Home
Adobe Acrobat PDF document
Contents
1. Improx EC Product Specification Catalogue The ImproX EC Ethernet Controller is a fully Ethernet compatible Controller for use in the IXP400i Access Control System The Controller boasts both an RS485 Controller Port Port 1 and an Ethernet Port allowing use of either When connected to the Ethernet Port the Controller offers communication speeds and capacity not yet seen in similar systems The Controller comes standard with an RS485 Terminal Port Port 2 able to support up to 32 full Anti passback doors on board Diagnostic LEDs and a System Backup Battery The Battery allows between 4 to 6 hours of uninterrupted power The ImproX EC Ethernet Advanced Controller is the next generation of Ethernet hardware promoting quick and easy installation across a LAN or WAN with bandwidth friendly communication protocol Key Features General Hardware e ARM920T Microprocessor Core operating at 200 mips million instructions per second e Linux Operating System e 64MB SDRAM Memory and 8 MB Flash Memory e LEDs indicate transmit and receive line activity for diagnostics e A Real Time Clock RTC with a 3 V Lithium Backup Battery providing 5 years stand by operation Remote Firmware download capability e Supports a secure logon when changing Controller Configuration settings using the Ethernet Discovery Utility An Ethernet Controller Port for connection to an Ethernet Switch or Hub or other network
2. device e AnRS485 Controller Bus Port for connection to other ImproX EC Ethernet Controllers e An RS485 Terminal Bus Port for connection to up to 64 Terminal Fixed Addresses e Operation from power inputs in the range 10 V DC to 30 V DC e Configurable dynamic memory providing 5 different configurations 300 000 Tags and 500 000 buffered transactions 250 000 Tags and 600 000 buffered transactions 200 000 Tags and 700 000 buffered transactions 150 000 Tags and 800 000 buffered transactions 100 000 Tags and 1 000 000 buffered transactions Power Input Fail and Battery Low signal reporting e 48 Hour Hibernation Mode for extended battery backup of the ImproX ECII Ethernet Controllers database including transactions ImproX EC Ethernet Controller XEC900 0 0 GB XX IPS970 0 0 GB XX Aluminium Extruded Cabinet XEC900 Robust Aluminium enclosure Fully incorporated uninterrupted Power Supply with trickle charge and battery management Incorporated 6 V 3 Ahr Sealed Lead Acid Battery providing 6 hours full operation Power Supply Combo IPS970 e A3Amp Switch Mode Power Supply providing 13 8 V DC Integrated automatic switch over to Battery operation on Mains Failure Compact Mild Steel Cabinet accommodating the Power Supply Controller and a Sealed Lead Acid Battery e Five Quick Click Glands for easy wiring e An internal power supply provides the battery ch
3. relative humidity at 40 C 104 F non condensing Approvals CE Approval EN 301 489 1 EN 301 489 3 and EN 300 330 1 FCC Approval Pending Dust amp Splash Resistance Designed to work in an indoor dry environment similar to IP20 The Power Supply Combo is therefore not sealed against water Drop Endurance 1 m 3 28 ft drop in packaging Electrical Specifications Power XEC900 Aluminium Extruded Cabinet Input Voltage 10 V DC to 30 V DC Power Requirements Current mA Power W Input Voltage 10 V DC 420 4 2 Maximum Input Voltage 30 V DC 140 4 2 Maximum Permissible Input Supply Ripple Voltage Max 1V pp at 50 HZ Power Input Protection Reverse polarity on DC power inputs over voltage and over current protection are provided on the Controller Battery Type 6V3Ahr Sealed Lead Acid Battery Length 133 mm 5 in Width gt 34mm 1 in Height 65 mm 3 in including the terminals Battery Life 4 6 Hours uninterrupted operation 48 Hours Power Shutdown Hibernation Mode Real Time Clock Backup Battery RTC Battery Type 1x3 V CR2032 Lithium cell Battery Battery Life 5 Years with power OFF IPS970 Power Supply Combo Power Input Input Voltage 85V AC to 265 V AC at 50 60 Hz Power Output Output Voltage 3 0 V DE t0 3 V_ DE Mains Power On Output Current 2 A continuous Power Output Terminals NOTE The Power Supply Combo includes a 3 A Switch Mode Power S
4. 00 selectable via the Protocol Data Format 8 data bits no parity 1 stop bit Communications Protocol ImproX Secure Communications Protocol Line Termination Provision is made for line termination Default Mode Receive Mode Memory RAM Non volatile 64 MBytes Flash ROM 8 MBytes Other Anti tamper Switch 2 Internal Switches XEC900 0 0 GB XX Anti tamper Switch 1 Internal Switch IPS970 0 0 GB XX Factory Defaults Test Modes Power on Self test RAM Flash ROM RTC Baud Rate RS485 1 Controller Port 38 400 RS485 2 Terminal Port 38 400 Page 2 User Interfaces Controller Power Indicator Power LED Diagnostic Indicators Incoming RS485 1 Controller Outgoing RS485 1 Controller Incoming RS485 1 Terminal Outgoing RS485 1 Terminal Link Speed LED Ethernet Duplex Mode LED Ethernet Link Active LED Ethernet CPU Usage CPU Running CPU Fault Red LED internally visible Flashing Green LED internally visible Flashing Red LED internally visible Flashing Green LED internally visible Flashing Red LED internally visible Flashing Red LED internally visible Flashing Red LED internally visible Flashing Red LED internally visible Red LED internally visible On Idle Off Busy Red LED internally visible On Yes Off No Red LED internally visible On Fault Condition Off Okay SERVER TCP IP up to 64 Door Control
5. arging facility at 6 8 V and 350 mA When used with ImproNet Software V7 40 and upwards e Tags per person 8 e Tagholder Access Groups per Tag 10 Access Groups total 10 000 e Active System Events 8 000 e Actions 50 000 Physical Specifications XEC900 Aluminium Extruded Cabinet Length 168 mm 7 in Width 197 mm 8 in Height 89 mm 4 in Approximate Weight 2 kg 4 Ib Battery included Cabinet Material Aluminium Colour Black IPS970 Power Supply Combo Length i 305 mm 12 in Width gt 295 mm 11 in Height 77 mm 3 in Approximate Weight 3 kg 7 Ib excluding Controller and Battery Cabinet Material Mild Steel Colour Black Environmental Specifications XEC900 Aluminium Extruded Cabinet Operating Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 15 C to 50 C 5 F to 122 F Humidity Range Oto 95 relative humidity at 40 C IN 104 F non condensing impro technologies ACCESS CONTROL Approvals CE Approval EN 301 489 3 and EN 304 489 1 FCC Approval Pending Dust amp Splash Resistance Designed to work in an indoor dry environment similar to IP30 The Controller is therefore not sealed against water Drop Endurance 2 m 7 ft drop in packaging IPS970 Power Supply Combo Operating Temperature 25 C to 60 C 13 F to 140 F Storage Temperature 40 C to 80 C 40 F to 176 F Humidity Range 0 to 95
6. lers per System Controller BC pc pc ITITI Related information For extra information relating to this product refer to the e ImproX EC Hardware Installation Manual XEC300 0 0 GB XX e Ethernet Discovery Utility Software User Manual XEC301 0 0 GB XX e ImproNet Software Installers Guide IXP362 0 0 GB XX e ImproNet Webhelp IXP393 0 0 GB XX Ordering information Order the ImproX EC Ethernet Advanced Controller using the following Part Numbers e XEC900 0 0 GB XX ImproX EC Ethernet Advanced Controller housed in an Aluminium Cabinet e IPS970 0 0 GB XX ImproX IPS containing an ImproX EC Controller Warranty Details This product conforms to our Warranty details on www impro net KEY SYSTEM Controllers BC DOOR Controllers Each Door Controller is compatible with specific Readers Always select the correct Readers for the chosen Door Controller O DOOR Readers hf TAG REGISTRATION Reader POWER Supply Figure 1 ImproX EC Ethernet Overview Page 3 SERVER KEY SYSTEM Controllers BC DOOR Controllers up to 64 Door Controllers per System Controller Each Door Controller is compatible with EC specific Readers Always select the correct RS485 Readers for the chosen Door Controller pc DC DC 9 g g DOOR Readers ral up to 64 Door Controllers per System Controller E RS485 DC DC DC hd TAG REGISTRATION Reader docoey o Figu
7. re 2 ImproX EC RS485 Overview This Product Specification Catalogue applies to the ImproX ECII Ethernet Controller XEC900 0 0 GB 03 and IPS970 0 0 GB 00 The last two digits of the Impro stock code point to the issue status of the document or product ImproX ECIl Product Specification Catalogue LATEST XEC350 0 0 GB 03 Issue 04 March 2009 ISSUE XECII psc en 04 docx Page 4
8. upply which provides two outputs both with a voltage of 13 8 V DC The combined current supply from both outputs may not exceed 2 A The remaining 1 A is used for battery charging and system requirements Battery Type 6V3Ahr Max Sealed Lead Acid Battery Length 151 mm 6 in Max Width gt 65 mm 3 in Max Height gt 99 mm 4 in including the terminals Max Real Time Clock Backup Battery RTC Battery Type 1 x 3 V CR2032 Lithium cell Battery Battery Life 5 Years with power OFF The following specifications are common to both the Aluminium Extruded Cabinet and the Power Supply Combo Controller Bus Ethernet Port Connection Standard Ethernet RJ45 connector 10 100 Mbps half or full duplex Protocol TCP IP UDP RS485 1 Controller Port NOTE The RS485 1 Controller Port connection details only apply to ImproX EC Controllers with Firmware V7 16 upwards Configuration 38 400 Default Electrical Interface RS485 Baud Rates i 9 600 19 200 28 800 38 400 and 57 600 selectable via the Communications Protocol Data Format 8 data bits no parity 1 stop bit Communications Protocol ImproX Secure Communications Protocol Line Termination RS485 Provision is made for line termination Default Mode Receive Mode Terminal Bus RS485 2 Terminal Port Configuration 38 400 Default Electrical Interface gt R8485 Baud Rates 9600 19 200 28 800 38 400 57 600 and 76 8