1. CLIMATIC 30 USER MANUAL PROVIDING gt gu COMFORT v LENNOX gt CHILLERS LENNOX PARAM MANAGER SOFTWARE USER MANUAL INTRODUCTION 2 MINIMUM SYSTEM REQUIREMENTS 3 ELECTRICAL CONNEXIONS croceo ee 4 Lii BI 5 TABLE DISPLAY DESCRIPTION as 7 CONNEXION CLIMATIC 30 5 8 CONNEXION TO CLIMATIC 30 IMPORT EXPORT FILES 10 ete 12 LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt INTRODUCTION Param Manager is composed of configuration software for PC that can be used to Read a parameters configuration or part of it from a CLIMATIC 30 e Write a parameters configuration or part of it on a CLIMATIC 30 e Verify a parameters configuration or part of it with a CLIMATIC 30 e Perform the above operations starting from previously stored files or from a purposely created parameters list stored in the PC memory manual input e Manipulate parameters files related to CLIMATIC 30 with or without protection code that controls parameters accessibility from the keyboard and through password e Chec
2. LENNOX gt MAIN PANEL The main panel is shown at program start up It permits to access all available functions The upper part of the application window shows program name name of the selected model and name of the file in memory E PARAMETERS TABLE 1 Index Description Unit Protection 1 Machine configuration 0 3 770 2 Dealing zeipiii Cn 51 T 150 3 3 Healing setpoir 100 600 300 3 4 4 Cooling hysteresyg C 0 120 20 2 5 5 Heating CO 0 126 20 3 Min cool fan speed selpon C 0 126 20 258 Max cod fan speed selpoint C ber 125 30 258 8 fan speed E bar 0 128 15 256 a 9 heat Tan xsetnnint 175 5 Jar 11 23 2303 39 A special Excel compatible control is opened inside the main panel it represents the general parameters list shown in the table display As an alternative choice the parameters be manipulated through the graphical approach eased by the object display In both display modes and generally in other program screens all the main panel controls reported in the next table are active Menu Activation Buttons or Used to keycombinations generate a default map based on the model create an empty map to which no parameter belongs based on the model Load a map from disk invokes the Windows standard dialogue File Default File Empty File
3. Query the on line help related to the program or model 2 Iinfo Invoke the program general information box program name version date etc Enable the graphical print hard copy of the active window Switch to the CLIMATIC 30 connection window display Connection with the CLIMATIC 30 Require an automatic correction of errors violation of local and global rules on the map in use enabled when the map in use is complete only Input or modify the values and protection codes of parameters table parameters in the related cells unique and alternative to the Object functions window Input or modify the values and protection codes of parameters by operating on graphical controls and Objects functions accessing them according to the groupings represented by objects and functions unique and alternative to the Parameters table The following icons are shown on the upper right They indicate respectively e State of connection with the serial port COM e Presence and state of the hardware key KEY e Correctness of the CLIMATIC 30 address ADD e Recognition of the CLIMATIC 30 type DEV If one of the previous icons is crossed the communication with the CLIMATIC 30 cannot take place If the communication is correct the information on the number of the active serial port is reported COM1 2 Double clicking on one of the active icons enables the CLIMATIC 30 self recognition proces
4. Selected 2 HA came CR el EE button to Denon C Search Apply Print 2 ts Then it is possible to compare file you want to load in the CLIMATIC 30 and the file which is already in by following the procedure hereunder Device manipulation optione Activate All and verify C Load from device White bo device and click on Load from device C 147 Parameters Veri Selected Param manager will upload the program and compare it with the file opened previously The number of differences will be displayed And the lines with differences will be written in red In the column Value you will see the value of the opened file and in the column device you will find the value in the device is also possible to download the opened file into the CLIMATIC 30 by following the procedure hereunder Device manipulation options Activate All and deactivate verify Load device Write to device and click on 147 Parameters Ve Selected Obviously it is possible to download only some parameters LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt PRINT The Print window permits to configure print operations by defining e Name of the map s author e Map title e Print date and time e name of the file related to the map e name of the model the map refers to e logo t
5. Open save a map to disk if a name has already been assigned File Save save map to disk with a specific name invokes Windows au none import a map from the dbf format used by the older generation param exe DOS program Export the in use to the dbf format used by the older generation param exe DOS program additional data used by Param Manager only are not saved Change the model i e the family of products whose maps shall be processed by selecting among installed model language combinations File Print the print of the parameters list or a selected part File Exit ALT F4 Exit the program Modify Cancel Cancel the last change made in a parameter value or protection Switch to table display enabled in object display mode only Switch to object display enabled in table display only and when the map in use is complete File Import File Export File Change model Actions Show table E Actions Show objects LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOXD Actions Connection with the CLIMATIC S 30 Input user notes related to the map in use shown Actions Input notes reports on the print report Modify the program language by selecting another one AIN among the installed languages available from anguage submenu
6. REQUIREMENTS INSTALLATION Operating system Windows 3 x 16 bits or Windows 95 and over 32 bits Processor Pentium 133 RAM 16Mbytes or more Graphical resolution VGA minimum 800x600 256 colours recommended or more Required Hard Disk space the hard disk space required can be thus summarised e Program 10Mb e Program Help 5Mb for each language installed e Model 100k for each model including all languages e Model Help 3Mb for every language The minimum configuration 1 language 4models requires approximately 30 Mb Peripherals Keyboard Mouse or equivalent pointing device printer optional Installation The installation shall be executed after all active Windows programs Office applications Internet navigation programs etc have been closed including programs automatically executed at startup such as the Microsoft Office Bar electronic mail managers resident anti virus programs etc to prevent such applications from exclusively book the access to shared system libraries required for the installation To install the product Start the installation program setup exe for all versions e Select the operating system Windows 3 11 16 bits or Windows 95 and over 32 bits e Select the language for the installation program e Now the user shall proceed according to the instructions on video The installation program permits to e Select the language for the installation program e Select the inst
7. 04
8. allation path for the PARAM MANAGER program e Select the language for the PARAM MANAGER program e Select the models families of products required and the related language The installation program can also e add remove components to install already installed At least one CLIMATIC 30 model shall be installed to permit the program to operate correctly LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English 2 ELECTRICAL CONNEXIONS The communication between the PC and the CLIMATIC 30 requires the serial communication key EWTK PT 4 DIN modules shall be connected as shown in the picture serial connector ar RSS TTL TTL connection ar 5485 5485 T SERIAL A A CONNECTION i KEY PERSONAL COMPUTER Connections between the PC and the key and between the key and the CLIMATIC 30 shall be carried out without voltage on every CLIMATIC 30 and in compliance with safety regulations in force Electrostatic shocks shall be avoided particularly on visible metal parts of CLIMATIC 30 Check the electrostatic currents are free to flow to ground by means of suitable solutions The connection of the CLIMATIC 30 to the serial communication key is not required during installation nor while manipulating the parameters files LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English
9. des the parameters read by the CLIMATIC 30 while the previous column the 2 previous columns if a protection code is present represents the contents of the memory map in memory or a file total or partial amp Geral link with device Description Lind Min Max Value Protection Device Device EA MES G02 Hesting 300 600 452 G c Passvword m 0 255 selpoint in pestina 450 990 HO2 Min setpoint in heating 400 450 200 in coolina E 100 900 qoo HO4 Min setpoint in cooling E 4 100 0 Has 11 contiquraton HNIS gt T2 configuration 2 1 HO ST3 configuration E 0 1 contguralion 1 LO Ch Cu 151 53 443 GR LJ co 4 Device manipulation options Se al poit Link Load fiom device Write to device Com Parameter 5 pa 147 Yen Seidpoti 0 0 7 Selected memo C file Seach Apply buton tn memor C 15 Seach controls summarised in the following table are active Display the results of read write operations or comparisons between Parameters list Excel sheet memory files and CLIMATIC 30 the column referring to non editable protection codes are only present if the selected model provides for a protection can be selected by full rows Select the group of data to operate on enabled indicates the whole lis
10. e x Annuler Active parameters 0204 Open a DAT file Once the right file is chosen you will have to choose Overwrite all e x a al kel n E Description Min Max Value Protection DAT file load options 2 The reference model is compatible with the one in use The file C Documents and Settings FPELLET Bureau Climatic 30 en contains 204 parameters on total of 204 One or more datas in the file are different from the ones in memory Overwrite all Interactive Active parameters 0 204 a DAT Once the 30 is connected you can start the communication by clicking on gt You will get the following page LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt Serial link with device Device Device Description value Protection GUN PES ES CE 00 G02 Heating BOO 3 G c Passvword i 255 3 HUN in pestina 990 a HO2 Min setpoint in beating 450 3 5 zetpoint in caning a 900 3 HO4 Min selpoirk cooling 100 3 11 cantiquratian 3 3 a HNIS gt T2 configuration 1 3j HO ST3 configuration 0 5 3 10 HIS gt T4 configuration 3 Device manipulation option Senal port Link Load from device Write bo device Com Parameter NUN Pitan Serial port 7 Bl
11. er manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX 50 manual tor Param Manager sofware for communication with CLIMATIC 30 1044 amp 12 ENNO www lennoxeurope com BELGIUM LENNOX BENELUX N V S A LUXEMBOURG www lennoxbelgium com CZECH REPUBLIC LENNOX JANKA a s www janka cz FRANCE LENNOX FRANCE www lennoxfrance com GERMANY LENNOX DEUTSCHLAND GmbH www lennoxdeutschland com IRELAND LENNOX IRELAND www lennoxireland com NETHERLANDS LENNOX BENELUX B V www lennoxnederland com POLAND LENNOX POLSKA z o o www lennoxpolska com PORTUGAL LENNOX PORTUGAL Lda www lennoxportugal com RUSSIA LENNOX DISTRIBUTION MOSCOW www lennoxrussia com SLOVAKIA LENNOX SLOVENSKO s r o a 2 e REA www lennoxdistribution com 2 5 www lennox refac com UKRAINE LENNOX DISTRIBUTION KIEV www lennoxrussia com UNITED KINGDOM LENNOX UK www lennoxuk com OTHER COUNTRIES LENNOX DISTRIBUTION www lennoxdistribution com PARAM MAN Due to Lennox s ongoing commitment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability CL30 CH LLERS Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installation and service must be performed by a qualified installer and servicing agency 10 10
12. ion for the Apply operation Indicates the source or destination file with its path to be used in case the to file option is selected from the previous control the source file name is prompted by default Browse button Select the destination among the existing files Serial Port Select the serial port for dialogue with the CLIMATIC 30 indicate the serial port in use for the dialogue with the CLIMATIC 30 Indicate the state of an internal E2 it is not present if the model doesn t indicate its presence when red writing is ignored E2 protected when yellow writing is allowed until the next line power down self protection being enabled when green writing is permitted E2 not protected Disable the protection of the internal E2 or if already disabled re initialise the self protection timeout when provided otherwise once the E2 has been unprotected the key is disabled indicate the index of the parameter being processed the index moves through the list of selected parameters Apply button Destination File text box indicate the progress referred to the total number of operations includes an internal text that shows the phase in progress read write verify activate etc indicate data transfer from PC to CLIMATICTM 30 and vice versa is in progress indicate the global results of the comparison number of detected discrepancies 2 counters for values and protection codes Interrupt the read
13. k the set values for single parameters do not exceed the minimum and maximum limits and restrictions due to the interaction with other parameters e Check the list of values set for parameters complies with special typical configurations Basic concepts Basically the program allows to manipulate the variable settings of a CLIMATIC 30 typically the parameters The program user is provided a table approach that allows to manipulate parameters values and protections by directly accessing their complete list with a suitable graphical interface Moreover Param Manager provides a range of other generic utility functions e possibility to work with partial files i e with incomplete list of parameters e possibility to save the customised parameters lists in single files to upload modify or use them later e possibility to configure the communication modes with the CLIMATIC 30 through a special control panel that permits the selection of the PC serial port the origin file names for download or destination for parameters upload e Possibility to upload files from the CLIMATIC 30 and compare it to other files e possibility to print complete or partial lists of parameters by arranging special customisations of the print report through a special control panel and to print the active window LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt MINIMUM SYSTEM
14. o be applied on the upper left corner of the print e notes related to the map file It also permits to select whether the print shall be limited to previously selected elements only or extended to the whole enabled map only parameters whose value and or protection Author code was input Usually data printed F Heading PARAMETERS TABLE portrait A4 format with pre set layout A print preview can be displayed Date and hour 23 03 33 11 26 00 4 Fle name NOMAME Notes related to the map can be input from I Model menu selection Actions Input notes report of the main window the available space in the Iv Logo Search print report limits the maximum length of v Notes Notes message to about 4 lines in the A4 portrait format 9 All the parameters Graphic print The contents of the video active window can be printed by pressing button Printer Preview Close Rapid print from panel connection with the CLIMATIC 30 The rapid print can be started directly from the Connection with the CLIMATIC 30 window to examine the result of a comparison between maps total or partial besides checking results on video This function prints a report including references only map in memory or on file with CLIMATIC 30 and file names with model name and the contents of the same comparison table shown in the Connection with the CLIMATIC 30 window s
15. s LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt TABLE DISPLAY DESCRIPTION Goals Enabling this mode means to display an Excel compatible sheet in the main window The sheet is thus organised N is the maximum permitted parameter index for the selected model Sa Ste ee ee nce REST ESSEN Parameter edi Min 1 Parameter desorption 1 Un amp 1 E 3 Parameter gesenton 3 Unt 2 PaO Pad Prot Fa02 RT Parameter desenptisn n Una The cell data assume different colours according to the meaning Table Use The user can e Input or modify the values to assign to parameters in column F according to the same modes available in Microsoft Excel the input of a value in a shadowed row indicates the corresponding model parameter is declared as present in the list of those belonging to the map in use double click on the row using the right button to enable the default value e Input or modify protection codes accessibility changeability of each parameter in column G such column is only present if the selected model allows the use of a protection code e Delete a parameter from the list or o disable it to create a partial list by double clicking on the row using the mouse right button such operation shadows the ro
16. t of active parameters listed indicates the list of parameters previously selected from the Objects Functions window the option is disabled if no pre selection is present selected indicates the group of parameters selected in the list above Listed enabled selected options LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English HN LENNOX gt Select whether data read from a CLIMATIC 30 Read from CLIMATIC 30 shall be stored in the internal memory Memory file options CLIMATIC 30 Value column or file Select whether data from internal memory Value column or from file shall be written to a CLIMATIC 30 Write to CLIMATIC 30 Source destination File text Indicates the source or destination file with its path to be used in box case the file option is selected from the previous control Browse Button Select the source or destination file among the existing Read from device button Enable parameters load from CLIMATIC 30 according to the selection writing CLIMATIC 30 according to Check option Perform a data check after write operations Copy selected data of the CLIMATIC 30 Value column and CLIMATIC 30 Protection to the Value column Protection if the memory option is selected or to file if the file option is enabled Spo Select the destinat
17. w contents i e a parameter cannot be deleted from the model but only from the parameters map in use e Display the violated rules by double clicking with the mouse left button on the value cells column F that contain invalid data parameter value violating the local or global rules or a protection code not corresponding to a permitted combination of visibility changeability in the 1st 2nd menu The error is highlighted in red and in boldface Every parameter activation or change determines the automatic procedure for value control LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt CONNEXION TO CLIMATIC 30 SUMMARY By default the Connection with the CLIMATIC 30 window prompts the list of parameters selected before access However it is possible to operate on the whole active map or on a subgroup of the displayed list without the need to make a pre selection The user can display the contents of the memory or a file total or partial dat so as to compare it with the corresponding parameters on the CLIMATIC 30 The parameters or part of them detected by reading a CLIMATIC 30 can be saved to memory or file Data in memory or stored in a file even selecting a part of it can be written to the CLIMATIC 30 Other commands are available to set the dialogue modes The last column in the parameters list the last two if a protection code is present inclu
18. write operations in progress Invoke the Rapid print window to print the contents of the parameters list above Close button ESC Close the connection with the CLIMATIC M 30 window Discrepancies during the phases of comparison between memory or file and CLIMATIC 30 are signalled by displaying involved data value protection code in red and boldface Errors in communication with the CLIMATIC 30 are highlighted in a special message the read write operation is then cancelled this can also be done by pressing the Stop button The total number of errors or a status message e g OK is reported inside the progress bar LENNOX User manual for Param Manager software for communication with CLIMATIC 30 10 04 English LENNOX gt CONNEXION CLIMATIC 30 IMPORT EXPORT FILES While opening Param manager the program will display the default table In order to download the right program to the CLIMATIC 30 it is necessary to load it from the program file list xxx dat files a 2 8 147 Regarder dans Climatic 30 en ligne J WA44STD DAT JRA3STD DAT Mes documents RAS DAT JRASSTD DAT JRA6 DAT X RA6STD DAT 3 RA44 DAT RA44STD DAT x WAS3 DAT Mes documents G WA4 DAT 53 WA4STD DAT 4 8 a WAS DAT ES WASSTD DAT WA44 DAT Poste de travail 2 Favoris r seau Nom du fichier RA3S vj Fichiers de typ