SingleNet – User Manual Application version: • PoleNET: V1.18

image

Contents

1. Simply click the Connect button again to reconnect Testing the system for proper operation This section describes how to test the system NMC 64 PRO SingleNet system for proper operation This can only be done after installation is complete and all settings are believed to be correct 12 Make sure that all units are connected and in operative mode 13 If possible connect a PC to the 2 Wire host and open the PoleNet software see sections Connecting 2 Wire host to PC Selecting the System to Connect to and Connecting to a System 14 Open the PoleNet Two Wire Monitor screen 15 Enter the NMC 64 PRO Test menu menu 5 Test 16 Enter the NMC 64 PRO Test Relays menu menu 5 1 Relays 17 Select an output relay configured to the SingleNet system and set it to Man 18 Wait between 10 to 30 seconds to see whether the RTU output is physically turned On and the output status changes to On in the PoleNet Two Wire Monitor screen 33 NMC 64 PRO Irrigation NETAFIM An installation is completed if everything works properly If not you can try the following e Manually turning an output On through the PoleNet software see section Monitoring 2 Wire Systems Test mode If the output is turned On through the PoleNet software try rechecking your configuration definitions in the PoleNet e Check valve connection as mentioned above the output does not turn On if not connected to a valve e Verify software versions
2. must be set to ensure reliable communications are possible at all times with all RTUs The unique characteristics of each installation imposes a lower limit on the bit width and this in turn sets an upper limit on the Comms Slots value Clear Inputs after RTUs absent for a number of minutes PoleNet V1 21 onwards This setting is also only available for two wire hosts from version 1 28 onwards so it is greyed out if earlier version two wire hosts are used Old versions of the two wire host prior to version 1 28 always report the last known state of the inputs from RTUs even if any RTUs become lost or are out of communication for a very long time This new setting will clear the two wire host s copy of the inputs from any RTU after the RTU has been absent unable to be contacted for long periods of time up to 1 hour This is generally preferable and safer than assuming that the inputs are still active 25 NMC 64 PRO Irrigation N NETAFIM Stagger Outputs Delay between valves opening PoleNet V1 35 onwards e User specifies a time period up to 255 seconds e wo wire host ensures that no more than 1 output may turn on and 1 output may turn off at any one time e This is followed by the stagger delay period during which no other outputs will be changed e This process is repeated until no further output changes are pending EE v2 pla Ns LA with no stagger delay T mE 2 074 Shift 1 1 2 3 4 i
3. Yes 0 32 0 Yes 0 Testing Capture Close 27 NMC 64 PRO Irrigation NETAFIM Enhanced two wire unit monitoring PoleNet now has support for the Two Wire Host s new System Capture feature To use this wait until the Monitor window shows that all the connected RTUS are available then click the Capture button Captured units are always listed and are considered as essential parts of the system Monitor window now has Totals at the top of the window showing from left to right e The number of Units displayed in the window he number of units with any outputs On e number of units Missing Lost or not yet found e he number of Extra units available but not captured or not defined a unit is defined if one or more of its lOs are explicitly mapped to 10 on the Host Controller if supported by the host interface eg NMC Colour coding has been added to highlight active outputs and any faults Green is used to show any active On outputs unless there is an error on the output in which case it will show the last known state in Red Red is used to show any faults such as the unit being lost or not yet found or an output being in the wrong state Blue is used to show any units which are not yet Captured or not yet Defined and helps locate problems with the system set up It identifies units which are connected Captured but whose 10 are not used Defined and units w
4. 36 CONTROLLER BUTTON TWO WIRE HOST 37 APPENDIX B VERSIONS amp FIRMWARE UPGRADES u cccccccccsscccccccccccccccccccccccccccscsccccccccccsscecoes 46 SOFTWARE 46 THIRD PARTY PRODUC WS EEEE AEE AEO EEEE OER ESES 46 RELATED DOCUMENTS 46 UPGRADING Z WIRE HOST secaccccsasavaecseenvavesecaneeeenesncadeaveueoibecunceuslwnwniediavayaciian aueessacsuaauvecbosteseeunasdenswunadbacavontewcaveepstavers 46 48 User amp Installation Manual Introduction Introduction The SingleNet system is a system that is designed to interface to various controllers and enable remote terminals The SingleNet system passes voltage and communication via a single 2 wire cable to a large number of Remote Terminal Units RTUs that can be widely spread throughout the field This manual describes in details all steps required to install and configure the SingleNet 2 Wire System Please read this manual fully before starting the installation 2 Wire System Control Modes The 2 wire system can be interfaced to one of four different types of controllers 1 NMC 64 PRO Controller 2 Parallel Controller any controller that generates 24VAC or 12VDC outputs 3 Elgal Irrigation control
5. SingleNet User Manual Application version e PoleNET V1 18 onwards 2 wire Host V1 38 onwards 2 Wire V1 16 onwards 64 V2 02 04 onwards e NMC Pro V3 00 01 onwards Date of issue 08 of February 2008 Publisher Netafim A C S Ltd Copyright 2003 Netafim No part of this publication may be reproduced stored in an automated data file or made public in any form or by any means whether electronic mechanical by photocopying recording or in any other manner without prior written permission of the publisher Although Netafim takes the greatest possible care both with its products and the associated manuals there may be deficiencies in them Netafim will not however accept responsibility for damage resulting from the use of Netafim products or damage resulting from the use of this manual Netafim also reserves the right to make changes and improvements to its products or to the associated manuals without notice Reproduced and edited with permission of Square One Laboratories Pty Ltd SingleNet 2 Wire System NETAFIM Table Of Contents INTRODUCTION 3 2 WIRE SYSTEM CONTROL MODES ccsececcsceccscecssceccscnccsceccscncsecsceecsceccecevsscecsscesesencescnseececeenscaccscersscersscecsseesesences 3 COMPONENTS IN THE 2 WIRE SYSTEM ccsccsceccecceccsccecescecceccscesceccecesceeceececescesceecsececescescescectsceecescsces
6. Os that have already been mapped to another Elgal input or output They are shown greyed out as in the 1 above 45 NMC 64 Irrigation NI E IM Appendix B Versions amp Firmware Upgrades This chapter details software and documentation versions and Soflware versions PoleNET software 1 18 onwards Two Wire Host 1 38 onwards Two wire RTU 1 16 onwards NMC 64 PRO V2 02 04 onwards NMC Pro V3 00 01 onwards Third Party Products Elgal Galileo Galileo 2000 OPN FLD E2 76 27616 Related Documents PoleNet Elgal Setup Commands and other information related to configuring the Elgal emulator in SmartPOLE microPOLE PoleNET User Manual User Manual describing all operation of the PoleNET software PoleNET 2 wire system opecification of the 2 wire host modbus interface Detailed Modbus Spec discussion of addresses is found here Upgrading 2 Wire host Please refer to the picture in the Appendix relevant to your system when following these instructions 46 NETAFIM Software Master Controller Relevant Appendix NMC NMC 64 PRO slave 2 Wire host Parallel Controller Parallel Controller mode Elgal controller mode Please follow these instructions completely and with great care The 2 Wire host module can be damaged beyond repair due to errors and omissions if these instructions are not followed 19 Disconnect power to the 2 Wire host module by removing the power connec
7. POLENET SOFTWARE CONFIGURATION MAIN MENU cccscecececcececececcecececececcecscecucescecscececescscecscusescscecuceseeescecs 16 SELECTING THE SYSTEM TO CONNECT TO sccsceccsceccececcsceccecececscsscscuscscaseececeecsceececececnecsceseecsseeceseececscsctsesceseeces 17 CONNECTING TO A SYSTEM cccccsccscoccsceccsceccsceccscsccscscscscascscascscasescssescssescsceecssescssscecseecasescesescssescsseecssescesscesenees 18 CONFIGURING 2 WIRE HOSTS cccsceccececcececcececcececcecececscececescscscescsececsseecsceecsceececsecscscecescscesescecescsceecssescsceseecusens 19 MONITORING 2 WIRE SYSTEMS cccscceccsccscecceccsccscesccceccscescecescsceecscescsceecesceecsetscescecescssesceecsscesescescescesescescascesencs 26 CONFIGURING 2 WIRE RT US 2 cc ccceccecceccscccccceccecescescuccsccecescecscceceeceecsecsceecescescsctecescescecsseecescescssescescscesencescens 31 MONITORING 2 WIRE ecccceccccecccceccecececcscescscescsceceececesceceecscccscsseecsececseeecseeecscaecscecscesescesescesescesencess 32 TESTING THE SYSTEM FOR PROPER OPERATION c cscescecesceccececescscescsceccscucesceccecuceecsceecscscsctscsceseecssescesescscescesescncess 33 APPENDIX A CONNECTING 2 WIRE HOST TO MASTER CONTROLLERS ee eee eeeeee 35 CONFIGURING TWO WIRE HOSTS cere ee ee eee eee eee eee eese sss
8. to cater for the NMC 64 PRO controller and other devices which may hold onto the RS 485 lines after sending commands or which may take some time to be ready for a response two wire host will wait for this brief time before responding to NMC 64 PRO commands The Tx delay should generally be left on 6 mS Only if it appears that the Two wire Host does not respond to the controller or the Host seems to send garbage or other controlled devices stop working when the Two wire Host is connected and the comms speed and parity are correct experiment with this parameter until the system works properly 20 User amp Installation Manual PoleNet Software Installation amp Operation Many errors are brief and transient by nature The 2 Wire host extends the life of errors so the NMC 64 PRO has sufficient time to observe the errors The Error Timeout determines how long errors are remembered remain active after the error condition ceases NMC 64 PRO Two wire Addressing Two wire RTUs have 2 outputs and 2 inputs so the Two wire Host supports up to 256 inputs and 256 outputs if all 128 two wire RTUs are connected The NMC 64 supports 64 outputs e g valves The NMC PRO supports 256 outputs e g valves and 32 digital inputs e g water meters The Two wire Addressing section selects the mapping technique to be used Mapping determines which two wire inputs and outputs are controlled by each of the NMC outputs and inputs Simple Linea
9. two valve outputs and two digital inputs e g to connect a water meter The internal view of an RTU is shown in figure Remote Terminal Unit Remote Terminal Unit The sections indicated are as follows A The 2 way connector is used to attach the RTU to the network the 2 wire cable B Two 3 way connectors are used to attach either two or three wire solenoids Two wire solenoids use only the red and black terminals leave the white terminal empty and three wire solenoids use all three terminals C Two voltage free contacts from water meters can be connected to this 4 way connector Input1 and Input2 are marked on the PCB D This RS 232 connector allows the RTU to be connected to a PC for configuration changes and firmware upgrades When attaching valves and water meters or any other input device these devices and their cables must be completely isolated from earth Figure Attaching RTU to the network shows how the 2 wire unit is attached to the 2 wire network 13 NMC 64 PRO NMC Pro Irrigation i NETAFIM 2 wire network mn LER Attaching an RTU to the network It is unimportant which wire in the cable is attached to which terminal as the RTU is able to operate either way Parallel Lightning Suppression Module PLSM The PLSM is a module that is attached to the RIU as shown in figure RIU with Parallel Lightning Protection Module RTU with Parallel Lightning Suppression Module The figure below illus
10. with stagger delay B t VL Shift 1 142 74 Shift 2 344 With stagger delay Shift 4 Shift Shift 2 Start Change Stop Monitoring 2 Wire Systems If you have not already done so 1 Set Connect To to Two wire Host in the Comms dialog see section Selecting the System to Connect to 2 Connect to the Two wire Host User amp Installation Manual PoleNet Software Installation amp Operation Monitor button 2 Wire host The Monitor button in the main menu opens the Two Wire Monitor window and starts displaying information about all connected RTUs All RTUs that are communicating with the host are displayed and sorted by their Unit ID The monitor window shows any RTU outputs that may be On Out1 and Out2 and it also displays the number of transitions changes of each of the RTU inputs In1 and In2 Two Wire Monitor Units 5 3 Missing 2 Extra 1 Test Capture Close If the host loses contact with an RTU it is removed from the monitor window until it is communicating again PoleNet keeps track of these drop outs and displays them in an extra column Drops of the monitor window This column is normally hidden from view to view it click the gt gt button in the bottom right corner Click the button to return to normal view Two Wire Monitor x Units 4 0 Missing 2 Extra 0 Dur Gute In Def Capt Avail Drops 0 0 0 ye No ves 0 2 0 O Yes
11. 5 D as explained below NMC 64 PRO communication card Connector J4 pin B Rx High row Connector J5 pin B Tx High row Connector J5 GND Com High row 2 Wire shielded cable Max distance 3 Meter i F i F E 2 Wire Host 2 Wire host 2 wire shielded cable Max distance 3 Meter Option A RS232 connections of 2 Wire host to NMC 64 PRO NMC 64 PRO NMC Pro Irrigation Option B RS232 Connection scheme with new type of 2 Wire host Use the prescribed special adapter cable to connect to connectors J6 as explained below 2 Wire host NMC 64 PRO communication card Connector J6 pin TXD Rx High row Connector J6 pin RXD Tx High row Connector J6 GND Com High row L 7 LI LI i inr uu i m oe ys E i OH ra i r 1 wi B as 502131 Li Lu 2 Wire host NMC Communication card 2 Wire host NMC 64 Pro Option B RS232 connections of 2 Wire host to NMC 64 PRO 10 User amp Installation Manual Hardware amp Connections RS485 connection The communication card must be RS 485x2 The NMC PRO controller is physically connected via RS485 to the 2 Wire host as shown in paragraph 2 Wire host RS485 connection use the prescribed special adapter cable to con
12. Hee ses E About About PoleNet and connected Unit 19 NMC 64 PRO Irrigation NETAFIM Config button 2 Wire host The Config button provides set up options relevant to the current 2 Wire host control mode If the 2 Wire host control mode is incorrect first use the Controller button to adjust it Each control mode has its own Configuration dialog the NMC 64 PRO configuration is detailed in the following sections For other control modes please refer to Appendix A Connecting 2 Wire host to Master controllers NMC 64 PRO Controller Configuration NMC 64 NMC PRO Interface Setup Controller t MMC B4 Cancel NME Id 1 1 247 Comms Info MH etwork RS485 Speed 9600 Parity None Ts Delay 0 50 ms Error Timeout 1g 10 600 secs T wa wire Addressing t Use Simple Linear Mapping Address 0 132 Offset Use Non Linear Mapping Setup The NMC 64 PRO Controller sends commands to one or more various devices to monitor their inputs and to control their outputs All devices need a unique NMC 64 PRO ID we recommend you use the default 1 for the Two wire Host although the value is only important if there are multiple devices connected to the NMC 64 PRO on a serial RS 485 Network The Comms Info must be set to suit the connection to the current NMC 64 PRO system Ideally specify the highest Speed if you have a choice The Tx Delay is provided
13. MC 64 PRO Mode This paragraph explains how to connect the 2 Wire host to the NMC In case you are using a different Master controller e g Parallel Elgal or PoleNet please refer to Appendix A Connecting 2 Wire host to Master controllers The NMC provides 64 outputs and 16 inputs that can be connected to use any of the RTU outputs and inputs NMC 64 PRO NMC Pro Irrigation NETAFIM If non linear mapping is enabled it is possible to control multiple RTU outputs with each of the 64 outputs from the NMC controller in effect providing up to 256 outputs The figure below 2 Wire host system in NMC 64 PRO Controller mode is a block diagram showing how the NMC 64 PRO controller interfaces to the 2 wire system Q SESRRERRRESRSERRSEESESSSEEREESSERSESEERSESERESESEEESSIREESSISESSRSERESREERSSREESESEEESSIEEEZEEERERESERSSSSESESESERZSERERESEEREENA Host unit 2 wire cable NMC 64 Pro Slave controller Controller 2 Wire host NMC 64 64 outputs NMC PRO 256 RS 232 outputs amp 32 inputs 2 Wire host system in NMC 64 PRO Controller mode User amp Installation Manual Hardware amp Connections Physical Connection The NMC 64 PRO controller is physically connected via RS232 or RS485 to the 2 Wire host as shown in paragraph 2 Wire host RS232 connection Option A RS232 Connection scheme with old type of 2 Wire host Use the prescribed special adapter cable to connect to connectors J4 C and J
14. NMC 64 PRO Irrigation NETAFIM When you have finished entering your settings return to the main menu and click the Connect button This will check that your Comms settings work and will then allow you to start interfacing with the target system Connecting to a System Before attempting to connect to a system ensure that there is a serial cable connecting the system to the PC and that the system is turned on Connect Disconnect button When you click on the Connect button PoleNet will attempt to communicate with the current system using the current comm port as specified in the Comms dialog see section Comms button Selecting the oystem to Connect to The clock symbol will spin during this lengthy process Establishing modem connection Querying unit If the Connect process is successful PoleNet returns to the main menu enables the main menu buttons and the Connect button changes its function to Disconnect The Disconnect button should only be used if you want to use the current comm port for some other purpose without exiting the PoleNet program While you are disconnected from a system most main menu buttons are disabled gt PoleNet Interface Two wire Host Comms Setup Communications Port Disconnect Connect Disconnect Unit Controller Select Two wire host control mode Cig Two Wire control mode specific configuration Advanced Advanced Settings Monitor Monitor Two tw
15. ber of outputs from 2 Wire RTUs Inputs can only be configured direct one to one For each NMC 64 PRO output or Input 1 Select the NMC 64 PRO Output or Input number that you wish to configure 2 If you wish give it a suitable Name describing its purpose and or location etc 3 PoleNet shows the RTU ports Activated Used by the NMC output input 4 PoleNet displays a list of Free RTU ports ones not allocated to the NMC 64 PRO 5 To allocate an RTU port to the NMC output input locate the desired RTU port in the Free list then either highlight it and click the Left arrow button or just double click it It then moves to the Activated Used list 23 NMC 64 PRO Irrigation NETAFIM For inputs you must first remove the mapping to an RTU input before you can replace it with another 6 Toremove an RTU output from the list of Outputs Activated by the NMC 64 PRO output locate the unwanted output then either highlight it and click the Right arrow button or just double click it It will move to the Free Outputs list If you cannot find a particular RTU output input in the relevant Free list then its RTU may not be detected at the moment turn off the Only Show Available Used Units option and see if the desired output input is now in the list If the RTU output input is still not in the Free list then it must already be allocated to a NMC 64 PRO address use the bottom Two Wire Outputs Inputs section to see how it
16. cescescesessescescesens 3 5 HARDWARE amp CONNEC TION S sescesesecseseosesesecsesesccsesececsesecsecsesesecsesessosesecsesesecsesessesesecsesesecsesesceseseseoseseseosesesees 6 SYSTEM STRUCTURE 2 W IRE HOST HERE 6 CONNECTION sede wale in 9 OPTION A RS232 CONNECTION SCHEME WITH OLD TYPE OF 2 WIRE HOST ceccscecceceecececcsceccsceceececscecescscusesces 9 OPTION B RS232 CONNECTION SCHEME WITH NEW TYPE OF 2 WIRE HOST ccsceccsceccsceccececcscecsececcscectscscusesces 10 R5455 CONNECTION 11 CONNECTING 2 WIRE HOST TO PC 12 SERIAL LIGHTNING SUPPRESSION MODULE 51 5 12 REMOT TERMINAL UNIT 13 PARALLEL LIGHTNING SUPPRESSION MODULE _5 14 ATTACHING WITH A PLSM TO NETWORK ecce eeeeeeee ee ee eee etes e eee ee ee eee se eese sess essesee esee ses esee 15 POLENET SOFTWARE INSTALLATION amp OPERATION cccccsccsccccccccccccccccccccccccccccccsccccccccccsscscces 16 INSTALLATION CM I M ea 16 UNUN TIN RR 16
17. e A T U 18 Close It is highly recommended not to change the pre empt value Monitoring 2 Wire RTUs If you have not already done so 1 Connect the 2 Wire RTU to the 2 Wire network 3 Set Connect To to Two wire RTU in the Comms dialog see section Selecting the System to Connect to 4 Connectto the Two wire RTU see section Connecting to a System Monitor button 2 Wire RTU The Monitor button in the main menu opens the 2 Wire RTU Monitor window and starts displaying information about the connected RTU 32 User amp Installation Manual PoleNet Software Installation amp Operation Monitor Two Wire ATU Line Charge Output 1 Charge Output 2 Input Count 1 Input Count 2 Output 1 Output 2 e Line Voltage is the voltage on the 2 Wire network e Charge Outputs are the voltages available for changing output state The RTU has to build up a charge of at least 13V before it can change output state e For each input the Input Count indicates the number of transitions changes of the relevant input e The state of both Outputs is also shown 1 for 0 for Off You can manually change test the outputs by clicking the relevant On or Off buttons After a period of inactivity PoleNet may lose contact with the RTU although this may not become evident until you attempt to change an output If so you will receive the following message polenet AN Connection lost
18. hich are Defined expected but don t exist or are faulty Black is used for normal operation 28 User amp Installation Manual PoleNet Software Installation amp Operation Test mode Test mode allows you to temporarily turn individual outputs on or off overriding the system controller It should only be used in the installation and testing process Normal operation is suspended while in Test mode 2 Wire host ignores all controller requests to change outputs state 1 Click the Test button to enter Test mode the button changes to display Testing to confirm and to remind you that you are in Test mode 2 While in Test mode right click on any RTU to see a pop up menu ut On lut Out On Off 3 Click on the desired action eg Out1 On Out1 Off etc 4 Wait for the command to be sent to the desired RTU for the RTU to turn the output on or off and for the two wire host to receive confirmation This will usually take about 10 seconds and will rarely require more than 30 seconds 5 To exit Test mode click the Testing button or the Close button 6 Two wire host returns to normal operation 10 seconds later Do not stay in Test mode unnecessarily Voltages button 2 Wire host The Voltages button in the main menu opens the Two Wire Voltage Monitor window and starts displaying Voltage and Current statistics for the 2 Wire network It reports the most recent value as well as the minimum a
19. iguration The top half of the dialog allows you to obtain pre existing parallel configurations and to then program them into the controller or save them for later use The lower half allows you to examine and modify the 37 NMC 64 PRO Irrigation NETAFIM parallel configuration You can either use the Parallel Inputs section to select the relevant outputs for each input or you can use the Two Wire Outputs section to select the relevant input for each output Configure Two Mire Parallel Interface Configuration File Demo_Parallel tet Load Save Read Program Parallel Inputs Input Number Mame input Outputs Activated Free Outputs Unit 5 2 Unit 13 1 Unit 16 2 M Only show AvailableUsed Units T ware Outputs Unit Number Out used Out 2 Alarm input Configuration File New removes all links between inputs and outputs although it retains the Name settings for the inputs Load allows you to fetch a previously Saved parallel configuration from the computer Save stores a copy of the parallel configuration onto the computer including all connections between inputs and outputs and the Name seitings for inputs Updating the Two wire Host Parallel Configuration Read fetches all the parallel settings directly from the two wire host You can then edit the settings and then save them or program them back into the two wire host N
20. ion of the dialog allows you to read the NMC 64 PRO mapping from the Host and to program them into the controller after editing You can also load pre existing NMC 64 PRO configurations from computer or save them for later use The lower half allows you to examine and modify the mapping of the NMC 64 PRO outputs and inputs There are two ways to configure NMC 64 PRO outputs Inputs to RTU outputs Inputs 1 Use the middle section NMC 64 PRO Outputs Inputs Select an NMC 64 PRO output Input you can also give it a name if desired and map it to a RTU output input from the Free Outputs Inputs list on the right see section NMC 64 PRO Outputs and Inputs 2 Use the bottom section Two Wire Outputs Inputs Select the unit number RTU no and configure a NMC 64 PRO output input to each or one of its outputs inputs see section Two Wire Outputs and Inputs 22 User amp Installation Manual PoleNet Software Installation amp Operation Updating the 2 Wire Host NMC 64 PRO Mapping Configuration Read fetches all the NMC 64 PRO mapping settings directly from the 2 Wire host You then edit the settings and save them or program them back into the 2 Wire host The two wire host does not keep track of the Names for NMC outputs inputs Program programs the current NMC 64 PRO mapping settings into the two wire host This takes several seconds so a Programming progress window is shown Configuration File New clears all mapping betwee
21. ire Units Inputs and Outputs Voltages Monitor Voltages on Two Wire Network About About and connected Unit 18 User amp Installation Manual PoleNet Software Installation amp Operation If the Two wire Host is not connected off line editing of the mapping is still supported for those control modes that use mapping Select the Controller type and the Cfg option will be available Configuring 2 Wire hosts Controller Click the Controller button from the main menu to access the Select Control Mode dialog box Select Control Mode Cancel Select the mode that applies for the system PoleNet queries the 2 Wire host to determine its current control mode and renames the Config button to suit the set mode The 2 Wire host can be interfaced to one of four different types of controllers 1 NMC 64 PRO controller 2 Parallel Controller 3 Modbus PLC Controller with Modbus capability 4 Elgal Irrigation controller Click the Controller button if you wish to verify or change the 2 Wire host control mode gt PoleNet Interface Two wire Host Lomm Setup Communications Port Disconnect Connect Disconnect Unit Controller Select Two wire host control mode Cig control made specific configuration Advanced Advanced Settings Monitor Monitor Units Inputs and Outputs Voltages Monitor Voltages on Two Wire Network Eur ghe S E LL
22. is allocated Two Wire Outputs and Inputs This section lets you view and setup the mapping from the 2 Wire Host s point of view as an alternative to the NMC 64 PRO based section above For each 2 Wire Unit 7 Select the 2 Wire RTU that you wish to configure from the Unit Number list 8 Ifa desired RTU is not in the Unit Number list then the RTU cannot be detected at the moment turn off Only Show Available Used Units to access it 9 PoleNet shows which NMC 64 PRO output is used for Out 1 and Out 2 10 To change choose the desired NMC 64 PRO port from the Out 1 or Out 2 lists 11 To free up an output input change its setting to Not Used The Not Used setting is the first item in the Out 1 and Out 2 In1 and In2 lists Advanced button 2 Wire host These advanced settings are critical settings and should not be changed by anyone not intimately acquainted with their effects These settings determine how the two wire host communicates with the two wire RTUs and also affect the amount of power that is available to the RTUs Danger Incorrect settings can have extremely serious negative consequences e Complete loss of communication with some or all RTUs e Intermittent breakdowns of communication e Intermittent operation of distant RTUs power failure inability to drive outputs 24 User amp Installation Manual PoleNet Software Installation amp Operation Advanced wo Wire Settings Comm Slot
23. ler 4 PLC Controller that supports Modbus driver Modbus Slave Mode The control mode is used to decide which of these controllers is the Master controller and can set read the state of system l O s Components in the 2 Wire System The 2 wire system consists of hardware and software The SingleNet PC software is called PoleNet and is used to install and configure the SingleNet 2 wire system as well as to analyze its behavior see PoleNet Software Installation amp Operation The hardware network consists of three main components as shown in figure Components in the 2 Wire network 2 wire cable Slave controller 2 Wire host RS 232 Master controller e g NMC 64 Pro To PC Components in the 2 Wire network SingleNet 2 Wire System NETAFIM Master Controller The master controller is the controller that decides the state of the I O s type depends the control mode of the system see 2 Wire System Control Modes Detailed descriptions of the different master controllers can be found in sections Connecting 2 Wire host to Master controller NMC Mode and Appendix A Connecting 2 Wire host to Master controllers Slave Controller 2 Wire host The slave controller 2 Wire host allows the master controller to access control the Remote Terminal Units RTUs The 2 wire host module communicates with the master via an RS232 where the master is NMC 64 Pro RS 485 cable or a separate connecto
24. n the NMC 64 PRO addresses and two wire RTUs but it retains the Name settings for the NMC 64 PRO outputs and inputs Load lets you fetch a previously Saved NMC 64 PRO configuration from the PC Save stores a copy of the NMC 64 PRO map configuration on the PC including the mapping of NMC addresses to RTUs ports and Names for NMC 64 PRO outputs amp inputs 2 Wire host supports 128 RTUs so the Free Units and Unit Number lists are very long To view only available units simply select Only Show Available Used Units PoleNet monitors the 2 Wire network to see which RTUs it detects and then only lists known RTUs This makes setup quicker easier and less prone to error but it requires the 2 Wire system and 2 Wire RTUs to be largely operational If you are setting up the NMC mapping before starting the system then you will not be able to use this option If a Unit is shown with brackets around it then that RTU cannot be found on the system at the moment but it has been mapped to the NMC 64 PRO This may help you find invalid settings although the RTU may have simply dropped out temporarily NMC 64 PRO Outputs and Inputs This section lets you view and setup the mapping from the NMC 64 PRO s point of view You can Name each NMC Output or Input which should make it easier to verify test and maintain the configuration Then you setup how each NMC 64 PRO output input maps to the 2 Wire system Each NMC 64 PRO output can control any num
25. n the PoleNet exe file and the software will open Uninstalling To uninstall PoleNet simply erase the PoleNet exe file PoleNet software configuration Main Menu When PoleNet software is started the main menu should appear al PoleNet Interface Two wire Host Setup Communications Fort Connect Connect Disconnect Unit About About PoleNet and connected Unit The heading shows which system PoleNet is set up to interface to Two wire Host in the figure above Most buttons are disabled until PoleNet starts interfacing with a system The functions of these buttons vary to suit the current application 16 User amp Installation Manual PoleNet Software Installation amp Operation Click the Comms button to set communication settings See section Selecting the System to Connect to After setting the correct COM port and system click the Connect button to start interfacing to the system See section Connecting to a System After the system has connected successfully all relevant buttons will be enabled In case the system does not connect try checking you connections and COM port definitions Selecting the System to Connect to Comms button PoleNet can connect to the following systems devices via a PC serial comms port e wo Wire Host e wo Wire Once the connection is established using the Connect button from the main menu see section Connecting to a System PoleNet will provide an interface to the s
26. nd maximum values Two Wire Yoltage Monitor Output Voltage V Min 20 064 Latest 28 228 20 992 Output Current rv 35 Latest 39 50 Return Voltage V D 2 zr Latest 3 754 Clear E 29 NMC 64 PRO Irrigation NETAFIM e Output Voltage is the voltage provided by the Host to the two wire network e Output Current indicates the drain load imposed by the RTUs and the wiring e Return Voltage indicates the strength of communications returning from the To restart the minimum and maximum statistics simply click the Clear button diagnostic features such as the Errors display in the Two Wire PAT PoleNet version V1 26 onwards has some additional system J Voltage Monitor screen refer Figure below Two Wire Voltage Monitor Output Voltage 28 429 Latest 28 992 Max Output Current m Min oe Latest 39 46 Mean 40 Peak He Return Voltage 1 046 Latest 3 566 Max 4 862 Errors Over Current e The Error display window will report major system errors as reported by the host unit Please refer to Table below for a list of errors and their descriptions Over Current Excessive two wire current Possible short circuit Two wire voltage is very low in danger of failing Two wire voltage has failed reserved S Wi wi 5 L8 7 Missi 8 30 User amp Installation Manual PoleNet Soft
27. nect to connector J5 as explained below Connector J5 pin A A2 High row Connector J5 pin B B2 High row Connector J5 GND GND High row ter 509 pit b ad rcm ai i FEM CA wem pine ee a x 5 o gt n y GI emn f im i 2 Wire Host 2 Wire host NMC Pro RS485 connection of 2 wire host to NMC 64 PRO 11 NMC 64 PRO NMC Pro Irrigation Connecting 2 Wire host to PC The 2 Wire host module consists of a serial interface so it is possible to make configuration changes and to monitor activities of the 2 Wire host from a PC Using a RS 232 cable plug one end of the RS 232 cable into a PC COM port and the other end into connector J7 B shown in paragraph 2 Wire host Configuring and Testing should be done using the dedicated PoleNet program Serial Lightning Suppression Module SLSM As mentioned earlier the SLSM can be used to provide improved protection to the 2 Wire host module from high voltages generated by lightning strikes see figure Serial Lightning Protection Module The SLSM unit is fitted between the host unit and the two wire network cable as illustrated in figure Connecting the SLSM Host unit 2 wire network 2 wire connector Earth Connecting the SLSM 12 User amp Installation Manual Hardware amp Connections Remote Terminal Unit RTU The Remote Terminal Unit consists of
28. oftware setting of this port should still be RS485 LK1 amp LK2 for switching host communications port 2 from RS 485 on J5 to RS 232 on J6 when both are down RS 485 when links plugged between the top and centre pins and RS 232 between bottom and centre pins G J5 connector is a RS 485 socket to plug in Master controller U27 regulator Before inserting removing the programming link see J below touch the tab on the right to discharge any personal static electricity to prevent permanent damage to the 2 Wire host LED 1 Red flashes with error code during fault conditions User amp Installation Manual Hardware amp Connections LED 2 Green flashes slowly during normal operation J J1 Connector for attaching the programming link for firmware updates see H above K J2 connector for attaching to the 2 wire network and to the protective earth 2 Wire Host shown in figure above includes battery backup optional Connecting power to 2 Wire host Power is supplied to the 2 Wire host by the connector labeled J3 A Remember to disconnect the power connector when the unit is not in use in order to avoid damaging the battery Connecting 2 Wire host to RTUs The 2 Wire host is connected to the RTUs by the connector labeled J2 F Figure 1 shows how the cable is to be connected 2 Wire cable 2 wire connector Earth Figure 1 Connecting the 2 wire cable Connecting 2 Wire host to Master controller N
29. ost Elgal Configuration Read fetches all the Elgal settings directly from the two wire host You can then edit the settings and then save them or program them back into the two wire host Program causes the current Elgal settings to be programmed into the two wire host 42 User amp Installation Manual Appendix A Both the Read and the Program can take many seconds so a suitable progress window is shown while you wait Card Definitions The Card Definitions section allows you to view and change the Elgal cards emulated by the Two wire Host along with the mapping of Elgal cards I O to Two wire RTUs The Two wire Host can support up to 8 Elgal cards of various types e Digital24 with 24 relay outputs e Digital with 16 relay outputs and 8 digital inputs CRTU with 64 RTU units each with 2 digital outputs and 4 digital inputs Click on symbols to view mapping details Click on symbols to close them up Right click on any item for a pop up menu with a choice of available actions The actual mapping of Elgal address to Two wire network address is shown for each Elgal l O Unmapped Elgal I Os are shown as In the figure below the line 3 3 0 2W1 5 2 indicates that the function of Elgal card 3 a CRTU card Unit 3 digital output O is mapped to implemented by Two wire network 1 RTU 5 digital output 2 In order to ensure that the Elgal controller can correctly communicate with the 2
30. ote the two wire host does not keep track of the Name settings for inputs Program causes the current parallel settings to be programmed into the two wire host This takes several seconds so a Programming progress window is shown 38 User amp Installation Manual Appendix A Two wire host systems support up to 128 two wire RTUs so the lists of Free Outputs and Unit Numbers are very long If you use the Only Show Available Used Units option then PoleNET monitors the two wire network to keep track of all the RTUs that it detects and adjusts the outputs lists to only include Known RTUs This makes the setup quicker easier and less prone to error but it requires the two wire system and all two wire RTUs to be largely operational lf you are setting up the parallel interface before starting the system then you will not be able to use this option If an Outputs list includes a Unit with brackets around it then that RTU cannot be found on the system even though it has been allocated This can help you find invalid settings although the RTU may have simply dropped out temporarily Parallel Inputs The Parallel Inputs section allows you to view the outputs activated by each of the 48 available parallel inputs and to change their allocation Each input can be connected to any number of outputs from two wire RTUs Each two wire RTU output must be controlled by only one parallel input PoleNET allows you to give each input a Name
31. r where the master is a parallel controller card The 2 Wire host can also be connected to a PC via a RS 232 cable for installation and testing purposes Remote Terminal Units RTUs The RTUs are low powered devices each consisting of two digital inputs and two digital DC latch outputs These units interface to the 2 Wire host module via a single 2 Wired cable Optional Components There are two other optional components that the system can consist of A Serial Lightning Suppression Module SLSM and one or more Parallel Lightning Suppression Modules PLSMs The SLSM and the PLSMs provide improved suppression of high voltages generated by lightning strikes in the vicinity of the 2 wire host module and the RTUs respectively User amp Installation Manual Getting Started Getting Started This paragraph briefly explains how to get started with the SingleNet system For further explanations please see the detailed instructions per section Start with the physical connections for initial setup of the system Later steps might depend on earlier ones therefore it is essential to go through all the steps The following chart may be used for assistance Table description Hardware amp Connections 2 Wire host Follow the 2 Wire host sections for connecting the 2 Wire host Connecting power to 2 Wire host Connecting 2 Wire host to RTUs Connecting 2 Wire host to Master controller Connecting 2 Wire host to PC If existen
32. r Mapping is very straightforward it simply allocates a continuous block of 64 2 Wire outputs and corresponding inputs so there is a 1 1 correlation to the NMC outputs and inputs Eg If you are using the first 32 RTUs Address Offset 0 then NMC 64 PRO address 1 two wire Unit 1 port 1 NMC 64 PRO address 2 two wire Unit 1 port 2 NMC 64 PRO address 3 two wire Unit 2 port 1 NMC 64 PRO address 4 two wire Unit 2 port 2 NMC 64 PRO address 5 two wire Unit 3 port 1 etc You can map to a different set of two wire RTUs by using the Address Offset a value of 2 moves the NMC 64 PRO up by 1 RTU 2 outputs NMC 64 PRO 1 Unit 2 port 1 We recommend you don t use an odd numbered Address Offset for the NMC 64 since the 64 NMC addresses will then map across 33 RTUs only using half of the first and last RTUs Use Address Offset 0 for the NMC PRO otherwise you will not be able to use all the NMC outputs There is also merit In setting the Address Offset ID of first two wire Unit 1 2 because NMC address 1 will then correspond with the first two wire port however if you later add two wire units with lower IDs you will have to change the Address Offset which will then require reprogramming the Host NMC 64 PRO Non Linear Address Mapping Use Non Linear Mapping is used to enable more flexibility or if you would like NMC 64 PRO outputs to be able to control more than one two wire output each This is also a very u
33. s 64 164 Comm Bit Width 92 182 Close Clear Inputs after 2 2 60 minutes absent for IW Stagger Outputs Every 10 seconds The 2 wire system provides power and serial communications on the same two wires RTUs extract power from the 2 Wire network and wait for communications targeted at them and communicate with the Host only when asked The power available to RTUs is decreased e By the number of other RTUs sharing the same two wires e By distance from the host due to losses in the wires and from closer RTUs e While there is communication on the 2 Wire network There is usually little that can be done to change the location and hence the distance of RTUs but you may be able to site the 2 Wire host in a central location and have multiple two wire runs radiating out in a star pattern from the host Once all RTUs are installed the communication parameters must be set to ensure they all receive adequate power and have reliable communications to and from the host Comm Slots is simply the number of communications slots per second Increasing this number speeds up the rate of communications reducing the average response time of the system but it may make the communications unreliable and it reduces the amount of power available for distant RTUs The bracketed value 64 is the standard setting Comm Bit Width is the duration in microseconds of each serial bit The bracketed value 82 is the standard setting
34. s and to change the allocations For outputs from each two wire unit 1 Select the Two Wire that you wish to configure from the Unit Number list 2 If you cannot find a particular output in the Unit Number list then the RTU cannot not be detected at the moment turn off the Only Show Available Used Units option and access the unit in the list PoleNET will show which parallel inputs are used for the Unit s Out 1 and Out 2 4 change simply select a different parallel input from the Out 1 or Out 2 lists 5 up an output change its allocation to lt Not Used The Not Used setting is the first item in the Out 1 and Out 2 lists Elgal controller mode 2 Wire System Controller in Elgal Slave Mode a a ic Ly E E m RI T 58 E Y amp 1 E D The Indicated sections J3 connector providing power to the 2 wire host 40 User amp Installation Manual Appendix A J7 connector is a RS 232 socket to plug in cable to connect a PC Used for setup and diagnostics C J2 connector for connecting the 2 wire cable to the RTUs D J5 connector is a RS 485 socket to plug to Elgal master ensure correct polarity and grounding Note Requires optional Elgal connecting cable kit E J1 programming Link Controller shown with optional battery backup Host unit Slave controller 2
35. see section Software versions If you are not able to operate the system contact an authorized Netafim dealer 34 User amp Installation Manual Appendix A Appendix A Connecting 2 Wire host to Master controllers Parallel Controller mode This section describes how to use the Parallel Controller card as the controlling device of 2 Wire host see the figure bellow In this mode it is possible to control one or more outputs of the 2 wire network using a single 24V AC or 12V DC digital input There are 48 inputs available in the controller 2 Wire System Controller in Parallel Controller mode i A i L 1 35 NMC 64 PRO Irrigation NETAFIM The Indicated sections are A Connector providing power to the 2 Wire host B J7 connector is a RS 232 socket to plug in cable to connect a PC Used for setup and diagnostics C J2 connector for connecting the 2 wire cable to the RTUs D Inputs of the Parallel Controller Board E J1 programming Link Controller shown with optional battery backup Figure 2 Wire host in parallel Controller mode is a block diagram of how the parallel controller interfaces to the 2 wire system Host unit 2 wire cable Parallel Controller Slave controller module 2 Wire host 1 RTU 3 48 x digital inputs To PC 2 Wire host system in Parallel Controller mode Physical Connection The system is generally shipped wi
36. seful system because you can change the mapping of one NMC 64 PRO address without affecting the mapping of any other NMC addresses this lets you use the NMC 64 PRO to control amp monitor different crops or fields at different times without interrupting or changing the setup for the main part of your system Click the Setup button to configure the non linear mapping 21 NMC 64 PRO Irrigation NETAFIM Each NMC 64 PRO output can be mapped to any number of outputs from 2 Wire RTUs but each 2 Wire RTU output must be controlled by only one NMC 64 PRO output Configure NMC 64 Address Mapping Read Program Configuration File Hew Load Save Configure Address Mapping Read Program Configuration File Demo Hew Load Save Setup Outputs Setup Inputs Only show Available Used Units Inputs Input Mame 28 NMC 54 Input 26 Input Used Unit 14 2 Setup Outputs Setup Inputs M Only show AvailableUsed Units Outputs Output NMC 54 Output 4 Outputs Act ated Unit 13 2 Unit 15 2 Free Outputs Free Inputs Tivo ire Outputs Unit Number ue 15 Out 2 NMC 64 Output 5 T wa wre Inputs Unit Number NMC 64 Input 23 16 2 NMC 64 Input 25 The top sect
37. t connect the Serial Lighting Suppression Module Connect the RTUs to the SingleNet network and to the I O devices If existent connect the Parallel Lighting Suppression Modules PoleNet Software Installation amp Operation installation configuration Main Menu Connect to port Connecting to a System Check that you are able to connect to the 2 Wire host Configuring 2 Wire hosts Select the Master Controller Mode and configure the connection between the Master controller and the 2 Wire host Testing the systems operation Testing the system for Follow the instructions to verify that the system NMC and SingleNet is proper operation working properly NMC 64 PRO NMC Pro Irrigation i NETAFIM Hardware amp Connections System structure Miro Elect Card y ees EET a E 3 o l TAL M KALE 5 1 LE E AJ CE m mk sum afl Pai P m 2 I Pus J OQO The indicated components are A B J3 connector providing power to the 2 wire host J4 connector is an Auxiliary RS 485 socket also for compatibility with old style RS 232 Master controller connection mode J7 connector is a RS 232 socket to plug in cable to connect a PC Used for setup and diagnostics LED 3 Red flashes when input power at J3 is present J6 connector is a RS 232 socket to plug in Master controller note that s
38. th the parallel controller board plugged in to the 2 Wire host module The Parallel Connector inputs are labeled D in paragraph Parallel Controller mode Every 24 inputs have a common connector and should be connected to the outputs of the Master controller Configuring Two wire Hosts If you have not already done so 36 User amp Installation Manual Appendix A 1 Set Connect To to Two wire Host in the Comms dialog see section 0 2 Connect to the Two wire Host see section 0 gt PoleNet Interface Two wire Host Corrs Setup Communications Port Disconnect Connect Disconnect Unit Controller Select Two wire host control mode Cig ParEtrl control made specific configuration Advanced Advanced Two Wire Settings Monitor Monitor Two twire Units Inputs and Outputs voltages Monitor Valtages on Two Wire Network 93334 About About PoleNet and connected Unit PoleNET quesries the Two wire host to determine its current control mode and renames the Config button to suit Click the Controller button if you wish to verify or change the Two wire host control mode Controller button Two wire Host Click the Controller button from the main menu to access the Control Mode dialog Select Control Mode Parallel Controller Cancel Then select the mode that applies for the system PoleNET will adjust the text on the Config button in the main menu to suit the control mode Parallel Controller Conf
39. tor J3 A 20 Connect the PC to the 2 Wire host module using a RS 232 cable connected to connector J7 B 21 Touch the aluminum tab of the regulator U27 in with your finger to discharge any static electricity that may have built up on your body This is a critical step Failure to comply can render 2 Wire host inoperable 22 Place the programming link on the programming jumper J1 LNK see section 2 Wire host as shown in figure Placing the programming link programming link programming jumper Placing the programming link 47 NMC 64 Irrigation NE TA FIM 23 Reconnect power to the 2 Wire host module 24 Execute the upgrade program from the PC gt W25127 port 127 is the version of the upgrade 25 Disconnect power to the module 26 Again touch the aluminum tab of the regulator as in step 3 27 Remove programming link 28 Reconnect power This completes the 2 Wire host firmware upgrade Upgrading RTUs 29 In order to upgrade the software connect an RS 232 cable from your PC COM port to the RS 232 socket in the RTU Connector D in figure Remote Terminal Unit 30 Execute the provided upgrade program from your PC gt W2SRTU_v116 coml load version 1 16 from com1 This completes the RTU firmware upgrad 48
40. trates how to attach an RTU with a PLSM to the network 14 User amp Installation Manual Hardware amp Connections 2 wire network Attaching RTU with a PLSM to network It is important to note that if a PLSM is used the 2 way connector of the RTU labeled A in Remote Terminal Unit RTU section itself must not be connected The number of these units RTU PLSM that are required depends on how susceptible the area is to lightning If the severity is low PLSMs can be placed for example 10 units apart whereas if the area is more prone to lightning every unit may have a PLSM attached see figure Example of placing units with PLSMs Low susceptibility to lightning High susceptibility AX to lightning Unit with PLSM Example of placing units with PLSMs 15 NMC 64 PRO Irrigation NETAFIM PoleNet Software Installation amp Operation PoleNet software is the interface where the technician defines the Irrigation controller which communicates with the SingleNet 2 Wire Host and operates the field valves via the SingleNet RTUs PoleNet software is used for SingleNet system Configuration Setup Test and Monitor PoleNet software features e Test communication with field units Test outputs and inputs e Program load and backup your configuration files online or offline e Communication diagnostics e HTU ID programming Installation PoleNet software does not require installation simply double click o
41. ware Installation amp Operation About button The About button reports the current version of the PoleNet software and the current software version of any connected Units Two wire Host in the figure below About PoleNET x PoleNet Version 1 26 Copyright 2002 2007 Square Laboratories Twa wire Host version v1 38 Configuring 2 Wire RTUs If you have not already done so 1 Set Connect To to Two wire RTU in the Comms dialog see section Selecting the System to Connect to 2 Connectto the Two wire RTU see section Connecting to a System zi PoleNet Interface Two wire Comms Setup Communications Port Disconnect Connect Disconnect Unit Setup Setup Two wire RTL Monitor Monitor ATU Voltages Inputs and About About PoleNet and connected Unit The heading shows that PoleNet is set up to interface to Two wire RTU and only relevant buttons are enabled Setup button 2 Wire RTU 31 NMC 64 PRO Irrigation NETAFIM When you click on the Setup button in the main menu a progress window will be displayed while PoleNet reads the RTU configuration Reading ATU configuration In a 2 Wire network every unit must have a unique ID from 0 127 They are pre programmed with consecutive IDs during manufacture so this is seldom an issue Pre empt fine tunes the RTU s comms handler it is set by default to 18 Setup Two Wir
42. which should make it easier to verify test and maintain the configuration For each parallel input Select the parallel Input Number that you wish to configure If you wish give it a suitable Name describing its purpose and or location etc PoleNET displays a list of the Outputs Activated when the input becomes active PoleNET displays a list of Free Outputs outputs not yet allocated to any input To make the input activate another output locate the desired output in the Free Outputs list then either highlight it and click the Left arrow button or just double click the desired output It will move to the Outputs Activated list 6 To remove an output from the list of Outputs Activated by the input locate the unwanted output then either highlight it and click the Right arrow button or just double click the unwanted output It will become a Free Output pum Dope If you cannot find a particular output in the list of Free Outputs then the output s RTU may not be detected at the moment turn off the Only Show Available Used Units option and see if the output is now in the list If the output is still not in the Free Outputs list then it must be allocated to another input use the Two Wire Outputs section to see which input it has been allocated to 39 NMC 64 PRO Irrigation 4 NETAFIM Two Wire Outputs The Two Wire Outputs section allows you to view which parallel input controls each of the outputs from two wire RTU
43. wire host RS232 2 wire cable Elgal Controller To PC Figure 2 2 Wire host controlled by Elgal Physical Connections The Elgal controller is physically connected via RS485 to the 2 Wire host using connector D as shown in Elgal controller Ensure the RS485 connection to the Controller observes correct polarity and provides proper ground connection between the units When you enter the Elgal Configuration screen PoleNET automatically reads the current Elgal configuration from the Two wire Host This process takes several seconds so a progress screen is displayed while the Host is read The top half of the dialog allows you to obtain pre existing Elgal configurations and to then program them into the controller or save them for later use The lower half allows you to examine and modify the Elgal configuration 41 NMC 64 PRO Irrigation NETAFIM Configure Elgal Cards Enable Egal Configuration File Demo_Elgal te Load Save Read Program Lard Definitions lt 0 empty Show Card 1 digital H Card 2 digital24 E Card 3 z Card 4 empty z Card 5 empty 6 empty Card F empty Configuration File New deletes all cards and all settings Load allows you to fetch a previously Saved Elgal configuration from the computer Save stores a copy of the Elgal configuration onto the computer Updating the Two wire H
44. wire system it must be configures with exactly the same card types in exactly the same slots as the two wire host 43 NMC 64 PRO Irrigation Configure Elgal Cards Enable Demo code _ empty m TS digital Card 3 crtu p Unit 0 E Unit 1 E Unit 2 Unit 3 tudo 000 32M0 PW 5 2 000 3 31 PW B02 rtudi z acr ees 8 3 1 Zw 5 2 2 3 2 foe 3 3 3 PW TOF To change an Elgal card right click on the relevant card to access a pop up menu as shown above Each pop up item is detailed on the next page Change Type replaces the current card with a different type of Elgal card Change Card 2 digital24 type x 44 User amp Installation Manual Appendix A Delete removes the current Elgal card replaces it with empty polenet Delete digital24 card in Slot 2 Are you sure Move allows you to move a card to a different position retaining its network settings Clear removes all the Two wire RTU network allocations from the card polenet 9 Clear settings of digitale card in Slat 2 Are you sure To change a specific Elgal I O mapping eg 3 3 1 2W1 30 2 right click it and select Edit PoleNET will display the current setting Edit rtudo port 3 3 1 Network C H PoleNET lists all possible RTU Units whether or not they are connected to the two wire host PoleNET will not allow you to select RTU l
45. ystem device and enable to access the system s settings and monitor the system s status To select the system to connect to click the Comms button from the main menu This will open the Comms Config screen Comms Config x Connect Two wire Host Port Use Modem Connection Lancel Commi Comm Modern Configuration t Comm2 Comme Phone t Comm Init String Comm Comm 8 Inactivity Timeout seconds 300 e Connect To choose the system that PoleNet should interface to from the list of options e Port choose which serial RS 232 Comm Port you wish to use to connect to the system Most PCs do not provide connections for more than two comm ports as standard PoleNET v1 21 onwards also supports COM5 8 to support users who add comm port cards to their computers e Modem Configuration this section allows you to connect to an off site target system using a modem This option is only available if you mark the Use Modem Connection check box e Phone No type in the phone number of the off site target system s modem String if required enter an initialization string for your modem It may be necessary to configure your modem to suit the target system s modem or to disable your call waiting e Inactivity Timeout specify an inactivity timeout in seconds to avoid tying up either phone line e Port specify the serial port connected to your modem 17