e mail erw kyoto kyotokagaku co jp W Main Office and Factory W LA Office for North and South American customers 15 Kitanekoya cho Fushimi ku Kyoto 612 8388 Japan 3109 Lomita Boulevard Torrance CA 90505 USA Telephone 81 75 605 2510 Teleph
4. nic solvent Do not mark on the simulator models with pen or leave any printed materials in contacted with the surface Ink marks on the models will not be removable AOAO Set includes Set Includes Before your first use ensure all components listed below are included in the unit Set includes 1 manikin head and shoulder 4 types of ear units 1 pair each Exam Ear normal Exam Ear stenosis FB Ear normal FB Ear stenosis 1 set of foreign body removal kit simulated ear wax small toy small sponge fragments and a spoon 2 AA batteries Specifications manikin size approx 42x21x38cm 1 5kg Type of the ear is marked on the rear surface of each ear lobe Type Exam Ear normal Exam Ear stenosis FB Ear normal FB Ear stenosis Replacement Parts 11391 010 accessories for MW12 4 types of ear units 1 pair each Exam Ear normal Exam Ear stenosis FB Ear normal FB Ear stenosis 1 set of foreign body removal kit simulated ear wax small toy small sponge fragments and a spoon Preparation Preparation Setting of the ears Choose a pair of external ears that fits the intended training scenario Insert the ear into the opening as shown in the photo below Ensure to orient the ear so that the sliding guides on the ear unit and the wall of the opening match together To detach the ear please grasp gently around the base of the pinna and pull straightout pe
5. one 1 310 325 8860 Facsimile 81 75 605 2519 Facsimile 1 310 325 8867 C 2 malas URLehttp www kyotokagaku com e mail erw kyoto kyotokagaku co jp Bat Ty BR mss T 612 8388 Raw AR KAS eH 56H 7113 0033 RRABMRKAM T A268 65 TEL 075 605 2510 1838 NREGAS T A eh FAX 075 605 2519 TEL 03 3817 8071 23 FAX 03 3817 8075 The contents of the instruction manual are subject to change without prior notice No part of this instruction manual may be reproduced or transmitted in any form without permission from the manufacturer Please contact manufacturer for extra copies of this manual which may contain important updates and revisions Please contact manufacturer with any discrepancies in this manual or product feedback Your cooperation is greatly appreciated ARBONA 4 PRHRBLICREFTSCEMBGVIRG AZONKRO MBb L lt IEAA Stic CES RRTSZCCABECKT SEON D TZARA PENRE BRADE DANZEN LED Yeh L lt KARE EK lt TES 2013 11
6. rpendicularly to the head Please 0000000000 HHOHOHHOHOHOHOHOHOOHO8 OOOOH OOHOHOHHHOHO000OH0808O8080008088 080800888 A note Please note Do not mix up the different types of ears for different trainings Examination with an otoscope Use Exam Ear s mark 1 or 2 Foreign body removal Use FB Ear s mark 3 or 4 Setting of the batteries The battery box is at the back of the shoulder unit Push the tab at the right side of the lid to the left and then pull it to open the lid Set two size AA batteries in the box Ensure the direction of the batteries The position of positive or negative electrodes is indicated in the box After setting the batteries replace the lid Put the two small tabs to the indents at the left side of the battery box then push the lid to close Turn on the power switch when training session begins e Self learning e Instructor Examination power switch Please note Use size AA batteries and ensure direction of them 4 Training Sessions Training Sessions Set the case for training The cases can be switched over by the switch dial The number appears in the window indicates the chosen case Refer the table on the quick manual To practice foreign body removal set the dial to FB and set the FB Ear type of external ears Otherwise you may damage the ear drum images Warning against painful insertion The tip of the instrument is localized by sensors and harm
7. toscope The model warns against painful insertion Skills to be learned includes safe use of an otoscope differentiation of typical ear problems and earwax foreign body removal Warning against painful insertion with or without beep self learning mode with a beep instructor mode silent Major 9 cases are prepared includes 1 normal Quick switching between cases 2 sizes of ear canals normal and stenosis Anatomically correct soft ear model that allows training in straightening the auditory canal by pulling the auricle Training with a real otoscope The manikin neck can be tilted Training is possible with both left and right ears IOA OR tla DOs and DON Ts ANE DOLE Tale BLO A E DOs Handle With Care The materials for the models are a special composition of soft resin Please handle with the utmost care Use a specular of recommended size Size 4 Ensure the direction of the batteries Store the simulator in the case at room temperature Keep away from heat moisture and direct sunlight For cleaning wipe the mannequin with a soft cloth which has been moistened with water or alcohol After drying the manikin please dust the head with baby powder DON Ts Do not insert an otoscope too deep as this may cause damage to the eardrum Do not rotate the switch dial too quickly as this may cause mechanical trouble in the system Do not ever wipe the simulator with thinner or orga
Download Pdf Manuals
Related Search
Related Contents
XGT Panel User Manual Manuale tecnico iPhone OS Einsatz in Unternehmen 2 Toccando - Alpine Europe FX3U-128ASL-M USER`S MANUAL Crossflow AMF TM 201 High Efficiency Media User Manual and Mode d`emploi SG製品含有化学物質管理基準〈第 2版〉 - 三光産業株式会社 (Sanko 取扱説明書 - Panasonic Copyright © All rights reserved.
Failed to retrieve file