1. lt sDATALOGIC S70 Series Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies For complete technical information about this product including dimensions accessories and specifications see Datalogic website Output LED LO DO Switch RUN PRG ADJ Mode Switch Lever Action Fiber Clamp Red Signal Level Green Threshold SET Navigation key Figure 1 WARNING Not to be used for personnel protection Never use this device as a sensing device for personnel protection Doing so could lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energized or de energized sensor output condition Model S70 2 E1 N Single NPN S70 2 E1 P Single PNP S70 5 E1 N Single NPN S70 5 E1 P Single PNP S70 5 E1 PZ complementary outputs S70 5 E2 N Single NPN S70 5 E2 P Single PNP CONNECTIONS NPN Version 10 30 VDC Outputs 18 30 VDC Connector 2 m cable 4 wire Integral M8 Pico QD connector 4 pin Dual outputs 1 push pull IO Link and 1 PNP Integral M8 Pico QD connector 4 pin PNP Version 1 3 4 TOAD 2 L Remote NOTE Open lead wires must be connected to a terminal block 1 A model with a QD connector requires a mating cordset 10 30 VDC Key 1 Brown 2 White 3 Blue 4 Black Programming
2. Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Window SET Note TEACH Selection must be programmed to wind SEt see Program Mode 1 Enter Adjust Mode Method Action Result SET Button Set Mode switch to ADJ RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input 9 No action required sensor is ready for EEE HHH Window SET method 2 SET Sensing Condition Method Action Result e Present sensing condition SET Button e Click the SET Navigation key Threshold Condition Accepted Displays read wind SEt then alternate PASS with Offset Sensor returns to Adjust mode e Present sensing condition Remote Input Single pulse the remote input Threshold Condition Not Accepted Displays read wind SEt then alternate FAIL with minimum Offset for sensing condition Sensor returns to Adjust mode 8 SET Button 0 04 seconds lt Click lt 0 8 seconds g Remote Input 0 04 seconds lt T lt 0 8 seconds 1 gsee Troubleshooting on page 16 for more explanation of the Offset displayed after the Window SET method 9 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC Method Action Result SET Button Move Mode switch to Run RUN PRG ADJ Display Red Signal Level Green Window Center see Figure 5 for instructions on how to display upper and lower thresholds 3 R
3. 24 VDC exclusive of load ECO display mode 720 mW Current consumption lt 30 mA at 24 VDC Supply Protection Circuitry Protected against reverse polarity overvoltage and transient voltages Delay at Power Up 500 milliseconds max outputs do not conduct during this time NPN PNP models 1 current sinking NPN or 1 current sourcing PNP output depending on model Ouput Pent guravon IO Link 1 push pull and 1 PNP complementary outputs 100 mA max load derate 1 mA per C above 30 C Output Rating OFF state leakage current NPN PNP models lt 5 pA at 30 VDC i ON state saturation voltage NPN lt 1 5 V PNP 1O Link lt 2 V po lOlink lt 50pAat30VDC e OutputProtection Protected against output short circuit continuous overload transient over voltages and false pulse on power up Super High Speed 10 us High Speed 200 us High Speed 15 us Standard 500 us Fast 50 us Long Range 2 ms Standard 250 us Extra Long Range 5 ms Medium Range 500 us Long Range 1000 us Super High Speed 5 us High Speed 5 us Fast 12 us Standard 50 us Medium Range 80 us Long Range 165 us ee Black ABS Polycarbonate alloy UL94 V 0 rated Construction housing clear polycarbonate cover Environmental Rating IEC IP50 NEMA 1 Operating Temperature 10 C 55 C Storage Temperature 20 C 85 C Humidity 90 at 60 C maximum relative humidity non condensing Supports Smart Sensor Profile Yes Baud Rat
4. N O Pico Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net wDATALOGIC MOUNTING INSTRUCTIONS Mount on a DIN Rail 1 Hook the DIN rail clip on the bottom of the S70 over the edge of the DIN rail 1 2 Push the S70 up on the DIN rail 1 3 Pivot the S70 onto the DIN rail pressing until it snaps into place 2 Remove from a DIN rail 1 Push the S70 up on the DIN rail 1 2 Pivot the S70 away from the DIN rail and remove it 2 INSTALLING THE FIBERS Follow these steps to install glass or plastic fibers Move forward to release the fibers 1 Open the dust cover Fiber Clamp 2 Move the fiber clamp forward to unlock it Fiber Receiver Port 3 Insert the fiber s into the fiber port s until they stop 4 Move the fiber clamp backward to lock the fiber s FEEF emenort 5 Close the dust cover Fiber Adapters NOTE If a thin fiber with less than 2 2 mm outer diameter is used install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Datalogic includes the adapters with all fiber assemblies TO Ni Fiber Outer Diameter mm Adapter Color aa Black Red No adapter needed 3 TO SENSOR When connecting coaxial type fiber assemblies to the amplifier install the solid core fiber to the LED emitting port and the multi core fiber to the PD receiving port for most reliable detection RECEIVE
5. minimum very stable operation Percent Offset after SET The Window Dark and Light SET methods will flash a offset on the displays after a PASS or FAIL SET Result Offset Meaning PASS with Offset Displays the offset used for the SET method FAIL with Offset Displays the minimum required offset necessary to PASS the SET method FAIL without Offset Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination changes in the taught condition can prevent the Auto Thresholds algorithm from optimizing the threshold s Display Description Corrective Action Threshold Alert Alternates The threshold s cannot be Cleaning correcting the sensing optimized but the sensor s output environment and or a re teach of the will still continue to function sensor is highly recommended Threshold Error The threshold s cannot be Cleaning correcting the sensing optimized and the sensor s output environment and or a re teach of the will stop functioning sensor is required 16 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC TECHNICAL DATA S70 x E1 S70 x E2 660 nm visible red 635 nm visible red Snbin Voltage NPN PNP models 10 30 VDC Class 2 10 max ripple PPly ge IO Link models 18 30 V dc 10 max ripple Power and Current Consumption Standard display mode 960 mW Current consumption lt 40 mA at
6. J Display Red Signal Level Green Threshold Remote Input No action required sensor returns to RUN HH ee mode automatically 15 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net w DATALOGIC IO Link Interface IO Link is a point to point communication link between a master device and sensor It can be used to automatically parameterize sensors and transmit process data For the latest IO Link protocol and specifications please visit the web site The IO Link IODD package is available on the Datalogic Website Troubleshooting Manual Adjustments Disabled Manual adjustments are disabled when Auto Thresholds are ON If a manual adjustment is attempted while Auto Thresholds are ON the Green display will flash BE Percent Minimum Difference after TEACH The Two Point and Dynamic TEACH methods will flash a minimum difference on the displays after a PASS or FAIL Value PASS FAIL Description 0 to 99 FAIL The difference of the taught conditions does not meet the required minimum 100 to 300 PASS The difference of the taught conditions just meets exceeds the required minimum minor sensing variables may affect sensing reliability 300 to 600 PASS The difference of the taught conditions sufficiently exceeds the required minimum minor sensing variables will not affect sensing reliability 600 PASS The difference of the taught conditions greatly exceeds the required
7. M MODE Mode Switch to PRG Menu List Press and hold SET to exit choice list without saving RUN PRG ADJ Click SET to enter choice list DISPLAY ar a dYn tcH Lt SEt CAL SEt Click SET to enter choice list M DISPLAY ma LOOP for the value see Technical Data pag 17 Click SET to enter choice list ME to set value 999 Pct L to enter choice list P 4 gt Navigation key Click SET v DISPLAY _ LOOP Click SET to enter choice Vv To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a choice list without saving Press and hold SET for 2 seconds 4 orf 4 to set value Click SET to enter choice list g orf 4 to set value to enter choice list Click SET g or 4 to set value Click SET to enter choice list Vv 4 or 4 to set value diSP rEAd Click SET to enter choice list op DISPLAY m LOOP display flips 180 Click SET to enter choice list v p DISPLAY mm LOOP Fixed Gain Set Click SET to enter choice list v CBs yES Click SET to select and save a choice in any list Return to Menu List 70 E1 Factory Default Settings Factory Default Two Poin
8. R Multi core fiber EMITTER Single core fiber ron Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net w DATALOGIC TOP PANEL INTERFACE Opening the dust cover provides access to the top panel interface The top panel interface consists of the RUN PRG ADJ mode switch LO DO switch SET Navigation key dual red green digital displays and output LED RUN PRG ADJ Mode Switch RUN PRG ADJ 3 The RUN PRG ADJ mode switch puts the sensor in RUN PRG Program or ADJ Adjust mode RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the SET button PRG mode allows the sensor to be programmed through the display driven programming menu see Program Mode below ADJ mode allows the user to perform Expert TEACH SET methods and Manual Adjust see Adjust Mode below LO DO Switch LO DO Ps The LO DO switch is used to select Light Operate or Dark Operate mode In Light Operate mode the output is ON when the sensing condition is above the threshold for Window SET the output is ON when the sensing condition is inside the window In Dark Operate mode the output is ON when the sensing condition is below the threshold for Window SET the output is ON when the sensing condition is outside the window SET Navigation key 4 The SET Navigation key is a 3 way button The positions are engaged by rocking the button lef
9. e 38 400 bps COM2 Process Data Width 16 bits IODD files Provide all programming options of top panel interface plus additional functionality CE Certifications LISTED 10 Link a Output Response Time High Speed 66 us Repeatability Standard Long Range 100 us Extra Long Range 100 us 10 Link Interface 17 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC OVERALL DIMENSIONS CABLE VERSION i n l i 1 l CONNECTOR VERSION E i l T l l T Dimensions in mm DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification 821002591 Rev A 161275C 177900B Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net
10. ee Fig 2 Darkest Taught Lightest Taught Condition Condition Sensor positions threshold midway between taught conditions Output OFF Output ON lt gt Darkest Position Most Light no signal adjusted by saturated Manual Adjust signal Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can be reversed by using the LO DO Light Operate Dark Operate switch see LO DO Switch in Top Panel Interface Two Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments e Slide Mode switch to ADJ to enter Adjust mode e Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Two Point TEACH NOTE TEACH Selection must be programmed to 2Pt tcH see Program Mode 1 Enter Adjust mode Method Action Result 2 Set the Mode switch to ADJ RUN PRG ADJ Display Red Signal Level SET Button Green Threshold Remote Input 3 No action is required sensor is ready for EE EEEH the Two Point TEACH method 2 SET Button 0 04 seconds lt Click lt 0 8 seconds 3 Remote Input 0 04 seconds lt T lt 0 8 seconds Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Ema
11. enter Adjust mode e Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation Remember Auto Thresholding is automatically disabled in Calibration SET Follow these steps to perform a Calibration SET Note TEACH Selection must be programmed to CAL SEt see Program Mode 1 Enter Adjust Mode Method Action Result SET Button 17 s i RUN PRG ADJ SEEMOUS SWEA IT ADY Display Red Signal Level Green Threshold Remote Input 18 No action required sensor is ready for EEL EEEH Calibration SET method 17 SET Button 0 04 seconds lt Click lt 0 8 seconds 18 Remote Input 0 04 seconds lt T lt 0 8 seconds 14 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net wDATALOGIC 2 SET Sensing Condition Method Action Result e Present sensing condition RUN PRG ADJ a SET Button Click the SET Navigation key ao Condition Accepted Displays read CAL SEt then flashes PASS Sensor returns to Adjust mode e Present sensing condition T Remote Input Single pulse the remote input Threshold Condition Unacceptable Displays read CAL SEt then flashes FAIL Sensor returns to Adjust mode 1 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN RUN PRG AD
12. eturn to RUN Mode Remote Input No action required sensor returns to Run mode automatically Ee HHH Window SET during RUN mode Upon sensor power up Window Center is displayed 234 Uthr 234 Lthr i i A v 1234 2200 1234 2000 1234 1800 Upper Window Lower Threshold Center Threshold Displayed Displayed Displayed Figure 5 Upper and Lower Thresholds 10 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC e Sets a threshold a programmable offset below the presented condition e Changes output state on any condition darker than the threshold condition e Threshold can be adjusted using and Navigation key Manual Adjust e Recommended for applications where only one condition is known for example a stable light background with varying darker targets e See Program Mode for programming the Offset Percent setting A single sensing condition is presented and the sensor positions a threshold a programmable offset below the presented condition When a condition darker than the threshold is sensed the output either turns ON or OFF depending on the LO DO switch setting see LO DO Switch in Top Panel Interface Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset below the lt q presented condition Output OFF Output ON Darkest Condition Most Light
13. g condition Sensor returns to Adjust mode 3 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input No action required sensor returns to RUN Bo Be mode automatically 14 SET Button 0 04 seconds lt Click lt 0 8 seconds 15 Remote Input 0 04 seconds lt T lt 0 8 seconds 16Sce Troubleshooting on page 16 for more explanation of the Offset displayed after the Dark SET method 13 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC Calibration SET e Sets a threshold exactly at the presented condition e Threshold can be adjusted using and Navigation key Manual Adjust A single sensing condition is presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO switch setting see LO DO Switch in Top Panel Interface Threshold position adjusted by Manual Adjust C S E Sensor positions threshold exactly at the presented condition gt Output OFF Output ON Darkest Condition Most Light no signal Presented saturated signal Figure 8 Calibration SET Light Operate shown Calibration SET and Manual Adjust Moves switching threshold value up or down to make adjustments e Slide Mode switch to ADJ to
14. il info ctiautomation net DATALOGIC 2 Teach the first condition Method SET Button Action a Present the first condition b Click the SET Navigation key Result Display Flashes 2Pt tch then holds on 1234 2nd a Present the first condition b Single pulse the remote input Remote Input 3 Teach the second condition Method Action Result SET Button a Present the second condition 4 TEACH Accepted b Click the SET Navigation key l Displays alternate PASS and Minimum Difference Sensor returns to Adjust mode Remote Input a Present the second condition b Single pulse the remote input TEACH Not Accepted Displays alternate FAIL and Minimum Difference Sensor returns to Adjust mode 4 Return to Run mode Method Action Result SET Button Move the Mode switch to RUN Display Red Signal Level Green Threshold RUN PRG ADJ Remote Input No action is required sensor returns to RUN mode automatically Dynamic TEACH e Teaches on the fly e Establishes a single switching threshold e Threshold can be adjusted using and Navigation key Manual Adjust Dynamic TEACH is best used when a machine or process may not be stopped for teaching The sensor learns during actual sensing conditions taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level see Fig 3 Darkest Taught Condition Lightest Taught Cond
15. ition Sensor positions threshold midway between taught conditions Output OFF Output ON Darkest bcs Most Light no signal adjusted By saturated Manual Adjust signal Figure 3 Dynamic TEACH Light Operate shown The output ON and OFF conditions can be reversed using the LO DO switch see LO DO Switch in Top Panel Interface 4 See Troubleshooting on page 16 for more explanation of the Minimum Difference displayed after the Two Point TEACH method Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC Dynamic TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments e Slide Mode switch to ADJ to enter Adjust mode e Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dynamic TEACH NOTE TEACH Selection must be programmed to dYn tcH see Program Mode 1 Enter Adjust Mode Method Action Result SET Button gt Set Mode switch to ADJ RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input 6 No action required sensor is ready for EEE EPH Dynamic TEACH method 2 Enter Dynamic TEACH Method Action Result SET Button Click
16. ndition Not Accepted Displays read Lt SEt then alternate FAIL with minimum Offset for sensing condition Sensor returns to Adjust mode 3 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input No action required sensor returns to RUN mode automatically Dark SET e Sets a threshold a programmable offset above the presented condition e Any condition lighter than the threshold condition causes the output to change state e Threshold can be adjusted using and Navigation key Manual Adjust e Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets e See Program Mode for programming the Offset Percent setting NOTE Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal 0 counts A single sensing condition is presented and the sensor positions a threshold a programmable offset above the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO switch setting see LO DO Switch in Top Panel Interface Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset above the presented condition Output OFF Output ON Darkest Condition Most Light no signal Presented saturated signal Fig
17. no signal Presented saturated signal Figure 6 Light SET Light Operate shown Light SET and Manual Adjust Moves switching threshold value up or down to make adjustments e Slide Mode switch to ADJ to enter Adjust mode e Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Light SET Note TEACH Selection must be programmed to Lt SEt see Program Mode 1 Enter Adjust Mode Method Action Result SET Button H Set Mode switch to ADJ RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input 12 No action is required sensor is ready for Light SET method 11 SET Button 0 04 seconds lt Click lt 0 8 seconds 12 Remote Input 0 04 seconds lt T lt 0 8 seconds 11 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC 2 SET Sensing Condition Method Action Result e Present sensing condition SET Button iti x Glickihe SET Navigation key RUN PRG ADJ Threshold Condition Accepted Displays read Lt SEt then alternate PASS with Offset 3 Sensor returns to Adjust mode e Present sensing condition T Remote Input e Single pulse the remote input U Threshold Co
18. t right iy The SET position is engaged by clicking down the button while the rocker is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET is used to perform TEACH SET methods and are used to manually adjust the threshold s The Navigation key is disabled during RUN mode except when using Window SET see HEE HEET Window SET Red Green Digital Displays During RUN and ADJ mode the Red display shows the signal level and the Green display shows the threshold During PRG mode both displays are used to navigate the display driven programming menu Output LED The output LED provides a visible indication when the output is activated Remote Input IO Link For more information about how to perform TEACH SET methods to program the sensor remotely or to interface with the sensor via IO Link see the Datalogic website Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes The SET Navigation key is disabled during RUN mode except when using Window SET see Window SET Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net wJATALOGIC gt a lt x ie a a ow Program Mode Program PRG mode allows the following settings to be programmed in the S70 Phone 800 894 0412 Fax 888 723 4773 Web PROGRA
19. t TEACH c o 2 N pa Threshold Standard 500 us OFF Response Speed Auto Thresholds Offset Percent 0 Disabled OFF Delay 0 Disabled OFF One Shot 0 Disabled 0 Disabled ON One Shot Numeric ECO Display Readout disabled Normal Orientation x on display represents a w Auto Gain Gain Selection S70 E2 Factory Default Settings Factory Default Threshold Two Point TEACH Cc 2 E w N le z H Standard 250 us Response Speed al on display represents a m Offset Percent OFF Auto Thresholds 0 Disabled OFF Delay www ctiautomation net Email 0 Disabled 0 Disabled 0 Disabled Numeric ECO OFF One Shot ON One Shot Display Readout disabled Normal Orientation Auto Gain Gain Selection info ctiautomation net DATALOGIC ADJUST MODE Sliding the RUN PRG ADJ mode switch to the ADJ position allows the user to perform Expert TEACH SET methods and Manual Adjustment of the threshold s Two Point TEACH e Establishes a single switching threshold e Threshold can be adjusted using and Navigation key Manual Adjust Two Point TEACH is used when two conditions can be presented statically to the sensor The sensor locates a single sensing threshold the switch point midway between the two taught conditions with the Output ON condition on one side and the Output OFF condition on the other s
20. the SET Navigation key Display Flashes dYn tch then holds on 1234 dYn T Remote Input Single pulse remote input 3 Present ON and OFF Conditions Method Action Result Display Red Signal Level SET Button Present ON and OFF conditions Green Threshold Remote Input Present ON and OFF conditions EEL eo ug 5 SET Button 0 04 seconds lt Click lt 0 8 seconds 6 Remote Input 0 04 seconds lt T lt 0 8 seconds Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net wDATALOGIC 4 Exit Dynamic TEACH Method Action Result SET Button Click the SET Navigation key L TEACH Accepted Displays alternate PASS with T Minimum Difference Sensor returns to Adjust mode Remote Input Single pulse remote input LI TEACH Not Accepted Displays alternate FAIL with Minimum Difference Sensor returns to Adjust mode 5 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input No action required sensor returns to RUN mode automatically Window SET e Sets window thresholds that extend a programmable offset above and below the presented condition e All other conditions lighter or darker cause the output to change state e Sensing window center can be adjusted using and Navigation key Manual Adjust e Recommended for applications where a product may not alwa
21. ure 7 Dark SET Light Operate shown 13See Troubleshooting for more explanation of the Offset displayed after the Light SET method 12 Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net DATALOGIC Moves switching threshold value up or down to make adjustments e Slide Mode switch to ADJ to enter Adjust mode e Press to increase press to decrease eGREEN display shows the switching threshold value o2 seconds after adjustment the GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dark SET Note TEACH Selection must be programmed to dr SEt see Program Mode 1 Enter Adjust Mode Method Action Result SET Button 14 Set Mode switch to ADJ RUN PRG ADJ Display Red Signal Level Green Threshold Remote Input 15 No action required sensor is ready for Dark SET method 2 SET Sensing Condition Method Action Result e Present sensing condition SET Button e Click the SET Navigation key Threshold Condition Accepted Displays read dr SEt then alternate PASS with Offset 4 Sensor returns to Adjust mode e Present sensing condition a PRSS Remote Input Single pulse the remote input Threshold Condition Not Accepted Displays read dr SEt then alternate FAIL with minimum Offset for sensin
22. ys appear in the same place or when other signals may appear e See Program Mode in the user s manual for programming the Offset Percent setting to increase decrease the window size A single sensing condition is presented and the sensor positions window thresholds a programmable offset above and below the presented condition In LO mode Window SET designates a sensing window with the Output ON condition inside the window and the Output OFF conditions outside the window see Fig 4 Sensing window center adjusted by Manual Adjust Sensor positions window thresholds aprogrammable offset from the presented condition Output ON Darkest Condition Most Light no signal Presented saturated signal Figure 4 Window SET Light Operate shown Output ON and OFF conditions can be reversed using the LO DO switch see LO DO Switch in Top Panel Interface 7 See Troubleshooting on page 16 for more explanation of the Minimum difference displayed after the Dynamic TEACH method Phone 800 894 0412 Fax 888 723 4773 Web www ctiautomation net Email info ctiautomation net w DATALOGIC Moves sensing window center value up or down to make adjustments e Slide Mode switch to ADJ to enter Adjust mode e Press to increase press to decrease GREEN display shows the sensing window center value 2 seconds after adjustment the GREEN display will flash 3 times to confirm e Slide Mode switch to RUN to complete operation