Home
User Manual
Contents
1. 10 BaseT Ethernet connection established Run Flashing Green system is ready Serial 1 Green connection established Flashing Green data is transmitting DI DO Green connection established Flashing Green data is transmitting DI1 DI8 Green Status ON DOI DO8 Green Status ON RS 232 422 485 10 100M SW Reset 12 30VDC SCB A08 Ethernet IO Module Trusted Video Management NUUO Surveillance System Accessory 2 2 Pin Definition Name Description RS232 422 485 RS232 422 485 interface support RX Receive RX Receive TX Transmit TX Transmit GND Ground 10 100M 10 100 Mbps Ethernet SW Dip Switch Reset Hardware reset button 7 30VDC 7 30 VDC support 5 Power DI Digital input Channel 1 DI2 Digital input Channel 2 DI3 Digital input Channel 3 DI4 Digital input Channel 4 DIS Digital inout Channel 5 DI6 Digital input Channel 6 DI7 Digital input Channel 7 DI8 Digital input Channel 8 GND Ground b Power DOI Digital output channel 1 COI Common usually is ground DO2 Digital output channel 2 CO2 Common usually is ground DO3 Digital output channel 3 COS Common usually is ground DO4 Digital output channel 4 CO4 Common usually is ground GND Ground b Power DO5 Digital output channel 5 COS Common usually is ground DO6 Digital output channel 6 CO6 Common usually is ground DO7 Digital output channel 7 CO7 Common usually is ground DO8 Digital output channel 8 CO8 Common usually is
2. 1 TCP 4001 Not mapped Notconnected Virtual COM List Serial Server List Ready Note Port 4001 for I O box 5 2 Configuration SCB A08 Highlight the serial server in the Serial Server List window and double click to open the Server Properties window The Server Properties window is used to configure and store the SCB A08 configuration settings After configuring as needed click Update to store the configuration in the server and click Yes to restart the SCB A08 to make sure all settings are changed to conform to the desired application NL Trusted Video Management NUUO Surveillance System Accessory 5 3 Server Properties Step 1 Double click SCB AO08 list on SCB Manager search tool and open server properties Server name Serial number Password DHCP IP address Disable v serial port Baud rate Data Stop bits Parity Flow control Delimiter HEX 1 Delimiter HEX 2 Force transmit Port status TCF UDP port 0 x100ms 0 65535 Not Connectec 14001 R5232 192 168 2 1 255 255 255 0 192 168 2 254 00 06 64 62 00 06 Netmask Protocol Serial port mode Gateway MAC address Serial timeout Power up n 255 255 255 255 o 0 65535 sec Connection at 0 0 255 min Maximum connection Server Remote IP address TCP alive timeout Version amp Date 1 8 33 amp 100613 Connection mode Link status 100 Full Duplex Hardware ID PP
3. Ethernet packet and sent out the Ethernet port Suggest use default setting Force Transmit This field allows the user to set a maximum time limit between transmissions of data The value set in this field multiplied by 100 ms determines the Force Transmit time When the elapsed time reaches the time configured in this field the TCP IP protocol will pack the data currently in the serial buffer into a packet and send it out the Ethernet port Suggest use default setting A Port status This field indicates whether a serial port is connected to a server or by a client TCP UDP port The TCP UDP Port defines a communication port number In all modes of operating Virtual COM Direct IP and Paired modes both the TCP UDP Client and server port settings must match For I O box configuration port is 4001 Serial port mode This allows configuration of the serial server for the following modes of operation xdi Trusted Video Management NUUO Surveillance System Accessory e Console When this mode is selected and the server is updated a PC running a communication program such as Hyperterminal can communicate with the serial server via the Console Mode serial port Port 1 on SCB A08 displaying the Server Properties screen and allowing configuration of the server and its ports under 4000 port e Upgrade When this mode is selected and the server is updated firmware can be uploaded into the serial server via the Console Mode seria
4. SCB AO08 will reset itself to complete the upgrade process Ti Trusted Video Management NUUO Surveillance System Accessory 5 6 Configuration Here we take NUUO surveillance system Mainconsole for example Step 1 Open Mainconsole on PC Step 2 From Mainconsole tool bar click A button Step 3 A menu opens Step 4 Click Setting System Setting Step 5 Setting page opens featuring a series of tabs Step 6 Click I O Device tab I O Device tabbed page opens Un Setti id General Camera WO Device PTZ Config Hotline Address Book Moni IO Device Setting Module Device G testtest SCB A08 Biz SCB C28 lg Arecont AV5105 IP Camera ll Arecont AV5105 IP Camera 3 ll Arecont AV5105 IP Camera ll Arecont AV5105 IP Camera il Arecont AV5105 IP Camera lg Arecont AV5105 IP Camera lil Arecont AV5105 IP Camera ac Module name testtest Device SCB A0S8 IP Address 192 168 3 63 Port 4007 ID Addr 01 e Trusted Video Management NUUO Surveillance System Accessory Step 7 In Module field dub SCB A08 with a name Step 8 By Device specify SCB A08 model name Step 9 By Port enter 4001 for I O Step 10 By ID select the ID address for SCB A08 Note First device selects Addr 01 and so on I O Device Setting Module name Device SCB 408 v IP address 19216821 4001 Addr 01 Step 11 Run fest If the window detect IO box successfully pop up the setup is
5. successfully made Detect IO box successfully wr Step 12 Click OK and quit setting a
6. 2001 Cancel Server name The server name is user configurable It is recommended users with more than one SCB A08 connected to the LAN assign a new name to each When the Manager software searches for SCB A08 on the LAN it will display the server name allowing the user to distinguish between SCB AO08s Serial number each SCB A08 has a unique serial number This is fixed and cannot be changed Password Entering a password activates a security feature on SCB A08 Once a password is entered it will be required to access the menu and make changes DHCP DHCP servers are a part of numerous LAN management systems The DHCP field has two selections Enable or Disable Arrow to the desired selection and select enter When enabled SCB A08 will send a DHCP request to the DHCP server which will assign a dynamic IP address netmask and gateway to the SCB AO8 If a DHCP server is not available on the network the SCB A08 will time out after 10 seconds and the default values will remain When DHCP is enabled the IP address Netmask and Gateway fields become inaccessible and cannot be changed by the user IP address SCB A08 default IP address is 192 168 2 1 A static IP address can also be assigned in this section of the menu A dynamic address assigned by the DHCP server may change if the SCB A08 loses the Ethernet connection or power is removed The host client communication software requests a connection to the specific IP address of the seri
7. NUUO Surveillance System Accessory 5 Using Search Tool This chapter introduces several functions of search tool Searching for SCB A08 connected to the network Displaying and changing the configuration of SCB A08 Upgrading the SCB AO08 firmware Monitoring port status Saving and loading configuration files Once the SCB A08 is connected to LAN the search tool wil be able to search LAN for all connected SCB A08 and will display them in a window by name and IP address 5 1 Searching LAN for SCB A08 Step 1 Select search tool SCB Manager in the program file menu As soon as the search tool SCB Manager opens it will initiate Searching SCB A08 and after a few seconds the Serial SCB AO8 List will display all SCB AO8 on the network Step 2 To manually initiate a search for SCB A08 on the menu side bar select Searching Server button The Search Setup box will appear It provides two options for searching for SCB A08 on the network Specify the IP address of the SCB A08 Search all reachable SCB AO8 Enter the IP Address assigned to the desired SCB A08 or click Search all reachable SCB A08 then OK The Searching window is shown until all active SCB A08 on the LAN are listed in the Serial Server List window mass Server View Exit Help Ls t a CE Firmware X Virtual Uninstall Monitor Install Upgrade COM Con Eau Virtual Port Status Virtu SCB A06 132 168 2 1 TCP 4000 Not mapped Not connected SCB A08 132 168 2
8. NUVO Trusted Video Management SCB A08 User Manual Ver 1 0 131218 00 Trusted Video Management NUUO Surveillance System Accessory TABLE OF CONTENTS TABLE OFC ON IEN E DRE 49 4 011 6 ss 2 MAI O E or O o UU O E 55 E E E E E EE 3 SCAN elsi AA A t 4 1 3 System REQUIESMIEN SSWE T n 4 NN eleelea RU 4 Ro uev o Anne 4 NOSE 5 5 LA 2 DADIS AA A PPP CR NR PE e O HEO YF EG R 7 PT lO Mt UU FO OO OO EE EE o eS UP US OO NEF RO FF Y FF FAR FF Y FAN Y 8 Ao el 6 ig ole e ao ae o q oriris rnr ara E E a 9 2 Pia e Nem 9 PAST AA cobstceserscmeh E seadacaupendacibacuenesaenecsiecteaecdauueasatadieonaresesnentedtesant 10 3 NETWORK DEPLOYMENT DIAGRAM arpas arnes 11 2 PAKO N AKE S EIP _ FT C lt 11 A Connect SCB A08 to Server PGC RUIT 11 A e e goto Ex iNo E39 ele PTT o Pe 12 3 TN EBRO TOOL ea 13 SN Searching LAN TOS EDAD aaa 13 2 Gee CO i AAA AAA hes laceesendede shoo tacdasensedeiboe 13 Po q E E EEA AE E 14 el e e U a A EE co 17 A VV CO OVET iste m m 18 eo elo lo o A 19 SEME sue ee SEE 20 Trusted Video Management NUUO Surveillance System Accessory 1 Introduction SCB AO8 is an I O box to intermediate the communication between a surveillance server and multiple peripherals It joins up all the major components i
9. al server If the DHCP reassigns a different IP address the software will not be able to communicate with the hardware It is recommended to use a static IP address A static IP address is permanent and will not change unless changed in the menu In most cases the network administrator establishes the static address to be use Netmask The default LAN netmask is configured for a Class C adaress This may reconfigured by the user MAC address The MAC address is not adjustable This is assigned in the factory Every Ethernet device manufactured has its own unique MAC address Version amp Date The currently loaded version of the firmware and when it was released are shown here Link status Link status automatically displays the type of Ethernet connection It will either display 10 BaseT or 100BaseTX in full duplex or half duplex This will depend on the LAN switches hubs used in the LAN topology Serial port This field indicates the number of the port for with serial server properties are currently being displayed Changing the number in this field will cause all the other fields to display the properties for the MUT Trusted Video Management NUUO Surveillance System Accessory specified port Before changing ports any change to properties must be Updated Saved or SCB A08 will not retain them Suggest use default setting Baudrate The serial port baud rate on SCB A08 must match the serial baud rate of the connected device Su
10. ggest use default setting Data Parity Stop This setting will have to match the data format of the connected device Suggest use default setting Flow control The flow control setting must match the connected serial device Suggest use default setting Protocol Select TCP or UDP protocol If the application does not require a UDP connection select TCP TCP guarantees reliable communication with error checking whereas UDP provides faster transmission When UDP mode is chosen the Serial timeout TCP alive timeout Connection mode Connection at Maximum connection and Remote IP address fields are replaced with the following three fields Destination IP address range Port number and Source IP address range In this mode the server can be configured to broadcast data to and receive data from multiple IP addresses Four IP address range fields are provided Suggest use default setting Serial timeout Default is O or no timeout Setting timeout to any value between 1 and 65535 seconds activates it If communications are idle for specified timeout value the serial server will reset and make itself available for another connection Suggest use default setting TCP alive timeout This monitors TCP activity If TCP activity stops for the length of time specified in this field the connection will be closed This field can be set to any value between 0 and 255 minutes If zero or no value is entered into this field the server will not di
11. ground Trusted Video Management NUUO Surveillance System Accessory GND Ground 2 3 Digital I O Hardware Connection SCB A08 bottom has eight switches to set Dry Contact and Wet Contact 2 3 1 Digital Input A Digital Input Dry contact 1 DH 2 DI2 DI3 4 o N DM 5 DI5 DIG DI7 DI8 COMMON B Digital Inout Wet contact o Or 1 Dn 2 DI2 3 DI3 i O Did E DIS 6_ DI6 DI7 j DIS E COMMON 10 Trusted Video Management NUUO Surveillance System Accessory 2 3 2 Digital Output When Relay turn on DO and CO will be a circuit A AC source AC Source 110Vac 230 Vac F j J AS 232 422 485 107 100M SW Reset 12 30VDC DI DO Link SCB A08 ie Ethernet IO Module Serial 1 DoD BO BD OD OD Db D D b D DB Db D LO ITKI I OI 00000000 4 12348878 DODDDDDDG DCDCDCDCG DCDCDCDCG pIIIILILIN OOOOOOOON 00000000N OlaaasesTRBDDII223344DD5565677B8D B DC source DC Source 5 24 VDC RS 232 423 485 RETTO 10 10004 SW Reset 12 WIWDC AXXX m oh m 4 DI DO Lin SCB A08 Run Ethernet IO Module Serial 1 D D D DD D D D D D n DD D BD GB II 1111000 1 00000000 123488678 12348878 DDDDDDDDG DCDCDCDCG DCDCDCDCG hlliILIIIIN ODOOOOOON 00000000N OIza45678DD11223344DD5566TTB8BBD 11 Trusted Video Management NUUO Surveillance System Accessory 3 Network Deployment Diagram This diagram shows how server and all in one I O box A08 are deployed within the surve
12. illance network to work KEIKAN X SCB A08 Hemet BO odia 3 a 3 Surveillance System Fig 3 Network Deployment Diagram 4 Hardware Setup This chapter combs through the necessary setup for the major components in the surveillance network including l I O box SCB A08 2 Windows based server PC 4 1 Connect SCB AO08 to Server PC Step 1 Connect SCB A08 to PC with Ethernet cable and apply power Step 2 On PC install SCB A08 search tool Insert NUUO SCB A08 CD in CD ROM will automatically launch the Install Shield Wizard If the Wizard does not run automatically please enter Computer and click the CD DVD ROM SCB A08 search tool is downloadable at www nuuo com gt Download Once search tool is successfully installed PC auto detects SCB A08 Organize v System properties Uninstall or change a program Map network drive Open Control Panel i X Favorites 4 Hard Disk Drives 2 BE Desktop ACER C volume E E 3 amp Download O 2525 1 Dropbox On Recent Places 4 jusic Autodesk 360 i Pictures ac Folda ideos j Computer EL ACER C dd DVD RW Drive D PNI Setup a volume E E gt Autodesk 360 lt Network a PNI PC Workgroup WORKGROUP Memory 4 00 GB 5 y Processor Intel R Pentium R CP zT Trusted Video Management NUUO Surveilance System Accessory Setup iz preparing the Install hieldA Wizard which wall quide mou th
13. l port or a virtual COM port mapped to the number of the Console Mode serial port under 4000 port e Default When this mode is selected and the server is updated it will revert the server to its default configuration under 4000 port e RS 232 When this mode is selected and the server is updated the selected serial port will become a RS 232 serial port on the server e RS 422 When this mode is selected and the server is updated the selected serial port will become a RS 422 serial port on the server e RS 485 When this mode is selected and the server is updated the selected serial port will become a RS 485 serial port on the server Connection at When the Connection Mode field is set to Client or Client no heartbeat this field becomes active allowing the SCB A08 acting as a client to connect to the server either on Power up or on Data Arrival first character arriving Maximum connection When the Connection Mode field is set to Client or Client no heartbeat this field becomes active allowing the SCB A08 acting as a client to connect to the server either on Power up or on Data Arrival first character arriving Suggest use default setting Remote IP address This is a security feature that is activated when the IP address of the desired client is programmedi into the remote IP Address setting of the menu This tells the SCB A08 to communicate with only the listed IP address and to filter out all other requests for c
14. n 5 6in 1 Tin WxHxD Weight 300g Certifications GE FCC 1 5 Packing List NUUO I O Box SCB A08 x1 Adapter US Power Adapter DC 12V x1 EU with EU plug adapter Warranty card x NUUO SCB A08 CD ROM xl including NUUO search tool NUUO user manual and NUUO troubleshooting pup Note The warranty will only be honored when equipment use original factory shipped power adapters NUUO will not be responsible for 3rd party power adaptors and any issues they might cause Trusted Video Management NUUO Surveillance System Accessory 2 Overview To apply SCB AO8 to your surveillance system get to know it first Take a look around SCB A08 The illustration below depicts SCB A08 by top view and side view with all major components and dimensions called out 10 100M SW Reset 12 30VDC SCB A08 Ethernet IO Module Fig 1 Overview 140 6 Fig 2 Side View eS Pin Terminal block 6 Serial port DTE BD 9 male bot ta Trusted Video Management NUUO Surveillance System Accessory 5 de Be 29 1 e Fig 3 Pin Terminal block Lp eon 3 eo jaon von ou TT 6789 DB9 Male Fig 4 Serial port DTE BD 9 male Lo oo eon L3 eo aon e ow e pm a Cs es me palm Trusted Video Management NUUO Surveillance System Accessory 2 1 LED Definition Name Description Link Green 100 BaseTX Ethernet connection established Yellow
15. n your surveillance network to deliver your prospective management and protection over your property This manual combs the hardware software setup for SCB A08 Software wise A08 needs the server relies on NUUO surveillance system to bring all the peripherals under control Easy to mount and flexible in communication SCB A08 will be the pivot in your surveillance network Thank you for choosing SCB A08 10 100M SW Reset 12 30VDC SCB A08 Ethernet IO Module Trusted Video Management NUUO Surveillance System Accessory 1 1 Key Features 8 inputs dry contact or wet contact and 8 relay outputs provided Supports 10 100 Mbps Ethernet Status LED for each channels DIN rail optional Supports LAN and WAN communications In server mode supports individual 8 client sessions socket Management access password protected Supports socket connection TCP server TCP client and UDP Heart beat connection ensures reliable TCP connection against power failure or network disruption Hardware watchdog 1 34 sec Trusted Video Management NUUO Surveillance System Accessory 1 2 OS Reavirement 32 bits MS Windows XP Vista Win 7 64 bits Win 7 Win 8 Win Server 2008 R2 Win Server 2012 1 3 System Reguirement The new SCB A08 IO box can be installed in Mainconsole v5 0 NVRmini 2 v2 0 NVRsolo v2 0 and Crystal Titan 2 1 or above 1 4 Specification Dimension 1 14mm 143mm 28mm 4 5 i
16. onnection The SCB AO08 is setup in the menu as a TCP or UDP server to us this feature The default setting is 255 255 255 255 It is recommended not to change this setting until the application has been tested and is communicating properly At that point the address filtering feature of the SCB A08 can be activated Suggest use default setting Step 2 Updated server properties separately for each serial port s 13 Trusted Video Management NUUO Surveillance System Accessory 5 3 1 Default Value Model Server Name Password DHCP IP Address Netmesk Gateway MAC Address Baud Rate Data Stop bits Parity Flow Control Protocol Serial Timeout TCP Alive Timeout Connection Mode Delimiter HEX 1 Delimiter HEX 2 Force Transmit TCP UDP port Serial Port Mode Maximum Connection Remote IP Address UL c TCP el NN je IF Trusted Video Management NUUO Surveillance System Accessory 5 4 Web Server Interface The Web Server interface provides the same updating options as Console Mode and Telnet These are located at the bottom of all three Web Server pages If a field is changed you must click Save before leaving that page or the changes will be ignored SCB A08 Web Configuration SCB A08 Note If you leave this page without saving all changes will be ignored xu Server name Suas Serial number Version amp Date 1 8 33 amp 100613 Operation Password DHCP IP address Netmask Gate
17. rough the rest of the setup process Please watt Step 3 Select Next when the SCB A08 Setup window appears Step 4 In the Choose Destination Location window select Next to install the search tool in the default location Select Browse to install into a user selected directory The installation progress will be shown into complete Choose Destination Location Select folder where Setup will install Files Setup will install SCE in the following folder To install to this folder click Next To install to a different folder click Browse and select another folder Destination Folder Ch Program Files 85 MLILICI Browse lt Back Cancel Step 5 Select Finish when the Install Shield Wizard Complete screen appears When the installation is complete the Install window closes allowing the user to access the search tool in the program files Step 6 Connect the SCB A08 to the LAN and the run LED will flash indicating power has been applied and communications with the unit can begin And the Link LED indicates an Ethernet connection has been made 4 2 Updating an Existing Installation If an older version of the search tool is already installed the Modify repair or remove the program window will appear when the installation process is initiated The recommended procedure is to remove all installed components first Once the software has been removed install the new software 12 Trusted Video Management
18. sconnect Suggest use default setting Connection mode The Connection mode field has three options Server Client and Client no heartbeat When Client or Client no heartbeat is selected the Connection at field automatically becomes active allowing the user to select Power up or Data arrival Suggest use default setting e When using the Virtual COM Port feature select Server e When using a TCP or UDP Socket program select Server e When using Paired Mode communication between two serial servers set up one as a Client and the ofher as a Server e When connecting to a server that does not support Heartbeat select Client no heartbeat UID UID Unit Identifier is MODBUS slave address 0x0 0xff It s be defined in MODBUS TCP frame format In Properties We provide consumer define UID Suggest use default setting Delimiter HEX1 and delimiter HEX2 These two fields allow the user to enter two ASCII characters in hex tormat that delimit the beginning and end of a message When a message with both these delimiters is received at the serial port the data contained in the serial buffer is placed in an Ethernet packet and sent out the Ethernet port If only Delimiter 1 is set Delimiter 2 is zero or blank upon receiving Delimiter 1 the SCB AO08 will put all the data in the serial buffer in an Ethernet packet and send it out the Ethernet port If serial data greater than 1 kilobyte is received it will automatically be placed in an
19. way MAC address 4 82 00 08 Link status Hardware ID MODBUS UID Note If you leave this page without saving all changes will be ignored Last update 10 06 2013 18 Trusted Video Management NUUO Surveilance System Accessory 5 5 Upgrading Firmware New firmware may be available at times on www nuuo com Download and may downloaded and flashed to SCB A08 currently in use The user can upgrade using a direct connection to SCB A08 serial port Step 1 Download the new upgrade hex file from www nuuo com gt Download and place in a folder Step 2 Ensure that the DIP switches are all in the OFF position Step 3 Connect a null modem cable between the PC and SCB AO08 Step 4 Open the SCB Manager search tool and select the Firmware Upgrade button Step 5 In the Serial Port selection options select the COM port number used to connect the PC to SCB A08 Step 6 Select Browse find the location of the firmware select Open and then select the upgrade button Upgrade firmware through serial COM port HE File Browse Serial Part Upgrade Cancel Step 7 Software will change upgrade mode and baud rate setting automatically then start upgrade LUME A conected 0 0 0 0 0 estarting Waiting for 5 seconds for the server to restart Step 8 A window showing the Upgrade progress will appear followed by a window indicating the Upgrade was successful Upgrade Step 9
Download Pdf Manuals
Related Search
Related Contents
PELLSTAR Superchips Model 1815 flashpaq Tuner Aide au projet musique 2014-2015 - Le Parc naturel régional de la DecisionTools™ User`s Manual PDF PASSION PRO 1 (Español) DSLR-A100 T'nB ADA4 TYPO3 Online-Marketing 0150-0294A GE Security DVMRe Pro User Manual Philips 32PW8760 32" 100Hz digital scan widescreen TV Copyright © All rights reserved.